Military Engineer Services Tender

View complete overview of Sikkim MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date17 Dec 2024
Closing Date7 Jan 2025
Tender Amount₹ 41,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for 5mm thick in CM (1:3) in ceiling finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.

86

-

-

... More
Material and labour for applying three coats of white washing including preparation of new / previously untreated surfaces of wall complete all as specified and as directed.

86

-

-

... More
M&L for applying two coats of exterior acrylic emulsion weather proof paint over a coat of primer including complete removal of existing surfaces including scafolding upto 15m height including preparation of new/old plastered surfaces etc complete all as specified and as directed.

6650

-

-

... More
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out as in soft/loose soil for foundation etc. Complete all as directed by the Engr-in-Charge.

14

-

-

... More
M&L for PCC (1:3:6), type C-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and as directed.

13.1

-

-

... More
Demolition of brick work or stone / boulder masonary or precast concrete block walling , built in cement mortar including all quoins, arches, pillars, etc but exclusing ashlar facings, dressed stoneswork and precast concrete articles complete all as direcetd.

1

-

-

... More
M&L for pre cast cement concrete block masonry with solid blocks, exc. 10 cm in width and settting in cement mortar (1:6) type C1, (1:3:6) (using 20 mm graded stone aggregate) as per IS 383 complete all as specified and as directed.

12

-

-

... More
Materials & labour for rendering 20 mm thick in cement mortar (1:4) on fair face of brick or stone masonary of wall surfaces finished surface even and smooth without using extra cement complete all as specified and as directed.

50

-

-

... More
Materials & labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of conc faces/ brick or stone masonary of wall surfaces finished surface even and smooth without using extra cement complete all as specified and as directed.

60

-

-

... More
M &L for RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in Slabs supported on walls including necessary form work complete all as specified & as directed. NOTE : Re-inforcement shall be measured and paid separately.

1.5

-

-

... More
S&F TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping of columns, hooking ends and biniding wireand including mild steelw wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.

223

-

-

... More
All as per item No 14.00 here-in-above but 5 mm and over upto and including 10 mm dia in stirrups spacersand binders complete all as specified and directed.

120

-

-

... More
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc complete all as specfied and as directed.

15

-

-

... More
S&F for Rolled sections Fe 410-w (grade E-250) quality-A as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates complete all as specified and as directed.

1670

-

-

... More
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated/Zigzag/Trapezoidal corrugation steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering fixed with self tapping screws/L type or J hooks complete all as specified and as directed.

198

-

-

... More
M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering fixed with self tapping screws /L type or J hooks complete all as specified and as directed.

42

-

-

... More
S&F powder coated GI grid frame work for false ceiling comprising of the following sections for making partition of 600x600mm size fixed to walls with rawl plugs and screws and hanged to roof with and including 1.18 mm dia GI wire suspender of suitable length and buterfly clips, size of main tee shall be 23mmx 28mmx 0.30mm thick, cross tee shall be 24x 23x .30 mm thick and wall angle shall be 20mmx20mmx0.30mm thick complete all as specified and as directed.

20

-

-

... More
S&F for 4mm thick Non asbestos fibre cement building board (E-board) of approved texture for insulation and acoustic purpose of size 595x595 mm size fixed with staples on snap grid as in ceiling complete all as specified and as directed.

20

-

-

... More
M&L for sand filling under floors including watering and consolidation complete all as specified and directed by the Engr-in-Charge.

3

-

-

... More
M&L for Hardcore of gauge n. exc. 63mm deposited spread and levelled in layers n. exc. 15 cm thick watered and rammed to true surface complete all as specified and as directed.

3

-

-

... More
M&L for Non - skid colured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.

22

-

-

... More
M&L for glazed coloured ceramic tiles (350x250x7mm thick/450x300x7mm thick) on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match the colour incl 10 mm thick screed bed/rendering of CM (1:4) as in wall complete all as specified and as directed.

14

-

-

... More
Fabrication and fixing in repairs powder coated aluminium sliding window (three track) with aluminium frame of section 62.30 x 44.50 x 1.5 mm with shutter stiles rail of aluminium section of size 47.62 x 44.45 x 1.5 mm thick including jointing cleat for fixing binder hardware glazing clips rubber packing for air lock purpose anodized aluminuim strip bearing screw etc for fixing glass pans in frame shutter covered with fully selected quality glass 4mm thick tinted/plain glass with rubber packing and locking arrangement and fly proof shutter of same size with aluminium wire mesh complete all as spcified and as directed.

4.3

-

-

... More
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer to new or previously un-treated steel surfaces of any description over 10 cm in width or girth including preparation of new steel surfaces complete all as specified and as directed.

78

-

-

... More
M&L preparation of new or previously untreated wooden surfaces of any description exc 10 cm in width and grith and applying two coats of synthetic enamel paint (1st grade in quality) over one coat of pink primer complete all as specified & as directed.

12

-

-

... More
S&F 2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.

0.08

-

-

... More
Material and labour for 35mm thick 2nd class HW plain, framed, paneled shutters (two panel) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm veneered particle board with commercial face veneering on both faces. The size of rail & stile as per IS:1003 (Part-1), Kiln, seasoned & chemically pressure, treated complete all as specified and as directed.

3.6

-

-

... More
S&F 100mm long butt hinges, medium weight, cold rolled, mild steel complete all as specified.

6

-

-

... More
S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.

4

-

-

... More
S&F 150mm long aluminum anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.

4

-

-

... More
S&F 250mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section complete all as specified and as directed.

2

-

-

... More
M&L for preparation of new plastered surfaces of walls applying two coats of distemper, oil emulsion, white or tinted over new wall surface on a coat of 3mm thick wall care putty in two layers (1.5mm each layer), complete all as specified and as directed.

40

-

-

... More
M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, parepet, plinth course including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.

1.7

-

-

... More
Demolition to cement concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.

2.2

-

-

... More
M&L for PCC (1:3:6), type C-2 (using 40mm graded stone aggregate) as in surface channels/drain including forming fair finished to drain channel complete all as specified and as directed.

4.2

-

-

... More
Demolition to cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.

4.4

-

-

... More
M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection/path etc (75mm thick) finishing the surface even & smooth without using extra cement complete all as specified and as directed.

40

-

-

... More
Material and labour for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigments in floors steps etc including 15mm thick screed bed or bedding layer in CM (1:4) complete all as specified and as directed.

52

-

-

... More
M&L for raking out joints/pointing to random rubble masonary coursed or uncoursed work in walls on edge in floors, surface channels, roofs etc complete all as specified and as directed.

7

-

-

... More
M&L for raised pointing in CM (1:4) to block in course or squared rubble coursed or uncoursed masonry or concrete block walling etc complete all as specified and as directed.

7

-

-

... More
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed.

32

-

-

... More
Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.

12

-

-

... More
Rough excavation not exceeding 1.5m deep and getting out in soft/loose soil for foundation of retaining wall complete all specified and as directed.

29

-

-

... More
Excavation over areas n.exc 1.5m deep in soft/disintegrated rock for foundation of retaining wall complete all as specified and as directed.

26

-

-

... More
M&L for plain cement concrete (1:3:6), type C-2 (using 40mm graded crushed stone aggregate) as in retaining wall etc complete all as specified and as directed.

49

-

-

... More
M&L for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, bases for columns over 1.5 metre span etc complete all as specfied and as directed.

7

-

-

... More
Use and waste of formwork to faces of walls,retaining wall etc; vertical or batter for rough finished surfaces complete all as specified and as directed.

120

-

-

... More
S&F PVC(SWR) pipe 75mm dia single socketed, in any length as in weep holes complete all as specified and directed.

35

-

-

... More
S&F for geosynthetic material 75mm dia as in weep holes cover complete all as specified and as directed.

32

-

-

... More
M&L for hand packing using Broken stone or boulders (any thickness) at back of block masonry retaining wall and raising (or lowering) to the required level complete all as specified.

9

-

-

... More
M&L for rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar (1:4) finished even & smooth without using extra cement complete all as specified and as directed.

38

-

-

... More
M&L for applying two coat of white wash including preparation of previously untreated surfaces of walls complete all as specified and as directed.

38

-

-

... More
Excavating in post holes (or similar holes) each n.exc 0.5 Cum getting out and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified and as directed.

12

-

-

... More
M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregates) on in foundation, filling and mass concrete complete all as specified and as directed.

1.5

-

-

... More
M&L for 25 mm thick PCC (1:2:4) type B1 ( 20mm graded stone aggregate) , finished concrete surfaces even and rough to receive floor finishes complete all as specified and as directed.

32

-

-

... More
S&F PVC (SWR) pipes, half round 150mm bore with rounded edges including all accessories like bend `T' etc for eaves gutter complete complete all as specified and as directed.

32

-

-

... More
S&F 110mm bore, PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or under floors , fixed on walls with necessary clips complete all as specified and as directed.

12

-

-

... More
S&F for 110 mm bore PVC (SWR) bends in any radius complete all as specified and as directed.

2

-

-

... More
E/M Portion Material & Labour for point wiring with 1.50 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable of working voltage 1100 volts grade conforming to IS-694 Pt I & II of 2000 drawn through and including non metallic rigid PVC medium grade conduit and conduit accessories (ISI) Marked concealed in wall/fixed to roof, ceiling etc., including provision of 1.5 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable as earth continuity conductor, fabricated sunken terminal box made out of 1.60mm thick sheet steel painted, concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc., connected to main switch / DBs or common earth dolly for light point/ fan point/ exhaust fan point/ call bell point/ controlled by one switch 5/6 Amp one way complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.

7

-

-

... More
All as per item No 62.00 here-in-above but, one socket outlet, three pin, 5/6 Amp on the same board with other switches complete all as specified and as directed.

1

-

-

... More
All as per item No 62.00 here-in-above but, one three pin 5 Amp switch socket outlet point on independent board complete all as specified and as directed.

3

-

-

... More
All as per item No. 62.00 here-in-above but for 15/16Amp switch socket out let, independent with 2.5 sqmm copper cable of PVC insulated, unsheathed, multi stranded and 2.5 Sqmm for earth continuity conductor, complete all as specified and as directed.

2

-

-

... More
Supply and fixing of switch paino, flush type, single pole, one way, 5/6 Amp, (ISI marked) complete all as specified & as directed.

11

-

-

... More
S&F socket outlet 2 in 1, three pin, 6 Amp 230 volts, 50Hz, ISI marked complete all as specified and as directed.

3

-

-

... More
Supply and fixing of switch paino, flush type, single pole, one way, 16 Amp, 230 volts, 50Hz (ISI marked) complete all as specified & as directed.

2

-

-

... More
S&F socket outlet 2 in 1, three pin, 16 Amp flush type 230 volts, 50Hz, (ISI marked) complete all as specified and as directed.

2

-

-

... More
S&F ceiling rose, PVC/Polycarbonate insulated body, 3 terminal and 240 volts (ISI marked) complete all as specified and as directed.

2

-

-

... More
Supply and fix in repair of 20 W LED tubelight fitting with lamp,Extruded aluminium, PC Diffuser, efficiency 125 lm/ W, glare free, THD10%,Potted electronic driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Make-Crompton cat part CCS-100-20-65-HLL-OP-NWH / Havells cat part No. ENDURALINEARPROBS20WLED 865SPCSSIND/ Philips cat part No. BN170C LED20S-6500 PSU L120

2

-

-

... More
Supply and fix aesthetically designed 2X2 LED flat panel for ceiling mounting which provides soft light and glare free illumination not less than 36 watt,efficiency 125 lm/ W, including and connecting up all as specified and as directed. Make: Crompton cat part TCR-145-36-65-SL-NWH, Havells cat Part No. VENUSNEO2x2PLR36WLED865PO, Philips Cat part No. RC360B LED 36S-6500 V1 L60W60 PSU OD.

4

-

-

... More
S&F LED lights fittings 1x9/1x10 W 220 V, AC bulk head luminaries including holder including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.

1

-

-

... More
Supply and laying of DWC pipe,ISI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket,bend,couplers etc confirming to IS 14930,part-II complete with fitting cutting,jointing etc of size 40 mm outer dia complete all as specified and as directed by Engr-in-Charge

35

-

-

... More
Supply, laying, jointing and testing XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.

40

-

-

... More
S&F 250mm sweep exhaust fan PVC body model, 240 Volts, AC 50 Hz, with all accessories such as louvers, three core single core PVC insulated copper conductor of size 0.5Sqmm from ceiling rose to fan, complete all as specified and as directed.

1

-

-

... More
S&F MCB DB SPN 8 Ways double door, IP-42, IK-09 with metal door, rated bus bars, earth bar, neutral links complete incl blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed.

1

-

-

... More
S&F MCB single pole & neutral 32 to 63 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
S&F MCB single pole 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity, 'C' Curve complete all as specified and as directed by Engineer-in-charge.

6

-

-

... More
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber & RCC (1:2:4) type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel as per SSR part-I complete all as specified and as directed. Note- Earthwork,strip protection,strip upto 7.5 meter are also included in quoted rate.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.