Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Chennai Metropolitan Development Authority Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 Sep 2023
Closing Date10 Oct 2023
Tender Amount₹ 82,70,000
Costs
EMD
₹ 51,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_CMDAC_347360_2Bid Award Id
ViewTender No
01/2023-24Tender Authority
Chennai Metropolitan Development Authority ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Earth Work Excavation and deposting on banks with initial lead of 10m and initial lift of 2m in hard stiff clay stiff black cotton soil, hard red earth, shales, muram, gravel, stony earth and earth mixed with small boulders etc., as per SS 20B excluding hard rock requiring blasting etc., complete in all respects complying with relevent standard specifications and as directed by departmental officers.
405
-
-
Preparation of Sub-grade and compacting with vibratory roller having minimum 8-10 ton vibratory power roller static weight to achieve desired density of not less than 98% of MDD including forming camber and gradients watering and rolling to reach required density complete, including all material, labour, watering, machinery with all leads and lifts etc., complete
691
-
-
Flyash Brick Masonry in cement mortar 1:5 (One of Cement and Five of M-Sand) in foundation, basement and superstructure walls using Flyash bricks of size 230mm x 110mm x 75mm etc., including dewatering wherever necessary proper setting, curing etc., all complete and as directed by the departmental officers.
48.5
-
-
Brick partition wall in CM 1:3 (One of cement and three of sand) 11.50CM thickness using Second class chamber burnt bricks of size 9”x 4 3/8”x2 3/4” including both side plastering with CM 1:5 12mm thick and curing etc., all complete and as directed by the departmental officers
32
-
-
Supply and fixing of cuddapah slab of 50 mm thick both side machine polished edge and machine polished cutting for flooring using CM 1:3 (one cement three sand) including labour for fixing in position i etc., complete complying with standard specification and as directed by the Departmental Officer.
4.5
-
-
Supplying and Erecting Centering for Sides and Soffits including necessary supports and strutting up to 3.29 M height for plane surface as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90cm centre to centre and supported by casuarina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc., complete complying with the standard specification and as directed by the departmental officers.
-
-
-
For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, Portico slabs and beams, etc.,
239
-
-
For column footing plinth beam bed blocks templates staircase, steps piers raft beam raft slab etc.,
191
-
-
Supplying and filling with M-sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers.
53
-
-
Providing and Laying PCC 1:4:8 (1 of Cement, 4 of M-Sand and 8 of graded metal) using 40mm metal including cost and conveyance of all materials mixing, laying, compacting, curing etc., complete and as directed by the dept. officers.
18.5
-
-
Providing the Reinforced Cement concrete 1:1.5:3 (1 of cement 1.5 of sand and 3 broken Machine crushed stone jelly) using HBG Machine crushed stone jelly of size 20mm gauge for founding and basement including de-watering if found necessary and laid in layers etc., complete complying with standard specification and as directed by the departmental officers.
52
-
-
Supplying, fabricating and placing in position of MS/RTS Rods for grills for all RCC works including bending, tying grills and placing in position including cost of steel, binding wire etc., complete and as directed by the departmental officer.
6500
-
-
European Water Closet with "P" or "S" Trap with Double Flapped Seat and Seat Cover with Brass Hinges and 10 litre capacity PVC Low Level Flusing Tank with all internal fittings
4
-
-
supplying and fixing of Health faucet with flexible hose and wall stand , white colour polished finish etc.., all complete as directed by the departmental officers.
4
-
-
Supplying and fixing of CP Two Way Bib Cock with including cost of shellac, thread, cutting and threading wherever necessary etc. etc.,all complete as directed by the departmental officers.
4
-
-
Supplying and Fixing in position best quality approved make white glazed earthernware Hand Wash Basin of size 550 x 400mm with a pair of cast iron brackets, including cost of 15mm dia metre brass chromium plated piller tap, 32mm dia metre G.M Wheel Valve, 15mm dia brass nipple 15mm dia nylon connection etc., including fixing the wash hand basin in the wall in position with pair of CI brackets with teak wood plugs and screws and giving necessary water supply connection and painting the brackets with two coats of paint over a priming coat of anticorrosive paint including testing for leakage etc., complete complying with standard specification. The quality and colour of wash hand basin and specials should be got approved by the Executive Engineer before use on work.
4
-
-
Supplying and Fixing of Swan Neck Tap with labour all complete and as directed by the departmental officers.
4
-
-
Supplying,laying and jointing UPVC Pipes of approved quality and best variety conforming to ISS with ISI mark, of the following Sizes above Ground level upto 4M height laid properly to alignment including cutting, threading and fixing the required UPVC specials but excluding the cost of such specials and fixing to the wall with necessary TW Plugs, Clamps and screws, making holes on the wall or drilling holes in the roof and making good dismantled portion to original condition with necessary brick work, concrete and plastering wherever necessary with necessary scaffolding charges etc.,all complete as directed by the departmental officers.
-
-
-
25mm dia UPVC Pipe
30
-
-
20 mm dia UPVC Pipe
20
-
-
Supply and Fixing of Cast Iron Nahini / Floor Trap with Stainless Steel Grating all complete and as directed by the departmental officers.
4
-
-
Supply and Fixing of Brass Chromium Plated Towel Rail 60cm long and 20mm dia with Brackets all complete and as directed by the departmental officers.
4
-
-
Supplying and fixing of 110mm dia PVC Rain Water Down Fall Pipe 4 Kg /sqcm , of approved quality with necessary C.I. Gratings 110 mm dia PVC plain bend ,110 mm PVC shoe ,off sets,M.S. special clamps (heavy) teak wood plugs and screws of approved quality etc. including fixing C.I. grating 100mm dia at the junction of parapet and floor or roof slab and jointing with rubber lubricant etc, complete complying with relevant standard specifications and as directed by the departmental officers.
24
-
-
Construction of Inspection Chamber of size 60x60x60cm with necessary earth work excavation 40mm size brick jelly concretein C.M.1:4:10 ( 1 cement, 4 river sand and 10 broken brick jelly) stock brick work in C.M.1:6 (1 cement and 6 river sand) for 23cmthick wall benching channelling and plastering interior exterior and top with C.M.1:3 (1 cement and 3 river sand) 12mm thick and providing 7.5 cm thick RCC loose slab covering in CC 1:2:4 ( 1 Cement, 2 river sand and 4 blue granite broken stone jelly of 12mm to 20mm size) with necessary reinforcement and arrangements to lift for cleaning purpose etc. complete.
5
-
-
Supply of 2000 ltr Pvc Sintex water tank including cost of materials , conveyance and fixing charges etc.,
1
-
-
UPVC Window
Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) sliding Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
6.5
-
-
UPVC Ventilator Specification: Supplying and fixing UPVC ( Un Plasticized Polyvinyl Chloride) louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter. The corners and joints should be welded and cleaned. sqm.and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
1
-
-
Solid Core Flush Shutters with teakply on both side with teakwook lipping alround 35mm thick etc., all complete complying with standard Specification and as directed by the Departmental Officers.
22.5
-
-
Temple Pattern Ornamental Doors with high quality teakwood (country) with 2” minimum to 7” maximum thick Ornamental Frames, 2” thick to 5” thick Kamala (Flower Planks), Creeper,Birds, Animal Figures, Sculptures, etc. Backside 1” thick to 3” plank including necessary carving, shaping, wastage,etc., as per approved plan and design
0.4
-
-
Supplying and fixing of Aluminium door stopper with rubber bush with required screws etc..,all complete as directed by the departmental officers.
11
-
-
supplying and fixing of Hydraulic Door closer of various sizes of approved quality using Aluminium Extruded section body tubular type universal hydraulic door closer with double speed.etc..,all complete as directed by the departmental officers.
11
-
-
Solid PVC Door Shutters with frame using 19 gauge 19mm MS square tubes for styles and outer frames.15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigitdly fixed in position including necessary furniture and fittings. The over all size of styiles shall be 50mm x 30mm. The over all size of top rail, Lock and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter .etc..,all complete as directed by the departmental officers.
6.3
-
-
Plastering with CM 1:5 (1 of cement and 5 of sand) 12mm thick in all floor levels including chipping, scaffolding, curing, labour charges etc., complying with standard specification
496
-
-
Supplying and painting the ceiling with two coats of cement paint and one coat of primer as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the Executive Engineer before use of work)
185
-
-
Painting the Walls with two coats of approved cement paints in addition to over one coat of approved priemer cement paint over cement plastered wall such as, snowcem, supercem etc. including cost of brushes, paints, ladders, scaffolding, curing, scraping, washing, etc., all complete and as directed by the departmental officers.
470
-
-
Supplying and laying the floor with plain ceramic tiles of approved quality, colour and design joint free of size 305x305x6 mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The colour & quality of tiles should be got approved by the Executive Engineer before use on work.
6.1
-
-
Supplying & fixing the floor with plain ceramic tiles of approved quality, colour and design joint free of Size 600mm x 600mm x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The colour & quality of tiles should be got approved by the Executive Engineer before use on work.
190
-
-
Dadooing Ceramic Tile 300mm x 450mm x8mm best approved quality and colour in all shade of the glazed tiles in all floor over a base layer in Cement Mortar 1:2 (1 of Cement and 2 of Sand)10mm thick and laid in situ true alignment and pointed neatly with colour cement suit the colour of the tiles fixed in position without any air gap in the tiles neatly etc., complete complying with standard specification and as directed by the the departmental officers. The Colour & quality of tiles should be got approved by the Executive Engineer before use in work.
35.5
-
-
Supplying and fixing of Wall Cladding Tile 600mm x 600mm x8mmtile upto bottom of roof all complete as directed by the departmental officers
460
-
-
Providing and laying of Rubber Moulded Hydraulic Pressed Paver Block -63mm thick with C.M 1:3 pointing over Sand filling bed compacting, sand brushing and cutting, levelling, transporting etc., complete with the natural grey colour blocks.
691
-
-
Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 150mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete.
104
-
-
Supplying & Fixing of MS Grill including cost of materials, cutting, welding and fixing Charges etc., all complete and as directed by the departmental officers.
-
-
-
MS Griil bays and Gates
2520
-
-
Mild Steel Pipes
1700
-
-
Painting the New Iron Work with Two Coats of best approved first quality and colour of Synthetic Enamel Paint over the existing Red Oxide Primer of approved quality and shade.The paint should be supplied by the contractor at his own cost, etc., all Complete and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.
127
-
-
Weathering course-using Concrete broken brick jelly 20 mm gauge in pure slacked lime (No sand to be used) over RCC roof slab. The proportion of broken brick jelly to slaked lime being 32:12½ cft well beaten by wooden beaters for giving required slope and thickness required etc complete complying with standard specifications and as directed by Departmental Officers.
31
-
-
Finishing the top of roof with one course of machine pressed tiles of size 23x23x2cm of approved quality laid in CM1:3 (one cement and three M-sand) mixed with 2% of water proofing compound by weight of cement used and pointed with the same oiled mortar including mixing of red oxide etc complete complying with stadard specifications and as directed by Departmental Officers.
206
-
-
Supplying and laying final coat of cement plasterer 12mm thick with cement sand morter 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent at the rete specified by the manufacturer over coated surface etc., all complete and as directed by the departmental officers.
206
-
-
Supplying and Fixing of Galvalume Roofing Sheet 0.47mm Thickness, including cost of material, fixing of labour charges, transportation charges and Screws etc., all complete and as directed by the dept. officers.
175
-
-
Supplying and fixing of rubber moulded grey premium concrete kerb of size 450x125x300mm usung M30 concrete . The concrete shall be moulded by table Mount vibrated with polypropylene fibres at 5% and curing compound. The rate shall include cost of material transportation loading unloading charges and all taxes including necessary Earth work pointing with cm.1:3 to full depth curing thread lining etc. complete.
108
-
-
Providing and fixing of 10 mm dia mild steel for access way including anchorage in 16mm dia hole for existing concrete to a minimum depth of 100 mm with lokfix chemical etc. complete and as directed by the Engineer-in-charge.(Duct ,Shafts & UG sump,Over Head Tank and wherever necessary) Note: Rod to be fixed before spraying the surface with a fine spray
77
-
-
Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails.
90
-
-
Supplying and Fixing in position best quality PVC Soil/Waste pipes 6 Kg/Sq.cm of Various Size having ISI mark and providing leak proof joints including fixing to the wall with special PVC/MS clamps, etc., and making connection to all sanitary fittings, dismantling masonry/RCC works wherever necessary and making good the dismantled portion to the original condition, complying with standard specification etc., complete and as directed by the departmental officers.
-
-
-
110mm dia pvc pipe
24
-
-
Conveyance of Earth/Debris to a lead of within 3 km from site as directed by the Engineer inculding loading, unloading, hire charges for vehicle and other incidental charges etc., all complete as directed by the Departmental Officers.
67.2
-
-
Providing and Fixing Storage unit with openable shutter arrangements of depth 410mm using 18mm thick BWR plywood fixed in vertical member in every 80cm interval. The horizontal member will be fixed in every 60cm interval.The rear side of the unit fixed in 8mm thick both sided laminated cement particle board (bison board).The openable shutter arrangements using 18mm thick BWR plywood All edges of the plywood fixed with 6mm thick teakwood lippig. The exposed surface of the unit finished with 1mm thick lamination of approved colour with suitable adhesive (SR999) with necessary auto close hinges, Tower bolt,Handle and lock.The inner surface of the storage unit is finished with 1mm thick lamination of approved colour etc., complete.
16.2
-
-
ELECTRICAL WORKS
-
-
-
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories on wall with 3mm thick hylum sheet cover with MS Modular Junction and modular switch box and 6A modular FT switch (Crabtree / Legrand / Hager / Equivalent) with front plate on wall with painting of suitable colour for open PVC light / Fan Point (For electronic regulator) (5 Points Per Coil)
49
-
-
Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessoires in flush with wall with Modular 6 module white plate with MS modular switch box with 6A modular switch and making good of the concealed portion with suitable colour for PVC concealed light (6 Points Per Coil) (For Rooms like Bath , Toilet,& Pump room etc..)
7
-
-
Supply and fixing of 4’18W LED decorative type with electronic inbuilt driver fitting complete with TW round blocks on wall or ceiling with 20W LED tube with PVC unsheathed Copper leads from terminals to the fitting(Philips/crompton /Havels).
35
-
-
Supply and fixing of 2’9W LED decorative type with electronic inbuilt driver fitting complete with TW round blocks on wall or ceiling with 9W LED tube with PVC unsheathed Copper leads from terminals to the fitting(ORBIT ORT5-9W/ equivalent).
13
-
-
Supply and fixing of 1200 mm (48") AC ceiling fan complete with 500mm down rod on the existing clamp with stepped electronic 300W regulator.(Crompton Make/Equivalent)
14
-
-
Supply and fixing of 300 mm (12") sweep (Light duty) AC exhaust fan complete with necessary wall opening and making good of the wall.
2
-
-
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep heavy duty AC Exhaust fan
2
-
-
Supply and fixing of 1 No. 6A modular FT control switches (Crabtree / Legrand / Hager / Equivalent) in suitable MS surface modular Box on wall covered with suitable modular front plate covered with earth connection
1
-
-
Supply and fixing of 1 No. 6A modular2 in one 3pin wall socket with 6A modular FT control switches (Crabtree / Legrand / Hager / Equivalent) in suitable MS surface modular Box on wall covered with suitable modular front plate covered with earth connection
37
-
-
Supply and fixing of 1 No. 16A modular 3pin wall socket with 16A modularFT control switch (Crabtree / Legrand / Hager / Equivalent) in suitable MS surface modular Box on wall covered with suitable modular front plate covered with earth connection
38
-
-
Supply and fixing of 32 A switch and Socket in sheet enclosure on wall with earth connection
1
-
-
Supply and fixing of 25Amps DP Plug and Socket in sheet enclosure with 25A DP MCB on wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make] .
6
-
-
Supply and erection, testing and commissioning of 2.0 TR (6000 K.cal/hr) ABS Split type Air conditioner (3 star rating) confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted with hermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZ single phase AC supply inverter technology with capable of the following performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering e) Refrigerant pipe lines – 6 mtr length
The installation works for the above split type AC units include the following 1. Mounting / fitting indoor and outdoor units at their respective locations
2. Laying refrigerant pipe line of required length not exceeding 6 meters distance & connecting both units after drilling hole/holes in the wall is required, thickness of the copper tubing shall not be less than 0.7 mm
3. Installing the section pipe with expanded polythene foam tubing
4. Laying drain pipe to throw out the condensate water being formed within indoor unit
5. Leak testing the entire system unit
6. Charging refrigerant gas in the unit
7. Suitable electrical wiring with to be provided with 2.5 sq.mm PVC insulated copper wire between indoor and outdoor unit upto 6 meter length and upto switch within 3 meters of location of indoor unit. (Like (Carrier / Voltas / Blue Star / Equivalent) as directed by the department officers .
1
-
-
Supply and erection, testing and commissioning of 1.5 TR (4500 K.cal/hr) ABS Split type Air conditioner (3 star rating) confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted with hermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZ single phase AC supply inverter technology with capable of the following performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering
e) Refrigerant pipe lines – 6 mtr length The installation works for the above split type AC units include the following 1. Mounting / fitting indoor and outdoor units at their respective locations
2. Laying refrigerant pipe line of required length not exceeding 6 meters distance & connecting both units after drilling hole/holes in the wall is required, thickness of the copper tubing shall not be less than 0.7 mm
3. Installing the section pipe with expanded polythene foam tubing
4. Laying drain pipe to throw out the condensate water being formed within indoor unit
5. Leak testing the entire system unit
6. Charging refrigerant gas in the unit
7. Suitable electrical wiring with to be provided with 2.5 sq.mm PVC insulated copper wire between indoor and outdoor unit upto 6 meter length and upto switch within 3 meters of location of indoor unit. (Like (Carrier / Voltas / Blue Star / Equivalent) as directed by the department officers
2
-
-
Supply and erection, testing and commissioning of 1 TR (3000 K.cal/hr) ABS Split type Air conditioner (3 star rating) confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted with hermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZ single phase AC supply inverter technology with capable of the following performing a) Cooling b) Dehumidifying c) Air circulating
d) Filtering
e) Refrigerant pipe lines – 6 mtr length
The installation works for the above split type AC units include the following 1. Mounting / fitting indoor and outdoor units at their respective locations
2. Laying refrigerant pipe line of required length not exceeding 6 meters distance & connecting both units after drilling hole/holes in the wall is required, thickness of the copper tubing shall not be less than 0.7 mm
3. Installing the section pipe with expanded polythene foam tubing
4. Laying drain pipe to throw out the condensate water being formed within indoor unit
5. Leak testing the entire system unit
6. Charging refrigerant gas in the unit
7. Suitable electrical wiring with to be provided with 2.5 sq.mm PVC insulated copper wire between indoor and outdoor unit upto 6 meter length and upto switch within 3 meters of location of indoor unit. (Like (Carrier / Voltas / Blue Star / Equivalent) as directed by the department officers .,
3
-
-
Supply and fixing of 5 KVA slim and wall mounting (V Guard make ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split AC with necessary inter con
nection and earth connection as directed by the departmental officers. .
1
-
-
Supply and fixing of 4 KVA slim and wall mounting (V Guard make ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 1.5,1 TR split AC with necessary inter connection and earth connection as directed by the departmental officers.
.
5
-
-
Supply and fixing of MS stand for fixing outdoor unit .
6
-
-
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) .
6
-
-
Supply and fixing of water drain pipe line (1” PVC Pipe) .
12
-
-
Supply and run of 2 of 1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe clamping on wall and ceiling with 1.00sq.mm cu wire for continuous earth wire connection complete. .
640
-
-
Supply and run of 2 of 2.5sqmm (36/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe clamping on wall and ceiling with 1.00sq.mm cu wire for continuous earth wire connection complete. .
1061
-
-
Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe clamping on wall and ceiling with 1.00sq.mm cu wire for continuous earth wire connection complete. .
189
-
-
Supply and run of 4 of 16sqmm (101/0.45) PVC insulated SC unsheathed Cu. Conductor of 1100V Grade in suitable PVC rigid pipe clamping on wall and ceiling with 1.00sq.mm cu wire for continuous earth wire connection complete. .
48
-
-
Supply and clamping of 3 1/2c x 35 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
.
22
-
-
Supply and fixing of brass cable gland for 3 1/2c x 35 sq.mm PVC LTUG armoured cable with earth connection. .
2
-
-
Supply and providing cable end termination of 31/2c x 35 sqmm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete. .,
2
-
-
Supply and fixing of RJ45 I/O socket in suitable PVC module box.
.,
16
-
-
Supply and run of unarmoured CAT 6 in suitable PVC rigid pipe clamping on wall and ceiling
.,
213
-
-
Supply and fixing of RJ11 I/O socket in suitable PVC module box.
.,
5
-
-
Supply and run of 0.5mm 2 pair telephone cable in suitable PVC rigid pipe clamping on wall and ceiling .,
57
-
-
Supply and Fixing of 8 way single pole and neutral MCB sheet steel enclosure Distribution board with IP 42 protection metal Double door type with 1 No 32Amps DP MCB and 6 No's 6A to 10A SPMCB,10kA as outgoing on angle iron frame with earth connection. The MCB DB, MCB's should be with the ISI mark(like Iegrand/Hager Make) .,
3
-
-
Supply and fixing of 6 way TPN 7 Segment MCB DB with metal / acrylic door cover with IP 42 protection (Like Legrand (MDS) / Hager make with 1 No. 63A FP MCB and 63A FP ELCB as incoming, 3nos. 63 A DP MCB Isolators for sub incomers and 18 Nos.16A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCB DB and MCB's should be with the ISI mark (Like Legrand/Hager make) .,
1
-
-
Supply and fixing of 8 way TPN 7 Segment MCB DB with metal / acrylic door cover with IP 42 protection (Like Legrand (MDS) / Hager make with 1 No. 63A FP MCB and 63A FP ELCB as incoming, 3nos. 63 A DP MCB Isolators for sub incomers and 8 Nos.16A SP MCB, 16 Nos 32A MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCB DB and MCB's should be with the ISI mark (Like Legrand/Hager make) .,
1
-
-
Supply and Fixing of 3 Ph 4 way Horizontal type MCB DB with IP 42 protection Double door type DB (legrand) with 1No 63 A 4P MCB as incoming and 6 No's 32A DP MCB as outgoing with cable entry boxes on suitable AI frame work on wall with earth connection only(The MCB DB, and MCB's should be with the ISI mark Like (legrand MDS/Hager Make) .,
1
-
-
Supply and Fixing of 3 Ph 4 way Vertical type MCB DB 100 with IP 42 protection Double door type DB (legrand) with 1No 100A 4P MCB (16KA) as incoming and 3 No's 63A TP MCB 10 KA as outgoing with cable entry boxes on suitable AI frame work on wal with earth connection only(The MCB DB, and MCB's Like (legrand MDS/Hager Make) .,
1
-
-
Supply and fixng of TNEB meter board suitable for 3phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2feet x 1-1/2 feet of 12 mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V),1No. neutral link, copper earth flat of size 1"x1/4" with interconnection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete .,
1
-
-
Supply and instalation of 15 KVA true sine wave douple conversion ONLINE UPS (Three phase input/ Single phase Output)based on Low Frequendcy PWM Technology using IGBT with the following technical specification RECTIFIER:-Full wave (Shall fully meet the Specified input power requirements)
INPUT VOLTAGE :-340-460 VOLT A.C. OUTPUT VOLTAGE:- 230V AC + /- 1 % INPUT FREQUENCY :-45 Hz-55Hz OUTPUT FREQUENCY :-45 Hz-55Hz INVERSION TECHNOLOGY:-
Micro Processor controlled, PWM with instantaneous sine wave control using IGBT. CHARGER:- Built in solid automatic float-cum boost charger with constant current, constant voltage mode of charging along with current,constant voltage mode of charging along with current limiting features. Ripple in DC shall not exceed 2 % when battery is disconnected.
PROTECTIONS (in Built) i).Output under voltage. ii) Output over voltage. iii) Output over load. iv) Output short circuit. v). HRC fuses-mInput/Output/Battery. vi)Battery low Trip. vii) Battery Charging current limit. INDICATION:- i) Main ON. ii) Inverter ON. iii).UPS ON battery. iv) Load ON UPS. v).Battery LOW. vi) Mains Failure. vii) Over load Trip. viii) Inverter Trip. METERING:- i) Output AC voltage . ii) Output DC Voltage. iii) Frequency. TERMINALS:- Input -3 Pole MCB. Output- MCB Control. Temp : 0 to 40*C Humidity : 5 - 95 % RH non condensed In put power factor should be greater than 0.8 out put power factor should be 0.8 lag to unity In put Current Harmonics (THDi) should be less than 5% Over all Efficiency (On Line) should be abvove 98% Transfer time -Zero Over load cabacity: up to 110% for 1 sec,105% continuous,150% for 10 m sec. Battery:100 AH SMF(Like Exide Power safe) -30 nos The instalation work includes Battry stand and Inter connecting Cables.
.,
1
-
-
Supply and insallation maintenance free GI Earthing (Chemical Earthing) System comprising of 50mm dia and 2 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable clamp.
4
-
-
Supply and run of 25mm x 6mm GI Flat Down Condutor with necessary clamps / supports on wall / floor / ground for earth connection
86
-
-
Supply and fixing of 48W LED street light fitting with heat resistant toughened glass with IP 65 Prtection in suitable dia GI pipe (Class 'B') complete on the existing post or wall with PVC unsheathed Copper leads MS clarnnd aluminium painting
6
-
-