Bharat Electronics Limited Tender
... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.
Bharat Electronics Limited - BEL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2025
Closing Date1 Mar 2025
Tender Amount₹ 29,36,971
Costs
EMD
₹ 29,369Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_BEL_96724_1Bid Award Id
ViewTender No
CHN/ES/4798/7469/24-25Tender Authority
Bharat Electronics Limited ViewPurchaser Address
-Website
http://http://www.bel-india.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 module (75mm x 75mm) box
15
-
-
... More
Providing and laying of cPVC (SDR11) pipes of 25 mm dia for AC condensate water drain outside building with fittings, support including core cutting in brick/ concrete wall as required and making surface good etc. complete
25
-
-
... More
Supply, erection, testing and commissioning of size 6.35 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
10
-
-
... More
Supplying and fixing of 63A, TP (Triple pole) MCB, 415 V, 10 kA, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as directed by EIC. (Ref Model: LEGRAND - 4086 61 )
4
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia size (IS approved make)
150
-
-
... More
Supplying & Laying of following size LT power cable with Copper conductor, XLPE/PVC insulation, PVC inner sheathed, armoured, extruded PVC outer sheathed, 1.1KV grade (2XFY) cable, confirming to IS:7098(part-1) & relevant standards with latest amendments including laying of the same in existing trenches/duct/pipe/ on the wall/ cable trays with suitable clamps as directed by EIC. 4C X 10 Sq mm size
100
-
-
... More
Supply, erection testing and commissioning of Aluminium flexible duct of 100mm dia with insulation all as specified and/or directed etc., complete
5
-
-
... More
Supply, installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system's indoor unit of 4 way Cassette type of capacity not less than 1.5TR (5.25 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, high lift drain pump, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
3
-
-
... More
Supplying and making end termination of 4C x 6 sqmm Copper Cable with Copper Lugs and gland at one end of cable as directed by EIC.
2
-
-
... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm dia size
30
-
-
... More
Supplying, Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
50
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq.mm
50
-
-
... More
Supply, erection, testing and commissioning of size 28.6 mm dia refrigerant grade copper piping of 18 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C
75
-
-
... More
PART - E ELECTRICAL WORKS
-
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp modular switch
2
-
-
... More
Supply, installation, testing & commissioning of digital microcontroller based 2TIMER DB made out of 1.5mm thick CRCA sheet steel enclosure powder coat painted for auto change over & sequential operation of 4Air conditioner systems as per preprogrammed time intervals. Controller shall be supplied with inbuilt RS 485/ethernet port for communication complete as directed by EIC. Please refer drawing for details
3
-
-
... More
Supplying & Laying of following size LT power cable with Copper conductor, XLPE/PVC insulation, PVC inner sheathed, armoured, extruded PVC outer sheathed, 1.1KV grade (2XFY) cable, confirming to IS:7098(part-1) & relevant standards with latest amendments including laying of the same in existing trenches/duct/pipe/ on the wall/ cable trays with suitable clamps as directed by EIC. 4C X 6 Sq mm
10
-
-
... More
Supply, erection, testing and commissioning of size 15.9 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete.Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
35
-
-
... More
Supply, erection, testing and commissioning of 100mm Dia. - Butterfly damper should constructed with not less than 0.8mm thick galvanized steel sheet, with single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely all as specified and/ or directed etc., complete
4
-
-
... More
Supplying and making end termination of 4C x 16 sqmm Copper Cable with Copper Lugs and gland at one end of cable as directed by EIC.
4
-
-
... More
Supply, erection, testing and commissioning of size 31.8 mm dia refrigerant grade copper piping of 18 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
5
-
-
... More
Supply, fabrication, installation, testing and commissioning of factory fabricated GI sheet metal ducts of 24 Guage (Birmingham Gauge) (0.63 mm) and zinc coating not less than 120 g/m2 in accordance with approved drawings including necessary hangers, rubber gaskets, rivets, flanges, scaffolding required for work, etc., all as specified and/or directed etc.,complete Note 1) The rate quoted for the GI ducting shall be including the cost of scaffolding, steel supports, nuts, bolts, etc. and the same will not be measured and paid separately. 2) The rate quoted for the GI ducting deemed to include the cost of MS/ GI slotted channel supports. The MS/ GI slotted channel supports provided for GI ducting will not be measured and paid separately.
35
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps modular switch
2
-
-
... More
Providing and laying of cPVC (SDR11) pipes of 25 mm dia, with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated FRP cloth/ glass cloth for condensate water drain from the AC indoor units to nearest drain point, fittings, support including core cutting in brick/ concrete wall as required and making surface good with adhesive materials like silicon sealant etc. complete
25
-
-
... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia size
50
-
-
... More
Supplying and fixing of following ways, Vertical type, 415 V, TPN MCB distribution board made of sheet steel, dust protected and duly powder painted, on surface/ recess complete with 250 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs and slot with screws for mounting MCCB incomer, including earthing etc. as directed by EIC. (but without MCBs and MCCB ) 8 way (MCCB+24) VTPN DB, IP-43 with Metal door
(Ref model: LEGRAND - 5077 47 )
1
-
-
... More
Excavation for cable trenches in normal soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering, levelling and disposal of surplus excavated soil as directed, within a lead of 50 metres etc
5
-
-
... More
Supply, fabrication, installation, testing and commissioning of site fabricated GI sheet metal ducts of 24 Guage (Birmingham Gauge) (0.63 mm) and zinc coating not less than 120 g/m2 in accordance with approved drawings including necessary hangers, rubber gaskets, rivets, flanges, scaffolding required for work, etc., all as specified and/or directed etc.,complete. Note 1) The rate quoted for the GI ducting shall be including the cost of scaffolding, steel supports, nuts, bolts, etc. and the same will not be measured and paid separately. 2) The rate quoted for the GI ducting deemed to include the cost of MS/ GI slotted channel supports. The MS/ GI slotted channel supports provided for GI ducting will not be measured and paid separately.
15
-
-
... More
Supply and fixing of Hand held Fire Extinguisher - DCP - 6 Kg capacity as per IS - 13849 / 14609, duly charged, with BIS/ISI mark, complete with accessories including placing at a suitable location with floor mounting type MS stand or mounting with suitable fixture on wall / column etc., all as specified and/or directed complete. The contractor has to furnish a copy of BIS/ISI certificate along with the extinguishers, complete in all respect.
6
-
-
... More
Supply, erection, testing and commissioning of size 19.1mm dia refrigerant grade copper piping of 18 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete.Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
25
-
-
... More
Supply, erection, testing and commissioning of size 9.5 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
50
-
-
... More
Supply, installation, testing and commissiong of inline type propeller fresh air fan of capacity not less than 200 CFM, pressure not less than 20 mm total SP with canvass/ flexible duct as required for connecting the inline fan to the fresh air intake duct including providing plenum if required for connecting the fresh air fan to the duct and providing filter, louvre, bird screen at the air intake point with necessary clamps, screws etc., all as specified and/or directed etc., complete
1
-
-
... More
Supply, erection, testing and commissioning of High Wall Mount type Split AC units of 2.0 TR capacity, 5 star rating Inverter type rotary / scroll compressor, aircooled condensing unit with copper cooling coil, fan motor and indoor unit complete with filter section, cooling coil of copper tubes with aluminium fins, with anti corrosive paint suitable for coastal application, electric motor, fans including initial charge of R410A/ R32 refrigerant and subsequent charge / tapping of refrigerant during testing / commissioning if any, etc. as required, including minor civil works like core cutting all as specified and / or directed etc.,complete. Quoted price shall include cost of wireless remote controller, cooling thermostat, wiring, control cabling and earthing. Unit shall be provided with auto clean mode, auto timer setting and as per specifications.
5
-
-
... More
PART - C FRESH AIR SYSTEM
-
-
-
... More
Supplying and fixing following rating and breaking capacity MCCB with thermomagnetic release, phase barriers and terminal spreaders in existing VTPN Distribution board, making connections, including accessories etc. as directed by EIC. TPN MCCB up to 100A, 16kA, (Ref Model: LEGRAND-4200 15)
1
-
-
... More
Supplying and fixing 20A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
3
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" with cover(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
1
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm dia size (IS approved make)
100
-
-
... More
PART - F FIRE EXTNGUISHER
-
-
-
... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
50
-
-
... More
Providing and laying of cPVC (SDR11) pipes of 32 mm dia, with 9 mm thick elastomeric nitrile rubber tubular insulation for condensate water drain inside building from the AC indoor units to nearest drain point, fittings, support including core cutting in brick/ concrete wall as required and making surface good etc. complete
60
-
-
... More
System lumens :- Not less than 1200 lumens
-
-
-
... More
Supply, installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system's indoor unit of 4 way Cassette type of capacity not less than 1.0TR (3.5 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, high lift drain pump, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
1
-
-
... More
Supplying and fixing of 25 mm X 5 mm G.I strip on surface as strip earth electrode by providing suitable fixing acessories, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
50
-
-
... More
PART - B REFRIGERANT AND DRAIN PIPING FOR AC
-
-
-
... More
Supply, installation, testing and commissioning of a mutifunctional compact centralized Intellegent self Programmable controller. It shall be able to control minimum 32 indoor units. The controller shall have wide screen user friendly colour LED/ LCD display and can be wired by a non polar 2 wire transmission cable to a distance of 1 km away from indoor unit including necessary fixing arrangment to the desiared location and necessary control wiring from all indoor units to CIRTC and from all out door units to CIRTC and Software and hardware required to operate from end user system and povide MODBUS/ BACNET OUTPUT for IBMS integration with IP RS 485 compactability. The external wiring and inside wiring shall run suitable size conduit all as specified and / or directed etc., complete.
1
-
-
... More
Supply, erection, testing and commissioning of size 25.4 mm dia refrigerant grade copper piping of 18 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
5
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 module (125mm x 75mm) box
1
-
-
... More
PART A - VRF/ VRV AC WORKS
-
-
-
... More
Supply, erection, testing and commissioning of size 22.2mm dia refrigerant grade copper piping of 18 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
5
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral MCB.
2
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade at one end as required. 3½ X 35 sq. mm (32mm)
2
-
-
... More
Supply, installation, testing and commissiong of inline type propeller fresh air fan of capacity not less than 150 CFM, pressure not less than 20 mm total SP with canvass/ flexible duct as required for connecting the inline fan to the fresh air intake duct including providing plenum if required for connecting the fresh air fan to the duct and providing filter, louvre, bird screen at the air intake point with necessary clamps, screws etc., all as specified and/or directed etc., complete
1
-
-
... More
Supplying & Laying of following size LT power cable with Aluminium conductor, XLPE/PVC insulation, PVC inner sheathed, armoured, extruded PVC outer sheathed, 1.1KV grade (A2XFY) cable, confirming to IS:7098(part-1) & relevant standards with latest amendments, including laying of the same in existing trenches/duct/pipe/ on the wall/ cable trays with suitable clamps as directed by EIC. 3.5C X 35 Sq mm size.
100
-
-
... More
Supply, installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system's outdoor unit of capacity not less than 14HP, equiped with highly efficient hermetic scroll compressor or twin rotary type compressors, equipped with inverter control capable of changing the speed in accordance to the cooling load requirement, heat exchanger, low noise condenser fan, outdoor unit multiple connecting unit, including first charge of R410a refrigerant & oil, etc. The inverter shall be IGBT type to be efficient and quiet operation. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation. The quoted price shall include MS angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads all as specified and / or directed etc., complete. Note: The quoted rate for this item deemed to include the cost for necessary hardware, software, gateway, interface, controller etc.
2
-
-
... More
Providing and laying of cPVC (SDR11) pipes of 32 mm dia without insulation for condensate water drain outside building from the AC indoor units to nearest drain point, fittings, support including core cutting in brick/ concrete wall as required and making surface good etc. complete
10
-
-
... More
Supplying and fixing 20 mm dia GI flexible pipe along with all ancillaries and accessories like coupler etc. as required
5
-
-
... More
PART - D HI WALL SPLIT AC SYSTEM
-
-
-
... More
Supply, installation, testing and commissiong of inline type propeller fresh air fan of capacity not less than 380 CFM, pressure not less than 20 mm total SP with canvass/ flexible duct as required for connecting the inline fan to the fresh air intake duct including providing plenum if required for connecting the fresh air fan to the duct and providing filter, louvre, bird screen at the air intake point with necessary clamps, screws etc., all as specified and/or directed etc., complete
1
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (8 + 12), TPNDB Double door
2
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
24
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 module (100mm x 75mm) box
3
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp modular socket outlet
11
-
-
... More
Supply and laying of Communication / Control cable connecting the Indoor units / Outdoor units / Controller of suitable size as recommended by the OEM. The external communication / control cabling shall be run in MS conduit and inside building control cabling shall be run in PVC conduit including all clamps, screws, fittings, supporting items etc., all as specified and/or directed etc., complete. Note: 1) The cost for MS and PVC conduit shall be measured and paid seperately under relevant item of SOQR
400
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole MCB.
4
-
-
... More
Supply, erection, testing and commissioning of size 12.7 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation with factory laminated glass cloth, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between the outdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR. 2)The supports for refrigerant Cu pipe shall be provided at 500 mm C/C.
85
-
-
... More
Supplying and making end termination of 4C x 10 sqmm Copper Cable with tinned Copper Lugs and gland at one end of cable as directed by EIC.
20
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet modular
2
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray with cover (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thicknes
10
-
-
... More
Supply, erection, testing and commissioning of refrigerant grade copper piping between indoor and outdoor units of suitable size (both suction and discharge piping will be treated as one unit and will not be measured separately),Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated with glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil, joints, fittings, accessories, core cutting in brick/ concrete wall as required and making surface good, supports etc. suitable for upto 2.0 TR capacity High wall split AC unit
60
-
-
... More
Supply, installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system's indoor unit of 4 way Cassette type of capacity not less than 2.0TR (7.0 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, high lift drain pump, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
5
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 6 sq.mm
100
-
-
... More
Supply, installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system's indoor unit of 4 way Cassette type of capacity not less than 2.5TR (8.75 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, high lift drain pump, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
1
-
-
... More
Supplying of non-metalic IP-65 rated 20A, 230V, 2P+E socket outlet along with suitable Plug top & 20A, 10KA-Curve SPN MCB, including suitable non corrosive enclosure and fixing of the same on surface or in recess, with complete accessories, connections, testing and commissioning etc. as required. (Ref make: Scame)
10
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" with cover(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness
2
-
-
... More
Supply, installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system's indoor unit of 4 way Cassette type of capacity not less than 3TR (10.5 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, high lift drain pump, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
1
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq.mm
200
-
-
... More
Supplying of non-metalic IP-65 rated 63A, 415V, TPN socket outlet along with suitable Plug top & 63A, 10KA-Curve TPN MCB, including suitable non corrosive enclosure and fixing of the same on surface or in recess, with complete accessories, connections, testing and commissioning etc. as required. (Ref make: Scame)
2
-
-
... More
Supply, erection, testing and commissioning of 150mm Dia. - Butterfly damper should constructed with not less than 0.8mm thick galvanized steel sheet, with single flap, necessary stopper, flanges for fastening on to the duct surface and with grooves for clamping the flexible ducts securely all as specified and/ or directed etc., complete
7
-
-
... More
Supply and fixing of Hand held Carbon dioxide type fire extinguisher of 4.5 kg capacity as per IS - 2878, duly charged, with BIS/ISI mark, complete with accessories including placing at a suitable location with floor mounting type MS stand or mounting with suitable fixture on wall / column etc., all as specified and/or directed complete. The contractor has to furnish a copy of BIS/ISI certificate and Controller of Explosive Certificate along with the extinguishers, complete in all respect.
4
-
-
Evaluation Notes How It Works ?