Airports Authority Of India Tender

... More
Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Airports Authority Of India - AAI Tender

Services
Electrical and Electronics
Electrical Works
GEM
Opening Date12 Feb 2025
Closing Date5 Mar 2025
Tender Amount₹ 7,51,47,848 
Notes
Download

AI Insights

Bid Capacity
... View More
The bid capacity required includes a financial capacity of a minimum average annual turnover of 113 Lakh over 3 years. The experiential capacity requires 7 years of experience in similar services, with specific project cost criteria that can be represented by the following formulas: 1. EC = 3SC, where each SC costs ≥ 40% of the estimated cost. 2. EC = 2SC, where each SC costs ≥ 50% of the estimated cost. 3. EC = 1SC, where SC costs ≥ 80% of the estimated cost. However, a precise numerical value for the experiential capacity in terms of cost cannot be calculated without a specific estimated cost for the services.
Technical Capacity
... View More
The bidder must have 7 years of experience in providing similar type of services to any Central / State Govt Organization / PSU. The bidder should have successfully executed/completed similar services with specific requirements, including: 1. Three similar completed services costing not less than 40% of the estimated cost; 2. Two similar completed services costing not less than 50% of the estimated cost; 3. One similar completed service costing not less than 80% of the estimated cost. Additionally, the bidder needs to upload copies of relevant contracts/orders to support their experience. Micro or Small Enterprises are exempt from the experience criteria.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Monitoring and Maintenance of Water Supply Installations at ATS Complex comprising of Water Supply Pumps, RO Plant, LT Panels etc., at Pump House of ATS Complex, Including Operation of Elevators at ATS Complex as per the Direction of Engineer-In-Charge (As per Annexure 'A3' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with ATS Switch Room and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.

24

-

-

... More
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at at AAI Operational Offices comprising of Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., at RHQ SR Operational Offices (As per Annexure 'A4' - List of Inventories) on General Duty Basis (8 Hours of Duty of Time as decided by Engineer-In-Charge), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with Chennai Airport Admin Power House Cum Substation and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations etc., on all days as specified and as directed by Engineer-In-Charge as required.

24

-

-

... More
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at MSSR Porur Power House Cum Sub-Station/MSSR Building comprising of 11 KV VCB Panels (03 Nos.), 2 Nos. of 250 KVA 11 KV/433 Volt Transformers, 2 Nos. of 160 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of Elevator, AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A7' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with TANGEDCO and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/ Repairs/ Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/ satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/ Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.

24

-

-

... More
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at WT Station Mugalivakkam Power House Cum Sub-Station comprising of 11 KV VCB Panels (03 Nos.), 2 Nos. of 250 KVA 11 KV/433 V Transformers, 2 Nos. of 62.5 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A8' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with TANGEDCO and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.

24

-

-

... More
Monitoring and Maintenance of Utility Services/Internal and External Electrical Services at ASR/MSSR Power House Cum Sub-Station/MSSR Building in Operational Area of Chennai Airport comprising of 11 KV VCB Panels (07 Nos.), 2 Nos. of 500 KVA 11 KV/433 Volt Transformers, 2 Nos. of 320 KVA LT DG Sets, LT Panels, associated Earthing System of Utilities, Light Fittings, Power Points, Circuit/Submain Wiring, DBs, LT Panels, Aviation Obstruction Lights, Lightning Arrestors, Street Light Poles/External Lights, Signage etc., Including Operation of AC Units, Water Supply Installations and Water Softening/Treatment Units (As per Annexure 'A10' - List of Inventories) for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift), Monitoring, Control and General Maintenance for 100% Serviceability including Co-ordination with ATS SS/Old Airport Power House/Remote Bays Power House and i/c providing consumable material like cotton waste, oil, grease & other sundry material required for cleaning etc., attending minor faults of Equipments/Repairs/Replacement of defective components with AAI Supplied New Components, ensuring 100% Serviceability/satisfactory working condition of the Systems, Routine and General Preventive Maintenance on Daily/Weekly/Monthly/Quarterly/ Half Yearly/Yearly Basis as per Standard Manufacturers' Practices and as per Techno Commercial Specifications (TCS), Maintenance of Records and Log Books and reporting as and when required, complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required. complete Upkeeping of the Installations, on all days including Sundays & Holidays as specified and as directed by Engineer-In-Charge as required.

24

-

-

... More
Providing Supervisory Engineering Services for All E&M Installations Covering Item 1 to 10 as above including Monitoring/Control/Co-ordination/Maintenance of Utility Services/Internal and External Electrical Services for round the Clock 24X7 Basis (Three Shift Basis - 8 Hours For One Shift)/General Duty (Timing as decided by EIC) , Maintenance of Records and Log Books and reporting as and when required, on all days as specified and as directed by Engineer-In-Charge as required.

24

-

-

... More
SH: II A ISC of HT Panels and LT ACBs of Power Supply Installations.

-

-

-

... More
Overhauling and Servicing of (400 - 1250) Amp 11 KV HT VCBs by Deploying Authorised Service Personnel of Manufacturer/Service Dealer/ Specialised Agency experienced in similar nature of work, provided at Various Power Houses/ Substations including drawing out of the VCB, opening the same, Inspection, Servicing, Cleaning of Contact Surfaces, Overhauling of Operating Mechanism, Lubrication of Moving Parts, Cleaning of CTs, PTs, Busbars and Chambers, Checking of Busbars and bus links, Replacement of Gasket of Panel, Checking of Electrical and Mechanical Operation, measuring of Contact Resistance, Checking of IR values, Testing of ON OFF Time, replacement of minor defective spares supplied by AAI (excluding supply of spares), Testing and Commissioning etc., as required. ISC of VCBs(i. ATS Complex - 6 Nos VCBs (Make:Kirloskar), ii. New ASR MSSR - 7 Nos VCBs (Make: CG), iii. MSSR Porur - 3 Nos VCBs (Make: Jyothi), iv. WT Station - 3 Nos VCBs (Make: CG))

-

-

-

... More
First Year

19

-

-

... More
Second Year

19

-

-

... More
Overhauling and Servicing of following capacity Trip Circuit Battery Charging Unit by Deploying Authorised Service Personnel of Manufacturer/ Service Dealer/ Specialised agency experienced in similar nature of work, provided at Various Power Houses/ Substations including Inspection, Servicing, Cleaning of Charger, Checking of Charger Circuit (Control and Power Circuit) including Instruments/ Relays/ Meters/ Transformers/ Rectifiers/ Filters, attending faults, Replacement of Defective Components (Excluding Cost of Spares), Checking of Batteries, Terminals, Checking of Operation, Testing and Commissioning etc., as required.

-

-

-

... More
Less than 30V battery charger

-

-

-

... More
First Year

8

-

-

... More
Second Year

8

-

-

... More
Inspection/Overhauling/Servicing of ACBs of L&T/ GE/ C&S Make of Various Capacities provided in the various LT Panels at Various Power Houses/ SSs by Deploying Authorised Service Personnel of Manufacturer/ Service Dealer/ Specialised Agencies experienced in Servicing of ACBs including cleaning of ACBs, opening the same, inspection, servicing, cleaning of contact surfaces, arc chutes, overhauling of operating mechanism, lubrication of moving parts, Checking of UV Coils, Trip Circuits, Checking of Control Circuits, replacement of minor defective spares supplied by AAI (excluding supply of spares), testing and commissioning etc., as required. (i.ATS Complex -41 Nos, ii.New ASR MSSR - 3 Nos)

-

-

-

... More
First Year

3

-

-

... More
Second Year

44

-

-

... More
Testing of Releases provided in various ACBs in various LT Panels, Testing of Tripping, Timing, etc., i/c adjustment of Settings if required at site by Secondary Injection Test as required. (i.ATS Complex -41 Nos, ii.New ASR MSSR - 3 Nos)

-

-

-

... More
First Year

3

-

-

... More
Second Year

44

-

-

... More
SH: II B Calibration of Relays and Testing of CTs.

-

-

-

... More
Calibration of Relays [(Electro-Mechanical/ Static/ Digital/ Microprocessor Based Relays)-(O/C and E/F)/] provided in various HV/LV Panels, Testing of Insulation Values, Pick-up Value, Timing, Burden, etc., i/c adjustment of Settings if required at site, Relay Co-ordination with immediate Up and Down Circuit etc., as required, conforming to IS 9124 - 1979 by Secondary Injection Test as required.

-

-

-

... More
First Year

15

-

-

... More
Second Year

15

-

-

... More
Calibration of Auxillary Relays/Master Trip Relay provided in various HV/LV Panels, Testing of Insulation values, Pick-up Value, Drop Off, Burden etc., as required, conforming to IS 9124 - 1979 by Secondary Injection Test as required.

-

-

-

... More
First Year

45

-

-

... More
Second Year

45

-

-

... More
Testing of 11 KV CTs (3 Nos. of Current Rating of Upto 400 Amps associated with Relays (OC/EF/Master) provided in various HV Panels, Tesing of Polarity, Ratio, Insulation values, Testing of Ammeter connected in the Panel, Marking of available CT Ratio, Checking of Trip Circuit and Breaker Operation/Tripping etc., as required, conforming to IS 9124 - 1979 by Primary Injection Test (Maximum upto 50% of Rating of CTs-Testing at 25% and 50% of Original Rating) as required.

-

-

-

... More
First Year

15

-

-

... More
Second Year

15

-

-

... More
SH II C : Filtration of Transformer Oil and Servicing of OLTCs.

-

-

-

... More
Filtration of Transformer Oil of following Equipments conforming to IS 6792/72 and IS 1866 as required with up to date amendments, including transporting Filtration Plant and BDV Test Kit, Replacement of Silica Gel, Acidity Testing of Oil at Chemical Testing Lab, Submission of Reports, Checking of Cable Tightness, Gasketting of Cable End Boxes etc. as required (including oil top up if required which will be supplied by AAI).

-

-

-

... More
ATS COMPLEX SUBSTATION 2 MVA 11KV/433V Transformer Approx Oil Qty in ltrs 2130.00

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
MSSR PORUR SUBSTATION 250 KVA 11KV/433V Transformer Approx Oil Qty in ltrs 370.00

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
WT STATION MUGALIVAKKAM 250 KVA 11KV/433V Transformer Approx Oil Qty in ltrs 320.00

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
Supply of Transformer Oil conforming to IS 335/1983 for topping up of oil for Transformer during filtration of Oil and for replacement of Oil for the Transformers.

-

-

-

... More
First Year

300

-

-

... More
Second Year

300

-

-

... More
Testing of Power Transformer of following rating 11 / 0.433 KV i/c testing of Insulation resistance, Magnetising current, winding resistance with micro-Ohm meter and Magnetic balance, etc., as required.

-

-

-

... More
ATS COMPLEX SUBSTATION 2 MVA 11KV/433V Transformer

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
MSSR PORUR SUBSTATION 250 KVA 11KV/433V Transformer

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
ELDIS RADAR SUBSTATION 400KVA 11KV/433V Transformer

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
WT STATION MUGALIVAKKAM 250 KVA 11KV/433V Transformer

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
Providing and Fixing Glass Cover, Rubber Beading for Marshelling Boxes of Transformers as required.

-

-

-

... More
First Year

1

-

-

... More
Second Year

1

-

-

... More
Servicing of Voltamp Make OLTC available in 2 MVA, 11 KV/433 V Transformer at ATS Complex Power House by OEM/OEMs' Authorised Service Dealer completely including removing of Oil from the tank, flushing out of deposits, cleaning of contacts, checking and tightening of contacts and fasteners, checking of transient resistance, topping up of New oil/Filtration of Oil through oil Filtration machine (excluding supply of oil), lubricating the mechanism, replacing top cover gasket, Checking of RTCC Panel, checking of operation electrically and manually (local & remote operation), replacement of minor defective spares supplied by AAI (excluding supply of spares), etc., as required.

-

-

-

... More
First Year

2

-

-

... More
Second Year

2

-

-

... More
SH II D : CMC of Active Harmonic Filter

-

-

-

... More
Comprehensive Annual Maintenance Contract of Active Harmonic Filters of Capapcity 35A (by OEM / authorized dealer of OEM) including replacement of all spares, consumables, manpower required for trouble shooting arrangement of all tools and plants, routine preventive and breakdown maintenance etc. as required as per good Engineering practice for maintaining the system in operational and serviceable state. (Location: Porur)

-

-

-

... More
First Year

4

-

-

... More
Second Year

4

-

-

... More
SH-III Servicing of E & M Installations.

-

-

-

... More
Lifting of Submersible Pumps of various capacities from the existing Bore Well/Well and reinstalling the Submersible Pumps in the existing bore well / well (After servicing/ repairing both are exclusive) complete as required.

3

-

-

... More
Rewinding of 1 No. 1.5 / 2 HP borewell / submersible / Monoblock motor pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Rewinding of 1 No. 3HP borewell / submersible pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Rewinding of 1 No. 5HP submersible / monoblock motor pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Rewinding of 1 No.7.5 HP submersible pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Rewinding of 1 No. 10 HP borewell / submersible pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Servicing of 1 No. 1.5 / 2 HP borewell / submersible / Monoblock motor pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Servicing of 1 No. 3HP borewell / submersible pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Servicing of 1 No. 5HP submersible / monoblock motor pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Servicing of 1 No.7.5 HP submersible pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Servicing of 1 No. 10 HP borewell / submersible pumpset, including replacement of damaged parts such as inlet base, bushes, thrust bearing set, neck rings etc, including reassembling, painting, testing, transpotation etc as required.

1

-

-

... More
Comprehensive Annual Maintenance Contract of 2 Nos 400 LPH RO Plant inclusive of monthly servicing, attending faults/ breakdowns and taking rectification action as and when required, maintaining the serviceability / satisfactory working condition of the plants, adding antiscalant chemicals to avoid scaling of pipelines as and when required, replacement of prefilter cattridge once in three months, including sand filter ,maintaining the required taste and required TDS level (30 to 120) including providing test reports for the same and submission of quarterly water test report from Govt. / ISO certificate recongnised laboratory, etc as required. (excluding Membrane).

24

-

-

... More
Supply of RO membrane for RO plant of 400LPH capacity (Make CSM , model RE 4040 -BN or its equivalent).

4

-

-

... More
Annual Maintenance Contract of Fire Hydrant System consisting of Jockey/ Electrical/ Diesel pumps with associated Electro Mechanical installations at ATS Complex, carrying out regular monthly checks required, attending breakdowns as and when required, carrying out B checks for Engines excluding supply of B check spares and other spares as required. (Service visits for jockey pump, electrical fire pump and Diesel driven fire pump shall be carried through OEM (M/s.Kirloskar) or OEM authorized).

24

-

-

... More
Repair & Rewinding of 1400/1200 mm Sweep Ceiling fan i/c replacement of spares as required.

5

-

-

... More
Repair & Rewinding of all capacities of exhaust fan i/c replacement of spares as required.

20

-

-

... More
Repair & Rewinding of high speed heavy duty pedestal / wall mounting fan i/c replacement of spares / bearings etc. as required.

5

-

-

... More
Maintenance of Conventional/ Microprocessor Based Fire Alarm System [FAS] including all Associated Accessories and Auto Dialer of all FAS Types/ Models/ Make installed at following Locations including Repairs and Maintenance, attending Faults of Systems, Replacement of Defective Components with AAI Supplied New Components, ensuring 100% Serviceability/ Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/ Quarterly/ Half yearly/ Yearly Basis as per Standard Manufacturers' Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations [FAS], as specified and as directed by Engineer-In-Charge as required.

-

-

-

... More
Localizer 07 (Two Zone - Make : Ravel)

24

-

-

... More
Localizer 25 (Two Zone - Make : Ravel)

24

-

-

... More
GP 07 (Two Zone - Make : Ravel)

24

-

-

... More
GP 25 (Two Zone - Make : Ravel)

24

-

-

... More
SMR 1 (Two Zone - Make : Ravel)

24

-

-

... More
SMR 2 (Two Zone - Make : Ravel)

24

-

-

... More
DVOR 12 (Two Zone - Make : Ravel)

24

-

-

... More
Remote Receiver Station (Two Zone - Make : Ravel)

24

-

-

... More
Maintenance of Addressable Type Fire Alarm System [FAS] (by OEM/ authorized dealer of OEM) including all associated accessories, fire dampers at AHUs and Auto Dialer of all FAS Types/Models/Make installed at following Locations including programming, repairs and maintenance, attending Faults of Systems, replacement of defective components with AAI supplied new components, ensuring 100% Serviceability/Satisfactory Working Condition of FAS, Routine and General Preventive Maintenance on Monthly/Quarterly/Half yearly/Yearly Basis as per Standard Manufacturers' Practices, Break-Down Maintenance, Maintenance of Records/Service Reports and Reporting as and when required, complete Up-keeping of the Installations [FAS], as specified and as directed by Engineer-In-Charge as required.

-

-

-

... More
ATS Complex (8 Loop, Make:EdwardsS)

24

-

-

... More
Operational Offices Admin Budilding(NAD) (Four Loop - Make: EdwardsS)

24

-

-

... More
DVOR 07 (Single Loop - Make : EdwardsS)

24

-

-

... More
New ASR/MSSR (Two Loop - Make : EdwardsS)

24

-

-

... More
MSSR Porur (Two Loop - Make : EdwardsS)

24

-

-

... More
WT Station (Single Loop-Make:EdwardsS)

24

-

-

... More
Supply of UL Listed Intellegent Addressable type Optical Smoke cum Heat Detector complete with all accessories like base, base box etc., to be installed under/above false ceiling - roof/concealed space etc., including interconnecting with loop cable complete as required (suitable for Edwards fire alarm system).

30

-

-

... More
Supply of UL Listed Intellegent Addressable type Optical Heat Detector complete with all accessories like base, base box etc., to be installed under/above false ceiling - roof/concealed space etc., including interconnecting with loop cable complete as required (suitable for Edwards fire alarm system)..

5

-

-

... More
Supply and fixing of UL Listed Addressable Hooter cum Strobe complete with address switch including base plate, box, necessary accessories etc., as required (suitable for Edwardss fire alarm system).

5

-

-

... More
Supply of UL Listed Addressable type Manual Call Point (Pull Station Type) complete with Input Module, Push Botton, enclosed in box with provision for cable or conduit coupling, painted as required (suitable for Edwardss fire alarm system).

5

-

-

... More
Supply of UL Listed Intelligent addressable Control Relay Module suitable for Single output activation complete with termination etc., as required (suitable for Edwards fire alarm system).

5

-

-

... More
Supply of UL Listed Intelligent addressable Hooter Control Module suitable for Single output activation complete with termination etc. as required (suitable for Edwardss fire alarm system).

5

-

-

... More
Supply of UL Listed Addressable Loop/Fault Isolator with base with termination etc. as required (suitable for Edwardss fire alarm system).

2

-

-

... More
Supply of UL Listed Response Indicators for getting fire indications of detectors installed above false ceiling/below false flooring area as required (suitable for Edwards fire alarm system).

5

-

-

... More
Supply of UL Listed Intelligent addressable Input Relay Module suitable for Single output activation complete with termination etc., as required (suitable for Edwards fire alarm system).

1

-

-

... More
Supply of conventional smoke detectors suitable for Ravel

10

-

-

... More
Supply of conventional MCP suitable for Ravel

5

-

-

... More
Supply of conventional hooters suitable for Ravel

5

-

-

... More
Supplying & laying of 2Cx1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required

200

-

-

... More
Supply and installation testing & comissioning of 230V operating control relay module (230V 24DC).

5

-

-

... More
Supply and installation testing & comissioning of 230V operating control relay module for shutter function.

5

-

-

... More
Supply and installation testing & commissioning of SMPS (230 nto 24VDC)

10

-

-

... More
SH III(B) : AMC of Automatic Sliding Door

-

-

-

... More
Annual Maintenanace contract of Automatic Sliding doors at Admin Building (1 No), Centre opening including Routine/preventive quarterly maintenance, attending Break down Maintenanace , attending Minor & Major repair works,ensuring 100% serviceability and satisfactory working condition as per standard manufacturers practices and documentation of service/ complaints/PMI Checks etc as required ( spares excluded).

-

-

-

... More
First year

4

-

-

... More
Second Year

4

-

-

... More
SH-IV: Annual Rate Contract for Internal Electrical works

-

-

-

... More
Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

10

-

-

... More
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

-

-

-

... More
Group C

20

-

-

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.

10

-

-

... More
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.

10

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

10

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

20

-

-

... More
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.

-

-

-

... More
2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire

50

-

-

... More
2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire

50

-

-

... More
2 X 4 sq.mm + 1 X 4 sq.mm earth wire

50

-

-

... More
2 X 6 sq.mm + 1 X 6 sq.mm earth wire

50

-

-

... More
Supply Items

-

-

-

... More
Supply of following size/ modules, PVC box along with modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
3 Module

50

-

-

... More
6 Module

30

-

-

... More
8 Module

5

-

-

... More
12 Module

1

-

-

... More
Supply of following sizes of steel conduit as per IS 9537 as and when required.

-

-

-

50

-

-

100

-

-

... More
Supply of following sizes of medium class PVC conduit as per IS 9537 as and when required.

-

-

-

50

-

-

50

-

-

... More
Supply of following sizes of medium class PVC Casing and Caping as per IS 14927 as and when required.

-

-

-

100

-

-

100

-

-

... More
Supply of 1.1KV grade following sizes of FRLSH PVC insulated single core copper conductor cable as per IS 694 as and when required.

-

-

-

... More
1.5 sq. mm

300

-

-

... More
2.5 sq. mm

300

-

-

... More
4 sq. mm

100

-

-

... More
6 sq. mm

100

-

-

... More
Supply of following modular switch / socket (Make: as per list of approved makes as and when required).

-

-

-

... More
5/6 Amps switch

50

-

-

... More
15/16 Amps switch

75

-

-

... More
3 pin 5/6 Amps socket outlet

50

-

-

... More
6 pin 15/16 Amps socket outlet

75

-

-

... More
Supply of TPN 8 Way (8+24) MCB DB IP 43 double door vertical type 3 phase (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of TPN 4 Way (8+12) MCB DB IP 43 double door vertical type 3 phase (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of SPN 8 Way MCB DB double door (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of SPN 6 Way MCB DB double door (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of SPN 4 Way MCB DB double door (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of 40A FP MCB 415 volts, Four pole MCB, C curve (Make: as per list of approved makes as and when required).

10

-

-

... More
Supply of 63A FP MCB 415 volts, Four pole MCB, C curve (Make: as per list of approved makes as and when required).

5

-

-

... More
Supply of 40A FP RCCB, 300mA 415 volts, C curve (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of 63A FP RCCB, 300 mA 415 volts, C curve (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of 40A FP RCCB, 100mA 415 volts, C curve (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of 63A FP RCCB, 100 mA 415 volts, C curve (Make: as per list of approved makes as and when required).

2

-

-

... More
Supply of SP MCB 5 amps to 32 amps rating, 240/415 volts, "C" curve. (Make: as per list of approved makes as and when required).

30

-

-

... More
Supply of DP MCB 5 amps to 32 amps rating, 240/415 volts, "C" curve (Make: as per list of approved makes as and when required).

20

-

-

... More
Supply of TP MCB 5 amps to 32 amps rating, 240/415 volts, "C" curve (Make: as per list of approved makes as and when required).

5

-

-

... More
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

5

-

-

... More
Providing illumination with standard couloured serial lamps sets (Containing minimum 40 Nos of lamps per set & minimum 1500 sets) for one occassion of minimum 48 hrs on the ADMN building,ATS and other ancillary building and trees as directed by the Engineer-In - Charge.

4

-

-

... More
Providing illumination with multicolour LED colour wash flood light with minimum of 125 wall washers for one occasion of minimum 48 hrs with required cables and all accessories to illuminate the fasia of the buildings as directed by the Engineer -In- Charge.

4

-

-

... More
SH-V-A : Cabling Works

-

-

-

... More
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 35 sq. mm

50

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

50

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

200

-

-

... More
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ HDPE / METAL pipe as required.

-

-

-

... More
Upto 35 sq. mm

50

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

200

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

300

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.

-

-

-

... More
Upto 35 sq. mm

50

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

100

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

100

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

25

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

25

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25x3mm MS flat clamp)

25

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

25

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

50

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

50

-

-

... More
Above 95 sq.mm and upto 185 sq.mm (clamped with 25x3mm MS flat clamp)

100

-

-

... More
Above 185 sq.mm and upto 400 sq.mm (clamped with 40x3mm MS flat clamp)

100

-

-

... More
Supplying and making cable route marker with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

5

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 120 sq.mm and upto 400 sq.mm

25

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/HDPE / METAL pipe as required. Above 120 sq.mm and upto 400 sq.mm

150

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm

50

-

-

... More
RETRIEVAL OF CABLES

-

-

-

... More
Retrieval of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size upto 400 Sqmm from ground including excavation and refilling the trench etc.. as required.

50

-

-

... More
Retrieval of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size upto 400 Sqmm from the existing RCC/ HUME/HDPE / STONEWARE/ METAL/ GI PIPES/ Duct/ TRAY/ TERRACE etc., as required.

200

-

-

... More
Retrieval of one number PVC/XLPE insulated and PVC sheathed power cable of 11KV grade of size upto 300 Sqmm from ground including excavation and refilling the trench etc.. as required.

50

-

-

... More
Retrieval of one number PVC/XLPE insulated and PVC sheathed power cable of 11KV grade of size upto 300 Sqmm from the existing RCC/ HUME/ STONEWARE/ HDPE / METAL/ Duct/ GI Pipe etc., as required.

100

-

-

... More
Retrieval of one number PVC/XLPE insulated and PVC sheathed power cable of 1.1KV grade of size exceeding 120 sqmm but not exceedind upto 400 Sqmm from ground including excavation and relaying after fault rectification using same brick, fresh sand cushioning protective covering and refilling the trench etc.. as required.

200

-

-

... More
Retrieval of one number PVC/XLPE insulated and PVC sheathed power cable of 11KV grade of size exceeding 120 sqmm but not exceedind upto 300 Sqmm from ground including excavation and relaying after fault rectification using same brick, fresh sand cushioning protective covering and refilling the trench etc.. as required.

50

-

-

... More
Laying of one number PVC/XLPE insulated and PVC sheathed Power cable of 1.1KV grade of size exceeding 120 sqmm but not exceeding 400sqmm direct in ground including demolishing cement concrete/bituminous road, excavation of trench of upto 0.75 Mtr Depth refilling the trench making the surface to original finish with CC of 1:3:6 ratio on top (150 mm) etc. as required

25

-

-

... More
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 16 sq. mm (28mm)

2

-

-

... More
4 X 25 sq. mm (28mm)

4

-

-

... More
3½ X 35 sq. mm (32mm)

2

-

-

... More
3½ X50 sq. mm (35mm)

2

-

-

... More
3½ X 70 sq. mm (38mm)

2

-

-

... More
3½ X 95 sq. mm (45mm)

2

-

-

... More
3½ X 120 sq. mm (45mm)

4

-

-

... More
3½ X 150 sq. mm (50mm)

2

-

-

... More
3½ X 185 sq. mm (57mm)

4

-

-

... More
3½ X 240 sq. mm (62mm)

5

-

-

... More
3½ X 300 sq. mm (70mm)

5

-

-

... More
3½ X 400 sq. mm (82mm)

2

-

-

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other joining materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 16 sq. mm

2

-

-

... More
4 X 25 sq. mm

2

-

-

... More
3½ X 35 sq. mm

1

-

-

... More
3½ X50 sq. mm

1

-

-

... More
3½ X 70 sq. mm

1

-

-

... More
3½ X 95 sq. mm

1

-

-

... More
3½ X 120 sq. mm

1

-

-

... More
3½ X 150 sq. mm

1

-

-

... More
3½ X 185 sq. mm

5

-

-

... More
3½ X 240 sq. mm

10

-

-

... More
3½ X 300 sq. mm

5

-

-

... More
3½ X 400 sq. mm

2

-

-

... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 11 KV grade as required

-

-

-

... More
150 Sq. mm

1

-

-

... More
185 Sq.mm

1

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 11 KV grade as required

-

-

-

... More
150 Sq. mm

1

-

-

... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 Core, XLPE Aluminium Conductor cable of 11 KV grade as required

-

-

-

... More
150 Sq. mm

10

-

-

... More
185 Sq.mm

1

-

-

... More
Identification and locating the Cable fault on LT/HT feeder cables laid in ground/ duct/ pipe including providing Cable Fault Tracer (Rental), hiring of JCB and additional manpower required etc., as required. [AS AND WHEN REQUIRED BASIS ONLY] Note: One job means identification and locating any number of faults on the same cable.

-

-

-

... More
LT CABLES

4

-

-

... More
HT CABLES

4

-

-

... More
SUPPLY & LAYING OF HDPE PIPES

-

-

-

... More
Supplying and laying of 75 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (75 cm below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.

100

-

-

... More
Supplying and laying of 125 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (75 cm below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as and when required.

250

-

-

... More
Supplying and laying of 125 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like socket, bend etc., confirming to IS 4984 complete with fitting and cutting, jointing etc., direct in ground (1.2 mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.

150

-

-

... More
SH-V-B : EARTHING

-

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required

4

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required

2

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of brass nut bolt & spring washer spaced at 50mm)

25

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of G.I. nut bolt & spring washer spaced at 50mm)

25

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required

25

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required

50

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required

25

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required

100

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

2

-

-

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required

25

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required

100

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
Providing and fixing MV danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

25

-

-

... More
Supply of nominal 2.5 mm thick (Width 1 Mtr) PVC synthetic, electric insulated mats conforming to IS 15652-2006 having Dielectric strength of 45 KV, no adverse effect of mineral oil, high insulation resistance (Minimum 1,00,000 M Ω on wet condition with 5 KV meggar) etc., as required.

5

-

-

... More
Supply of nominal 2.0 mm thick (Width 1 Mtr) PVC synthetic, electric insulated mats conforming to IS 15652-2006 having Dielectric strength of 30 KV, no adverse effect of mineral oil, high insulation resistance (Minimum 1,00,000 M Ω on wet condition with 5 KV meggar) etc., as required.

5

-

-

... More
SH-V-C : SITC of Switch Gear Works

-

-

-

... More
Supply, Replacement, Testing and Commissioning of 400 A 4P, 50 KA, MCCB with thermal magnetic release, adjustable overload setting, in the existing Panel including providing Handle, with all accessories, with all accessories, interconnection, connection, earthing, painting of door, etc. as required. Similar to L&T DU 400N

1

-

-

... More
Supply, Replacement, Testing and Commissioning of 250 A 4P, 36 KA, MCCB with thermal magnetic release, adjustable overload setting, in the existing Panel including providing Handle, with all accessories, with all accessories, interconnection, connection, earthing, painting of door, etc. as required. Similar to L&T DU250

2

-

-

... More
Supply, Replacement, Testing and Commissioning of 125 A 4P 18 KA MCCB with thermal magnetic release, adjustable overload setting, in the existing Panel including providing Handle, with all accessories, with all accessories, interconnection, connection, earthing, painting of door, etc. as required. Similar to L&T DU 125D

2

-

-

... More
Supply, Replacement, Testing and Commissioning of 63 A 4P 18 KA MCCB with thermal magnetic release, adjustable overload setting, in the existing Panel including providing Handle, with all accessories, with all accessories, interconnection, connection, earthing, painting of door, etc. as required. Similar to L&T DU 100D

5

-

-

... More
Supply, Replacement, Testing and Commissioning of digital multifunction meter having metering class 1.0 with RS485 (having measuring parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, THD) in the existing Panel including with all acessories, interconnection, connection, etc. as required. Similar to L&T MFM4410

5

-

-

... More
Supply, Replacement, Testing and Commissioning of LED indication lamps (Colors : R/Y/G/A) having 22.5 mm dia with suitable voltage as per the site requirement in the existing Panel including with all acessories, interconnection, connection, etc. as required.

100

-

-

... More
Supply, Replacement, Testing and Commissioning of Blue Color LED indication lamp having 22.5 mm dia with suitable voltage as per the site requirement in the existing Panel including with all acessories, interconnection, connection, etc. as required.

50

-

-

... More
Supply, Replacement, Testing and Commissioning of Panel Lock with key having size of 22.5 mm dia in the existing Panel as required.

10

-

-

... More
SH-V-D : Labour Works

-

-

-

... More
Providing One Unskilled Khalasi to assist any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency Work at Electrical Installations provided in Main Power House/ Substations with necessary T&P as and when required.

48

-

-

... More
Providing Labour and Hire Charges for deploying Excavater (JCB) i/c Operator for excavation and refilling of Cable trench after work etc., as required.

50

-

-

... More
Providing one FITTER and ONE Unskilled Khalasi to attend any urgent Preventive Maintenance/ Breakdown Maintenance/ Emergency Work at Electrical Installations provided in Main Power House/Substations with necessary T&P as and when required.

24

-

-

... More
Providing unskilled labour (one person) and Hire Charges for deploying WELDING MACHINE i/c WELDER, Welding Rods etc., for WELDING WORKS as required.

24

-

-

... More
Providing unskilled labour (one person) and hire charges for deploying Crane (upto 10 Ton) i/c operator for lifting/ Shifting of Equipments/ Cable Drums, etc., as required.

24

-

-

... More
SH-V-E : Civil Works

-

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required

-

-

-

... More
100 mm dia

18

-

-

... More
150 mm dia

12

-

-

... More
Supplying and laying of "B" Class G.I pipe of following dia, i/c excavation of bituminous/ concrete road/ pavement, excavation of Soil to maximum depth of 1.2 Mtrs from ground refilling the Soil and with CC of ratio 1:3:6 on top for 0.15 Mtrs after laying Pipe and plastering, making good the same etc., as required.

-

-

-

... More
100 mm Dia

30

-

-

... More
150 mm Dia

36

-

-

... More
Fabrication, Supply and Fixing of 6mm thick chequered plates including providing and fixing 40mmx40mmx6mm angle iron supports on cable trenches, 25mmx6mm MS flat around the chequered plate by welding, providing lifting hook etc., as required.

20

-

-

... More
Supply, fabrication and installation of the MS channel/ angle/ flat for cable tray/ support including cutting, welding, drilling, fixing, grinding, painting etc., as required for composite M.S. works as & when required basis.

10

-

-

... More
Painting of Power Supply / fire fighting installations with two coats of synthetic enamel paint of approved shade quality and brand after applying one coat of redoxide i/c scrapping and cleaning, providing putty wherever required and inscription etc., as required.

-

-

-

... More
Spraying

500

-

-

... More
Brushing

100

-

-

... More
SH-V-F : Supply of Cables and batteries

-

-

-

... More
Supply of Aluminium Conductor, XLPE insulated, PVC sheathed, armoured power cable of 1.1 KV grade of following Sizes conforming to IS 7098 (Part-1) as amended upto date as required. [AS AND WHEN REQUIRED BASIS ONLY]

-

-

-

... More
4 X 16 sq. mm

100

-

-

... More
4 X 25 sq. mm

150

-

-

... More
3½ X 35 sq. mm

100

-

-

... More
3½ X50 sq. mm

50

-

-

... More
3½ X 70 sq. mm

50

-

-

... More
3½ X 95 sq. mm

100

-

-

... More
3½ X 120 sq. mm

100

-

-

... More
3½ X 150 sq. mm

100

-

-

... More
3½ X 185 sq. mm

100

-

-

... More
3½ X 240 sq. mm

200

-

-

... More
3½ X 300 sq. mm

200

-

-

... More
3½ X 400 sq. mm

25

-

-

... More
Supply of compact circular stranded Al conductor provided with conductor screening of semi-conducting compound XLPE insulated provided with insulation screening over individual cores, consisting of extruded semi-conducting compound followed by lapped semi-conducting copper tapes, cores laid together with suitable filters, in the interscripes covered with inner sheath by extrusion, galvanized flat steel strip armoured and overall PVC sheathed cable, suitable for 11 KV (E) System conforming to IS 7098 (Part-II) 1985 as amended upto date and of following Size as required. [AS AND WHEN REQUIRED BASIS ONLY]

-

-

-

... More
3 X 150 Sq.mm

200

-

-

... More
3 X 185 Sq.mm

50

-

-

... More
Supply of following capacity sealed maintenance free batteries (minimum of 2 years warrenty ) with buy back of old batteries (as per list of approved makes).

-

-

-

... More
12V 7AH (for fire alarm panels and lift ARD)

30

-

-

... More
12V 18AH ( for Lift ARD)

15

-

-

... More
12V 100AH (for DG set)

4

-

-

... More
12V 180AH ( for DG set)

10

-

-

... More
SH-V-G : Fire Fighting Works

-

-

-

... More
Providing, laying, testing & commissioning of 150 mm dia 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.

80

-

-

... More
Providing, laying, testing & commissioning of 150mm dia 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground i/c welding, excavation and providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc., complete as required.

20

-

-

... More
Wrapping of existing Mild steel pipe with suitable 4mm thick insulation of tar felt sheet etc., complete as required as per the specifications.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.