Chennai Metropolitan Development Authority Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Chennai Metropolitan Development Authority Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date25 Jun 2024
Closing Date23 Jul 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
The minimum cement content should not be lesser than 400 kg per cum. The rate shall include mobilization of all miscellaous works including necessary pile chipping to the required depth and finishing the top of the pile neatly etc complete in all respects. Likewise, incase of pilegrowing if found necessitated during execution the same should be done to the required depth including developing the reinforcement also simultaneously to the required length and lap all as directed by the Engineer-incharge. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap)

-

-

-

... More
500 mm dia pile of 1200 KN safe load

1858

-

-

... More
600 mm dia pile of 1800 KN safe load

13522

-

-

... More
Supply and conducting Vertical load testing of piles in accordance with as per IS 2911 (Part- IV) - 2013 etc including supply and installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: After testing and unloading of the superimposed load splaced for the test, the pile should be chipped off 1metre below the ground level.

-

-

-

... More
Initial test

-

-

-

... More
500 mm dia pile of 1200 KN safe load

2

-

-

... More
600 mm dia pile of 1800 KN safe load

2

-

-

... More
Routine Test

-

-

-

... More
500 mm dia pile of 1200 KN safe load

1

-

-

... More
600 mm dia pile of 1800 KN safe load

10

-

-

... More
Supply Conducting Pile integrity tests (PIT) on the piles under each cluster by using a 6 lbs nylon tipped hand held hammer, glueing sensitive accelerometer on top of the pile by petro wax or petroleum jelly after making the pile head smooth and even by disc grinder, providing stage wise and final report along with relevant conclusions etc., as directed by Client / Engineer-in-charge. as per IS 2911 (Part- IV) - 2013 etc

-

-

-

... More
500 mm dia pile of 1200 KN safe load

17

-

-

... More
600 mm dia pile of 1800 KN safe load

16

-

-

... More
Conducting High strain Dynamic load tests at 1M below existing ground level / pile cutoff level as per approved method shall be as per IS 2911 (Part- IV) - 2013 etc .Cost should include preparation of pile head, mobilization of all plant and equipments required for carry out the test as per the approved method.

-

-

-

... More
500 mm dia pile of 1200 KN safe load

16

-

-

... More
600 mm dia pile of 1800 KN safe load

5

-

-

... More
Earth work Excavation

-

-

-

... More
Earth work mass excavation for all foundations in all type of soils and sub soils except hardrock to the required depth for Raft, Pilecap, Retaining walls, Footings, Lift pits, plinth / grade beams, etc,. by mechanical means ( JCB / Hydraulic rock breaker / Poclain etc.,) including manual excavation for the following type of soil / rock as per detailed specification and conforming to safety rules during progress of the work as complete with all respects complying with relevant standard specification.

-

-

-

... More
Rate to include backfilling, leveling, dressing of sides and ramming of bottom with all leads, lifts and filling inside the building plinth level including necessary compaction in layers of 150mm thick each complete as directed and dressing to proper level and graded as required etc, loading, unloading, plant and machinery, hire and fuel charges for tools and plants, shoring, strutting required to keep the earth in position and baling out water, dewatering of all ground, surface and rain water, removal of slurry generated while excavation and keeping the area free from water, removal of loose pockets, slips and falls during excavation and compacting the same, Slinging or supporting pipes, electric cables, royalties, Seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
Note: Rate to include for extra earthwork including authorized working space as per IS 1200 and provision of slopes, space for scaffolding, shuttering, shoring, strutting etc., Additional excavation if required for execution shall not be paid separately. The contractor shall keep the foundations dewatered and also arrange to drain them off by suitable drains and other means and keep the work place free from flooding / water logging and fit for carrying on the work unhindered. The contractor shall give a methodology of shoring, methodology of execution of excavation work and methodology for dewatering for the approval of Engineer-in-charge.The Engineer-in-charge. may suggest any improvements and the entire cost and related expenses for protective measures shall be covered in the quoted rates.

-

-

-

... More
In Grey Brown, Moist,Poorly Graded, Fine & Medium Sand Grains, Loose, Clayey Silty SAND (SC) & Silty SAND (SM), etc.,

-

-

-

... More
0 to 2m depth.

4343

-

-

... More
2 to 3m depth.

58

-

-

... More
3 to 4m depth.

58

-

-

... More
4 to 5m depth.

23

-

-

... More
Earth work in narrow excavation for foundation in all type of soils and sub soils to the required depth for trenches, catch basins, collection chambers ,drains etc,. by mechanical means ( JCB / Hydraulic rock breaker / Poclain etc.,) including manual excavation in for the following type of soil / rock as per detailed specification and conforming to safety rules during progress of the work as complete with all respects complying with relevant standard specification.

-

-

-

... More
Rate to include backfilling, leveling, dressing of sides and ramming of bottom with all leads, lifts and filling inside the building plinth level including necessary compaction in layers of 150mm thick each complete as directed and dressing to proper level and graded as required etc, loading, unloading, plant and machinery, hire and fuel charges for tools and plants, shoring, strutting required to keep the earth in position and baling out water, dewatering of all ground, surface and rain water, removal of slurry generated while excavation and keeping the area free from water, removal of loose pockets, slips and falls during excavation and compacting the same, Slinging or supporting pipes, electric cables, royalties, Seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
Note: Rate to include for extra earthwork including authorized working space as per IS 1200 and provision of slopes, space for scaffolding, shuttering, shoring, strutting etc., Additional excavation if required for execution shall not be paid separately. The contractor shall keep the foundations dewatered and also arrange to drain them off by suitable drains and other means and keep the work place free from flooding / water logging and fit for carrying on the work unhindered. The contractor shall give a methodology of shoring, methodology of execution of excavation work and methodology for dewatering for the approval of Engineer-in-charge. The Engineer-in-charge. may suggest any improvements and the entire cost and related expenses for protective measures shall be covered in the quoted rates.

-

-

-

... More
In Hard Stiff clay, Sandy clay,Stilt, Silty clay, Clayey sand Cemented Stit, Disintegrated rock etc.,

-

-

-

... More
0 to 2m depth.

231

-

-

... More
Supplying and filling in foundations and the area wherever specified with 'approved material' good quality filling materials in plinths, area development etc. wherever specified in layers of not exceeding 150 mm thick including clearing of jungle, bushes, breaking clods, storing, transportation, double handling, watering, compacting each layer with vibratory compactor and at un-accessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content, all leads and lifts, bailing/ pumping out of water to keep site dry while backfilling complete as directed. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
Manufactured sand brought from outside

297

-

-

... More
Quarry Dust Filling

37

-

-

... More
Gravel Filling

150

-

-

... More
Carting away surplus excavated earth available with in the campus, is to be carted to the required locations within the campus. The rate shall include loading into the tipper/ lorry, transporting and unloading, leveling, breaking of clods, consolidating and sectioning the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Rate to include loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

2271

-

-

... More
ANTI-TERMITE TREATMENT

-

-

-

... More
Providing Pre - construction Anti - termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentration under grade slab and grade beam and below the ground level as well as outside all-round the building at plinth level etc as per the instructions of manufacturer and as directed by the Engineer-in-charge. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 or equivalent BS specification. The chemical to be used as insecticide for the treatment shall be Biflex Tc and the application shall be diluted 1 part of chemical Biflex Tc with 49 parts of water to get 0.05% emulsion and strictly in accordance with the manufacturer’s specification.

-

-

-

... More
The work should be carried out by an approved and registered specialist pest control agency only. Tenderer to furnish the name of the proposed specialist firm. A 10 years post application guarantee against defects shall be furnished by the main Contractor. Note : Horizontal plan area at ground floor level of the building will be measured and paid.

-

-

-

... More
The chemical to be used for the treatment and concentration of the chemical solutions should be as laid down in IS - 6313 Part II.as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

6168

-

-

... More
CONCRETE WORKS

-

-

-

... More
Providing and laying Plain Cement Concrete 1:4:8 (1 of cement : 4 of coarse manufactured sand : 8 of hard broken stone jelly) using coarse graded aggregate of 40 mm for leveling course under footing, pilecap, steps, walls, raft, retaining wall, drains, kerb and median, platform etc. including all shuttering materials, labour charges, wastages , mixing, curing compaction, transportation, necessary lead and lifts etc. as complete with all respects complying with relevant standard specification as per IS 456-2000 and as directed by the Engineer-in-charge.

897

-

-

... More
Providing, supplying and laying of plain cement concrete screed using 1:2:4 (1 of Cement : 2 of manufactured sand : 4 of Aggregate) grade of any thickness having 12 mm & down grade coarse aggregate to make up the near by rooms / areas to bring up the two different floor finishes to the common and specified level and also to make up the undulations if any in the existing floor level, including laying the screed with the top to the required line, level and alignment but finishing the top roughly to receive the final layer of flooring of any pattern including all materials, labour charges, wastages , transportation, mixing, curing, compaction, lead & lifts etc. as complete with all respects complying with relevant standard specification as per IS 456-2000 and as directed by the Engineer-in-charge. (Screed Concrete).

234

-

-

... More
REINFORCED CEMENT CONCRETE

-

-

-

... More
DESIGN MIX CONCRETE- M 40

-

-

-

... More
NOTE: RMC SHALL BE PROCURED FROM SITE BATCHING PLANT

-

-

-

... More
Providing and Laying M 40 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins, facia Planter box, binders, basement, retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items.

-

-

-

... More
Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
Foundation & Plinth

142

-

-

... More
Ground Floor

3126

-

-

... More
First Floor

3205

-

-

... More
2nd Floor

3296

-

-

... More
Terrace Floor - 1

878

-

-

... More
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins, facia Planter box, binders, basement, retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items.

-

-

-

... More
Rate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
Foundation & Plinth

3161

-

-

... More
Supplying and fixing of Precast slab RCC 1:2:4 (1 of Cement : 2 of manufactured sand : 4 of Aggregate) for the following thickness using 20mm downgrade size hard broken stone jelly including the cost of molding with perforation of size as per drawing, labour charges, materials, finishing smooth on exposed surfaces, curing, transporting to the site, lead & lifts fixing in position, etc complete but excluding the cost of steel reinforcement and cost of shuttering and as directed by the Engineer-In charge. Rate to include all batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, compaction by vibrator, finishing smooth on exposed surfaces, fixing in position, water tight pointing, curing etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
100mm thick, 450mm wide Precast slab

143

-

-

... More
Supplying, fabricating and fixing in position of steel Fe 550D grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required. Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

2870

-

-

... More
FORM WORK

-

-

-

... More
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., Rate to include all materials, labour charges, wastages , placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

-

-

-

... More
Reinforced cement concrete Column footing, Pilecap, plinth / grade beam, bed blocks, template surfaces, steps, piers, pile cap, raft slab / beams and such other members

7729

-

-

... More
Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members

40714

-

-

... More
For plane surfaces such as rectangular, square columns and chamfered sunshades, top and bottom slab of boxing, kitchen platform, loft and such other structural members

12383

-

-

... More
Vertical surfaces - For all type of walls (any thickness) including, retaining wall, core walls, shear wall, parapet wall, fins, facia, kerb and median etc... for all floors & levels.

1983

-

-

... More
Curved surfaces such as RC walls,sides and bottom of any curved beam, sides of curved slab, lintel,curved sunshade, ramp of any curved shapes and curved slab bottom and sides in elevation features and structures .

427

-

-

... More
For Round ( Circular) Columns

238

-

-

... More
Extra for additional height in centering, shuttering wherever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.30 m (height shall be the dimension as measured from the top of the lower slab / pcc sub base to the bottom of the subsequent upper slab) for every additional height of 1m or part thereof for plan area to be measured Suspended floors, flat slabs, drops, post tensioned slabs, slabs curved in plan to any radius, grid slab, roofs, landings, beams including spiral and curved beams of all radius, post tensioned beams, grid beams, plinth beams, girders, bressumers, cantilevers and balconies. Rate to include all materials, labour charges, wastages , placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

67892

-

-

... More
MASONRY WORKS

-

-

-

... More
Supply and constructing cement concrete solid block 200 mm thick masonry work at all levels in cement mortar 1:5 (1 of Cement : 5 of manufactured sand ) using Portland Pozzolana Cement standard size of 400 x 200 mm and 200 mm thick of solid cement concrete with minimum compressive strength of 5 N/Sq.mm.conforming to IS 2185 or equivalent BS and Fly ash conforming to IS : 3812 (Part III)-1966* may be used for part replacement of fine aggregate up to a limit of 20 percent complete and as directed. Concrete blocks manufactured under strict quality control conditions using modern rugged block casting and stripping machine with the latest moulding techniques etc,. only shall be used. Rate to include all materials, labour charges, wastages for working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
Foundation and Plinth

113

-

-

... More
Ground Floor

816

-

-

... More
First Floor

1159

-

-

... More
Second Floor

1144

-

-

... More
Terrace Floor 1

383

-

-

... More
Supply and constructing cement concrete solid block 100 mm thick masonry work at all levels in cement mortar 1:5 (1 of Cement : 5 of manufactured sand ) using Portland Pozzolana Cement standard size of 400 x 200 x 100 mm of solid cement concrete blocks, with minimum compressive strength of 5 N/Sq.mm.conforming to IS 2185 or equivalent BS and Fly ash conforming to IS : 3812 (Part III)-1966* may be used for part replacement of fine aggregate up to a limit of 20 percent. Concrete blocks manufactured under strict quality control conditions using modern rugged block casting and stripping machine with the latest moulding techniques etc. only shall be used. Rate to include all materials, labour charges, wastages for working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
Ground Floor

204

-

-

... More
First Floor

245

-

-

... More
Second Floor

245

-

-

... More
JOINERY WORKS

-

-

-

... More
Foamed PVC Door Frame and ABS Shutter Providing of Factory made prelaminated FPVC (Foamed Polyvinyl Chloride) Door frame of the size 105x40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 6 Nos. of 50mm long screw. The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners of 3 no's to be provided for each vertical member,GIstiffners of ("U" channel of size 29x9x1mm, 150mm long) -3 no's at hinge point, Frame reinforcement of("U" GI channel of size 46x22x.06mm),Bottom tie rod of ("U" GI channel size of 15x15x1mm) etc. complete as per manufacturers specification for finished item of work. The door frame should be got approved from the Executive Engineer before use on work.

916

-

-

... More
Providing of 35mm thick Factory made Prelaminated ABS (AcrolynitrileButadyne Styrene) Door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32x 32mm - 2 nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32 mm thick high density craft paper honey comb board, sandwiched on both sides with prelaminated ABS sheet thickness of 1.5mm . PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges-3 nos for each shutter, 'D' SS pull handle 200 mm on both sides and SS tower bolt on one side with ISI make complete for finished item of work, complete complying with the standard specification. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
750 X 2100 mm

177

-

-

... More
1000 X 2100 mm

14

-

-

... More
1200 x 2100 mm

59

-

-

... More
1200 x 2400 mm

97

-

-

... More
Providing and fixing of sliding doors channels of Dorma or approved equivalent make for - 35mm thick solid core flush door. Using SLM 80 Sliding Door System for Timber Door, 2.5 Metre Length SLM 80 Accessories - 1 Set, SLM Track, 2 mts length - 1 No, Mortice sliding door 400 claw bolt, prepared for euro profile cylinder with 55mm backset, 22mm sq forend including strike plate in satin stainless steel with 3025 europrofile cylinder with both side key operations and Escutcheons. DORMA flush pull for sliding door, rectangular. Finish - Satin stainless steel all necessary approved hardwares as per manufacturer's standards like approved Sliding gear with tracks and rollers with necessary track cover etc.. Height of the door to be considered as 2100mm.

13

-

-

... More
FIRE RATED STEEL DOOR Providing and fixing of 2 Hrs rating Hollow metal Un-Insulated fire rated doors (Insulated fire door with 30Mins Insulation for stability, integrity & insulation at Emergency exits/ staircase exits only.) as per IS 3614 part-1, for stability and integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire, third party certified, for maximum rating of 120mins, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory of approved manufacturer.

-

-

-

... More
a) Door Frame :Door frame shall be Double rebate grooved profile of size 143 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.

-

-

-

... More
b) Door Shutter : Door leaf shall be 46mm thick fully flush double skin door, Un-insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware.

-

-

-

... More
c) Infill material: The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door.

-

-

-

... More
d) Finish: Surface of the frame and shutter shall be cleaned suitably & thoroughly with solvents and as per manufacturer’s specification.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test.

-

-

-

... More
Shutters shall be provided with the following : i) No visible screws or fasteners on either face and Internal reinforcement shall be provided at top, bottom and stile edges for desired fire rating. ii) Factory prepared shutter with pre-punched cutouts and reinforcement pads to receive the approved type and make of Hardware and Iron mongery. iii) Pre-drilled hinge plates with hinge guard covers and shutters with locks to have concealed lock box with lock fixing brackets with pre-tapped holes and screws. iv) Reinforcement pad at appropriate location to receive the hinge, vision panel, flush bolt ,locks, Door closer, Panic Bar, etc. as per the approved type and make of Hardware and all as per manufacturer’s design and conforming to Standards. v) Necessary provision / fixing arrangements shall be provided in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electro magnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.

-

-

-

... More
e) Installation : The frame and shutter shall be installed in position as per the methodology described in the Technical specification with necessary accessories, tools & Plants etc.

-

-

-

... More
f) Grouting: Frame shall be pressure grouted with cement slurry 1:3 ratio or filling the pre cast solid block core to the frame profile as approved. The surface after grouting shall be neatly cleaned and to be ensured that there is no scratch in the door frames after grouting. Back fill the frame through holes provided and insert plug in type nylon plugs after cleaning the surface and to suit the frame finish and colour.

-

-

-

... More
H) Special Provision : i) Provision / fixing arrangements to be made in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electro magnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.

-

-

-

... More
iii) All the Materials and hardware specifications proposed for door shall conform to the codes, technical specification and to the bills of quantities. iv) Quoted rate shall be deemed to have considered all the items covered in the specification and drawings, whether explicitly stated or not.

-

-

-

... More
Frames shall be provided with the following : i) Back plates - 3 mm thick on all jambs with provision for anchor bolt fixing to wall openings. ii) Hinge plates 3 mm thick pre-drilled to receive approved type and make of hinges for screw mounted fixing. iii) Factory finish-pre-punched cut outs to receive specified type & make of hardware and iron mongery. All cut outs including hinge plates, strike plates to have mortar guard covers from inside to prevent cement, dust ingress into cut outs at the time of grouting of the frame. iv) Reinforcement pads for fixing of door closer, locks and handles at appropriate location as per manufacturer’s details. v) Plug-in type rubber silencer not less than 2 mm dia shall be provided on the strike jambs for single shutter frames and on the head jambs for double shutter frames. vi) Frames shall be in knock down form with butt joints for bolted assembly at site or as per manufacturers specification with out visible joints/welding marks in frames. vii ) Fire Rated Vision Galss - 200 x300

-

-

-

... More
2Hrs Fire Rated Door Double leaf of size : 2400x2400mm with vision panel Hinges 3090F, 5 Knl, 2 Ball bearing butt hinges size 4" x 3" x 3mm SSS-8 Nos, Fire rated Mortice Dead lock 288, 55mm BS/20mm sq. fornd, SSS-1 No, Escutheions 6612 for Europrofile cylinder SSS-1 No, EP Cyl. 3225, 5pin both side key Length=65mm, SNP- 1 No, Pull handle D type TGDI 300mm, b/b 22dia, in SSS 304 -2 Nos, Door closer TS 73V EN 2-4 with Std. arm-2 Nos, Flush bolt concealed 3101, size 300mm, SSS - Dorma-1 No, Flush bolt concealed 3101, size 600mm, SSS - Dorma-1 No, Clear fire rated glass, 6mm, for 120min (200 x 300mm)-2 Nos, Gasket, Fire rated 4mm thick x 13mm, Black- 4 Rmt, Fire rated seal for grooved frame profile C421 EPDM Black - Hormann-6 Rmt

176

-

-

... More
Double leaf of size : 1500 x2400mm including vision panel 200 x 300 mm, and Panic bar Hinges 3090F, 5 Knl, 2 Ball bearing butt hinges size 4" x 3" x 3mm SSS-8 Nos, One point panic device PHA 2000 - PHA2102, PHA 2105 L=1300mm- 2 No, Fire rated Mortice Dead lock 288, 55mm BS/20mm sq. fornd, SSS-1 No, Escutheions 6612 for Europrofile cylinder SSS-1 No, EP Cyl. 3225, 5pin both side key Length=65mm, SNP- 1 No, Pull handle D type TGDI 300mm, b/b 22dia, in SSS 304 -2 Nos, Door closer TS 73V EN 2-4 with Std. arm-2 Nos, Flush bolt concealed 3101, size 300mm, SSS - Dorma-1 No, Flush bolt concealed 3101, size 600mm, SSS - Dorma-1 No, Clear fire rated glass, 6mm, for 120min (200 x 300mm)-2 Nos, Gasket, Fire rated 4mm thick x 13mm, Black- 4 Rmt, Fire rated seal for grooved frame profile C421 EPDM Black - Hormann-6 Rmt.

69

-

-

... More
Single leaf of size : 1200x2400mm including vision panel 200 x 300 mm, Hinges 3090F, 5 Knl, 2 Ball bearing butt hinges size 4" x 3" x 3mm SSS - 4 Nos, One point panic device PHA 2000 - PHA2102, PHA 2105 L=1300mm- 1 No, Euro profile half cylinder 3005, 42mm Key x Blank, satin finish - Dorma- 1 No, External trim PHT 3905 prepared for euro profile cylinder.- 1 No, Door closer TS 73V EN 2-4 with Std. arm- 1 No, Clear fire rated glass, 6mm, 120min, of size 200 x 300mm- Schott Pyran S- 1 No, Gasket, Fire rated 4mm thick x 13mm, Black- 2 Rmt Fire rated seal for grooved frame profile C421 EPDM Black - Hormann- 6 Rmt

88

-

-

... More
Single leaf of size : 1200x2400mm including vision panel 200 x 300 mm, Hinges 3090F, 5 Knl, 2 Ball bearing butt hinges size 4" x 3" x 3mm SSS - 4 Nos, Euro profile half cylinder 3005, 42mm Key x Blank, satin finish - Dorma- 1 No, External trim PHT 3905 prepared for euro profile cylinder.- 1 No, Door closer TS 73V EN 2-4 with Std. arm- 1 No, Clear fire rated glass, 6mm, 120min, of size 200 x 300mm- Schott Pyran S- 1 No, Gasket, Fire rated 4mm thick x 13mm, Black- 2 Rmt Fire rated seal for grooved frame profile C421 EPDM Black - Hormann- 6 Rmt

21

-

-

... More
FIRE RATED STEEL DOOR Providing and fixing of 1 Hr rating Hollow metal Un-Insulated fire rated doors as per IS 3614 part-1, for stability and integrity. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2 / ISO 834-1 Part 1 / BS476 Part 20 & 22, CBRI / Cerifire, third party certified , for maximum rating of 60mins, in latched /unlatched condition (if used with deadbolts and pull handles). Labled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer Shakti Hormann or approved equivalent.

-

-

-

... More
a) Door Frame : Door frame shall be Double rebate grooved profile of size 143 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.

-

-

-

... More
Frames shall be provided with the following : i) Back plates - 3 mm thick on all jambs with provision for anchor bolt fixing to wall openings. ii) Hinge plates 3 mm thick pre-drilled to receive approved type and make of hinges for screw mounted fixing. iii) Factory finish-pre-punched cut outs to receive specified type & make of hardware and iron mongery. All cut outs including hinge plates, strike plates to have mortar guard covers from inside to prevent cement, dust ingress into cut outs at the time of grouting of the frame. iv) Reinforcement pads for fixing of door closer, locks and handles at appropriate location as per manufacturer’s details. v) Plug-in type rubber silencer not less than 2 mm dia shall be provided on the strike jambs for single shutter frames and on the head jambs for double shutter frames. vi) Frames shall be in knock down form with butt joints for bolted assembly at site or as per manufacturers specification with out visible joints/welding marks in frames.

-

-

-

... More
b) Door Shutter : Door leaf shall be 46mm thick fully flush double skin door, Un-insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware.

-

-

-

... More
Shutters shall be provided with the following : i) No visible screws or fasteners on either face and Internal reinforcement shall be provided at top, bottom and stile edges for desired fire rating. ii) Factory prepared shutter with pre-punched cutouts and reinforcement pads to receive the approved type and make of Hardware and Iron mongery. iii) Pre-drilled hinge plates with hinge guard covers and shutters with locks to have concealed lock box with lock fixing brackets with pre-tapped holes and screws. iv) Reinforcement pad at appropriate location to receive the hinge, vision panel, flush bolt ,locks, Door closer, Panic Bar, etc. as per the approved type and make of Hardware and all as per manufacturer’s design and conforming to Standards. v) Necessary provision / fixing arrangements shall be provided in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electro magnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.

-

-

-

... More
c) Infill material: The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 6mm clear borosilicate fire rated glass of relavant rating of the door.

-

-

-

... More
d) Finish: Surface of the frame and shutter shall be cleaned suitably & thoroughly with solvents and as per manufacturer’s specification. Apply pure ploystrene powder coated to any RAL shade / wood stained to withstand 500 hours of salt spray of approved colour and make.

-

-

-

... More
e) Installation : The frame and shutter shall be installed in position as per the methodology described in the Technical specification with necessary accessories, tools & Plants etc.

-

-

-

... More
f) Grouting: Frame shall be pressure grouted with cement slurry 1:3 ratio or filling the pre cast solid block core to the frame profile as approved. The surface after grouting shall be neatly cleaned and to be ensured that there is no scratch in the door frames after grouting. Back fill the frame through holes provided and insert plug in type nylon plugs after cleaning the surface and to suit the frame finish and colour.

-

-

-

... More
H) Special Provision : i) Provision / fixing arrangements to be made in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electro magnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.

-

-

-

... More
iii) All the Materials and hardware specifications proposed for door shall conform to the codes, technical specification and preamble to the bills of quantities. iv) Quoted rate shall be deemed to have considered all the items covered in the specification and drawings, whether explicitly stated or not.

-

-

-

... More
Single leaf of size : 750x1800 Hinges 3090F, 5 Knl, 2 Ball bearing butt hinges size 4" x 3" x 3mm SSS- 3 Nos, Mortise Shaft Lock 8681 with Allen Key SSS-Dorma- 1 No, Flush handle, 4207, 120mm x 40mm, Oval, SSS-Dorma- 1 No, Clear fire rated glass, 6mm, 120min, of size 200 x 300mm - Schott Pyran S-1 No, Gasket Fire rated 4mm Thick x 13mm , Black- 7 Rmt, Fire rated seal for grooved frame profile C421 EPDM Black - Hormann-6 Rmt

172

-

-

... More
Fire rated Glass door - Lobby Providing and fixing of insulated glazed fire door for stability, integrity (E/EW 120) & Insulation (EI 30). Pressed galvanized steel confirming to IS 277 with the following specification. Glazed door shall be tested as per IS 16947, IS/ISO 3009-1 for integrity & insulation (E/EW 120) from CBRI/ TBW / Exova Certifier for maximum rating of 120mins with 30Mins insulation and manufactured in ISO 9001: 2015 certfied company for quality management. Test certificates should be made available for max door size tested as a complete assembly including assessment report for side partition for max glass size. Proper label confirming the type of door and the hourly rating is mandatory.

-

-

-

... More
Door frames and partitions shall be single rebate frame profile of size 125 x 60mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be butted/mitered and with mandatory EPDM smoke seal and field assembled with self tabs. All transom profiles and side panels shall be from similar profile and should be as per the tested specimen. For partitions, glass should be held in its place with 1.2mm GI clip-on beading 19mm height with ceramic tape of size 4 x 13mm as per test evidence. Concealed screws shall be of size 8 x 19mm, self tapping and fixed inside the beading at every 250 m c/c. Door frames shall be with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. The top support formounting shall be included as per design requirement. Once frame installed should be filled with PUF (paid extra) as recomended by the manufacturer or engineer.

-

-

-

... More
Door leaf shall be fully glazed SH100 profile of size 60 x 100mm profile step box section for taking glass elements. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. Glass should be held in its place with 1.2mm x 19mm GI clip-on beading with a ceramic tape of size 4 x 13mm as per the test evidence. Concealed screws shall be 8 x 19mm, self tapping and fixed inside the beading at every 250 m c/c a. Doors shall be 60mm thick and the internal construction of the door should be rigid reinforcement pads for stability of profile & infill of high density mineral wool. All provision should be mortised, drilled and tapped for receiving appropriate hardware. For pair of doors integral astragals has to be provided on the meeting stile. The glass shall be fire rated, ultra clear, interlayered minimum 11mm thick pyran fusion, for (E) 120 minutes integrity & (EI 30) 30minutes insulation with light transmission of minimum 89% as per EN1363 and EN1364. Glass shall have a impact resistance of 1B1 as per EN 12600 and sound insulation of 37db. Glazing kit to be provided along with steel beeding and ceramic tape.

146

-

-

... More
Rolling Shutter - With Gril - Gear Operated Type Supplying and fixing rolling shutters with grill of approved make, made of required size M.S. laths of size 80 x 1.20 mm interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation with rolling grills to the suitable size and shape etc complete including the cost of providing and fixing necessary 27.5 cm long good quality wire springs grade No.2 and M.S. top cover of 1.20 mm thick for rolling shutters. The rate shall be inclusive of one coat of red oxide primer and two coats of synthetic enamel paint of approved quality and colour. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

60

-

-

... More
SEMI UNITIZED GLAZED SYSTEM : Design the Semi unitized structural Glazed Punched / Strip window system with extruded alumnium sections and with Glazed Unit / louvers / Openable Panels as per design intent and prepare shop drawings as per approved Design intent / concept drawings, install to any shape & Profile, supply of all materials and fabricate the panel with the specified glass at Factory on the child / sub /Sash frame and erect the glazed panel with Main frame & Transom with Toggle cleat at site over the Floor/Face mounted & back to back / Hook on Bracket with shear key & Bolts and with specified type of anchors at site at all floor levels & at any heights and all shall be as per approved shop drawings. framing shall not be screwed directly on the Masonry or Concrete surface under any circumstances.

-

-

-

... More
In general, the framing system shall have Main (Mullion & Transom) & Child frame (Continuous on all 4 sides) in the Semi unitized system to support Vision panels (Insulated Glass - Digitally Printed) with Top hung window panels to any shape & profile. System shall be provided with smoke seal, flashing, EPDM barriers / Silicon gaskets, weather Gasket / Silicon on the Groove and all necessary accessories, as part of the system and supported with brackets between RC Members etc.complete. Main Brackets shall have span not be more than 3.4 to 3.6 m (for Glazing) with aluminium extruded Toggle cleats at spacing not exceeding 450 mm C/C (max). In General, the Semi unitized Glazed windows shall have 3 stage EPDM Barrier as Primary and Silicon at Groove as secondary barrier with the specified groove width and with Full Mullion & Transom on the complete system.

-

-

-

... More
In general, the complete system including openable shutter shall be designed to with stand design wind pressure of 230 Kg/Sqm (wind Speed - 49 m/sec), confirming to IS 875 part 3 and other load parameters & Seisemic drift as specified in relevant codes. Indicative extrusions to be considered in the system are : Main Mullion & Transom - Jindal Product code - 35872 - 157*67.5*49.55/33.80- 2 mm thick - 2.952.Kg/M. Sub / Child Frame - Jindal Product code - 35874 - 56*26.25- 1.5 mm thick - 0.818 Kg/M. Toggle Cleat - Jindal Product code - 35879 - 18.50*17.50- 2.7 mm thick - 0.238 Kg/M. Spacing at 450 mm C/C. Pheripheral Sealing - Inside : L angle of size 40 mm by 20 mm - 1.5 mm thick shall be considered to fix alround the Glazing with Weather silicon between face of the Mullion / Transom & L angle. Outer profile shall also be the same size of Mullion & Transom and no half mullion & Transom are to considered. Weight of Aluminium frame for the system may be in the range of 8.0 to 8.5 Kg/Sqm, subject to considering the minimum performance barrier system as specified above with Silicon barrier in the groove as additional barrier and meeting the Design & strucural creteria & as per standards etc complete.

-

-

-

... More
Glass A : Provide Insulated Glass (DGU) with 24 mm thick with 6 mm thick Reflective coated glass on # 2 surface ie. ST 167 of Saint Gobain make or Guardian or equivalent Asahi make as outer pane and 12 mm air gap with Black anodized spacer with dry dessican fill and 6 mm thick Clear Glass as inner pane. Glass panes shall be heat treated as specified. The glass performance, processing, thickness and coating of glass and other parameters shall be considered as specified. In General, VLT shall be in the range of 60%, SF – 0.35 and U Value – around 3 W/Sqm Deg K or less. Secondary seal shall be structural silicon sealant of Dowsil 995 (one part) or Dowsill 983 (two parts) and Primary Seal of Dowsil – 335 Butyl Sealant of Dowsil or approved equivalent.

-

-

-

... More
Glass B : Specification same as above with DGU 24 mm , but the Inner pane shall have InnoVink Digital print coating as per the pattern shown in the drawing. Digital print shall be carried out with the approved processor and using the Ink for digital print with Impagranted - Dip methodology by using Digital printing machine of GPI series of Dip TECH or equivalant system, using the durable Ferro inks (Ceramic) printed with multi coloured pattern, textures etc and heated the coated glass in oven upto 700 deg after coating etc complete, as directed. Colours proposed to use in the print should not contain voluntary additions of Heavy Metals like Pb,Cd,Hg and Cr6 etc and should prevent bird collision etc and also pollution free system.

-

-

-

... More
System design in total, includes Aluminium extruded frames, type & thickness of Glass pane, Aluminium sleeves at connections, inserts, EPDM Gaskets / Silicon rubber, Adhesive tapes, Sealant, Supporting system / bracket including fastening and anchoring system & Materials etc shall be as specified in the schedule. The system details as shown in the tender drawing are only tentative and is meant to set out a general outline of the Proprietary system and minimum requirements/ properties of the system and component parts. The general guidelines governing, the system design and performance parameters as set out in the Specification relating to External Façade System and the contents therein. Since the External Façade system in terms of Design, materials, all fixing details, methodology of execution are proprietary in nature, the onus of the design and Performance requirements, shop drawing, execution etc satisfying the design intent and specification of external facade system including conducting the site survey prior to and after preparation of shop drawing and accommodating building tolarances as per site conditions in the system, fabricate and install the panels at appropriate levels etc lies solely with the Facade Contractor.

-

-

-

... More
In general, Designing, providing and fixing Semi unitized structural glazing / Structurally Glazed punched windows with vision panel & vision on spandrel panel and Spandral panel structurally held in position by Structural sealant and with factory fabricated with Aluminium adaptor of suitable size in order to satisfy the structural design criteria. The system comprising Aluminium anodized or Exterior grade - SDF Powder coated extruded frames & Adapters supported on the Face mounted brackets, Toggle cleats at spacing not exceeding 450 mm, Alum. Anodized / HDG brackets & SS anchors - HST 3R / HSA R - SS 316 grade and M 10 Bolt 100 mm long with Serrated washers / Cap nut between bracket and frames etc. Provide GI Flashing - 1.2 mm thick for Smoke seal at Sill level and Beam soffit level and at consealed areas wherever is required and as appropriate. Provide Aluminium flashing with minimum 100 mm overlap at Joints for the exposed surafces as per the drawing and between the civil structure and Glazed frame. provide smoke seal at sill level & Beam soffit level horizontally with compressed Rock wool insulation and Aluminium L angle vertically between the Column and system gap. Aluminium surface shall be finished with Exterior grade - SDF powder coated (20 years warrenty) not less than 70 microns etc complete as and where is required.

-

-

-

... More
In general, Sealant for Glazing shall govern to : Structural sealant shall be : Dowsil - 795 (Two part) at Factory use with Pump. Dowsil - 995 (single part) at site or factory use. Weather sealant shall be : Dowsil - 791 at consealed and exposed area - Factory & at site - Metal to metal or metal to Glass. Dowsil - 789 P at pheripheral exposed area at site betwen metal and Masonry wall. Dowsil - 991 at consealed and exposed area - Factory & at site - Metal to Stone or stone to stone. Bite Size - To be designed as suitable for the member size, glass thickness, dead and service loads as specified. Bond breaking Baker rod of suitable size of supreme make shall be used as filler material prior to application of Silicon.

-

-

-

... More
Rate shall exclude supply of Hardwares for top hung window and spandral insulation with both side sheets, but the fixing of the same as part of the Glazing system as above etc, complete. providing all the harwares in the Top hung openable shutters and subframe as part of the shutter, Compresssible Gasket, weather bar / strips and provision for Spantral tray installation as required shall be measured separately under the respective item below. Rate shall include the cost of fixing the glass, fixing the window with the specified Top hung window hardwares, provision for Insulation tray in spandral area, aluminium mullion and transom (full Mullion and Transom shall only be used in the entire Glazing / Glazed windows) and field water test etc complete.

-

-

-

... More
Rate shall include the cost of all materials and labour involved in all the operations as specified above for the Glazing, Glazed Windows etc, to execute the work as per approved shop drawings & design Creteria as specified including scaffolding, infrastructure facility, tools and plants etc. necessary for execution of the respective item at any height and at all floor levels and elevations etc complete.

-

-

-

... More
i) Glazing with Vision Panel - Max Panel width not exceeding 1100 to 1250 mm and height 2100 to 2400 mm with DGU - 24 mm thick with 6+12+6 mm - Airgap with Black Spacer as described above and as per drawing. Product Code : ST 167 of Saint Gobain make. (Clear substrate) Clear 70 of Solar plus series of Guardian make. Note : Stepped DGU is not allowed / recommended to use.

325

-

-

... More
II) Glazing with digitally printed Vision Panel - Max Panel width not exceeding 1100 to 1250 mm and height 2100 to 2400 mm GU - 24 mm thick with 6+12+6 mm - Airgap with Black Spacer as described above and as per drawing. Product Code : ST 167 of Saint Gobain make. (Clear substrate) Clear 70 of Solar plus series of Guardian make. Note : Stepped DGU is not allowed / recommended to use.

675

-

-

... More
Hardware for top hung window: Quote extra rate over & above the Semi Unitized Glazing/punched strip Window system item suitable for DGU/SGU for designing meeting the design load as specified and wind load 175 kg/Sqm and supplying of hardware's suitable for top hung openable outward shutter having Heavy duty Multi point lock with required points (Minimum 6 Points - 2 Nos on each side and 2 nos at bottom member) based on the window panel size and handle with key type or with detachable handle of Model no 710 K - Heavy Duty of Alualpha make or approved equivalent make, locking point on the sides shall have - Typhoon lock (1 no on each side and 2 nos at bottom) and sliding lock (1 no on each side), SS friction hinges of Model no SPT 26 (above 1.5 M Height) or SPT 22 W for lesser heights, Corner Transmission Model no 9312, corner locking point model no 9313 and restrictor stay arm assembly model no SRD 8 with release key of model no R 7437 of Securestyle (UK) make or approved equivalent make. Rate shall exclude cost for supplying and fixing of glass and main frame, but include cost of hardware's and sub frame for shutter. Maximum shutter height 1500 to 1800 mm shall be considered.

30

-

-

... More
Insulation for Spandrel: Extra rate over & above the glazing item for designing, providing and supplying of Insulation with Back pan having Mineral wool slab - 50 Kg/cum - confirming to EN 13501-1) and having 'K' value of 0.035 w/Mok - 50 mm thick - Thermal Rock of Rockwool India & Middle East make confirming to ASTM 177, 518 / IS. 3346) laminated between 1.2 mm GI Poder coated tray on both sides with fold alround to a height of 25 mm minimum to fix the stiffener flat and as thermal insulation to be fixed behind Spandrel area (Glass / Metal) as mentioned. In both trays, only exposed surface shall be powder coated as per approved colour - Ext.Grade - SDF - not less than 70 Microns. All the edges between treated tray and frame to be sealed with Non-Staining weather silicon sealant - Dowsil 791 of approved make. Tray system to be designed to with stand design wind pressure as specified confirming to IS 875 part 3 and other load parameters specified in relevant codes. Beam Behind surface.

90

-

-

... More
Door System and Glass with Hardwares for Framed Door: Designing, providing and fixing colour anodized aluminium Swing Door- Double / Single Leaf fabricated as per drawing and fixed as part of Glazing system and at all levels, elevations and heights. Aluminium outer box frame shall be fixed into Glazing Profile / Window Profile / wall / RC by using SS anchor fasteners of Hilti make or approved equivalent. All aluminium sections shall be 63400 (H9) grade conforming to IS 8147. All aluminium sections shall be finished with Exterior Grade Powder coated - SDF not less than 70 Microns and weight ratio joints mitered adjoined with heavy duty aluminium pressure die cast cleats with fins to match the sections of frames. All glass panels shall be fixed by using snap fit aluminium colour anodized beading with special water proof cascades, Neoprene, hardwares etc. complete, as directed. Door shall be provided with necessary hardwares such as Door closer - ITS 96 EN 2 - 4 or TS 91 EN 3 (Opening restrict to 85 deg), Narrow style Mortise dead lock - Model No. 278 (both side key operation) SS forend and SS strike plate (Suitable for both single / double leaf shutter) of Satin finish - Grade SS 316, SS satin finish handle - TG9377- 25 (Angled Spacer) or H type Handle - 600 mm long or with back to back bolts in SS 316 grade, Flap butt hinges - 3 or 5 Flap as per the shutter width (Minimum 4 Nos / Shutter), SS Door stoppers floor mounted, Door buffers etc. complete and as directed. All Hardwares shall be Dorma / Kinlong / Geze Make.

-

-

-

... More
Rate shall include the cost of supplying & fixing 10.89 or 11.52 mm thick laminated glass having 5 mm thick as outer panel and 5 mm thick as inner panel with interlayer of 0.89 mm thick sentry Glas of Dupont or 1.52 mm thick DG 41 of Soluztia make. Outer & Inner pane glass shall be Clear glass of approved make. Both panes shall be heat treated and heat soak tested. Complete Door Frame and system to be designed to with stand design wind pressure of 230 Kg/Sqm confirming to IS 875 part 3 and other load parameters specified - Single/Double Leaf.

12

-

-

... More
Fixed Louvers windows / Ventilators / Elevation Feature with Mesh: Design, fabricate as per drawing and fixed at all levels, elevations and heights having a main frame work of vertical and horizontals with Louver in-fill, main frame work shall be out of specially designed approved extruded sections shall satisfy the structural design criteria specified in the technical specification. All aluminium sections shall be 63400 (H9) grade conforming to IS 8147. Main frames shall install into RC concrete surface only with necessary clamps, fastening straps, nuts, bolts, rivets, washers and other fastening materials shall be in stainless steel or aluminium. Section unit weight per running meter is subjected to tolerance on the wall thickness as per IS 6977/ Equivalent BS. Sizes and dimensions are subject to slight variations and for which no extra payment shall be paid. In general, the extrusion details are as given in Particular specification, which are Indicative, but are minimum requirement. Extrusions are finished with Exterior grade – SDF - Powder coating of thickness not less than 70 microns (20 years warrenty) of approved colour. Louver system having aluminium box frame, aluminium flat to receive the louvers and aluminium angles around the louvered window to protect the water ingress through the outer frame etc and to be designed to with stand design wind pressure specified.

-

-

-

... More
In general, Louver Panels shall have 900 to 1200 mm wide with Mesh Panels having Mosquito mesh - 0.6 mm thick colour coated (Black) of PHIFER or RK - ECRAN make. SS mesh shall be fixed on the window with Sash frame and Rollers. Aluminium flashing around the window to be provided with EPDM gasket as weather strip to ensure water and air tightness and shall include providing necessary hardware's like, rollers, concealed locks cum Handle of Giesse / Kinlong make etc. complete. System to be designed as per design creteria and it shall be fixed on the main structure by using concealed aluminium bracket at both top & bottom and install using SS 316 grade HAS – R / HRD anchors with the spacing of anchors for the outer frames at maximum 450mm c/c. All panels are to be fixed with suitable snap fit, aluminium beading and non-staining Hy Brid weather silicon sealant of Dowsil – DC 789 P or approved equivalent make shall be provided at the junctions / gap between wall and main frames after fixing the main frames in position. Quoted rate shall include the cost of Sub Frame and L angle, all type of Extrusions and Louvers as pecified, Fasteners, Silicon, all materials and labour involved in the item for all operation described above.

-

-

-

... More
Providing and fixing complete louver system having aluminium box frame, aluminium flat to receive the louvers and aluminium angles around the louvered window to protect the water ingress through the outer frame etc and to be designed to with stand design wind pressure specified. Support system shall have Storm proof Louver with Mesh backing the Louver Blade of size of 77.6 x 27.6 - 1.7 mm Tk - 0.483 kg/m with suitable flat or F Profile alround the Louvered window and L angle on the Pherpheral to seal with weather silicon as required and to fix the blade profile etc made out of specially extruded aluminium and to be fixed with pitch not less than 50 mm and overlapping shall be 25 mm as minimum as shown in the drawing. Rate shall include the cost of SS mesh as specified, scaffolding, infrastructure facility and all other consumables to execute the work as specified above.

332

-

-

... More
Providing and fixing the EPDM Membrane Seal around the window Jambs externally for 50 to 75 mm wide after the edge of Sub frame and underneath of outer frames using Dow Sil – Membrane Dual and to be bonded with substrate using Dowsil Adhesive 300. Rate shall include surface preparation, and necessary tools and palnts etc complete. Quoted rate shall include the cost of all materials and labour involved in the item for all operation described above and any other stipulations and the rate shall include the cost of scaffolding, infrastructure facility and all other consumables to execute the work as specified above.

200

-

-

... More
IRON AND STEEL WORKS

-

-

-

... More
Providing and fixing pre-polished Stainless steel railing for for 1050 mm height using 50mm dia bent to shape as shown in drawing and 32mm dia for vertical at 600 mm c/c and 25mm dia three bracing bar as per drawing. Rate shall be inclusive of fixing the railing into the concrete surface with necessary hardware's, SS caps, grouting for the same etc. including final polishing, buffing at site complete.(for staircase,balcony,open to sky) and as per drawing SS shall conforming of grade AISI 306. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables, tools and tackles as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

808

-

-

... More
Wall Handrail Providing and fixing stainless steel of horizontal (Straight) 50mm dia (2 mm thk) pipe & maintain a height of 1050mm from finished floor level with 32 mm dia 1.63mm thick with SS steel connector with base plate 100 x 100mm fixed to side of BW / concrete / Partitions with 2nos M10 x 75mm long Hilti /Fischer or approved equivalent make fasteners with SS cover. Rate shall include necessary tools, plants & buffing charges etc complete as directed. All stainless steel pipes conforming to AISI 306 Grade (ie.Non magnetic Grade) and Finishing should be NO 4. Horizontal plan length of 50mm dia Pipe only will be measured as handrail.

548

-

-

... More
Supplying, fabricating, erecting and fixing in position Monkey ladders and all miscellaneous steel works as shown in the drg. or as directed by the Engineer at all heights and levels using MS angles channels, rails, tees, plates, flats, rounds, squares etc., of various sizes and other structural steel sections. The rate shall be inclusive of finishing the MS surfaces shall be painted with 2 Coats (each coat of 25 microns DFT) of red oxide zinc phosphate primer and 2 Coats (each coat of 35 microns DFT) of synthetic enamel paint of approved colour and make Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables, tools and tackles as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

441

-

-

... More
Providing and fixing welded M.S. grills for the window openings and any openings as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall include for two coats of first quality synthetic enamel paint over a coat of zinc phosphate primer, necessary tools & plants, welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Engineer-in-charge.

567

-

-

... More
FLOORING WORKS

-

-

-

... More
Providing and laying in panels not more than 20 sqm. in plan Granolithic flooring with cement concrete 1:1.5:3 (1 of cement : 1.5 of Manufactured sand : 3 of stone aggregate) by using coarse graded aggregate of 6 to 12 mm size laid monolithic with floor concrete and finished smooth with power trowel including preparation of concrete surface and form work. The screed shall be laid for effective separation of panels not exceeding 20 sqm in plan etc and Unevenness in floor finish shall not exceed +2mm in one squaremetre area. Including sprinkling of Nitoflor Hardtop Standard evenly a shake on a ready mixed non-metallic monolithic floor hardening compound with very hard granulates of mineral origin over concrete floor when the concrete in green and touch dry condition at the rate of 5 Kgs/Sqm. Nitoflor Hardtop Standard shall possess a compressive strength of 50N/mm² as per IS: 516-1959, Moh's hardness not less than 8, as per specification and instructions of the manufacturer.

-

-

-

... More
Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, pumping, loading, unloading, preparation of surface, ncessary haccking in RCC surface, power trowel, smooth finishing, fixing of screed dtrips, tools and plants, fuel, curing as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
100 mm thick

9797

-

-

... More
50 mm thick

1064

-

-

... More
Providing, supplying and applying to the designated floor areas shall be surfaced with Nitoflor SL2000 at 2.0 mm thick flow-applied epoxy resin floor topping. The topping shall achieve a minimum compressive strength of 50 N/mm² and a flexural strength of 25 N/mm² at 7 days when tested to BS6319. At 20°C, it shall be capable of accepting foot traffic at 24 hours and vehicular traffic at 48 hours. epoxy topping 2.0mm thick by self smoothing as dust proofing on primed surface of Nitoprime 25 over concrete. Quoted rate shall include necessary material and labour for preparation of the existing surface of floor by light grinding/scarification, cleaning by wire brushing, to remove all dirt, dust, oil etc, to expose clean sound base concrete substrate and joint treatment as per manufacturer's specification ioncluding preparing the existing surface of floor by diamond wheel grinding/scarification and cleaning by wire brushing etc, to remove all dirt, dust, oil etc to expose clean sound base concrete substrate.

922

-

-

... More
Providing and fixing of flooring with quality approved make of Double charged vitrified tiles - Polished / Matt (seamless joint) confirming to IS 13006/EN 176 Group B1a with techical specification as Mohs scratch hardness minimum 7,Water Absorption of less than 0.5%, Modulus of Rupture greater than 35 N/mm2, Deep Abrasion resistant maximum 175 mm 3 Surface flatness, Straightness of sides ± 0.25%, thickness ± 5% of size of approved colour and size & thick as specified below, set in 20mm thick C.M.1:4(1 cement and 4 manufactured sand ) and pointing with white cement to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels and as directed. Rate shall be inclusive of forming pattern as directed by client / Engineer-in-charge. etc; as complete in all respects and complying with relevant standard specifications and as directed

-

-

-

... More
Size of tiles shall be 600 X 600 X 8 mm - Double charged vitrified tiles - Polished / Matt

1278

-

-

... More
Supply and Laying flooring with best quality of Marble slab not less than 18 mm thick and size not less than 1200 x 600 mm of approved colour and pattern set in C.M 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the marble slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, polishing machine and power consumption charges, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

2183

-

-

... More
Supply and laying with best quality the following materials of Machine Polished granite slab for wash basin counter top of 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

96

-

-

... More
Supply and Laying flooring with best quality of Granite slab leather finish not less than 18 mm thick (Steel Grey, Sira Grey, Ruby Red, SK Blue, Raw silk, Antique Brown) of size not less than 1200 x 600 mm machine cut with approved pattern in a single colour/multiple colour and set in C.M 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing rough, medium, nice and tin-oxide polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

1139

-

-

... More
Supply and Laying flooring with best quality approved colour Granite slab Polished finish not less than 18 mm thick (Green teak, Fox brown, Royal brown, Ruby Red and Raw silk) of size not less than 1200 x 600 mm machine cut with approved pattern in a single colour/multiple colour and set in C.M 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing rough, medium, nice and tin-oxide polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

47

-

-

... More
Supply and Laying flooring with best quality approved colour leather Granite slab not less than 18 mm thick in a single piece (Sira grey) for each step for the entire width of the stair, machine cut and machine high pre-polished, set in C.M 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing rough, medium, nice tin-oxide polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, edge moulding anti skid & grooves as per drawing, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

392

-

-

... More
Supply and Laying with best quality approved Kotah stone slab not less than 20 mm thick and the size of slab in general not less than 1200 x 600 mm machine cut and machine high pre-polished, set in C.M 1:4 (1 of cement : 4 of manufactured sand ), 20 mm thick topped with white cement slurry (for surface contact of the bottom of the Kotah slab) as per approved pattern/design as per drawing by using irrespective of size and shape, including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

3508

-

-

... More
Supply and Laying with best quality approved Kotah stone slab not less than 20 mm thick in a single piece for each step for the entire width of the stair machine cut and machine high pre-polished, set in C.M 1:4 (1 of cement : 4 of manufactured sand), 20 mm thick topped with white cement slurry (for surface contact of the bottom of the Kotah slab) as per approved drawing including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over, work at all levels, Rate including all materials, labour charges, wastages , forming pattern, wastage, with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, curing. For Raiser and Treads instead of floor including edge moulding anti skid & grooves with polishing and non slippery stripes etc and as complete with all respects complying with relevant standard specfication as directed by the Engineer-Incharge

1835

-

-

... More
Supply and Laying flooring with designer Cement Concrete Square Tile of size 416mm × 416mm thick not less than 30 mm thick of approved colour / pattern of specified shape & size (as per drg) with grooves, raised chequers of varying size and intermediate flat surfaces, with different levels to provide suitable antiskid features, manufactured by vibration compaction of polymerized concrete conforming to the norms of wet transverse strength, water absorption and wear resistance as per IS 1237, with a minimum of M40 grade concrete laid over a bed of CM 1:4 (1 of cement : 4 of manufactured sand), 20 mm thick including jointed with matching cement slurry, matching corner tile beading and including preparation of base surface.

-

-

-

... More
Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, washing over finished surface, necessary protection and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

132

-

-

... More
Providing flooring with best quality approved make White ceramic tiles ranges, Size of tiles shall be 6mm thick of 300 x 300 mm size set in CM 1:4, (1 of cement : 4 of manufactured sand), 20mm thick and pointing the joints with Laticrete and pointing with Laticrete of approved make and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, and protecting and with Gypsum / POP layer over Plastic sheet and removing the same before handing over, work at all levels etc. as complete in all respects and complying with relevant standard specifications and as directed .( Over Head Tanks & U.G.Sump).

108

-

-

... More
SKIRTING WORKS

-

-

-

... More
Supply and Laying Double charged vitirified skirting 100 mm high of same approved flooring tile set in C.M 1:3 (1 of Cement : 3 of manufactured sand) 12 mm thick and pointing the joints with white cementt compound and matching corner tile beading. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface with necessary grooves, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

107

-

-

... More
Supply and Laying 100 mm high skirting with best quality approved Kotah slab of thickness not less than 20 mm, machine cut and machine high pre-polished set in set in cment mortar 1:3(1 of Cement : 3 of manufactured sand) 12 mm thick . Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, filleting/ chamfering of the edges along with partial recessing of the skirting into masonry including chasing of wall with necessary grooves, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

2748

-

-

... More
Providing 100 mm high skirting with best quality approved granite slab of thickness not less than 18 mm, machine cut and leather finish set in cement mortar at all levels and all as per drawing. Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate also to include filleting/ chamfering of the edges along with partial recessing of the skirting into masonry / gypsum wall.

891

-

-

... More
WALL DADO

-

-

-

... More
Supply and Fixing Dadoing with best quality polished vitrified tile of approved make set in C.M 1:3 (1 of Cement : 3 of manufactured sand) 12 mm thick and pointing the joints with white cementt compound and matching corner tile beading. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
Size of Tile - 300 x 600mm x 10mm

6398

-

-

... More
Providing dadoing with machine cut polished best quality approved colour granite slab (Synthetic grey,Parasise colour) of thickness not less than 20mm of size 1200x600 / 900x600 mm, set in C.M 1:3 ( 1 of cement : 3 of manufactured sand ), thickness not less than 20 mm including pointing with matching colour of Latapoxy SP100 and fixing with stainless steel clamps 6mm dia.and 100 mm long welded with 40 mm and 25 mm long pieces at two ends to right angle, the former with horizontal position to be embedded in brick wall / concrete surface and the later with vertical position to be inserted and caulked in to the holes of the slab, drilled for the purpose, both forming 'T' shape and cement grouted including edge polishing wherever required and forming groove at joints as directed at all levels.

-

-

-

... More
Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, filleting/ chamfering of the edges along with partial recessing of the skirting into masonry, preparation of surface, ncessary haccking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.Rate shall include for preparation of base surface, cleaning, chamfering, edge polishing, with tin-oxide / high gloss factory polish, provision of 'V' shaped notch cuts along the horizontal and vertical joints of specified size as detailed in the drawing protection with Gypsum/POP layer over plastic sheet etc. complete, as directed.

696

-

-

... More
upply and fixing wall dado with best quality approved/equivalent make White Glossy ceramic tiles sizes 300 x 300 mm x 6 mmthick set in CM 1:3 (1 of Cement : 3 of manufactured sand) 10mm thick and pointing with white cement and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, work at all levels etc. as complete and as directed by the Engineer-in charge (For Over Head Tanks & U.G.Sump) Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

94

-

-

... More
Supplying and fixing jet black 20 mm thick granite stone 1200 x 600 mm to shape finished with polished on both sides, slab table rubbed, edges rounded including necessary SS 316 clamps cutting, edge chamfering and polishing etc., for urinal partition and any other partitions. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary cutting in wall surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

94

-

-

... More
PLASTERING WORKS

-

-

-

... More
Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand) according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

29479

-

-

... More
Plastering 15 mm thick for external surfaces with cement mortar 1:5 ratio (1 of cement : 5 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer's Specification with sponge finish (washed sand finish) all complete as per specification and as directed. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge

16231

-

-

... More
Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of fine P.sand) according to the specification. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

32984

-

-

... More
Providing 12 mm thick water proof plaster in Toilet internal walls and over head tank with CM 1:3 1:3 (1 of cement : 3 of fine P sand) with water proofing compound of CICO No:1 or equivalent as per manufacturer’s specification and roughening the surface in green condition with wire brush and clearing of loose particles with sponge brush . Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

9020

-

-

... More
PAINTING WORKS

-

-

-

... More
Supply and painting of two coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer. Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages, cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.(Internal surface)

36665

-

-

... More
Supply and painting in walls and ceilings with 2 or more coats of first quality water proof cement paint of approved make and colour over one coat of priming coat white colour water proof cement paint. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

21691

-

-

... More
Supplying and painting of 2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

4530

-

-

... More
Providing and applying Texture paint finish for exterior / interior surface as per Manufacturers specification and as directed. Application of primer by diluting the texture compound by mineral on the plastered surface and apply final two coats of exterior / interior emulsion on the primer. Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.

12392

-

-

... More
Applying white washing three coats to ceilings and walls with pure shell lime or fat lime conforming to IS-712 all as per Specification including cost of lime, brush etc.. complying with relevant standard specification, as directed by the Engineer-in-charge. .

6818

-

-

... More
WATER PROOFING WORKS

-

-

-

... More
Supply and laying of respective water proofing treatment at below mentioned locations including all below activities. The surface to be waterproofed shall be cleaned to ensure it is free of laitance, loose particles, oily substance which may affect the adhesion of the waterproofing system, using mechanical rotary wire brush and related tools etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, staging, tools and plants, fuel, curing, cleaning, testing, consumables and also include for conducting leakage test at toilet sunken portion and over head tanks by storing water on the sunken continuously for a period of 7 days etc. as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
Supply and laying water proofing treatment on top of PCC laid for Grade slab, Raft, Pile cap ,footing & beam, STP, ETP, UG Sump , Water tank etc., in the following order and consisting of following operations.

-

-

-

... More
i) Supply and applying of one coat of TAPECRETE Acrylic Polymer Cementitious Coating over rendered PCC surface. Application of CORCHEM 206 – I High Build Polyurethane Based Elastomeric Coating to the thickness of 1.5 mm in two coats over TAPECRETE applied surface. Protect the treated area with Cemet concrete 1:2:4, 20mm thick

-

-

-

... More
ii)Supply and Fixing 75 mm long 18 mm dia GI nozzles in the hole of about half the depth of member size in grid pattern at a spacing not more than 1.0 meter c/c while casting the raft slab and along construction joints at a spacing not more than 1.0 meter c/c along the construction joints.

-

-

-

... More
iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement.

-

-

-

... More
iv) Sealing & cutting of the nozzles, and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.

1402

-

-

... More
Supply and applying water proofing treatment on Retaining walls external / internal surface at Basement, UG Sump, STP, ETP, Water tank, Lift pit, Raft sides etc. using cement admixed with water proofing compound in the following order.

-

-

-

... More
INTERNAL

-

-

-

... More
i) Making ' V ' grooves at the construction joints of size 20 x 20 mm and filling the "V" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cement

-

-

-

... More
ii) Supply and Fixing of 50 long 18 mm dia GI nozzles in the hole of about half the depth of member size along construction joints, and honey comb areas at a spacing not more than 1m c/c.

-

-

-

... More
iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement.

-

-

-

... More
iv) Sealing & cutting of nozzles and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.

-

-

-

... More
EXTERNAL

-

-

-

... More
v)Supply and applying one coat of TAPECRETE Acrylic Polymer Modified Cementitious Slurry Coat over well prepared surface as a Primer and applying CICO CORCHEM 206 - I Polyurethane Based Elastomeric Coating to the thickness of 1.5 mm in 2 coats over TAPECRETE slurry coat applied surface.

-

-

-

... More
vi) Lay protective plaster layer with 20 mm thick Cement Mortar 1:4 (1 cement: 4 P sand) admixed with Normal setting integral Waterproofing compound CICO NO.1 or approved equivalent conforming to IS 2645 at the rate of 2% by weight of cement over the third coat of brush topping. Plaster shall be cured by spraying of water for the next 7days. The entire water proofing system shall be protected with a 25 mm thick extruded polystrene with necessary low VOC adhesieve.

707

-

-

... More
Supply and laying water proofing treatment for bottom of over head tanks covering the following order and consisting of following operations.

-

-

-

... More
i)Supply and Fixing 75 mm long 18 mm dia GI nozzles in the hole of about half the depth of member size in grid pattern at a spacing not more than 1.0 meter c/c while casting the bottom slab and along construction joints at a spacing not more than 1.0 meter c/c along the construction joints.

-

-

-

... More
ii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement.

-

-

-

... More
iii) Sealing off the nozzles and level the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.

-

-

-

... More
iv)The concrete slab shall be thoroughly cleaned to remove debris and dust, and application of two coats not less than 2 mm thick of TAPECRETE - RTU Polymer Based Elastomeric Waterproof Coating over well prepared surface. Protect the treated area with C M 1:3, 20mm thick admixed with CICO NO1 @ 2% by weight of cement.

108

-

-

... More
TOILET SUNKEN AREA Supply and laying water proofing treatment for bottom and sides of toilet sunken slab covering the following order and consisting of following operations.

-

-

-

... More
i)Making V groove over the construction joint, beam and slab joint and filling the groove with CICO Quick setting material (CICO NO 3) admixed with cement

-

-

-

... More
ii) Supply and Fixing of 50 long 18 mm dia GI nozzles in the hole of about half the depth of member size along construction joints, and honey comb areas at a spacing not more than 1m c/c.

-

-

-

... More
iii) Supply and Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement.

-

-

-

... More
iv) Sealing & cutting of the nozzles and level the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.

-

-

-

... More
v) The wall surface shall be thoroughly cleaned to remove debris and dust, and application of two coats not less than 2 mm thick of TAPECRETE - RTU Polymer Based Elastomeric Waterproof Coating over well prepared surface

-

-

-

... More
vi) Supplying and laying final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent at the rate specified by the manufacturer over coated surface

1236

-

-

... More
Supply and grouting the gaps around the pipes at any dia should be filed in order to provide a proper bond and the same to be aligned by the respective agency. Clean the entire surface and remove the loose particles from the core area. Minimum of 10mm all around gap to be provided between the pipe and the core Provide shuttering below the core apply one coat of CICO LATEX over the area and fill up the hole with CICO GROUT - GP Polymer Based Non-Shrink Grout and finish the surface smoothly.

20

-

-

... More
Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturer's specification after entire completion of laying pipes, sanitary fittings etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

1179

-

-

... More
Supply and laying water proofing treatment of Curved / Sloped Terrace covering the following order and consisting of following operations.

-

-

-

... More
i) Making ' V ' grooves at the construction joints of size 20 x 20 mm and filling the "V" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cement

-

-

-

... More
ii)Supply and Fixing 75 mm long 18 mm dia GI nozzles in the hole of about half the depth of member size along the construction joints, and honey comb areas at a spacing not more than 1m c/c.

-

-

-

... More
iii) Applying injection grouting through the nozzles grouting pumps with a minimum pressure of 2 kg/sqcm with cement slurry admixed with CICO Non shrink Polymeric Water Proof Grouting Compound or approved equivalent at the rate of 2% by weight of cement .Grouting operations to be taken up after the concrete reached the full strength, i.e. 28 days after casting of concrete.

-

-

-

... More
iv) Sealing &cutting of the nozzles and leveling the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.

-

-

-

... More
v) Curved / Sloped Terrace shall be thoroughly cleaned to remove debris and dust, and application of two coats not less than 2 mm thick of TAPECRETE - RTU Polymer Based Elastomeric Waterproof Coating over well prepared surface. Protect the treated area with C M 1:3, 20mm thick admixed with CICO NO1 @ 2% by weight of cement.

198

-

-

... More
TERRACE WATERPROOFING: Supply and laying water proofing treatment for terrace covering the following order and consisting of following operations.

-

-

-

... More
i) Making ' V ' grooves at the construction joints of size 20 x 20 mm and filling the "V" Groove with CICO No. 3 Quick Setting Waterproofing Compound admixed with cement.

-

-

-

... More
ii) Supply and Fixing 18 mm dia GI nozzles (the hole shall be about half the depth of the member to be grouted and nozzle should be 50mm) the retaining wall, along construction joints, and honey comb areas at a spacing not more than 1m c/c . Nozzles (can also) shall be post fixed by drilling holes using drill machine and to be fixed with cement putty admixed with quick setting integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight .

-

-

-

... More
The roof slab / gutter slab shall be thoroughly cleaned to remove debris and dust, and applying 2 coats not less than 2 mm of polymer based Elastomeric Coating like TAPECRETE - RTU compound and cured for 7 days and followed by a layer of 20 mm thick cement mortar 1:3 admixed with CICO NO:1 (or) other approved equivalent make shall be spread over the prepared surface

-

-

-

... More
On the spread mortar provide and lay well burnt brick bats (COBA) to a average minimum thickness of 55 mm (i.e.. minimum 40 mm thickness at lower end and 70 mm thickness at higher end). An additional layer of brick bat (COBA) shall be laid over the existing brick bat COBA surface if required to get the required gradient for adequate drainage giving a slope of approximately 1 in 120, which will be measured separately under relevant item.

-

-

-

... More
The gap between brick bat shall be filled with cement mortar 1:4 admixed with waterproofing compound like CICO NO:1 or approved equivalent afterwards curing shall be carried out for two days a final layer of cement mortar of 1:3 admixed with water proofing compound like CICO NO:1 or approved equivalent make shall be laid to a thickness of 20 mm and draw a false line of 300 mm x 300 mm.

-

-

-

... More
The parapet side wall / gutter wall shall be thoroughly cleaned to remove all dust particles and a layer of 15 mm thick C.M 1:3 shall be laid to a height of about 300 mm above the top of the terrace/Gutter slab on the Parapet / Gutter side wall admixed with water proofing compound like the CICO NO:1 or approved equivalent make. Providing, supplying, mixing, applying two coats of ready to use two component Acrylic polymer modified cement based, flexible, water proofing slurry like or approved equivalent to a thickness of 2 mm over the plastered surface of operation as per manufacturer's specification and as directed.(Plan area of Terrace only will be measured for payment )

6376

-

-

... More
MISCELLANEOUS WORKS

-

-

-

... More
Supplying, fabricating and placing in position M.S.chequered plate of required thickness of 5 mm for machine floors and shafts closing at all floors at all levels with necessary supports such as M.S. angles/M.S. flats including stiffeners to be placed on angle iron frame work. (Frame work, angles, stiffeners will be measured under relevant structural steel item). Rate shall include making necessary cutouts for inserts, All MS members shall be painted with 2 Coats (each coat of 25 microns DFT) of red oxide zinc phosphate primer and 2 Coats (each coat of 35 microns DFT) of synthetic enamel paint of approved colour and make etc,. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.

5483

-

-

... More
Supplying and fixing Poly-propelene rungs of 25 mm square bar of size 260 x 170 mm for access way including anchorage in walls to a minimum depth of 100 mm with C.C 1:2:4 (one cement,two fine aggregate and four coarse aggregate) etc. complete and as directed by the Engineer-in-charge.( Duct ,Shafts & UG sump,Over Head Tank and wherever necessary) Note: Rungs to be fixed before concreting and necessary provision to be made in the shuttering.etc complete, as directed by the Engineer-in-charge.

40

-

-

... More
Supplying and fixing Ductile Iron manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.

-

-

-

... More
600 X900 mm Heavy duty DI manhole cover

7

-

-

... More
Providing and laying in position the RCC humepipes (NP3) of approved quality and make including collars,. necessary Excavation, PCC 1:2:4 supports, Sand cushion of 150mm on all sides, Refilling with earth, Compaction and making good the level, alignment etc.,complete as directed by the Engineer-in-charge.

-

-

-

... More
Supplying and fixing of 450mm dia NP3 class Hume pipe

147

-

-

... More
Supplying and fixing of 600mm dia NP3 class Hume pipe

137

-

-

... More
Construction of Collection / Inspection chamber 900x800x900 MM with approved 200 mm thick solid block in CM 1:3 over a bed of 100 mm thick PCC1:4:8 and 12 mm thick internal wall plaster smooth in CM 1:3 with water proofing compound of CICO No:1 and 12 mm thick external wall plaster rough with sponge finish in CM 1:3 with water proofing compound of CICO No:1, also providing RCC cover slab of 100 mm thick with 8mm  dia reinforcements at 150 mm ctc bothways top and bottom with required shuttering including curing with sponge finish benching and channeling in PCC 1:2:4 and providing and fixing PVC foot rest etc. complete complying with standard specification and as directed by the Engineer-in-charge.

-

-

-

... More
Size of chamber 900x800x900mm depth

10

-

-

... More
Supply and Fixing Mirror as per drawing, in general 6mm thick mirror with aluminium frame at 600 mm c/c bothways for backing frame fixing with 12MM thick BWP ply wood and fixing with stainless steel studs. Rate quoted shall be for the complete item including all the materials and labour mentioned above. Rate to including all materials, labour chanrges, transportation, lead & Lifts, wastage, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge.

124

-

-

... More
Supply and fixing in position of Hot rolled structural steel Members/ Sections consisting of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, etc. at all levels. Surface preparation of all MS members by Sand blasting to SA 21/2 grade and painted with anti corrosive, PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of PU paint of and total dry film thickness 225 microns Rate to including all Lifts, wastage, cost of bolts, nuts, washers, welding, electrodes and connections required for the work. No extra on this account will be paid for, and the rate to include preparation of fabrication shop drawings for owner's approval. etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge

227811

-

-

... More
Supplying and fixing GI chain link fencing consisting of the following: RCC vertical post 2.6 meters height sizing 175 x 175 mm at bottom and 175 x 125 mm at top spaced at 2.50 M (may vary slightly as per site condition) centre-to-centre made using M20 grade cement concrete using 20 mm and below size hard broken stone with 4 Nos. 12 mm dia. tor steel and 6 mm dia.  MS stirrups at 125 mm centre-to-centre as reinforcement including providing 4 Nos. suitable holes for 12 mm bolts and 2.3 meters height Strut posts of size 125 x 125 mm at every 15 m c/c on both sides and at corners on both sides made using in M20 grade cement concrete using 20 mm and below size hard broken stone with 4 Nos. 10 mm dia tor steel and 6 mm dia MS stirrups at 125 mm c/c as reinforcement.

-

-

-

... More
Supplying and fixing 10 gauge 75 x 75 mm size GI chain link fencing to 2.00 M high above ground level supported on above vertical  post and flat and tied with 3 PLY 10 G - GI binding wire and stiffened the fencing with 3 rows (one at top and one at bottom) including 2.00 M long 50 x 6 mm size MS flat on each vertical post with 4 Nos. 12 mm dia bolt washer and nut. Painting the flat with one coat of  red oxide primer and two coats of synthetic enamel anti-corrosive paint of approved make and shade. The entire work shall be carried out as per specifications and drawings including cost of all materials, labour, form work, reinforcement, fabrication, painting, wastage, curing, tools and plant etc. all complete and as directed.

113

-

-

... More
Providing and fixing weld mesh doors consisting of shutter frame 50 mm dia heavy duty pipe alround, weld mesh size of 50 x 50 10G is fixed to the frame with 25 x 3mm flat with suitable nut and bolts and if necessary tack welded. The shutter is fixed to the vertical post of 2/ISMC 150 box type on both sides and a horizontal at top. Rate shall inclusive of 2 Coats (each coat of 35 microns DFT) of anti corrosive EPOXY polyamide based enamel finish of approved colour and make over a Coat (each one coat 25 microns DFT) of anti corrosive EPOXY polyamide based red oxide zinc phosphate primer and necessary provision for locking arrangements like aldrop, tower bolts and hinges etc,

40

-

-

... More
Floor expansion joints- heavy duty

-

-

-

... More
Providing and fixing floor to floor/ Floor to wallheavy duty expansion joint model no. –XH4FS in accordance with the contract drawing and specifications below. The system is proprietary design consisting of heavy dutyaluminum profiles. The expansion joint includes aluminum frames and centre plate which slides between the frame to accommodate movement for floor to floor condition. The system operates mechanically with snap lock into the frame and able to remain flush at all times during normal movement cycle, particularly at full closure. The system should be fixed with appropriate heavy dutyanchors, fasteners and the exposed surface shall be mill finish as standard. It should be designed for thermal movement and withstand heavy vehicular load. Aluminum to conform as per ASTM B221 for extrusion alloy 6063-T5/T6, and contain moisture barrier for maintaining water tightness. Joint Size: As below

-

-

-

... More
FLOOR TO FLOOR - 50 MM WIDE

270

-

-

... More
FLOOR TO WALL - 50 MM WIDE

228

-

-

... More
TERRACE - 50 MM WIDE

136

-

-

... More
Providing and fixing Heavy duty grating  for trenches, drains and water collection sump etc., of various size of opening in drain trenches made out of galvanized steel and all as per manufacture's specification of approved make including necessary supports, suitable angle iron frames, grouting the supports using C.C 1:2:4 and finishing the surface neatly, welding the angle / Flat with consumables, Painting iron frame with 2 coats of Synthetic Enamel paint over a coat of Zinc phosphate primer etc. complete and all as directed. Note : Clear opening will be measured and paid for.

14

-

-

... More
False Ceiling Works

-

-

-

... More
Supply and fixing seamless ceiling with moisture resistant gypsum board of 12.5 mm thick, fixed to the underside of the suspended grid formed of GI perimeter channel of size 20 x 28 x 30 mm fixed along the wall by using wood screws and metal expansion rawl plugs. The GI intermediate channel of size 45 x 15 x 0.90 mm shall be fixed to the suspended strap hanger / GI ceiling angle 25x10mm at intervals not more than 1220 mm. The suspended GI ceiling angle /. Strap hanger is to be connected with GI soffit cleat of size 37 x 27 x 25 x 1.6 mm and it should be fixed on the roof / beam, by using metal clamp.

-

-

-

... More
The GI ceiling section of size 80 x 26 x 0.51 mm (MF 5) is to be provided across the intermediate channel at intervals of not more than 457 mm centres at bottom and the same shall be fixed by GI connection clips 2.64 mm dia. at the intersection points. The ends of ceiling section (MF 5) channel by adopting an overlap length of minimum 150 mm, connected with intermediate channel shall be fixed to perimeter channel in insertion. The moisture resistant gypsum board shall be fixed to the underside of the suspended grid by using 25 mm long dry wall screws.

-

-

-

... More
Rate to includes for providing and fixing of Hot dip galvanized M.S angle support for false ceiling at under the AC ducts or other equipment where ever required, Using 50mmx50mmx6mm thick of required length supported to the true ceiling through 12mm thick G.I treaded rod with necessary hanger fasteners. complete.

-

-

-

... More
Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes 3 layers of filling and finishing with Moisture resistant gypsum board Jointing compound, Fiber mesh/Paper tape and two coats of Drywall Top Coat. The ceiling surface shall be painted with three coats of approved first quality acrylic emulsion paint (low VOC) over a coat of primer etc. complete. The rate shall include making cutouts for tube lights, cove light, spot lights, duct doors, for specified size, grills, etc. for which no extra will be paid separately.

-

-

-

... More
Rate shall include providing additional color pre-finished polyester paint trims, wall angles, profiles between board and false ceiling tiles, at ends and also for providing additional supports from ceiling where main / cross members are cut for light fittings, AC grills, flexible sprinkler heads etc. and necessary ceiling tile hold-down clips should be installed to counteract excessive wind pressure. Rate shall include vertical as well as horizontal surfaces as per detailed drawing. Actual “seen” surface of horizontal and vertical will be measured and paid for.

390

-

-

... More
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre 'T'. The 'T' shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of 'T' section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of 'T' section are made at required intervals not exceeding 1200mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The last panel shall be placed at the side wall using edge profile 'L' Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look

1334

-

-

... More
AL 0.9mm 75x150mm Torsion Spring U Baffle Plain CC Burma Teak Wood Finish_150 module Supply and Installation of torsion spring-based Roll formed U-Baffle Ceiling System, comprising of baffle width of 75 mm and height of 150 mm manufactured out of 0.9 mm thick wood finish Coil Coated Aluminium of alloy AA 3105 at a module of 150 mm. The coil is coated on a continuous paint line double baked and shall be stove enamelled in a continuous coil coating process with the approved colour on the exposed side and the reverse side with polyester primer. The coated coil is passed thru ARKU SIX Hi configuration roller levelling process to ensure the flatness of the coil. The baffle shall be manufactured on an integrated high speed, high precision Roll forming machine to avoid micro-cracking of metal corners which occurs while bending on press brake machines. The U Baffle ceiling panels shall be mounted on coil coated customized Hat type GI carrier of size 60mm X 30mm X 0.5 mm. The customized carrier shall be suitable for both torsion spring based & standard fixed Baffle panels. The carrier shall be suspended with M6 Threaded rod hangers spaced at 1200mm c/c.

1560

-

-

... More
Road Works

-

-

-

... More
Preparation of sub-grade and compacting with vibratory roller having minimum 8 - 10 ton vibratory power roller static weight to achieve desired density of not less than 98% of MDD including forming camber and gradients watering and rolling to reach required density complete, including all material, labour, watering, machinery with all leads and lifts etc. complete.

4877

-

-

... More
Construction of Granular sub-base (GSB) of specified compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading I of Table 400-1 of MORTH clause 401, mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30% (Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work.

1960

-

-

... More
Providing and construction of Dry Lean Concrete Base course of 200 mm compacted thickness over a prepared sub base with coarse and fine aggregate conforming to IS 383 as per table 600-1 of MORTH specification produced in a batching plant and conveyed in tippers to the laying site with a moisture content as per the design mix and laid with mechanised paver finisher and compacted with a 8-10 tonne vibratory roller to the requisite grade and levels as specified in drawings with adequate curing by covering the surface with hessen cloth and keeping it wet for 7 days. The design mix shall be such that the average compressive strength of each consequetive group of 5 concrete cubes shall not be less than 7Mpa at 7 days. In addition the compressive strength of any individual concrete cube shall not be less tha 5.5 Mpa at 7 days. The concrete mix shall be proportioned with a maximum aggregate cement ratio of 14:1 where OPC is used and 12:1 where PPC or PSC is used. The minimum cement content shall not be less than 140 Kg/Cum of concrete. The rate shall include for all incidentals as specified in clause 601.12 of MORTH

732

-

-

... More
Providing and Construction of dowel jointed, Pavement Quality Concrete of 280mm thickness over a prepared Base Course with 43/53 grade cement , coarse and fine aggregate conforming to IS 383, coarse aggregate 25 mm & 12.5 mm Granite/Basalt/Trap metal & clean sieved approved sand conforming to the gradation as specified in Table 600-3 of MORTH clause 602,. loading materials to cement concrete batch mix plant of adequate capacity ( normally 25% more capacity than the paving equipment preferably 120 Cum/hour ) as per approved mix design satisfying the characteristic flexural strength of not less than M40 grade of concrete with minimum cement content as per IS 456 - 2000.

-

-

-

... More
The mix shall be transported to site in transit truck /tippers/ dumpers of 5-6 Cum capacity, laid with a slip form paver with electronic sensor fitted with vibrators which shall operate at a frequency of 8000-10000 impulses per minute under load with a maximum spacing of 600mm and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, fixing of Dowel bars and Longitudinal tie bars ,joint filler, separation membrane, sealant primer, joint sealant, debonding strip, curing compound as approved, finishing with power trowel to the required grade, level and alignment, textured with texturing machine, finishing, making groove cutting for contraction joint of size (10 X 20 mm) and filling the same with Polysulphide/Polyurethane sealant with paper backed compressible debonding strip, making groove cutting for longitudinal joint / expansion joint of size (8 X 13 mm) and filling the same with Polysulphide/Polyurethane and debonding tape,

-

-

-

... More
providing Isolation joint of 20mm wide to the full depth of the concrete and fixing with isolation pad of 20mm thick and sealing the top with Polysulphide/Polyurethane to the size of 20 X 20 mm and curing (curing shall be as per clause 602.9.12 of MORTH) including cost of all materials, labour, lead and lift, hire charges of machineries , including the initial saw cut and filling of Polysulphide/Polyurethane sealants in contraction, expansion joints etc., complete in accordance with MORT&H technical specification clause No. 602 and with all other incidental charges including the trial length and as per the direction of the Engineer-In-Charge of work. (Reinforcement and Dowel bars shall be paid under relevant item)

1366

-

-

... More
Providing guildeline road marking kerb painting (special acrylic medium pigmented ) involving cleaning the surface free of dirt and loose particles applying one coat of primer and applying one layer of 20 to 25 microns. Rate shall include for all materials & labour components etc., as complete all respects complying with relevant IRC specifications, as directed by the Engineer-in-charge.

630

-

-

... More
PLUMBING AND SANITARY WORKS

-

-

-

... More
SANITARY & CP FITTINGS INSTALLATIONS

-

-

-

... More
Supply and fixing in position white European Water Closet of approved make with low level flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directed by the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.

90

-

-

... More
Supplying and fixing Lipped Mouth Porcelain Flat Back Urinal(white colour) of size 425 x797 mm with all accessories such as 32mm dia Bell Mouth PVC Connection, 15mm dia GM Wheel Value, 15mm dia 'B' Class GI Waste Water Pipe, 15mm dia Nylon Connection, 15mm dia Brass Nipple, and suitable screws, shellac etc., complete. The rate including cost of all materials, labour charges for fixing and transportation etc. completed as directed by Engineer-in-Charge.

150

-

-

... More
Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia ' B ' Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass Nipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers. (The Wash basin should be got approved by the Executive Engineer before use on works.

115

-

-

... More
Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre long flexible tube including cutting and making good the walls wherever required etc complete. complying with standard specification and as directed by the Department officers. The quality and make of health faucet should be got approved by Concern department Engineer before use on work.

101

-

-

... More
Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work.

30

-

-

... More
Supplying & fixing in position 15 mm dia brass/ C.P screw down tape (Heavy duty) of approved make conforming to I.S. Specifications & quality including cost of shellac, thread etc., complying with standard specifications & including cutting & threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the work).

115

-

-

... More
Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers. The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work

126

-

-

... More
Supplying,installing,testing and commissioning of approved make CONCELED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work.

150

-

-

... More
Supplying,installing,testing and commissioning best quality approved/equivalent make of Single Bowl with drain board 600X600X200 mm stainless steel sink with brass Chromium Plateds wivalty peex tended swing sink cock 32mm dia CP waste coupling, 32mm dia heavy duty waste hose with extension pipe, 15mm CP angle valve with CP inlet connection tube,CP wall flange, including necessary bracket set ccomplete complying with standard specification and as directed by the Department officers.The quality and make o fsink and brass CP coated swiv al type sink cock should be got approved by Concern department Engineer before use on work.

3

-

-

... More
Supplying and fixing heavy duty 15mm CP shower unit comprising of CP 15mm dia hot & cold mixer with CP spout, overhead shower set comprising of CP shower arm, rose etc.,complete with CP wall flanges. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge.

3

-

-

... More
Supplying and fixing Brass Chromium Plated Towel Rail 60cm long and 20mm dia with brackets of same materials including cost of teak wood plug & CP screws etc., complying with standard specification and as directed by the Department officers.

55

-

-

... More
Supplying and fixing C.P. Robe hook fixing with necessary screws etc., complete. fixed on the toilet door complying with standard specification and as directed by the Department officers. The quality and make of coat hook should be got approved by Concern department Engineer before use on work.

101

-

-

... More
Supplying and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm using rawl plug & brass screws for fixing etc., complete complying with standard specification and as directed by the Engineer Incharge before use on work.

3

-

-

... More
Supplying & fixing of approved make GEYSER with necessary fittings. (20 Litres Capacity) Heating element 2 kw ( Rate as per Quote )

3

-

-

... More
Supplying, Installing, testing and commissioning of White color Floor Mounted European water closet with inbuilt low level PVC flushing cistern and Wash Basin for Physically Challenged Persons Toilet (Matrix) with necessary Grab Rails, hinged rails for support , pan connecter bend,checknut, stopcock etc., colour solid seat and cover with polythene buffer and flap, CP flanges, CP bolts and nuts, bracket with nuts and bolts wall flanges etc.,complete, Wash Basin shall include 15mm dia CP liver operated pillar Cock / auto closing pillar tap with waste coupling, 32mm dia CP bottle trap with extension pipe,supporting bracket with necessary steel to support basin 1 No.15mm CP angle valve with 450mm long CP connection pipe and CP wall flanges all of approved make etc., complete.

11

-

-

... More
INTERNAL SOIL AND WASTE PIPE SYSTEM:

-

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works).

-

-

-

... More
50 mm dia

350

-

-

... More
75 mm dia

750

-

-

... More
110 mm dia

375

-

-

... More
EXTERNAL SOIL AND WASTE PIPE SYSTEM:

-

-

-

... More
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works).

-

-

-

... More
75 mm dia

50

-

-

... More
110 mm dia

100

-

-

... More
160 mm dia

650

-

-

... More
200 mm dia

300

-

-

... More
Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) including dismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ).

-

-

-

... More
110 x 75 mm dia (20 mm water seal)

300

-

-

... More
Supplying & fixing in position PVC Urinal trap with antifoul arrangement of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) including dismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC urinal trap should be got approved by the Executive Engineer before use on works ).

-

-

-

... More
110 x 75 mm dia (20 mm water seal)

75

-

-

... More
Supplying & fixing in position 150 X 100 mm square mouth 'P' or 'S' trap stone ware Gully trap 'A' grade with cast iron double gratings of size 150 X 150 mm with C.I. air tight cover with frames of size 300 X 300 mm at bottom & top respectively with necessary earth work excavation, laid over a bed of brick jelly cement concrete 1:3:6, 150 mm thick using 20 mm size broken brick jelly including necessary brick work & plastering, &including dismantling masonry wherever necessary & redoing the damaged portions to the original condition & by using cement concrete 1:3:6 using 20 mm stone jelly for fixing the Gully trap & giving connections to the stone ware sewer line etc., complete, complying with standard specification. (The stone ware gully trap should be got approved by the Executive Engineer before use on works ).

40

-

-

... More
Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mix for base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floating coat of neat cement ,supplying and fixing SFRC manhole cover with farame of size 600x600 mm , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) (SOR)

-

-

-

... More
450x450mmx 450mm deep to 750mm deep

2

-

-

... More
600x600mmx 450mm deep to 1000mm deep

8

-

-

... More
900x 900mm x 1000mm deep to 1500mm deep

4

-

-

... More
1200x 1200mm x 1500mm deep to 2000mm deep

20

-

-

... More
INTERNAL WATER SUPPLY SYSTEM:

-

-

-

... More
Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. Internal & Vertical

-

-

-

... More
15 mm dia

240

-

-

... More
20 mm dia

200

-

-

... More
25 mm dia

400

-

-

... More
32 mm dia

38

-

-

... More
40 mm dia

290

-

-

... More
50 mm dia

125

-

-

... More
EXTERNAL WATER DISTRUBUTION:(TERRACE,SHAFT, EXTERNAL PIPE)

-

-

-

... More
Supplying, laying, jointing, testing & Commissioning of UPVC Schedule 80 pressure pipes as per ASTM D 1785 with Sch 80 Fittings as per specifications, jointing with hold tite / super tite & tefflon tape and complete with fittings such as sockets, unions, reducers long or short bends, elbows, nipples flanges,checknuts,etc. Pressure testing of piping and back filling of trench complete as required. The quoted rate shall include necessary earth works, fittings like Tees, Bends, Offsets etc., G.I. brackets with pvc coated GI clamps, nuts & bolts, anchor fasteners, grip bolts, GI threaded, rods, etc., complete for external pipes. (For under ground or above ground external water supply piping.) Vertical & External

-

-

-

... More
25 mm dia

50

-

-

... More
32 mm dia

75

-

-

... More
40 mm dia

120

-

-

... More
50 mm dia

375

-

-

... More
62 mm dia

300

-

-

... More
80 mm dia

150

-

-

... More
Supplying, installing, testing and commissioning of approved make full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tested to a pressure not less than 20 Kg / sqcm with threaded joints complete.

-

-

-

... More
20 mm dia

30

-

-

... More
25 mm dia

20

-

-

... More
32 mm dia

15

-

-

... More
40 mm dia

15

-

-

... More
50 mm dia

15

-

-

... More
Manufacturing, supply and delivery of resilient seated wafer type butterfly valve in accordance with EN 593, centric disk mounted in three maintenance-free bearing bushes, tight in both flow directions, Replaceable rubber sleeve with integrated seal for functionally reliable use for flared flanges, welding flanges, PE flanges as well as loose flanges with V-collar, Stable seat due to collar with vulcanized support ring. Vacuum tight upto 1 Torr. Face to face length acc.to 558-1, basic series 20(DIN 3202/k1). With Electrostatic epoxy powder coating (EP-P) inside and outside color blue RAL 5005 with minimum coating thickness of 250 microns. The EPDM rubber & Epoxy Powder should be approved by W 270.(EP-P it is resi-coat powder approved for drinking water application, applied through fusion bonding technology process by dipping the shot-blasted casted components heated up to 200 deg C) and with 5 yearswarranty

-

-

-

... More
62 mm nominal bore

10

-

-

... More
80 mm nominal bore

10

-

-

... More
Supplying and installing, in position of approved quality high pressure rated Gun Metal/Bronze Float operated ball Valve with rough body with plastic ball float and brass rods of required length suitable for test pressure of not less than 10 Kg/sqcm.

2

-

-

... More
Supplying &installing, Chrome plated forged brass body and cover Auto Air release valve for domestic and flushing water supply risers, suitable for pressure not less than 15 Kg/Sq.cm.

2

-

-

... More
Supplying and installing, in position of approved quality high pressure rated Gun Metal/Bronze Float operated ball Valve with rough body with plastic ball float and brass rods of required length suitable for test pressure of not less than 10 Kg/sqcm. Inside size 900 x 900mm and 1000 mm deep

2

-

-

... More
Supplying ,installation, testing and commissioning of approved make Electromagnetic water meter with totalizer including IBMS Interface and Y strainer, necessary unions for fixing on the inlet main as shown on the drawing etc complete with water meter chamber with cover and necessary Isolation valve, union etc., complete. 80 mm nominal bore

2

-

-

... More
PUMPS

-

-

-

... More
Supply ,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 9000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump)

6

-

-

... More
Supply ,erection and testing & commisioning of 2HP Monoblock pumpset in the capacity of max 3 bar Pressure pumps fitted with bronze impellers and having delivery size of 65 & 80 mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Terrace Booster Pump)

2

-

-

... More
Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.

-

-

-

... More
Upto 5 HP

8

-

-

... More
BORE WELLS

-

-

-

... More
Drilling of 12" dia vertical borewell so as to have a finished size of 6" dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractor's rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs.

-

-

-

... More
300mm

60

-

-

... More
150mm

140

-

-

... More
Reaming from 200mm dia pilot bore to 350mm dia bore as direct by the Engineer incharge up to 80mtr depth ending below ground level

200

-

-

... More
Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992

-

-

-

... More
200mm dia CS ( plain pipe)

24

-

-

... More
200mm dia RS

36

-

-

... More
150mm dia RS

140

-

-

... More
Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers.

-

-

-

... More
200mm dia CS

24

-

-

... More
200mm dia RS

36

-

-

... More
150mm dia RS

140

-

-

... More
Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock.

2

-

-

... More
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by 'V' notch method.

16

-

-

... More
Supply ,erection and testing & commisioning of 3HP submersible pumpset to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge.

2

-

-

... More
Supplying and fixing in position best quality of HDPE pipes with ISI mark of following dia with specials including cost and coveyance of HDPE pipes and specials, labour charges for erection of pipes in the borewell and jointing materials etc., all complete as directed by the departmental officers.

-

-

-

... More
50mm dia. HDPE Pipe

360

-

-

... More
RO WATER TREATMENT PLANT - CAPACITY - 15 CUM/DAY (SUPPLY AND INSTALLATION TESTING AND COMMISSIONING OF ELECTRO, MECHANICAL EQUIPMENTS AND PIPING WORKS)

-

-

-

... More
RO Feed Pump

-

-

-

... More
Providing, installing, testing and commissioning of Non clog Centrifugal Pump of suitable capacity with following specifications Capacity -1.50 m3/hr @ 30 m head Moc -SS Type - Mono Block

2

-

-

... More
Micron Filter

-

-

-

... More
Providing, installing, testing and commissioning of Micron Filter with following specifications Micron filter with cartridge- SS - Housing Capacity- 1500 lph

2

-

-

... More
High Pressure Pump with Motor

-

-

-

... More
Providing, installing, testing and commissioning of Non clog Vertical Centrifugal High pressure Pump of suitable capacity with following specifications Flow rate - 1500lts/hr Power Rating - 3 HP, 415 V, AC, 50 HZ Head - 120 mts

1

-

-

... More
SMBS/Acid & Antiscalent dosing system

-

-

-

... More
Providing, installing, testing and commissioning of Dosing system with following specifications Capacity of Dosing Pump - 4 LPH Dosing Tank - 50 Litres Moc -PP Make -Xeed/ /Focus/Miltonroy

2

-

-

... More
RO Membranes

-

-

-

... More
Providing, installing, testing and commissioning of RO Membrane with following specifications Membranes -4”dia x 40" long – Thin Film Composite Membranes Make -Hydranautics

2

-

-

... More
Membrane Housing

-

-

-

... More
Providing, installing, testing and commissioning of RO Membrane Housing with following specifications Moc -FRP Make -Advanced Composite /Pentair

1

-

-

... More
Panel Mounted Rota Meter

-

-

-

... More
Providing, installing, testing and commissioning of Panel Mounted Rota Meter with following specifications Range -200 – 2000 Lph Make- UKL / Eureka /Aster

2

-

-

... More
RO Skid

-

-

-

... More
Providing, installing, testing and commissioning of RO Skid with following specifications RO skid - MOC -Fabricated in MS Powdered Coated with required SS Piping & Valves Comprises of panel mounted Pressure Gauges - 0 – 5 kg / cm2 – 2 Nos & 0 -14 kg / cm2 – 1No and Pressure Switches -2no Make : - Fiebig / Waree

1

-

-

... More
Chemical Cleaning System

-

-

-

... More
Providing, installing, testing and commissioning of Chemical Cleaning system with following specifications Tank - 250 Litres Cleaning Pump - 1.0 m3 / hr Head - 30 mts Make - Grundfos / ITT

1

-

-

... More
RO reject tank-

-

-

-

... More
Supplying, fixing, testing and commissioning of HDPE (Sintax /Infra) water tank conforming IS12709-1996 including inlet out let, overflow and drain pipe arrangement with necessary valve and tank supporting pedestal etc ,complete. Capacity :2000 Liters Make : Sintex / Infra

1

-

-

... More
UV lamp

-

-

-

... More
Providing, installing, testing and commissioning of UV system with following specifications Capacity : 1.50 m3 / hr MOC : SS 304 UV Lamp Make : Phillips /Alfa/Crystal Aqua

1

-

-

... More
Automation of RO plant

-

-

-

... More
Semi Automation of the plant including, electrical operated valves, level controller and cabling

1

-

-

... More
RO Permeate Storage Tank

-

-

-

... More
Supplying, fixing, testing and commissioning of HDPE (Sintax /Infra) water tank conforming IS12709-1996 including inlet out let, overflow and drain pipe arrangement with necessary valve and tank supporting pedestal etc ,complete.

1

-

-

... More
Capacity :15000 Liters

-

-

-

... More
Intermediate Storage Tank

-

-

-

... More
Supplying, fixing, testing and commissioning of HDPE (Sintax /Infra) water tank conforming IS12709-1996 including inlet out let, overflow and drain pipe arrangement with necessary valve and tank supporting pedestal etc ,complete.

2

-

-

... More
Capacity : 2000 Liters Make : - Sintex / Infra

-

-

-

... More
Dual media filter

-

-

-

... More
Supply, installation, testing & commissioning of Dual media pressure filter as per design size, working pressure, flow rate and internal distribution systerm for filtration. Designed to operate on a suspended solids level as indicated in inlet water conditions earlier. The filter shall be fitted with inlet distribution and bottom collecting system. Complete set of valves and frontal pipe work etc,. complete

1

-

-

... More
Size 450mm Dia x 1650 mm HOS MOC : FRP with multiport valves Make :Standard

-

-

-

... More
Filter feed tank

-

-

-

... More
Supplying, fixing, testing and commissioning of HDPE (Sintax /Infra) water tank conforming IS12709-1996 including inlet out let, overflow and drain pipe arrangement with necessary valve and tank supporting pedestal etc ,complete.

1

-

-

... More
Capacity :4000 Liters Make : Sintex / Infra

-

-

-

... More
Filter Feed Pump

-

-

-

... More
Providing, installing, testing and commissioning of Non clog Centrifugal Pump (Horizontal foot mounted motor coupled with pump) of suitable capacity for Raw water transfer from UG sump to pressure sand filter and activated carbon filter with necessary accessories, such as ,foundation bolts, mounting assembly suction and discharge piping works, Include all accessories like valves, NRV, strainers etc complete.

2

-

-

... More
Capacity :1.50m3/hr @ 25 m head Moc : SS Type : Mono Block Make :Grundfos /ITT/Equ

-

-

-

... More
INTER CONNECTING PIPING

-

-

-

... More
Providing, installing, testing and commissioning of UPVC pipe 10 kg/cm2 pipe of required dia conforming to is including pipe specials like bend to required degree, elbow, tee, union, Cutting the pipes to requirement, making joints with pipe specials, Making earth work in excavation, refilling, supports, Conducting hydraulic test to a pressure of 6Kg/cm2, rectifying the leaks if any in laid pipe work, etc,

-

-

-

... More
Pipe Make: Finolex / Equivalent (UPVC)

-

-

-

... More
Inter Connecting Piping Material , Butterfly valves, NRV's, Pipe fittings , supports within the WTP

1

-

-

... More
ELECTRICAL AND INSTRUMENTATIONS

-

-

-

... More
Electrical starter with necessary cabling for RO WTP

-

-

-

... More
Electrical Starters :Electrical Starters with Necessary Cabling and accessories Make :Siemenns/L& T Components

-

-

-

... More
Control Panel

-

-

-

... More
Providing, installing, testing and commissioning of Control Panel : Fixed cubical type with weather proof DOL Starters consisting of incoming feeder with outgoing feeder feeders with additional 2nos spare feeder, Voltmeters, Ammeter, push button with indicator lamp, overload relays,Contactors,Bus bar of required size, control cablings etc. Inter connecting Electrical Materials such as control panel , cabels, cable gland supports etc

-

-

-

... More
Type of panel :compartment for individual feeder

-

-

-

... More
MOC :MS ( 1.6mm thick sheet )fabricated with powder coating

-

-

-

... More
cable entry : Bottom

-

-

-

... More
Cables : IS standard Copper armored cables

-

-

-

... More
Make : Omega / Finolex / Equivalent

-

-

-

... More
Size :3 Core x 2.5 Sq mm, 3 Core x 1.5 sq.mm, 3 Core x 4 sq.mm

-

-

-

... More
Earthings :Consist of Copper flats 25 x 3 mm Size 8 SWG copper wire for earthing motors ,MCC Etc.and required compression glands ,ferrules, ties, aluminum etc

1

-

-

... More
Instrumentation

-

-

-

... More
Instruments like hardness testing kit, Pressure gauge, level controllers and Paddle type digital flow meter at the inlet and out let. PH Meter at the final outlet like panel Mounted Systems.

1

-

-

... More
Electrical flowmeter for Domestic & RO outlet with RS485 provision Type - Electromagnetic Make- RLT/ E&H

2

-

-

... More
Testing equipment

-

-

-

... More
TDS / pH Meter :Online Make :HM – Digital /Aster

2

-

-

... More
FIRE PUMPS AND ACCESSORIES

-

-

-

... More
STANDBY DIESEL ENGINE PUMP

-

-

-

... More
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of following and complete in all respects as required. a. End suction, top discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg. / sq. cm at highest and farthest outlet at specified flow of 2280 LPM at 70m head conforming to IS 1520. b. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dyanamo, solenoid switches etc. c. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle, providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc. (Make: Kirloskar / Equivalent). d. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m, outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessory MS support arrangements from wall or ceiling as per site condition.

-

-

-

... More
e. Dash board consisting the instruments like temperature gauge, galvano type DC Ammeter, lubricant oil pressure gauge, ignition switch, emergency stop and all other protection equipment as per specification, stop seleneid for auto stop in the event of fault with audio indications, painted with post office red colour etc., as required. f. 12 V / 24 V storage battery, maintenance free tape, 180 AH rating, MS fabricated common base plate, coupling guard, foundation bolts etc., as required. g. Positioning the diesel engine driven fire pump over cement concrete foundation using suitable size anti-vibration mounting arrangement. All works carried out as per standard methods and as instructed by the manufacturer and as directed by the Departmental Officers.

1

-

-

... More
MAIN ELECTRICAL DRIVEN FIRE PUMPSET

-

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump Rated for 2280 LPM at 70 metres head with Electrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. The rate inclusive of necessary vibration, bad mounting etc., as per standard method as directed by the Deparmental Officers.

1

-

-

... More
JOCKEY PUMPSET

-

-

-

... More
Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges,etc., complete as per standard specification and as directed by the Departmental Officers.

1

-

-

... More
Supply, installation and commissioning of air vessel (size 250 mm Dia & 1500 mm height) for pressurization of hydrant system complete with adequate pressure switches (as per design / requirement) with valves to operate as per operating sequences including 25 mm Dia drain valve, air release valve with stop cock on the top, 25 mm Dia inlet with isolating valve duly painted from inside and outside with two coats of synthetic enamel paint over a coat of zinc rich primer complete as required. (Vessel should be suitable for rated working pressure).complete as per the technical specification

1

-

-

... More
Supplying, installation, testing and commissioning of Fire Fighting Electrical Control Panel ofcubical construction, floor mounted type fabricated using CRCA sheet, compartmentalised with hinged lockable door dust and vermin proof, cable alley, inter connection having switch gears and accessoriesmounting and internal wiring, earth terminals, numberings, necessary meteringprotectionsand indications complete inall respect suitable for operationon 415volt, 3phase, 50HzAC supply with enclosure protection class IP 54 and mounted with the followings. A. Common Panel in Fire Pump House (i). Incomer a. 1 No. 315A TP & N SDFU with HRC fuses b.1setof600A,4baraluminiumbusbar,415V,50HZAC supply c. 1 No. (0-500A) digital ammeter with selector switch & CTs d.1No. (0-500V)digital voltmeterwithselector switchand control fuses e. 3 Nos. phase indication lamp LED type with toggle switches with control fuses (ii). Outgoing

-

-

-

... More
a. Main Fire Pump 250 A TPN SDFU with HRC fuses with sutable HP fully automatic starter / delta starterwithover loadprotection, digital ammeter with built-in selector switch and suitable CTs, current sensing types ingle phasing preventer complete with all accessories and internal wiring required for automatic operation,selector switch for auto /manual /OFF operation 1 No.

-

-

-

... More
b. Jockey Pump 125 A TPN SDFUwith HRC fuses with suitable HP fully automatic starter / delta starter with over load protection, current sensing type single phasing preventer complete with all accessories and internal wiring required for automatic operation, selector switch for auto / manual operation - 1 No. c. Diesel Engine Control comprising of: 1. Auto /manual selector switch and 3 attempt starting device, timersandrelaysas required, pushbuttons, start / stop in manual mode. 2. Indication lamp for high/ low lubricant oil pressure, high water temperature and engine ON indication. 3.Batterycharger suitable for12V/24VDCwith boost and tickleselector switch, 0-15V/0-30VDCvoltmeter, 0-20A DC ammeter. 4.All standard relays and accessories for automatic operation of diesel engine.

1

-

-

... More
5. The above combined panel mounted over MS channel fabricated framewith cement concrete platform, all other connection works carriedout asper standard methods and including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
Supply and laying of following sizes of armoured Aluminium / Copper cables for electrical motor. control Panel, Pressure switch, jockey motor etc. all incidental charges necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc.

-

-

-

... More
3 cores 185sqmm armoured aluminium cable

30

-

-

... More
3 core 95 sq.mm. armoured aluminium cable

15

-

-

... More
3 core 10 sqmm armoured copper cable

15

-

-

... More
10 core 2.5 sqmm armoured copper cable

15

-

-

... More
2 core 2.5 sqmm armoured copper cable

40

-

-

... More
Earthing arrangements with GI earth plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work. Refilling the sides of foundation with excavated earth as per the standard specification and as directed by the department officers.

1

-

-

... More
Supply and run o f25 mm x 6 mm GI Flat Down Condutor with necessaryclamps /supports on wall / floor / ground for earth connection

30

-

-

... More
PIPES & FITTINGS

-

-

-

... More
Supply, erection, testing and commissioning of castiron body and bronze internal non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
250 NB

3

-

-

... More
150 NB

22

-

-

... More
100 NB

1

-

-

... More
80NB

1

-

-

... More
Supply, installation, testing and commissioning of Cast Iron Butterfly isolation valve (PN:16) as per specification with necessary flanges, GI nut, bolts & washers, painting, etc. Complete as per the technical specification .150 NB - Lever operated

30

-

-

... More
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
150 NB

4

-

-

... More
80NB

1

-

-

... More
Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc.,complete as per standard specification and as directed by the Departmental Officers.

15

-

-

... More
Supply and installation of 'Y' strainer (PN 16) with necessary flanges,GI bolts, nut, & washers, painting, etc. complete as required of the following diameters

-

-

-

... More
150NB

2

-

-

... More
100NB

1

-

-

... More
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
250NB - 8 mm thick

18

-

-

... More
200NB - 6.35 mm thick

6

-

-

... More
150 NB - 5.4 mm Thick

1586

-

-

... More
100 NB - 5.4 mm Thick

282

-

-

... More
80 NB

484

-

-

... More
65 NB

460

-

-

... More
50 NB

360

-

-

... More
40 NB

192

-

-

... More
32 NB

216

-

-

... More
25 NB

3500

-

-

... More
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers.

35

-

-

... More
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers.

70

-

-

... More
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

35

-

-

... More
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

17

-

-

... More
Supply and fixing in position of Fire Fighting Duct Window having proper glass window type double door with universe open key, painted inside white and outside post office red for the sizes of 1300 x 900 x 500mm (L x B x D) fabricated using 25 x 3mm MS 'L' Angle and all sides covered with 2mm thick MS sheets, suitable arrangements to kept 2 Nos. of Fire Fighting Hoses and 1 No. Branch Pipe, mounted in fire duct using anchor fasteners, etc., as per standard specifications and as per directed by the Departmental Officers.

18

-

-

... More
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers.

18

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

1

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting 2 Way Fire Brigade Inlet with necessary gun metal 63mm dia non-return spring shutter arrangements so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers.

1

-

-

... More
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anticorrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.

-

-

-

... More
150 NB

550

-

-

... More
80 NB

24

-

-

... More
Supply, fixing of 300 NB Hume Pipe with Class NP3 Type for Undereground Road Crossing areas with Collar .

30

-

-

... More
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental fficers.

16

-

-

... More
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

15

-

-

... More
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc.,completed as per standard specification and as directed by the Departmental Officers.

3

-

-

... More
Supply, Erection, Testing and Commissioning of Water Monitor with 63 mm bore Flanged connection to minimum flow rate of 1750 LPM as per IS 8442.

3

-

-

... More
FIRE AND DOMESTIC WATER TANKS

-

-

-

... More
Supply,Installation,testing and commissioning of GFS (Glass fused steel tank) of following sizes, Rate shall be inclusive of nozzles inlet,outlet,drain,overflow,testline,fire brigate&equilizer and vortex plate, manhole ,circumference railings and ladder to access manhole as per drawing,nuts,bolts& liners as per specifications.

-

-

-

... More
Fire Water Tank - 4.3 metre dia x 6.1 metre Height- Effective Capacity - 80 Cum

2

-

-

... More
SPRINKLER SYSTEM

-

-

-

... More
Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 / 79 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. K-Factor-80

1350

-

-

... More
Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Departmental Officers.

150

-

-

... More
Supply, Installing, testing and commissioning of Stainless Steel Corrugated Flexible Braided Pipe (Hose) for dropping sprinklers below false ceiling. Pipe shall be 16 bar pressure rating and 1500mm long, 25mm dia with union / reducer, collar, clamps, etc. It shall have UL listed and FM approved..

150

-

-

... More
Supplying & installing of FM approved make vane type flow switches (flow sensors) suitable to be fixed directly on line of the following diameters, with 1 NO & 1 NC potential free contacts (suitable provision for IBMS system)as per specification

-

-

-

... More
150NB

9

-

-

... More
Supply and installation of FM approved alarm check valve with full valve trim. The alarm check valve shall be equipped with a removable cover assembly. The alarm valve shall be listed for vertical position. T shall be equipped with gauge connections on the system side and supply side of the valve clapper. The alarm valve trim piping shall be externally galvanised. Maximum water working pressure to 250 PSI. This shall be inclusive of hydraulic powered water motor alarm by way of integral valve alarm line trim piping. Water motor gong shall be connected to a water pressure retarding chamber to limit the propensity of unnecessary alarms. Water motor alarm shall be equipped with a rear closure plate to limit the access of foreign materials of accumulation of debris as per specification

-

-

-

... More
150mm

3

-

-

... More
PORTABLE FIRE EXTINGUISHERS:

-

-

-

... More
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.

80

-

-

... More
Supply and fixing of Carbon-di-Oxide Gas Type 4.5 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers.

80

-

-

... More
Supply and fixing of Mechanical foam type fire extinguishers of 9 lit capacity with fixing hangers, hose, brackets, screws to required size etc., complete as per IS:15683

2

-

-

... More
Supply and kept in position of Trolley Mounted Water CO2 Stored Pressure Type 50 litres capacity Fire Extinguisher as per IS13385, complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, mounting trolley with moving wheel, safety clip, etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

1

-

-

... More
Supply and kept in position of Trolley Mounted Type 22.5 kg. Carbon-di-Oxide Fire Extinguisher as per IS15683, complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, mounting trolley with moving wheel, safety clip, etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

1

-

-

... More
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers

6

-

-

... More
HVAC

-

-

-

... More
CHILLER

-

-

-

... More
Design, Supply, delivery, hoisting, including the customs clearance, freight up to site, Insurance, for the following items as shown on the equipment data and drawing for complete and satisfactory operation. Specification to be complied by the vendor to meet the performance of chiller as per tender conditions. All necessary hardware's / software's to integrate the chiller panel to BMS system shall be provided free of cost by chiller manufacturer / supplier. Control panel should be with open protocol like Modbus RTU/ Bacnet/ Lon work for integrating with BMS. Receiving the above imported equipment at site, including port charges, port handling charges, other local duties, loading, transportation/insurance up to site and all other taxes and incidentals complete till delivered at site, unloading, delivery at site, etc of the below equipment's. chiller tolerance will be 1.5 % max from the rated capacity and the reduced capacity shall be increased to other chiller ( Air or water cooled) to meet the requirement. The chiller Microprocessor shall be suitable for CPM / BMS integration and provided with Bacnet protocal. Chiller is accepted only based on 100% loading and its performance shall be tested at site against approved data sheet. Any fall back on the performance to be corrected and rechecked and then chiller will be accepted.

-

-

-

... More
Air cooled chiller - Fixed speed

-

-

-

... More
Supply Installation, testing and commissioning of AHRI certified, BMS compatible AIR COOLED SCREW CHILLERS WITH close transition wye delta starter with single/multiple screw compressors, with individual circuit, air cooled condenser, insulated chiller, flow switch at chiller, spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled water inlets & outlets, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC R134a as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for CPM / BMS integration and provided with suitable protocal.

-

-

-

... More
Air cooled chiller - Fixed speed

-

-

-

... More
Chiller Capacity : 180TR at Design Condition

2

-

-

... More
Chiller Performance: 1.20 kW/TR FL (COP shall be min 3.10) and 0.74 kW/TR IPLV at AHRI condition

-

-

-

... More
Evaporator Side: Water in & out : 11.5 Deg C & 6.5 Deg C Fouling factor : 0.0001 hr.sqft.degF/BTU

-

-

-

... More
Condenser Side: Design Ambient 42 degC

-

-

-

... More
Sound pressure at 100% load : 72- 74 Dba @ 10 mts distance

-

-

-

... More
Air cooled chiller - VFD

-

-

-

... More
Supply Installation, testing and commissioning of AHRI certified, BMS compatible AIR COOLED SCREW CHILLERS WITH VFD starter with single/multiple screw compressors, with individual circuit, air cooled condenser, insulated chiller, flow switch at chiller, spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled water inlets & outlets, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC R134a as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for CPM / BMS integration and provided with suitable protocal.

-

-

-

... More
Air cooled chiller - VFD

-

-

-

... More
Chiller Capacity : 180TR at Design Condition

1

-

-

... More
Chiller Performance: 1.20 kW/TR FL ( COP shall be min 3.10) and 0.65 kW/TR IPLV at AHRI condition

-

-

-

... More
Evaporator Side: Water in & out : 11.5 Deg C & 6.5 Deg C Fouling factor : 0.0001 hr.sqft.degF/BTU

-

-

-

... More
Condenser Side: Design Ambient 37 degC

-

-

-

... More
Sound pressure at 100% load : 72- 74 Dba @ 10 mts distance

-

-

-

... More
CENTRIFUGAL PUMPS

-

-

-

... More
Supply,installation,testing & commissioning of End Suction top discharge/ Centrifugal water pump complete with Horizontal mounting type motor, Couplings, Coupling guard, High tensile steel shaft, Bronze / SS impeller, Stuffing box with Mechanical seal,inertia block, Bronze shaft sleeves and wearing rings, Ball bearings, Foundation bolts, Nuts, Supports and Corrosion-resistant finish etc. & all necessary accessories as per relevant std. The pump motor shall be suitable for 415+/- 10% volts, 50 cycles, 3 phase AC power supply. motor shall be IE3 mounted and IP 55 rated & suitable for outdoor installation. The commissioning of the system to be executed by Manafacturer's authorized representative. Pump should be externally insulated with thermal insulation of 38mm thick Nitrile rubber , 24 gauge aluminum cladding and necessary supports for the pumps. The pump efficiency shall not be less than 80%.All pumps must comply with Tender Specification as provided separately. Head and Flow Rate : The Indicated Flow rate and Head is only provisional. contractor to select pump to match with chiller flow rate and required system head based on the finalized equipment / items. Head calculation and selection to be submitted to consultant for review / approval. The procurement shall be processed only after duly verification / approval of calculation and selection from the consultants.

-

-

-

... More
PRIMARY VARIABLE PUMP

-

-

-

... More
Flow Rate & Head : 480 USGPM, 25m

3

-

-

... More
Indicative motor rating : 12.5 kW

-

-

-

... More
Logic Control Panel: Supply, installation & commissioning of Powder coated Sheet Steel with IP 55 double enclosure suitable for Outdoor installation complete with VFD for all Pumpsets. The Panel also should have star-delta by pass starter arrangement to operate the pumpset during the failure of VFD. VFDs (Ambient temp 50 Deg without deration), 100kA SC rating with built in harmonic reduction technology to limit THDi5% @ 100% load & 75% load with input PF0.99 even @50% load as per IEC 61800-2(Valid third party test report shall be provided). The panel for housing the VFD should be supplied by the same OEM only Hardware / Software for BMS Transmission (All Parameters) in form of Modbus / Backnet protocol - 1 lot. 2 Sets of Dp Sensors for each pump set. loading, transportation/insurance up to site, octroi charges if applicable etc., complete till delivered at site. The commissioning of the system to be executed by Manufacturer's authorized representative.

1

-

-

... More
Supply,installation,testing & commissioning of DPT across the chiller for the operation of modulation valve and all accessories,as required

3

-

-

... More
Supply,laying and commissioning of 3 C X 1.5 sqmm screened communication cable for pump variable operation

300

-

-

... More
PIPES & VALVES

-

-

-

... More
CHILLED WATER PIPING: Supply & erection of the following factory rolled MS 'Heavy' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all welded joints

-

-

-

... More
The quoted rates under pipes section shall inclusive of all necessary fittings like bends, elbows, Tee, etc. and inclusive of making hole in the wall, chasing, chipping, pipe sleeve of suitable higher size, makings provisions for BAS field devices/sensors, Pipe support accessories like clamps, anchor fasteners, tie rods, brackets, nuts and bolts, etc. as shall also be included in the quoted rate.

-

-

-

... More
Supply, erection, testing and commissioning of factory rolled ERW MS pipes Heavy class confirming to IS:1239 upto 150NB and IS:3589 for 150NB & above pipe sizes for Chilled water

-

-

-

... More
250 NB - 6.3 mm wall thickness.

90

-

-

... More
200 NB - 6.3 mm wall thickness.

90

-

-

... More
150 NB

152

-

-

... More
125 NB

54

-

-

... More
100 NB

260

-

-

... More
80 NB

70

-

-

... More
65 NB

198

-

-

... More
50 NB

12

-

-

... More
40 NB

6

-

-

... More
32 NB

6

-

-

... More
25 NB

75

-

-

... More
PIPE INSULATION: Supply, installation and testing of following mentioned thick Nitrile rubber Insulation - FM Approved with glass cloth of 50 GSM as a vapor barrier and 26g aluminum cladding over the cloth to be provided for all chilled water pipes and fittings like valves, flanges and unions, etc. as per the approved shop drawings & specifications

-

-

-

... More
Thickness of the insulation are as follows. (Tube to be used upto 65mm dia) upto 40mm dia - 25mm thick , 50mm to 125 mm dia - 38mm thick 150 mm dia- 250mm - 45mm thick 250mm above - 45mm

-

-

-

... More
All valves shall be insulated by similar thickness of the pipe specifications.

-

-

-

... More
250 NB

98

-

-

... More
200 NB

110

-

-

... More
150 NB

168

-

-

... More
125 NB

60

-

-

... More
100 NB

288

-

-

... More
80 NB

78

-

-

... More
65 NB

226

-

-

... More
50 NB

15

-

-

... More
40 NB

3

-

-

... More
32 NB

3

-

-

... More
25 NB

80

-

-

... More
Supply, installation, testing & commissioning of Extended stem Butterfly valves with flanges - PN 16 with cast iron body, SS disc – NYLON Impregnated with Nylone Coated, SS-410Stem ,EPDM integrally Moulded Liner with Hand lever, suitable for mounting between pipeline flanges, suitable thickness of PUF insulation with 26g Aluminum cladding of fittings like valves, flanges and unions, additional supports, fixing accessories etc. of chilled water system as per the approved shop drawings & specifications. The valve shall be gear operated for 200NB and above.

-

-

-

... More
250 NB - Gear driven

5

-

-

... More
150 NB -Lever operated

15

-

-

... More
100 NB - Lever operated

12

-

-

... More
80 NB - Lever operated

8

-

-

... More
65 NB - Lever operated

16

-

-

... More
50 NB - Lever operated

1

-

-

... More
Supply,installation,testing & commissioning of two Way Motorised modulating Bypass valve with all accessories sized for Minimum flow of one chiller as per the specification. Pressure ating of the valve shall be PN16

-

-

-

... More
150 mm dia

1

-

-

... More
Supply, Installation and commissioning of Suction Guide made up of Cast iron body and removable SS-316 screen with 3mm perforations and a permanent magnet. Rate shall inclusive of end flanges/matching flanges, additional supports, fixing accessories, thermal insulation, etc. Pressure ating of the valve shall be PN16

-

-

-

... More
150 mm dia

3

-

-

... More
Supply,installation,testing & commissioning of Dual plate Check valves as per specification complete with matching flanges, additional supports, fixing accessories, thermal insulation, etc. Pressure ating of the valve shall be PN16

-

-

-

... More
150 mm dia

3

-

-

... More
Supply, installation, testing and commissioning of Balancing Valve (Globe Type) shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc. Pressure ating of the valve shall be PN16

-

-

-

... More
150 mm dia

3

-

-

... More
Supply,installation,testing & commissioning of ‘Y’ type strainer with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of matching flanges, additional supports, fixing accessories, thermal insulation, etc. Pressure ating of the valve shall be PN16

-

-

-

... More
80 mm dia

4

-

-

... More
65mm dia

8

-

-

... More
SITC of Flow Control Valve - Pressure independent type with Dynamic Balancing Cum 2 Way modulating valves for AHUs with actuator in a single Unit of Valve provided with spring return function. The valve shall be suitable for standalone operation. Valve shall be of PN16 Rating. The BMS compatible actuator shall be supplied by the valve manufacturer and capable of accepting 2-10VDC / 4- 20 mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications. Rate shall be inclusive of stepdown transformer, digital thermostat with inbulit and extenal temprature sensor, end flanges/matching flanges, additional supports, fixing accessories, dismantling the existing valves, thermal insulation with aluminium cladding, etc

-

-

-

... More
80 mm dia

4

-

-

... More
65 mm dia

8

-

-

... More
Supply, installation, testing & commissioning of approved make Bronze Ball Valve with 26g Aluminium cladding of fittings like valves, flanges and unions, etc. as per the approved shop drawings & specifications. thermal insulation, etc.

-

-

-

... More
25 mm dia

48

-

-

... More
Pressurization system

-

-

-

... More
Supply, Installation, testing and commissioning of Pressure maintaining station which consists of : i)Skid mounted Pressure maintaining station to maintain system pressure within +/- 0.5 bar of design pressure. Unit shall be complete with two pressurisation pumps (1W+1S), pressurisation tank and unpressurised tank. Unit shall also be able to de-aerate the chilled water. Unit shall be complete with microprecessor panel for auto-control and accessories like pressure transmitter, valves and interconecting piping. It will be insulated with 50mm thick as per specification and cladded with 26g Aluminum sheet. The Pressure rating shall be as per system design pressure.ii) 1000 lts capacity Pressurisation unit comprising of two multistage high pressure pumps (1 working +1 standby) with control logic panel with soft starters, valves, flow meter and other accessories as described in detailed specifications. The pumps shall be able to deliver at least 2 CMH flow at suitable pressure head. The unit shall be housed in powder painted canopy suitable for external installation.

1

-

-

... More
Supply, installation testing & commissioning of flow switch suitable for BMS compatible and all accessories, as required.

3

-

-

... More
Supply and erection of SS Glycerine filled Dial type Thermometers with range suitable for the temperature services. All SS Temperature Gauge, Dial Aluminum Black Graduation on white backround, Gasket-Neoprene, Case & Ring-AISI SS304 Bayonet Type, Bourdon & Socket SS 316,Accuracy +/_1% F.S, Ambient Temperature-25 deg C to 65 deg C, Operating Pressure 15 kg/cm square, Protection IP 55,65,66,. It should be installed in the thermo wells as explained in the tender specifications + with nitrile rubber insulation, as per the approved shop drawings & specifications

36

-

-

... More
Supply and erection of Dial type Pressure gauges, shall be of Bourdon (150 mm) type with range selected so that normal operation is near to middle of the scale. Bourdon Tube All SS Pressure Gauge, Dial Aluminum Black Graduation on white backround, Gasket-Neoprene, Case & Ring-AISI SS304 Bayonet Type, Bourdon & Socket SS 316,Accuracy +/_1% F.S, Ambient Temperature-25 deg C to 65 deg C, Process Temperature Max 100 deg C, Protection IP 55,65,66,( Range 0 to 7Kg, 10kg,). Siphons and cocks to be provided along with SS snubber. The price should include the cost of gate valve which is as shown in the tender drawing of suitable size with nitrile rubber insulation etc. as per the approved shop drawings & specifications

36

-

-

... More
Supply, installation, testing & commissioning of Automatic Air Vents with Ball valve and all accessories . Valve shall be installed at all high sections of piping as well as in the AHU room piping

11

-

-

... More
Supply and Installation of MS flat / angles / channels supports of various sizes including cutting, welding, grinding, fixing accessories and one coat of primer & two coats of enamel paints, minor civil works like grouting existing floors and walls etc. as required.

180

-

-

... More
Supply& installation of UPVC clad for thermal insulation with VOC adhesives over the duct /CHW whereever exposed

500

-

-

... More
AIR HANDLING UNITS

-

-

-

... More
Note: The AHU design shall be suitable for capacity variation of ± 5 % from the specified capacities. Such variation in capacities shall be operated in the same AHU BOQ description item for the billing purpose if the requirement calls for during execution stage. OEM to demonstrate performance parameters in factory for Airflow / Static / Power Consumption / Sound as shown in the technical submittals OEM to submit all major item test certificates like fans / motors / coils

-

-

-

... More
Air Handling Units

-

-

-

... More
Supply, installation, testing and commissioning of EUROVENT certified double skin construction draw thru type AIR HANDLING UNITS WITH PLUG FAN with Thermal Break Profile, with 40 mm panel thickness with 40 -45 Kg/m3 glass wool/rockwool/Puff density with 0.63 mm thick sheet as per specification, each complete with filter section MERV 8 7 MERV-13, min 6 Row Deep water coil for floor mounted AHU of copper tube & aluminium fins construction & electrical heater (where reheat is specified), with plug Fans as described below and vibration isolators. Coil size shall be selected for a maximum face velocity of 500 feet/minute and static pressure shall be as indicated. Motor shall be suitable for 415±10% volts, 50 cycles, 3 phase AC supply. Fan motor assembly (as whole) shall be statically and dynamically balanced to grade G 6.3 as per DIN/ISO-1940/AMCA 204-3/Eurovent.All units shall be complete with opposed blade Al.volume control dampers at outlet, return and fresh air connections. AHU & components should be designed & suitable for 110 % rated capacity for coil & fan etc..

-

-

-

... More
Plug fan section shall be equipped with a Single Inlet Centrifugal Impeller with High Efficiency Backward curved blades and external rotor and plug fan motor, energy optimized for operation without spiral housing for high efficiency and favourable acoustic behaviour. Multiple Fans to be selected for Airflow greater than 8000 CFM for better redundancy & performance. The fan shall be selected in multiple sets so that combined sound pressure level shall not exceed 65 dBA at 1.5 meter distance.

-

-

-

... More
The minimum efficiency class of the motor shall be equivalent  to IE3. The motor shall be Permanent magnet external rotor motor with integrated electronics and suitable for continuous operation. The speed of the motor shall be varied through BMS. The fan in totality shall be of most efficient type so that the power Consumption and noise level is minimal. The motor shall be minimum IP54 protection class.

-

-

-

... More
control Panel for cooling coil in AHUas per specification

-

-

-

... More
Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Contractor to calculate static pressure based on final approved construction drawing and pressure drop of finalized Equipment / Items and submit for review / approval to the consultants. The procurement shall be processed only after duly verification / approval of calculation and selection from the consultants.

-

-

-

... More
Floor Mounted AHU

-

-

-

... More
Cooling Capacity: 40 TR & Flow rate - 15150 cfm, External Static Pressure :40 mm

2

-

-

... More
Cooling Capacity: 40 TR & Flow rate - 14900 cfm, External Static Pressure :40 mm

2

-

-

... More
Cooling Capacity: 34 TR & Flow rate - 13350 cfm, External Static Pressure :40 mm

2

-

-

... More
Cooling Capacity: 32 TR & Flow rate - 12000 cfm, External Static Pressure :40 mm

2

-

-

... More
Cooling Capacity: 30 TR & Flow rate - 11500cfm, External Static Pressure :40 mm

2

-

-

... More
Cooling Capacity: 30 TR & Flow rate - 10050cfm, External Static Pressure :40 mm

2

-

-

... More
supply,installation,testing and commissioning of Germicidal/ UV lamp with complete accessories.- For Each AHU - 1 No

12

-

-

... More
TREATED FRESH AIR UNIT WITH ENTHALPY RECOVERY WHEEL

-

-

-

... More
Variable Frequency Drive (VFD)

-

-

-

... More
Electrical starter panel complete with Variable frequency drives, Metering, all accessories, controls, harmonic filters for AHU drive motors including enclosure & necessary a/m switches and auxiliary contacts for BMS Operation of the following AHU Capacities. The final rating of the equipment kW shall be as per the approved MAR.

-

-

-

... More
Note : VFD shall be able to connect with BMS of any make, shall take ON/OFF command from remote controller, shall be able to do the following :- 1) scheduling from remote controller. 2) Accept signal from temperature/ pressure transmitter 3) Read V, A, Kwh, frequency & RPM & send to remote controller.

-

-

-

... More
All starter panels shall be BMS compatible with remote-Local.

-

-

-

... More
2.7 KW for TFA

6

-

-

... More
5.5 KW for AHU's

12

-

-

... More
7.5 KW

1

-

-

... More
12.5 KW

1

-

-

... More
VENTILATION SYSTEM

-

-

-

... More
Double skin Ventilation Fan Units

-

-

-

... More
Design, Supply, installation, testing and commissioning of Eurovent certified double skin Ventilation Fan Units suitable for outdoor application. The unit shall be of 40±2mm thick panel with PUF insulation density of 40kg/cm2, MERV 8filter section for Fresh air fans, DIDW/plug fan, High efficiency motor, spring vibration isolator for fan and motor, factory assembled volume control damper, Fire retardant canvass connections, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 415±10% volts, 50Hz, 3 phase AC supply & high efficiency (EFF-1). The fan external static pressure shall be 30mm. All Fresh air unit shall be suitable for outdoor installation with filter arrangements

-

-

-

... More
Air flow rate : 3000CFM

6

-

-

... More
External Static Pressure : 250 Pa

-

-

-

... More
Indicative Minimum Motor : 2.2 KW

-

-

-

... More
Served Area - Toilet Fresh air fan (Outdoor type)

-

-

-

... More
Cabinet type ducted-in-line ventilation fans (Ex. air)

-

-

-

... More
Supply, installation, testing and commissioning of Cabinet type ducted-in-line Exhaust air fans consists of GSS rectangular cabinet, removable access door for easy accessibility to motor and fan, flanged inlet and outlet for easy duct work connection, thermally protected motor and necessary supports and suitable power cable. The Air flow rate, External static pressure as follows. The fan shall be located as per tender drawing. (Weather proof for outdoor type fans and no weather proof for indoor type fans) All the motors shall be energy efficient.(EFF-1).

-

-

-

... More
Air flow rate : 4350 CFM

4

-

-

... More
External Static Pressure : 200 pa

-

-

-

... More
Indicative Minimum Motor : 3.15 KW, 4 pole, 3 Phase, (Outdoor type)

-

-

-

... More
Air flow rate : 4050 CFM

2

-

-

... More
External Static Pressure : 200 pa

-

-

-

... More
Indicative Minimum Motor : 3.15 KW, 4 pole, 3 Phase, (Outdoor type)

-

-

-

... More
PROPELLER TYPE FAN

-

-

-

... More
Supply, installation, testing and commissioning of propeller type direct drive fan, heavy duty wall mounted type complete with gravity louvers, motors, mounting brackets,, 5A plug top and required cables from nearby power socket, 600x600x20mm thick marine plywood with hole to suit impeller dia, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50Hz, 1 Phase AC supply.

-

-

-

... More
Air flow rate : 150 CFM

2

-

-

... More
Minimum dia Of the fan : 450mm

-

-

-

... More
Indicative Fan Motor : 0.22 KW,1 Phase

-

-

-

... More
Rectangular ducted-in-line / centrifugal exhaust fan

-

-

-

... More
Supply, installation, testing and commissioning of Rectangular ducted-in-line / centrifugal exhaust fan direct drive ventilation fans consists of GSS rectangular cabinet, removable access door for easy accessibility to motor and fan, flanged inlet and outlet for easy duct work connection, thermally protected motor and necessary supports and suitable power cable. The Air flow rate, External static pressure as follows. The fan shall be located as per tender drawing. (Weather proof for outdoor type fans and no weather proof for indoor type fans) All fresh air fans shall be supplied with Filter. All the motors shall be energy efficient.(EFF-1). External Static Pressure : 150 Pa

-

-

-

... More
1350CFM

6

-

-

... More
1450CFM

12

-

-

... More
SMOK EXHAUST AXIAL FAN

-

-

-

... More
EXHAUST AIR FAN (AXIAL FLOW FAN) : Supply, installation, testing & commissioning of Direct driven Smoke Spill Axial flow fan with galvanized steel Double flanged long casing, impellers of pressure casted aluminium adjustable pitch blades (Hub and Aero foil blades). The fan shell TEFC type with Class-F insulated motor, min IP 54 protection with direct driven motor. The price shall include the cost of suitable electrical starter panel. Motor shall be suitable for 415±10% Volts, 50 Hz, 3 phase AC supply. Each fan shall include all accessories, controls, Flexible connection, vibration isolators, etc., Please refer technical specifications for complete details and scope & quote accordingly.

-

-

-

... More
18300 cfm, 40mm of WC Static pressure

2

-

-

... More
22750 cfm, 40mm of WC Static pressure

4

-

-

... More
AXIAL FAN FOR PRESSURIZATION SYSTEM

-

-

-

... More
Supply, installation, testing & commissioning of Direct driven Smoke Spill Axial flow fan with galvanized steel Double flanged long casing, impellers of pressure casted aluminium adjustable pitch blades (Hub and Aero foil blades). The entire assembly of fan shall be suitable to operate at fire mode condition to withstand the temperature of 250 deg C for Two hours & with totally enclosed Class-H insulated motor, min IP 54 protection with direct driven motor. Motor shall be suitable for 415±10% Volts, 50 Hz, 3 phase AC supply. All the fresh air fans should have filter. Each fan shall include all accessories, controls, Flexible connection, vibration isolators as given below: Please refer technical specifications for complete details and scope & quote accordingly.

-

-

-

... More
Air flow rate : 8300CFM Axial Fan

2

-

-

... More
External Static Pressure : 300 Pa

-

-

-

... More
Indicative Minimum Motor : 3.6 KW

-

-

-

... More
Served Area - Lift well pressurization fan (Outdoor type)

-

-

-

... More
Air flow rate : 10300CFM Axial Fan

6

-

-

... More
External Static Pressure : 300 Pa

-

-

-

... More
Indicative Minimum Motor : 3.6 KW

-

-

-

... More
Served Area - Staircase pressurization fan (Outdoor type)

-

-

-

... More
Air flow rate : 16000CFM Axial Fan

2

-

-

... More
External Static Pressure : 300 Pa

-

-

-

... More
Indicative Minimum Motor : 4.4 KW

-

-

-

... More
Served Area - Lift well pressurization fan (Outdoor type)

-

-

-

... More
HVLS FANS: Supply, installation, testing and commissioning of AMCA certified High Volume Low Velocity (HVLS) fans of following size. The fans shall have three or more than three blades and blade shall be made up of aluminium. The fan motor shall be suitable for 413V, 3 Phase, 50 Hz AC supply. The motor rating shall be 1-2HP. The fan shall have VFD controller. The Rate shall be inclusive of Electrical panel, required length of power cable, Zone controller for controlling four fans with touch screen technology, control box, communication cable (CAD5 or CAD6), etc. The control shall have minimum features of fan speed control, scheduling, fan status, BMS integration, etc. The rate shall be inclusive for steel supporting arrangements for the fans

-

-

-

... More
IAMETER-16FT,MOTOR RATING-1.5 HP 3PHASE, STATIC WEIGHT-110KG

4

-

-

... More
IAMETER-14FT,MOTOR RATING-1.5 HP 3PHASE, STATIC WEIGHT-110KG

2

-

-

... More
AIR DISTRIBUTION SYSTEM

-

-

-

... More
(SHEET METAL WORKS)

-

-

-

... More
Supply, installation, testing and balancing of Air Distribution System consists of factory fabricated sheet metal ducting complete with supports (anchor fasteners and tie-rods, cradles, angle iron supports, GI bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, zinc chromate painted angle iron flanges, chipping and plastering of openings made for duct supports etc., complete as per specification. The rates quoted shall include turning vanes, straightening vanes, splitters, inspection doors probe, inlets with test openings enclosures complete with locking caps, chain, gaskets, wire ropes etc.

-

-

-

... More
1.2 mm thick GSS ducting (18G) – factory fabricated

50

-

-

... More
1.0 mm thick GSS ducting (20G) – factory fabricated

473

-

-

... More
0.8mm thick GSS ducting (22G) – factory fabricated

1426

-

-

... More
0.63mm thick GSS ducting (24G) – factory fabricated

3044

-

-

... More
DOUBLE SKIN PLENUM BOX

-

-

-

... More
Supply and installation of factory fabricated Double skin plenum box with inner sheet thickness shall be 0.8 mm plain GI sheet and outdoor thickness shall be 0.8mm pre coated sheet and 40mm thick sandwiched PUF insulation of density Not less than 40 kg/cm2 and necessary high grade extruded aluminium cross supports for rigidity and flanges in the plenum for duct cut outs and AHU connections. as per specification

88

-

-

... More
DUCT ACOUSTIC INSULATION

-

-

-

... More
Supply and installing of Acoustic insulation, Material shall be FM approved Nitrile Rubber foam. The material should be fibre free. The density of the same shall be within 140-180 Kg/m3.The material should have a thermal conductivity Not exceeding 0.038 W/mK. The maximum surface temperature the material should withstand is 105º C and minimum temperature should be -20ºC. The Thickness of the material shall be 15mm. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7.As per specification.

720

-

-

... More
DUCT THERMAL INSULATION

-

-

-

... More
Supply and installation Thermal insulation on ducts with Class 'O' Closed Cell Elastomeric Nitrile Rubber/XLPE with density of 40 - 60 kg/cum as per the thickness mentioned below, with fire retardant adhesive and joints sealed with 3mm thick, 50mm wide nitrile rubber self adhesive tape in accordance with the approved shop drawings and technical specifications. Quoted price shall be inclusive of adhesive, tapes, etc.

-

-

-

... More
9mm thick

3338

-

-

... More
UNDERDECK INSULATION

-

-

-

... More
Supply and fixing of Under deck insulation with make it as XLPE insulation - 25 mm thick with density of 40 - 60 kg/cum as per the thickness mentioned fixed to the soffit with the help of plastic expansion fasteners.  The plastic expansion fasteners is coupled with plastic wheel to support Polyurethane slabs.  The fasteners are fixed at an interval of 500 C/C

3154

-

-

... More
WALL ACOUSTIC INSULATION

-

-

-

... More
Supply and erection of pre fabricated wall acoustic Insulation for AHU Room with 50mm thick & 48kg/cm2 density glass wool with GI frame grid and covered with22 G perforated GI sheet with all accessories and supports. Etc

1392

-

-

... More
G.I VOLUME DAMPER (RECTANGULAR /ROUND)

-

-

-

... More
Supply and installation of GI volume control damper low leakage( handle type ) made out of 1.6mm thick galvanised sheet steel frame and opposed blades of 1.6mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system.as per specification

46

-

-

... More
MFD (MOTORAISED FIRE DAMPER)

-

-

-

... More
Supply and fixing of UL certified with labelled 16SWG G.I. Fire damper & Motorized (ON / OFF type ) actuators with sleeves. . These dampers will have 90 Minutes fire rating as per specification.

15

-

-

... More
16 G GI Damper Smoke & Fire Dampers. (MSFD)

-

-

-

... More
NON RETURN DAMPER

-

-

-

... More
Supply, installation, testing and balancing of GI Non return damper (low leakage) made out of 1.6mm thick galvanised sheet steel frame and blades of 1.0mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system. as per specification

3

-

-

... More
FRESH/EX.AIR STORM PROOF LOUVERS

-

-

-

... More
Supply, fixing, testing and balancing of Aluminium powder coated Fresh air and exhaust arrangement with storm proof louvers, volume control damper, MS weld mesh bird screen / mounting frame - 100mm louver spacing and 45 deg angle suitable for protection against splashing rain water fixed within a right aluminium frame as per specification.

6

-

-

... More
SA/RA AIR GRILLES

-

-

-

... More
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Supply & Return air. As per specification

58

-

-

... More
EX.AIR GRILLES

-

-

-

... More
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Exhaust air. As per specification

15

-

-

... More
DOOR TRANSFER GRILLE

-

-

-

... More
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated Door Transfer Grille with necessary flanges for Fresh air. As per specification

3.2

-

-

... More
COLLAR DAMPERS

-

-

-

... More
Supply, installation testing & balancing of collar damper shall be constructed out of extruded aluminium alloy with multiple blade of oppose blade type. The damper to be powder coated with mat finish black colour. The damper shall be used for the Supply air diffuser & grilles as per the drawings & specifications.

45

-

-

... More
HI-FLOW JET DIFFUSERS/NOZZLES

-

-

-

... More
Supply and installation of Hi-flow jet diffusers/Nozzles ( dia of the circular or same size square mounted in the above panel) with double banks of deflection louvers (wide extruded air foil blade design) which are individually adjustable to allow jet adjustments potential in two planes for spread or deflection to be set within 45 degree of the duct access and suitable for long throw air.

-

-

-

... More
315 mm dia

3

-

-

... More
400 mm dia

3

-

-

... More
SUPPLY AIR SQAURE DIFFUSER

-

-

-

... More
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Supply Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.

-

-

-

... More
475 x 475 mm neck size

3

-

-

... More
300 x 300mm neck size

3

-

-

... More
RETURN AIR SQAURE DIFFUSER

-

-

-

... More
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Return Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.

6

-

-

... More
SUPPLY AIR CIRCUALR DIFFUSER

-

-

-

... More
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Supply Air circular Diffusers shall be of removable core type (without collar damper) With Outer size: 300x300mm.

3

-

-

... More
RETURN AIR CIRCUALR DIFFUSER

-

-

-

... More
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Return Air circular Diffusers shall be of removable core type (without collar damper) With Outer size: 300x300mm.

3

-

-

... More
SPILL AIR BOXES

-

-

-

... More
Supply, installation testing & commissioning of spill air boxes made out of 0.8mm thick GI sheet with necessary spigot connection for fixing flexible duct and suitable collar for connecting to various neck diffuser / Grille / slot diffuser. The box should be internally insulated with 12mm thick open cell nitrile rubber. The plenum box shall be supported at the four corners with adjustable hanger / chain support.

-

-

-

... More
450 x 450 - 450mm height

3

-

-

... More
375 x 375 - 450mm height

3

-

-

... More
DUCT STATIC PRESSURE SENSOR

-

-

-

... More
Supply, installation, testing and commissioning of Duct Static Pressure sensor with accessories. The sensor shall be installed in supply air duct for modulating the AHU fan speed. The sensor shall be integrated with DDC / VFD of the respective AHUs.

12

-

-

... More
AIR CURTAINS

-

-

-

... More
Supply, installation and commissioning of Air curtain fan for Main entrance & Cafeteria. The door width shall be 1.2 mts and 2.4 mts height . The Noise level shall be 45 Dba @ 1mts distance.

1

-

-

... More
Supply, installation and commissioning of Chiller isolator panel suitable for Air cooled chiller - IP 55 with all accessories

3

-

-

... More
Supply, laying and termination of Cu flexible cable from chiller isolator panel to Chiller with all accessories as required

-

-

-

... More
3.5 C X 240 Sqmm

135

-

-

... More
3.5 C X 185 Sqmm

10

-

-

... More
3.5 C X 2.5 Sqmm

10

-

-

... More
FA & PA WORKS

-

-

-

... More
Fire Detection and Alarm System

-

-

-

... More
Supply, intallation, testing and Commissioning of the following system as per the Model numbers given

-

-

-

... More
Analogue addressable micro Process - controlled Fire Alarm Control Panels with interfacing box, capable of being to the central monitoring System, to monitor and integrated the following quantity of accessories like detectors, MCP's/hooters/control modules, Fault Isolation Modules, hooters, response indicators, fire/fault indicators, audio-visual signals, central processing units, complete with LCD display( (640 nos. of characters 8 lines min), zone indicating LEDs, Printer as per the detailed specification: complete with Battery backup for 48 hours in standy mode and 30 minutes in alarm (Hooter backup) condition. The system should be capable of detecting fire within 3secs as per UL 9th edition/FM approval with charger for each panel. Each loop should provide with minimum 125detectors and 125 devices. Fire panel should be integrate with IBMS system and other fire panel/repeater panel.

-

-

-

... More
Addressable power supply from OEM or equivalent approved make to be housed in suitable size of M.S. enclosure.

1

-

-

... More
Rate of Rise Heat Detectors (Thermal Detectors): Addressable analogue type Heat Detectors with solid state design with sensing element combination of fixed type and rate of rise of temperature indicating LED, mounting base etc. as per detailed specifications.

1

-

-

... More
Addressable analogue type Multisensor smoke detectors with dual chamber, solid state design, indicating LED, mounting base box etc. as per detailed specification.

-

-

-

... More
Addressable analogue type Multisensor smoke detectors with dual chamber, solid state design, indicating LED, mounting base box, gland etc. as per detailed specification. Mounting at Below False ceiling

155

-

-

... More
Addressable analogue type Multisensor smoke detectors with dual chamber, solid state design, indicating LED, mounting base box, gland etc. as per detailed specification. Mounting at Above False ceiling and direct ceiling .

424

-

-

... More
Addressable heat detector with base box and gland

4

-

-

... More
Addressable analogue type smoke detectors with dual chamber, solid state design, indicating LED, mounting base box etc. as per detailed specification.

1

-

-

... More
Addressable analogue type DUCT DETECTOR with Response indicator suitable for providing the return air path with suitable fixing accessories

12

-

-

... More
Hooter with strobe light complete with relay module and minimum 105 db audible, power supply units etc @ 3m for Audible annunciation and 75cd -110cd flashing at 1 Hz for visual indication with Control Module. The Hooter with Control Module shall be flush or surface mountable type with all accessories etc., complete and as per technical specification and shall be of UL listed.

56

-

-

... More
Addressable control module for third Party devices

1

-

-

... More
Manual pull stations with double action type of approved make with NO/NC contacts slim type and projecting out from the surface of enclosurewith glass suitable for addressable function(Resetable Type)

31

-

-

... More
Fault isolation module to electrically isolate different sections of detector loops with necessary back box

38

-

-

... More
Addressable control module to trip the AHUs, triggering the DVR with cover plate and necessary back box

12

-

-

... More
Addressable monitor module for waterflow switches and third party equipments with cover plate and necessary back box

2

-

-

... More
Response indicator for mounting on false ceiling at the entries of the cabin for indicating the operation for detectors in the above areas.

155

-

-

... More
2C X 1.5 armoured FRLS with Annealed Tinned Copper in ceiling/tray with suitable clamps and screws (RED colour)

5000

-

-

... More
2C X 2.5 armoured FRLS with Annealed Tinned Copper in ceiling/tray with suitable clamps and screws (RED colour)

1000

-

-

... More
25mm dia MS conduit with 2mm thick for laying of fire cable including necessary accessories like bend, junction box fixing of clamps etc., complete. The conduit shall be recessed in wall including chipping, roup plastering etc. (only for the Drops - MCPs)

200

-

-

... More
25mm GI Flexible conduit laid on surface / tray / MS support with complete all accessories, as per standards & specifications. The rate shall include material all accessories (like screw, nuts, clamps, Coupling, MS support, etc..) including associated civil works (like chipping, plasting, drilling etc..) and required to complete the job.

200

-

-

... More
6 A 3-Pin Socket mounted on MS Box which has to be fixed in wall as required. The Socket shall be consider as modular type

20

-

-

... More
3c x 2.5 sq mm Copper armourd FRLS cable for power supply partly laid in ceiling with clamp

500

-

-

... More
Detector cross zoning programming at panel level configuration

1

-

-

... More
Total Amount C/o to Summary

-

-

-

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
Controller complete with 10 Zone Call Station, Stem Type Microphone, 2 mm thick CRCA Sheet Powder Coated Rack for Amplifier, Dual Tone Control for Speech & Music, integration facility with Fire Alarm System, tone generator & Speech Processor with relays for activating tone & pre-recorded fire alarm messages, as specified in the Tender Specifications . The rate inclusive of Prioritymodule, selector switch etc.

1

-

-

... More
30W Horn Speakers with line matching transformers,metal enclosures and selectedable tap setting as specified in the Tender Specifications

10

-

-

... More
6 W Wall Mounted Speakers with line matching transformers, metal enclosures and selectedable tap setting as specified in the Tender Specifications.

47

-

-

... More
6 W Ceiling mounted speakers with line matching transformers, metal enclosures and selectedable tap setting as specified in the Tender Specifications for True ceiling areas

223

-

-

... More
6 W Ceiling mounted speakers with line matching transformers, metal enclosures and selectedable tap setting as specified in the Tender Specifications for false ceiling areas

155

-

-

... More
Rack Mounted minimum 480 W Power Amplifier as specified in the Tender Specifications

6

-

-

... More
Rack Mounted minimum 240 W Power Amplifier as specified in the Tender Specifications

1

-

-

... More
2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured FRLS ZH fire Survival speaker cable (BLUE Colour) as specified in the Tender Specifications ( inclusive of Ferruling & Labelling )

5000

-

-

... More
Micro phone unit with back box, call station key pad suitable for above system

2

-

-

... More
1 No. DVD player with overriding facility, Music Source Selector, with assignable priority on each channel to accept Music, Telephone, Microphone, Recorded message from Voice recorder etc., with in-built comprossor and limiter. -

1

-

-

... More
Suitable rack for mounting all the above equipment

1

-

-

... More
75mm dia GI pole with 5 mtr long for external speaker mounting including foundation, civil works etc

9

-

-

... More
Design, manufacture, supply, erect at site & commissioning of passenger & service lifts

-

-

-

... More
Note :The rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Government of Tamil Nadu for installation and commissioning of lifts before handing over the entire installation of the lift.

-

-

-

... More
Design, manufacture, supply, erect at site, test, Commission and maintain (during guarantee period of one year) Machineroom less Passenger lift with Hairline finish stainless steel with car enclosure as per specification to carry 24 (Twenty) persons capacity of load 1632 Kgs with a minimum speed of 1.5 metre per second with attendant operation including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete for servicing 3 Stopings and 3 openings.

10

-

-

... More
Design, manufacture, supply, erect at site, test, Commission and maintain (during guarantee period of one year) Machine roomless Service lift with MS sheet with powder coated finish for car enclosure as per specification with handle inside the car to carry 1500 Kg with a minimum speed of 0.5 metre per second with attendant operation including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete for servicing 3 Stopings and 3 openings.

3

-

-

... More
ELECTRICAL

-

-

-

... More
All installation works should be as complete and as directed by Employer / Employer's representative. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. All the BBT, Breakers and Panels should be withstand and designed the operating temperature suitable to local ambient, however any applicability of derating, the vendor has to be selected next /higher size. Contractor /Vendor to incorporate all the requirements specified in the BOQ, SLD, Specification and functional components for the complete satisfactory operations. The quoted rate shall inclusive of Transport, Insurance up to the site and as per tender document requirements. Note: Contractor responsibility to get liasoning work like ,approval from CEIG, arranging inspection, getting safety certificate, incorporating CEIG comments , all statutory approval from the relevant department for commissioning and with EB department associated works for the complete aspects for obtaining load sanction, meter testing, coordination for get a power supply and all associated works

-

-

-

... More
11 KV- SYSTEMS

-

-

-

... More
Supply,Installation,Testing and Commissioning of OUTDOOR Weather & Dust proof Type, floor mounting, free standing type 11KV Ring Main Gear unit made out of M.S sheet steel clad dust and vermin proof with 630A Copper Busbars, Interconnections, necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs, Termination arrangements for Incoming and Outgoing Cable of as per EB authorities approval ,earthed cable, Terminal Blocks, Earthing,Powder coated painting, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per EB Requirements comprising of the following. Remote Communication and operation facility should be incorporated as per TANGEDCO requirements.Supply and erection of 11 KV, 25 KA, 630 A, HT Outdoor Three Panel Ring Main Gear , INCOMER (2 Sources) : 11kV, 630A, 500MVA Load break Switch with necessary required accessories - 2Nos OUTGOING : 11kV, 630A, 500MVA vaccum Circuit Breaker with necessary required accessories : 1No The RMG panel shall be manufactured as required by the electrical authorities with all necessary approval approval shall be obtained including testing & commissioning and any additional features required by the supply authorities shall be carried out at no extra cost. Rate shall inclusive of factory witness test as specified in the technical specification and all necessary test to satisfy the Tangedco /CEIG Requirements. Erection shall inclusive of foundation and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as perTANGEDCO/CEIG Requirements . Metering Box with Associated componenets should complete as per EB required specification with complete accessoreis

1

-

-

... More
Supply,Installation,Testing and Commissioning of outdoor type Weather & Dust proof Type, floor mounting, free standing 11KV HT Panel made out of M.S sheet steel clad dust and vermin proof with 630A Aluminium Bus bars, Interconnections, necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, Surge Supressors,CTs, PT with necessary control fuses/MCBs, Termination arrangements for Incoming and Outgoing Cable of 11 kV 3Core 240 Sq mm XLPE Alu.Armoured (earthed) cable, Terminal Blocks, Earthing,Powder coated painting, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per TANGEDCO Requirements also and as comprising of the following. 11kV, 630A, 500MVA VCB (Vacuum Circuit Breaker)with necessary required accessories - 1No With necessary Aluminium bus bars and metering as per shown in the drawing ,phase indication lamp, MCB and switch control etc. with provision for accommodating 11kV, PT, CT metering, all protection relays with necessary C.T. and also refer as per the detailed specification & Single Line diagram attached. Panel should be extendable type. The HT Panel shall be manufactured as specified in the standard ,electrical authorities requirements. Approval shall be obtained including testing & commissioning and any additional features required by the supply authorities shall be carried out at no extra cost. The Panel shall be designed for extendable in future. Note:-The panel should be having feature for the monitoring breaker status like ON, OFF, TRIP status and meters relay status to BMS integration. Maximum demand controller , Energy consumption meter etc. .Rate shall inclusive of factory witness test as specified in the technical specification and all necessary test to satisfy the TNEB/CEIG Requirements.Erection shall inclusive of foundation and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per CMDA/TANGEDCO/CEIG Requirements .

1

-

-

... More
Supply, Installation, Testing and Commissioning of outdoor type three VCB panel floor mounting, free standing 11KV HT Panel made out of M.S sheet steel clad dust and vermin proof with 630A Aluminium Busbars, Interconnections, necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs, Termination arrangements for Incoming and Outgoing Cable of 11 kV 3Core 240/185 Sq.mm XLPE Alu.Armoured earthed cable, Terminal Blocks, Earthing,Powder coated painting, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per standard/CIEG/ requirements also and as per below INCOMER : 11kV, 630A, 500MVA VCB (Vaccum Circuit Breaker)with necessary required accessories - 1 No OUTGOING : 11kV, 630A, 500MVA VCB (Vaccum Circuit Breaker with necessary required accessories : 2 Nos. With necessary Aluminium busbars and meterings as per shown in the drawing ,phase indication lamp, MCB and switch control etc. with provision for accommodating 11 kV, PT, CT meterings, all protection relays with necessary C.T. as per the detailed specification & Single Line diagram attached. Panel should be extendable type.The HT Panel shall be manufactured as required by the standard and specification , SLD requirements Jon inclusive of approval, testing & commissioning and any additional features required by the authorities shall be carried out at no extra cost. The Panel shall be designed for extendable in future. Note:- The Panel shall be designed for extendable in future. Note:-The panel should be having feature for the monitoring breaker status like ON, OFF, TRIP status and meters relay status to BMS integration. Maximum demand controller , Energy consumption meter etc. .Rate shall inclusive of factory witness test as specified in the technical specification and all necessary test to satisfy the TNEB/CEIG Requirements. Erection shall inclusive of foundation and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per CMDA/TANGEDCO/CEIG Requirements.

1

-

-

... More
Supply, erection, testing, commissioning & delivery of Supply of 1000 KVA, 11 KV / 433 V Outdoor Oil Cooled Transformer with off Circuit (As per IS 1180-Level 2) outdoor type Power Transformer, DELTA/STAR (DYn11) with all the accessories, equipment as per the detailed specification. Transformer Protection relays should be provided at each Transformer such as Transformer Buchholz relay, CTs for restricted earth fault relay, standby earth fault relay, winding temp relay, Auxiliary relays as per standards. The transformer shall be provided with cable termination box on incomer side to terminate - 11 KV 3 core 240/185 Sqmm XLPE (E) cable and suitable for terminating 1600 TPN Aluminium sandwich aluminum bus duct at Outgoing side with necessary flanges and all as per the detailed specification enclosed. The quoted rate shall inclusive of Transport, Insurance up to the site etc., and also shall be included all necessary control cables as required and also refer as per SLD & Technical specification.Rate shall inclusive of factory witness test as specified in the technical specification and all necessary test to satisfy the TNEB/CEIG Requirements. Erection shall inclusive of with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per CMDA/TNEB/CEIG Requirements.

2

-

-

... More
Additional cost for substituting off load tap changed to on load load tap changer (17 steps) for the 1000 KVA transformer ,11KV system with RTCC panel,AVR, Digital tap position Indicator and other standard accessories as required for complete satisfactory operation and CEIG/CMDA/STANDARDS Requirements .

2

-

-

... More
supply, laying, testing and commissioning of 240 sq.mm. 3 core HT XLPE 11KV (E) SISMV11E3 x 2402797 aluminium conductor individual core screened, flat steel strip armoured, PVC sheathed cable in existing hume pipes, trenches etc - HT yard to Substation area

300

-

-

... More
supply, laying, testing and commissioning of 185 sq.mm. 3 core HT XLPE 11KV (E) aluminium conductor individual core screened, flat steel strip armoured, PVC sheathed cable in existing hume pipes, trenches etc -

75

-

-

... More
Supply , erection and testing commissioning of 120-185 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 11KV (E) - EPKT 3362

4

-

-

... More
Supply , erection and testing commissioning of 240-300 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 11KV (E) - EPKT 3372

6

-

-

... More
Supply , erection and testing commissioning of 120-185 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - EPKT 3111

1

-

-

... More
Supply , erection and testing commissioning of 240-300 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - EPKT 3121

1

-

-

... More
Design, supply, erection, testing and commissioning of Battery Charger 110V DC 220 AH Trip unit combined with trickle & boost charge facilities with battery bank(SMF) & Distribution Board and as per the detailed specification / drawing enclosed . FCBC charger with DC DB suitable for the specified ( for HT 4 VCB- )

1

-

-

... More
Supply and installation of Cable Route Indicator for HT Cable

30

-

-

... More
CONTROL CABLES & TERMINATIONS : Supply, laying, testing and commissioning of following sizes of 1100 Volts Copper Multi strand Armoured Control PVC-XLPE FRLS Cables

-

-

-

... More
4C x 2.5 Sqmm

500

-

-

... More
12C x 2.5 Sqmm

250

-

-

... More
24C x 2.5 Sqmm

250

-

-

... More
3C x 4 Sqmm

300

-

-

... More
16C x 2.5 Sqmm

250

-

-

... More
CONTROL CABLES & TERMINATIONS : Supply, laying, testing and commissioning of following sizes of 1100 Volts Copper Multi strand Armoured Control PVC-XLPE FRLS Cables

-

-

-

... More
End Terminations for above sizes of Copper Armoured Control Cables with all required accessories

-

-

-

... More
4C x 2.5 Sqmm

12

-

-

... More
12C x 2.5 Sqmm

8

-

-

... More
24C x 2.5 Sqmm

8

-

-

... More
3C x 4 Sqmm

10

-

-

... More
16C x 2.5 Sqmm

8

-

-

... More
HUME PIPE FOR HT CABLES AND LT CABLE ROAD CROSSING : Supply, laying and erection of following size RCC hume pipes with necessary couplings and joints for road crossing including excavation of the trench for laying the hume pipe from existing ground level, back filling, ramping the soil, making the surface to match the original surface , inclusive of providing and laying in position the RCC Hume pipes(NP3) of approved quality and make including collars,. necessary Excavation, PCC 1:2:4 supports, Sand cushion of 150mm on all sides, Refilling with earth, Compaction and making good the level, alignment etc., complete as directed by the Engineer-in-charge. Supplying and fixing of 300mm dia NP3 class Hume pipe -

490

-

-

... More
Supplying and fixing Ductile Iron manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement, two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.1200 X1200 mm Heavy duty DI manhole cover suitable for heavy vehicle movement

12

-

-

... More
Supplying and fixing Ductile Iron manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement, two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.1000 X1000 mm Heavy duty DI manhole cover suitable for heavy vehicle movement

12

-

-

... More
Excavation of the 300mm(W) x 750mm(D) cable trench in soil including river sand cushioning (150mm thick both at top and bottom of the cable), brick protection covering (size of brick 220 x 100 x 70 mm) after laying the cable, back filling, ramming and compacting the soiled, with caution tape and cable route indicator , as required.

300

-

-

... More
Supply and providing Earth Truck for 11KV Breakers- (BUS)

1

-

-

... More
KIOSKS,MPCC PANEL , LT SUB PANELS , BUS DUCT AND RISING MAINS

-

-

-

... More
For all items in this section, the rate includes necessary supports as required at site. No extra payment will be made for the same. Rate shall inclusive of factory witness test and all accessories, breakers , control wiring, models has to be followed as per in the technical specification, drawings, bill of quantities and all necessary test to satisfy the TNEB/CEIG /Standard requirements. Erection shall inclusive all accessories including channels ,frames and Base channels etc., with complete all accessories as required for installations , satisfactory operations and as required. As mentioned in SLD, MFM with RS 485 shall be provided in all panels incomer and MPCC panel's outgoings with necessary CTs, PTs, control switches like MPCB, MCB, ELCB, RCBOs and all other necessary accessories as per the specification and drawing. All the meters should have RS 485 Modbus output for BMS integration and also All ACB & MCCB should have dedicated potential free contacts to monitor (ON/OFF) & TRIP status from BMS system. CT accuracy class shall be as mentioned at SLD. All Panel incomers and MPCC panel outgoing breakers shall be with earth fault protection and trip functions. Aluminium bus bars Current Density not less than 0.8A/Sq.mm to be considered. All panel incomer should have surge protecting device

-

-

-

... More
COMMON NOTE TO INCORPORATE MPCC panels/LT KIOSK: All the Outgoing feeder shall be ON/OFF/Trip indication lamps, emergency lockable push buttons, all ACB and MCCBs should have two (spare) potential free contactor for BMS monitoring, Combined digital type Multi function meter with RS485 port. All ACB feeders should have TNC switch. The rate shall inclusive of necessary CTs, control switches, Front operating handles etc., All switch boards shall be fabricated as per the detailed specification enclosed. Suitable size outgoing cable chamber and extra bus bars should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension of the panel board. The transformers incomer and solar incomer shall be provided with protection relays such as IDMT (2O/C + E/F), reverse power relay, phase sequence changes protection etc. The incomers breakers should be with energy releases & will measure the following parameters such as current demand, voltages, instantaneous power, power factor, power demand etc. All outgoing breakers shall be with built-in microprocessor based release with overload, short circuit, earth fault, restricted earth fault protection , stand by earth fault protection, neutral protection, with necessary CTs etc. Incoming meter for Transformer shall be with demand controller, Harmonic THD and individual harmonic display+ Regular parameters like V, I, KVA, KVAR, KW, KWH, KVARh, PF, Freq, Max, AVG All Outgoing Feeders in Main panel shall be with MFM monitoring V,I, KWH, KVARH, PF, Energy consumption reading with RS 485 BMS integration. All the meters to be connected in series thro' bus cable terminated at common meter chamber. The panel should have the provision to receive the pipe lines for proposed panel gas flooding system

-

-

-

... More
Design, supply, erection, testing and commissioning of cubicle type floor mounting main power control center made out of MS sheet enclosure with Al bus bars to match with the transformer bus size , single bus bar system, BBTchamber, interconnection, painting, earthing, protection relays etc. comprising of the following : (LT KIOSK-1 and 2 - Outdoor WP type) 1 No. 1600 Amps 4 Pole 50 kA micro processor based electrical draw out type Air circuit breaker with RS485, shunt release shutter assembly, with all other accessories. Suitable to operate auto, manual and remote operation . Instruments Panel Providing TNC switch, emergency lockable push button, Maximum demand controller cum multifunction meter with RS485, Ammeter, Voltmeter, Instantaneous over current, earth fault relay (2 O/C+ 1 E/F) ,Restricted earth fault relay(64R), necessary CTs, PTs, control MPCB/MCB/ ELCB/RCBOs, RYB Indication lamps and “ON/OFF/Trip/Rest" indicating lamp, voltage surge protection with emergency lockable push buttons. The LT Kiosk shall be suitable to connect the 1600A 4P Sandwich type AL Bus duct for the In and Out connection. Necessary provision to be made at the panel for the power consumption measurements with necessary CTs, Meter etc. 1600Amps 50 kA 4P AL bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

2

-

-

... More
Design, supply, erection, testing and commissioning of cubicle type floor mounting main power control center made out of MS sheet enclosure with Aluminium bus bars, single bus bar system, cable chamber, interconnection, painting, earthing, protection relays etc. comprising of the following : (MPCC PANEL) INCOMER: 2 Nos. 1600 Amps 4 Pole 50 kA micro processor based electrical draw out type Air circuit breaker with RS485, & 2 No 1600A 4 Pole 50 kA micro processor based electrical draw out type Air circuit breaker with RS485 , shunt release shutter assembly, reverse power protection as specified at SLD, with required protection as per regulation And 1 No 3200 Amps 4 Pole 50 kA micro processor based electrical draw out type Air circuit breaker bus coupler with RS485 with electrical and mechanical interlock bus copuler with incomers Instruments Panel Incomer : Providing TNC switch, emergency lockable push button, Maximum demand controller cum multifunction meter with RS485, Ammeter, Voltmeter, Instantaneous over current, earth fault relay (2 O/C+ 1 E/F), Restricted earth fault relay(64R with Transformer neutral ct),Phase sequence , reverse power protection for the direct transformer incomer and necessary CTs, PTs, control MPCB/MCB/ ELCB/RCBOs, RYB Indication lamps and “ON/OFF/Trip/Rest" indicating lamp, voltage surge protection with emergency lockable push buttons. and Solar incomer should have TNC switch, emergency lockable push button,MFM, indication lamps and instantaneous over current, earth fault relay (2 O/C + 1 E/F), CTs, PTs and control MPCB/MCB/ ELCB/RCBOs with all other necessary accessories and also refer the SLD. Also provide three phase CTs at the incomers for the Power factor correction with summation CTs arrangements to provide signal to the operate the Hybrid power factor panel OUTGOINGS 800A TPN MDO ACB, 50KA – 2 No 800 A TPN MDO ACB, 50KA – 7 No 800 A TPN MDO ACB, 50KA – 1 No with rerse power protection (Future Solar power connection) 630 A TPN MCCB, 50kA – 3 No 400 A TPN MCCB, 50kA – 4 No 250 A TPN MCCB, 50kA – 2 No 200 A TPN MCCB, 50kA – 1 No 3200 Amps 50 kA 4P AL bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Providing CO2 Gas flooding system to the DG sync panel with necessary accessories like tubing, discharge nozzle, CO2 cylinders, and controls , sensors , with all functional components for the complete satisfactory operation. Vendor to ensure the sensor and its control suitable to operate properly ( Internal & Esternal)with all atmospheric condition

1

-

-

... More
APFCR PANEL 1 ,2 :- 300 KVAR Supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. The panel should suitable to receive sandwich connection ,necessary flanges , bus connection to be incorporated for terminations and its accessories Incoming 800A, TPN MDO MCCB 36 KA with Auto power factor correction relay with necessary CT, control wiring etc.- 1 No. as incomer. Incomer shall have 1 No. Multifunction meter with 800A/5A CT with CL:1.0,15VA. 1 set ON,OFF,TRIP indication lamp, 1 set RYB indication lamp. Outgoing: Total 300 KVAR (10-12 Nos switching steps). 1 set of 100 KVAR (4x 25 KVAR-with Detuned filters) with 400A TP MCCB 36KA and 400A contactor & Suitable Thyrister controlled Reactors and necessary reactors. 2 sets of 50 KVAR (2x 25 KVAR R-with Detuned filters) with 200A TP MCCB 36KA and 200A contactor & Suitable Thyrister controlled Reactors and necessary reactors. 3 sets of 25 KVAR (1x 25 KVAR R-with Detuned filters) with 100A TP MCCB 36KA and 100A contactor & Suitable Thyrister controlled Reactors and necessary reactors. 2 sets of 10 KVAR (1x 10 KVAR R-with Detuned filters) with 32A TP MCCB 36KA and 40 A contactor & Suitable Thyrister controlled Reactors and necessary reactors. 1 sets of 5 KVAR (1x 5 KVAR R-with Detuned filters) with 32A TP MCCB 36KA and 40A contactor & Suitable Thyrister controlled Reactors and necessary reactors. Each set of capacitor bank in a separate compartment with necessary ventilation/Hood arrangements and weld mesh arrangements as required and mentioned in the technical spec.With necessary Aluminium bus bars, interconnections, providing voltmeter with selector switches phase indication lamp, fuse and switch control, PF mater etc. as per the specification. Capacitors-300 kVAR 800A Amps TPN Aluminium bus bars .

2

-

-

... More
FIRE PUMP PANEL-1- Double door , Outdoor type Panel: Panel should comply the the CEIG/Fire authority requirements: Supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. FIRE PUMP PANEL-1 Incoming 2 Nos:630A 36 kA 4P MOTORIZED MCCB with E/M interlocking arrangement Each incomers shall have 1 set - Digital Combined meter (Having the parameters of Ammeter, Voltmeter and KWH meter).1 set - LED type RYB,ON,OFF,TRIP indication lamps. 1 set -630A /5A CT CL 1.0 10VA Outgoings: 200A TPN MCCB 36KA -with suitable DOL starter as per specified load in SLD.-4 Nos. 63A TPN MCCB 36 KA with suitable DOL starter as per specified load in SLD.- 2 Nos. With necessary Aluminium bus bars, interconnection providing Digital combined meter, phase indication lamp, fuse and switch control etc. in the incomer. Note: All the Outgoing feeder shall be having 'on', off, trip' indication lamps. All switch boards shall be fabricated as per the detailed specification enclosed. Suitable size outgoing cable chamber and extra bus bars should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension of the panel board. Note:-The panel should be having provision to compatibility with IBMS BUS BAR RATING: 630A TPN 36KA for 1 sec. Aluminium bus bars (Current Density not less than 0.8A/Sq.mm.) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Earthing : 50 x 6mm Aluminium flat. Cable Entry & Exit : Top/Bottom as per site requirements. Paint Finish as per the fire authority requirement

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. MAIN LIGHTING PANEL Incoming: 630 A 4P MCCB 36 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63A TPN MCCB 36kA -3 No 125A TPN MCCB 36 kA - 5 No 250A TPN MCCB 36 kA - 3 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 630 Amps 36 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. MAIN POWER PANEL Incoming: 630 A 4P MCCB 36 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63 A TPN MCCB 36kA -1 No 250A TPN MCCB 36kA -2 No 400A TPN MCCB 36 kA - 4 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 630 Amps 36 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. UTILITY PANEL Incoming: 630 A 4P MCCB 36 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 32 A TPN MCCB 25 kA -3 No With KWH meter 63 A TPN MCCB 25 kA -10 No With KWH meter 100A TPN MCCB 25 kA - 5 No With KWH meter 125 A TPN MCCB25 kA - 1 No With KWH meter With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 630 Amps 36 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. HIGH MAST LIGHTING PANEL-1 OUTDOOR DOUBLE DOOR TYPE Incoming: 125 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 32 A TPN MCCB 16kA WITH ELM, Timer, 32A 4P contactor with A/M selector switch -13 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 125 Amps 25 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. HIGH MAST LIGHTING PANEL-2 OUTDOOR TYPE Incoming: 125 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 32 A TPN MCCB 16kA WITH ELM, Timer, 32A 4P contactor with A/M selector switch -13 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 125 Amps 25 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. EXT LIGHTING PANEL-1 OUTDOOR TYPE Incoming: 125 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63 A TPN MCCB 16 kA WITH ELM - 7No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 125 Amps 25 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. ELSB Incoming: 100 A 4P-2N MCCB 16 kA with all connected accessories – 2 No.as incomer With interlock Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 32 A TP+2N MCCB 16 kA - 9 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 200 Amps 16 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LSB G/1, 1/1, and 2/1 (3Sections) Incoming:125 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63 A TPN MCCB 16 kA - 4 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 125 Amps 16 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

9

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. PSB G/1,2,2 1/1,2,3 & 2/1 ,2,3, Incoming:315 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63 A TPN MCCB 16 kA - 15 No with KWH meter With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 315 Amps 16 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

9

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. CHILLER PUMP PANEL-1- OUTDOOR TYPE Incoming:125 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63 A TPN MCCB 16 kA - 5 No 32 A TPN MCCB 16 kA - 3 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 125 Amps 16 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

1

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. VENTILATION PANEL-1,2,3 - OUTDOOR TYPE Incoming:125 A 4P MCCB 25 kA with all connected accessories – 1 No.as incomer Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 32 A TPN MCCB 25 kA - 9 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 125 Amps 16 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

3

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LIFT PANEL-1 AND 2 OUTDOOR TYPE Incoming: 250A 4P- MCCB 36 kA with all connected accessories – 2 No.as incomer With interlock Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 63 A TPN MCCB 25 kA - 10 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber/any common feeder and all as per the specifications and drawings. 250 Amps 25 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

2

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. UTILITY LIGHTING SWITCH BOARD ( Wall Mounted) Outdoor , FACADE SWITCH BOARD- OUTDOOR TYPE Incoming: 63A 4P- MCCB 16 kA with all connected accessories – 2 No.as incomer With interlock Outgoing - All outgoing feeders should be provided with ON/OFF/Trip indication lamp with protection MCB 16 A DP MCB 10 kA - 12 No With necessary AL bus bars, interconnections, providing Combined Digital type Multifunction Meter with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCBs should have cable chamber/any common feeder and all as per the specifications and drawings. 63 Amps 16 kA TPN al bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

2

-

-

... More
total panel cost

-

-

-

... More
SANDWICH BUSDUCT AND RISING MAINS All installation works should be as complete and as directed by Employer / Employer's representative. The rate includes necessary connected minor civil works if required. Necessary supports as required at site condition and as per the OEM recommendation. No extra payment will be made for the same.

-

-

-

... More
Design, supply, erection, testing and commissioning of 1600 Amps 50 kA Outdoor sandwich type AL 4P bus duct with two separate runs of external earth bus bar in the bus duct should be provided with same capacity of Neutral bus bar for entire length of bus duct and the same shall be capable of either withstanding the fault current for 1 minute or half the size of phase bus bar, whichever is higher and suitable support from ceiling as per the detailed specification enclosed. The bus duct should be with straight run, 90 deg. horizontal and Vertical bends., bus bar trunking fittings (elbow, tees, end End (Cable) feed Box, end flanges at both ends, bus connection, fire barrier , horizontal fixing devices,etc. The horizontal runs of bus bar trunking system shall be supported by hangers as per OEM recommendation, Engineer in charge instruction. Vertical runs of bus bar trunking system shall be supported as per OEM recommendation and Engineer in charge instructions . The bus duct shall run from Transformer to KIOSK-1 and 2 The bus duct shall be fabricated as per the detailed specification enclosed.

20

-

-

... More
Design, supply, erection, testing and commissioning of 1600 Amps CU flexible joints suitable to connect Transformer/BBT connections ( sandwich type 4P CU bus duct)/Panels at end terminals including all connecting accessories suitable to similar or bi -metal connection .(RYBN=1 set).

4

-

-

... More
Design, supply, erection, testing and commissioning of 1600 Amps Outdoor Phase cross changeover box suitable for sandwich type 4P AL bus duct including all accessories. (it will operate in case of phase change over is required as per site condition) (RYBN=1 set)

2

-

-

... More
RISNG MAINS AND TAP-OFF BOXES

-

-

-

... More
Note : Rising main and Its associated breakers shall be Type test panels with indication ,lamps, DSEM- with RS485 , ON//OFF/TRIP status for BMS monitoring . The rising main should inclusive of ,elbow, tees, end End (Cable) feed Box, end flanges, bus connection, flexible bus connection, fire barrier , horizontal fixing devices,etc. Contractor to incorporate all accessories, mounting vertical and horizontal supports, suitable adopter boxes for the tap of units , cables and for the complete functional components for the satisfactory operations

-

-

-

... More
Supply, Installation, Testing and Commissioning of 4P, 4Wire, with 100% Neutral 250A AL conductor sandwich type Rising Mains with external earthing as perOEM recommendation, Plug in Point at every 500mm, Fire Barriers at every Floor Crossing : Indoor : 25kA The product shall be based on Temp. rise & not on current density and as per technical specification and drawing. Each floor should have minimum three number taping points at a rising main

75

-

-

... More
Supply, Installation, Testing and Commissioning of 4P, 4Wire, with 100% Neutral - 400A AL conductor sandwich type Rising Mains with earthing as per OEM recommendation, Plug in Point at every 500mm, Fire Barriers at every Floor Crossing : Indoor : 36kA The product shall be based on Temp. rise & not on current density and as per technical specification and drawing. Each floor should have minimum three number taping points at a rising main

75

-

-

... More
End Covers for rising mains

7

-

-

... More
Mounting Brackets (Recommended Each per 1 to 1.5 Mtrs) with spring loaded support

160

-

-

... More
315A Tap Off Box with 36kA 4P MCCB with indication lamp and energy meter- with RS 485 port

9

-

-

... More
250A Tap Off Box with 36kA 4P MCCB with indication lamp and energy meter- with RS 485 port

11

-

-

... More
125A Tap Off Box with 36 kA 4P MCCB with indication lamp and energy meter - with RS 485 port

4

-

-

... More
100A Tap Off Box with 25 kA 4P MCCB with indication lamp and energy meter - with RS 485 port

18

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor/Wall mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LPRM-1 250 A 4P MCCB 25 KA with LSIG and all connected accessories – With necessary AL bus bars, suitable flexible copper connection , interconnections, providing Combined Digital type Multifunction Meter, cum Energy consumption reading with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber or adopter boxes /any common feeder and all as per the specifications and drawings. 250 Amps 25 kA TPN AL bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

3

-

-

... More
Design, Supply, erection, testing and commissioning of cubicle type floor mounting /Wall mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. PRM -1,2 &3 400 A 4P MCCB 36 KA with LSIG and all connected accessories – With necessary AL bus bars, suitable flexible copper connection , interconnections, providing Combined Digital type Multifunction Meter, cum Energy consumption reading with RS485, Surge protection device, phase indication lamps etc. in the incoming feeder and also providing ON,OFF,TRIP indication lamps with control MCB/MPCB/ELCB/RCBOs, and necessary CTs, PTs etc. All MCCBs should have two (spare) potential free contactor for BMS monitoring and the same to be wired up to the cable chamber or adopter boxes /any common feeder and all as per the specifications and drawings. 400 Amps 36 kA TPN AL bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars.

3

-

-

... More
DISTRIBUTION BOARD

-

-

-

... More
Supply, erection, earthing, testing and commissioning of the following MCB DB's IP 42 & WP type Protection Double Door type with powder coated including all interconnections and accessories like bolts, nuts and associated civil works, etc.; The rate shall be inclusive of necessary cable/conduit adopter boxes for IN and OUT wiring. 7 SEGMENTS (3 TIER) 3 PHASE DISTRIBUTION BOARD WITH MCB 4 way / 6 way / 8 way / 12 way TPMCB sheet steel distribution boards flush type / surface type/Weather proof type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating as per below mentioned MCCBS /MCB/ELCB. .For sub incomers in 3 segments with label holder and provisions for taking up cable for size not less than 35 sq.mm. Space should be covered by suitable blank plates. Contractor to incorporate the all the components specified at SLD and BOQ. All breaker shall be "C" curve type. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. The rate shall be included to fixing the DB where as in concealed / or open as per site condition. All installation works should be as complete and as directed by Employer / Employer's representative.

-

-

-

... More
ELDB (7 segment DB) - 6 WAY ( G/1, 1/1, 2/2, EX-ELDB, IBMS DB-EX AND IBMS DB-1) Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 32A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 32A DP RCBO 30mA – 3 Nos. as phase incomer Each phase incomers shall consist of 6nos.6/10A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

6

-

-

... More
LDB (7 segment DB) -4 WAY Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 32A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 32A DP RCBO 30mA – 3 Nos. as phase incomer Each phase incomers shall consist of 4 nos.6/10A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

1

-

-

... More
PDB (7 segment DB) -6 WAY Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30mA – 3 Nos. as phase incomer Each phase incomers shall consist of 6 nos 16/20A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

2

-

-

... More
PDB (7 segment DB) -4 WAY Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30mA – 3 Nos. as phase incomer Each phase incomers shall consist of 6 nos 16/20A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

5

-

-

... More
LDB (7 segment DB) - 6 WAY Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 32A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 32A DP RCBO 30mA – 3 Nos. as phase incomer Each phase incomers shall consist of 6nos.6/10A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

1

-

-

... More
ST.LDB- 1,2,3 &4 (7 segment DB) - 6 WAY ( OUTDOOR TYPE WITH SUITABLE PEDESTAL FRAME) Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63 A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30mA – 3 Nos. as phase incomer 63A DP With Timer & Contactor -3 Nos. as phase incomer Each phase incomers shall consist of 6nos.6/10A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

4

-

-

... More
LDB (7 segment DB) -6 WAY Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30/100mA – 3 Nos. as phase incomer Each phase incomers shall consist of 6 nos 6/10/16/20A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

18

-

-

... More
LDB (7 segment DB) -6 WAY ( OUTDOOR TYPE) FOR TERRACE LIGHTING Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30/100mA – 3 Nos. as phase incomer Each phase incomers shall consist of 6 nos 6/10/16/20A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

3

-

-

... More
PDB (7 segment DB) -8 WAY Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30/100mA – 3 Nos. as phase incomer Each phase incomers shall consist of 8 nos 6/10/16/20A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

18

-

-

... More
PDB (7 segment DB) -8 WAY ( OUTDOOR TYPE) FOR TERRACE POWER Supply, fixing, testing and commissioning of the double door type 6way phase segregation MCB DB comprising of the following : 63A 4P MCB 10KA (C-Curve) – 1Each as main incomer. 63A DP RCBO 30/100mA – 3 Nos. as phase incomer Each phase incomers shall consist of 8 nos 6/10/16/20A 10KA SP MCB (C-Curve) as outgoings in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

3

-

-

... More
PDB (VTPN DB) - 12 WAY: Supply, fixing, testing and commissioning of the double door type VTPN 6 way MCCB DB comprising of the following : 63 A TPN MCCB 16KA with required accessories – 1 Each as incomer. 32/20 A TP MCB 10KA – 12 Nos. as outgoings. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

1

-

-

... More
PDB (VTPN DB) - 12 WAY: - ( Outdoor Weather proof type) Supply, fixing, testing and commissioning of the double door type VTPN 6 way MCCB DB comprising of the following : 63 A TPN MCCB 16KA with required accessories – 1 Each as incomer. 32/20 A TP MCB 10KA – 12 Nos. as outgoings. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

3

-

-

... More
SPN - 8 WAY DB Supply, fixing, testing and commissioning of the double door type 4 way phase segregation MCB DB comprising of the following : 32 A DP RCBO 30mA – 1 Nos. as phase incomer 6/ 10 A SP MCB – 6 Nos. as outgoing- C Curve With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. .

3

-

-

... More
SPN - 8 WAY DB ( For TERRACE )- OUTDOOR TYPE Supply, fixing, testing and commissioning of the double door type 4 way phase segregation MCB DB comprising of the following : 32 A DP RCBO 30mA – 1 Nos. as phase incomer 6/ 10 A SP MCB – 6 Nos. as outgoing- C Curve With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

11

-

-

... More
PDB (VTPN DB) - 4 WAY: FOR GF HVLS FANS Supply, fixing, testing and commissioning of the double door type VTPN 6 way MCCB DB comprising of the following : 63 A TPN MCCB 16KA with required accessories – 1 Each as incomer. 32/20 A TP MCB 10KA – 4 Nos. as outgoings. With necessary tinned copper bus bars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc.

3

-

-

... More
ISOLATORS/MCB/COS AND STARTER PANELS :Design, Supply, Installation, testing and commissioning of MS powder coated following type isolator/ MCB /MCCB enclosure boxes suitable to terminate the specified number of cables, on, off, trip indication lamp and the boxes shall be fixed in floor/wall with suitable MS frames. IP 43 for indoor & WP -IP55 Protection with Double Door, dual enclosure type for the outdoor application with powder coated including all interconnections and accessories like bolts, nuts with and associated civil works, etc.; The rate shall be inclusive of necessary cable/conduit adopter boxes for IN and OUT wiring.

-

-

-

... More
125A 16kA 4P MCCB- (Indoor Type)

1

-

-

... More
100A 16kA 4P MCCB- (Indoor Type)

1

-

-

... More
63A 16kA 4P MCCB- (Indoor Type)

1

-

-

... More
63A 4 POLE MCB (Indoor)

4

-

-

... More
63A 4 POLE RCBO-30mA (Indoor)

6

-

-

... More
63A 4 POLE MCB (Outdoor)

2

-

-

... More
63A 4 POLE RCBO-30mA (Outdoor)

2

-

-

... More
32A 4 POLE MCB (Outdoor)

2

-

-

... More
32 A 4 POLE RCBO-30mA (Outdoor)

6

-

-

... More
32A 4 POLE MCB (Indoor)

2

-

-

... More
32 A 4 POLE RCBO-30mA (Indoor)

6

-

-

... More
20A DP MCB (Outdoor)

4

-

-

... More
20 A DP RCBO-30mA (Outdoor)

12

-

-

... More
20A DP MCB (Indoor)

8

-

-

... More
20 A DP RCBO-30mA (Indoor)

6

-

-

... More
32A 4P MCCB 16 KA with ELM with all other necessary connected accessories. (Outdoor Type )

24

-

-

... More
63A 4P MCCB 16 KA with ELM all other necessary connected accessories. (Outdoor Type )

21

-

-

... More
100A 4P MCCB 16 KA with ELM all other necessary connected accessories. (Outdoor Type )

4

-

-

... More
STARTER PANELS: Design, supplying, fixing, testing and commissioning of the following 3 phase Starter with MPCB/MCCB breaker, contactor, (type-2 co-ordination) in the suitable size Outdoor Weather proof MS enclosure. The starter panel should have ON, OFF, TRIP indication lamps, MPCBs,control MCB's, Auto / Manual selector switch, ON/OFF push button's, Ammeter with selector switch, single phase preventer, under & over voltage relay, necessary CT's, PTs, indication lamps, NO/NC for remote ON/OFF,TRIP provision to integrate with BMS systems, Auto/Manual selector switch.

-

-

-

... More
0.5 to 1.5 KW DOL (single and three phase)starter control panel with, MPCB protection remote on and off thru BMS , status monitoring to BMS

4

-

-

... More
1.1KW DOL Starter

2

-

-

... More
2.2KW DOL Starter

3

-

-

... More
3.7KW DOL Starter

2

-

-

... More
5.5KW DOL Starter

2

-

-

... More
7.5KW S/D starter

2

-

-

... More
POWER SOCKETS (SWITCHES & SOCKETS )

-

-

-

... More
Supply, Installation, Testing and Commissioning of 1 no. 6/16A three module socket controlled by 1 no 16A switch with moulded front plate, open type moulded base box/concealed type as required as per site condition and other associated accessories as required and as per the site conditions(For general Raw power/UPS Power)

295

-

-

... More
Supply, Installation, Testing and Commissioning of 1 no. 20A Industrial Plug and socket - controlled by 16/20 A DP MCB open type /concealed type as required as per site condition and other associated accessories as required and as per the site conditions(Man cooler Fan/Wall mounted fan/ Ac plug points)

26

-

-

... More
Supply, installation, Testing and commissioning of Poly carbonate enclosures WP Utility socket :3 Nos ,20A SP 3 Pin industrial type plug and socket controlled by 3 Nos DP RCBO (Raw Power) 1 No 32A TP 5 pin metal clad plug and socket controlled by 32A 4P RCBO ( Raw Power). Model Similar to Hensel PCE 10-S4

48

-

-

... More
Supply, Installation, Testing and Commissioning of 1 no. 6 A socket socket controlled by 1 no 6 A switch with moulded front plate, concealed /Open type base box and other associated accessories as required and as per the site conditions

169

-

-

... More
Supply, Installation, Testing and Commissioning of 32A 5 Pin 3 Phase interlocked plug and top weather proof raw power socket controlled by 32 A 4 P RCBO Mounted at suitable powder coated MS or Poly carbonate enclosure as per site requirements

28

-

-

... More
Supply, Installation, Testing and Commissioning of 32A 3 Pin single Phase interlocked plug and top weather proof raw power socket controlled by 32 A DP RCBO

2

-

-

... More
Supply, Installation, Testing and Commissioning of 16/20 A 3 Pin 3 Phase interlocked plug and top weather proof raw power socket controlled by 16/20 A DP RCBO Mounted at suitable powder coated MS or Poly carbonate enclosure as per site requirements

28

-

-

... More
Supply and fixing of 1 No. Data socket with necessary box and front plate and including all necessary fixing accessories a required.

10

-

-

... More
Supply and fixing of 1 No. Voice socket with necessary box and front plate and including all necessary fixing accessories a required.

10

-

-

... More
Power Wiring

-

-

-

... More
Supply and laying of 2R-4Sq.mm and 1R - 4 Sq.mm multistrand copper Fire retardant flexible conductor wire in 25mm heavy duty MS Conduit in open system in ceiling and wall with required all supply & fixing accessories. The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface. ) for power sockets

7150

-

-

... More
Supply and laying of 3CX 4 SQ.MM multistrand copper FRLS flexible cable in 25mm heavy duty MS Conduit in open system in ceiling and wall with required all supply & fixing accessories. The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface. )

3375

-

-

... More
Supply and laying of 4R-4Sq.mm and 1R -4 Sq.mm multistrand copper Fire retardant flexible conductor wire in 25mm heavy duty MS Conduit in open system in ceiling and wall with required all supply & fixing accessories. The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface. ) for power sockets

1200

-

-

... More
Supply and laying of 4C-4Sq.mm and 1R - 4 Sq.mm multistrand copper FRLS flexible cable in 25mm heavy duty MS Conduit in open system in ceiling and wall with required all supply & fixing accessories. The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface. )

1250

-

-

... More
Supply and laying of 3Core -2.5Sq.mm multistrand copper FRLS flexible cable in 25mm heavy duty MS Conduit in open system in ceiling and wall with required all supply & fixing accessories. The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface. )

2740

-

-

... More
Supply and laying of 2R-2.5Sq.mm and 1R - 2.5 Sq.mm multistrand copper Fire retardant flexible conductor wire in 25mm heavy duty MS Conduit in open system in ceiling and wall with required all supply & fixing accessories. The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface. ) for power sockets

3100

-

-

... More
Supply and laying of 5R-4Sq.mm multistrand copper Fire retardant flexible conductor laid in 25mm heavy duty PVC Conduit in concealed system with required all accessories.(6/16A General Raw power etc. including necessary bends,elbow,etc, in concealed system

1250

-

-

... More
Supply and laying of 2R-2.5Sq.mm and 1R - 2.5Sq.mm multistrand copper Fire retardant flexible conductor laid in 25mm heavy duty PVC Conduit in concealed system with required all accessories.(6/16A General Raw power etc. including necessary bends,elbow,etc, in concealed system

1750

-

-

... More
Supply and laying of 2R-4Sq.mm and 1R - 2.5Sq.mm multistrand copper Fire retardant flexible conductor laid in 25mm heavy duty PVC Conduit in concealed system with required all accessories.(6/16A General Raw power etc. including necessary bends,elbow,etc, in concealed system

1500

-

-

... More
Supply and laying of following size PVC/MS conduits in floor / wall /ceiling etc. including necessary bends,elbow,etc, in concealed system below the false ceiling on wall/floor and open system on above false ceiling.(for general purpose & for work station etc.)The rate shall includes minor civil works such as floor cutting, chipping, plastering and to make good finished surface to match with the original surface.

-

-

-

... More
110 mm dia Heavy duty PVC Duct

10

-

-

... More
63 mm dia Heavy duty PVC Duct

10

-

-

... More
40mm dia Heavy duty PVC conduits.

200

-

-

... More
32mm dia Heavy duty PVC conduits.

200

-

-

... More
25mm dia Heavy duty PVC conduits for under floor power wiring

500

-

-

... More
20mm dia Heavy duty PVC conduits.

100

-

-

... More
40mm dia Heavy duty MS conduits.

200

-

-

... More
32mm dia Heavy duty MS conduits.

200

-

-

... More
25mm dia Heavy duty MS conduits.

450

-

-

... More
20mm dia Heavy duty MS conduits.

250

-

-

... More
Supply and fixing of 100mm X100 mmx 75 mm 16 SWG MS BOX with cover , paint ( concealed /surface in floor/wall )

100

-

-

... More
Supply and laying of following runs of Fire retardant flexible conductor in existing floor trunking.

-

-

-

... More
1.5 Sq.mm copper conductor

1000

-

-

... More
2.5 Sqmm copper conductor

1000

-

-

... More
4.0 Sq.mm copper conductor

1000

-

-

... More
Supply, wiring & termination to the lighting using 3C of 2.5 sqmm Multistrand cu LSFflexible cable in existing cable tray/ conduit/Cubical panel

750

-

-

... More
Supply, wiring & termination to the lighting using 4C of 2.5 sqmm Multistrand cu LSF flexible cable in existing cable tray/ conduit/Cubical panel

750

-

-

... More
Supply, wiring & termination to the lighting using 3C of 4.0 sqmm Multistrand cu LSFflexible cable in existing cable tray/ conduit/Cubical panel

500

-

-

... More
Supply, wiring & termination to the lighting using 4C of 4.0 sqmm Multistrand cu LSF flexible cable in existing cable tray/ conduit/Cubical panel

250

-

-

... More
Point Wiring & Circuit Mains

-

-

-

... More
Supply, Wiring to the light points/ 6A plug point using 2 Runs of 2.5 Sq.mm and 1 Run of1.5 Sqmm multi strand Fire retardant flexible conductor in 25 mm MS pipe in concealed /surface mount system in ceiling and wall . The rate should inclusive of supply and fixing of 5 A modular type switch in a suitable size modular box in concealed system including wiring upto the light fittings in metal reinforced flexible hose if required as per site condition

-

-

-

... More
1 Light controlled by 1 switch

263

-

-

... More
1 Fan point controlled by 1 switch with stepped 2 M electronic regulator

6

-

-

... More
Supply, Fixing and testing of 6A socket controlled by 1 switch in existing switch board.

35

-

-

... More
Note: Group light points shall consider as a single points. The successive points will be measured in running meter only.

-

-

-

... More
Supply, wiring & termination to the lighting using 2 Runs of 2.5 sqmm and 1 Run of 1.5 sqmm multi strand PVC insulated copper conductor (FR) in 25mm FS MS conduit in open system for common area lighting circuit. Note:-The Quoted rate shall include the cost of conduit and all accessories. (switch control emergency lighting /Direct MCB control lighting /Circuit mains/ shaft lighting/Lift lighting and Successive Light points for the group control lights

4849

-

-

... More
Supply, Wiring to the light points/ 6A plug point using 2 Runs of 2.5 Sq.mm and 1 Run of1.5 Sqmm multi strand Fire retardant flexible conductor in 25 mm heavy duty PVC pipe in concealed mount system in ceiling and wall . The rate should inclusive of supply and fixing of 5 A modular type switch in a suitable size modular box in concealed system including wiring upto the light fittings in metal reinforced flexible hose if required as per site condition

-

-

-

... More
1 Light controlled by 1 switch

60

-

-

... More
1 Fan point controlled by 1 switch with regulator

6

-

-

... More
Note: Group light points shall consider as a single points. The successive points will be measured in running meter only.

-

-

-

... More
Supply, wiring & termination to the lighting using 2 Runs of 2.5 sqmm and 1 Run of 1.5 sqmm multi strand PVC insulated copper conductor (FR) in 25mm PVC conduit in open /Concealed system for common area lighting circuit. Note:-The Quoted rate shall include the cost of conduit and all accessories. (switch control emergency lighting /Direct MCB control lighting /Circuit mains/ shaft lighting/Lift lighting and Successive Light points for the group control lights

1344

-

-

... More
Supply, wiring & termination to the lighting using 3C of 2.5 sqmm XLPE/ CU/FRLS conductor armoured cable in existing cable tray for direct DB control lighting circuit. for direct MCB control General, Emergency lightings

300

-

-

... More
Supply, Wiring from DB to Circuit mains using 2 Runs of 2.5 Sqmm and 1 Run of 1.5 sqmm multi strand Fire retardant flexible conductor in suitable size PVC pipe in concealed system in ceiling and wall for circuit main & emergency lighting & staircase lighting

750

-

-

... More
Supply, wiring & termination to the lighting using 3C of 2.5 sqmm XLPE/ CU/ PVC-FRLS conductor armoured cable in existing cable tray for direct DB control lighting circuit. for direct MCB control General, Emergency lightings

4725

-

-

... More
Supply, wiring & termination to the lighting using 3C of 2.5 sqmm XLPE/ CU/FS conductor armoured cable in existing cable tray for direct DB control lighting circuit. for direct MCB control General, Emergency lightings

1425

-

-

... More
Supply, wiring & termination to the lighting using 3C of 4.0 sqmm XLPE/ CU/FS conductor armoured cable in existing cable tray for direct DB control lighting circuit. for direct MCB control General, Emergency/Normal lightings

650

-

-

... More
total of power wiring approx

-

-

-

... More
Cable Tray & MS Items

-

-

-

... More
For Cable trays designed, tested and confirming to IEC 61537, thickness of cable tray should be according to the manufacturer’s catalogue. For locally fabricated and non tested tray, thickness should be 2 mm up to span length of 1.5 meter, 2.5 mm for span length between 2 to 3 meter and 3 to 4 mm for span length between 4 and 10 meter. The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fasteners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc.' 'Integrity as per DIN 4102-12 shall be required (including fixings, anchors, cables, etc.) Cable Tray ( Hot Dip /Powered Coated) should be powder quoted as match with ceiling colour / as per Engineer in charge instructions/ as per site requirements. The rate shall inclusive of necessary suitable threaded rods,nuts & bolts, making clamp in the / purlin/Truss, anchor fasteners cable tray clamps etc., as per engineer in charge instruction and manufacturer recommendations

-

-

-

... More
Perforated type

-

-

-

... More
100mm x 50mm

3060

-

-

... More
150mm x 50mm

350

-

-

... More
300mm x 50mm

895

-

-

... More
600mm x 60mm

1105

-

-

... More
Ladder type

-

-

-

... More
For Cable trays designed, tested and confirming to IEC 61537, thickness of cable tray should be according to the manufacturer’s catalogue. For locally fabricated and non tested tray, thickness should be 2 mm up to span length of 1.5 meter, 2.5 mm for span length between 2 to 3 meter and 3 to 4 mm for span length between 4 and 10 meter. The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fasteners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc.' 'Integrity as per DIN 4102-12 shall be required (including fixings, anchors, cables, etc.) Cable Tray /ladder should be Hot Dip Galvanized. The rate shall inclusive of necessary threaded rods,nuts & bolts, making clamp in the / purlin/Truss, anchor fasteners cable tray clamps etc., as per the site requirement/Engineer in charge instruction/Manufacturer recommendation

-

-

-

... More
300mm x 50mm

15

-

-

... More
600mm x 60mm

95

-

-

... More
1000mm x 75mm

75

-

-

... More
Design, fabrication, supply, erection ,cutting, and fixing of 8 mm thick chequered plate with required MS angles , frame, flats anchors, grouting bridge consisting of columns, beams, bracings, stiffeners, ties, chequered plate covering, railing, ladder etc., with all other accessories for supporting including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc. as per site requirements / Engineers in charge instructions. for cable trench covering with structural steel components and all lead sand other materials

15

-

-

... More
Design, fabrication, supply, erection ,cutting, and fixing of powder coated/ HOT DIP GI Sheet steel of 16 SWG for connecting/covering the tray with required, clamps , angles , frame, flats anchors, grouting bridge consisting of columns, beams, bracings, stiffeners, ties, chequered plate covering, railing, ladder etc., with all other accessories for supporting including cost of all materials, clamps as per site requirements / Engineers in charge instructions. for cable tray connecting and covering the tray

570

-

-

... More
Supplying and fabricating of MS structural steel supports for various applications using U channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete , fabricating, erecting and fixing in position. .and all miscellaneous steel works as shown in the drg. or as directed by the Engineer at all heights and levels using MS angles channels, rails, tees, plates, flats, rounds, squares etc., of various sizes and other structural steel sections. The rate shall be inclusive of finishing the MS surfaces shall be painted with 2 Coats (each coat of 25 microns DFT) of red oxide zinc phosphate primer and 2 Coats (each coat of 35 microns DFT) of synthetic enamel paint of approved colour and make Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables, tools and tackles as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.

15

-

-

... More
Safety Accessories & Miscellaneous Items

-

-

-

... More
Supply and installation of Danger board as required by the Electrical authorities of size

25

-

-

... More
Supply and laying of chequered thick 2000 mmx 1000mm wide chequered rubber mat with ISI mark suitable for 11KV installation confirming to IS (Set - 5 Nos of 2mx1m mat )

7

-

-

... More
Supply & Fixing of MS sheet Caution - Entry Restricted To Authorised Persons Only near the Main entrance of the Substation. The lettering shall be Black painted on Yellow Back ground.

10

-

-

... More
Supply of tested hand gloves of 11KV grade as per IS standards

2

-

-

... More
Supply and providing first aid box with 18SWG MS sheet duly painted as approved by Indian red cross society complete with all first aid basic medicines.

4

-

-

... More
Supply and fixing of HT/LT cable route indicator

100

-

-

... More
AC Chargeable Emergency Lamp 2 x 11W PL Lamp with all connected accessories

6

-

-

... More
Supply of Highly insulated Earth/Discharge Rod as per standard

1

-

-

... More
Supply and installation of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle as per authority requirements

3

-

-

... More
Supply and fixing of shock treatment chart with glass frame

6

-

-

... More
Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms

10

-

-

... More
Supply of Aluminium adjustable type ladder , height upto 15 feet

1

-

-

... More
Supply of Aluminium adjustable type ladder , height upto 10 feet

1

-

-

... More
total

-

-

-

... More
Lightning Protection System

-

-

-

... More
For all items in this section-, the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. All items should be inclusive for supply and erection, Testing and commissioning . Since the system OEM based, Design and installation to be vetted by OEM. Necessary certificate and RSA to be submitted by OEM/Vendor

-

-

-

... More
Supply and erection of 8 mm Aluminium Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) , OBO Type No. RD 8/ALU I (5450 08 6)

3705

-

-

... More
Supply and erection of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance OBO Type No. 177 30 M8(5207 46 0 )

2635

-

-

... More
Supply and installation of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. OBO Type No. 165 MBG 8-10 ( 5218 70 0)

1880

-

-

... More
Providing and fixing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc. as required. Installed with 4 hexagonal bolts M8*25 with hexagonal nuts . Tested as per IEC 62561. OBO Type No.253 S3 FT (5312592)

310

-

-

... More
Connector: Supply and fixing For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ). OBO Type No. 249 B ST (5311705)

167

-

-

... More
Supply and fixing of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. OBO type No.F-FIX JUNIOR (5403308)

32

-

-

... More
Providing and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 )

110

-

-

... More
Supply and fixing of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer OBO Type No. 271 8-10 ( 5317 40 1 )

75

-

-

... More
Supply of and fixing of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Model Similar to OBO Type No. 5052 DIN 30X3 (5450436)

1090

-

-

... More
Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip and max 40. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Model similar to OBO Type No. 256 S6 FT (5314572 )

100

-

-

... More
Providing and fixing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts. Tested as per IEC 62561. Model similar to OBO Type No. 166 LS 70 (5226570)

75

-

-

... More
Providing and fixing of of Plastic Corrosion Protection strip: Approx. 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 (2360055)

8

-

-

... More
Supply and Erection of complete set of the followings: 1. UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Model Similar to OBO Type No. 14 3000 CCER (5450010) 2. Universal clamp made of SS to connect rod with flat conductor , Model similar to OBO Type No. 14 25 RTC (5450066) . 3.Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested . Model Similar to OBO Type No.OEC 2 25 (5450058). 4.The above arrangements shall be provided with Heavy duty earth champers of 5000kg load bearing capacity to ensure the safety of earthing system Model similar to OBO Type No.UFE (5450030) .

60

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
LIGHTING HIGH MAST SYSTEM

-

-

-

... More
Supply and installation of 16M high mast shaft in two sections suitable for 50 m/sec wind speed, with head frame, winch mounting bracket, luminaries carriage suitable to install 8-12 nos luminaries (Semi- circle with counter weight , full circle arrangement) with counter weight arrangements , mounting clamp and brackets etc. Raising ,lowering system comprising double drum winch, suitable SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lighting finial, Lightning spike if require, wiring material from JB to individual luminaire & MCB in base compartment are included and are a part of installation, foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. LED Single dome aviation obstruction light, outdoor stand mounted feeder pillar with 63/32AA 4pole RCCB with 100mA, single dial time switch, 45A TP contactor for the automatic switching of luminaries , power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and outgoing 25 & 4.0 sq. mm terminals, shallow foundation with M25 grade concrete for the high mast considering the safe soil bearing capacity at site as required as per site condition./structural engineer approval with all materials and labour, GI pipe earthing for High mast with 2.5 M long 40 mm dia GI Pipe including connection to High mast earth terminal with 25 x 3 mm GI flats with all materials and labour(2nos per mast required) , wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm, lugs, MCB and all labour,mast feeder pillar by grouting the stand in concrete. with all necessary components for the complete functional operation. Contractor to get structural approval from the Civil team for the highmast foundation

15

-

-

... More
Supply , installation , testing and commissioning of LED flood light fitting of 300 W-36000 lumens , with 7 years replacement guarantee . The fixture shall be 300W LED flood light with a system lumen output of 36000 lumens. The luminaire shall have PDC Al and with toughened glass diffuser. housing and a minimum system efficacy of 120 lumen/watt. CRI 70 with rated system lifetime of 50,000 hours at L70. It must conform to Protection Classification of IP 66, IK-07, PF0.95, THD 10%, CCT 5700K. Luminaire shall have input voltage range of 140-270V with cut off and auto restart voltage at 325V AC. Surge shall be 4kV Internal & 10 kV External. LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, Electrical Safety with Class 1 Insulation. Driver shall be potted driver with three terminals of P,L,E and both driver and luminaire shall be BIS compliance. (60 deg beam angle)

98

-

-

... More
Note: The foundation arrangement including design calculation proposed by the tenderer shall be got approved by the engineer in charge, if the design is modified the successful tenderer shall carry out the foundation according to the ENGINEER IN CHARGE directly without claiming extra rate over the quoted rates.

-

-

-

... More
Street Lighting System

-

-

-

... More
For all items in this section, the rate includes necessary connected minor civil works if required and necessary suitable loop in loop out connector,joints,glands supports as required at site. No extra payment will be made for the same. The warrantee for all lighting luminaries including LED's and drivers shall be as per the tender document requirements and BOQ . Supply, fixing, testing and commissioning of the following lighting luminaries including all necessary accessories like electronic control gear, fixing accessories, suitable size flexible cable up to the loop in loop out connection box /terminal connector, necessary 3core flexible cables, , supporting arrangements, clamps, ms angle supports, lamps, and as per the detailed technical specification enclosed. Necessary samples to be submitted for the Engineer In charge approval .The warrantee for 5 years should be provided for all lighting luminaries including LED's and drivers .

-

-

-

... More
Design, Supply, Erection of 8m Free Standing Single Arm Bracket 8 sided Orthogonally continuously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification. Bottom Pole Dia - 130mm, Top Pole Dia - 70 mm ,Thickness of Pole - 3 mm The pole should be hot dip galvanized confirming to BESN ISO 1461 with thickness of 65 Micron. The pole shall be above ground level with necessary long bracket including providing necessary base plate fixing arrangements providing . Construction of pillar accommodating MCB and switch housed in weather proof box including wiring to the light fittings with 3C -2.5 Sq.mm PVC insulated copper conductor, supplying and fixing 4 way 30 A rated terminal block loop in loop out cable arrangements, coil earthing etc. the rate shall included for cable in and out through pipe. The pole shall be as required by the Engineer in charge and complete with complete accessories also adhering to the above said specifications. Note:-The rate shall be quoted for complete set of Pole , base plate, bracket, Base foundation, Anchor fastener, internal wiring, earthing, pole earthing materials,6A DP MCB box and all necessary accessories and civil cost etc should be provided as suitable for Specified system wattage

15

-

-

... More
Design, Supply, Erection of 8m Free Standing Double Arm Bracket 8 sided Orthogonally continuously tapered structured pole with base plate of size 300 x 300 x 12mm as per IS-875 with following specification. Bottom Pole Dia - 130mm, Top Pole Dia - 70 mm ,Thickness of Pole - 3 mm The pole should be hot dip galvanized confirming to BESN ISO 1461 with thickness of 65 Micron. The pole shall be above ground level with necessary long bracket including providing necessary base plate fixing arrangements providing . Construction of pillar accommodating MCB and switch housed in weather proof box including wiring to the light fittings with 3C -2.5 Sq.mm PVC insulated copper conductor, supplying and fixing 4 way 30 A rated terminal block loop in loop out cable arrangements, coil earthing etc. the rate shall included for cable in and out through pipe. The pole shall be as required by the Engineer in charge and complete with complete accessories also adhering to the above said specifications. Note:-The rate shall be quoted for complete set of Pole , base plate, bracket, Base foundation, Anchor fastener, internal wiring, earthing, pole earthing materials,6A DP MCB box and all necessary accessories and civil cost etc should be provided as suitable for Specified system wattage

1

-

-

... More
Note: The foundation arrangement including design calculation proposed by the tenderer shall be got approved by the engineer in charge if the design is modified the successful tenderer shall carry out the foundation according to the Engineer In charge directly without claiming extra rate over the quoted rates.

-

-

-

... More
Supply, erection , testing and commissioning of gate light IP65 Supply of high-quality integrated LED gate light Luminaire with a system lumen of 2500Lm and system wattage between 25W with an efficiency 100lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be high quality pressure die cast aluminium LM6 Alloy with PF 0.95 & Surge Protection of 4KV Internal & 10 kV External. Input voltage of 140-270V. Operating temperature should be -0 to +50 Deg C. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The Ingress protection should be minimum IP 65 with an IK rating of 05. Driver Voltage range 140-270V AC

6

-

-

... More
Supply and fixing of high quality integrated LED streetlight Luminaire with a system lumen of 9100Lm and system wattage between with an efficiency 130lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be high quality pressure die cast aluminium LM6 Alloy with PF 0.95 and THD 10% & Surge Protection of 4KV Internal. Input voltage of 140-270V. Lifetime of 75,000 hours @L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 10. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature.

23

-

-

... More
Supply & laying of 40 mm dia. Class B GI pipe-

10

-

-

... More
Supply & laying of 50 mm dia. Class B GI pipe

10

-

-

... More
Supply, Installation, Testing & Commissioning of 10W LED BOLLARD with high level of durability with high impact resistance, housing shall be made of aluminium with rugged PC diffuser for outdoor application. This also has ingress protection with easy installation and comfortable soft lighting. The bollard shall be of 3000K CCT .Integral driver with a polycarbonate diffuser complying to IK10 and Class I protection. Degree of protection shall be IP 65 & IK07 Impact, with life of L70 @50K Burning Hours. The height of the bollard shall be 0.75 Mtrs. System POWER Consumption: 10W, Integral base plate. Weight: 1.9kg. System Lumen: 800lm; CRI 70. with necessary joint kit,glands,etc for loop in/out connection suitable to outdoor application .

98

-

-

... More
Supply and Erection of one number of 3 Mtr Lamp post suitable to fix 15-35 W LED post top lantern light with suitable outdoor type control box with Hot dip zinc galvanising and other necessary GI bracket / MS with powder coated bracket and all necessary fixing accessories necessary joint kit,glands,etc for loop in/out connection suitable to outdoor application , inclusive of foundation. Foundation materials & labour, Elec. Materials & Al. Paint, Labour for erection & Painting, Ladder hire charge. (ANCHOR BOLT FOUNDATION ) (Control box with loop in and loop connection with suitable connector to Luminarie shall be wired with pvc insulated multistranded 3 core flexible copper Trailing Flat/round cable) (Material ratio - 1:1.5:3). Note: The rate inclusive of necessary foundation as required by Electrical engineer in charge and structural engineer requirement.

112

-

-

... More
Supply and fixing of high quality integrated LED postop/gate light Luminaire with a system lumen of 3500Lm and an efficiency 100lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be high quality pressure die cast aluminium LM6 Alloy with PF 0.95 & Surge Protection of 4KV Internal & 10 kV External. Input voltage of 140-270V. Operating temperature should be -0 to +50 Deg C. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (16-18 Hrs. per day). The Ingress protection should be minimum IP 65 with an IK rating of 05.

112

-

-

... More
INDOOR LUMINARIES: The warrantee for all lighting luminaries including LED's and drivers shall be as per the tender document requirements and BOQ . Supply, fixing, testing and commissioning of the following lighting luminaries including all necessary accessories like electronic control gear, fixing accessories, suitable size flexible cable up to the loop in loop out connection box /ceiling rose/terminal connector, necessary plug tops, etc., down rod, chain suspender, supporting arrangements, clamps, ms angle supports, lamps, and as per the detailed technical specification enclosed. Necessary samples to be submitted for the Engineer In charge approval . The warrantee for 5 years should be provided for all lighting luminaries including LED's and drivers .

-

-

-

... More
Supply and installation of 4' LED batten with System Efficacy & System lumens of (117 lm / W)4000 lm respectively. The type of LED shall be SMD type mounted on MCPCB which is mechanically fixed (no glue pasting) with CCT of 6500K and CRI 80. The housing material shall be CRCA with polyester powder coating. The life of batten shall be 50000 hours at L70. The LED shall be of SDCM 5. The IP rating of the luminaire shall be IP40. The ambient temperature shall be 0-45deg C. The luminaire optical element shall be UV protected polycarbonate. The luminaire shall be operable from 140 - 270V AC with PF 0.9 and THD 10%.The driver shall be with in-built surge protection of 4kV. 4 feet LED Batten IP40 (For services rooms)

10

-

-

... More
Supply and installation of IP65, IK08 4' LED luminaire with special application luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with all-weather extruded aluminium housing and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The luminaire shall be with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be with system lumens of 4400 lumens and system efficacy of 120 lm / W. 120Deg LED Beam Angle, Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency85%, THD10%,, Inbuilt Surge protection in CM 4KV, Constant Current - 4 feet LED Batten IP65 (For corridor semi indoor areas ,For AHU, Electrical & services rooms)

282

-

-

... More
Supply and installation of IP20, 4' LED luminaire shall be designed to provide undisrupted lighting for dusty and humid indoor application. The luminaire shall be with CRCA housing, PC diffuser and highly efficient electronics with LED system to offer long useful life even in adverse application and environmental conditions. The system wattage shall be with system lumens of 6000 lumens and system efficacy of 125 lm / W. LED Efficacy of 150lm/W, Colour Temperature-6500K or Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency85%, THD10%, Power factor0.95, Surge of 4 kV, Driver Voltage range 140-270V AC

10

-

-

... More
Supply and installation of LED midbay symmetric wide beam (100 deg) luminaire with housing made of single piece pressure die-cast aluminium of system more than 10000lms. Luminaire should be best in class energy efficient Highbay with innovative Aluminium heat sink ensures longer service life & with dedicated optics to provide precise light distribution of symmetric wide beam angle of 110Deg. Luminaire ambient temperature shall be with +45 Deg C. Luminaire Lumen Output 10000lm, with Luminaire Efficacy of 125lm/W.The luminaire is designed to meet IP 66 and toughened glass with IK 08 classification and compliant with relevant immunity, safety and performance and EMI standards. LED Make that satisfies IEC62471 Photo biological/RoHS Standards with and LED Efficacy of 150lm/W, Colour Temperature-6500K , Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, (For banquet halls, food court, open exhibition areas)

665

-

-

... More
Supply and installation of I LED round Recessed Down lighter with a nominal system lumen output of 2000 lumens (110Lm/W) Also Safe operating voltage 140-270V AC. Power factor should be 0.95 & THD should be 10% & CRI80. Colour temperature – 6500K. LED Life should be 50,000Hrs with 2.5KV Surge Protection. Dimension: ø = 160 mm Cut-out ø = 150 mm , H=40mm. And its should be Pressure Die-Cas Al.Housing with PC Diffuser. (For Lobby, corridor areas) - Cut-out dia 150mm

414

-

-

... More
Supply and installation of LED round Recessed Down lighter with a nominal system lumen output of 1200 lumens (110Lm/W) Also Safe operating voltage 140-270V AC. Power factor should be 0.95 & THD should be 10% & CRI80. Colour temperature – 6500K. LED Life should be 50,000Hrs with 2.5KV Surge Protection. Dimension: ø = 160 mm Cut-out ø = 150 mm , H=40mm. And its should be Pressure Die-Cas Al.Housing with PC Diffuser. (For toilet areas) - Cut-out dia 150mm

101

-

-

... More
Supply and installation of LED well glass luminaire with housing made of die-cast aluminium, PC diffuser of system . The luminaire shall be with dedicated optics to provide precise light distribution of symmetric wide beam angle. The luminaire shall be designed to meet its specifications on performance & lifetime at a design ambient temperature of 45 deg C and operating temperature range 0-50° C. A specially designed heat management system to ensure luminous efficacy 120 lm/ W for the system and ensure lumen depreciation up to 30% over 50k burning hours. The luminaire is designed to meet IP 65 and IK 08 classification and is compliant with relevant immunity, safety and performance and EMI standards. The system lumens shall not be less than 8400 lumens with 5700K CCT. The CRI shall be 80. The luminaire shall be able operate from 120 - 270V AC, The luminaire shall be with inbuilt surge protection of 4kV. The driver efficiency shall be 90%. (For corridor area - semi indoor)

70

-

-

... More
Supply, installation, Testing and Commissioning of Ceiling and Wall mount LED bulk head serves as an excellent energy efficient 10W LED Bulkhead Luminaire, made of high pressure die-cast aluminium body with polycarbonate diffuser. Optic type: 120 [ Beam angle 120°], SDCM: 5. Luminaire should be with minimum system efficacy of 110 Lumen / Watt and minimum system lumen output of 1000 maintained at 70% at the end of 50,000 burning hours. The luminaire should have CRI80 and CCT of 6500K. Luminaire shall meet IP66 and IK09 protection Surge protection level until 2.5 kV. Ambient temperature range: 0 to +45

164

-

-

... More
Supply, installation, Testing and Commissioning of Ceiling and Wall mount LED surface light LED 2' LED batten (Mirror light) with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall system lumens of 1200 lumens and system efficacy of 100 lm / W. LED.

120

-

-

... More
Supply, Installation, Testing and commissioning of Sturdy & heavy duty aluminium blade for higher air delivery | Sleek & stylish design 120 spokes nickel chrome plated guard | Smooth oscillation 600MM SWEEP,100W MOTOR,1400RPM ,110CMM AIR DELIVERY wall mounted fan with Suitable Meal clad plug and socket outlet with DP MCB sheet metal Control box for local isolation

25

-

-

... More
Supply and installation of WALL MOUNT OR HANGING TYPE DUAL SIDED , Maintained 5/6 Watt LED, FIRE Exit luminaires RP , CRCA Sheet 22 SWG fabricated Housing, Epoxy polyester powder coating, White in colour, Message printed on 8mm clear acrylic, Multi facetted, electrochemically brightened & anodized aluminium reflector to enhance intensity of light, Low battery cut-off, Over charge cut-off, IP 20 with Battery Backup for 90 Minutes operation in following formats as per Layouts :  Right Arrow, Left Arrow, Down Arrow, Both sides etc. Input Supply : 230 V AC ±10% , CE/ROHS Certified , BIS Certified as per IS 10322 Part 5 Section 8 : 2013

60

-

-

... More
Supply WALL MOUNT OR HANGING TYPE SINGLE SIDED, Maintained 5/6 Watt LED, FIRE Exit luminaires RP, CRCA Sheet 22 SWG fabricated Housing, Epoxy polyester powder coating, White in colour, Message printed on 2mm clear acrylic, , Low battery cut-off, Over charge cut-off, IP 20 with Battery Backup for 90 Minutes operation in following formats as per Layouts :  Right Arrow, Left Arrow, Down Arrow, Both sides etc. Input Supply : 230 V AC ±10% CE/ROHS Certified, BIS Certified as per IS 10322 Part 5 Section 8 : 2013

45

-

-

... More
Supply WALL MOUNT/Surface mount 10W LED Emergency light fixture RP IP 20 with battery backup for 90minutes operation during main power failure, Housing 22 MS C.R.C.A. Fabricated, Epoxy Polyester powder coating; White in colour, Constant voltage charger, Red LED “on” indicates charging CE/ROHS Certified

10

-

-

... More
Supply AUTOGLO PRIME RP Series Self Maintain Photo luminescent SWGS Signage's in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive ,Life : 10- 15 Years ,Weather Proof The sign can easily be cleansed with a dry cloth or with a cloth humidified with water , Self Extinguishing, The Sign not contain any radioactive substances In toxic terms the product is considered as safe , Non Peelable, Non Scratchable,Non Breakable, Silk Screen Printed: high quality paint with UV resistance,As Per PSPA Class - A / DIN 67510 Part 2 / 60 Minutes / 700 mcdl with High photo luminescent luminous intensity Certified By Government Of India Lab For A Glow Period 24 Hrs DRDO & ARAI Certified for All require QC test to Confirm As per the IS 9457-2005 ,IS 12349 (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White approved by Local Director of Fire and Emergency services . Signage's of Size 150mm x 400mm ,displaying "Design as per site requirement"

50

-

-

... More
Loop in Loop Out connector BoX Supply of Heavy duty MS powder coated loop - in and loop out boxes of dimension min of 142 X 167 X 138 in mm with 16A Socket on the top and 40A way Clip on connector. shorting link 2 way necessary. suitable to connect in/out cable, socket connections. The Junction Box shall be insulated and made out of high grade MS box , powder coated . earth stud etc. The JB shall be rated for Degree of Ingress Protection suitable IP 54 Box shall be supplied with suitable plug top for sockets

1937

-

-

... More
Supply of Heavy duty MS powder coated loop - in and loop out Poly carbonate or MS boxes of dimension min of 142 X 167 X 138 in mm with 16A IP 65 Socket on the top and 40A way Clip on connector. shorting link 2 way necessary. suitable to connect in/out cable, socket connections. The Junction Box shall be insulated and made out of high grade MS box , powder coated or Polycarbonate suitable to outdoor conditions . earth stud etc. The JB shall be rated for Degree of Ingress Protection IP 65/66. Box shall be supplied wit suitable industrial type IP rated plug top for sockets

230

-

-

... More
Supply, fixing, testing and commissioning of heavy duty 375 mm dia single phase exhaust fan with louvers.

45

-

-

... More
Supply, fixing, testing and commissioning of five star rated 1200MM sweep ceiling fan with modular type 2 Module - stepped electronic regulator suitable to accommodate with proposed lighting switch box , 2.1 Mtr stem , fan hook and its all relevant accessories. Stem length should be as per site requirement .

25

-

-

... More
Supply , installation, testing and commissioning of new deep type recess mounted square LED luminaries LED 2X2 feet compatible with system lumens not less than 3600 lumens. The system efficacy shall be 120 lm/W. The housing shall be CRCA housing with diffused optics with PS diffuser for better distribution of light. Colour Temperature-6500K or Higher with LED binning, 120Deg LED Beam Angle, Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driv, Inbuilt Surge protection in CM ≥ 3.5KV, LED Driver with Voltage range 150-270V AC

318

-

-

... More
Supply , installation, testing and commissioning of surface LED 2X2 feet compatible with system lumens not less than 3600 lumens. The system efficacy shall be 120 lm/W. The housing shall be CRCA housing with diffused optics with PS diffuser for better distribution of light. Colour Temperature-6500K or Higher with LED binning, 120Deg LED Beam Angle, Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driv, Inbuilt Surge protection in CM ≥ 3.5KV, LED Driver with Voltage range 150-270V AC

5

-

-

... More
Cables and End Terminations

-

-

-

... More
For all items in section , the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Supply, laying of following size XLPE- FRLS insulated outer sheathed (1100 V grade) alu. armoured conductor cable partly laid in existing cable tray and partly laid in wall/ ceiling with suitable clamps. Cable tray will be measured and paid separately.

-

-

-

... More
3.5Cx400Sq.mm..Al.Arm. Cable.

800

-

-

... More
3.5Cx300Sq.mm..Al.Arm. Cable.

1100

-

-

... More
3.5Cx240Sq.mm..Al.Arm. Cable.

280

-

-

... More
3.5Cx185Sq.mm..Al.Arm. Cable.

700

-

-

... More
4 Cx185Sq.mm..Al.Arm. Cable.

100

-

-

... More
3.5Cx120Sq.mm..Al.Arm. Cable.

35

-

-

... More
3.5Cx70Sq.mm..Al.Arm. Cable.

225

-

-

... More
3.5Cx50Sq.mm..Al.Arm. Cable.

75

-

-

... More
4Cx35Sq.mm..Al.Arm. Cable.

550

-

-

... More
4Cx25Sq.mm..Al.Arm. Cable.

2500

-

-

... More
4Cx16 Sq.mm PVC Cu .Arm. Cable.

3020

-

-

... More
4Cx10 Sq.mm PVC Al.Arm. Cable.

10

-

-

... More
4Cx10 Sq.mm PVC Ar. CU. Cable.

500

-

-

... More
4Cx6 Sq.mm PVC Ar. CU. Cable.

10

-

-

... More
4Cx4 Sq.mm PVC Ar. Cu. Cable.

500

-

-

... More
3Cx6 Sq.mm PVC Ar. Cu. Cable.

10

-

-

... More
3Cx 4 Sq.mm PVC Ar. Cu. Cable.

1600

-

-

... More
3Cx2.5 Sq.mm PVC Ar. Cu. Cable.

1750

-

-

... More
1Cx 25 Sq.mm PVC UnAr. Cu. Cable.

200

-

-

... More
1Cx16 Sq.mm PVC UnAr. Cu. Cable.

200

-

-

... More
Buried Cable Laying :

-

-

-

... More
For all items in section the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Supply and laying of the following size of XLPE-_FRLS armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the three sides of the cable with bricks , caution tape and refilling the earth to make good. CMDA/PWD/CEIG regulation and Engineer in charge instruction should be followed.

-

-

-

... More
3.5Cx400Sq.mm..Al.Arm. Cable.

1600

-

-

... More
3.5Cx300Sq.mm..Al.Arm. Cable.

600

-

-

... More
3.5Cx240Sq.mm..Al.Arm. Cable.

20

-

-

... More
3.5Cx185Sq.mm..Al.Arm. Cable.

50

-

-

... More
3.5Cx120Sq.mm..Al.Arm. Cable.

10

-

-

... More
3.5Cx70Sq.mm..Al.Arm. Cable.

700

-

-

... More
3.5Cx50Sq.mm..Al.Arm. Cable.

25

-

-

... More
4Cx35Sq.mm..Al.Arm. Cable.

450

-

-

... More
4Cx25Sq.mm..Al.Arm. Cable.

5835

-

-

... More
4Cx16 Sq.mm PVC Cu .Arm. Cable.

2500

-

-

... More
4Cx10 Sq.mm PVC Al.Arm. Cable.

10

-

-

... More
4Cx10 Sq.mm PVC Ar. CU. Cable.

50

-

-

... More
4Cx6 Sq.mm PVC Ar. CU. Cable.

10

-

-

... More
4Cx4 Sq.mm PVC Ar. Cu. Cable.

500

-

-

... More
3Cx6 Sq.mm PVC Ar. Cu. Cable.

10

-

-

... More
3Cx 4 Sq.mm PVC Ar. Cu. Cable.

1250

-

-

... More
3Cx2.5 Sq.mm PVC Ar. Cu. Cable.

1400

-

-

... More
Supply and termination of the following size cables with suitable Cable glands with suitable crimping socket. (copper sockets for copper cables and Alu. Sockets for alum. Cable, earth clip, cable shroud, )

-

-

-

... More
3.5Cx400Sq.mm..Al.Arm. Cable.

24

-

-

... More
3.5Cx300Sq.mm..Al.Arm. Cable.

64

-

-

... More
3.5Cx240Sq.mm..Al.Arm. Cable.

6

-

-

... More
3.5Cx185Sq.mm..Al.Arm. Cable.

22

-

-

... More
4Cx185Sq.mm..Al.Arm. Cable.

6

-

-

... More
3.5Cx120Sq.mm..Al.Arm. Cable.

4

-

-

... More
3.5Cx70Sq.mm..Al.Arm. Cable.

16

-

-

... More
3.5Cx50Sq.mm..Al.Arm. Cable.

18

-

-

... More
4Cx35Sq.mm..Al.Arm. Cable.

10

-

-

... More
4Cx25Sq.mm..Al.Arm. Cable.

198

-

-

... More
4Cx16 Sq.mm PVC Cu .Arm. Cable.

236

-

-

... More
4Cx10 Sq.mm PVC Al.Arm. Cable.

16

-

-

... More
4Cx10 Sq.mm PVC Ar. CU. Cable.

2

-

-

... More
4Cx6 Sq.mm PVC Ar. CU. Cable.

2

-

-

... More
4Cx4 Sq.mm PVC Ar. Cu. Cable.

44

-

-

... More
3Cx6 Sq.mm PVC Ar. Cu. Cable.

2

-

-

... More
3Cx 4 Sq.mm PVC Ar. Cu. Cable.

716

-

-

... More
3Cx2.5 Sq.mm PVC Ar. Cu. Cable.

3456

-

-

... More
1Cx 25 Sq.mm PVC UnAr. Cu. Cable.

16

-

-

... More
1Cx16 Sq.mm PVC UnAr. Cu. Cable.

8

-

-

... More
UPS / Inverter

-

-

-

... More
Supply, installation, testing and commissioning of Independent 30KVA UPS system with 415V three phase input and 415V Three phase output with all required accessories & battery bank for 90 min back up for each ups with covered battery rack for all new required loads covered in this project as per the detailed technical specification enclosed. The ups shall be operate in Individual and parallel mode operation. Vendor to consider all components for the parallel operation and in depended operation. Vendor to incorporate all accessories, frame , by pass switch etc.

2

-

-

... More
Earthing System

-

-

-

... More
Supply and installation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable clamp

106

-

-

... More
Supply and installation of earth pipe electrode as per IS 3043 complete with 3 mtr long with 40mm dia 'B' class G.I. pipe and copper earth plate of size 600mm x 600mm x 3mm including watering funnel. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortar. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame and lockable facility. The plate electrode shall be filled with alternate layer of salt and charcoal as required full depth. The Cover shall be heavy duty to suit heavy vehicle movements

10

-

-

... More
Supply and laying of 60 x10 mm cu flat

410

-

-

... More
Supply and laying of 50 x 6mm cu flat

15

-

-

... More
Supply and laying of 25 x 6 mm cu flat

15

-

-

... More
Supply and laying of 25 x 3 mm cu flat

15

-

-

... More
Supply and laying of 60 x 10mm GI flat

285

-

-

... More
Supply and laying of 50 x 10mm GI flat

145

-

-

... More
Supply and laying of 50 x 6mm GI flat

2570

-

-

... More
Supply and laying of 25 x 6 mm GI flat

650

-

-

... More
Supply and laying of 25 x 3 mm GI flat for equipment's and cable tray earthing and the joints shall be provided with welding / bracing

8650

-

-

... More
Supply and laying of 8 gauge bare copper wire for Gland earthing, loop earthing in the existing surface/recessed steel conduit, DB earthing and other equipment body earthing as required.

1120

-

-

... More
Supply and laying of 10 gauge bare copper wire for Gland earthing, loop earthing in the existing surface/recessed steel conduit, DB earthing and other equipment body earthing as required.

1000

-

-

... More
Supply and laying of Earth bus with hylam sheet 0.5 mtr long using 50 x 6 mm copper flat

15

-

-

... More
Supply and laying of Earth bus with hylam sheet 0.5 mtr long using 60 x 10 mm GI flat

15

-

-

... More
DG SET WITH EXHAUST PIPE, STACK AND CONNECTED WORKS

-

-

-

... More
All installation works should be as complete and as directed by Engineer-In charge/consultant. Vendor to consider all functional components for the complete satisfactory operation as required and approval from all the relevant authority. DG should comply all requirements as per the latest standard , norms and guidelines

-

-

-

... More
Supply, Installation, Testing and Commissioning of factory assembled weathproof, acoustic type DG,d factory tested, radiator cooled, turbo charged after cooled diesel engine alternator set capable of generating full load of 1010 KVA capacity at 40° C, power factor not less than 0.8 lag, 415 Volts, 1500rpm, 3 phase, 50 Hz, AC supply and driven with diesel engine complete with all accessories such as Base frame, residential silencer, radiator, alternator capable of delivering 415 Volts, 50Hz, 3 phase, PF 0.8, 1010 KVA load, coupling arrangement of alternator with engine, coupling guard, water pump, oil pump, fuel filter, oil filter, air filter, exhaust flexible piping, fuel transfer hand pump with suitable hose pipe, battery 24 Volts and OEM recommended AH capacity, battery charging alternator, engine control panel, anti-vibration spring type mounting (quantity as per the manufacturer’s recommendation), and includes the following transport, insurance, handling, safe keeping at site etc., installation, testing and commissioning including performance tests as per Specifications . The necessary foundation will be provided by other agency.

2

-

-

... More
Note : The successful tenderer should confirm that the engine model shall be capable of delivering minimum 1010KVA and suitable for delivering 1010 KVA when coupled with alternator given below at site condition as required. Supply, Installation, Testing and Commissioning of acoustic enclosure suitable for 1 No.1010 KVA, radiator cooled diesel generator with all accessories fabricated with 16 SWG CRCA sheet steel, mineral wool insulation of high density with perforated GI sheet covering, ventilation system complete with fans and louvers, doors, inside temperature controller, inside illumination with energy efficient CFL / LED fittings, wiring for light and plug points with suitable size and number of suitable insulated copper flexible conductor cable on surface GI conduit system, I/C. MCB type distribution board, earthing complete as per the Specification and the drawing enclosed.(The above enclosure should be as per CPCB norms. The current approval certificate shall be submitted by the firm).The day tank of 990 Litres shall be mounted on a suitable pedestal with weather proof enclosure nearer to the DG set. (Excluding cost of foundation). The necessary details such as weight(dynamic & static weight), sizes shall be furnished for the execution.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Control panel outdoor, floor mounting type and 4B construction with 1600Amps, 4pole 50KA ,EDO type ,air circuit breaker with shunt release, shutter assembly, door interlock and other required accessories, copper busbar, complete set of instrument panel, protection release/relays, auto start/stop arrangement as per detailed specification. The panel shall be installed inside the acoustic enclosure. The outdoor isolator shall be suitable to receive the outdoor BBT connection with suitable flange end for the in and out terminations.

2

-

-

... More
Design, supply, erection, testing and commissioning of 1600 Amps 50 kA Outdoor sandwich type AL 4P bus duct with two separate runs of external earth bus bar in the bus duct should be provided with same capacity of Neutral bus bar for entire length of bus duct and the same shall be capable of either withstanding the fault current for 1 minute or half the size of phase bus bar, whichever is higher and suitable support from ceiling as per the detailed specification enclosed. The bus duct should be with straight run, 90 deg. horizontal and Vertical bends., bus bar trunking fittings (elbow, tees, end End (Cable) feed Box, end flanges at both ends, bus connection, fire barrier , horizontal fixing devices,etc. The horizontal runs of bus bar trunking system shall be supported by hangers as per OEM recommendation, Engineer in charge instruction. Vertical runs of bus bar trunking system shall be supported as per OEM recommendation and Engineer in charge instructions . The bus duct shall run from DG to DG O/D Isolator. The bus duct shall be fabricated as per the detailed specification enclosed.

20

-

-

... More
Design, supply, erection, testing and commissioning of 1600 Amps CU flexible joints suitable to connect Transformer/BBT connections ( sandwich type 4P CU bus duct)/Panels at end terminals including all connecting accessories suitable to similar or bi -metal connection .(RYBN=1 set).

4

-

-

... More
Design, supply, erection, testing and commissioning of 1600 Amps Outdoor Phase cross changeover box suitable for sandwich type 4P AL bus duct including all accessories. (it will operate in case of phase change over is required as per site condition) (RYBN=1 set)

2

-

-

... More
Exhaust System

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of following MS exhaust pipe and it shall be insulated with 50 mm thick mineral wool insulation (density 65 kg/cuter.) wrapped in chicken mesh and clad with 26 gauge aluminium sheet including all MS epoxy painted support structural as required suitable for 2 Nos1010 kVA DG exhaust line, as per manufacturer's recommendation up to silencer. The rate shall be inclusive of necessary, bends, flanges, gaskets, 'Y' transformation piece, fixing of residential silencer supplied along with the engine, inspection point, welding arrangements as specified to suit the site conditions. The exhaust pipe should be painted with 2 coats of high temp aluminium paint before the insulation. The tenderer shall submit calculation along with the size offered for the DG set, as detailed below, individually:-.

-

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of Providing 300mm dia. MS exhaust pipe class' B' with 50 mm thick glass wool insulation and aluminium cladding Before 'Y' Piece (the pipe dia should be indicated in mm as per the manufacturers recommendation for satisfactory operation for 1010 KVA. for 2 DG

16

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of 'Y' transformation piece with 50 mm thick glass wool insulation and aluminium cladding for joining two exhausts together, to connect to a Exhaust Stack.(the pipe dia should be indicated in mm as per the manufacturers recommendation for satisfactory operation) for 1010KVA- for 2 DG

2

-

-

... More
Design, manufacture, supply, installation, testing and commissioning of 450mm dia. MS exhaust pipe class' B' with 50 mm thick glass wool insulation and aluminium cladding on After ' Y' Piece Single Pipe for each 1010KVA DG Set to a height of 30 mtrs Pipe dia should be as per the manufacturers recommendation for satisfactory operation. for 2 DG

85

-

-

... More
Supply & fixing of 50mm thick glass wool insulation for 1010KVA engine residential silencer including cutting, fixing of glass wool, polythene covering, chicken mesh and aluminium cladding complete as per the specifications etc. as required.- for 2 DG

2

-

-

... More
Supplying and laying of 50mm / 25mm dia, C class MS pipe, fuel line for the interconnection of the reserve tanks to day tank and day tank to engine I/c, fuel transfer pumps with all accessories such as valves,non return valves, pipe lines, bend, elbow, coupling, union, plugs,flanges,bolts/nuts,gaskets, making threaded ends/welding as per the site condition laying in the following manner etc. as required. The pipe line should be suitable for the function of automatic fuel filling and the overflow fuel should be return to reserve tank from the day tank automatically .Vendor to consider all functional components with complete accessories for the functional operation as required.

-

-

-

... More
Supply and laying of 50mm dia C class MS pipe in the exposed surface the pipe line shall be painted with one coat of primer and two coats of synthetic enamel paint I/c. with necessary supports complete as required.

50

-

-

... More
Supply and laying of 25mm dia C class MS pipe in the exposed surface the pipe line shall be painted with one coat of primer and two coats of synthetic enamel paint I/c. with necessary supports complete as required.

100

-

-

... More
Supply and laying of 50mm dia C class MS pipe in soil, below 0.5 Mtrs from the ground level, the pipe line shall be painted with one coat of hot bitumen, wrapping with 3 layers of hessian cloth dipped in hot bitumen I/c. with necessary supports complete etc. as required.

50

-

-

... More
25 mm dia SS float valve for day tank

3

-

-

... More
25 mm dia brass ball valve

3

-

-

... More
50 mm dia brass ball valve

3

-

-

... More
Supply and Erection of 450 mm dia SS Bellow with necessary matching flanges suitable 1010 KVA DG set exhaust pipe

2

-

-

... More
Supplying and fixing of 990 litres secondary oil double jacket storage tank (Day Tank) for feasibility of collecting overflow oil from day oil tank to collection tank. Fabricated from 4 mm thick MS plates. Tank shall include 400 mm ID manhole cover, level indicator (Glass Tube guarded bt wire mesh cage) and flanged connection for inlet, outlet, overflow, drain, air vent, inlet fuel filter and probe provision for level controller to return automatically diesel back to bulk storage tank from the over flow tank. Tank shall be installed in civil pit at site (painted with 2 coats of red oxide primer)., with suitable size MS angle iron frame work on the existing foundation etc. as required. (Excluding cost of foundation).- 2 Nos Day tank, 1 No reserve tank

3

-

-

... More
Supply, Installation, Testing and commissioning of fuel transfer pumps 1 HP capacity, self priming, flame proof pumps 2Nos. (1No. Main and 1No. Standby) Installation of pump sets on the existing foundation, connected fuel pipe line work with necessary control valves, to fill the reserve tank from barrels and to fill the day tanks from the reserve tanks. All electrical works such as control MCB, starter, changeover switch, control and power wiring with PVC insulated copper conductor cabling, end terminations, earthing the pumps,painting,sign writing and complete as required. (Excluding cost of foundation).

1

-

-

... More
Supply and laying of necessary control cabling from generator engine panel to generator control panel and Day tank with suitable gland, crimping sockets and earthing etc. in prepared trench/ cable tray for DG sets.

-

-

-

... More
6 C x 2.5 sq.mm, XLPE copper armoured cable

100

-

-

... More
12 C x 2.5 sq.mm, XLPE copper armoured cable

500

-

-

... More
4 C x 4 sq.mm PVC XLPE copper armoured cable

400

-

-

... More
4C x 2.5 sq.sq.mm, PVC XLPE copper armoured cable

500

-

-

... More
3C x 2.5 sq.mm, PVC XLPE copper armoured cable

500

-

-

... More
3C x 1.5 sq.mm, PVC XLPE copper armoured cable

400

-

-

... More
24C x1.0 Sq.mm Screened Ar. cable as required

500

-

-

... More
4C x2.5Sq.mm Screened Ar. cable as required

150

-

-

... More
Terminations of the cables

-

-

-

... More
6 C x 2.5 sq.mm, XLPE copper armoured cable

12

-

-

... More
12 C x 2.5 sq.mm, XLPE copper armoured cable

12

-

-

... More
4 C x 4 sq.mm PVC XLPE copper armoured cable

12

-

-

... More
4C x 2.5 sq.sq.mm, PVC XLPE copper armoured cable

12

-

-

... More
3C x 2.5 sq.mm, PVC XLPE copper armoured cable

12

-

-

... More
3C x 1.5 sq.mm, PVC XLPE copper armoured cable

12

-

-

... More
24C x1.0 Sq.mm Screened Ar. cable as required

4

-

-

... More
4C x2.5Sq.mm Screened Ar. cable as required

4

-

-

... More
Supply and Installation of MS flat / angle iron supports for Exhaust pipes (30 Mtrs height from ground level) , exhaust stack with necessary accessories,stands,etc., various sizes including cutting,welding,grinding,fixing accessories and one coat of primer & two coats of enamel paints, minor civil works etc. as required.(Note: The flat / angle iron weight will be arrived on the basis of theoretical calculation only). (The DG stack should be suitable to accommodate and withstand the load of future capacity of another 2 number of 1010KVA DG set's exhaust pipe.)

20

-

-

... More
110 mm dia GI pipe as required for the functional operation

1

-

-

... More
Fuel unloading hand pump with 10 mtrs suitable hose

1

-

-

... More
Design, supply and fixing of copper lightning spike at the top of the stack with suitable supports.

1

-

-

... More
Supply, fixing of 2x12W LED cluster integral type aviation lamp at top of the Chimney with Auto ON / OFF photo cell controller, connecting wires up to aviation lamp etc.

1

-

-

... More
AUTO START - DG SYNC. and LOAD DEPENDENT START PANEL : Design, supply, testing and commissioning of Auto start and Auto syn panel with auto load sharing arrangement of Indoor, cubicle type floor mounting panel made out of MS sheet enclosure with Copper bus bars, single bus bar system, 4B construction with IP42, cable chamber, interconnection, painting, earthing, protection relays etc. comprising of the following : (DG AMF with auto Synchronizing control Panel). INCOMING : From DG: 2 Nos 1600Amps 4P 50 KA EDO ACB with UV coil, shunt release, neutral contactor as specified at SLD , shutter assembly with all other necessary accessories as specified at the specification and Schematic layout. Instrumental compartment : Providing A/M selector switch, emergency lockable push button, Multi load manager, Energy meter, Voltmeter, Instantaneous over current, earth fault relay (2 O/C+ 1 E/F), Restricted earth fault relay, Standby earth fault relay, Under voltage relay, Over voltage relay, Reverse directional power relay, Differential protection relay, Under frequency relay, Over frequency relay and Master trip relay, load dependent start relay necessary CTs, PTs, control MPCB/MCB/ ELCB/RCBOs, RYB Indication lamps and “ON/OFF/Trip/Rest" indicating lamp, and emergency lockable push buttons, GCU, Battery charger and also as per the specification and SLD. Instruments Panel: Dual type voltmeter, Dual type frequency meter, Synchronous scope, Synchronizing check devise relay, Auto load sharing relay, Voltage balance relay, Current balance relay, Frequency relay with all necessary CTs, PTs, control MPCB/MCB/ ELCB/RCBOs and as per specification and SLD. Vendor to incorporate all functional components for the satisfactory operation for DG synchronization and protection. The panels control and operation to be operated though suitable PLC with complete operation, controls and monitoring as required to the site condition. PLC shall be with Rs485 Modbus communication to interface with BMS OUTGOINGS: 1600A 4P EDO ACB 50 kA – 2 Nos suitable to connect 1600A sandwich BBT connect Flanges and 1 No 630A 4P MCCB for Fire pump panel source. Panel Main bus rating shall be 3200A . All the Outgoing feeder shall be ON/OFF/Trip indication lamps, emergency lockable push buttons, all ACB and MCCBs should have two (spare) potential free contactor for BMS monitoring, Combined digital type Multi function meter with RS485 port. Also should have digital type Ammeter& Voltmeter with RS 485, indication lamps and necessary CTs, PTs and control MPCB/MCB/ ELCB/RCBOs with all other necessary accessories and also refer the SLD.All ACB feeders should have selector switch. The rate shall inclusive of necessary CTs, control switches, Front operating handles etc., All switch boards shall be fabricated as per the detailed specification enclosed. Suitable size outgoing cable chamber and extra bus bars should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension of the panel board.

1

-

-

... More
Providing CO2 Gas flooding system to the DG sync panel with necessary accessories like tubing, discharge nozzle, CO2 cylinders, and controls , sensors , with all functional components for the complete satisfactory operation.

1

-

-

... More
STATUTORY AND LAISON

-

-

-

... More
Towards professional charges for preparation of drawings in necessary formats for approval, follow up and arranging approval of drawings, scheme by local electricity authority /Electrical Inspectorate arranging inspection, obtaining safety certificate clearance from electrical inspectorate for the installation and arranging power connection for all electrical equipments including HVAC equipments, STP, ETP, WTP, motors, starters , machines, DGs, Solar, EV charging, LPS, Lifts etc. Submission of application to EB for getting load sanction of the site required capacity, necessary follow up, getting sanction, commissioning the system. Note: It is contractor responsibility to follow up with TNEB for getting the demand approval and the demand charges will be paid by the CMDA over demand Draft.

1

-

-

... More
Preparation of submission of shop drawings and as built drawings of entire installation of the works executed need to be submitted in the colour print of required size as required in 4 sets of hard copy and two sets of soft copy in CD and pen drive. The rate shall inclusive of all necessary equipment supplied and installed by other agency also .

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.