Solar Power Plant Tenders

Solar Power Plant Tenders

Directorate Of Municipal Administration - DMA Tender

Works
Civil And Construction...+1Water Storage And Supply
Eprocure
Corrigendum : Corrigendum Added
Parbhani, Maharashtra
Details: Augmentation To Gangakhed Water Supply Scheme Under Maharastra Suvarn Jayanti Nagarotthan Maha Abhiyan, Tal.gangakhed, Dist.-parbhani. (masoli Source A) Approach Channel L-300 M , B) Repair Of Existing Jackwell Dia. 6.5 M @ Masoli Dam, C) Construction of Panel Room 8x6x5m , D)raw Water Pumping Machinery At Masoli Jackwell, (200 Hp V.t. Pumps, Discharging Cap. 419300 lph For Head 83 M - Total 3 Nos. 2+1 Nos With Automation Of Pumps ), E) Desilting Pump @ Masoli Jackweell F) Raw Water rising Main From Head Works To Bpt , (500 Mm Dia. D.i.k-9 Pipes- L =700 M) g)repairs To Existing Bpt (total Cap. 2,25,000 Ltr), H) Raw Water Gravity Main From Bpt To Wtp 350 Mm Dia. Di K7 Pipes ,l =1500 M , 400 Mm Dia. Di K-7 Pipe L = 6500m. Godavari Source I) Repair Of Intake Well @godavari - Dia 6 M & Depth 18 M, J) Repair Of Existing Jackwell Dia- 6 M Ht-8 M @godavari River, K) Raw Water Pumping Machinery At godawari Jackwell Q:- 34200 Lph Head H:-81m 20.0 Hp Submersible Monoblock Pump, L) Desilting Pump At Godavari River, m) Raw Warter Rising Main From Jackwell @ Godavari River To Wtp Di K-9 Dia- 200mm Length - 4500 M. Combine subworks N)proposed Conventional Water Treatment Plant Capacity- 19 Mld O) Recirculation Sump Cap- 3,57,000 Lit, p) Raw Water Pumping Machinery At Recirculation Sump Q:-66640 Lph Head H:-12 M 7.5 Hp Submersible Pump (2+1), Q) rising Main From Recirculation Sump To Wtp Di K-9, Dia-200 Mm Length -100m, R) Pure Water Pumping Machinery Q403400 Lph Head H:-33 M 90 Hp Vt Pump (2+1), S)pure Water Rising Main From Wtp To Mbr Di K-9, Dia-500 Mm Length - 1200 M, T) Mbr For Gangakhed (total Cap:- 15,34,000 Lit), U) Pure Water Gravity Main From Mbr To Various Esr's Dia200mm To 700mm Length-6467m, V) Provision For Repairs To Existing Rcc Elevated Storage Reservoir At Gangakhed (total Cap:- 13,00,000 Lit), W) Rcc Elevated Storage Reservoir At Gangakhed (total Cap:- 25,14,000 Lit), X) distribution System Hdpe Pe- 6kg/cm^2 Dia 110 Mm To 225 Mm & Di K-9 Dia 250 Mm To 500 Mm Total Length - 125.00 Km Y) Running The Scheme On Trial Basis, Miscellaneous Works, Solar Power Plant 510 Kwp, automation (scada ) Etc Complete.)
Closing Date5 Aug 2024
Tender Amount₹ 78.7 Cr 

Hindustan Petroleum Corporation Limited - HPCL Tender

Services
Energy, Oil and Gas...+4Solar Installation and Products, Consultancy Services, Electrical and Electronics, Civil And Architectural Services
Jaisalmer - Rajasthan, Barmer - Rajasthan
+1Visakhapatnam, Andhra Pradesh
Details: Pre-tender Meeting For Publishing Tender Towards Selection Of Epc Contractor For Design, Engineering, Procurement, Construction, Testing, Commissioning, And Operation & Maintenance Of A Floating Solar Photovoltaic (fspv) Power Plants. All The Prospective Interested Bidders May Participate In The Pre - Tender Meeting Through Video Conference At 12:00 Pm 26.08.2024 With Following Link. Https://hpcl-in.zoom.us/j/99471002345?pwd=bybsc9loxtazytzlgwbn50pm5zvhvc.1 Meeting Id: 994 7100 2345 Passcode: 846846
Closing Date26 Aug 2024
Tender AmountRefer Documents 

Directorate General Of Employment And Training - DGET Tender

Goods
Solar Installation and Products...+1Electrical and Electronics
GEM
Corrigendum : Corrigendum Added
South Andaman, Andaman & Nicobar Islands
Description: CATEGORY: Measuring Steel Tape , Combination Plier Insulated , Screw Driver Insulated , Electrician screw driver thin stem insulated handle , Heavy Duty Screw Driver insulated , Electrician Screw Driver thin stem insulated handle , Punch Centre , Knife Double Bladed Electrician , Neon Tester , Steel Rule , Hammer Cross pein , Electrical Symbol and Accessories Charts , Pipe vice , Hand Vice , Table Vice , Hacksaw frame with blade , File flat , File half round , File round , Pliers ,long nose , Pliers flat nose insulated , Pliers, round nose insulated , D.E. metric Spanner Double Ended , Wire Gauge imperial stainlees , Portable Electric Drill Machine , Crimping Tool , Pliers Side Cutting , Wire stripper adjustable length , Hammer ball peen With wooden handle , Scriber , Tool kit Box or bag portable , Allen Key , Scissors blade , Electrical load board , Torque wrench , Pipe Cutter to cut pipes , Try Square , Multi Meter analog , Load Bank variable , Wire Cutter and Stripper , Earth Plate , Earth Electrode , Out Side Micrometer , Tap and Die set , Trolley for Transportation of Batteries , Rooftop Mounting Structure , Electrical wiring and switch gear rack , Protective relays and contactors rack , MCCB , ELCB and RCCB , Fuses , Digital Multimeter , Megger , Hydrometer , Solar Insulation meter , Pyranometer , Pyrheliometer , Lux meter , Magnetic Flux Meter , Tong Tester or Clamp Meter , Soldering Iron , Temperature controlled Soldering Iron , Thermometer Digital , Sun Shine recorder , Weather monitoring station , Solar cell based sunlight radiation meter , Magnetic compass , Cut models of photo voltaic cell assembly , Cut model of Lead acid battery , Lead Acid battery , Solar simulator for solar cell characteristic study , I V Curve tester , Sun path finder , Solar energy trainer with grouping of solar cells , Solar tracker demonstrator kit , Solar PV e- learning software using animations for training , Halogen lamp with stand for illumination of solar panels in lab , Motorized Bench Grinder , Battery Charger , Solar photovoltaic module , Solar panels , Solar Charge controller with Dusk to Dawn automatic switching , Solar charge controller with manual switch Day lighting , Array junction box , Solar lantern , Solar lantern assembly sets , Home light system , Solar cell kit , Clinometer , Spirit level , Anemometer , DC table fan , AC Voltmeter Moving Iron , Volt meter , Ammeter MC , Ammeter MC centre zero , Power Factor Meter , Rheostat , AC Energy Meter , Kilo Wattmeter Analog , Digital Wattmeter , Phase Sequence Indicator , Frequency Meter , DC LED Lamp , DC Pump , PWM Controller , MPPT Charge Controller , Inverter with Battery , Solar PCU , Solar Grid tied inverter Demonstrator kit , Solar Street Light , Solar wind hybrid power plant , Solar Traffic Light , Water treatment solar plant demonstrator kit , Solar DC pump , Demonstration kit for wind generation Wind turbine with blower , Working Bench , Wiring Board
Closing Date18 May 2024
Tender Amount₹ 19.9 Lac 

Western Railway - WR Tender

Goods
Energy, Oil and Gas...+2Solar Installation and Products, Electrical and Electronics
Ireps
Vadodara, Gujarat
Details: Description:- Design, Supply, Installation, Testing And Commissioning Of "on Grid" Solar Photovoltaic Power plant With Required Solar Mono Crystalline Pv Modules, Ms Hot Dipped Galvanized Structure For Mounting Of panels, Suitable Power Conditioning Units Able To Adjust Voltage And Frequency Level To Suit The Grid Voltage frequency, Array And Main Junction Boxes With Ip 65 Protection, Required Ac And Dc Distribution Boards With switchgear, Armoured Power And Control Cables, Remote Data Monitoring System, Concerned State Electricity Board approved Bidirectional Energy Metering System (net Metering Applicable As Per Availability Of Power Supply Lt Or ht);htmeteringcubicleenclosurewithbusbar,changeoverarrangement,currenttransformers,solar generation Meter Box As Required, Earthing Arrangements, Suitable Lightening And Surge Protection As Per Detailed specifications Including All Necessary Allied Works/accessories As Per Site Condition, Liaison, Registration, Inspection and Any Other Charges Of Discoms Shall Be Borne By Contractor. The Successful Contractor Shall Survey The proposed Sites And Submit The Gad For Approval To Sr. Divisional Electrical Engineer (power) Vadodara Before commencing The Work. The Work Shall Be Warranted For A Period Of Five Years From The Date Of Completion. detailed Technical Specifications Are Given In Annexure-xx Of Tender Document.
Closing Date17 Jun 2024
Tender Amount₹ 4.4 Cr 

Western Railway - WR Tender

Goods
Energy, Oil and Gas
Ireps
Vadodara, Gujarat
Details: Description:- Design, Supply, Erection, Testing And Commissioning Of Grid Connected Rooftop Solar Pv System With mono Crystalline Panel Complete With All Accessories, Monitoring System, Inverter, Structure, Cables, Net Metering etc Complete With Five Years' Warrantee - Design, Supply, Installation, Testing And Commissioning Of "on Grid" solar Photovoltaic Power Plant With Required Solar Mono Crystalline Pv Modules, Ms Hot Dipped Galvanized structure For Mounting Of Panels, Suitable Power Conditioning Units Able To Adjust Voltage And Frequency Level To suit The Grid Voltage Frequency, Array And Main Junction Boxes With Ip 65 Protection, Required Ac And Dc distributionboardswithswitchgear,armouredpowerandcontrolcables,remotedatamonitoringsystem, concerned State Electricity Board Approved Bidirectional Energy Metering System (net Metering Applicable As Per availability Of Power Supply Lt Or Ht); Ht Metering Cubicle Enclosure With Bus Bar, Changeover Arrangement, current Transformers, Solar Generation Meter Box As Required, Earthing Arrangements, Suitable Lightening And surgeprotectionasperdetailedspecificationsincludingallnecessaryalliedworks/accessoriesaspersite condition, Liaison, Registration, Inspection And Any Other Charges Of Discoms Shall Be Borne By Contractor. The successful Contractor Shall Survey The Proposed Sites And Submit The Gad For Approval To Sr. Divisional Electrical engineer (power) Vadodara Before Commencing The Work. The Work Shall Be Warranted For A Period Of Five Years from The Date Of Completion. Detailed Technical Specifications Are Given In Annexure-xx Of Tender Document.
Closing Date12 Feb 2024
Tender Amount₹ 5.7 Cr 

Western Railway - WR Tender

Works
Civil And Construction...+5Energy, Oil and Gas, Solar Installation and Products, Consultancy Services, Electrical and Electronics, Civil And Architectural Services
Ireps
Vadodara, Gujarat
Details: Description:- Design, Supply, Installation, Testing And Commissioning Of "on Grid" Solar Photovoltaic Power Plant With Required Solar Mono crystalline Pv Modules, Ms Hot Dipped Galvanized Structure For Mounting Of Panels, Suitable Power Conditioning Units Able To Adjust Voltage And frequency Level To Suit The Grid Voltage Frequency, Array And Main Junction Boxes With Ip 65 Protection, Required Ac And Dc Distribution Boards With switchgear, Armoured Power And Control Cables, Remote Data Monitoring System, Concerned State Electricity Board Approved Bidirectional Energy metering System (net Metering Applicable As Per Availability Of Power Supply Lt Or Ht); Ht Metering Cubicle Enclosure With Bus Bar, Changeover arrangement, Current Transformers, Solar Generation Meter Box As Required, Earthing Arrangements, Suitable Lightening And Surge Protection As Per detailed Specifications Including All Necessary Allied Works/accessories As Per Site Condition, Liaison, Registration, Inspection And Any Other Charges Of discoms Shall Be Borne By Contractor. The Successful Contractor Shall Survey The Proposed Sites And Submit The Gad For Approval To Sr. Divisional electrical Engineer (power) Vadodara Before Commencing The Work. The Work Shall Be Warranted For A Period Of Five Years From The Date Of completion. Detailed Technical Specifications Are Given In Annexure-xx Of Tender Document. The Tentative Sites Of Work Are Given In Annexure-xxi Of tender Document.
Closing Date17 Oct 2024
Tender Amount₹ 5.1 Cr 

Integral Coach Factory Tender

Works
Solar Installation and Products
Ireps
Corrigendum : Tender Amount Updated
Chennai, Tamil Nadu
Details: Description:- Design, Supply, Erection, Testing & Commissioning Of "on Grid Solar Roof Top Photovoltaic Power plant Of Capacity 145kwp" In The Following Locations Of Icf Comprising Of Spv Modules, Mounting Structures, power Conditioning Units, Junction Boxes, Distribution Boxes Cables & Wires, Lightning Arrestor, Earthing Kits, Pvc pipes& Accessories And Monitoring System As Per Icf Specification. Location 1 - Arun Stadium - 25 Kwp, location 2 - Shell Factory Canteen - 30 Kwp, Location 3 - Furnishing Canteen - 40 Kwp, Location 4 - Officer's rest House/perambur - 40 Kwp, Location 5 - Rpf Hostel - 10 Kwp".
Closing Date9 Oct 2024
Tender Amount₹ 86.6 Lac 

Skill Development And Technical Education Department Tender

Goods
Electronics Equipment...+2Solar Installation and Products, Electrical and Electronics
GEM
Corrigendum : Corrigendum Added
Baleshwar, Odisha
Description: CATEGORY: Temperature controlled Soldering Iron , Solar Insulation m Weather monitoring station , Solar cell based sunlight radi meter , Solar simulator for solar cell characteristic study , I tester , Sun path finder , Solar energy trainer with groupin solar cells , Solar tracker demonstrator kit , Motorized Ben Grinder , Array junction box , Solar lantern assembly sets , light system , Solar cell kit , Clinometer , DC table fan , A.C Energy Meter , Kilo Wattmeter Analog , Digital Wattmeter , Sequence Indicator , DC LED Lamp , DC Pump , PWM Contr MPPT Charge Controller , Solar PCU , Solar Grid tied invert Demonstrator kit , Solar, wind and hybrid power plant , Sol Traffic Light , Used water treatment solar plant demonstrat solar DC pump , Demonstration kit for wind generation Wi turbine with blower , Rechargeable battery , Halogen lamp stand for illumination of solar panels in lab , Solar Charge controller with Dusk to Dawn automatic switching , Solar c controller with manual switch Day lighting , Combination Pl Insulated , Electrician screw driver thin stem insulated han Heavy Duty Screw Driver insulated , Electrician Screw Driv stem insulated handle , Punch Centre , Knife Double Blade Electrician , Neon Tester , Steel Rule Graduated both in Me English Unit , Hand Vice , Table Vice , Hacksaw frame with File flat , File half round , File round , Pliers long nose insul Pliers flat nose insulated , D.E. metric Spanner Double End Portable Electric Drill Machine , Pliers Side Cutting , Wire st adjustable length , Hammer ball peen With handle , Scribe Knurled centre position , Tool kit Box bag portable , Scisso , Load Bank variable type , Wire Cutter and Stripper , Earth Earth Electrode , Out Side Micrometer , Tap set , Die for Th , Thermometer Digital
Closing Date27 Feb 2024
Tender AmountRefer Documents 

Hindustan Petroleum Corporation Limited - HPCL Tender

Goods
Civil And Construction...+3Real Estate Service, Consultancy Services, Civil And Architectural Services
GEM
Corrigendum : Closing Date Modified
Mumbai, Maharashtra
Description: CATEGORY: EPC 14MWp Solar Plant BSES Rajdhani DISCOM , Land Lease Agreement value 1st YEAR , Land Lease Agreement value 2nd YEAR , Land Lease Agreement value 3rd YEAR , Land Lease Agreement value 4th YEAR , Land Lease Agreement value 5th YEAR , Land Lease Agreement value 6th YEAR , Land Lease Agreement value 7th YEAR , Land Lease Agreement value 8th YEAR , Land Lease Agreement value 9th YEAR , Land Lease Agreement value 10th YEAR , Land Lease Agreement value 11th YEAR , Land Lease Agreement value 12th YEAR , Land Lease Agreement value 13th YEAR , Land Lease Agreement value 14th YEAR , Land Lease Agreement value 15th YEAR , Land Lease Agreement value 16th YEAR , Land Lease Agreement value 17th YEAR , Land Lease Agreement value 18th YEAR , Land Lease Agreement value 19th YEAR , Land Lease Agreement value 20th YEAR , Land Lease Agreement value 21st YEAR , Land Lease Agreement value 22nd YEAR , Land Lease Agreement value 23rd YEAR , Land Lease Agreement value 24th YEAR , Land Lease Agreement value 25th YEAR , Land Lease Agreement value 26th YEAR , Land Lease Agreement value 27th YEAR , Power evacuation set up for 1MW , Power evacuation set up for 1.5 MW , Power evacuation set up for 2 MW , Power evacuation set up for 2.5 MW , Power evacuation set up for 3 MW , Power evacuation set up for 3.5 MW , Power evacuation set up for 4 MW , COMC Post Defect Liability Period for 1st Year , COMC Post Defect Liability Period for 2nd Year , COMC Post Defect Liability Period for 3rd Year , COMC Post Defect Liability Period for 4th Year , COMC Post Defect Liability Period for 5th Year , COMC Post Defect Liability Period for 6th Year , COMC Post Defect Liability Period for 7th Year , COMC Post Defect Liability Period for 8th Year , COMC Post Defect Liability Period for 9th Year , COMC Post Defect Liability Period for 10th Year , EPC 14MWp Solar Plant Tata Power DISCOM
Closing Date31 Oct 2024
Tender Amount₹ 203.1 Cr 
This is an estimated amount, exact amount may vary.

South Western Railway - SWR Tender

Works
Solar Installation and Products...+1Electrical and Electronics
Ireps
Corrigendum : Tender Amount Updated
NA
Details: Description:- Supply, Installation, Testing And Commissioning Of On-grid, Rooftop Mounted Solar Photovoltaic power Plants Of 05 To 50 Kwp Capacity, Net Metering Type, To Be Installed At Various Buildings / Covered Platforms at Different Railway Stations (56 Nos) Under Hubballi Division. Conforming To Mnre Specifications As Amended and As Per Tender Conditions. The Plant Consisting Of Mono Crystalline Silicon Solar Cells, Net Metering Facility, necessary Protections, Earthing, Mounted On Gi Structure Suitable As Per Site Requirements And Withstand A Wind velocity Of 150 Kms Per Hour. Carrying Out Maintenance For A Period Of 36 Months After Completion Of The Work including Following Components Complete As Required:- A) Solar Photovoltaic Module Of Capacity 330 Wp Or Above, manufacturedinindia,conformingtois14286/iec61215,is/iec61730-part1,is/iec61730-part-2.solar photovoltaicmoduleconversionefficiencyshallnotbelessthan16.5%.pvmodulesusedinsolarpower plants/systems Must Be Warrantied For Their Output Peak Watt Capacity, Which Should Not Be Less Than 90% At The end Of 10 Years And 80% At The End Of 25 Years. B) Power Conditioning Unit (pcu) Of 250-800 V Dc Input Voltage range And 400 V Ac, Three Phase, 50hz+/-2.5hz,, 50hz+/-2.5hz, Output Voltage Suitable To Generate Ac Power with Efficiency Not Less Than 97%, Total Harmonic Distortion Less Than 3% And Suitable For Ambient Temperature from 0 To 50 Degree C. The Pcu Shall Adjust The Voltage And Frequency Level To Suit The Grid Voltage Frequency. all Outdoor Panels Must Be Protected With Ip-65 Ratings Or Above. C) Online Data Monitoring System Complete With accessories. D)fixingofarrayjunctionbox&mainjunctionboxwithip65 Protection Andtermination arrangement For Incoming And Outgoing Cable Along With Glands, Lugs And Other Accessories Etc. As Required. E) lightning And Surge Voltage Protection. F) Connections & Interconnections By Supplying & Fixing Required Size, single Core Xlpe Insulated Copper Conductor 1.1 Kv Grade Armored Power And Control Cables For Dc System And xlpe Insulated Armoured, 4 Core Aluminium Conductor Cables Of Suitable Size Between Ac Panel To Domestic Lt panel. Pcu Unit Along With Supplying & Fixing Of Necessary Channel/ Conduit Lugs And Other Accessories Etc. suitable Skid Free Walkway Provision On Sloppy Roof For Cleaning Purpose Wherever Required For Plants More Than 10 Kwp Capacity Complete All As Specified In The Tender Documents And As Directed At Site. Note: Lt Xlpe Ug cable From The Domestic Lt Panel To Grid Supply Connections / Up To Termination Point Will Be Supplied By Railways.
Closing Date3 Oct 2024
Tender Amount₹ 15.8 Cr 
2441-2450 of 2450 archived Tenders