Solar Power Plant Tenders

Solar Power Plant Tenders

Hindustan Petroleum Corporation Limited - HPCL Tender

Goods
Civil And Construction...+3Real Estate Service, Consultancy Services, Civil And Architectural Services
GEM
Corrigendum : Closing Date Modified
Mumbai, Maharashtra
Description: CATEGORY: EPC 14MWp Solar Plant BSES Rajdhani DISCOM , Land Lease Agreement value 1st YEAR , Land Lease Agreement value 2nd YEAR , Land Lease Agreement value 3rd YEAR , Land Lease Agreement value 4th YEAR , Land Lease Agreement value 5th YEAR , Land Lease Agreement value 6th YEAR , Land Lease Agreement value 7th YEAR , Land Lease Agreement value 8th YEAR , Land Lease Agreement value 9th YEAR , Land Lease Agreement value 10th YEAR , Land Lease Agreement value 11th YEAR , Land Lease Agreement value 12th YEAR , Land Lease Agreement value 13th YEAR , Land Lease Agreement value 14th YEAR , Land Lease Agreement value 15th YEAR , Land Lease Agreement value 16th YEAR , Land Lease Agreement value 17th YEAR , Land Lease Agreement value 18th YEAR , Land Lease Agreement value 19th YEAR , Land Lease Agreement value 20th YEAR , Land Lease Agreement value 21st YEAR , Land Lease Agreement value 22nd YEAR , Land Lease Agreement value 23rd YEAR , Land Lease Agreement value 24th YEAR , Land Lease Agreement value 25th YEAR , Land Lease Agreement value 26th YEAR , Land Lease Agreement value 27th YEAR , Power evacuation set up for 1MW , Power evacuation set up for 1.5 MW , Power evacuation set up for 2 MW , Power evacuation set up for 2.5 MW , Power evacuation set up for 3 MW , Power evacuation set up for 3.5 MW , Power evacuation set up for 4 MW , COMC Post Defect Liability Period for 1st Year , COMC Post Defect Liability Period for 2nd Year , COMC Post Defect Liability Period for 3rd Year , COMC Post Defect Liability Period for 4th Year , COMC Post Defect Liability Period for 5th Year , COMC Post Defect Liability Period for 6th Year , COMC Post Defect Liability Period for 7th Year , COMC Post Defect Liability Period for 8th Year , COMC Post Defect Liability Period for 9th Year , COMC Post Defect Liability Period for 10th Year , EPC 14MWp Solar Plant Tata Power DISCOM
Closing Date31 Oct 2024
Tender Amount₹ 203.1 Cr 
This is an estimated amount, exact amount may vary.

South Western Railway - SWR Tender

Works
Solar Installation and Products...+1Electrical and Electronics
Ireps
Corrigendum : Tender Amount Updated
NA
Details: Description:- Supply, Installation, Testing And Commissioning Of On-grid, Rooftop Mounted Solar Photovoltaic power Plants Of 05 To 50 Kwp Capacity, Net Metering Type, To Be Installed At Various Buildings / Covered Platforms at Different Railway Stations (56 Nos) Under Hubballi Division. Conforming To Mnre Specifications As Amended and As Per Tender Conditions. The Plant Consisting Of Mono Crystalline Silicon Solar Cells, Net Metering Facility, necessary Protections, Earthing, Mounted On Gi Structure Suitable As Per Site Requirements And Withstand A Wind velocity Of 150 Kms Per Hour. Carrying Out Maintenance For A Period Of 36 Months After Completion Of The Work including Following Components Complete As Required:- A) Solar Photovoltaic Module Of Capacity 330 Wp Or Above, manufacturedinindia,conformingtois14286/iec61215,is/iec61730-part1,is/iec61730-part-2.solar photovoltaicmoduleconversionefficiencyshallnotbelessthan16.5%.pvmodulesusedinsolarpower plants/systems Must Be Warrantied For Their Output Peak Watt Capacity, Which Should Not Be Less Than 90% At The end Of 10 Years And 80% At The End Of 25 Years. B) Power Conditioning Unit (pcu) Of 250-800 V Dc Input Voltage range And 400 V Ac, Three Phase, 50hz+/-2.5hz,, 50hz+/-2.5hz, Output Voltage Suitable To Generate Ac Power with Efficiency Not Less Than 97%, Total Harmonic Distortion Less Than 3% And Suitable For Ambient Temperature from 0 To 50 Degree C. The Pcu Shall Adjust The Voltage And Frequency Level To Suit The Grid Voltage Frequency. all Outdoor Panels Must Be Protected With Ip-65 Ratings Or Above. C) Online Data Monitoring System Complete With accessories. D)fixingofarrayjunctionbox&mainjunctionboxwithip65 Protection Andtermination arrangement For Incoming And Outgoing Cable Along With Glands, Lugs And Other Accessories Etc. As Required. E) lightning And Surge Voltage Protection. F) Connections & Interconnections By Supplying & Fixing Required Size, single Core Xlpe Insulated Copper Conductor 1.1 Kv Grade Armored Power And Control Cables For Dc System And xlpe Insulated Armoured, 4 Core Aluminium Conductor Cables Of Suitable Size Between Ac Panel To Domestic Lt panel. Pcu Unit Along With Supplying & Fixing Of Necessary Channel/ Conduit Lugs And Other Accessories Etc. suitable Skid Free Walkway Provision On Sloppy Roof For Cleaning Purpose Wherever Required For Plants More Than 10 Kwp Capacity Complete All As Specified In The Tender Documents And As Directed At Site. Note: Lt Xlpe Ug cable From The Domestic Lt Panel To Grid Supply Connections / Up To Termination Point Will Be Supplied By Railways.
Closing Date3 Oct 2024
Tender Amount₹ 15.8 Cr 
2431-2440 of 2432 archived Tenders