Central Leather Research Institute Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Central Leather Research Institute - CLRI Tender
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Oct 2024
Closing Date24 Oct 2024
Tender Amount₹ 93,75,142
Costs
EMD
₹ 1,87,503Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_209854_1Bid Award Id
ViewTender No
CLRI/23(4)/2024-25/WksTender Authority
Central Leather Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
50
-
-
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
500
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
30
-
-
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
20
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
75
-
-
Dismantling G.I. pipes/ PVC pipe / CPVC pipe / Upvc pipe / C.I pipe (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :
upto 110 mm dia pipe
350
-
-
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
8
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 5 km , for all leads including all lifts involved.
300
-
-
Repair to plaster of thickness 12mm to 20 mm in required area of all sizes, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with Readymade polymer modified non Shrinking self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. "(Make: Fosrac - Rendrerac SP 40 or equivalent )"
200
-
-
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
8
-
-
Cutting holes up to 30x30 cm in walls including making good the same:With common burnt clay F.P.S. (non modular) bricks
24
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -
1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size)
12
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below and above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
1250
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
10
-
-
Centering and shuttering including strutting, propping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform
125
-
-
Centering and shuttering including strutting, propping etc. and removal of form for
Edges of slabs and breaks in floors and walls
Under 20 cm wide
50
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
15
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor
V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
180
-
-
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
800
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
50
-
-
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant (Polyurethane sealant) over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying ISO11600:2002 (Make: " Fosroc Nitoseal PU40 ") Upto 5 mm depth and 5 mm width
50
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
20 mm nominal outer dia Pipes
180
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall
25 mm nominal outer dia Pipes
280
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall
50 mm nominal outer dia. Pipes.
5
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work 75 mm nominal inner dia. Pipes.
25
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
370
-
-
Providing and laying rectified Ceramic floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
100
-
-
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm.
8
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.
8
-
-
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore.
24
-
-
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length.
15 mm nominal bore.
16
-
-
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore (Make: Parryware/ Jaquar/ Metro)
55
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe
32 mm dia
16
-
-
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore. (Make: Parryware/ Jaquar/ Metro)
16
-
-
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore.
(Make: Parryware/ Jaquar/ Metro)
24
-
-
Providing and fixing toilet paper holder :
C.P. brass.
8
-
-
Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements. Weighing not less than 106 gms.
16
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings rrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
16
-
-
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
8
-
-
Providing and fixing PTMT grating of approved quality and colour. Circular type.
8
-
-
Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid. 150 mm nominal size square 100 mm diameter of the inner hinged round grating.
8
-
-
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter. (Make: Metro or Parryware or Jaguar or equivalent)
8
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
8
-
-
Providing and fixing gun metal gate valve with bronze ball valve(Screwed) approved quality conforming IS:554 provided with full bore, two piece design, quarter turn lever operated with S.S. Forged brass hard chrome plated ball, PTFE seating and gland packing complete all as required and directed by the Engineer-in-Charge.
25 mm nominal bore
8
-
-
Providing and fixing gun metal gate valve with bronze ball valve(Screwed) approved quality conforming IS:554 provided with full bore, two piece design, quarter turn lever operated with S.S. Forged brass hard chrome plated ball, PTFE seating and gland packing complete all as required and directed by the Engineer-in-Charge.
50 mm nominal bore .
2
-
-
Providing and fixing gun metal gate valve with bronze ball valve(Screwed) approved quality conforming IS:554 provided with full bore, two piece design, quarter turn lever operated with S.S. Forged brass hard chrome plated ball, PTFE seating and gland packing complete all as required and directed by the Engineer-in-Charge.
80 mm nominal bore .
1
-
-
Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size, complete as per manufacturers specification and direction of Engineer-in-Charge.
88
-
-
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on both side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer’s specification & drawing. 30 mm thick plain PVC door shutters.
38
-
-
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4
-
-
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
4
-
-
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 M sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 M sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 75 to 250 mm diameter
5
-
-
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm
50
-
-
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
8
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
350
-
-
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
30
-
-
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
75
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length Kiln seasoned and chemically treated hollock wood.
1.8
-
-
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. Door chowkhats .
24
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
70
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
25 mm thick (for cupboard) including ISI marked Stainless Steel butt hinges with necessary screws
45
-
-
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
70
-
-
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
45
-
-
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 30 mm thick shutters With ISI marked stainless steel butt hinges ofrequired size - Second class teak wood
30
-
-
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm
8
-
-
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm
30
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm
32
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm
32
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm
32
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 150x10 mm
40
-
-
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm
200
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
24
-
-
Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete.
8
-
-
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
8
-
-
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 50 mm
8
-
-
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete : 20 mm dia
75
-
-
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspectionof work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment shall be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
300
-
-
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
1800
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a suitable priming coat of approved epoxy primer and two coats of epoxy paint all complete as per the direction of engineer in charge.
In gratings, frames, pipe clamp stand, guard bar, ladder, railings, brackets, gates and similar works
400
-
-
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 Fixed window / ventilator / transom .
Using R1 series with frame (33mm & above ) x (35mm & above).
(Make: saint gobain or Fenesta or equivalent as apporved by EIC)
25
-
-
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 Casement window single panel with S.S. 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R2 series with frame (39mm & above) x (39mm & above) & sash (39mm & above) x (60mm & above). (Height upto 1.2 meter) (Make: saint gobain or Fenesta or equivalent as apporved by EIC)
45
-
-
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin-Charge :
With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
125
-
-
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
5
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling & dressing & finishing the top smooth.
120
-
-
Removing dry or oil bound distemper, water proofing cement paint, interior emulsion paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
3200
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1300
-
-
Distempering with 1st quality acrylic distemper (Make: " M/s. Asian Royale Shyne / Glitz /Aspira or M/s. Dulux Velvet Touch Pearl / Diamond Glow finish" or equivalent ) (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
1500
-
-
Finishing walls with 100% Premium acrylic emulsion paint (Make:M/s. Asian "Ultima Protek) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (Make:M/s. Asian "Base coat Ultima Protek primer or Trucare exterior wall primer)
1700
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
450
-
-
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a)Providing and applying fibre reinforced elastomeric liquid water proofing membrane with Acrylic polymer modified protective and waterproofing coating for concrete and masonry. (Make: " Fosroc Brushbond or or equivalent )"
(The total dry film thickness of the coating shall be not less than 2 mm )
(b) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (c)Providing and applying fibre reinforced elastomeric liquid water proofing membrane with Acrylic polymer modified protective and waterproofing coating for concrete and masonry. (Make: " Fosroc Brushbond or or equivalent )"
(The total dry film thickness of the coating shall be not less than 2 mm )
all as required to suit site conditions and complete all as per the manufacturer`s specification and all as directed by the Engineer-in-charge.
210
-
-
Providing and Laying CLC concrete blocks with cement mortar using full size blocks or half broken blocks with 10 mm to 15 mm gap, work also i/c filling the gap with cement mortar 1:4(1 cement : 4 fine sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:4 (1 cement :4 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope.complete all as required and directed by the Engineer-In-Charge
15
-
-
Providing and fixing PTMT floor Trap of ( Make: "Supreme" Size , M/s Astral ):- 110mm, Socket Type:- "S", Length:- 278mm, Depth of outlet:- 110mm & Height of Trap-118mm with necessary concrete bedding in floors with necessary cutting, placing, etc., complete all as required and directed by the Engineer-In-Charge
40
-
-
Supplying and fixing Health facet of approved as per direction of Engineer-in-Charge.
(Make: Parryware/ Jaquar/ Metro)
8
-
-
Providing & fixing the PVC corner beeding for tiles in all leads and lifts complete all as required and directed by the Engineer-In-Charge.
200
-
-
Providing and fixing PVC Premium Multipurpose Wall Mounted Storage Cabinet With Mirror(Make: M/s. Happer or M/s. Branco or M/s. Parryware or equivalent) with product minimum dimensions 11D x 30.8W x 49.5H Centimeters, work includes fixing the unit in the bath room wall surfaces safely with appropriate screws complete all as required to suit site conditions and all as directed by the Engineer-in-charge.
8
-
-
Providing and Fixing PVC - SWR pipes for sewer lines - Type :B of ISI: 13592 approved by CPWD specifications of approved make and quality with all necessary specials such as collars, elbows, tees, doors Y's, door T`s, Cowl, Shoe etc., using joining ring with solutions for necessary scaffolding etc., i/c fixing the pipe with U bolt G.I coating clamp at 1.00 m spacing , complete with all lead and lift as directed by the Engineer-in-charge. PVC pipe. 75mm dia.
80
-
-
Providing and Fixing PVC - SWR pipes for sewer lines - Type :B of ISI: 13592 approved by CPWD specifications of approved make and quality with all necessary specials such as collars, elbows, tees, doors Y's, door T`s, Cowl, Shoe etc., using joining ring with solutions for necessary scaffolding etc., i/c fixing the pipe with U bolt G.I coating clamp at 1.00 m spacing , complete with all lead and lift as directed by the Engineer-in-charge. PVC pipe. 110mm dia.
175
-
-
Providing and Fixing PVC - SWR pipes for sewer lines - Type :B of ISI: 13592 approved by CPWD specifications of approved make and quality with all necessary specials such as collars, elbows, tees, doors Y's, door T`s, Cowl, Shoe etc., using joining ring with solutions for necessary scaffolding etc., i/c fixing the pipe with U bolt G.I coating clamp at 1.00 m spacing , complete with all lead and lift as directed by the Engineer-in-charge. PVC pipe. 160mm dia.
60
-
-
providing and fixing of brass finished magic eye piece with clear visibility and suitable for 30 to 35mm door shutter including making holes in the shutter and making good as per dirction of enginner-in-charge. (as per sample approved by engineer-in-charge)
8
-
-
Providing and applying fibre reinforced elastomeric liquid waterproofing membrane coating with resilient acrylic polyurethane having sun reflectivity index of 106 on top of concrete roof by using Nitoproof 725 (Make: " Fosroc chemical " with dry film thickness of complete application/system not less than 800micron / as per the manufacturer`s requirement) in two or more coats over the existing screed concrete/Mangalore tiles roofing surface after making surface preparation neatly cleaning with wire brush, removing of dirt, cleaning the surface with jet of water, etc; by making the surface even for making the water proofing treatment. After preparing the surface preparation, work inclusive of one or more coats of priming using Nitoproof AW (Make: " Fosroc chemical " with dilution with water in the ratio of 1:1 / as per the manufacturer`s requirement) mixed with water and cement.Complete in all leads and lifts, machineries and all miscellaneous items, Highly skilled labour involved etc.; all as required to suit site conditions and complete all as per the manufacturer`s specification and all as directed by the Engineer-in-charge.
140
-
-
Providing post constructional anti termite treatment by drilling holes ½” dia at uniform intervals of 12” at the junction of walls and floors to a depth of 4” to 6” inside the building best quality anti termite solution shall be injected into these holes by using hand pump or pressure pump till its refusal. The wooden frames shall be treated with the anti termite solution and the outer periphery of the building shall be treated by making a small channel alround the building with suitable intervals after completion of the treatment all the holes drilled in the floors and walls will be closed and finishing neatly with cement mortar 1:3 and with the white cement or other suitable materials to render the surface to original condition at his own cost. The rate is inclusive of all labour and the work should be done as per IS 6313 of 1981 etc complete complying with standard specification and as directed by the departmental officers site of work.
550
-
-
Civil Part- Buy Back
-
-
-
Rate Payable by the contractor for taking away (Buy back) the existing Wooden/steel/ PVC door /window of all size along with grill & glass, etc., and the like including frame, chowkhats, etc., as is where is as basis including dismantling and removing them without damaging the adjacent walls at their risk and cost complete all as required to suit site conditions and as directed.
110
-
-
Electrical Part
-
-
-
MODULAR LIGHT/FAN PT: Wiring for light / fan / exhaust fan / call bell point with 1.5sqmm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI. box and earthing the point with 1.5sqmm. FRLS PVC insulated copper conductor single core cable etc., as required. Make: FINOLEX/ANCHOR ROMA/HAVALLS
150
-
-
Twin Control light point: Wiring for Twin control point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. Make: FINOLEX/ANCHOR ROMA/HAVALLS
8
-
-
A.C. POINT: Supplying and fixing two modular G.I box for each socket & MCB with modular plate and cover on surface/recessed including providing and fixing 25A socket outlet and 25A modular SP MCB,"C" curve including connections, testing and commissioning etc.as required.
Make: Legrand/L&T/MK
8
-
-
CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
MAKE: HAVALLS/FINOLEX/POLYCAB
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
800
-
-
CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
MAKE: HAVALLS/FINOLEX/POLYCAB
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
200
-
-
CIRCUIT WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
MAKE: HAVALLS/FINOLEX/POLYCAB
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
150
-
-
ELECTRONIC BELL/BUZZER: Supply and fixing Electronic bell/buzzer suitable for single phase,230V, complete with connection,testing etc. as required.
MAKE: ANCHOR/PHILLIPS/HAVALLS
8
-
-
MODULAR 15A SWITCH : Supplying and fixing following modular switch on the existing modular plate & switch box including connections but modular plate etc. as required.
MAKE: ANCHOR ROMA/MK/LEGRAND 15/16 amp switch
48
-
-
MODULAR 15A SOCKET : Supplying and fixing following modular socket on the existing modular plate & switch box including connections but modular plate etc. as required.
MAKE: ANCHOR ROMA/MK/LEGRAND 6 pin 5/16 amp socket outlet
48
-
-
MODULAR 5A SWITCH : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but modular plate etc. as required.
MAKE: ANCHOR ROMA/MK/LEGRAND
5/6 amp switch
80
-
-
MODULAR 5A SOCKET : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but modular plate etc. as required.
MAKE: ANCHOR ROMA/MK/LEGRAND
5/6 amp socket
80
-
-
MODULAR TV ANTENNA SOCKET: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but modular plate etc. as required.
MAKE: ANCHOR ROMA/MK/LEGRAND
TV antenna socket outlet
8
-
-
ELECTRONIC FAN REGULATOR: Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections etc. as required.
MAKE: ANCHOR ROMA/MK/LEGRAND
16
-
-
SINGLE PHASE DB : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
Make: Legrand/L&T/Havells
12 way, Double door
8
-
-
SINGLE POLE MCB FOR DBs: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.
Make: Legrand/L&T/Havells
5 amps to 32 amps Single pole
80
-
-
INCOMER FOR DB (DOUBLE POLE ISOLATOR): Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.
Make: L&T/Legrand/Havells 40A
8
-
-
SP Blanking Plate: Supplying & fixing of single pole blanking plate in the existing MCB DB complete etc. as required.
40
-
-
GI Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. MAKE: ANCHOR ROMA/MK/LEGRAND
2 Module (75 mm X 75 mm)
16
-
-
GI Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. MAKE: ANCHOR ROMA/MK/LEGRAND
3 Module (100 mmX75 mm)
48
-
-
GI Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. MAKE: ANCHOR ROMA/MK/LEGRAND
6 Module (200mm x 75mm )
40
-
-
GI Box alongwith modular base & cover plate : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches & sockets and junction box in recess etc as required. MAKE: ANCHOR ROMA/MK/LEGRAND
12 Module (200mm x 75mm )
8
-
-
LABOUR CHARGES FOR Fixing of Exhaust Fan: Installation of Exhaust fan in the exsting opening, including making good the damage, connection, testing, commissioning with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable etc. as required
8
-
-
Labour Charges for Fixing of louver/shutter for Existing exhaust fan: Extra for fixing the louvers/shutters complete with frame for a exhaust fan of all sizes
8
-
-
PVC BATTEN/ANGLE HOLDER: Supplying and fixing PVC batten/angle holder including connection etc.as required.
MAKE: ANCHOR ROMA/MK/LEGRAND
48
-
-
LABOUR CHARGES FOR FIXING OF FLUORESCENT/MIRROR LIGHT FITTING: Installation, testing and commissioning of pre-wired, fluorescent/Mirror light fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connections with 1.5sqmm FRLS PVC insulated, copper coductor, single core cable and earthing etc. as required.
24
-
-
Ceiling Fan 1200mm: Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, Ceiling fan with Brush Less Direct Current(BLDC) Motor, Class of Insulation : B, 3 No's of blades, 30 cm long down rod, 2No's canopies, shackle kit, safety rope, copper winding, Power factor not less than 0.9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min,350 RPM (tolerence as per Is:374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 deg C(max),insulation resistance morethan 2Mega ohm, suitable for 230V,50Hz, single phase AC supply, earthing etc complete as required. MAKE: Orient/Almonord/Crompton
16
-
-
PVC Pipe 32mm: Supplying and fixing of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Make: Vasavi/Avonplast/Finolex
50
-
-
CABLE Laying in the Existing System: Laying of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1KV grade of folloeing size in the existing RCC/HUME/METAL pipe as reqired.
Upto 35sqmm
25
-
-
Cable End Termination:-
Supply and makingend termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium cinductor of 1.1KV grade as required.
4x35sqmm (32mm)
2
-
-
Supply and laying of DWC Pipe:-
Supply and layin goffollowing size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.direct in groumnd (75cm below ground level) including excavation and refillinmg the trench but excluding sand cushioning and protective coveringetc.,complete as required.
63 mm dia (OD-63mm&ID51-mm nominal)
20
-
-
Potential Earth Electrode: Earthing with GI earth plate 600 mm X 600 mm X 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal/ coke and salt as required.
Make: Value Engineers/ Galaxy Earthing Electrodes.
2
-
-
EARTH WIRE FOR LOOP: Supplying and laying 6 SWG dia G.I wire on surface or in recess for loop earth pit to panel ,including connection/ termination with GI thimble with necessary earthing accessary etc., as required.
40
-
-
SUPPLY OF 4 CORE, 35 SQ MM, ALUMINIUM UG CABLE:
Supply of 4 core, 35sq mm, PVC insulated, Sheathed and armored aluminium 1100 V grade as per IS 1554 Standard UG cable, produce with necessary test certificate etc. as required. Make: Finolex/Polycab/Havells
25
-
-
REMOVAL OF ELECTRICAL ITEMS: Removing the existing connection,wires, unused metal enclosures, switch boards, fixtures,ceiling fans,exhaust fans,DB's.etc., and same have to be haneded over to department as directed by dept, Engineer.
8
-
-
EXHAUST FAN: Supply of 225mm Sweep Exhaust fan with metal type model for kitchen/bathroom complete with all accessories.. etc, as required .
Make: Havells / USHA/ Almanord/Crompton
8
-
-
20W 4Ft Light fitting : Supply of 4ft 20W 6500K 2000lumen LED/Conventional type Light fitting with fixing accessories on surface /wall etc. as required.
Make: Crompton/ Philips/Havells/Wipro
16
-
-
MIRROR LIGHT FITTING : Supply of 9W LED mirror light suitable fitting (Crompton/ Philips) to complete with all assocessories etc., as required.
Make: Crompton/ Philips/Havells/Wipro
8
-
-
18W LED Surface Fitting: Supply & fixing of 18W LED 6500K (595mmX595mm) Surface fitting round/square light suitable fitting including Installation, testing and commissioning of pre-wired, fluorescent/Mirror light fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connections with 1.5sqmm FRLS PVC insulated, copper coductor, single core cable and earthing etc. as required.
Make: Crompton/ Philips/Havells
8
-
-
Making hole50mm in Wall : Making hole through wall & providing PVC pipe (50mm) for installation of AC outdoor unit pipe & cable by demolishing brick work manually and the same as good finishing of wall by plastering etc as required.
8
-
-
Making hole for 250mm Exhaust fan:-Making hole for installation of exhaustfan size 250mm sweep by demolishing brick work manually and the same as good finishing of wall by plastering etc as required.
8
-
-
Shifting of AC Unit: Removing, Shifting & refixing of Air conditioning unit (upto 2ton) split type with existing out door unit stand and supply of copper tube 3m chord wire with insualtion white tape including gas refilling & other accessories as required for fixing at new loaction as directed by dept Engineering incharge.
8
-
-
METERING PANEL : Supply, erection & commissioning of wall/ suitable size hight angle base wall/floor mounting type of Energy Metering panel board fabricated with suitable size 14 SWG MS sheet/flat/angle duly painted and also suitable for Indoor installation and earthed consisting of the following as required: (a) Incomer: One chamber consisting of suitable size with mounting arrangements,supplying and fixing of 3no's 300A kitkat fuse cutout, nutral link, 1no of meter hylam, 1no of meter glass, RYB indication lamps, 4no's of fused terminal block etc.,
(b) Out going : 9 No's 32A Double Pole MCB,32A fuse carrier, meter hylam,meter glass,6sqmm inter connection wires (Make:L&T/Legrand/Simens) The above MCBs should be L&T/Legrand/Simens make and to be mounted in individual chambers consisting of suitable size with mounting arrangements and individual chamber locker system.
(c) Suitable size epoxy insulated colour coded Copper bus bars chamber along with Aluminium earth bus for entire system.
(d) Interconnection with suitable size insulated Copper link,spreder,provision of inscription labels etc.
(e) Removable of old EB Panel & refixing the exsisting EB Meters(9No's) and including outgoing wires end terminations.etc.,
(f) Suitable cable chamber with knock out holes and terminal blocks, interconnection materials etc.as required.
(g) Meter shifting charges payment to EB born by CLRI.(Work to be coordinated with TNEB if required)
1
-
-