Bharat Sanchar Nigam Limited Tender
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Bharat Sanchar Nigam Limited - BSNL Tender
Telecommunication Services
Eprocure
Opening Date21 Aug 2024
Closing Date3 Sep 2024
Tender Amount₹ 18,95,479
Costs
EMD
₹ 37,910Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Ei Mtce Bts Site West Ba Chennai
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_205600_1Bid Award Id
ViewTender No
31/EEE/ED1/ChTD/2024-25 1st RecallTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
TENDER DOCUMENT FOR NIT31R1 for downloading DSC and Uploading
BOQ Items
b) 1.5 TR Split type AC units with Compressor under Warranty
240
-
-
Note:
1) The AMC is all inclusive and also requires periodical visits,cleaning etc as per maintenance schedule
2) Wherever the compressor carries warranty from the OEM/supplier, agency shall arrange on their own required action such as removal, transporting, documentation, pursual, reinstallation, gas charging, commissioning and all connected works on thier own cost. 3)For the period when the compressor is sent for warranty, agency shall arrange for running the unit with spare compressor, wherever neccessary
4) Delay on the part of OEM shall not be considered as a reason for keeping the AC non-operational.
5)Units under OEM/Supplier warranty shall be taken over after completion of one year warranty period
-
-
-
SUB-HEAD - II ( Repair maintenance of EMS other than AC)
-
-
-
Attending breakdown calls and recifying the faults within the time limit as prescribed in the specification by Supplying and fixing/laying the following materials/spares as per site requirement with suitable accessories i/c removing the faulty items /materials/spares, transportation of materials to site and fixing etc as reqd.
4 x 16 sq.mm size Al. Armoured XLPE UG cable in the following manner
-
-
-
Direct in ground
175
-
-
On surface of wall
125
-
-
In existing pipe
100
-
-
In loose looping
150
-
-
40mm dia HDPE pipe of 8 Kgf/cm2 in the following manner for cable protection
-
-
-
Direct in ground i/c excavation,refilling and making good the surface
150
-
-
On surface of wall with suitable size clamp
100
-
-
In bitumen/Cement concrete road i/c road cutting and plastering with cement
50
-
-
End termination with brass compression gland and aluminium lugs for 4x 16 sq.mm (28 mm) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
60
-
-
Overhead Servie connection arrnangement with 4 x 16 sq.mm size PVC insulated Al. conductor wire in the following manner
-
-
-
i. With 2 runs of stay wire and insulators
200
-
-
ii. In loose looping/existing pipe
100
-
-
40 mm dia 'B' class GI pipe with suitable accessories for supporting OH service connection arrangement by fixing on ground with suitable cement concrete
25
-
-
Straight through joint with heat shrinkable kit including ferrules and other jointing materials for 4x16 sq.mm size of PVC insulated and PVC sheathed/XLPE Al. conductor cable of 1.1 KV grade as required.(Make:-BSNL Approved make)
6
-
-
4 x 10 sq.mm PVC insulated copper wire for interconnections i/c making end termination with suitable size lugs
50
-
-
4 x 6 sq.mm PVC insulated copper wire for interconnections i/c making end termination with suitable size lugs
20
-
-
63 A Rewirable fuse cutout with base
50
-
-
Following rating isolator/MCBs in existing DB/Meter box
-
-
-
40 A,Double Pole Isolator
18
-
-
63A Four Pole Isolator
18
-
-
5 - 32 A 'C' Series Single Pole MCB
90
-
-
32 A TP MCB
18
-
-
Neutral/earth link in existing meter box/DB i/c making connections
36
-
-
SMC sheet outdoor type service connection board with IP-65 protection of size not less than 520 mm x 420 mm x 190 mm on existing MS angle iron/surface of wall (Make:- SINTEX or SS)
18
-
-
9 mm thick hylam sheet for meter board including cutting, drilling etc.
5
-
-
Attending and solving minor electrical issues at BTS sites with suitable tools i/c transportation etc.,
60
-
-
Attending and solving minor electrical issues at BTS sites i/c Coordination with TNEB authorities for replacement of energy meter/Cable termination at EB pillar/post with suitable tools i/c transportation etc.,
50
-
-
S/F of folowing size MS Angle arrangement suitable for fixing existing EB Meter box with necessary accessories etc as reqd.a)
-
-
-
40 mm x 5 mm MS flat
35
-
-
40 x 40 x 5mm MS Angle
75
-
-
Providing & Fixing GI Busbar Arrangement with the following items inside the Shelter for proper earthing including making holes , cutting , making connections etc as reqd. a) 25mm x 3mm GI Strip ( Approx Length - 300mm - 2 Nos)
b) Insulator - 2 Nos c) 10mm Bolts & Nuts - 6 Nos // All the above consists of // - 1 Job
20
-
-
S/L of 20 mm dia PVC Pipe for the protection of GI wire Earth wire i/c necessary accessories etc as reqd
60
-
-
P/F of 300 mm x 300mm size masoary enclosure cover for the existing earth pit to protect the earth pit from damage etc as reqd.
20
-
-
S/F of 3 No of 63 A HRC fuses in the existing 63 A SFU including removing the blown out fuses, fixing the new one , testing and commissioning etc as reqd.
10
-
-
S/F of PVC Blanking plate suitable for SPMCB slot in the existing DB , including checking of proper fitting etc as reqd
75
-
-
Supplying and fixing of 32 , 'C' curve Double pole MCB in the existing MCB DB complete with connections, testing and commissioning etc as required.
5
-
-
Supplying and fixing of SMC sheet junction box of size 320x260x165 mm on surface of wall for protection of 4-pole isolator i/c transportation etc., complete as required.
10
-
-
Supplying and fixing of 4 Way - SPN DB complete with connections, testing and commissioning etc as required.
7
-
-
Supplying and fixing of 32A, 'C' curve Four Pole MCB in the existing MCB DB complete with connections, testing and commissioning etc as required.
15
-
-
Providing and laying earth connection from earth electrode with 6 SWG GI wire in 15mm dia GI pipe from earth electrode including connection with GI thimble excavation and refilling as reqd
150
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess
for loop earthing along with existing surface/ recessed conduit/
submain wiring/ cable as required.
300
-
-
Rewinding of exhaust fan i/c dismantling,to & fro to workshop and refixing etc., complete as required.
10
-
-
Supplying , Installation Testing and commissioning of 300 mm sweep medium duty exhaust fan including making openings suitable for fixing 300mm exhaust fan, connections, testing, commissioning etc. as required. (Make: BSNL Approved make)
5
-
-
S/F the Metal clad 3 Pin 20A plug/socket with suitable prefabricated MS enclosure with 1 NO , 20 A C series SPMCB i/c making connections , testing and commissiong etc as redq
15
-
-
Providing and fixing 20A 2pole + earth metal clad plug for the existing W/T AC units i/c giving connections, testing and commissioning etc as reqd
20
-
-
Painting the Existing MS Frame structure with one coat i/c removing the rust etc as reqd
30
-
-
Providing and fixing the gel type synthetic sealing compound all around the existing W/T AC units (outer side of the shelter) i/c providing the necessary foam between the gap/ opening around the unit etc
30
-
-
S/L of 3 x 2.5 sq.mm size 1.1 KV grade Copper Armoured XLPE UG cable on the existing cable tray etc as reqd
25
-
-
End termination with brass compression gland and Copper lugs for 3x 2.5 sq.mm PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade
15
-
-
Supplying and fixing of SMC sheet junction box of size 530x450x175 mm on surface of wall for protection of 4 Way- TPNDB i/c transportation etc., complete as required. ( Model : GSJB-5345 )
10
-
-
Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
10
-
-
Supplying and Fixing of 3 phase, 4 Wire - Digital Energy meter inside the Meter Box i/c suitable bolt & nuts, giving connections , testing and commissioning etc reqd ( Make : L & T , Model : ER300P-Cat No.WR301BC6D20 )
3
-
-