Central Electrochemical Research Institute Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Central Electrochemical Research Institute - CECRI Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Nov 2023
Closing Date22 Nov 2023
Tender Amount₹ 10,10,101
Costs
EMD
₹ 20,202Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_CSIR_174144_1Bid Award Id
ViewTender No
CSIR CECRI NIT No 20/2023Tender Authority
Central Electrochemical Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation and Modification work in Continuous Electroplating area, EMF Division at CSIR-CECRI, Karaikudi
BOQ Items
In cement mortar
1.5
-
-
Removingold unnecessary clamps , angles ,curtain rods and other unwanted minor parts projected in walls & roofs. the rate inclusive of all lift and leads including necessary scaffolding as directed by the Engineer-in-charge.
1
-
-
Removing and placing the existing wooden furnitures and other movable items after executing the work including proper placing, cleaning wherever & whenever required as directed
1
-
-
Supplying chemical emulsion in sealed containers including delivery as specified.
-
-
-
Chlorpyriphos emulsifiable concentrate of 20%
5
-
-
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
-
-
-
Along the external wall below concrete or masonry apron us- ing chemical emulsion @ 2.25 litres per linear metre includ- ing drilling and plugging holes etc.:
-
-
-
With Chlorpyriphos E.C. 20% with 1% concentration
29
-
-
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 ce- ment : 2 coarse sand) to the full depth of the hole :
-
-
-
With Chlorpyriphos E.C. 20% with 1% concentration
49
-
-
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
23
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
-
-
-
Cement mortar 1:6 (1 cement : 6 coarse sand)
1
-
-
12 mm cement plaster of mix :
-
-
-
1:6 (1 cement: 6 coarse sand)
9
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
For fixed portion
-
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron)
58
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
-
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron)
10
-
-
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc.
-
-
-
After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in- Charge. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds
-
-
-
Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
-
-
-
Using R3 series with frame (55mm & above) x (40mm & above) & sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every panel along with multi- point locking system (Height upto 1.8m).
11
-
-
Providing and fixing glazing in UPVC window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. With colour glass panes of 4.0 mm thickness
8.5
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
-
-
-
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
7.2
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
-
-
-
Second class teak wood
0.1
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
150x10 mm
6
-
-
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 150mm
8
-
-
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
4
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
-
-
-
Twin rubber stopper
4
-
-
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
-
-
-
Upto 5mm depth and 5 mm width
16.3
-
-
French spirit polishing :
-
-
-
Two or more coats on new works including a coat of wood filler
18.5
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
-
-
-
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
8
-
-
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
15.3
-
-
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm
-
-
-
and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
-
-
-
GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
50
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
67
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
-
-
-
Water thinnable cement primer
67
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work
67
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
67
-
-
Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
4
-
-
Providing and fixing horizontal cassette roller blinds (Zebra) made of synthetic fabric of polyester /cotton with required pattern . Cassette mounting brackets shall support both the roller tube and the cassette. They must be capable of mounting inside, outside or to the ceiling, with the clutch on either right or left hand side of the roller. Cassette shall be installed to conceal the roller tube and mounting hardware. Cassette shall be made of approximately extruded aluminium and shall be painted with a high quality baked enamel finish, or finished with an anodized finish. Size of cassette depends on the size of blind. Cassette shall be able to accommodate a coordinated fabric insert and as directed by the Engineer-in-charge.
8
-
-
Providing and fixing 9 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with Non -decorative lamination on both sides
6
-
-
Supplying and fixing etching sticker for glass doors/ winows /glass partition including required design as directed by the Engineer-in-chage.
6
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
22
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
45
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
200
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
35
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
10
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
30
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
10
-
-
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
10
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
2 Pair
20
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
45
-
-
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
-
-
-
75 mm X 75 mm X 60 mm deep
2
-
-
100 mm X 100 mm X 60 mm deep
2
-
-
150 mm X 75 mm X 60 mm deep
2
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
4
-
-
15/16 A switch
40
-
-
3 pin 5/6 A socket outlet
6
-
-
6 pin 15/16 A socket outlet
40
-
-
Telephone socket outlet
1
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
7
-
-
6 Module (200mmX75mm)
2
-
-
8 Module (125mmX125mm)
1
-
-
12 Module (200mmX150nnm)
9
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
5
-
-
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
20
-
-
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
20
-
-
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
8
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way , Double door
1
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
4 way (4 + 12), Double door
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
30
-
-
Double pole
1
-
-
Triple pole
2
-
-
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
10
-
-
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
3
-
-
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
-
-
-
For 4 way, Double door TPN MCBDB
2
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
15
-
-
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
0.25
-
-
Laying of one number PVC insulated and PVC sheathed! XLPE power cable of 1.1 KV grade of following size direct in ground in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
10
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm
5
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
-
-
-
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
3 X 35 sq. mm (28mm)
1
-
-
312 X 70 sq. mm (38mm)
2
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
3
-
-
4 Ft Industrial LED Batten: Supply of standard 4 feet industrial indoor 40W,4000 lumensLED batten having high efficiency, flicker free suitable for wall, surface and conduit mounting system with required accessories as required. Similar to Philips Endura LED Next Model No. BN308CLED40S-6500 or Equivalent as approved by department.
5
-
-
Raceway: Supply and fixing of 100 x 50 mm UPVC cable management complete system / raceway trunking along with all accessories as required in surface and carrying out the proposed electrification works and rerouting the existing sub main/circuit mains wirings in the raceway complete in all aspects as required as per site condition. Make : MK/ Legrand/Siemens or Eauivalent as approved by department.
8
-
-
Raceway: Supply and fixing of 50 x 50 mm UPVC complete cable management system / raceway trunking along with all accessories as required in surface and carrying out the proposed electrification works and rerouting the existing sub main/circuit mains wirings in the raceway complete in all aspects as required as per site condition. Make : MK/ Legrand/Siemens or Eauivalent as approved by department.
10
-
-
2x2 LED fitting: Supply and fixing recessed mounting 2x2 LED energy efficient fitting, 4200 lumens, around 40 watts,WW/WH along with suitable driver with ripple less than 5% for flicker/glare-free light in the existing false ceiling with required accessories such as chain/string for supporting the fittings firmly in the ceiling including interconnections as required. Similar to Philips Full Glow G6 Model No : RC380B LED 42S-6500/4000 G6 l60 W60 PSU OD or Equivalent as approved by department.
12
-
-
Square/Round LED down lighter : Supply and fixing recessed mounting Square Down lighter LED energy efficient fitting,1000 lumens, 10W, WW/WH glare-free light along with suitable driver in the existing false ceiling with required accessories for mounting the fittings firmly in the ceiling including interconnections as required. Similar to Philips Green LED Ultima Square/Round Model No : DN0978 LED 10S-6500PSU or Equivalent as approved by department.
3
-
-
12 W, VTPNDB with 100 A MCCB:- Supplying and fixing 12 way surface/ recess mounting, vertical type, 415 volts, TPN MCCB distribution board (with wire way/ cable end box) of sheet steel,dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, along with 100 amps TP 16/18 KA,MCCB with adjustable thermal magnetic O/L & S/C protection, Ics=100% Icu, with set of spreaders & Phase barriers as incomer, interconnection between incomer MCCB and bus bars as required . The VTPN DB shall be mounted on a adequate size angle/flat and grouted/ fixed (drilling,cutting welding painting etc) firmlyl or completely concealed in the existing wal as required as per site condition complete in all aspects. The above DB shall include the following'C' series, 10 kA MCB's in the out going circuits TP MCB-63A-02 Nos TP MCB-32A-03 Nos SP MCB-6-32A-21 Nos Blanking plates -As required.
1
-
-
Removing the existing TPN and SPN DB's including frames, SFU’s of all size and types, Fuse carriers, Main switches, circuit and point wirings,switch boards, power boards fan and light fittings /power fittings with Various size of cables , and other unused and worn-out electrical installations, cutting the L angle channels and other unwanted materials in the proposed lab area complete and returning the removed items to the departments stores or any such place within the institute area as directed by the engineer in charge as per site condition.