Chennai Metropolitan Water Supply And Sewerage Board Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Chennai Metropolitan Water Supply And Sewerage Board - CMWSSB Tender
Eprocure
Opening Date24 Nov 2020
Closing Date14 Dec 2020
Tender AmountRefer Documents
Costs
EMD
₹ 1,12,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_CMWSS_185911_1Bid Award Id
ViewTender No
CNT/WSS/SDRF/3197B/2020-21Tender Authority
Chennai Metropolitan Water Supply And Sewerage Board ViewPurchaser Address
-Website
http://https://chennaimetrowater.tn.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply, delivery, erection, testing and commissioning of 1010 KVA / 3.3. KV HT DG set including construction of DG room and allied works in Raw water pump house at Sethiathope in Veeranam for providing uninterrupted water supply to Chennai city
BOQ Items
1.5m - 4.5m below GL
11
-
-
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement concrete structural elements under controlled water cement ratio with plasticiser using 20mm and down graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the Board officers complete.
-
-
-
(i) Upto 1.5m (upto Plinth level) above and below GL
44
-
-
ii) Ground floor (1.5 to 4.5m)
29
-
-
Supplying, fabricating and laying in position M.S. rounds or RTS rods for RCC works including cost of reinforcement, binding wire, cutting, bending, cranking and tying in position with binding wire etc. complete
7400
-
-
Providing formwork with centering for soffits of reinforced cement concrete slabs or plain surface including strutting upto 3.0m high etc complete
I) upto 3m high
197
-
-
II) Above 3m high
261
-
-
Sun shade laying CC 1:2:4 for RCC sun shade works using 20mm BG jelly 100mm thick at wall end and 80mm thick at free end and projecting 900mm from the wall face moulded along with RC lintels and tiled into the full thickness of wall where there are no lintels excluding cost of reinforcement but including centering, shuttering, compacting, curing and finishing etc. complete.
26
-
-
Stock brick work in cement mortar 1:4 using second class bricks including curing etc. complete for 23 cm thick wall
-
-
-
upto 1.5m from G.L.
16
-
-
Ground floor
50
-
-
Grnolithic flooring 50mm thick with CC 1:2:4 using 3-10mm chips and top surface rendered smooth with cement including thread lining 25mm dia GI pipe of necessary length for water outlet curing, etc. complete.
120
-
-
Paving hydraulic pressed cement mosaic tiles of approved colour and of size 20cm x 20cm x 20mm finished thickness with small verona of indian marble chips (other than Salem magnesite) with cement mortar 1:3 - 20mm thick and pointed with the same coloured cement including polishing with power polisher, to a high degree of polish so as to be perfectly smooth and glossy with grey colour mosaic tiles
120
-
-
Flooring rendered smooth with 10kg / 10sq.mtr. Of cement including etc., complete
90
-
-
Plastering with C.M 1:3 for 20 mm thick including curing etc. complete
560
-
-
Special ceiling plastering 10mm thick with C.M. 1:3 for RCC slabs and beams including hacking and curing etc., complete.
110
-
-
Weathering course concrete with broken brick jelly 20mm guage in pure slacked lime over RCC roof slab in proportion of 32:12 1/2 (no sand to be used) well beaten with wooden beaters to the required depth of 80mm thick and giving required slope and thickness to roof as required etc. complete.
13
-
-
Terrace flooring with two course of flat tiles of 15cm x 15cm x 12 mm using cement mortar 1:3 mixed with crude oil 10% by weight of cement and pointed with same oiled mortar
102
-
-
Supplying and erecting rolling shutters of 76mm, 18gauge of galvanised steel sheet with push and pull or self coiling type operated by pulling hook with top cover including locking arrangements and fixed in position inside or outside etc., complete and painting with priming coat of red oxide without lock (payment will be made only for actual opening of the shutters when rolled up wherever the shutters are to be fixed)
18
-
-
Aluminium openable type window size 1.2m x 1.3m : Maufacturing supplying and fixing in position Anodised Alu. Natural colour mat finish with openable type window with extruded Alu. Sections with two panels of size (Frame - 38 x 33 x21 x 2.4mm @ 0.615 Kg/m, Shutter: Bottom, Top - 38.5 x 33 x 24.5 x 3 & 4mm @ 0.706 Kg/m, Interlocking vertical - 59 x 33 x 25 x 2.5mm @ 1.135 Kg/m) with necessary accessaries such as rubber beadings best quality of lock handle hinges,stays and fixing 4 mm thick plain / frosted/ pin headed glass including cost of all materials labour for electrical consumption required for drilling holes in RCC columns, beams, masonry wherever necessary with power drill to the extent required and made good to the original conditions after fixing as directed by the Board officers.The Al.Surfaces is to be anodised with matt finish usder electrically condition in accordance with ISI1868/1962 specification for an average anodic film thick of not less than 15 microns. (All materials should be got approved by the Site Engineer before fixing in position)
8
-
-
Supplying and fixing M.S. grills for window and gate including one coat of primer with red lead etc. complete as directed.
50
-
-
Supplying and fixing in position of aluminium anodised colour matt finish Louvered Ventilator. The outer frame will be 62x38x2mm @ 1.17 Kg / m and the louvers with moving arrangements will be made with Alu. Channel of size 60x30x4 mm @ 1.27 kg /m with necessary glass pans for louvers 4mm thick Al. Clips, including all materials, labour & power consumption charges required for fabrication if necessary chipping dismantling making holes in RCC columns,beams or masonry wherever necessary with power drill to the extent required and make good to the original conditions after fixing etc., complete. The Aluminium surface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 of anodic film thickness of not less than15 microns (fifteen) for all sections. All the materials should be got approved by the Site Engineer before fixing in position as directed.
3
-
-
white washing one coat (plastering area for inner and ouer walls includung ceiling)
660
-
-
Colour washing two coats with approved cement paint over one coat of cement paint including cleaning, preparing the surface, curing etc., complete.
660
-
-
White washing three coats.
110
-
-
Painting with superior quality ready mixed paint of chocolate, light green grey or any other approved colour for new iron works two coats
18
-
-
Refilling with excavated soil (other than sand) compling with standard specification for filling in foundation and basement etc. complete.
70
-
-
Disposal of surplus earth including loading, unloading and carting to the place as directed at site etc complete.
30
-
-
Supplying and fixing of 12” sweep AC exhaust fan complete
8
-
-
Providing and fixing 100mm dia AC down fall pipe
25
-
-
Supply delivery erection testing and commissioning of 1010KVA / 3.3KV HT DG set CPCB-II compliant with Auto start stop controller , Prime rating, radiator cooled with Micro Processor based controller, Residential Silencer, Anti vibration mountings,exhaust flexible connectors, Batteries with cable including Accoustic enclosure and other accessories complete inside Raw water Pump house at Sethiathope including incidental Civil works etc. complete as per site conditions
1
-
-
Supply delivery erection testing and commissioining of 630Amps VCB Breaker panel with indication lamp, Volt and Ammeters, Master trip relay etc as required complete for receiving the supply from the Alternator of 1010KVA 3.3KV DG set including necessary Foundation channels, supports and incidental Civil works etc. complete as per site conditions
1
-
-
Supply delivery Erection testing and commissioining of HT Relay, metering and protection panel suitable for 1010KVA / 3.3KV DG set including necessary Foundation channels, supports and incidental Civil works etc. complete as per site conditions
1
-
-
Supply delivery Erection testing and commissioining of Neutral Ground resistor with Neutral Vaccum switch panel for 1010KVA 3.3KV DG sets including necessary Foundation channels, supports and incidental Civil works etc. complete as per site conditions
1
-
-
Supply delivery Erection testing and commissioining Dynamic Compensator Panel suitable for 1010KVA 3.3KV DG sets including necessary Foundation channels, supports and incidental Civil works etc. complete as per site conditions
1
-
-
Supply delivery Erection testing and commissioining of 630Amps VCB Breaker panel with necessary Current Transformers, Potential Transformer, Spout assembly, Isolating contacts, shutter, 630A Interuppters, PT fuses, Power pack, Protection Relays, metering instruments, control circuits, indication lamp, Volt and Ammeters, Master trip relay etc as required complete breaker panel for 1010KVA 3.3KV DG set to receive DG supply in the pumphouse with necessary fixing arrangements and incidental civil worls etc. complete as per site conditions
1
-
-
Interconnection of the new DG VCB panel with the existing HT panel with necessary bus bars as per site condition including fabrication works, Mechanical interlocking etc., complete as per site conditions
1
-
-
Supply and laying of 3Core X 240sqmm 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for 1sec) cores laid up, inner sheathed of PVC tape, galvanized steel falt strip armoured and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments and laying in a trench to be excavated at a depth of 2 1/2" putting 6"layer of sand including power drilling of TAR road and covering the cable with brick, cement truff and sand refilling the earth to make good.
180
-
-
Providing HT 3Cx240sqmm end termination kit with socket and necessary insulation materials etc., complete
4
-
-
Supply and laying of the following sizes of 1100V PVC insulated Copper Armoured cable
-
-
-
4 Core 1.5 Sq.mm
300
-
-
4 Core 2.5 Sq.mm
275
-
-
24 Core 1.5 Sq.mm
300
-
-
2 Core 1.5 Sq.mm
300
-
-
End termination of the following sizes of 1100V PVC insulated Copper Armoured cable above control Cable
-
-
-
4 Core 1.5 Sq.mm
2
-
-
4 Core 2.5 Sq.mm
2
-
-
24 Core 1.5 Sq.mm
2
-
-
2 Core 1.5 Sq.mm
2
-
-
Earthing as per the ISI specifications with necessary masonary work
4
-
-
Supply and laying of 40/6mm copper flat for earthing
20
-
-
Supply and laying of 50/6mm GI flat for earthing
60
-
-
Supply delivery and fixing of LDB with 1 No. incoming 32 A TPN MCCB and 1 No. outgoing SP MCB
1
-
-
Supply and laying of 4 Core 10 sqmm LT UG cable in trench to be excavated at adepth of 2.5' putting 6" layer of sand and co0vering the cable with brick and sand, refilling the earth to make good
-
-
-
Length
150
-
-
Joints
2
-
-
Run of 2 of 2.5 sq.mm. PVC unsheathed copper SC cable in PVC pipe for mains with continuous earth connection by 14 SWG TC wire
500
-
-
Supplying and fixing of industrial type 4' 40W twin Fl. fitting complete with tube in conduit pipe suspension with connection.
20
-
-
Supplying and fixing of 12” sweep AC exhaust fan complete including providing necessary opening in the wall
12
-
-
Preparation of drawings and documents and obtaining necessary statuatory approvals from CEIG etc. complete
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements