Chennai Metropolitan Development Authority Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Development Authority Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Dec 2024
Closing Date16 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling, Plain cement concrete and clearing away the same 50 m away from the site and roughening the surface etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge.

42

-

-

-

-

-

... More
Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).

-

-

-

... More
Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work.

-

-

-

... More
450mm Dia Pile

1386

-

-

... More
Providing UNDER REAMED PILE SR.C.C.30cm (12") dia cast-in-situ with single reamed (bulb) in cement concrete 1:1.5:3, 11.5cm above G.L. including boring, erecting, vibrating,curing, hire charges for drilling equipments, etc.,complete as per relevent ISI specifications(excluding cost steel reinforcement).

-

-

-

... More
300mm Dia Pile

148

-

-

... More
Carrying out initial working pile load test on specified dia piles as specified in IS:2911 (Part 4). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete.

1

-

-

... More
Carrying out Dynamic load test on Bored cast-in-situ pile as specified in IS:2911 (Part 4)for specified test loads.( 450 mm dia ). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete

3

-

-

... More
Supply Conducting Pile integrity test (PIT) on the piles under each cluster by using a 6 lbs nylon lipped hand held hammer, glueing sensitive accelerometer on top of the pile by petro wax or petroleum jelly after making the pile head smooth and even by disc grinder, providing stage wise and final report along with revevant conclusions etc., as directed by Client / engineer-in-charge.

15

-

-

... More
Earth work excavation and desposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth, shales, murram, gravel, stony earth and earth mixed with small size boulders et., As per SS 20B excluding hard rock requiring blasting inclusive of shoring shuttering, baling ojut water where ever necessary and including refilling consolidation etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers.

-

-

-

... More
0.0m to 2.0m depth

439

-

-

... More
2.0m to 3.0m depth

28

-

-

... More
Supplying and Filling with M - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification.

122

-

-

... More
Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive of giving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12"to a depth of 8" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc.,

576

-

-

... More
Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation.

-

-

-

... More
Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth.

-

-

-

... More
Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over.

-

-

-

... More
Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12" to a depth of 8" around the building before laying the plinth projection. This holes has to be be closed after the treatment.

-

-

-

... More
Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge.

224

-

-

... More
Providing and laying plain cement concrete 1 : 4 : 8 ratio of (1 cement , 4 sand and 8 graded stone aggregate 40mm nominal size) in foundation and basement including dewatering wherever necessary and laid in layers not more than 15 cm thick and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification.

105

-

-

... More
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members

669

-

-

... More
For Vertical surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical walls etc.

320

-

-

... More
for plane surfaces such as rectangular or square rcc columns, sunshades, top and bottom slab of rcc boxing, etc.

915

-

-

... More
For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.

2011

-

-

... More
Extra for additional height in centering, shuttering wherever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels. over a height of 3 30 m (height shall be the dimension as measured from the top of the lower slab/pcc sub base to the bottom of the subsequent upper stab) for every additional height of 1m or part thereof for plan area to be measured Suspended floors, nat slabs. drops. post tensioned slabs, slabs curved in plan to any radius, grid slab, rools landings beams including spiral and curved beams of all radius, post tensioned beams, gnd beams, plinth beams. girders, bressumers. cantilevers and balconies. Rate to include all matenals, labour charges, wastages placing. transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge

2040

-

-

... More
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge. The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge

-

-

-

... More
Basement:-

256

-

-

... More
Ground Floor:-

156

-

-

... More
First Floor :-

156

-

-

... More
Second Floor:-

101

-

-

... More
Terrace Floor:-

39

-

-

... More
Supplying, fabricating and fixing in position of steel Fe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

132

-

-

... More
Supply and constructing Fly ash Brick masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure using Fly ash Bricks of size 230x110x75mm etc., complete complying with standard specification and drawings and as directed by the Engineer -in-charge.

-

-

-

... More
Basement:-

41

-

-

... More
Ground Floor:-

67

-

-

... More
First Floor :-

99

-

-

... More
Second Floor:-

165

-

-

... More
Terrace Floor:-

40

-

-

... More
Supply and constructing Flyash Brick partition wall 115mm thick in Cement Mortar 1:3 (one cement and three M sand) 11.50 CM thick using using Fly ash Bricks of size 230x110x75mm using hoop iron reinforcement if found necessary and hoop iron shall be supplied to the department at free of cost etc., complete as directed by the Engineer in- charge.

-

-

-

... More
Stilt Floor :-

58

-

-

... More
First Floor :-

133

-

-

... More
Second Floor:-

103

-

-

... More
Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

1349

-

-

... More
Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of P sand) according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. The rate including cost of all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

2395

-

-

... More
Plastering 15 mm thick for external surfaces with Cement Mortar 1:4 (1 of cement : 4 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer's Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

1929

-

-

... More
Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

938

-

-

... More
Supplying and laying of Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. (Including Skirting work)

842

-

-

... More
Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colour with base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

152

-

-

... More
Supply and Laying with the best quality approved kotta stone slab not less than 20mm thick and the size of slab 600 X 600 mm machine cut and machine high pre - polished set in C.M 1:4 20 mm thick with white cement sluury for surface contact of the bottom of the kotta slab as per approved pattern / design as per the drawings by using irrespective of size and shapes including finishing the joints with white cement sluury, cutting, edge chamfering and polishing rough, medium nice and acid wash and tin - oxide polish. Rate including all materials labour Charges, wastages, Necessaryleads & lifts working at all levels transportation charges loading and unloading, preparation of surfaces, necessary hacking in RCC surfaces cutting to required shape tool, and plants fuel, curing, cleaning acid wash over finished surfaces, protection with Gypsum / Pop layer over plastic sheet and removing the same before handling over as complete with all respects complying with relevant standard specifications and as directed by the Client / Engineer in Charge

132

-

-

... More
Supply and Laying flooring with best quality approved colour 18mm thick Flamed Steel Grey Granite Slab for Staircase and Ramp flooring of size not less than 1200 x 600 mm machine cut and set in C.M 1:4 (1 of cement: 4 of manufactured sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading. preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, antiskid grooves,tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum/Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
Staircase

115

-

-

... More
Lift Facia

39

-

-

... More
Skirting

14

-

-

... More
Supply and fixing of Polished granite slab ,18 mm thick (average), for flooring including fixing in position cutting , chipping the wall, masonry touch up works etc., complete in all respects for all floors as directed by the departmental officers.

265

-

-

... More
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

263

-

-

... More
Supplying and fixing following thickness of cuddapah slab for cupboard 25mm. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, with all respects complete complying with relevant standard specification and as directed by the Engineer-in-charge

12

-

-

... More
Toilet Sunken using broken brick jelly 20 mm gauge The proportion of broken brick jelly to slaked lime being 1:3:6 (1part cement,3 part fine aggregate & 6 part broken brick jelly), well beaten by wooden beaters for giving required slope and thickness required etc complete complying with standard specifications and as directed by Departmental Officers.

27

-

-

... More
Weathering course-using broken brick jelly 20 mm gauge in pure slacked lime (No sand to be used) over RCC roof slab. The proportion of broken brick jelly to slaked lime being 32:12½ cft well beaten by wooden beaters for giving required slope. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, with all respects complete complying with relevant standard specification and as directed by the Engineer-in-charge

38

-

-

... More
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.

324

-

-

... More
Waterproofing Application to Terrace Roof Slab - Surface Preparation Cleaning the treated surface from dirt, dust etc., complete so as to get clear surface for application of primer. - Application of Primer Providing and applying single coat of epoxy resin based acrylic primer cum sealer Maxshield® Primer (Manufactured by M/s. Thermax Ltd) at an coverage of 5 - 6 sqm per ltr depending upon surface before further application of waterproofing coat or as per manufacturers' specification. - Application of Waterproofing Coating Providing and applying two coats of single component solvent based polyurtehane waterproofing coating Maxshield® PF 900 (Manufactured by M/s. Thermax Ltd) reinforced with nonwoven geotextile fabric of 60 GSM Maxshield® FABRIC (Manufactured by M/s. Thermax Ltd) soaked in Maxshield® PF 900 at an coverage of 2 kg per sqm including curing as per manufacturers' specification. The rate including cost of all materials, surface preparation, application of primer, application of waterproofing coating, labour charges for all layers and transportation charges and loading & unloading charges etc., complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

189

-

-

... More
Paving the Top of roof with Solar refelective tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as per the direction of the Engineer-In-Charge. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)

183

-

-

... More
Supplying and laying Tamin Paver Block with pattern 80mm thick, Grey , Black and Red colour of approved sample as per designed Pattern / drawing made of M40 concrete - 80 mm thick including transportation of the blocks to the site preparation of surface including supplying and filling with manufactured sand to 50 mm thick, levelling and compacting with plate vibrator and laying of the inter locking paving blocks with sand binding and final compaction with plate vibrator of 3 tonne capacity finishing the surface including cutting of blocks at the edges including all labour, materials, transportation, shifting etc., complete, as directed by the Engineer-in-charge.

393

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of all materils, Labour charges for cutting, bending, welding, grinding, polishing, Transportation, electrical charges, etc. complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

55

-

-

... More
UPVC Window :Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm125GSMand 100% corrosion free, the profiles are multichambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided withEspag multi power point locks and also it operates ashandle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong lockingsystems and as per size for arresting noise and energyloss. The connecting mechanism between sash andouter frame that enables opening of the window. Thewindow should be fixed to the wall with 100% packingwith screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work.

70

-

-

... More
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work

6

-

-

... More
Providing of 35mm thick factory made pre - laminated ABS ( Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent desings consisting of all round frame made out of water proof solid PVC bar of size 20 X 32 mm reinforced by 32 X 32 mm 2 nos ., for vertical made out of LVL core material of 32 mm thick high density craft paper honey comb board, sandwiched on both sides with pre- laminated ABS sheets thickness of 1.5mm PVC edge bending of size 0.45mm on the vertical sides. hardware made out of steels coated butterfly hinges - 3nos for each shutter and ISI make SS round lock Complete complying with the standadrd Specification . the door shutter and frame should be got approved from the Departmental Engineer before on use.

35

-

-

... More
Flush doors : Supplying and fixing single leaf flush door 32/30mm thickness poth side commercial ply and approved brand Century/ Merino/ Greenlam with T.W.frames of size 100x75mm at side verticals and top, 6Nos.of iron hold fast fixed in C.C.1:2:4 and 3Nos.of butt hinges 125mm long including wind appliances furniture iron fittings 2Nos.of iron pad lock 15cm long for locking arrangements and fixed in position as directed during execution.

86

-

-

... More
Best Indian Teak Wood panelled and glazed door in double shutters with glazed head. The size of frames shall be 100x75mm at side,verticals,top transom and centre vertical for head. The height of glazed head is 40cm using 595 gm.glass panes for head. The shutters shall be of 40mm thick with moulded panels in 20 mm thick planks for the panelled portion and 595gm.glass panes for the glazed portion. 6Nos.of iron hold fasts fixed in C.C.1:2:4. 6Nos.of butt hinges 125mm long including wind appliances, furniture iron fittings.1No.of iron padlock 15cm long for locking arrangements and fixing in position with 2Nos.of 20mmdia M.S horizontal bars for the head portion, etc., complete.

10

-

-

... More
Supply and Installation of Patch fitting glass doors with 12mm thick toughened glass and standard patch fitting accessories like top patch, top spindle, bottom patch and floor spring with spindle, SS universal cover plate of 1.5mm thick, necessary sealing compound and cement box etc., The floor spring should conform to DIN EN 1154 suitable for single and double leaf doors to a maximum weight of 120 kgs. The spring strength shall be EN 1-4, single sided, with mechanical back check and hold open function.The rate should be inclusive of all the works mentioned above including standard bottom lock with EPC and SS Handle.the rate to include all the works mentioned above for completeCut out& hole, installation,Loading and unloading,Transportation and Working at all levels and heights and as directed by Engineer- in- Charge.

25

-

-

... More
Providing and fixing welded M.S. grills to the window openings,along the details as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Engineer-in-charge.

2508

-

-

... More
Designing, Providing and fixing in position Hot rolled structural steel Members / Sections consists of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, flats etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint of Akzonoble make and total dry film thickness 225 microns. (Only Main structural supports related to Facade works if required any shall be considered and no base frame or support structure shall not be considere, which shall form part of the respective cladding and Glazing items). Refer Particular Specification for Mode of measurement for this item. The rate including the cost of all materials,labour,tools,tackle and plants, wastage etc.,as per specification and drawings complete. The rate including cost of bolts, nuts, washers, welding, electrodes and connections required for the work. No extra on this account will be paid for. The rate to include preparation of fabrication shop drawings for departmental engineer-in-charge approval before commencement of work.

14655

-

-

... More
Providing and Fixing of polyurethane foam for Sloped roofas thermal insulation panels or Sandwich insulated panels with external 0.50mm total coated thickness pre painted Galvalume sheet with trapezoidal roofing profile having crest height of 38mm at every 333mm span , whereas internal 0.50mm total coated thickness pre painted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification.

472

-

-

... More
Providing and Fixing of RW Gutter with using 0.5mm GI Sheet with necesarry supports.The work carry out as per drawing .The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, with all respects complete complying with relevant standard specification and as directed by the Engineer-in-charge

41

-

-

... More
Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer

751

-

-

... More
Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept. Officials.) Design the framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere

110

-

-

... More
Supply and fixing RCC precast slab manhole cover SFRC of 50mm thick and required size 600mm x 600mm made with RCC 1:11/2:3 using 20mm HBG jelly and 8mm TMT rods at a spacing of 150mm c/c, on both direction including cost and conveyance of all materials, labour and transportation etc complete complying with standard specification.

8

-

-

... More
Supply and fixing PVC mould CI steps

16

-

-

... More
Supply and painting of two coats of Acrylic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer. The rate including cost of all materials, brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.(Internal surface)

2807

-

-

... More
Supplying and painting of 2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. The rate including cost of materials, brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

1778

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. ( The make quality and colour of paint should be got approved by the executive Engineer before use on works.)

122

-

-

... More
Supply and fixing seamless ceiling with Gypboard of 12.5 mm thick, fixed by using 25 mm long dry wall screws to the under side of the suspended G. I. channels grid. comprising of main, intermediate and perimeter runners, approximate sizes for the same are 80 x 26 x 0.5 mm @ 450 centre to centre, 45 x 15 x 0.09 mm @ 1200 centre to centre and 20 x 29 mm respectively. Grid is suspended by G. I. soffit cleat (37 x 27 x 1.6 mm) using metal expansion fasteners of 12.5 mm dia, 35 mm deep, 6mm dia bolt. G. I. connecting clips and other accessories to comply with I. S. 2095 - 1982 and as per manufacturer specifications. All joints shall be finished with joint paper tape by using jointing compound of India Gypboard Ltd. and applying over it 3 layers of the filler compound to provide a smooth surface. The rate shall include making cut outs for tube lights, spot lights, duct doors, for specified size, grills etc. for which no extra payment will be paid. Area of cut outs will be deducted as per IS 1200. All curved surfaces, recesses, waffles & corbellings shall be part of the flat area measurement, without any extra cost for the same. If the vertical surface is more than 300 mm then only, it will be counted for measurement. Rate shall include the peripheral ply wood boxing / rough wood frame wherever required.The rate are included two coat of puuty,one coat of primer and two coat of Acrylic emulsion paint .Entire work shall be carried out as per the detailed technical specifications, drawings and as per the instruction of Engineer- in- charge.False Ceiling upto a ceiling height of 6.0 m from floor level.

372

-

-

... More
Supply and fixing Orion panel post inclusive of panel, Post and anchore fastener.Standard panels size : 1260mm x2500 / 1560mmx2500mm, 1860mmx2500mm / 2060mmx2500mm and 2460mmx2500mm (for boundary fencing) with proper laying of make quality and colour should be got approved by the executive Engineer before use on works.The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

185

-

-

... More
Supplying,Fixing and testing of RO unit with dispenser (50 Ltr per hr) with the folloing specification. 3 Tap Normal Water, Commercial range, Stainless steel 304 storage tank and body, Floor standing type with four leg, automatic filling type.

1

-

-

... More
Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails.

-

-

-

... More
Upto 3 M Height

194

-

-

... More
For every additional height of 2.5 M (3m - 5.50m)

194

-

-

... More
For every additional height of 2.5 M (5.50m -8.00m)

116

-

-

... More
For every additional height of 2.5 M (8.00m -10.50m)

116

-

-

... More
For every additional height of 2.5 M (10.50m -13.00m)

116

-

-

... More
Plumbing Abstract

-

-

-

... More
PART - A SANITARY FITTINGS

-

-

-

... More
Supplying and fixing in position Indian water closet of size 580 x 440mm, glazed earthern ware of approved quality and colour with 'P' trap or 'S' trap confirming to IS:2556-part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One of Lime, Two of Sand, Five of Brick jelly) 100mm thick and by dismantling brick masonry, reinforced finishing to the required slope and including giving necessary connection to PVC soil pipes cement concrete roof / floor slab and making good the disturbed portion to origional condition without leakage etc., complete complying with standard specification and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works)

4

-

-

... More
Supply and fixing in position white European Water Closet of approved make with Porcelain low level flushing tank 12.5 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directed by the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.

12

-

-

... More
Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre long flexible tube including cutting and making good the walls wherever required etc complete. complying with standard specification and as directed by the Department officers. The quality and make of health faucet should be got approved by Concern department Engineer before use on work.

12

-

-

... More
Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia ' B ' Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass Nipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The Wash basin should be got approved by the Executive Engineer before use on works.

24

-

-

... More
Supplying and fixing Lipped Mouth Porcelain Flat Back Urinal(white colour) of size 26.5x31.5x44cm with all accessories such as 32mm dia Bell Mouth PVC Connection, 15mm dia GM Wheel Value, 15mm dia 'B' Class GI Waste Water Pipe, 15mm dia Nylon Connection, 15mm dia Brass Nipple, and suitable screws, shellac etc., complete. The rate including cost of all materials, labour charges for fixing and transportation etc. completed as directed by Engineer-in-Charge.

6

-

-

... More
Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work.

20

-

-

... More
Supplying and fixing Brass Chromium Plated Towel Rail 60cm long and 20mm dia with brackets of same materials including cost of teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.

5

-

-

... More
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) .

26

-

-

... More
Supplying and fixing heavy duty 15mm CP shower unit comprising of CP 15mm dia hot & cold mixer with CP spout, overhead shower set comprising of CP shower arm, rose etc.,complete with CP wall flanges. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge.

4

-

-

... More
Supplying,installing,testing and commissioning of approved make stop cock for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work.

5

-

-

... More
Supplying and fixing of Angle cock Fitting including cost of fittings labour for fixing etc., complete complying with relevant standard specification and as directed by the departmental office, (The quality of fittings should be got approved from Executive Engineer before use).

8

-

-

... More
PART - B SOIL, WASTE AND VENT PIPE LINES

-

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). (Internal & External)

-

-

-

... More
50mm dia. 6 kg / sq.cm. PVC pipes.

30

-

-

... More
75mm dia.6 kg / sq.cm. PVC pipes.

98

-

-

... More
110mm dia. 6 kg / sq.cm. PVC pipes.

155

-

-

... More
160mm dia. 6 kg / sq.cm. PVC pipes.

156

-

-

... More
Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) including dismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ).

31

-

-

... More
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).

-

-

-

... More
75mm dia

5

-

-

... More
110mm dia

7

-

-

... More
PART-C - EXTERNAL DRAINAGE

-

-

-

... More
Supplying & fixing in position 150 X 100 mm square mouth 'P' or 'S' trap stone ware Gully trap 'A' grade with cast iron double gratings of size 150 X 150 mm with C.I. air tight cover with frames of size 300 X 300 mm at bottom & top respectively with necessary earth work excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150 mm thick using 20 mm size broken brick jelly including necessary brick work & plastering, &including dismantling masonry wherever necessary & redoing the damaged portions to the original condition & by using cement concrete 1:3:6 using 20 mm stone jelly for fixing the Gully trap & giving connections to the stone ware sewer line etc., complete, complying with standard specification. (The stone ware gully trap should be got approved by the Executive Engineer before use on works ).

5

-

-

... More
Constructing Fly ash brick masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mix for base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floating coat of neat cement ,supplying and fixing SFRC manhole cover with farame of size 600x600 mm , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works)

-

-

-

... More
600x600mmx 600mm deep to 1000mm deep

14

-

-

... More
Construction of Rain water Recharge well (1500mm dia) as per consultant drawing with necessary connections, Earth work - digging the well for recharge well.supply and installation of Reinforced concrete Rings - 5 feet OD & 1 feet Height, 50 MM Thick - 10 no's. supply and installation of Reinforced concrete slab- 5 feet in dia, 200 mm thick, and 25 mm perforated - 8 mm mild steel rods used for reinforcement -1" Perforated - 1no's.supply and installation of Reinforced concrete closing slab - 3 feet in dia OD, 75 mm thick, 8 mm mild steel rods used for reinforcement with 600mm x 600mm Square FRP/Plastic manhole cover - 1no's.supply and installation of MS grating - 6*6inch square - 2no'sFiltration Media Installation For recharge Well Unit: 40 mm crushed stones - 0.12cum, 20 mm crushed stones - 0.12cum, Brick Bats - 0.12cum, Mixture of Brick Bats and Gravels for filling the gap between excavated earth and RCC rings- 1.6cumShifting of excavated earth to the approved / authorised dumping yard as directed by the authorities / Site in charge. supply and installation of `V' WIRE SCREEN - 0.75 mm Slots. SS-304 Material - 0.5 mtrs Height - 6 " diameter - 2no's Drilling a bore well - 200mm dia by high speed compressor- 4MTRS. supply and installation of 110mm PVC PIPE PN-6 - 4 rmtr, 110mm PVC PIPE PN-6 Perforated with 10 mm Zigzag holes to easy percolate the water - 4 rmtr, 12mm Gravel Packing between bore well hole and PVC pipe and Inserting into the Bore Well- 4 mtrs. supply and installation of - 180GSM Gio-fabric sheet to cover V-Wire screen,Shifting of excavated earth upto 1000mtrs as directed by site in charge. (the well sholud be got approved by the Executive Engineer before use on works)

2

-

-

... More
Size - 1500mm diameter, 4.0 mtr depth and 200mm dia bore upto 4 rmtr.

-

-

-

... More
D. WATER SUPPLY SYSTEM

-

-

-

... More
Internal Concealed Works

-

-

-

... More
Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. (Internal & Extenal)

-

-

-

... More
20 mm nominal (OD) pipes

115

-

-

... More
25 mm nominal (OD) pipes

66

-

-

... More
32mm nominal (OD) pipes

30

-

-

... More
E.EXPOSED &EXTERNAL PLUMBING WORKS

-

-

-

... More
Providing, supplying & laying of Unplasticized Polyvinyl Chloride (UPVC-SDR-11) Pipes conforming to IS 15778 having thermal stability cold water with brass and UPVC fittings like Elbow,Brass Tee, Brass Elbow,Offsets,Tee with clamps @1.00 meters spacing, with jointing of pipes with one step UPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour, transportation,tools & tackles all complete as per as per specifications,Concealed work including chase cutting) complete complying with standard specification and as directed by the Departmental Officer.

-

-

-

... More
20mm nominal(OD) pipes

10

-

-

... More
25mm nominal(OD) pipes

50

-

-

... More
32mm nominal(OD) pipes

110

-

-

... More
40mm nominal(OD) pipes

85

-

-

... More
50mm nominal(OD) pipes

70

-

-

... More
Supplying & fixing in position first quality & approved variety of various dia Brass Ball Valves with I.S.I. Mark of the following size including cost of Shellac, thread etc.,including labour for cutting & threading of Pipes etc., complete complying with standard specifications for both internal & external water supply arrangements.

-

-

-

... More
20 mm dia

4

-

-

... More
25 mm dia

4

-

-

... More
32 mm dia

11

-

-

... More
40 mm dia

2

-

-

... More
50 mm dia

9

-

-

... More
Providing and fixing gun metal Non- return valve of approved quality (screwed end) :

-

-

-

... More
32 mm dia

3

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

3

-

-

... More
Providing, installation, testing and commissioning approved make CI Y-type Strainer conforming to IS standard with necessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications.

-

-

-

... More
50 mm dia

3

-

-

... More
Supply, fixing and testing of brass Automatic Air release valve approved quality for booster line Vertical downtake.

-

-

-

... More
50 mm dia

3

-

-

-

-

-

... More
Supplying and erection submersible pump set of Three phase 5.00 H.P of best approved quality and make with ISI mark including fixing of starter,main switch and panel board with necessary labour including run off 4 of 10 Sq,mm, in P V C pipe with 14 SWG TC wire including fixing of suction pipe and foot valve etc., complete and operating the pumps on trial run for 3 days. (The make and quality of pump set to be got approved by the Executive Engineer before use on works.)

1

-

-

... More
Supplying and erection Booster Pump set of Single phase 1.50 H.P of 100 LPM @ 2.5 bar1.1kw,Speed of 2900rpm,210 V and 50Hz best approved quality and make with ISI mark including fixing of starter,main switch and panel board with necessary labour including 24Lts MS tank,Pr. Switch,Pr.Gauge,5way connector along with run off 4 of 10 Sq,mm, in P V C pipe with 14 SWG TC wire etc., complete and operating the pumps on trial run for 3 days. (The make and quality of pump set to be got approved by the Executive Engineer before use on works.)

1

-

-

... More
BOREWELL

-

-

-

... More
Drilling of 12" dia vertical borewell so as to have a finished size of 6" dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractor's rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs.

-

-

-

40

-

-

100

-

-

... More
Reaming from 200mm dia pilot bore to 350mm dia bore as direct by the Engineer incharge up to 80mtr depth ending below ground level

140

-

-

... More
Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992

-

-

-

... More
200mm dia CS ( plain pipe

20

-

-

... More
200mm dia RS

20

-

-

... More
150mm dia RS

100

-

-

... More
Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers.

-

-

-

... More
200mm dia CS

20

-

-

... More
200mm dia RS

20

-

-

... More
150mm dia RS

100

-

-

... More
Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock. (1 No of Bore well =12 Cum of Pebbles ) Notes: Depth of bore well 70m

2

-

-

... More
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by 'V' notch method.

16

-

-

... More
Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge.

2

-

-

... More
Electrical Abstract

-

-

-

... More
Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steel made up of 2mm powder coated MCCB Indoor Type Three Phase Changer Over panel suitable to accommodate 1no. 160A 4 pole Three phase Change Over Switch for EB Source and as incomer for DG Source , 1no 160A 4Pole MCCB as incomer, 1no 125A TPN MCCB, 2nos of 63A TPN MCCB's, compartment for as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 33x6mm Al busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost of Weldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S

1

-

-

... More
Supply and fixing, testing and commissioning of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door) with 1 no. 125 A 4 P MCCB switch as incoming and 8 nos. 6-32A TP MCB ,as outgoing with suitable cable end box on wall with earth connection only.

1

-

-

... More
Design, supply, fixing, testing and commissioning of 4 Way Vertical Three phase distribution board with MCBs in IP 42 protection sheet metal enclosure with 4 pole, 63A MCB as incomer, 4nos 6-32A TP MCB as outgoing, with copper bus bars and neutral link and all mounting accessories.

1

-

-

... More
Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings. 1no. 4 pole 63amps incoming MCB, 1no no. 4 pole 30ma / RCD. sub phase incomers 3 nos 32A DP MCB, final outgoinfs 6-32A SP MCB 18 nos, and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only.

4

-

-

... More
Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings. 1no. 4 pole 63amps incoming MCB, 1no no. 4 pole 30ma / RCD. sub phase incomers 3 nos 32A DP MCB, final outgoinfs 6-32A SP MCB 12 nos, and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only.

2

-

-

... More
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only.

1

-

-

... More
CABLE

-

-

-

... More
Supply and Laying of 3.5c x 70 sq.mm.Aluminium conductor, 1100v, ISI Mark, PVC/XLPE armoured LTUG cable in a existing trench / Tray / HDPE pipe

100

-

-

... More
Supply and Laying of 3.5c x 50 sq.mm.Aluminium conductor, 1100v, ISI Mark,PVC/XLPE armoured LTUG cable in a existing trench / Tray HDPE pipe

60

-

-

... More
Supply and Laying of 3.5c x 25 sq.mm.Aluminium conductor, 1100v, ISI Mark, PVC/XLPE armoured LTUG cable in a existing trench / Tray / HDPE pipe

20

-

-

... More
Supply and Laying of 4c x 16 sq.mm.Aluminium conductor, 1100v, ISI Mark, PVC/XLPE armoured LTUG cable in a existing trench / Tray/ HDPE pipe

150

-

-

... More
Supply and Laying of 4c x 10 sq.mm.Aluminium conductor, 1100v, ISI Mark, PVC/XLPE armoured LTUG cable in a existing trench / Tray/ HDPE pipe

250

-

-

... More
Supply and Laying of 2c x 6 sq.mm.Aluminium conductor, 1100v, ISI Mark, PVC/XLPE armoured LTUG cable in a existing trench / Tray / HDPE pipe

375

-

-

... More
Cable Gland

-

-

-

... More
Supply and fixing of brass cable gland for 3.5 x 70 sq.mm PVC/XLPE LTUG armoured cable with earth connection with necessary accessories etc

4

-

-

... More
Supply and fixing of brass cable gland for 3.5 x 50 sq.mm PVC/XLPE LTUG armoured cable with earth connection with necessary accessories etc

2

-

-

... More
Supply and fixing of brass cable gland for 3.5 x 25 sq.mm PVC/XLPE LTUG armoured cable with earth connection with necessary accessories etc

2

-

-

... More
Supply and fixing of brass cable gland for 4C x 16 sq.mm PVC/XLPE LTUG armoured cable with earth connection with necessary accessories etc

12

-

-

... More
Supply and fixing of brass cable gland for 4 x 10 sq.mm PVC/XLPE LTUG armoured cable with earth connection with necessary accessories etc

12

-

-

... More
Supply and fixing of brass cable gland for 2 x 6 sq.mm PVC/XLPE LTUG armoured cable with earth connection with necessary accessories etc

6

-

-

... More
CABLE TERMINATION

-

-

-

... More
Supply and providing cable end termination of 3.5 x 70 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete and etc to complete the work

4

-

-

... More
Supply and providing cable end termination of 3.5 x 50 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete and etc to complete the work

2

-

-

... More
Supply and providing cable end termination of 3.5 x 25 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete and etc to complete the work

2

-

-

... More
Supply and providing cable end termination of 4 x 16 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete and etc to complete the work

12

-

-

... More
LIGHT FIXTURES

-

-

-

... More
upply and fixing of 18W,150mm dia, LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.

45

-

-

... More
Supply, installation and commissioning of 15W, 150mm dia, Surface mounting , LED fixture in Die cast Aluminium enclosure, with 100 lumens/Watt efficiency, with internal driver and complete with all accessories

90

-

-

... More
Supply, installation and commissioning of 15W, Recessed mounting , LED fixture in Die cast Aluminium enclosure, with 100 lumens/Watt efficiency, with internal driver and complete with all accessories - MR

45

-

-

... More
Supply, installation and commissioning of 15W, Wall mount with bracket , LED fixture in Die cast Aluminium enclosure, with 100lumen/Watt efficiency, with internal driver and complete with all accessories.

25

-

-

... More
Supply, installation and commissioning of 10 W, Compound wall/Gate light, 300mm dia, 450mm height, LED light fixture with support pipe, in Die cast Aluminium enclosure, with 100lumen/Watt efficiency, with internal driver and complete with all accessories

20

-

-

... More
Supply, installation of 4 feet , 20W, LED Surface mounted LED light Fixture with accessories

30

-

-

... More
Supply, installation of 2 feet , 12W, LED Surface mounted LED light Fixture with accessories for Mirrors.

20

-

-

... More
Supply, installation and commissioning of 50 W, LED Focus Light with optics and adjustable mounting bracket ,100 lumens /Watt efficiency, with internal driver and complete with all accessories. Equivalent to

5

-

-

... More
Supply, installation and commissioning of 50 W, LED Chandelier Light support system for suspended mounting ,100 lumens/Watt efficiency, with internal driver and complete with all accessoriES

7

-

-

... More
Supply, installation and commissioning of LED Strip Light for Cove lighting with 5050 leds, Water proof, minimum 6W per mtr and suppor drive for every 10mtrs.,

80

-

-

... More
Wiring for Light and Sockets

-

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End

20

-

-

... More
Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.

420

-

-

... More
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion

1030

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil)

310

-

-

... More
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point

6

-

-

... More
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.

50

-

-

... More
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.

5

-

-

... More
Supply and fixing of 1no.6A two module socket , 1 no. 6/16A two module socket, 1 no. 6A one module switch, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.

20

-

-

... More
Supply, installation and commissioning of 25A Flush type Wall Socket with 25A DP MCB for AC Plug

5

-

-

... More
Supply, installation of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300mm width and 50mm height perforated cable tray in wall / Celling with necessary support and hardware

40

-

-

... More
Supply, installation of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 150mm width and 50mm height perforated cable tray in wall / Celling with necessary support and hardware

25

-

-

... More
Supply, installation of Fan Clamp (Dia 12mm) with 6mm MS Side Plates & 45cm Cross Arm

50

-

-

... More
supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod on the existing fan clamp

25

-

-

... More
Supply and installation of 450mm Wall mounted Air Circulator fan with regulator and accessories

8

-

-

... More
Supply and installation of 300mm exhaust fanSupply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall

9

-

-

... More
Supply and installation of MS / Fibre Louvers Shutters arrangements for 300mm AC Exhaust Fan

9

-

-

... More
Supply and run of No.8 SWG GI wire for earthing

390

-

-

... More
Supply and run of 25 x 6mm GI flat for earthing in wall/ Ground / Trays with necesaary clamping hardwares

120

-

-

... More
Supply and installation of GI Plate Earthing as per IS 3043 with 600 x 600 x 6mm GI pipe including excavation, Back filling with charcoal and salt, Chamber construction with heavy duty cover

2

-

-

... More
Supply and Laying of 50 mm HDPE pipe in Under ground by excavation of trench a depth of 0.75 meter and refilling the earth to make good.

50

-

-

... More
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete

1

-

-

... More
Supply, Installation, Testing and Commissioning of CCTV System

-

-

-

... More
SSupply & Installation & Commissioning of 1/3'' CMOS,1280x960:25fps(P)/30fps(N), 0.01lux/f1.2, 4mm/f1.8 lens, Electronic Day/Night Network Dome Camera (with mounting bracket adjustable type)

15

-

-

... More
Supply & Installation of Network Video Recorder with 4HDDs Storage Capacity, 32-Channel Video, 2 Client Licenses, & supports H.264 Compression, Real time Surveillance, With 2 CIF Resolution 25 FPS

1

-

-

... More
Supply & Installation of 42" LCD TV

1

-

-

... More
Supply & Installation of 10 TB hard disk (45 Daya Backup)

1

-

-

... More
Supply & Installation of 24 Port Layer 2 manageable POE Network switch (24 PORT-10/100 BASE-T & 2 NOS. 1-G COMBO PORT FOR UPLINK)

2

-

-

... More
Supply & Laying of CAT6 SL Series Patch cords Panel Side

15

-

-

... More
Supply & Laying of CAT6 SL Series Patch cords Camera Side

15

-

-

... More
Supply & Laying of (Combo D-RJ45 CAT6E Lan I/O Network Keystone Jack, Gang Box, Single Port faceplate panel side

15

-

-

... More
Supply & Laying of (Combo D-RJ45 CAT6E Lan I/O Network Keystone Jack, Gang Box, Single Port faceplate camera side

15

-

-

... More
Supply & Laying of CAT6 UTP Cable with PVC conduit

250

-

-

... More
Supply, Installation, Testing and Commissioning of Public Address System.

-

-

-

... More
Supply, Installation, Testing & Commissioning of 6W RMS False Ceiling Mount Speakers with pre fabricated ceiling mount box type with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications

35

-

-

... More
Supply, Installation, Testing & Commissioning of System Controller complete with Microprocessor based 6 Zone Call Station, Stem Type Microphone (to be integrated with fire alarm system)

1

-

-

... More
Supply, Installation, Testing & Commissioning of Rack Mounted 480 W Power Amplifier with USB paly back option as per specifications

1

-

-

... More
Supply and Surface laying of 2 core x 1.5 sq.mm black colour twisted pair shielded multi strand ATC armoured FRLS cable

600

-

-

... More
Supply, Installation, Testing and Commissioning of ANALOG ADDRESSABLE FIRE ALARM SYSTEM

-

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable Intelligent Networkable single loop Fire Alarm Panel with battery back up, power supply, facility to add minimum 2 more loop card and the necessary interface card to connect a repeater panel and all hardware & software as per specification.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Analog Addressable Smoke cum Heat Detector at Above false ceiling as per specification - Metal Back box with necessary gland for the above detector to be considered

45

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable Manual call point as per specification

6

-

-

... More
Supply, Installation, Testing & Commissioning of Sounder cum strobe as per specification

6

-

-

... More
Supply, Installation, Testing & Commissioning of Bell control module

3

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable Control for tripping

4

-

-

... More
Supply, Installation, Testing & Commissioning of Short Circuit Isolator as per specification

3

-

-

... More
Supply and Surface laying of 2 core x 1.5 sq.mm Red colour twisted pair shielded multi strand ATC armoured FRLS cable

2100

-

-

... More
Supply, Installation of Power supply unit.

2

-

-

... More
Supply, Installation, Hand held & Automatic Extinguisher

-

-

-

... More
Supply of Hand held Fire Extinguisher - CO2 - 4.5 Kg with suitable Metal Floor stand MS fabricated painted in black colour

6

-

-

... More
Supply of Hand held Fire Extinguisher - ABC Powder - 6 Kg with suitable Metal Floor stand MS fabricated painted in black colour

6

-

-

... More
Supply, Installation, Testing and Commissioning of Internal hydrant system

-

-

-

... More
Supply, Erection, Testing and Commissioning of above ground piping carried out of MS class C Heavy duty pipe as per IS : 1239 for pipes up to 150mm NB and as per IS : 3589 with a wall thickness of 6.35mm for pipes 200mm NB and above together with fittings, valves and accessories as under : pipe grade shall be Fe330.Work will include all structural supports, painting for the above ground piping with one coat of primer and two coat of enamel paint of approved colour. Work will include cleaning of pipe, degreasing, etc.

-

-

-

... More
100mm nominal dia

40

-

-

... More
80mm nominal dia

12

-

-

... More
25mm nominal dia

12

-

-

... More
Supplying, Installing, testing and commissioning gear operated type butterfly valve with required flanges, nuts, bolts etc. complete.

-

-

-

... More
100mm nominal dia

2

-

-

... More
Supplying, installing, testing and commissioning of Internal Hydrant System comprising of ;

-

-

-

... More
Single headed SS hydrant valve as per IS: 5290 (Type A). The valves should be complete with hand wheels, quick coupling connections, springs and blank caps.

6

-

-

... More
2 lengths of 15 M long, 63mm dia RRL hose with couplings and Hoses shall be rolled & hug tosuitable M.S. structural support fixed inside the Fire duct wall.RRL Hose as per IS: 636.

6

-

-

... More
1 no. SS branch pipe with nozzle, As per IS: 903

6

-

-

... More
M.S. cabinet - 18 Gauge with powder coated finish of 750mm x 600mm x 250mm in size and mounted on structural support.

6

-

-

... More
Supply ,installation, testing and commissioning of Fire Hose Reel (as per ISI) wall mounted, swinging type18 SWG MS sheet, fitted with 19 mm dia x 36 M long, high pressure hose with 5 mm outlet GM nozzle with shut off valve (IS: 884-1969)includes Gate valve. and chrome plated nozzle with all necessary fixing materials complete.

6

-

-

... More
Supplying and fixing approved make 25mm dia.automatic air release valve with ball valve, unions etc. complete.

2

-

-

... More
HVAC -LOW SIDE SYSTEM Low side Air conditioning Works Supply, Installation, Testing & Commissioning & Handing over of the following: Sheet Metal Work with TDF Flanges for all sizes of the duct. Fabrication as per IS Standards Galvanizing shall be Class VII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All duct construction and installation shall be in accordance with IS standards. In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant IS codes. The Duct shall be included with Guide vanes, Adjustable splitter dampers, fastners, threaded rods, nut, Fire retardent Gasket and washers as per specs and ducts supported with Hi-tech Supports at regular intervalas as mentioned in the technical specifications.

-

-

-

... More
Air-balancing (Using Hood for CFM reading) and Minor civil works for wall opening and closing using sand cement Mortor as per site condition are included. GI Sheet Wastages will not be considered for final measurement. During construction duct end to be covered with Polythene sheet

-

-

-

... More
22 G up to 751 to 1500mm

10

-

-

... More
24 G Up to 750mm

70

-

-

... More
Supply & fixing - Extruded Aluminimum powder coated Supply air grills with VCD with necessary GI Screw, bolt, nut & supports. ( colour for the grill to b conifremed by Arch/ PMC team before placing the order)

4

-

-

... More
Supply & fixing - Extruded Aluminimum powder coated Return air grills without VCD with necessary GI Screw, bolt, nut & supports. ( colour for the grill to b conifremed by Arch/ PMC team before placing the order) Bottom throw return air grille shall be 15deg deflection, Side throw grille shall be 30deg deflection

10

-

-

... More
Supply and fixing of multiblade Opposed type Volume control damper constructed out of 18G GI damper with suitable links,and nylon bearings with quadrants and levers for manual control of volume flow of air for proper distribution and balancing of the system with lever locking facility, including necessary GI Bolt, nuts & washers.

1

-

-

... More
Supply Fabrication , and erection of Double canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc

2

-

-

... More
Supply & fixing of Thermal insulation for supply air duct using 9mm thick class " O " Closed cell nitrile rubber based elastomeric insulation with the density of 40 - 55 kg /m³ . The insulation manafactured as per BS 476 Part 7test & which should also meet UL94 supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM D 1056), should not support microbial growth (ASTM D2180, G21, G22) and should not emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.033W/m.k @ 0deg C as per DIN EN 12667. and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide 3 mm thick self adhesive tape (Black Cotton Tape not acceptable). Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre.

60

-

-

... More
Supply & fixing of Acoustic insulation for Supply air duct using 10 mm thick class 1 rating Open cell nitrile rubber elastomeric insulation with density of 140 - 180 kg / m³. The insulation manafactured as per BS 476 Part 7 & which should also meet UL 94test supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM 2180, G21, G22) and should not emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.04W/m K @ 20 degC as per DIN EN 12667. and water vapor permeance of 0.10. Adhesive shall be used additionally with VOC level not exceeding 50 grms / Litre.

30

-

-

... More
DX SYSTEM Supply, Installation,testing and commissioning of factory made DX Ceiling Suspended Ductable split package units complete with 1) Centrifugal blower, cooling coil, Insulated Drain tray, Pre-filters etc., along with matching air cooled condenser with scroll compressor. 2)Microprocessor control 3)R R410A - Gas charging, 4)Safety controls, 5) Canvass connection with moutn dampers 6) Unit electrical starter panel with PF contact for BMS ON / OFF status and monitoring through BMS. 7) Unit Starter panel shall have incomer power trip provision based on Fire alarm signal. 8) Refrigeration Controls like thermostatic Expansion valve, drier stop valve etc. 9) Internal Refrigerant piping 10) Including necessary Civil works like wall opening and closing asper site condition 11)Including installation of Indoor and outdoor units with M.S. Supports as per site condition. Capacities indicate are actual operating for chennai outside condition and for room temp of 22.7deg C with 55% RH, Condensing Temp - 135Deg F & Suction Temp - 42Deg F

-

-

-

... More
11.0TR- 4400CFM - Ceiling suspended ductable unit (Considered Single Circuit per unit)

2

-

-

... More
8.5TR- 3400CFM - Ceiling suspended ductable unit (Considered Single Circuit per unit)

2

-

-

... More
Supply & laying of 18SWG Hard drawn Refrigerant piping between indoor & outdoor units for the above DX units including pressure testing and Supports,clamps, necessary civil works like wall opening and closing for Refrigerant pipes as per site condition,etc, including Supply & laying of 13mm thick Nitrile Rubber Tubular pipe insulation for refrigerant piping.

-

-

-

... More
1-3/8"

40

-

-

... More
1-1/8"

40

-

-

40

-

-

40

-

-

... More
Supply, Installation, Testing & Comissioning of factory made Hi wall splitunit, R32 with minimum 3star rating Type Air conditioner units complete with centrifugal blower cooling coil etc., enclosed the insulation along with matching air cooled condenser with Rotary compressor all in with microprocessor control & Remote Control, Stablizer including gas charging, Supports for outdoor units, Safety controls, Power cabling and refrigerant piping between indoor and outdoor units and drain piping, etc. Units are included with all Refrigeration Controls. supports for outdoor units shall be included in the scope.

-

-

-

... More
1.5TR/450CFM HI WALL SPLIT

6

-

-

... More
Supply & laying of Softdrawn Refrigerant piping between indoor & outdoor units including pressure testing and civil works,slotted angles,Supports,clamps, etc. including Supply & laying of 13mm thick Nitrile Rubber Tubular pipe insulation for refrigerant piping.

-

-

-

60

-

-

60

-

-

... More
Supply & laying of 4C x 2.5 sq.mm Copper Armoured Power cabling between isolator to outdoor unit.

60

-

-

... More
Supply & laying of 4C x 10 sq.mm Copper Armoured Power cabling between isolator to outdoor unit.

20

-

-

... More
Supply & laying of 7C x 2.5 sq.mm Copper Control cabling between indoor to Outdoor unit.

80

-

-

... More
Supply & laying of High Density PVC drain pipe with 9mm thick Nitrile rubber insulation

-

-

-

... More
25mm dia

20

-

-

... More
32mm dia

25

-

-

... More
Supply & installation Perforated covered GI cable trays with 16swg Hot dipped galvanised including tee,right angle bends,etc., including all fixing supports and accessories etc

-

-

-

... More
150mm Wide

20

-

-

... More
300mm Wide

10

-

-

... More
Supply & laying of 8SWG Copper wire with double run from panel board to indoor & indoor to outdoor unit for Earthing.

80

-

-

... More
VENTILATION SYSTEM

-

-

-

... More
Supply ,Installation & Commissioning of propeller type exhaust fan with back draft louver.

-

-

-

... More
300cfm propeller typ exhaust fan

2

-

-

... More
750cfm propeller typ exhaust fan

2

-

-

... More
3000cfm propeller typ exhaust fan Kitchen store

2

-

-

... More
200cfm propeller typ exhaust fan - Green room & suite room

4

-

-

... More
1500cfm Cabinet type Inline exhaust fan for Stage

1

-

-

... More
Supply, Laying & Termincation of 4C x 2.5Sqmm Armoured copper cable beween isolater to Exhaust Fan

50

-

-

... More
Supply & fixing of exhasut louver with Bird Screen mesh

1

-

-

... More
Supply, installation, testing and commissioning of Independent 2KVA UPS system with 230V Single phase input and 230V single phase output with all required accessories & battery bank for 1 hour back up with covered SMF battery and battery rack for all new required loads covered in this project as per the detailed technical specification enclosed

1

-

-

... More
DIESEL GENERATOR

-

-

-

... More
Supply, Erection, Testing and Commissioning of 82.5 KVA DG Water cooled engine,3 phase,415 Volts, Standard Control panel CPCB IV + Aprroved Acoustic Enclosure,Battery and diesel tank Make : Kirloskar

1

-

-

-

-

-

... More
Supply & Installtion of 10 person capacity passenger Lift MRL, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD. .The amake quality and colour should be got approved by the executive Engineer before use on works.The rate including cost of all materials, labour charges, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.