Power Department Tender

View complete overview of Sikkim Power Department Tender

Power Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Aug 2023
Closing Date19 Sep 2023
Tender Amount₹ 40,00,00,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b) Bus Coupler Panels (01 No per Switching Station)

2

-

-

... More
c) Outgoing Feeder Panel (04 Nos per Switching Station)

8

-

-

... More
Outdoor Type Distribution Transformer (Station Service) :200 KVA, 11/0.433 KV , 3-phase, copper winding. (hermatically sealed, outdoor type) with off load tapping + 2.5 %, + 5%

2

-

-

... More
H.G. Fuse with mountring structure / channels for Station Service Transformer

2

-

-

... More
1.1 kV Grade XLPE/Cu 4 x 120 sqmm Armoured Cable for LVDB connection

60

-

-

... More
L.T. distribution Switch Board, outdoor kiosk type, 400 Amp, electrolytic annealed copper bus bar 50x12 mm for phase & 50x6 mm for neutral circuits mounted on glazed porcelain or bakelite base complete with voltmeter, ammeter, selector switches for ammeter & voltmeter, digital KWH meter, indicating lamps, cabin light with enclosure fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of shade 631 as per IS:5, front & back opening doors with Gasket and locking arrangement, complete with the following : Incomer Fdr Breaker : 1 No. 400A, 415 V, Four Pole MCCB, 50 KA with built in Thermo Magnetic Release. Outgoing Fdr Breakers : 1 X 200A + 3 x 100A + 1 63A TP MCCBs, 35 KA with built in Thermo Magnetic Release

2

-

-

... More
POWER CABLES AND ACCESSORIES

-

-

-

... More
11 KV (E) Stranded compact circular aluminium conductor screened with extruded semiconductering compound, TR-XLPE insulsted, Insulation screened with extruded semiconductering compound in combination with copper tape, cores laid up, PVC sheathed (ST-2 pvc), galvanised steel strip armoured, and overall PVC sheathed (ST-2 PVC) BLACK CABLE conferming to IS:7098 latest amendments;

-

-

-

... More
3 X 95 sq mm

700

-

-

... More
Heat shrinkable Indoor type end termination kit for 11 KV (E) 3 Core XLPE Cable including screen and armour earth kits, lugs and all accessories for cable;

-

-

-

... More
3 X 95 sq mm

8

-

-

... More
Heat shrinkable Outdoor type End termination kit for 6.6KV (UE) / 11 KV (E) 3 Core XLPE cable including screen and armour earth kits, lugs and all accessories for cable;

-

-

-

... More
3 X 95 sq mm (For OG feeders and Station Service Tr)

12

-

-

... More
D.C. EQUIPMENT

-

-

-

... More
Dry type maint free battery packs of capacity 200 AH 55 nos x 2 volt with terminal voltage of 110 volt complete with all accessories as required.

2

-

-

... More
Battery charging sets , one for trickle charging and other for boost charging suitable for operateion as detailed in the specification . Each charging set shall be complete with necessary transformers proective control gear, indicating instrument such as ammeters, voltmeters and indicating lamps and other accessories all suitably mounted for its satisfactory operation.

2

-

-

... More
110V DCDB totally enclosed metal clad type complete with copper bus bar, cable socket, 200A MCCB for incoming and required MCB of 32A DP, 64A FP for outgoing DC supply feeders .

2

-

-

... More
CONTROL CABLES

-

-

-

... More
1.1 KV heavy duty PVC insulated PVC sheathed copper conductor control cable armoured of following sizes.

-

-

-

... More
10 C x2.5 sq.mm

120

-

-

... More
4 C x 2.5 sq.mm

90

-

-

... More
Items for Cable Terminations at Terminal Structures

-

-

-

... More
110 mm dia HDPE pipe, PE-100 material grade, PN 10, SDR 17, wall thickness 6.6 mm including coupling as required.

15

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing (suitable for CC), 9 kV , 10 KA, with earth lead disconnector and channel mounting brackets.

30

-

-

... More
G.I .channel 75X40X6mmX2.2 m long for DP for LA and HG Fuse

10

-

-

... More
Back clamps of 50x50x6 mm x 200 mm length G.I Angle for holding channel

10

-

-

... More
GI wire (8 SWG ) for earthing

24

-

-

... More
PORTABLE FIRE EXTINGUISHERS conforming to IS 2190: 1992

-

-

-

... More
4.5 Kg DCP Type

6

-

-

... More
4.5 Kg CO2 Type

6

-

-

... More
22.5 Kg CO2 type

6

-

-

... More
12 Fire buckets with stand

24

-

-

... More
Other Items

-

-

-

... More
Safety Insulation mat for indoor 11 kv Switchgear Panels 1m width

24

-

-

... More
Earthing

-

-

-

... More
All materials for Safe Earthing Model T-39 short time current 50 KA rms for 1 sec withstand , including 80 mm dia x 3 mtrs. G.I. electrode & two bags backfill chemical compound for auxilary transformer and control room

24

-

-

... More
G.I strips 35mmx6mm for looping earth in individual panels

140

-

-

... More
Mandatory Spare Parts and Tools

-

-

-

... More
Closing Coil 110V,48V,24V for 11 kV VCB

8

-

-

... More
Tripping coil 110 Volts ,48V,24V for 11 kV VCB

8

-

-

... More
Ammeter / Voltmeter selector switch

8

-

-

... More
Spring Charging Motor for 11 kV VCB

4

-

-

... More
Schedule B : New 11 kV Single Circuit Overhead Line, ACSR DOG Conductor, on 11 m lattice Structure supports

-

-

-

... More
11 m Long Steel Lattice Structure fabricated with 65 x 65 x 6 mm M.S. angles and 12 mm dia MS rods including bolts, nuts and washers as per specifications and drawing complete.

544

-

-

... More
11 kV Composite Polymer Tension Insulator 70 KN, B&S / T&C Type

2112

-

-

... More
11 kV Composite Insulator Tension Hardware Fittings suitable for DOG conductor

2112

-

-

... More
11 KV Pin Insulator (Polymer) with G.I Pin & fittings as required

288

-

-

... More
ACSR DOG Conductor 100 sqm, 6/4.72+7/1.57

97

-

-

... More
G.I. Wire 4 mm (8-SWG) for Continuous Earth

3520

-

-

... More
PG Clamp for ACSR Dog Conductor

1056

-

-

... More
Compression Joint for ACSR Dog conductor

96

-

-

... More
G.I .channel 75X40X6mmX2.2 m long for Double Poles Structures

96

-

-

... More
Back clamps of 65x65x6 mm x 300 mm length G.I Angle for holding channel

992

-

-

... More
G.I. nuts & bolts of 16mm dia.X 40mm length.

160

-

-

... More
G.I channel 75 X 40 X 6mm 1.8 m long for S.P.structure.

352

-

-

... More
G.I . Pole top channel 75 X 40 X 6mm X 0.3m long for S.P. structure.

96

-

-

... More
Structure Earthing Material : 25 x 3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination for soil treatement

256

-

-

... More
Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate

352

-

-

... More
Red oxide paint @ 2 ltr/ pole

1088

-

-

... More
Aluminium paint @ 1.5 ltr / pole

816

-

-

... More
G.I. Barbed Wire

1088

-

-

... More
Aliminium Biding Wire, 4 mm

32

-

-

... More
Continuous Earth Wire Clamp suitable for 8 SWG GI Wire

544

-

-

... More
11 kV Caution Board

448

-

-

... More
ADDITIONAL ITEMS FOR CRADLE GUARDING FOR LINE CROSSING (0.5X0.4 m GI wire mesh, One Guarding Span of 70 MTR PER 5 CKM of LINE)

-

-

-

... More
G.I. Guard Angles (65×65x6mm-2.2 m)

12

-

-

... More
G.I. Flat back clamp (50x6xmm - 2.2 m)

12

-

-

... More
G.I. Eye Bolt-16 mm

96

-

-

... More
G.I . Turn Buckle

48

-

-

... More
G.I. Wire 8 SWG (for guarding and grounding )

330

-

-

... More
G.I. wire 6 SWG (for guarding)

360

-

-

... More
Schedule C : New 11 kV Single Circuit Overhead Line, ACSR RABBIT Conductor, on 9 m lattice Structure supports

-

-

-

... More
9 m Long Steel Lattice Structure fabricated with 50 x 50 x 6 mm M.S. angles and 10 mm dia MS rods including bolts, nuts and washers as per specifications and drawing complete.

731

-

-

... More
11 kV Composite Polymer Tension Insulator 70 KN, B&S / T&C Type

2838

-

-

... More
11 kV Composite Insulator Tension Hardware Fittings suitable for DOG conductor

2838

-

-

... More
11 KV Pin Insulator (Polymer) with G.I Pin & fittings as required

387

-

-

... More
ACSR RABBIT Conductor 50 sqmm, 6/3.35+1/3.35

130

-

-

... More
G.I. Wire 4 mm (8-SWG) for Continuous Earth

4730

-

-

... More
PG Clamp for ACSR RABBIT Conductor

1419

-

-

... More
Compression Joint for ACSR RABBIT conductor

129

-

-

... More
G.I .channel 75X40X 4.8 mm X2.2 m long for Double Poles Structures

129

-

-

... More
Back clamps of 50x50x6 mm x 300 mm length G.I Angle for holding channel

1333

-

-

... More
G.I. nuts & bolts of 16mm dia.X 40mm length.

215

-

-

... More
G.I channel 75 X 40 X 4.8 mm 1.8 m long for S.P.structure.

473

-

-

... More
G.I . Pole top channel 75 X 40 X 4.8 mm X 0.3m long for S.P. structure.

129

-

-

... More
Structure Earthing Material : 25 x 3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination for soil treatement

344

-

-

... More
Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate

473

-

-

... More
Red oxide paint @ 1.5 ltr/ pole

1096.5

-

-

... More
Aluminium paint @ 1 ltr / pole

731

-

-

... More
G.I. Barbed Wire

1462

-

-

... More
Aliminium Biding Wire, 4 mm

43

-

-

... More
Continuous Earth Wire Clamp suitable for 8 SWG GI Wire

731

-

-

... More
11 kV Caution Board

602

-

-

... More
ADDITIONAL ITEMS FOR CRADLE GUARDING FOR LINE CROSSING (0.5X0.4 m GI wire mesh, One Guarding Span of 70 MTR PER 5 CKM of LINE)

-

-

-

... More
G.I. Guard Angles (65×65x6mm-2.2 m)

18

-

-

... More
G.I. Flat back clamp (50x6xmm - 2.2 m)

18

-

-

... More
G.I. Eye Bolt-16 mm

144

-

-

... More
G.I . Turn Buckle

72

-

-

... More
G.I. Wire 8 SWG (for guarding and grounding )

495

-

-

... More
G.I. wire 6 SWG (for guarding)

540

-

-

... More
Schedule D : New 11 kV Line Covered conductors on AAAC 100 sqmm on 11m and AAAC 70 sqmm on 9m lattice structure

-

-

-

... More
11 m Long Steel Lattice Structure fabricated with 65 x 65 x 6 mm M.S. angles and 12 mm dia MS rods including bolts, nuts and washers as per specifications and drawing complete.

680

-

-

... More
9 m Long Steel Lattice Structure fabricated with 50 x 50 x 6 mm M.S. angles and 10 mm dia MS rods including bolts, nuts and washers as per specifications and drawing complete.

970

-

-

... More
11 KV Polymeric Tension Insulator, 70 KN with Clamps, Nuts & Bolts

6435

-

-

... More
11 KV Class Polymeric Tension Hardware with Clamp suitable for covered conductor, Nuts & Bolts

6435

-

-

... More
11 KV Class Polymeric Pin Insulator for covered conductor with GI Pin, Nuts & Bolts

743

-

-

... More
Non-metallic helical top and side ties for covered conductor

743

-

-

... More
Insulating Piercing Connector for 11 kV CC to CC (XLPE/AAAC 50-150 sqmm) for jumpering

743

-

-

... More
Ead Cap (push-on type) for 11 kV covered conductor ( Size : 70 -100 sqmm) for jumper ends

1485

-

-

... More
Tension Jointing Kit for 11 KV Covered Conductor - 99 sqmm with insulation sleeves (compression or automatic type)

102

-

-

... More
Tension Jointing Kit for 11 KV Covered Conductor - 70 sqmm with insulation sleeves (compression or automatic type)

146

-

-

... More
Covered conductor, XLPE/AAAC 99 (or 100) Sq. mm.

103

-

-

... More
Covered conductor XLPE/AAAC 70 Sq. mm.

147

-

-

... More
G.I .channel 75X40X6mmX2.2 m long for Double Pole

330

-

-

... More
Back clamps of 65x65x6 mm x 300 mm length G.I Angle for holding channel

2888

-

-

... More
G.I. nuts & bolts of 16mm dia.X 40mm length.

413

-

-

... More
G.I. channel 75 X 40x4.8mm X 1.8 m long for S.P.structure.

990

-

-

... More
G.I. Pole top channel 75 X 40 X 6X 0.3 m long for S.P. structure.

102

-

-

... More
G.I. Pole top channel 75 X 40 X 4.8X 0.3 m long for S.P. structure.

146

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing , 9 kV , 10 KA, with earth lead disconnector, bird protection cap and mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer

990

-

-

... More
Insulating Piercing Connector for 11 kV CC (70-100 sqmm) to bare or insulated Al cable (16-50 sqmm) for LA

990

-

-

... More
1.1 kV , single core PVC/Al 25 sqmm cable for LA earthing including cable ties

5940

-

-

... More
LA Earthing : Safe earthing electrode Model T-19 withstanding short time current 20KA rms for 1 sec (MV) application:50 mm diameter x 2 mtrs. Electrode copper bonded & 1 bag backfill Chemical compound for soil treatement (to be installed 2 m away from structure earthing)

330

-

-

... More
Structure Earthing Material : 25 x 3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination for soil treatement

660

-

-

... More
Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate

990

-

-

... More
Red oxide paint @ 2 ltr/ pole

3300

-

-

... More
Aluminium paint @ 1.5 ltr / pole

2475

-

-

... More
G.I. Barbed Wire

3300

-

-

... More
11 kV Caution Board

1320

-

-

... More
G.I. Wire 4 mm (8-SWG) for Continuous Earth (& structure earthing)

9075

-

-

... More
Continuous Earth Wire Clamp suitable for 8 SWG GI Wire

1320

-

-

... More
Schedule E : New 11 kV Line on Underground cables

-

-

-

... More
3 x 240 sq.mm, 6.35 KV ( Uo) / 11 KV(U) TR-XLPE INSULATED, SCREENED, ARMOURED CABLE WITH ALUMINIUM CONDUCTOR CONFORMING TO IS:7098 PART-2.

5000

-

-

... More
3 x 185 sq.mm, 6.35 KV ( Uo) / 11 KV(U) TR-XLPE INSULATED,SCREENED, ARMOURED CABLE WITH ALUMINIUM CONDUCTOR CONFORMING TO IS:7098 PART-2.

5000

-

-

... More
3 x 120 sq.mm, 6.35 KV ( Uo) / 11 KV(U) TR-XLPE INSULATED, SCREENED, ARMOURED CABLE WITH ALUMINIUM CONDUCTOR CONFORMING TO IS:7098 PART-2.

8000

-

-

... More
3 x 95 sq.mm, 6.35 KV ( Uo) / 11 KV(U) TR-XLPE INSULATED, SCREENED, ARMOURED CABLE WITH ALUMINIUM CONDUCTOR CONFORMING TO IS:7098 PART-2.

8000

-

-

... More
160 mm. dia. (for 240/185/120 sq.mm cable) Rigid U PVC pipe as per IS 4985-2000 working pressure 6Kgf/cm2

18000

-

-

... More
110 mm. dia. (for 95/50 sq.mm cable) Rigid U PVC pipe as per IS 4985-2000 working pressure 6Kgf/cm2

8000

-

-

... More
Heat shrinkable straight through jointing kit suitable for 3 core 11 kV XLPE/ Al. screened, armoured cable of size 3 x 240 sq.mm

10

-

-

... More
Heat shrinkable straight through jointing kit suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x185 sq.mm

10

-

-

... More
Heat shrinkable straight through jointing kit suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x120 sq.mm

16

-

-

... More
Heat shrinkable straight through jointing kit suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x 95 sq.mm

16

-

-

... More
Heat shrinkable indoor / outdoor type end termination kit with including screen and armour earth kits, lugs and all accessories suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x 240 sq.mm (Provisional)

20

-

-

... More
Heat shrinkable indoor / outdoor type end termination kit with including screen and armour earth kits, lugs and all accessories suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x 185 sq.mm (Provisional)

20

-

-

... More
Heat shrinkable indoor / outdoor type end termination kit with including screen and armour earth kits, lugs and all accessories suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x 120 sq.mm (Provisional)

32

-

-

... More
Heat shrinkable indoor / outdoor type end termination kit with including screen and armour earth kits, lugs and all accessories suitable for 3 core 11 kV XLPE / Al. screened, armoured cable of size 3 x 95 sq.mm (Provisional)

32

-

-

... More
160 mm dia HDPE pipe, PE-100 material grade, PN 10, SDR 17, wall thickness 9.5 mm including coupling as required.

156

-

-

... More
U.G. Cable Joint Pit Cover with support mesh structure made of Galvanised M.S. Angle 65x65x8mm. and GI Checquered Plate 6mm thick with handle as per specifications and PWC requirements (Annexure-4)

52

-

-

... More
Duct sealing material / kit for duct dia 160 mm, sealing length upto 15 cm with expanding polyurethane filler or other sealant material suitable for U PVC/ HDPE sheathed cables .

104

-

-

... More
Cable route marker, plate type 100 mm dia with 60 cm shaft with helix, Marking " 11 kV Cable" and direction arrows.

130

-

-

... More
Schedule F :Conversion of exiting 11 kV ACSR Single Circuit Overhead Line to AAAC Covered Conductor, on 11 m lattice Structure supports

-

-

-

... More
11 m Long Steel Lattice Structure fabricated with 65 x 65 x 6 mm M.S. angles and 12 mm dia MS rods including bolts, nuts and washers as per specifications and drawing complete. (Provisional)

450

-

-

... More
11 KV Polymeric Tension Insulator, 70 KN with Clamps, Nuts & Bolts

3900

-

-

... More
11 KV Class Polymeric Tension Hardware with Clamp suitable for covered conductor, Nuts & Bolts

3900

-

-

... More
11 KV Class Polymeric Pin Insulator for covered conductor with GI Pin, Nuts & Bolts

450

-

-

... More
Non-metallic helical top and side ties for covered conductor

450

-

-

... More
Insulating Piercing Connector for 11 kV CC to CC (XLPE/AAAC 50-150 sqmm) for jumpering

450

-

-

... More
End Cap (push-on type) for 11 kV covered conductor ( Size : 70 -100 sqmm) for jumper ends

900

-

-

... More
Tension Jointing Kit for 11 KV Covered Conductor - 99 sqmm with insulation sleeves (compression or automatic type)

150

-

-

... More
Covered conductor, XLPE/AAAC 99 (or 100) Sq. mm.

152

-

-

... More
Back clamps of 65x65x6 mm x 300 mm length G.I Angle for holding channel

1350

-

-

... More
G.I. nuts & bolts of 16mm dia.X 40mm length.

150

-

-

... More
G.I. Pole top channel 75 X 40 X 6X 0.3 m long for S.P. structure.

450

-

-

... More
Lightning Arrester (Distribution Class) with polymer housing , 9 kV , 10 KA, with earth lead disconnector, bird protection cap and mounting brackets. MCOV : 7.65 kV or as recommended by CC manufacturer

600

-

-

... More
Insulating Piercing Connector for 11 kV CC (70-100 sqmm) to bare or insulated Al cable (16-50 sqmm) for LA

600

-

-

... More
1.1 kV , single core PVC/Al 25 sqmm cable for LA earthing including cable ties

3600

-

-

... More
LA Earthing : Safe earthing electrode Model T-19 withstanding short time current 20KA rms for 1 sec (MV) application:50 mm diameter x 2 mtrs. Electrode copper bonded & 1 bag backfill Chemical compound for soil treatement (to be installed 2 m away from structure earthing)

200

-

-

... More
Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate

250

-

-

... More
Red oxide paint @ 2 ltr/ pole

900

-

-

... More
Aluminium paint @ 1.5 ltr / pole

675

-

-

... More
G.I. Barbed Wire

900

-

-

... More
11 kV Caution Board

450

-

-

... More
Schedule G : Supply & Intsallation of Compact 3-Way RMU

-

-

-

... More
12 KV 630A 25 kA/1 sec Outdoor type (IP 54 enclosure) Motorised SF6 insulated Ring Main Unit with 02 No. 630 A Load Break Switch + 01 No. of 630 Amps Circuit breaker , one fault passage indicator complete with all accesories and controls, auxiliary power transformer, SCADA compatible and with suitable provisions to connect with future FRTU

7

-

-

... More
Safe Earthing model T-19 short current 20KA rms for 1 sec(LV / MV) application. 50 mm diameter x 3 Mtrs. Electrode & two bags backfill chemical compound.

7

-

-

... More
GI strip 35 mm x 6 mm from earth electrode to Earthing point.

140

-

-

... More
Schedule H :Supply & Intsallation of Fault Passage Indicator

-

-

-

... More
Medium Voltage Overhead Line Fault Passage Indicator (FPI), 1-phase, conductor mounting type suitable for upto 36 KV, Covered and ACSR conductors upto 20 mm dia, with built-in RF communication facility for future connection icluding all accesories as per specification (3 Units per Set/Location )

30

-

-

... More
Telescopic insulated hot stick for installation of FPI on overhead lines upto 33 kV

1

-

-

... More
Schedule I : Supply & Intsallation of 11 KV Auto-Recloser

-

-

-

... More
Three Phase outdoor 12 kV solid insulated, pole mounted Automatic Circuit Recloser (Auto-Recloser), 630 A, 12.5 KA, self powered through auxiliary supply VT or by other means complete with Controller Unit, battery and charging system, software, Auxilliary Supply VT, with pole mounting brackets, surge arrestor brackets, B&N and connectors.

10

-

-

... More
11 kV Lightning Arrestor with earth lead disconnector (Distribution Class), 9 kV, 10 KA, mounting brackets, earth bar and B&N

60

-

-

... More
UPG Clamp for ACSR conductor (50-100 Sqmm)

60

-

-

... More
LA and body earthing : Safe earthing electrode Model T-19 withstanding short time current 20KA rms for 1 sec (MV) application:50 mm diameter x 2 mtrs. Electrode copper bonded & 1 bag backfill Chemical compound for soil treatement

30

-

-

... More
G.I. Wire 8 SWG for earthing

60

-

-

... More
G.I .channel 75X40X6mmX1.8 m long

40

-

-

... More
Back clamps of 65x65x6 mm x 300 mm length G.I Angle for holding channel

80

-

-

... More
G.I. nuts & bolts of 16mm dia.X 40mm length.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.