Chennai Metropolitan Development Authority Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Chennai Metropolitan Development Authority Tender
Civil And Construction
Eprocure
Opening Date19 Sep 2024
Closing Date24 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 51,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CMDAC_474641_3Tender No
06 (MTC Junction)/2024-25Tender Authority
Chennai Metropolitan Development Authority ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and Filling with Msand in foundation and others sub structures for 100mm thick and well watered. rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling. loading & Unloading and Transportation charges etc.. complete and as per the stand specification as directed by the Engineer-in-charge..
20
-
-
Providing and laying plain cement concrete 1:4:8 (Icement: 4 sand: 8 graded stone aggregate 40mm nominal size) in foundation and including dewatering wherever necessary and laid in layers not more than 15 cm thick and consolidation etc.The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling. loading & Unloading and Transportation charges etc.. complete and as per the stand specification as directed by the Engineer-in-charge.
28.6
-
-
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., Rate to include all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Client / Engineer-in-charge.
-
-
-
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical walls etc.
165
-
-
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer. manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement, works for Footings, Grade beam, retainning wall drain wall & raft, Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades. parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant. mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages, laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs. compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.
36
-
-
Supplying And Fixing of Rubber Moulded Grey Premium Concrete Kerb of Size 450X125X300mm Using M30 Concrete. The Concrete Shall Be Moulded By Table Mount Vibrated With Polypropylene Fibers A 5% And Curing Compound. The Rate Shall Include Cost of Materials Transportation Loading Unloading Charges And All Taxes Including Necessary Earth Work Pointing With cm. 1:3 To Full Depth Curing Thread Lining Etc Complete
360
-
-
Providing of Granular Sub base using Grade I materials of table 4001 of Morth with minimum CBR 30 spreading in uniform layers with motor grader on prepared surface, mix in by palce method at OMC and compacting with Vibratory Roller to achieve the desired density including all labourcharges etc, complete as per technical specification and as directed by the departmental officers. Morth - Rev V No. 111.112.401.900
147.5
-
-
Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications.
147.7
-
-
Supplying and laying precast Rubber Moulded hydraulically pressed cement concrete paver block with pattern design of 50% colour and 50% Plain made of M40 grade concrete 63 mm thick of approved quality and colour, over the filling manufactured sand to 50 mm thick, levelling and compacting with plate vibrator anال laying of the inter locking paving blocks with sand binding and final compaction with plate vibrator of 3 tonne capacity finishing the surface including cutting of blocks at the edges including all labour, materials transportation, shifting etc., complete, as directed by the Engineer-in-charge.
916
-
-
Supplying and laying of flooring with quality approved make Ceramie Tactile Tiles (seamless joint) confirming to 15 13006/EN 176 Group Bia with technical specification as Mehs scratch hardness minimum 7. Water Absorption of less than 0.5%, Modulus of Rupture greater than 15 N/mm2, Deep Abrasion resistant maximum 175 mm 3 Surface flatness, Straightness of sides & 0.25%, thickness + 5% of size of approved colour and size & thick as specified below, set in 20mm thick C.M.14(1 cement and 4 manufactured sand) and pointing with white cement to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, work at all levels and as directed. Rate shall be inclusive of forming pattern as directed by Engineer-in- charge. ete; as complete in all respects and complying with relevant standard specifications and as directed
8
-
-
Providing And Laying of Hot Applied Thermoplastic Compound 2.5 mm Thick Including Reflectorising Glass Beads @ 250 Gms Per Sqm Area, Thickness of 2.5 mm Is Exclusive of Surface Applied Glass Beads As Per Irc:35 The Finished Surface To Be Level Uniform And Free From Streaks And Holes Etc Completed As Per Mort& H Specification No.803
805
-
-
Providing And Fixing Reflective Road Studs of Category a Raised Pavement Markers Made Out of Poly Carbonate / Methyl Methecrylate /Abs Moulded Body Conforming to astm D 788 And Reflective Panels With Micro Prismatic Lens Capable of Providing Total Internal Reflection of The Light Entering The Lens Face With Retro Reflectance And Chromaticity Values Conforming to astm D4280. The Reflective Raised Pavement Markers Shall Also Confirm To The Morth Circular No Rw/Nh. 33023/10/97- Do.lii Dt 11.06.97. The Height, Width And Length Shall Not Be Less Than 15mm, 90mm And 100mm And With Minimum Reflection Area of 13 Sq.m On Each Side And The Slope To The Base Shall Be 35+/-5Degree Each Reflectors Shall Have A Cil Not Less Than Values Specified In Table 2 of Said Morth Circular.
-
-
-
The Strength of Deteachment of The Integrated Cylindrical Shanks, (of Diameter Not Less Than 191 2mm And Height Not Less Than 10+/-2mm) From The Body Is To Be A Minimum Value of 500kgf Fixing Will Be By Drilling Holes On The Road For The Shanks to Go Inside, Without Nails And Using Epoxy Resin Based Adhesive As Per Manufacturer's Recommendation And Complete As Directed By The Engineer The Marker Shall Support a Load of 13635Kg Tested In Accordance With Astm D4280 And Confirming to tre 35-2015 Guidelines And 2 Year Manufacturers Warranty For The Satisfactory Field Performance To Be Submitted To The Engineer Incharge For Payment Processs As Mort&H Specification 804 Etc Complete
207
-
-
Providing and fixing of Delineator as per IRC 79- 2019(road way indicators, hazard markers and object markers) consisting of minimum retro reflective unit exposed area of 330 cm2 white color, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 2012 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table specification. The delineator shall be painted with powder coat of minimum 40 microns thickness, on top of which retro reflective sheeting shall be pasted on both sides. The structure shall be manufactured in roll forming process and shall have height not less than 800 mm above the ground, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed.
-
-
-
The front and back faces of the delineator should be curved with a radius of not more than 200 mm and with delta angle (or central angle of curve) lying between 20 Deg and 30 Deg, to increase the visibility of the delineator for vehicles moving in continuous curves. The delineator shall have grooves across the length to make the reflective sheets vandal-proof. The delineator is meant for application on gaps in median, traffic islands, dangerous bends, roundabouts, narrow bridges etc. or as desired by site engineer with a period of one year warranty,
3
-
-
Providing and Fixing of Flexible Median Markers as per IRC 79-2019 shall be provided with fluorescent yellow colour retro reflective sheeting Type XI as per IRC: 67 2012 Flexible Median Marker shall be of tough, high impact resistant, injection-molded, thermoplastic body with property of flexibility to provide high durability and U shape structure having rebound bounce back property. The body of FMM shall bounce back to its original position after 750 numbers of hits using pendulum of 1.8 Kg conforming to ASTM D 256. Height: The marker height shall be a minimum of 180 mm Width: The marker width shall be a minimum 120 mm Body Thickness: minimum of 6.5 mm Shank Length: Each of the shanks shall not be less than 20 mm and depth shall not be less than 30 mm. Reflective Area: Shall not be less than 90 Cm Square.
-
-
-
The sheeting shall be of Type XI as per IRC: 67 2012 and it should be on both the faces which provides maximum reflectivity at longer distance and is quite durable. The The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. Post installation the contractor shall obtain and submit a warranty Certificate from the product manufacturer in original for 2 years for the field performance of the product. Flexible Median Marker shall be fixed by a combination of epoxy adhesive and grouting/Drilling on concrete medians or properly constructed solid medians.
55
-
-
Reinforced Cement Concrete Bollards with M20 grade concrete and 150mm dia 4 Nos of 10mm dia TMT of overall size 800mm, 100mm projection of TMT Roads at the bottom of the Bollards beyond 800mm for anchor. Black pigment at 4.5 percent weight to cement will be used. Two Strips of Reflective 3M Sticker of width 40mm, including transportation and fixing charges etc. complete.
36
-
-
SIGNAGE
-
-
-
Providing And Fixing of Retro Refelctorised Cautionary 60 cm Circular Mandatory And Informatory Signs (With Definition Board) Made Out of High Intensity Prismatic Grade Sheeting Conforming To Type Standards of Ire 67: 2012 And Astm D 4956 Iv 09. Specification And Fixed Over 2mm Thick Aluminium Sheet Fixed Over A Back Supporting Frame of 25mm X 25mmx3mm. Mild Steel Angel And Supported on a Mild Steel Angel Post 75X75X6mm With A Clear Height of Not Less Than 2.10M From The Ground Level to The Bottom of The Sign Board And 0.60M Below Ground Level. The Sign Post Should Be Painted As Per Ire 67-2012 And Firmly Fixed To The Ground By Means of Properly Designed Foundation With M15 Grade Cement Concrete 45mmx45cmx60cm Size Including Cost And Conveyance of All Materials, Equipment, Machinery And Labour With All Leads And Lifts. Loading Charges Necessary For Satisfactory Completion of The Work As Directed By The Engineer-in-Charge
-
-
-
High Intensity Retro - Reflection Sheet Shall Consist of Minimum Coefficient of Retro-Reflection As Per Table 6.6 of Irc 67-2012. The Retro Reflection Sheeting Shall Be Covered Under 7 Years Warranty Issued For Field 6283.00 Each Performance And a Certified Copy of Three Years Outdoor Exposure Report Shall Be Obtained As Per 67:2012 (As Per MORTH Specification No.801)
5
-
-
Providing And Fixing of Retro Refelctorised Cautionary, 80 cm X 60 cm Rectangular Mandatory And Informatory Signs (With Definition Board) Made Out of High Intensity Prismatic Grade Sheeting Conforming To Type -Iv Standards of Ire 67:2012 And Astm D 4956-09. Specification And Fixed Over 2mm Thick Aluminium Sheet Fixed Over A Back Supporting Frame of 25mm X 25mmx3mm. Mild Steel Angel And Supported On A Mild Steel Angel Post 75X75X6mm With A Clear Height of Not Less Than 2.10M From The Ground Level To The Bottom of The Sign Board And 0.60M Below Ground Level. The Sign Post Should Be Painted As Per Ire 67-2012 And Firmly Fixed To The Ground By Means of Properly Designed Foundation With M15 Grade Cement Concrete 45mmx45cmx60cm Size Including Cost And Conveyance of All Materials, Equipment, Machinery And Labour With All Leads And Lifts. Loading Charges Necessary For Satisfactory Completion of The Work As Directed By The Engineer-in-Charge.
-
-
-
High Intensity Retro - Reflection Sheet Shall Consist of Minimum Coefficient of RetroReflection As Per Table 6.6 of lre 67-2012. The Retro Reflection Sheeting Shall Be Covered Under 7 Years Warranty Issued For Field Performance And a Certified Copy of Three Years Outdoor Exposure Report Shall Be Obtained As Per Ire 67:2012 (As Per MORTH Specification No.801)
1
-
-
Digitally Printed Retro-Reflectorized Overhead Gantry Informatory Sign Board of Size 12m * 1.8 m Providing and fixing of Digitally Printed Retro- Reflectorized Overhead Gantry Informatory Sign Board made out of cube corner Micro Prismatic grade sheeting of Type XI standards of IRC 67 2012 and ASTM D 4956 09 speciflCation, Digitally Printed using Latex Printer for traffic color logos / text and laminated with clear electro-cuttable film and applied to properly prepared sign substrates, fixed over 2 mm thick aluminum sheet with back supporting frame of size 50 mm * 50mm * 6mm MS angle and supported on 2 numbers of vertical posts of 300 NB (Nominal Bore) MS pipe of 12 mm thick with a ground clearance of 6metres along with 80NB Nominal Bore) MW Pipes with 4mm thick and 40NB (Nominal Bore) MS Pipes with 3.20 mm thick support posts.
-
-
-
The sign board should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed substructure and foundation with Reinforced Cement Concrete M20 grade column ( 1.25m * 1.25m * 1.90m) arid footing (1.8m * 1.8m * 0.3m) with Fe 500 steel over Plain Cement Concrete M15 grade levelling course of 100 mm thick for each vertical post, The minimum depth of foundation shall not be less than 2.00m. 1 number of MS Base plate of size 1200mm x 1200mm * 25mm with Anchor bolts of 25mm dia and 1000mm length, 2 numbers of MS Top plates of size 900 mm * 900mm * 16mm with suitable bolts, nuts and washers, suitable numbers of MS stifferier plates of 8mm thick are to be used for each vertical post, to hold the sign board at the bottom and top respectively including cost and conveyance of all materials, equipment, machinery and labour with all leads and lifts, loading charges arid fixing the overhead sign board in position, etc., for satisfactory completion of the work as per structural and foundation drawings approved by the competent authority and as directed by the Engineer-in-charge.
-
-
-
The micro prismatic grade retro-reflector sheet should bave minimum coefficient of retroreflection values as per Table 6.9 of IRC 67-2012. The retro-reflective sheeting shall be covered under 10 years warranty Issued Re tiel performance as per IRC 67-2012 and a certified copy of 3 years outdoor exposure report shall be sbtained. The warranty shall be inclusive of digitally printed logos text legends and their bonding to the retro-reflective sheeting (as per MoRT&H sperification No.80 13. The Latex printer used for digital printing should be used with inks of low VOC emissions and should have green guard, eco logo certificates as per UL 801 standards
1
-
-
Supply and fixing of M.S Grills for hand rail with one osat of Red oxide with Primer including all costs such as welting grinding and fabrication charges, cost and conveyance of all materials to site etc.complete as per standard specification.
2095
-
-
Electrical
-
-
-
Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, Outdoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars, internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps, internal wirings, Digital voltmeter and Ammeter and other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring. 1set of with TNEB Metering provision with sealing provision with 63A fuse 1 set and 63A TPN MCCB one of neutral link and all other connected accessories etc,. asper IE norms.
For all items in this section, the rate includes necessary supports as required at site. No extra payment will be made for the same. Rate shall inclusive of factory witness test and all accessories, breakers , control wiring, models has to be followed as per in the technical specification.
1
-
-
Supply, erection, earthing, testing and commissioning of the following MCB DB's IP 65 / Weather proof Protection Double Door type with powder coated including all interconnections and accessories like bolts, nuts and associated civil works, etc; The rate shall be inclusive of necessary cable/conduit adopter boxes for IN and OUT wiring.
12 W TPN Outdoor DB - ( External Lighting - Outdoor type with suitable Pedestal frame with lock and key )
Supply,Erection, Testing and Commissioning of the following Type feeder pillar enclosure with MCCBs / MCBs /ELCBs, / Timer and contactor manufacturer's sheet 16SWG enclosure for with provision for cable entry boxes, with Outdoor application as specified Protection, fixed on the floor with all interconnections and accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth as per the Corporation/ Highway department requirement.
Incomer 125 A TPN MCCB with Timer control On/OFF 63 TP MCB + ELCB/RCCB - 12 Nos :
12W TPN Outdoor DB.
The rate includes necessary connected minor civil works if required and necessary pedastal supports as required at site. No extra payment will be made for the same. The rate shall be included to fixing the DB where as in concealed / or open as per site condition.
1
-
-
Supply and installation of 16M high mast shaft in two sections suitable for 50 m/sec wind speed, with head frame, winch mounting bracket, luminaries carriage suitable to install 8-12 nos luminaries (Semi- circle arrangement) with counter weight arrangements , mounting clamp and brackets etc. Raising ,lowering system comprising double drum winch, suitable SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lighting final, Lightning spike if require, wiring material from JB to individual luminaire & MCB in base compartment are included and are a part of the installation, foundation bolts manufactured from special steel along with nuts, washers, anchor plate, and common template. LED Single dome aviation obstruction light, outdoor stand-mounted feeder pillar with 63A 4pole RCCB with 100mA, single dial time switch, 45A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and outgoing 25 & 4.0 sq. mm terminals, shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour, GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour(2nos per mast required) , wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm, lugs, MCB and all labour,mast feeder pillar by grouting the stand in concrete. with all necessary components required etc.
1
-
-
Supply, erection, testing and commissioning of 8 mtr free standing Single arm bracket 8 sided octagonally continuosly tapered strcutured pole with base plate of size 300 x300 x 12mm as per IS- 875 along with 120W LED fitting with following specification.
Bottom pole dia -130mm Top Pole dia -70mm Thickness of pole -3mm.
The pole should be hot dip galvanized confirming to BESN ISO - 1461 with thickness of 65 Micron. Construction of pillar accommodating MCB and switch housed in weather proof box including wiring to the light fittings with 2 runs of 2.5 Sq.mm PVC insulated copper conductor, supplying and fixing 4 way 30 A rated terminal block loop in loop out cable arrangements coil earthing etc. the rate shall included for cable in and out throught pipe.The pole shall be as required by the Engineer in charge and complete with suitable pressure die cast aluminum housing also adhering to the above said specifications.Note:-The rate shall be quoted for complete set of Pole, Base foundation,Anchor fastener,internal wiring,earting materials,6A DP MCB box and all necessary accessories and civil cost etc should be provided as suitable to the requirement.
14
-
-
Supply and Installation of the Traffic Signal Light either Red/ Green/ Yellow/ pelican crossing/ Pedestrian crossing signal Source Power◻192 LED
Voltage◻220 V Lighting type◻LED
Diameter (inch)◻100 or 200 or 300mm
Specifications:
Insulation Resistance: 2m Frequency Deviation: ±0.2MHz
Voltage: AC 220 V
2
-
-
Supply and Installation of the Traffic light pole Galvanized Iron (GI) Octagonal Traffic Light Pole
Material Galvanized Iron (GI) Pole Height 35 feet
Type Single Arm Length 5 meter
Section Shape Octagonal Surface Treatment Galvanized
Technique ERW . The rate includes excavation of Earth, Filling of 15cm sand, Cost of bricks and refilling of sand.
1
-
-
Providing and fixing of LED Blinkers dia 300 mm,24 hours operation,with adapter 12v dc connected 1.5 sqmm copper cable , guarded with 3/4 pvc pipe connected taken into the power source near by distribution box and the led blinkers fixed into clamp to the pole dia 65 nb pole height 4.2 mtrs MS pole with auto coat paint .Foundation with M15 grade cement 600X600X800 mm below ground level .
10
-
-
Supply & laying of 3-1/2 x 25 sq.mm. PVC LTUG Al armoured cable. cable trench / clamping wall / pvc duct with suitbale clamps.
350
-
-
Supply & laying of 3 1/2 x 50 sq.mm. PVC LTUG Al armoured cable. cable trench / clamping wall / pvc duct with suitbale clamps.
150
-
-
Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC LTUG armoured cable with earth connection.
2
-
-
Supply and fixing of brass cable gland for the 3 1/2 x 50 Sqmm PVC LTUG aluminium armoured cable with earth connection
2
-
-
Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable)
2
-
-
Supply and providing cable end termination of 3 1/2 x 50 Sq.mm..AL Arm.XLPE FRLS Cable. with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum.
Cable)
2
-
-