Chennai Metropolitan Development Authority Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Development Authority Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Dec 2024
Closing Date16 Dec 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Brick Masonry in cement mortar walls under 3m high

75

-

-

... More
Providing and constructing cast in situ hydraulic bored piles of 450mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).

3659

-

-

... More
Providing UNDER REAMED PILES R.C.C.30cm (12") dia cast-in-situ with single reamed (bulb) in cement concrete 1:1.5:3, 11.5cm above G.L. including boring, erecting, vibrating,curing, hire charges for drilling equipments, etc.,complete as per relevent ISI specifications(excluding cost steel reinforcement).

315

-

-

... More
Carrying out initial Working pile load test on specified dia piles as specified in IS:2911 (Part 4). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete.

-

-

-

... More
Initial Load Test

1

-

-

... More
Dynamic Load test

2

-

-

... More
integrity Load test

2

-

-

... More
Earth Work Excavation and deposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay stiff black cotton soil, hard red earth, shales, muram, gravel, stony earth and earth mixed with small boulders etc., as per SS 20B excluding hard rock requiring blasting etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers.

1510

-

-

... More
Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers.

226

-

-

... More
Providing and Laying PCC 1:4:8 (1 of Cement, 4 of M-Sand and 8 of graded metal) using 40mm metal including cost and conveyance of all materials mixing, laying, compacting, curing etc., complete and as directed by the dept. officers.

132

-

-

... More
Providing Granolithic floor finish 50mm thick with PCC 1:2:4 (One cement two M-sand and four aggregate) using 10 to 12mm thick HGB jelly and river sand and including rubbing the top surface smoothly thread lining if found necessary and curing etc., complete complying with standard specification and as directed by the Departmental officer

706

-

-

... More
Supplying and filling in foundation, basement, etc with filling Gravel in well rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.

882

-

-

... More
Laying of Damp Proof Course in Basement floor finish level including cost of material and labour charges etc., complete

706

-

-

... More
Supplying and Erecting Centering for Sides and Soffits including necessary supports and strutting up to 3.29 M height for plane surface as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90cm centre to centre and supported by casuarina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specification and as directed by the departmental officers.

-

-

-

... More
For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, Portico slabs and beams, etc.,

7203

-

-

... More
For column footing plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,

678

-

-

... More
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.

880

-

-

... More
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc

1951

-

-

... More
Post Tensioning Work: Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concreting &,reinforcement steel which shall be payable under respective items separately.

3

-

-

... More
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. Rate to include all leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge

-

-

-

... More
For Foundation and Basement

318

-

-

... More
For Ground Floor

283

-

-

... More
For First Floor

284

-

-

... More
For Second Floor (First lift- upto 4.50m Height)

61

-

-

... More
For Second Floor (Second lift- above 4.50m Height)

270

-

-

... More
Terrace floor

48

-

-

... More
Supplying, fabricating and placing in position of MS/RTS Rods for grills for all RCC works including bending, tying grills and placing in position including cost of steel, binding wire etc., complete and as directed by the departmental officer.

399000

-

-

... More
Flyash Brick Work in CM 1:5 [One of Cement and Five of M-Sand) 230mm thick Using size 230x110x75mm including dewatering wherever necessary proper setting, curing etc., all complete and as directed by the departmental officers.

-

-

-

... More
For Foundation and Basement

79

-

-

... More
For Ground Floor

212

-

-

... More
For First Floor

202

-

-

... More
For Second Floor (First lift- upto 4.50m Height)

175

-

-

... More
For Second Floor (Second lift- above 4.50m Height)

110

-

-

... More
For Terrace

60

-

-

... More
Flyash Brick Partition Wall in CM 1:3 [One of Cement and Three of MSand) 110 mm thick Using of size 230x110x75mm foundation and basement including both side plastering with C.M 1:5, 12mm thick, dewatering wherever necessary proper setting, curing etc., all complete and as directed by the departmental officers.

-

-

-

... More
For Ground Floor

59

-

-

... More
For First Floor

47

-

-

... More
Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails.

-

-

-

... More
Upto 3 M Height

340

-

-

... More
For every additional height of 2.5 M (3m - 5.50m)

340

-

-

... More
For every additional height of 2.5 M (5.50m -8.00m)

340

-

-

... More
For every additional height of 2.5 M (8.00m -10.50m)

114

-

-

... More
For every additional height of 2.5 M (10.50m -13.00m)

114

-

-

... More
For every additional height of 2.5 M (13.00m -15.50m)

114

-

-

... More
For every additional height of 2.5 M (15.50m -18.00m)

114

-

-

... More
For every additional height of 2.5 M (18.00m -20.50m)

56

-

-

... More
Special ceiling plastering and finishing all RCC exposed surfaces such as RCC slabs, sunshades, canopies, stair case steps, landing slabs etc with CM 1:3 (One cement and three Plastering sand) 10mm thick including hacking the surfaces and providing necessary CM nosing, beading as per size specified wherever necessary using the same mix etc., complete complying with standard specification and as directed by the Departmental Officer

723

-

-

... More
Plastering the External walls with Cement Mortar 1:5 20 mm thick using the Plastering sand including curing and finishing neatly complying with standard specification and as directed by the departmental officers etc. complete.

2896

-

-

... More
Plastering the Internal walls with Cement Mortar 1:5 12 mm thick using the Plastering sand including curing and finishing neatly complying with standard specification and as directed by the departmental officers etc. complete

6517

-

-

... More
Painting the walls with Two coats with first class quality Plastic Emulsion paint of approved colour over a priming coat including thorough scraping,clean removal of dirt. The rate includes cost of brushes,sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer(the colour and quality should be got approved by the Executive Engineer before use)

5330

-

-

... More
Supplying and painting the Ceiling with two coats of cement paint as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work)

723

-

-

... More
Painting the outer walls with Two coats with first class quality Exterior Emulsion paint of approved colour over a priming coat including thorough scraping,clean removal of dirt. The rate includes cost of brushes,sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer(the colour and quality should be got approved by the Executive Engineer before use)

2896

-

-

... More
Laying the Kota Stone slab Flooring with new Kota stone of 20 mm thick both side machine polished edge and machine polished cutting for flooring using CM 1:3 (one cement three Msand) including labour for fixing in position etc., complete complying with standard specification and as directed by the Departmental Officer

156

-

-

... More
Laying Cuddapah slab Flooring with new cuddapah slab of 50 mm thick both side machine polished edge and machine polished cutting for flooring using CM 1:3 (one cement three sand) including labour for fixing in position i etc., complete complying with standard specification and as directed by the Departmental Officer

3

-

-

... More
Paving the floor with Marble slab 18 mm thick of approved quality over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with same cement mortar without any air gap in the slab neatly and polishing, curing, fixing in position as per standard specifications and as directed by the departmental officers. The quality of slab should be got approved by the Executive Engineer before use on work.

842

-

-

... More
Supplying and laying of Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

621

-

-

... More
Laying Texture tile for lift facia of 20 mm thick both side machine polished edge and machine polished cutting for flooring using CM 1:3 (one cement three sand) including labour for fixing in position i etc., complete complying with standard specification and as directed by the Departmental Officer

53

-

-

... More
Flooring with following Designed antiskid ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)

223

-

-

... More
Dadooing walls with following best approved quality, Designed colour ceramic tiles of sizes300mm x 450mm x 8mm thick in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.

925

-

-

... More
Supplying & Fixing of MS Grill including cost of materials, cutting, welding and fixing Charges etc., all complete and as directed by the departmental officers.

4840

-

-

... More
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost fpriming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

257

-

-

... More
Weathering course-using Concrete broken brick jelly 20 mm gauge in pure slacked lime (No sand to be used) over RCC roof slab. The proportion of broken brick jelly to slaked lime being 32:12½ cft well beaten by wooden beaters for giving required slope and thickness required etc complete complying with standard specifications and as directed by Departmental Officers.

112

-

-

... More
Finishing the top of roof with one course of machine pressed tiles of size 23x23x2cm of approved quality laid in CM1:3 (one cement and three M-sand) mixed with 2% of water proofing compound by weight of cement used and pointed with the same oiled mortar including mixing of red oxide etc complete complying with stadard specifications and as directed by Departmental Officers.

775

-

-

... More
Supplying And Fixing Rubber Moulded Interlocking Blocks Against Available Edge Restraints 80 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (MSand)).

851

-

-

... More
Best Indian Teak Wood Panelled door in double shutters with sideframes only. The size of frames shall be 60x75mm fixed with 6Nos.of iron hold fasts. The shutters shall be of 40mm thick with moulded panels in 20mm thick planks with 6Nos.of butt hinges100mm long.1No.of iron padlock 15cm long 1No.of iron tower bolt15cm long for locking arrangements including fixing inposition,etc.,complete.(ISI STD)

31

-

-

... More
Supplying and fixing single leaf flush door 32/30mm thickness both side commercial ply and approved brand with T.W.frames of size 100x75mm at side verticals and top,6Nos.of iron hold fast fixed in C.C.1:2:4 and 3Nos.of butt hinges 125mm long including wind appliances furniture iron fittings 2Nos.of iron pad lock 15cm long for locking arrangements and fixed in position as directed during execution.(ISI STD)

34

-

-

... More
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)

61

-

-

... More
Fabricating Supplying and fixing in position of Aluminium anodized Powder Coated finish Two panels openable type window in all floors with aluminium sections of the Outer frame: 37.70x33x2mm @ 0.50 kg/m,Centre mullions:59x33x2.50mm @0.936 kg/m,Shutter frame : Z section 24.50x 33x 3mm @ 0.525kg/m,Aluminium clips:0.109 kg/m with neccessary accssories such as rubber beadings, special hinges, handle including supplying and fixing 4mm thick plain glass including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column slab, masonry walls wherever necessary with power drills to the required extent and make good to the original conditons after fixing and also as directed. All the Aluminium sections are to the anodised with Powder Coated finish under electrically controlled conditons in accordance with Is 1868/1962 for an average anodic film thickness of 15 microns.

197

-

-

... More
Supplying, fabricating and fixing inposition Aluminium anodised natural colour matt finish louvered ventilator of with outer frame section with 62x38x2mm at 1.174 kg/m and the louvered with moving arrangements made with aluminium channel of size 60x30x4mm @ 1.274 kg/m ALuminium clips 19.05x17.27/ 11.05x0.075mm @ 0.169kg/m with necessary 4mm thick plain glass panel for louvers including cost of all materials, labour and power required for fabrications, chipping dismantling making holes in RCC, masonry and made good to the original condition after fixing etc., complete. The Aluminium surface is to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of notless than 15 Microns,etc., complete.

7

-

-

... More
Solid PVC Door Shutters using 19 gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigitdly fixed in position including necessary furniture and fittings. The over all size of styiles shall be 50mm x 30mm. The over all size of top rail, Lock and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.

16

-

-

... More
Supplying and fixing in position of aluminium handrails anodised Powder coated finish c type section of size 70x30x3 mm thick at 1.527 kg/m with all alu. Strip section No.5126 of 37 mm with 0.227 kg/m inclulding balustrades square section of size 25.40x25.40x1.50mm thick at 0.442 kg/m to a height 800mm from the finish floor level at step nesing fixed at 150mm intervals iln the two numbers for each step with necessary screws plugs etc. including providing holes iln the RCC masonry steps landing or floor and also fixing the aluminium depth and grouted with cement and redoing the damaged portion as original condition.

67

-

-

... More
Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of single leaf fully panelled sliding door with 12mm thick bothside prelaminated partile board at the Shutter bottom rail:100x44.45x2.50mm@1.974 kg/m,Top & Verticle 50x44.45x2.50mm @ 1.292 kg/m,Lock rail 50x44.45x2.50mm @ 1.292 g/m, Running channel section:50x44.45x2.50mm@1.292 kg/m, and necessary accessories such as Alu.clips 17.15x17.27x1.50mm @ 0.176 kg, Alu handle 100x30mm @ 0.988 kg/mfull length of handles on both sides, lock, roller, including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and waking hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete. All the Alu. sections are to be anodised. etc., complete

15

-

-

... More
Supply and applying water proofing treatment on Retaining walls external surface at Basement, UG Sump, Water tank, Raft sides etc. using cement admixed with water proofing compound in the following order. i) Making ' V ' grooves at the construction joints of size 20 x 20 mm and filling the "V" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cement ii) Supply and Fixing of 50 long 18 mm dia GI nozzles in the hole of about half the depth of member size along construction joints, and honey comb areas at a spacing not more than 1m c/c. iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement. iv) Sealing & cutting of nozzles and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1 by weight.

2356

-

-

... More
v)Supply and applying one coat of TAPECRETE Acrylic Polymer Modified Cementitious Slurry Coat over well prepared surface as a Primer and applying CICO CORCHEM 206 - I Polyurethane Based Elastomeric Coating to the thickness of 1.5 mm in 2 coats over TAPECRETE slurry coat applied surface. vi) Lay protective plaster layer with 12mm thick Cement Mortar 1:4 (1 cement: 4 coarse sand) admixed with Normal setting integral Waterproofing compound CICO NO.1 or approved equivalent conforming to IS 2645 at the rate of 2% by weight of cement over the third coat of brush topping. Plaster shall be cured by spraying of water for the next 7days. The entire water proofing system shall be protected with a 25 mm thick extruded polystrene with necessary low VOC adhesieve.

-

-

-

... More
Elevation work for the front wall Providing Glass Fibre reinforced Panel using of Sizes for -1525x750x25mm, 1830x750x25mm and ribbed panel a precast panel and installed at site by using scaffolding , fly ash brick and roof projection nib will act as a holding member in the exterior facade .Anchoring screw will hold on four corners of a GFRC Panel using Curved Wall Panels and ribbed panel including cost of materials, labour charges etc., complete

-

-

-

... More
Curved wall panels (1525 x 750x 25 mm)

250

-

-

... More
Curved wall panels (1830 x 750x 25 mm)

400

-

-

... More
Ribbed Paned

185

-

-

... More
Painting the wall with Texture Finish Paint of approved colour over a priming coat including thorough scraping,clean removal of dirt. The rate includes cost of brushes,sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use)

1271

-

-

... More
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre ‘T’. The ‘T’ shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of ‘T’ section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of ‘T’ section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile ‘L’ Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look

1067

-

-

... More
Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proofplywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete

749

-

-

... More
Providing and fixing Acoustic Wall Panelling (equivalent to Armstrong) in channelled wood works perforated panels of width 192mm, thickness of 15mm and length of 2400mm or as per required by the Departmental Engineer made of a high density fibre board with minimum 725 kg./m3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special peforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non woven acoustical fleese having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Engineer-in-Charge.

1357

-

-

... More
Installation: Install aluminium box section (provided by others) of section 50mm x 25mm or as approved by the Engineer-in-Charge on the solid wall horizontally using screws and plugs at spacing of 600mm centre to centre. Screw the aluminium extruded keel for channelled wood works provided by Armstrong over the lowest and second aluminium section at an on centre distance of 600mm. Place the inside clip on the groove end of the panel along the aluminium keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour (provided by others). Installation to be carried out by Armstrong Trained Installation Team and installation should be carried out as per Armstrong Recommended Procedure.

-

-

-

... More
Providing band course work flat 12mm thick and 100mm deep withcement mortar 1:3 (1 cement and 3 Crushed Stone Sand (Commercially called M-Sand)) including rendering smooth,curing, etc., complete as directed during execution.

32

-

-

... More
Conveyance of Earth/Debris to a lead of within 30 km from site as directed by the Engineer inculding loading, unloading, hire charges for vehicle and other incidental charges etc., all complete as directed by the Departmental Officers.

1620

-

-

... More
Landscape

-

-

-

... More
Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth.

33.12

-

-

... More
Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost)

33.12

-

-

... More
Supplying and Planting of Raphis palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10' height,including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge

90

-

-

... More
Planting of Dracena mahatma ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge

100

-

-

... More
ELECTRICAL

-

-

-

... More
Supply and fixing of 400 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with PWD earthing.

1

-

-

... More
Supply and fixing of 7 segment 8 way 63A TPN MCB sheet steel distribution board (Higher end) with metal /acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only. 63A 4P MCB - 1 no. 63A 4P 30MA RCCB/ELCB - 1 no. 63A DP MCB Isolator -3 nos. 6A to 32A SP MCB - 24 nos.

3

-

-

... More
Supply and fixing of 12 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB switch as incoming and 4 nos. 32A 3P MCB, 24 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 100 A 4P MCB switch - 1No. 32 A 3P MCB switch - 4 Nos. 6A - 32A SP MCB switch - 24 Nos.

1

-

-

... More
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 3 nos. 32A 3P MCB, 18 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End 100 A 4P MCB switch - 1No. 32 A 3P MCB switch - 3 Nos. 6A - 32A SP MCB switch - 15 Nos.

1

-

-

... More
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4P MCB Isolator as incoming and 4 nos. 32A 3P MCB, as outgoing in flush with wall with earth connection only. Higher End 63 A 4P MCB switch - 1No. 32 A 3P MCB switch - 4 Nos.

1

-

-

... More
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End

1

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End

265

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )

50

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End

55

-

-

... More
Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End

12

-

-

... More
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End

25

-

-

... More
Wiring with 2 x 4 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitablePVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil) Higher End

25

-

-

... More
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion

1500

-

-

... More
Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.

750

-

-

... More
Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion

50

-

-

... More
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position.

50

-

-

... More
Supply and Run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour.

50

-

-

... More
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End

25

-

-

... More
Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End

10

-

-

... More
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End

30

-

-

... More
supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")

47

-

-

... More
supply and fixing of 450mm Sweep wall mounting fan

16

-

-

... More
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall

17

-

-

... More
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan

17

-

-

... More
supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.

57

-

-

... More
supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting.

39

-

-

... More
supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.

10

-

-

... More
Supplying and fixing 20W 4 Feet LED Fitting with LED

60

-

-

... More
Supplying and fixing of LED Flood Light 100W with Integrated Driver

4

-

-

... More
Supplyandlayingof3.5x240sq.mmPVCarmouredLTUGcableinatrenchtobeexcavatedatadepthof0.75metreputting0.15metrelayerofsandandcoveringthecablecompletelywithbricksandsandandrefillingtheearthtomake good

100

-

-

... More
Supplyandlayingof3.5x185sq.mmPVCarmouredLTUGcableinatrenchtobeexcavatedatadepthof0.75metreputting0.15metrelayerofsandandcoveringthecablecompletelywithbricksandsandandrefillingtheearthtomake good

80

-

-

... More
Supplyandlayingof3.5x120sq.mmPVCarmouredLTUGcableinatrenchtobeexcavatedatadepthof0.75metreputting0.15metrelayerofsandandcoveringthecablecompletelywithbricksandsandandrefillingtheearthtomake good

75

-

-

... More
Supply and Laying of 4 x 16 sq.mm. PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.

290

-

-

... More
Supply and Laying of 4 x 6 sq.mm. PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.

350

-

-

... More
Supply and clarnping of 3.5 x 35 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps

125

-

-

... More
Supply and clarnping of 3.5 x 120 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps

50

-

-

... More
Supply and clarnping of 3.5 x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps

85

-

-

... More
Supply and clarnping of 4 x 16 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps

100

-

-

... More
Supply and clarnping of 4 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps

150

-

-

... More
Supply and clarnping of 3.5x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps

50

-

-

... More
Supply and fixing of brass cable gland for 3-1/2 x 240 sq.mm. PVC armoured LTUG cable with earth connection

4

-

-

... More
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection

6

-

-

... More
Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection

4

-

-

... More
Supply and fixing of brass cable gland for 4 x 25 sq.mm. LTUG armoured cable with earth connection

16

-

-

... More
Supply and fixing of brass cable gland for 3-1/2 x 35 sq.mm. PVC armoured LTUG cable with earth connection

4

-

-

... More
Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection

2

-

-

... More
Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete

4

-

-

... More
Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete

6

-

-

... More
Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete

2

-

-

... More
Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete

4

-

-

... More
EarthingaspertheISIspecificationwithanearthelectrodeof2.10metreClass'B'GIpipeofdianotlessthan40mmwithcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnelingarrangementswithnecessarymasonry work and with 38mm RCC cover slab for the brick masonry

8

-

-

... More
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection

200

-

-

... More
Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection

50

-

-

... More
Supply and Run of 1 of No.8 SWG copper wire for earth connection

450

-

-

... More
Supply and fixing of 4Mtr height K-lite Navira pole with single arm 1 x 90W LED Street light luminaire (IP65). The following specifications are, System wattage : 90w LED Integral Driver : constant current Input voltage : 230-240V Dimensions : 464mm (Length) x 310mm (Height) x 214mm (Width ) Power factor : 0.95 Surge Protection : 6KV Material : Mild steel (MS) Diffuser : Clear polycarbonate optical cover Colour Temperature : 5700K Colour : Grey. The rate includes necessary foundation etc., complete.

15

-

-

... More
Supply, Erection, Testing and Commissioning of 200KVA Diesel Generator set with AMF control panel, comprising of Water cooled CPCB IV+ developing @ 1500 RPM and Alternator, complete with type approved canopy and all accessories. with the following technical specification: *Industries most reliable engines, proven over decades. *Low emission, High efficiency. *Compact, robust and rugged design. *Engine Dry type air cleaner *Exhaust Silencer (Residential type) Hospital Grade. *Expansion bellow *Lube oil cooler Lube oil filter (“Spin-on” type) *Fuel Filter (“Spin-on” type) *In line mono block fuel injection pump with Electronic Governor and fuel feed pump. *Dynamically balanced Flywheel with starter ring *Electronic Governor :Governing class G2(as per ISO 8528 part V) *SAE 1 flywheel housing and flywheel suitable for SAE 14 disc coupling for close coupling of single bearing alternator.

-

-

-

... More
*Exhaust gas turbocharger 24 Volt electric starter motor 24 Volt, 18 amps. Battery charging alternator *Engine instrument control panel consisting of: Engine safety module EMS (KG934) with built in On/Off Bush button. ALTERNATOR 200KVA, Three phase 415V, 0.8 pf 4 wires 50 hz at 1500 RPM brushless alternator. The voltage regulation will be 2 phase sensing +/¬ 1 %. The alternators shall be of Class H insulation, enclosure IP 23 and are designed built and tested to IS 4722 or any other equivalent Indian or international standards. Control Panel: 200 KVA DG Set Std Control Panel Consisting of EMS KG934 unit consisting Volt, Amps, RPM, Hz, LLOP, HWT, Low fuel level, over Speed alarm, Over Load alarm, Load imbalance safety alarm, etc. Fuel Tank: 300 Letters Capacity inbuilt Fuel Consumption: 100% = 37.6 Litres/hr.75% = 27.6Litres / hr.50% = 19.8Litrs/hr. Battery: 24V DC, 130AH Supply of AMF Control Panel Suitable for 320 KVA DG set for EB Services with byepass arrangement. (Make: Kirlosker, Koel or equvalent)

1

-

-

... More
CT METER BOARD Supply and erection of compart mentalised CT metering panel (3 Compartment type) for receiving the EB supply consisting of 400A 4 Pole copper bus bars suitable to accommodate 3 Nos. CT's. The meter chamber will have provision to fix 3 phase 4 wire 50 HZ CT operated Kw/hr meter to be supplied by supply authorities and the front meter door shall be fitted with glass /Acrylic cover in front of meter dial to read the meter recording the meter door shall have provision for sealing arrangement by supply authorities. The TTB chamber will have 3 phase 4 wire 50 HZ TTB. All chambers should have sealing arrangement provision. 3 Nos 400 Amps Porcelain cut-outs and 500 Amps Neutral link with cable chamber suitable for receiving 1 no. 3 1/2 core 240 sq mm PVC insulated Aluminium conductor armoured cable. The board should be manufactured such that should be approved by Local supply authorities.

1

-

-

... More
MAIN PANEL Supply, erection, testing and commissioning of floor mounting free standing dust & vermin proof cubicle pattern switch board fabricated out of 14 /16 SWG CRCA sheets comprising of following for MAIN LT PANEL. EB INCOMING 1 No.- 400A,4P,50KA MCCB with Micro Processor based over current, short circuit with Electrically operated with electro mechanical interlock and A/M SS along with a controller for sensing and switching ON-OFF depending on the available source and also switching ON /OFF depending the load requirement either locally or from remote. The breaker should be provided lockable local /remote switch with switching ON/OFF of breaker either locally or from BMS indicate the switch status. The MCCB shall be fitted with miniumum of 1 NO +1 N/C spare contacts for external linking in addition to the required number of N/O, N/C contacts for use of Interlocking & indication trip device.. An instrument chamber comprising of the following shall also be provided for each incomer. DIGITAL type flush mounting load manager having to indicate the following parameters.

-

-

-

... More
1 No. - Digital type flush mounting Multifunction Meter with inbuilt selectors to indicate the following parameters with RS 485 Current, Voltage, KW, KWhr, Power factor, Frequency, etc. Sensing, indication & tripping arrangement for demand power arrangement etc.. 4 Nos. - 400/5A Class 0.5, 15 VA C.T. metering.(ND-1) 3 Nos. - 400/5A Class 0.5, 15 VA for power factor sensing relay1 Set. - 3 Nos. R, Y, B indicating lamp to indicate supply position.1 Set. - 2 Nos. Red & Green indicating lamp to indicate ON-OFF position of breaker.1 Set. - Amber Breaker trip due to fault indication 1 Set - Potential protection HRC fuses/MCB of suitable rating for indicating lamp, meter, control circuit etc.1 Set. - Outgoing terminals to receive Cables. 1 Set . - 50KA Class 1 & 2 Surge Protection Devices with HRC Fuse.

-

-

-

... More
DG INCOMING 1 No.- 400A,4P,50KA MCCB with Micro Processor based over current, short circuit with Electrically operated with electro mechanical interlock and A/M SS along with a controller for sensing and switching ON-OFF depending on the available source and also swithcing ON /OFF depending the load requirement either locally or from remote. The breaker should be provided lockable local /remote switch with switching ON/OFF of breaker either locally or from BMS indicate the switch status. The MCCB shall be fitted with miniumum of 1 NO +1 N/C spare contacts for external linking in addition to the required number of N/O, N/C contacts for use of Interlocking & indication trip device.. An instrument chamber comprising of the following shall also be provided for each incomer. DIGITAL type flush mounting load manager having to indicate the following parameters. 1 No. - Digital type flush mounting Multifunction Meter with inbuilt selectors to indicate the following parameters with RS 485 Current, Voltage, KW,KWhr, Power factor, Frequency, etc. Sensing, indication & tripping arrangement for demand power arrangement etc. 4 Nos. - 400/5A Class 0.5 15 VA C.T. metering.(ND-1) 3 Nos. - 400/5A Class 0.5, 15 VA for power factor sensing relay 1 Set. - 3 Nos. R, Y, B indicating lamp to indicate supply position. 1 Set. - 2 Nos. Red & Green indicating lamp to indicate ON-OFF position of breaker. 1 Set. - Amber Breaker trip due to fault indication 1 Set - Potential protection HRC fuses/MCB of suitable rating for indicating lamp, meter, control circuit etc. 1 Set. - Outgoing terminals to receive Cables. 1 Set . - 50KA Class 1 & 2 Surge Protection Devices with HRC Fuse.

-

-

-

... More
EB & DG INCOMING SHALL ELECTRICAL/ MECHANICAL INTERLOCK TO BE PROVIDED 1 - 400A TP & N Bus Bars with Alu. flat with the size having current rating of 0.7A / Sqmm. The bus bars shall be sleeved with colour coded heat be sleeved with colour coded heat shrinkable PVC sleeves with the exception of joint. The bus bars shall be supported at suitable intervel with SMC / FRP as per IS.OUTGOINGS: 2 Nos. - 250A TPN 36 KA MCCB with manual closing mechanism with Rotary handle, fitted with over current & Short circuit protection 1 Nos. - 200A TPN 36 KA MCCB with manual closing mechanism with Rotary handle, fitted with over current & Short circuit protection 1 Nos. - 160A TPN 36 KA MCCB with manual closing mechanism with Rotary handle, fitted with over current & Short circuit protection 2 Nos. - 100A TPN 36 KA MCCB with manual closing mechanism with Rotary handle, fitted with over current & Short circuit protection 8 Nos.- 63A 4P 10KA MCB as outgoings.

1

-

-

... More
Supply, erection, testing & commissioning of floor mounting dust & vermin proof cubicle pattern non compart mentalised APFCR Panel fabricated out of 14 /16 SWG CRCA sheet comprising of the following :- INCOMER: 1 No.- 160A TP & N 25KA MCCB with manual closing mechanism with Rotary handle, fitted with over current and short circuit protection and with 433V shunt trip releases Aux switch of 1 NO + 1 N/C for contacts multiplication etc. as incomer and provided with an instrument chamber having 1 - 8 stage APFCR Relay. 1 - Auto manual selector switch. 1 - Digital type flush mounting meter with inbuilt selector to indicate the following parameters suitable for operation with 5A CT secondary. Current, Voltage, Frequency 1 Set. - 3 Nos. R, Y, B indicating lamp to indicate supply position.1 Set. - 2 Nos. Red & Green indicating lamp to indicate ON-OFF position of breaker. 1 Set. - Amber Breaker trip due to fault indication 1Set - Potential protection HRC fuses/MCB of suitable rating for indicating lamp, meter, control circuit etc.

-

-

-

... More
OUTGOINGS: 1 No. - Capacitor compartment each with 100A TP 10KA MCB with FD kit, an auxiliary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 25 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 25 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 No. - Capacitor compartment each with 63A TP 10KA MCB with

-

-

-

... More
1 No. - Capacitor compartment each with 63A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 15 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 15 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
2 Nos. - Capacitor compartment each with 63A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 10 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 10 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 No. - Capacitor compartment each with 32A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 5 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 5 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 No. - Capacitor compartment each with 32A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 4 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 4 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 No. - Capacitor compartment each with 32A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 3 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 3 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 No. - Capacitor compartment each with 32A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 2 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 2 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 No. - Capacitor compartment each with 32A TP 10KA MCB with FD kit, an auxilary switch 1 NO + 1 NC, and suitably rated and having specific duty contactor with necessary bi-metal relays etc. all complete for control of 1 KVAr capacitors. ON - OFF push buttons, ON -OFF indicating lamp, provided with a 1 KVar capacitor bank with reactors, control wiring from the APFC relay all complete for proper operation of bringing in or out of the capacitors connected to maintain the Power Factor as stipulated by the supply authorities. As per details given.

-

-

-

... More
1 - 160A TP & N Alu. bus bar having a current density of 0.7A per Sqmm and with adequate number of FRP/SMC bus supports at suitable interval as per IS. The busbar shall be PVC sleeved with heat shrinkable colour coded PVC sleeves with the exception of joint.

-

-

-

... More
The instrument chamber meter /instruments shall be wired with 2.5 Sqmm for CT's &1.5 Sqmm for other circuits multi-strand copper conductor wire with double sleeving & with appropriate colour code and the terminal ferruled and connected with suitable lugs.

-

-

-

... More
The above panel shall be fabricated as per IS and complete with specified bus bar, bus supports, interconnections from bus to MCCB, MCCB to capacitor bank duly taped or sleeved wirings providing 2 Nos. earth bus with 25 x 6mm Alu. flat, door earthing with braided copper etc. all complete as per IS as acceptable to Architects in conformity with the Local Electrical Inspectorate whether or not all items has brought in this. The board shall be provided with noncompartmental and intercompartment shrouds, terminal extensions for receiving cable, shrouds for terminals etc. The aggregated capacity of each of the bank shall be of 50 KVAr. The board shall be finished with powder coated paint of approved shade after duly treated for rust prevention and applying 2 coats of metal primer. The board shall be provided with necessary warning, feeder designation labels as per IS and as per site requirement and cater to General requirement of switch board specification given in the tender.

1

-

-

... More
Supply of indoor wall mounting free standing dust & vermin proof cubicle pattern isolator/ starter panels with suitable cable adoptor boxes to receive incoming and outgoing cables with proper extended bus and cable supports.the scope shall include the necessry mounting/standalone hardweres.

-

-

-

... More
63A 4P 100mA RCCB with Outdoor Encloser

3

-

-

... More
100A TPN MCCB with Outdoor Encloser

1

-

-

... More
63A 4P MCB with Indoor Encloser

1

-

-

... More
AC PANEL -OUT DOOR TYPE Supply, erection, testing and commissioning of floor mounting Outdoor free standing dust & vermin proof cubicle pattern fire fighting panel fabricated out of 14 /16 SWG CRCA sheets comprising of following. INCOMER: 1No. - 250A TPN 36 KA MCCB with manual closing mechanism with Rotary handle, fitted with over current & Short circuit protection 1 No. - Digital type flush mounting power monitor with RS 485 with inbuilt selectors to indicate the following parameters Current, Voltage, KW,KWhr, Power factor, Frequency, etc. 3 Nos. - 250/5A Class 0.5 15 VA C.T. metering, 1 Set. - 3 Nos. R, Y, B indicating lamp to indicate supply position, 1 Set. - 2 Nos. Red & Green indicating lamp to indicate ON-OFF position of breaker,1 Set. - Amber Breaker trip due to fault indication, 1 Set. - Potential fuses/MCB for indicating lamps, meters, control circuit etc. 1 Set. - Outgoing terminals to receive Cables.

-

-

-

... More
OUTGOINGS: 2 Nos.- DOL Starter Compartement suitable for operation of upto 6 KW pump motor each comprising of :- 1 - 32A 4P MCB, 1 - Main contactor of suitable rating for operation of upto 6 KW motor. 1 - Local /remote sector switch, 1 - 2 NO + 2 N/C Auxilary conact for external linking duly wired upto terminal block. 1 - Green colour push button actuator with 1 NO + 1 N/C contact eliment for switching ON of motor locally. 1 - Red colour push button actuator with 1 NO + 1 N/C contact eliment for switching OFF of motor locally, 1 - Set of RED & GREEN ON-OFF indicating lamp. 1 - Set of Potential circuit fuses/MCB for control & indication, 1 Nos.- 100A TPN MCCB as outgoings, 4 Nos.- 63A 4P 10KA MCB as outgoings.

1

-

-

... More
S.E.T.C of surface mounting 1200mm length 40W LED batten type IP65 light fixture to be fitted in ceiling/wall as per site requirement with necessary frame, driver, interconnecting wires & fixing hardwares etc., Maximum Power consumption not more than 40W. (6000K)

10

-

-

... More
S.E.T.C of surface mounting 1200mm length 40W LED batten type light fixture to be fitted in ceiling/wall as per site requirement with necessary frame, driver, interconnecting wires & fixing hardwares etc., Maximum Power consumption not more than 40W. (6000K)

62

-

-

... More
S.E.T.C of 10W LED Bulk Head light fixture mounting in Lift Shaft and necessary driver, interconnecting wires & fixing hardwares etc , Maximum Power consumption not more than 11W. (6000K)

15

-

-

... More
S.E.TC of 32A,415V, TPN Industrial type socket outlet with 4 Pole and earth, metal enclosed plug top along with 32A 4P MCB in sheet steel enclosure

2

-

-

... More
Supply, erection, testing & commissioning of following sizes of perferated type cable trays including Tees, Bends etc. with accessories as required by the site condition.

-

-

-

... More
300mm(W) X 75mm(H)

45

-

-

... More
150mm (W) X 50mm(H)

185

-

-

... More
100mm (W) X 50mm(H)

15

-

-

... More
Supply, erection, testing and commissioning of DOL Starter Panel suitable for operation of 2.5 KW Exhaust fan motor each comprising of 1 - 32A 4P MCB, 1 - Main contactor of suitable rating for operation of 2.5 KW motor. 1 - Local /remote sector switch. 1 - 2 NO + 2 N/C Auxilary conact for external linking duly wired upto terminal block. 1 - Green colour push button actuator with 1 NO + 1 N/C contact eliment for switching ON of motor locally. 1 - Red colour push button actuator with 1 NO + 1 N/C contact eliment for switching OFF of motor locally. 1 - Set of RED & GREEN ON-OFF indicating lamp.1 - Set of Potential circuit fuses/MCB for control & indication.

1

-

-

... More
Supply and laying of following sizes of 1.1KV grade XLPE insulated armoured FRLS grade cable with aluminium conductor multistrand cable with ISI markings of approved make and quality from Existing AHU room Panel to various switch boards / Distribution boards . The cable shall be laid in the cable trays, racks (excluding supply & erection of cable trays / racks) Wherever cable are required to be laid on wall, base bracket fitted onto wall / ceiling and necessary clamps/ harwares etc. all complete and the rate for such clamps, hardwares shall be included in the scope. Before laying the cable approval for the routing and the manner of laying shall be obtained Engineering incharge.

500

-

-

... More
Supply and providing cable end termination for following sizes of 1100V grade XLPE insulated armoured FRLS grade aluminium conductor multi-strand cable with necessary gland and jointing materials etc. all as per requirement.

-

-

-

... More
4C 10 Sqmm..Al.Ar.cable

8

-

-

... More
4C 16 Sqmm..Al.Ar.cable

36

-

-

... More
4C 6 Sqmm..Al.Ar.cable

24

-

-

... More
Supply and providing cable end termination of 4 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete

16

-

-

... More
Supply, erection, testing and commissioning of SMC Box with 6A SP MCB & 4Way connector with all fixing accessories as required.

15

-

-

... More
Supply, erection, testing and commissioning of the following rating of inverter Systems for emergency lightings. Supply of Micro Processor Controlled 1.5 KVA inverter of input supply of 230 Volts ± 15%, 1 Phase, 50 Hz ± 5% and an out put of 230 Volts ±1%, 1 Phase 50 ± 0.01 Hz consisting of Rectifier, Inverter, Battery Circuit Breaker, Static and Manual Bypass Switches and all others accessories required . Supply of Sealed Maintenance Free Batteries to support 1.5 KVA for 30 minutes complete with intercell connectors, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries Installation, Testing and Commissioning of complete 1 no. 1.5 KVA inverter system with the battery bank including inter connection of system and battery banks with adequate size of copper cable, lugs etc. complete as required.

1

-

-

... More
Supply, erection, testing and commissioing of LED STRIP light fittings complete with all accessories with Drives Bajaj Cat. No.- NXT 25W PROFESSIONAL LED STRIP IP65 WH

300

-

-

... More
S.E.T.C of Gate Light 45W LED IP65 light fixture to be fitted in Gate as per site requirement with necessary frame, driver, interconnecting & fixing hardwares etc. , Maximum Power wires consumption not more than 40W. Bajaj Cat. No. - BGCL 40W LED WH

2

-

-

... More
Supply, fixing, testing and commissioning of 12 W LED Focus Light, Luminaire made of die cast aluminium alloy with non corrosive SS fasteners & bracket for permanent installations on a wall, under a ceiling or on a pillar. Ideal for the illumination of plants, including foundation bolts manufactured from special steel along with nuts, washers,anchor plates and templates & including foundation as per manufactures standards. K-Lite Cat. No. ID: 4267 -12 W LED

6

-

-

... More
Supply, fixing, testing and commissioning of chandelier Light, & bracket for permanent installations on a ceiling for the illumination etc as requitrd .

5

-

-

... More
Supplying, fixing testing and commissioning of Riflection 6W Warm White Round LED COB Spot Light

20

-

-

... More
S.E.T.C of Floor mounting 15W LED IP65Buried light fixture to be fitted in Floor as per site requirement with necessary frame, driver, interconnecting & fixing hardwares etc. , Maximum Power wires consumption not more than 15W. Bajaj Cat. No. - BA WO 15W (WH/WW)

12

-

-

... More
S.E.T.C of Surface mounting 1200mm at each 20W light fixture to be fitted as per site requirement with necessary frame, driver, interconnecting & fixing hardwares etc. , (Cool white)

4

-

-

... More
TELEPHONE, CCTV & SPEAKER SYSTEM

-

-

-

... More
Supply, Fixing and Termination of RJ11 Single Point ( Point to Point ) Crimping, Testing and arrangement charges.

1

-

-

... More
Supply & Installation of CAT 6 PVC Module Box

1

-

-

... More
Supply & Installation of Face Plate Single Socket RJ-45

1

-

-

... More
Supply & Fixing of Two meters patch cord in patch panel to Network Switch - 2 Metres Length

28

-

-

... More
Supply & Fixing of One meter patch cord in patch panel to Network Switch - 1 Metre Length

28

-

-

... More
Supply and Laying of 2 Pair Unarmoured 0.5mm Telephone cable

100

-

-

... More
Supply and Laying of Unarmoured LAN & CCTV Cable - CAT -6

1192.4

-

-

... More
Supply & Installation of Indoor 4 Mega Pixel Fixed Dome IP Camera

16

-

-

... More
Supply & Installation of Outdoor 4 Mega Pixel Fixed Bullet IP Camera

13

-

-

... More
Supply,Erection,Testing & Commisioning of 32 channel NVR to support for 18 cameras & in built storage slots with 4nos of 8 TB HDD Capacity.The NVR shall be capable of remote monitoring facility, web application viewing, and central monitoring system with CMS software and mobile application (APP) viewing. The same shall be with Hot standby redundancy on RAID 5. The vendor to submitted hard disk calculation sheet for 30 days backup

2

-

-

... More
Supply, Erection, Testing & Commisioning of PoE Switches For CCTV IP Camera - 24 PORT

1

-

-

... More
Supply, Erection, Testing & Commisioning of PoE Switches For CCTV IP Camera - 8 PORT

1

-

-

... More
Supply & Installation of Rack with Accessories - 6U Rack (DATA & CCTV)

1

-

-

... More
Supply and Laying of 25mm dia PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

629.2

-

-

... More
Supply, Installation, Testing and Commissioning of 55" smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remote p) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung).

1

-

-

... More
PA SYSTEM

-

-

-

... More
Supply & Installation of 15W high efficiency PA Wall speaker

11

-

-

... More
Supply & Installation of 15W high efficiency Ceiling speaker

16

-

-

... More
Supply & Installation of PA Booster Amplifier-480W

1

-

-

... More
Supply, fixing & Testing of 6/8 digital Zone selector with announcement microphone.

1

-

-

... More
Supply, run, testing and commissioning of 2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.

600

-

-

... More
Supply & Installation of custom built M.S Powder coated wall mounting Audio rack with Lock & key for housing of Amplifier & player/Recorder conforms to EIA-310,IEC-60297 and able to withstand the load of 40kg with welded construction made up of CRCA steel with suitable height, width and depth.

1

-

-

... More
Supply & Installation of System with CPU, Key board, mouse & Monitor HD (32") computer specifications: "Processor: Intel i5, equivalent AMD or greater processor, Memory: 16 GB RAM, Storage: 1 TB solid state (SSD) hard drive or larger, Web camera and mic Network: 10/100/1000 BASE-T Ethernet Wireless: 802.11 g/n dual band (2.4/5.0 GHz) Operating System: Windows 11 Professional "

1

-

-

-

-

-

... More
Supplying, erecting, testing and commissioning of machine room less passenger Elevator having 20 passengers capacity, rated speed 1.0 mtr. / sec., for GF,1st,2nd,3rd & Terrace floor, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with / with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman's switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door

1

-

-

... More
Supplying, erecting, testing and commissioning of having goods lift, rated speed 1.0 mtr. / sec., for GF & 1st, 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with / with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman's switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door

1

-

-

... More
PLUMBING

-

-

-

... More
Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting.

11

-

-

... More
Supplying and fixing in position Indian water closet of size 580 x 440mm, glazed earthern ware of approved quality and colour with 'P' trap or 'S' trap confirming to IS:2556-part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One of Lime, Two of Sand, Five of Brick jelly) 100mm thick and by dismantling brick masonry, reinforced finishing to the required slope and including giving necessary connection to PVC soil pipes cement concrete roof / floor slab and making good the disturbed portion to origional condition without leakage etc., complete complying with standard specification and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works)

4

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make 15mm CP health faucet ( For EWC ) with including Two way Bib cock (Angle cock with Pillar cock) CP flexible tube 1.0m long, CP crutch, nozzle etc.,complete.

11

-

-

... More
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).

12

-

-

... More
Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)

6

-

-

... More
Supply,Shifting (store) to the place of installation,fixing of approved make and model for CP brass two way coat hooks of superior quality with CP screws.

15

-

-

... More
Supplying and fixing position PVC Nahani Trap / Floor Trap of the following sizes with best PVC gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)

24

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make and model one no Concealed stop cock with wall flange,The works shall include cutting and making good the walls/floors.

-

-

-

7

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make and model one no SS Heavy Duty Long Body Tap 15mm,The works shall include cutting and making good the walls/floors.

10

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make and model one no CP Wall Mixture Tap 3 in 1 system with Hand ShowersThe works shall include cutting and making good the walls/floors.

7

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make and model one no CP Shower Arm with Overhead Shower Rose,The works shall include cutting and making good the walls/floors.

7

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make and model one no CBrass Chromium Plated Pillar Tap(Heavy Type) - 15 / 12mm dia,The works shall include cutting and making good the walls/floors.

14

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning of approved make and model one no Automatic Electrical Water Heater with copper container,with Glass Wool / Puf Insulation with MS powder coatedshell suitable for 25 Litres capacity 230V / 1000W (LowerEnd) The works shall include cutting and making good the walls/floors.

7

-

-

... More
Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives work shall include cutting, de burring, jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hours etc. making holes, including chasing in all kind of walls with groove cutting machine to required width and depth, making bores in masonry walls, making good the walls and bores in CC or CM 1:3 as applicable clearing the debris, grouting of concealed pipes with cement mortar ratio 1:6. MS hooks for fixing pipes and making good the walls and floors. The CPVC pipes shall be got approved by Executive Engineer before use on works

-

-

-

... More
INTERNAL WATER SUPPLY (Concealed) - Domestic, Flushing & Hot water

-

-

-

... More
20 mm dia

50.82

-

-

... More
25 mm dia

48.51

-

-

... More
32 mm dia

92.95

-

-

... More
Providing & fixing testing and commissioning of UPVC (Unplastisized Poly Vinyl Chloride) water supply pipes with pipe as per CTS SCH - 40 at a working pressure of 320 PSI at 23 deg C & 80 PSI at 82 deg C, using solvent welded UPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings connection between UPVC & metal pipe/GI) ie. Brass Adaptors (both Male & Female threaded) conforming to ASTM with only UPVC solvent cement conforming to ASTM F-493 with fabricated & subsequently hot dip galvanized clamps / structural steel supports as required / directed at site including cutting chasing and fixing the same with cement concrete / cement mortar as required, including painting the exposed pipes with one coat of desired shade of enamel paint. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to the satisfaction of PMC /Consultant / manufacturer of pipes & fittings.

-

-

-

... More
EXTERNAL WATER SUPPLY (Shaft,Terrace & False Cieling) - Domestic & Flushing Water

-

-

-

... More
32 mm dia

207.9

-

-

... More
40 mm dia

196.9

-

-

... More
50 mm dia

151.8

-

-

... More
Supplying & fixing in position first quality & approved variety of various dia Gun metal Gate valves ( Heavy type ) with I.S.I. Mark of the following size including cost of Shellac, thread etc.,including labour for cutting & threading of Pipes etc., complete complying with standard specifications for both internal & external water supply arrangements.

-

-

-

... More
32 mm dia

6

-

-

... More
40 mm dia

3

-

-

... More
50 mm dia

5

-

-

... More
Supply, erection testing & commissioning of pot strainer / Y Strainer. Rate shall include for rubber insertion, bolts, nuts GI flanges.

-

-

-

... More
50mm dia

2

-

-

... More
40mm dia

2

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid above ground level

-

-

-

... More
INTERNAL (Embedded in floor) :

-

-

-

... More
75mm dia

56.24

-

-

... More
110mm dia

36.33

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level Notes: The vertical down take pipes running in shaft shall be rubber ring joint

-

-

-

... More
The horizontal pipes running suspended in the ceiling leel shall be to self fit type with solvent cement joint.

-

-

-

... More
EXTERNAL (Shaft / Ceiling Suspended):

-

-

-

... More
75mm dia

169.4

-

-

... More
110mm dia

168.3

-

-

... More
Providing, fixing, jointing and testing in position the following uPVC pipes for soil and sullage waste confirming to IS:4985 of 6 Kg / Sq.cm for drainage system cut to required length. Pipe to be laid below ground level upto required depth (Slope Level) in all kind of soil (hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round / haunches as per specification.(For sewer and Sullage line) Rate Should be excluding excavation for earthwork and backfilling.

-

-

-

... More
EXTERNAL (Buried):

-

-

-

... More
75 mm dia

7.7

-

-

... More
110 mm dia

7.7

-

-

... More
160 mm dia

60.5

-

-

... More
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.

-

-

-

... More
40 mm dia (Minimum 6kg / sq.cm)

47.85

-

-

... More
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three crushed stone sandand Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.

6

-

-

... More
Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of second class Table Mould Bricks of size 9" x 43/8" x 23/4" with Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. Notes: Rate Quoted shall be inclusive of cost of cement, sand and other consumables etc. Chamber Internal diameter conforming to IS 12592, total weight of cover and frame to be not less than 182 Kgs fixed in cement concrete.

-

-

-

... More
Inside size of 600 x 600mm & depth up to 900mm

13

-

-

... More
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.

-

-

-

... More
PVC rain water buried 160mm dia

123.2

-

-

... More
Providing and fixing testing and commissioning 600mm long puddle flange conforming to IS: 2062 of 6mm thick welded GI plate, flanges of sutible size Properly fixed in walls of water tank as per specifications with both end threaded with one end plug for sizes up to 50mm and and for sizes 50mm and above with one end flange and other end threaded of following diameters. Note: Puddle Square Plate size as follows for 25mm dia Puddle Flange the plate shall be 150mm (L) x 150mm (W),for 32,40,50,65,80mm dia - 200mm (L) x 200mm (W),100mm dia - 250mm (L) x 250mm (W),150mm dia - 300mm (L) x 300mm (W),200mm dia-350mm (L) x 350mm (W)

-

-

-

... More
25 mm dia

1

-

-

... More
32 mm dia

1

-

-

... More
65 mm dia

6

-

-

... More
80 mm dia

2

-

-

... More
150 mm dia

5

-

-

... More
Providing and fixing testing and commissioning of PVC rungs shall be set staggered in two Horizondal rungs which may be not more than 380 mm (from center to center) apart horizontally as well as vertically not more than 300 mm (from center to center) and shall project a minimum of 150 mm beyond the finished surface.The top rung shall be 450 mm below the manhole cover and the lowest not more than 300 mm above the benching/bottam of sump (or) over head tank.

165

-

-

... More
Supplying and fixing in position FRP manhole covers with frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications

33

-

-

... More
DOMESTIC WATER PUMP - ( U.G SUMP TO OHT) Supplying and fixing 3 HP / 3 Phase, 9 Stage sub mergible pump of approved make and quality with ISI mark with necessary accssories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following additional accssories 1 No of 3 Phase Star Delta Starter of 63 AMPS of approved quality and make with ISI mark 1 No of 3 Phase 63 AMPS Main Switch of approved quality and make with ISI mark. 1 No of priventor of approved quality and make with ISI mark 1 No of pannel board of required size with indicator fuse unit voltmeter with necessary provision toaccomodate the starter and mini starter etc. 1 No of capacitor with board as per standards of TNEB

2

-

-

... More
TREATED WATER PUMP - ( U.G SUMP TO OHT) Supplying and fixing 3 HP / 3 Phase, 9 Stage sub mergible pump of approved make and quality with ISI mark with necessary accssories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following additional accssories 1 No of 3 Phase Star Delta Starter of 63 AMPS of approved quality and make with ISI mark1 No of 3 Phase 63 AMPS Main Switch of approved quality and make with ISI mark. 1 No of priventor of approved quality and make with ISI mark 1 No of pannel board of required size with indicator fuse unit voltmeter with necessary provision toaccomodate the starter and mini starter etc. 1 No of capacitor with board as per standards of TNEB

2

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning and handing over of approved make and model Booster Pump (for domestic water) of flow 500 liters per hour with head of 20m and pressure vessal of 75 Liters,float switch of required length and pressure switch with necessary specials fixing to wall with clamps,screws,connecting pipes,etc including suitable control panel and bypass line (Incase of power failure / Pump failure) with making holes in the wall or drilling holes in roof and making good the wall or roof after fixing with necessary items etc.,complete

1

-

-

... More
Supply,Shifting (store) to the place of installation,fixing,testing and commissioning and handing over of approved make and model Booster Pump (for flushing water) of flow 300 liters per hour with head of 20m and pressure vessal of 75 Liters,float switch of required length and pressure switch with necessary specials fixing to wall with clamps,screws,connecting pipes,etc including suitable control panel and bypass line (Incase of power failure / Pump failure) with making holes in the wall or drilling holes in roof and making good the wall or roof after fixing with necessary items etc.,complete

1

-

-

... More
Supplying and fixing Aluminium towel rail 600mm long and 20mm diameter with brackets of same materials including cost of teak wood plug and CP screws etc., complete complying with standard specification and as directed by the Departmental officers.

7

-

-

... More
STP - 15KLD (MBBR SYSTEM)

-

-

-

... More
PRIMARY TREATMENT - 15.00 CU.M / DAY M.S BAR SCREEN Supplying, installing, testing and commissioning of bar screen of 1 Nos. so as to remove the large sized particles present in the sewage water associated with set of guide angles in MS flat of 6.0 mm thick and 25 mm wide kept inclined at 45 degree to the horizontal at 15 mm c/c with one no. handrack in MS. Bar rack fabricated from MS bars shall be provided to cover the width of the screen chamber Size : 1000 mm x 600 mm

1

-

-

... More
M.S. BAR SCREEN RAW SEWAGE PUMPS (SELF PRIMING TYPE) Supplying, installing, testing and commissioning of 2 Nos. (one working + one standby) Monobloc type raw sewage water pumps to pump sewage from equilisation sump to aeration tank at.1 cu.m / hr flow rate. The pump shall be of "Self Primming Type" The Pump shall be suitable for Solid handling capacity of 7.0 mm. The pump shall be suitable for the following requirements: Flow rate - 1 cu.m / hr, Head - 12 - 15 mtr, The rate quoted shall be inclusive of Earthing for pumps to be included. Dry Run Protection, 2 nos. of C.I. Butterfly valve with C.I. (S.G. Iron) Dish with EPDM Seat with PN 16 Rating Handle leaver with IS 13095 Mark on Suction Side 2 nos. of C.I. Butterfly valve with C.I. (S.G. Iron) Dish with EPDM Seat with PN 16 Rating Handle leaver with IS 13095 Mark on Delivery Side UPVC manifold of suitable dia on delivery side finished neatly with flanged end on either sides and collar provision for connectivity of above mentioned valves.

1

-

-

... More
RAW SEWAGE PUMPS COARSE BUBBLE DIFFUSERS Supplying, installing, testing and commissioning of Coarse bubble duffuser with 45 mm Dia X 450 mm Long of PVC pipe grid with necessary orifices PVC pipe of 6.0 kg / sq.cm pressure rating with removable deflector to Provide clog-free oxygen for Equalisation tank and Sludge Holding Tank.

1

-

-

... More
COARSE BUBBLE DIFFUSERS FINE PORE DIFFUSERS Supplying, installing, testing and commissioning of Fine bubble diffuser with 45 mm Dia x 500 mm Long membrane Shall consists of set of EPDM membranes, SS 304 clips PVC support pipe(10 ksc pressure rating),PVC fitting(like elbows, tees, collars etc), nylon rope braided hose with all accessories to make it retrievable.

1

-

-

... More
FINE PORE DIFFUSERS MBBR MEDIA "Supplying, installing, testing and commissioning of MBBR Media Consisting of the following: Type: Cyclindrical type Surface area: As per System requirement MOC: PVC / PP

1

-

-

... More
MBBR MEDIA AIR BLOWER "Supplying, installing, testing and commissioning of 2 Nos. (one Working + one Standby) Twin Lobe design type air blower complete with motors, pulleys, One piece rigid CI casing and side plates, silencer,base plate, Anti-friction bearings, Rotary oil sealings having horizontal configuration. The blower shall be suitable for the following: Flow rate of each blower - 24.00 Cu.m / hr, Flow Pressure - 0.50 kg / sq. cm Head - 5 mtr, Earthing for air blowers and motors complete. The rate quoted shall be inclusive of 1 no. pressure guage 4" dial with valve tee and fittings. Twin Lobe roots type Airblower of 24.00 cum/hr at 0.50 kg/sqcm capacity comprising of common base frame, suction filter, suction silencer, non return, V belt, guard, drive and driven pulleys, pressure guage, inter connection pipping, discharge silencer,including required motor of make Kirloskar, Motor for Airblower to be provided / included. 2 nos. spring Flap Type Non return valve / Slim seal flap type check valve with CI body and cast steel disc tested to PN - 10 kg / sq.cm pressure including a set of MS Flanges as per BS - 10 table 1 including bolts, nuts, GI washers and neoprene rubber gaskets complete etc., on the delivery side. MS manifold of suitable dia on delivery side finished neatly with flanged end on either sides and collar provision for connectivity of above mentioned valves.

1

-

-

... More
AIR BLOWER RETURN SLUDGE PUMPS (SELF PRIMING TYPE) Supplying, installing, testing and commissioning of 2 Nos. (One working + One stand-by) Return Sludge Disposal pumps to pump the sludge from Secondary settling tank back to aeration tank. The pump shall be Horizontal Centrifugal Non - Clog Pumps with wetted parts in CI construction. The pump shall be coupled to the adequate H.P. electrical motor and shall be mounted on a common base frame with mani fold. The pump shall be suitable for the following requirements: Flow rate - 1 Cu.m / hr, Head - 12 - 15 mtr, The rate quoted shall be inclusive of Earthing for pumps complete. 1 no. pressure gauge 4" dial with needle valve and tee fittings. 2 nos. of C.I. Butterfly valve with C.I. (S.G. Iron) Dish with EPDM Seat with PN 16 Rating Handle leaver with IS 13095 Mark on Suction Side 2 nos. of C.I. Butterfly valve with C.I. (S.G. Iron) Dish with EPDM Seat with PN 16 Rating Handle leaver with IS 13095 Mark on Delivery Side UPVC manifold of suitable dia on delivery side finished neatly with flanged end on either sides and collar provision for connectivity of above mentioned valves.

1

-

-

... More
Total - RETURN SLUDGE PUMPS CLARIFER MECHANISM Supply of Clarifier Mechanism to fit into Secondary Clarifier tank with centre shaft ,suitable motor, gear box, shaft, cone scraper/guide bush , raker arm with rubber squeezes, tie rod , Chain & Sprocket etc. Size of Clarifier : 1.50 x 1.50 x 2.50 Mtr (Total height) (Approx.) MOC of Clarifier : MS with Epoxy coated

1

-

-

... More
CLARIFIER MECHANISM SLUDGE DEWATERING SYSTEM Supplying, installing, testing and commissioning of Plate and Frame type Mechanical Sludge De-watering system consisting of 25 mm Cake thickness provided with hydraulic closing mechanism. One no. single moulded HDPE Cylindrical type Chemical solution tank of 100 litres capacity having detachable lids with moulded inserts for mounting of pumps and hand stirrer. Quanitity - 1 no, Model - As Per Manufacturer, Type - Manual hydraulic MOC – MS, Plate size - 200 x 200 MM, No. of Plates - 7 Plates, No. of chamber - 7 Chambers, Fliltration Area - 5 Sq.Mtr, Operating pressure - 3 Kg/Cm2

1

-

-

... More
SLUDGE DEWATERING SYSTEM SCREW PUMP Supplying, installing, testing and commissioning Consisting of 1 No.single screw double stage pumps flanged ends with CI body ally steel rotating parts etc., complete to pump sewage from Sludge holding tank to Filter press at 1.00 cum / Hr flow rate. The pump shall be coupled to the adequate H.P. electrical motor, mounted on a common base frame. The rate quoted shall be inclusive of: Earthing for pumps complete. Quantity - 1 No, Model - As Per Manufacturer Type - Helical screw pump, Flow rate - 1.00 m3/Hr, Head - 15 m, Rating - 1.0 HP, Power Supply - 3 Phase, Casing – CI, Impeller – CI, Seal - Mechanical seal, MOC – CI, Enclosure – CI, Class of Insulation - As Per Manufacturer

1

-

-

... More
FILTER FEED PUMP Supplying, installing, testing and commissioning of 2 Nos. (one Working + one Standby) Monobloc type Clarified water from Clarified Water sump to Filter Feed at 1 Cu.m / hr Flow rate. The pump shall be of "Horizontal Monobloc Type Pumps" The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'MS' with necessary bolts, nuts. The pump shall be suitable for the following requirements: Flow rate - 1 cu.m / hr, Head - 10-15 mtr, The rate quoted shall be inclusive of: Earthing for pumps to be included. 1 no. pressure gauge 4" dial with needle valve and tee fittings. 2 nos. of C.I. Butterfly valve with C.I. (S.G. Iron) Dish with EPDM Seat with PN 16 Rating Handle leaver with IS 13095 Mark on Suction Side 2 nos. of C.I. Butterfly valve with C.I. (S.G. Iron) Dish with EPDM Seat with PN 16 Rating Handle leaver with IS 13095 Mark on Delivery Side 2 nos. C.I. Wafer Check Valve / Ball Check Valve (Threaded) of PN 06 Rating on Delivery side UPVC manifold of suitable dia on delivery side finished neatly with flanged end on either sides and collar provision for connectivity of above mentioned valves.

1

-

-

... More
MS SAND PRESSURE FILTER (PSF) Supply, installation testing and commissioning of sand pressure filter for filtration of suspended impurities in treated sewage water. The filter shall be suitable for 1 Cu.m / hr flow rate and designed to remove suspended particals / impurity in treated sewage water. The SPF shall be designed for a specific velocity of 2 m3 / hr / sq.m area and the approx dia shall not be less than 900 mm dia The Sand Pressure Filter unit shall comply with the following technical requirements: Flow rate - 1 Cu.m / hr, Back wash duration - 15 minutes, Painting Internal - Two Coats of Anti - Corrosive Epoxy paint, Painting external - Two coats of Redoxide Paint and above that a layer of two Coats of Enamel paint to be done to give the finishing. Filtering Media - Sand / Pebbles pressure drop across unit. - 0.5 Kg/ sq.cm (max), Inlet turbidity - 1.00 as NTU Dia of sand pressure filter unit - 450 mm dia. Further, the sand pressure filter unit shall comprise of the following The sand pressure filter vessel shall be fabricated out of MS plate not less than 5 mm thick with dish ends out of 6 mm thick plate and painted internally with two coats of anticorrosive Epoxy paint and externally with two coats of enamel paint of approved colour. The Sand Pressure filter shall be fitted with top inlet distribution and bottom collecting system. Pressure gauge shall be provided at inlet and out let of Sand Pressure filter. Initial charge of underbed and multigrade filtering media as required. Complete set of valves, pressure gauge with needle valve and frontal piping at inlet, outlet backwash and drain out point etc., with MS 'B' class pipes.

1

-

-

... More
MS ACTIVATED CARBON FILTER (ACF) Supply, installation, testing and commissioning of activated carbon filter for filtration and removal of colour in treated sewage water. The filter shall be suitable for 1 Cu.m / hr flow rate and designed to operate for 16 hours. The ACF shall be designed for a specific velocity of 8 m3 / hr / sq.m area and the approx dia shall not be less than 900 mm dia, The activated carbon filter unit shall comply with the following techinical requirement. Flow rate - 1 Cu.m / hr, Back wash duration - 15 minutes, Painting Internal - Two Coats of Anti - Corrosive Epoxy paint, Painting external - Two Coats of Redoxide Paint and above that a layer of two Coats of Enamel paint to be done to give the finishing. Filtering Media - Activated carbon - IV 900, Pressure Drop across unit. - 0.5 kg / sq.cm (max), Dia of activated carbon filter unit - 450 mm dia. Further the activated carbon filter unit shall comprise the following: The activated carbon filter vessel shall be fabricated out of MS plate not less than 5 mm thick with dish ends out of 6 mm thick plate and painted internally with two coats of anticorrosive Epoxy paint and externally with two coats of enamel paint of approved colour. The Activated Carbon Filter shall be fitted with inlet distribution and bottom collecting system. Pressure gauge shall be provided at inlet and out let of Activated Carbon filter. Initial charge of underbed and multigrade filtering media as required. Complete set of valves, pressure gauge with needle valve and frontal piping at inlet, outlet backwash and drain out point etc., with MS 'B' class pipes (make: Tata / Jindal).

1

-

-

... More
ULTRAVIOLET STERILIZER Supply, installation, testing and commissioning of the ultraviolet sterilizer suitable for flow rate of 1 cu.m / hr. The unit shall be suitable for removing the bacteria in STP Treated water. The unit shall comply with the following technical specifications. Unit shall be suitable for a working pressure of 2.5 sq.cm, Mounting brackets to be provided. Suitable for 220V single phase power supply operation. Stainless steel type 304 electropolished purification chamber. High instensity UV lamps rated for min of 7500 hours continuous use

1

-

-

... More
CHLORINE DOSER Supply, installation, testing and commissioning of electronic Chlorine dosing unit with automatically operated dosing pump etc. The unit shall comprise of the following: One no. single moulded HDPE cylindrical type chemical solution tank of 50 litres capacity having detachable lids with moulded inserts for mounting of pumps and stirrer. One on. Electronic diaphragm type positive displacement pump of E DOSE / Focus make, for chemical dosing with plastic head. The electronic pump shall be operated on 220V single phase supply and shall be mounted directly on the tank top. Complete set of pipes, valves and fittings, foot valve magnetic float switch to trip the dosing pump at low level of chemical in the tank. The free chlorine content in the filtered water shall not be less than 0.5 PPM. The pump shall be suitable for the following requirements: Min. Actuating Pressure - 0.3 kg/sq cm, Max. Working Pressure - 0.5 kg/sq cm, Max. Temperature - 50 degree Centigrade, Dosing flow range - ( 0 - 3 LPH), Head - 5 - 10 mtr

1

-

-

... More
MCC PANEL WITH BMS PROVISION Supply, fabrication, erection testing and commissioning "Non Compartmentalised" Floor Standing Electrical Control Panel for RSTP, Air blowers,RSP, filter feed pumps. The Panel shall be sheet steel fabricated, finished with powder coating of approved color, and of floor mounted, free standing cubicle type with incoming MCC TP and N bus bars and outgoing with fuse switch units, starter relays, over load, etc. The panel shall have Voltmeter, Ammeter and indicating lamps on the incoming side only. The rate quoted shall be inclusive of the following Earthing for panels, Dry run protection arrangement for the following Raw Sewage Pump, Filter Feed Pump

1

-

-

... More
INTERCONNECTING PIPES & FITTINGS Supply of interconnecting pipes & fittings MOC of the piping shall be MS 'B' Class ("TATA" OR "JINDAL" Make) for air lines and UPVC for water lines(Astral / Supreme / Finlolex)

1

-

-

... More
ELECTRO MAGNETIC FLOWMETER(EMF) AT RSTP OUTLET Supply, installation, testing and commissioning of Electro magnetic Flowmeter at Raw sewage transfer pump Outlet for a flow rate of 4.20 cu.m / hr. The unit shall be Online mounted with necssary Flanges, Gasket & Bolts and nuts etc., Size : 40 NB, Type: Full bore, Flange: Mild steel, Electrode : SS 316, Liner : Rubber / PTFE, Coil Housing : Mild steel / SS 304, Output : RS 485, Make: Aster / Forbes marshall / E&H

1

-

-

... More
ELECTRO MAGNETIC FLOWMETER(EMF) AT ACF OUTLET Supply, installation, testing and commissioning of Electro magnetic Flowmeter at Raw sewage transfer pump Outlet for a flow rate of 1 cu.m / hr. The unit shall be Online mounted with necssary Flanges, Gasket & Bolts and nuts etc., Size : 40 NB Type: Full bore Flange: Mild steel Electrode : SS 316 Liner : Rubber / PTFE Coil Housing : Mild steel / SS 304 Output : RS 485 Make: Aster / Forbes marshall / E&H

1

-

-

... More
FILTER FEED PUMP FOR ULTRAFILTRATION Supplying, installing, testing and Commissioning of 2 Nos. Monobloc Type (One Working and One Standby) feed pumps for pumping the water from final treated water sump to Ultra filtration for further treatemen/polishing/removal of micro organisms and bacteria. The pump shall be coupled to the adequate H.P. electrical motor and shall be mounted on a common base frame with mani fold. The pump shall be suitable for the following requirements: Flow rate - 1.00 Cu.m / hr, Head - 15 mtr, The rate quoted shall be inclusive of: Earthing for pumps to be provided 1 no. Pressure gauge 4" dial with valve tee and fittings. 2 nos. of UPVC ball valve SCH 40/80 Rating suitable on Suction side. 2 nos. of UPVC ball valve SCH 40/80 Rating suitable on Delivery side. 2 nos. C.I. Wafer Check Valve / Ball Check Valve (Threaded) of PN 06 Rating on Delivery side Alarm indication with signal in the event of pump failure etc. UPVC manifold of suitable dia on delivery side and suction side with flanged end on either sides and collar provision for connectivity of above mentioned valves.

1

-

-

... More
SS 304 / UPVC BAG FILTER HOUSING WITH 100 MICRONS BAG FILTER Supplying, installing, testing and commissioning of 2 Nos.(both working) UF Bag Filter one afetr the UF feed pump before entering the UF system to protect the UF Membranes from the coarse solids entering the UF process and other at the UF Backwash pump outlet to prevent any foriegn particles entering into the UF Membranes UF FEED Flow rate : 1.00 Cu.m / hr, Size : 4 " Dia x 10 " Long Bag Filter Housing, Micron : 100 Micron Bag, MOC : PP / UPVC, Type : Screwed end on top for removal of UF Bag Filter

1

-

-

... More
UF BACKWASH Flow rate : 21.00 Cu.m / hr, Size : 7 " Dia x 32 " Long Bag Filter Housing Micron : 100 micron Bag, MOC : SS 304 / UPVC, Type : Flanged end on both sides & Clamp type provision on top for removal of UF Bag Filter

1

-

-

... More
ULTRA FILTRATION MEMBRANES (CROSS FLOW MODE) Supplying, installation, testing and commissioning of Ultra filtration system to separate the treated effluent and concentrated MLSS to make it suitable for reuse in toilet flushing system the U.F. system shall consists of the following: U.F : 7 Cu.m / day, Membrane Flux : 15 LMH, Total Membrane Surface area - 75 sqm(Max), Type: In to Out, MOC: Modified polyether sulphone

1

-

-

... More
Supply, installation, testing and commissioning of chemical cleaning unit with automatically operated pump etc., The unit shall comprise of the following: One no. single moulded FRP cylindrical type Hydochloric Acid solution tank of 30 litres capacity having detachable lids with moulded inserts for mounting of pumps and stirrer. One on. Electronic diaphragm type positive displacement pump of Anala / Asia LMI make, for hydrochloric acid with plastic head. The electronic pump shall be operated on 220V single phase supply and shall be mounted directly on the tank top. Complete set of pipes, valves and fittings, foot valve magnetic float switch to trip the dosing pump at low level of polymer in the tank. Concrete bed/pedestals of suitable size and thickness in cement concrete 1:2:4 for mounting the doser base with anchor fastener, bolts and nuts and neatly finished smooth with floating coat of cement mortar. The pump shall be suitable for the following requirements: Min. Actuating Pressure - 0.3 kg/sq cm, Max. Working Pressure - 0.5 kg/sq cm, Max. Temperature - 50 degree Centigrade, Dosing flow range - 0 - 30 LPH, Head - 3 - 5 mtr, Chemical: Hydrochloric acid (HCL)

1

-

-

... More
UF CLEANING TANK Supply, installation, testing and Commissiong of UF cleaning tank to mixing chemicals for futher use. Tank Capacity : 100 Ltrs MOC of Tank : FRP

1

-

-

... More
CAUSTIC DOSING SYSTEM Supply, installation, testing and Commissioning of on line automatic electronic hypo dosing unit with automatically operated dosing pump etc., The unit shall comprise of the following: One no. single moulded FRP cylindrical type Hypodosing solution tank of 30 litres capacity having detachable lids with moulded inserts for mounting of pumps and stirrer. One on. Electronic diaphragm type positive displacement pump of Anala / Asia LMI make, for hypo dosing with plastic head. The electronic pump shall be operated on 220V single phase supply and shall be mounted directly on the tank top. Complete set of pipes, valves and fittings, foot valve magnetic float switch to trip the dosing pump at low level of Hypodosing in the tank. Concrete bed/pedestals of suitable size and thickness in cement concrete 1:2:4 for mounting the doser base with anchor fastener, bolts and nuts and neatly finished smooth with floating coat of cement mortar. The pump shall be suitable for the following requirements: Min. Actuating Pressure - 0.3 kg/sq cm, Max. Working Pressure - 0.5 kg/sq cm, Max. Temperature - 50 degree Centigrade, Dosing flow range - 0 - 10 LPHm, Head - 3 - 5 mtr, Chemical: Caustic

1

-

-

... More
ULTRA FILTRATION BACK WASH PUMPS Supplying, installing, testing and commissioning of 2 Nos. Mono bloc type (One Working and one Standby) pumps for pumping the water from Ultrafiltration Treated water tank to UF Modules for Backwash Process. The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'MS' with necessary bolts, nuts,saddle and mesh. The pump shall be suitable for the following requirements: Flow rate - 2.00 Cu.m / hr, Head - 10 mtr, The rate quoted shall be inclusive of: Earthing for pumps complete. 1 no. pressure gauge 4" dial with valve tee and fittings. 2 nos. of UPVC ball valve SCH 40/80 Rating suitable on Suction side. 2 nos. of UPVC ball valve SCH 40/80 Rating suitable on Delivery side, 2 nos. C.I. Wafer Check Valve / Ball Check Valve (Threaded) of PN 06 Rating on Delivery side, UPVC manifold of suitable dia on delivery side with flanged end on either sides and collar provision for connectivity of above mentioned valves.

1

-

-

... More
CHEMICAL CLEANING PUMP Supplying, installing, testing and commissioning of 1 No. Monobloc type (One Working) feed pumps for pumping the water from Cleaning tank to Ultra filtration. The pump shall be suitable for the following requirements: Flow rate : 2.00 Cu.m / hr, Head : 10 mtr, MOC of pump : SS 304, The rate quoted shall be inclusive of Dry run protection, 1 no. pressure gauge 4" dial with valve tee and fittings, 1 no. of UPVC valve on Suction side, 1 no. of UPVC valve on Delivery side.

1

-

-

... More
ULTRA FILTRATION SKID Supplying, installing, testing and commissioning MS Fabricated Skid Coated with two coats of Epoxy Paint / Powder Coated with required supports and accessories of Ultra filtration Unit. The MS Fabricated skid should enclose the following: Ultra filtration Membranes of Total Membrane surface area mentioned above Pneumatic Actuated Valves of reputed make for plant auto operation(Cross flow mode) One number of Air compressor for Pneumatic actuated Valves. Hydraulic Hose to be connected between Air compressor and SS 304 Header SS 304 Header for Distribution of air to Pneumatic actuated Valves. One touch fitting with Flexible hose to be provided for supply of air to Pneumatic actuated Valves, UPVC Header line for UF Feed , UF Backwash & UF Product to be provided, One number of Glycerin filled Pr.Gauge at UF Feed Header, UF Backwash header & UF Product header, One number of Flowmeter / Rotometer at UF Feed, UF Backwash & UF product line

1

-

-

... More
MCC PANEL Supply, fabrication, erection testing and Commissioning of Combined / Common Motor Control Center Panel (MCCP) . The Panel shall be of "Non Comparmentalised" for UF Feed, UF Backwash & UF Chemical Cleaning pumps. The MCC shall be sheet steel fabricated, finished with powder coating of approved color, and sikd mounted, free standing cubicle type with incoming MCC TP and N bus bars and outgoing with fuse switch units, starter relays, over load, UV earth fault protection with time delay sequence operator etc. The panel shall have Voltmeter, Ammeter and indicating lamps on the incoming side only indicating lamps for the pumps on outgoing side to indicate the operation mode. The panel shall be complete in all respectsand prior to the supply, fabrication drawing shall be submitted for consultants approval. The rate quoted shall be inclusive of the following: Earthing for panels . Dry run protection arrangement for the following : Filter Feed Pump for Ultra filtration, Backwash Pump for Ultra filtration, Chemical cleaning pumps for Ultra filtration, HCL / Caustic dosing to be connected to UF Back wash line and operated thro PLC, Audio / visual alarm indication in the event of malfuntioning of UF, ALL UF PUMPS TO BE OPERATED THRO PLC SYSTEM ONLY

1

-

-

... More
INTERCONNECTING PIPES & FITTINGS Supply of interconnecting Pipes & Fittings MOC of the piping shall be UPVC for all water lines(Supreme / Finlolex / Astral / Ashirwad)

1

-

-

... More
FIRE FIGHTING

-

-

-

... More
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings complete in all respects as required. a. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 2850 LPM against a total head of 70 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring, etc., of noncorrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. c. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dynamo, solenoid switches etc. d. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre filter, after filter etc. e. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition. f. Dash board consisting of the instruments like Temperature Gauge, Galvano Type DC Ammeter, Lubricant Oil Pressure Gauge, Ignition Switch, Emergency Stop and all other protection equipments as per specification, stop soleneid for auto stop in the event of fault with audio indications, painted with Post Office Red Colour etc., as required. g. 12 V / 24 V, storage battery, maintenance free tape, 180AH rating. MS fabricated common base plate, coupling guard, foundation bolts, etc., as required. h. Positioning the Diesel Engine Driven Fire Pump over cement concrete foundation using suitable size anti vibration mounting arrangements.All works including conveying, fixing and incidental charges, etc., completed as per standard specification and as directed by the Departmental Officers. (Make: KIRLOSKAR / EQUIVALENT) (Based on SOR M-835)

1

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump rated for 2850 LPM at 70 metres head with Electrical Motor of 60HP of 415 volt, 3 phase connection complete with base plate and accessories. (Make Kirloskar or Equivalent). The rate inclusive of neessary vibration, bed mounting, etc., as per standard specifications and as directed by the Departmental Officers

1

-

-

... More
Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers.Make: KIRLOSKAR / EQUIVALENT.

1

-

-

... More
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’,elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.

-

-

-

... More
150 mm NB pipes.

92.4

-

-

... More
100 mm NB pipes.

26.4

-

-

... More
80 mm NB pipes.

24.53

-

-

... More
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anti corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.

-

-

-

... More
150 mm NB pipes.

120

-

-

... More
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.

4

-

-

... More
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT

4

-

-

... More
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.

4

-

-

... More
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.

8

-

-

... More
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.

4

-

-

... More
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc.as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
150 mm dia.

4

-

-

... More
Supply, erection, testing and commissioning of cast iron body and gun metal or stainless steel Internal Non-Return Valve of size of 80mm dia to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
80 mm dia.

1

-

-

... More
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers. Make: DONFOSS / INDFOSS / ISI MAKE / EQUIVALENT.

1

-

-

... More
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers

1

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIARTAR / OMEX / EQUIVALENT.

1

-

-

... More
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.

1

-

-

... More
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT

8

-

-

... More
Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers.

8

-

-

... More
Supplying, fixing, testing and commissioning Butterfly Valve (manual) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.

-

-

-

... More
150 mm dia

9

-

-

... More
80 mm dia

6

-

-

... More
Providing and fixing testing and commissioning of gun metal ball valves confirming IS 9890 with stainless steel ball, lever operated at Pressure rating PN 25

-

-

-

... More
20 mm dia

4

-

-

... More
25 mm dia

2

-

-

... More
Supply, erection testing & commissioning of CI Y Strainer. Rate shall include for rubber insertion, bolts, nuts GI flanges at Pressure rating PN 16

-

-

-

... More
150mm dia

3

-

-

... More
Providing and fixing of GI Threaded rods with Suitable Size Adjustable swivel hanger(s) for Sprinkler Pipes with anchor fasteners and necessary washers and nuts etc.,

55

-

-

... More
Note: Hanger rod dia (mm) must be 8mm and maximum Space Between Supports Shall be 2m for Ø25,Ø32,Ø40 Pipe(s) and 2.5m Spacing for Ø50 Pipes(s).Hanger rod dia (mm) must be 10mm and maximum Space Between Supports Shall be 2.5m for Ø65 Pipe(s) and 3m Spacing for Ø80, Ø100 Pipes(s). Hanger rod dia (mm) must be 12mm and maximum Space Between Supports Shall be 4m for Ø150 Pipe(s).

-

-

-

... More
Providing and fixing of MS brackets (ISMC75,250mm Long (approx.) fabricated out of required size with 6mm / 8mm GI `U' clamps with GI washers and nuts etc., for supporting MS pipes running in Shaft The work shall also include making hole grouting the same in RCC slabs / masonry walls with cement concrete and making good the same. for pipes supports including painting with one coat of primer and 2 coats of approved enamal colour paint.

55

-

-

... More
Supply and Laying of 32mm dia PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

52.8

-

-

... More
Supplying, installation, testing and commissioning of Fire Fighting Electrical Control Panel of cubical construction, floor mounted type fabricated using CRCA sheet, compartmentalised with hinged lockable door dust and vermin proof, cable alley, inter connection having switch gears and accessories mounting and internal wiring, earth terminals, numberings, necessary metering protections and indications complete in all respect suitable for operation on 415volt, 3 phase, 50 Hz AC supply with enclosure protection class IP 54 and mounted with the followings. A. Common Panel in Fire Pump House (i). Incomer a. 1 No. 600A TP & N SDFU with HRC fuses b. 1 set of 600A, 4 bar aluminium bus bar, 415 V, 50 HZ AC supply c. 1 No. (0-500A) digital ammeter with selector switch & CTs d. 1 No. (0-500V) digital voltmeter with selector switch and control fuses e. 3 Nos. phase indication lamp LED type with toggle switches with control fuses (ii). Outgoing a. Main Fire Pump 400 A TPN SDFU with HRC fuses with sutable HP fully automatic starter / delta starter with over load protection, digital ammeter with built-in selector switch and suitable CTs, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual / OFF operation - 1 No. b. Jockey Pump 125 A TPN SDFU with HRC fuses with suitable HP fully automatic starter / delta starter with over load protection, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual operation - 1 No. c. Diesel Engine Control comprising of: 1. Auto / manual selector switch and 3 attempt starting device, timers and relays as required, push buttons, start /stop in manual mode. 2. Indication lamp for high / low lubricant oil pressure, high water temperature and engine ON indication. 3. Battery charger suitable for 12V /24V DC with boost and tickle selector switch, 0-15V / 0-30V DC volt meter, 0-20A DC ammeter. 4. All standard relays and accessories for automatic operation of diesel engine. 5. The above combined panel mounted over MS channel fabricated frame with cement concrete platform, all other connection works carried out as per standard methods and including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers.

1

-

-

... More
FIRE ALARM SYSTEM

-

-

-

... More
Addressable Fire Alarm Control Panel (4 Loop Panel) consists of display board which will have 160 Character Display with Touch key pad, Mother board 32 Bit Processor, In-built RS-485 Networking Circuit for peer to peer networking, In-built USB 2.0 Port, Loop Card having 254 devices of both detectors and modules in a single line circuit, SLC supports both Class A and Class B wiring Approval: UL Listed

1

-

-

... More
Addressable Detectors (Multi Sensor - Heat Cum Smoke detector) with base with Binary coded address setting. Dual LED’s for 360° visibility (Based on SOR rates M-2410)

64

-

-

... More
Addressable Manual Call Point - Resettable type - with back box with Binary coded address setting with Status LED for 360° visibility. (Based on SOR rates M-2413)

7

-

-

... More
Conventional type Horn / Strobe wall mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication.

7

-

-

... More
Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications

4

-

-

... More
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.

1199

-

-

... More
POWER SUPPLY : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON,battery Fail,Battery Charging,battery back up etc.

1

-

-

... More
Supplying, installation, testing & commissioning of analogue talk back Unit to initiate audio conversation (both Speaker and mic) with main fire alarm panel including mounting accessories complete as required (with power backup as per standards)

7

-

-

... More
Photoluminescent Signage with printed "In Case Of Fire, Break the glass" of Suitable height letters in red with white back ground and shall be fixed above Manual call points.

7

-

-

... More
Photoluminescent Fire exit Signage at every exit points with lettering( Arrow+Emergency Exit) Double Side Hanging type of Suitable size with contrasting colour from back ground of Suitable Size.

7

-

-

... More
Photoluminescent Signage with printed "Fire extinguisher"- With Symbol, of Suitable height letters in red with white back ground. and shall be fixed at the height of near Fire Extinguisher.

8

-

-

... More
Photoluminescent Signage with printed ``In Case Of fire, Do Not Use List, Use Stair''- With Symbol, of Suitable height letters in red with white back ground. and shall be fixed at the height of near Fire Extinguisher.

7

-

-

... More
Photoluminescent Signage with printed ``Fire hydrant & Hose Reel''- With Symbol, of Suitable height letters in red with white back ground. and shall be fixed at the height of near Fire Extinguisher.

4

-

-

... More
Photoluminescent Signage with Respective Floor Evacuation Plan Showing Exit Point(s),Manual Call piont Location,Talk Back system Loaction,Fire Extinguisher Location,etc.

4

-

-

... More
S.E.T.C of Custom built table top 6 zone micro processor based 1 way announcement console consisting of teleline Preamplifier , 1x priority module ,6 Zone Selector Module , All Call Switch module, Tone Oscillator Module for fire evacuation , press to Talk Switch module, Goose Neck Microphpone, 24 V DC Rectifier Module, Power Supply Unit, All Call Relay Moudule etc as required

1

-

-

... More
S.E.T.C of 250 Watts power Amplifier unit with Mic. Inputs, control wires,power cables, etc as required.

1

-

-

... More
Supply,installation ,testing and commissioning of Control module for Flasher/Hooter including mounting accessories complete as required.

4

-

-

... More
HVAC SYSTEM

-

-

-

... More
Notes: * DSR RATE CONSIDERED FROM " DSR & AOR ITEMS FOR VRF/VRV AIR CONDITIONING SYSTEM - 2019 & DELHI SCHEDULE OF RATES(E&M) - 2022 "

-

-

-

... More
DX AHU Supply, installation, testing & commissioning of following capacity of factory fabricated Double Skin Ceiling suspended DX AHU suitable for DOL/star delta starter or VFD, unit fabricated out of extruded aluminium section with 0.8mm pre-coated galvanised steel sheet outside and 0.8 mm plain galvanised steel sheet inside & inbetween with 25mm thick rockwool insulation. Fan section with Centrifugal fan AMCA certified high efficiency DIDW fan, Forward Curved, belt driven with fire retardant flexible connection at fan outlet, polished stainless steel drain pan made out of 18G single sheet etc. The casing should resist the fan and motor noise. Cooling coil section with 6 Row deep copper tubes & aluminum fins EPOXY coated cooling coil. The face velocity across cooling coil shall be limited upto 500FPM. High efficiency 'IE3', continuous duty,IP55 TEFC squirrel cage induction motor suitable for 415±10% volts, 50±3%Hz, 3 phase AC supply. It shall be complete with V-Belt drive package. Supporting arrangement comprising of supporting GI rods, GI channels, dash fastners & vibration isolators. Fan & motor shall be mounted on a common base frame with motor sliding rails & complete base frame mounted on the AHU casing.

-

-

-

... More
The filter shall be cleanable Panel/Flat type. The unit shall be provided with water resistance marine light and limit switch with power & control cabling. AHU control panel/kit shall have controlling ON/OFF operation of external drain pump and marine light with limit switch when the AHU is ON & OFF mode. DX type condensing unit(ODU) of single scroll compressor, expansion valve with AHU Controller / distribution kit of suitable capacity for connecting single or multi VRF ODU to DX AHU, with built in auto restart function, necessary electrical cable, suitable starter., The unit shall be suitable for 415 ± 10 % volts, 50 Hz, 3 phase AC supply, and IP 55 protection. The out door unit shall be installed on M.S.platform or floor mounting with neccessary arrangements duly painted, as per specifications with site condition. Room temprature shall be controlled from AHU thermostat which is connected to the AHU with communication/control cable. Also the manufacturer should provide this cable. Inside AHU internal shall be acoustic lining of 13mm Nitrile rubber with density of 140-180 kg/m3. The unit shall be BMS compatible. TR / CFM / EX.ST.PR.(mmwc) / MERV FILTER / MERV FILTER 20.0 / 7500 / 15 / 8 /14

2

-

-

... More
HIWALL UNIT

-

-

-

... More
Supply, installation, testing and commissioning of DX Hiwall Unit along with suitable inverter based outdoor unit, copper tubes and fittings, gas charging, 2/3 row deep coil, inbuilt drain pump, synthetic filter, fresh air provision and cordless remote control with On/Off, thermostat/romote and fan three speed functions and mounting arrangement with required power and control cable. Also BMS comapatible. The unit sound doesnt exceed to 40dB @ 1m distance. The motor suitable for 230±10% volts, 50±3%Hz, 1 phase AC supply. Necessary supporting arrangements complete as per specifications.

-

-

-

... More
600CFM - 1.5 TR

1

-

-

... More
OUTDOOR UNITS Supply, Installation, testing and commissioning of VRV/VRF inverter outdoor units (side/top discharge), with multi scroll/Rotary compressors (minimum two compressors) with one capacity controlling compressor, special pre-coated fins, panel, corrosion resistant coated condenser, inverter based condenser fan mounted as indicated in the drawing, electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units, having following capacities.

-

-

-

... More
10 HP Outdoor Unit

1

-

-

... More
14 HP Outdoor Unit

1

-

-

... More
Supply, installation, testing and commissioning of the VRF/VRV following capacity, ceiling mounting type, 4-way cassette unit consisting of thermo plastic cabinet, dynamically balanced centrifugal blowers, fan motors, fresh air port, direct expansion type cooling coil, insulated drain tray, prefilters, electronic refrigerant flow control valve, inbuilt condensate drain pump, IR remote , neccessary supports etc.,

-

-

-

... More
3.5TR - 1200CFM

6

-

-

... More
CEILING MOUNTING TYPE CASSETTE UNITS ( HI WALL) Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System., IR remote , neccessary supports etc.,

-

-

-

... More
1.2TR - 600CFM

6

-

-

... More
Supply & fixing of master controller along with required control wiring from controller to outdoor & indoor units. The master controller shall be web operated remotely through IP network. Incase the controller require low voltage supply the required stepdown arrangement shall be part of supply. Only 230V raw power supply will be provided.

1

-

-

... More
Control wiring between indoor and outdoor units with PVC Conduit for VRV & DX units

150

-

-

... More
SECTION C - DUCTING, INSULATION, DAMPERS, DIFFUSERS & GRILLE'S Rectangular GI Ducting Supply, installation, testing & commissioning of factory fabricated completely finished and boxed ducts (including the duct flange). All sheet shall be Class VIII – light coating of zinc, nominal 120 gsm / sqmt surface area including two sides and Lock Forming Quality prime material along with mill test certificates. TDF type flanges with rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts complete with necessary neoprene rubber gaskets, elbows, splitter, vanes, hangers, Hitech supports. The duct sealing requirement shall be of class 'B' to ensure the duct leakage shall not to exceed as per SMACNA leakage class 12. The Duct to be manufactured and tested as per SMACNA standard for Class-500 pascals. The fire rated duct shall be withstand fire rating of 300 Deg.C for 2 hours with UL certified.

-

-

-

... More
GI Ducts:

-

-

-

... More
Thickness 0.63mm Ducting (Duct dimension 1 - 750 mm)

197

-

-

... More
Thickness 0.80 mm Ducting (Duct dimension 751 -1200 mm)

120

-

-

... More
Thickness 1.00 mm Ducting(Duct dimension 1201 -2100mm)

104

-

-

... More
Fire rated GI Ducts:

-

-

-

... More
Thickness 1.00 mm Ducting(Duct dimension 1201 -2100mm)

48

-

-

... More
Duct Thermal Insulation

-

-

-

... More
Supplying and fixing of 13mm thickness duly laminated aluminum foil closed cell Nitrile rubber (Class "O") insulation of density 40 - 60 Kg/Cu mtr, thermal Conductivity shall not exceed 0.037 W/mK at 20 deg C mean temperature suitable for SA Duct, VCD , FD etc.,

183

-

-

... More
Acoustic Lining of Duct

-

-

-

... More
Supply and installation of Duct Acoustic Insulation applied inside of duct work with 25 mm thick open cell elastomeric nitrile rubber insulation(Class "1") of 140-180 kg/m3 density and with K value not exceeding 0.047 W/mK at an average of 20 deg C temperature suitable for SA Duct, VCD , FD etc.,

46

-

-

... More
DAMPER

-

-

-

... More
Volume Control Damper

-

-

-

... More
Supply , installation, testing and commissioning of volume control damper of low leakage type with the outer shell constructed of 18G thick galvanized steel frame and the opposed blade/Leaf with 20G thick GSS. and with necessary GI flanges for connection etc.,

5

-

-

... More
Fire Dampers with fusible link

-

-

-

... More
Supplying, fixing, testing and commissioning of fire dampers in complete as per specifications and requirement drawings.The damper shall be made outoff 16 G galvanished Sheet metal blades with 16G Galvanized sheet frame with fusible link. Fire Dampers shall meet the fire resistance rating of 2 hours as per UL555.

2

-

-

... More
Grille's, Diffusers and Louvers ( Colour as per Architect/ Client approval) (Grilles, diifuser, louver sizes are to be finalized by approved shop drawings)

-

-

-

... More
SA Diffuser

-

-

-

... More
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Supply air diffuser with aluminium volume control dampers , tegular type & removable core as per drawing/specification.

4

-

-

... More
RA Diffuser

-

-

-

... More
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Supply air diffuser without volume control dampers , tegular type & removable core as per drawing/specification.

4

-

-

... More
FA Grille

-

-

-

... More
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Fresh air grille with volume control dampers , tegular type & removable core as per drawing/specification.

1

-

-

... More
EA Grille

-

-

-

... More
Supply,installation,testing & commissioning of Powder coated extruded Aluminium Exhaust air grille with volume control dampers , tegular type & removable core as per drawing/specification.

1

-

-

... More
FA Louver With Wire Mesh

-

-

-

... More
Supplying & fixing of Fresh air intake louvers comprising of inclined blade & extended out blade for disposal of rain water, bird screen suitable for outdoor application (Aluminium extruded only) as per specification and sizes will be as per shop drawing.

2

-

-

... More
EA Louver With Wire Mesh

-

-

-

... More
Supplying & fixing of Exhaust air intake louvers comprising of inclined blade & extended out blade for disposal of rain water, bird screen suitable for outdoor application (Aluminium extruded only) as per specification and sizes will be as per shop drawing.

1

-

-

... More
Air Transfer Grille

-

-

-

... More
Supply of Powder Coated Extruded Aluminium Air transfer door grilles with rear side frame as per approved shop drawings.

1

-

-

... More
Disc Valve Diffuser

-

-

-

... More
Supply,Installation,Testing & Commissioning of following dia. Exhaust Disc Valve diffuser with powder coated made of galvanised sheet material as per shop drawing.

-

-

-

... More
150mm Dia.

15

-

-

... More
Canvass

-

-

-

... More
Supply and installation of 150mm length fire retardant double layer silicon flexible canvass connection for indoor & outdoor units to connect duct with 250 Deg.C. temprature withstand and canvass sizes's suitable for the units as per drawing/specification.

4

-

-

... More
Under Deck Accoustic Insulation.

-

-

-

... More
Supply and installation of Acoustic Insulation applied on ceiling/AHU room walls with 25 mm thick open cell elastomeric nitrile rubber(Class 'O') insulation of 140-180 kg/m3 density and with K value of 0.047 W/mK along with complete required supports as per specifications. Insulation shall be with Class.1 fire classification.

550

-

-

... More
Cable Tray

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I. bolts & nuts, etc. as required including tee,reducers,bend etc

-

-

-

... More
300 mm width x 50 mm depth x 1.6 mm thickness

20

-

-

... More
ISMC support

-

-

-

... More
HVAC related outdoor equipments/units shall be mounted on ISMC Channels and Angles. The ISMC channels and Angles shall be applied with two coats of zinc phosphate primer and finally one coat of PU paint shall be applied.

500

-

-

... More
Refridgerant Pipe

-

-

-

... More
Supply and Installation of following thick of Copper pipes (refridgerant pipes) including all fittings like bends, elbows, tees with all internal joint type fittings.The pipes and fittings shall be insulated with following thickness of Closed cell Nitrile rubber insulation (tubuler and factory made ) and finished with FRP / glass cloth lining and coated with 2-coats of Fevicol AC Ductking Lag Coating 5590 or equal fore retardant coating. All piping inside the room ( false ceiling ) shall be properly supported in hanger and exposed piping shall be properly supported in cable tray. ( Cable tray quantity quoted separatly & pipes qty only applicable for DX AHU & VRF units )

-

-

-

... More
Soft drawn - 0.8mm thick tube

-

-

-

... More
6.5 mm Dia - 13mm thickness of insulation

55

-

-

... More
9.5 mm Dia - 13mm thickness of insulation

84

-

-

... More
12.7 mm Dia - 13mm thickness of insulation

61

-

-

... More
Soft drawn - 1.0mm thick tube

-

-

-

... More
15.9 mm Dia - 13mm thickness of insulation

75

-

-

... More
19.1 mm Dia - 13mm thickness of insulation

71

-

-

... More
Hard drawn - 1.2mm thick tube

-

-

-

... More
22.2 mm Dia - 13mm thickness of insulation

14

-

-

... More
28.6 mm Dia - 19mm thickness of insulation

13

-

-

... More
34.9 mm Dia - 19mm thickness of insulation

69

-

-

... More
Testing & Gas charging

-

-

-

... More
Gas Charging and Testing & Commissioning for DX AHU & VRF units

1

-

-

... More
Refnet

-

-

-

... More
Supply and installation of indoor and outdoor units of refridgerant pipe branch kit joints / refnet connections with above mentioned insulation specification and thickness for liquid & suction line with properly supported or laying in cable tray. ( 1 set = gas & liquid ) ( Cable tray quantity quoted separatly)

10

-

-

... More
Condense Water Drain Pipe

-

-

-

... More
Supply and Installation of following dia. sizes of UPVC schedule 40 for pipes and schedule 80 for fittings conforming to ASTM standard including all UPVC fittings like tees, elbows, bends, unions, coupling, reducer tees, collars,supports etc. The work shall include cutting, jointing with solvent cement , making holes, fixed on the wall in vertical shafts / terrace with fabricated MS brackets of suitable size with GI 'U' clamps, bolts, nuts and GI washers including. Drain pipe insulated with 13mm nitrile rubber and finished with FRP/glass cloth lining finished with polyshield coating etc.

-

-

-

68

-

-

... More
SECTION D - VENTILATION UNITS

-

-

-

... More
Outdoor Fresh Air Cabinet Fan

-

-

-

... More
Supply, installation, testing & commissioning of double skin floor mounted / ceiling suspended, sectionalized construction, outdoor construction, suitable for fresh air ventilation as per specifications and complete with the following: Fan section with DIDW Centrifugal fan, AMCA certified high efficiency fan, Forward Curved blower with fire retardant canvass connection and prefilter at fan inlet. Motor suitable for 415±10% volts, 50±3%Hz, 3 phase AC supply. Fan & motors shall be mounted on a common base frame with motor sliding rails & complete base frame mounted on the ventilation unit casing with vibration isolation spring isolators.The ventilation unit selection shall be: 4600CFM. External Static Pr : 20mmWg

1

-

-

... More
Circular Inline Exhaust Fan

-

-

-

... More
Supply, Installation, Testing and Commissioning exhaust air system, ductable circular inline fan unit having following capacity with respective static pressure and flexible connections for both sides complete suitable to operate on 1ph, 230 v, 50Hz, A.C. supply. The ventilation unit selection shall be:

-

-

-

... More
360CFM. External Static Pr : 15mmWg

2

-

-

... More
480CFM. External Static Pr : 15mmWg

1

-

-

... More
770CFM. External Static Pr : 15mmWg

1

-

-

... More
1360CFM. External Static Pr : 15mmWg

1

-

-

... More
Circular Inline Fresh Air Fan

-

-

-

... More
Supply, Installation, Testing and Commissioning fresh air system, ductable circular inline fan unit having following capacity with respective static pressure and flexible connections for both sides complete suitable to operate on 1ph, 230 v, 50Hz, A.C. supply.

-

-

-

... More
The ventilation unit selection shall be:

-

-

-

... More
1040CFM. External Static Pr : 15mmWg

1

-

-

... More
1750CFM. External Static Pr : 15mmWg

2

-

-

... More
Kitchen Exhaust Fan Supply, installation, testing & commissioning of double skin floor mounted / ceiling suspended, sectionalized construction, outdoor construction, suitable for kitchen exhaust air ventilation as per specifications and complete with the following: Fan section with belt driven SISW Centrifugal fan, AMCA certified high efficiency fan, backward curved blower with fire retardant canvass connection on both sides. Fan outlet velocity shall be 8-10m/s. High efficiency class 'IE3' motor with class 'F' insulation suitable for either 1 or 3 phase AC supply. Motor shall be suitable for Starter/VFD operation. Fan & motors shall be mounted on a common base frame with motor sliding rails & complete base frame mounted on the ventilation unit casing with vibration isolation spring isolators. The whole fan protection shall be IP55. The ventilation unit selection shall be: (Finalzed capacity shall be done by after approval from the consultant) 5050CFM, External Static Pr : 35mmwc

1

-

-

... More
Kitchen exhaust hood Supplying, installing, testing and commissioning of following size kitchen exhaust hood wall mounted/single island type. The hood shall have following specification of material of construction shall be SS 304 1.2mm thickness, SMACNA complied construction, seamless welded finish for watertight construction, no sharp edges and well ground surface for safety, heavy duty SS angles to join hood pieces, UL certified baffle/greese filters for maximum containment of grease, smoke proof single phase light fitting with toughened glass, quick connect rigid collar for exhaust, sliding damper for fine balancing of air flow, inclined Grease channel to collect oil entrapped by filters, deflection lip to redirect smoke towards the capture area, pheriperal stream contain the fumes within the hood, concealed drain pan to collect oil from drain channel, universal mounting bracket for quick erection, junction box for terminating tube light wiring, easy cleaning accessibility of grease laden areas. Size of opening for the duct shall be as per site condition. Hood size (sq.m.) filter size 20, 500Lx500Wx50H

1

-

-

... More
150mm Wall Mounted Exhaust Fan Supply, installation, testing & commissioning of factory fabricated 150mm Wall mounted Exhaust units fabricated out of PVC with direct motor driven suitable to operate on 1ph, 230 v, 50Hz, A.C. supply. Description Air Volume CFM Exhaust Air fan 80 CFM

9

-

-

... More
Lift well Pressurization Fan Supply, installation, testing & commissioning of liftwell pressurization of fresh air fan having Vane Axial Fan with impeller having adjustable pitch angle blades and complete with suitable motor & drive assembly. Motor shall also be suitable for fixed Speed drive & shall be high efficiency Class IE3. Motor shall be suitable for 415± 10% V, 3 Phase, 50 ± 3%Hz electrical supply. Fans shall be AMCA certified and outlet velocity shall be 10 m/s. (AMCA 210 for air performance & AMCA 300 for sound). The price shall include all accessories & all necessary vibration isolation system, flexible canvass connections, mounting frames, hangers, supports, nut & bolts etc. Fans shall be AMCA certified. Fans shall be activated from fire signal from fire alarm system. The complete fan assembly along with the motor & drive assembly shall be fire rated i.e. suitable to operate upto 250°C for 2 hours and meet the duty parameters. The pressurization unit selection shall be: 7600CFM. External Static Pr : 20mm Wg

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.