Energy And Power Department Tender

View complete overview of Sikkim Energy And Power Department Tender

Energy And Power Department Tender

Works
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Sep 2019
Closing Date5 Nov 2019
Tender Amount₹ 6,42,93,773 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
a) 3C x 150sq.mm. EPKT 3111 (indoor type).

2

-

12540

... More
b) 3C x 150sq.mm. EPKT 3372 (outdoor type).

2

-

18122.4

... More
3C x 150sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

4

-

35044.8

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

1392

-

634.8

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

1380

-

419

... More
CONVERSION OF H.T LINES INTO UNDERGROUND CABLE SYSTEM OF RAJ BHAVAN AND SURROUNDING AREAS, GANGTOK IN EAST SIKKIM.

-

-

-

... More
3 x 95sq.mm.11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

900

-

2048.4

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3-core XLPE(Raychem make or equivalent).

-

-

-

... More
a) 3core 95sq.mm. EPKT 3111 (indoor type).

2

-

10478.4

... More
b) 3core 95sq.mm. EPKT 3362 (outdoor type).

2

-

16940.4

... More
3core x 95 sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

2

-

27547.2

... More
150sq.mm. Aerial Bunched Cable, 11KV grade 3-core aluminum conductor.

600

-

2032.8

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

876

-

634.8

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

800

-

419

... More
MODERNIZATION AND UPGRADATION OF L.T DISTRIBUTION SYSTEM OF RAJ BHAVAN AND SURROUNDING AREAS, GANGTOK IN EAST SIKKIM.

-

-

-

... More
1.1 KV PVC/XLPE insulated heavy duty power cables for working voltage upto & including 660/1100 Volts. CONF to IS:7098(Part-I) with latest amendment Aluminium conductor.

-

-

-

... More
a) 3.5 x 240 sq.mm.

700

-

2556

... More
b) 3.5 x 150 sq.mm.

900

-

1610.4

... More
c) 3.5x95sqmm

300

-

1102.8

... More
d)3C x 25 sqmm

900

-

410.4

... More
e)3.5 x 16 sqmm

900

-

276

... More
LT 1.1 KV Straight through joint termination kit for PVC/XLPE cables 2,3 & 1/2 core (Dension)

-

-

-

... More
a) 3.5 x 240 sq.mm.

4

-

2449.2

... More
b) 3 x 150 sq.mm.

6

-

1831.2

... More
L.T.distribution switch board,outdoor/indoor type 800 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls: Incoming: 1 No 800Amp, 415V, FP,manually draw out type ACB with built in thermo magnetic release and 6 NO+6NC auxiliary contacts. Outgoing: 3 Nos 200Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release: -1No. 100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release , 1No.100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release.

3

-

299306.4

... More
L.T.distribution switch board,outdoor/indoor type 400 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls: Incoming:1 No 400Amp, 415V, FP MCCB breaking capacity 50KA with built in thermo magnetic release Outgoing: 1 No 200Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,3 No. 100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,1 No 63Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release

4

-

131503.2

... More
L.T.distribution switch board,outdoor/indoor type 200 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls: Incoming:1 No 200 Amp, 415V, FP MCCB breaking capacity 50KA with built in thermo magnetic release Outgoing: 2No 100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,1 No. 63 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,1 No. 32 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release having relay setting 16-25A.

12

-

95432.4

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

19

-

11803.2

... More
Copper wire 8 SWG

95

-

763.2

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

1860

-

634.8

... More
75mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

1740

-

308.4

... More
Placement of L.T. distribution board on parapet of size 2x0.61x 0.35x.0.61mtrs in 1:3:6 cc mix including 12mm thick cement plaster in 1:4mix materials.

19

-

1713

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

3500

-

419

... More
CONVERSION OF 11KV OVERHEAD TRANSMISSION LINE TO UNDERGROUND CABLE SYSTEM FROM 66/11 KV BULBULAY CONTROL ROOM TO 11/11 KV OLD CANTT.CONTROL ROOM , GANGTOK IN EAST SIKKIM.

-

-

-

... More
3 x 300 sq.mm.11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

1970

-

4348.8

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3-core XLPE(Raychem make or equivalent).

-

-

-

... More
a) 3core 300sq.mm. EPKT 3121 (indoor type).

2

-

13377.6

... More
b) 3core 300sq.mm. EPKT 3372 (outdoor type).

2

-

20376

... More
3C x 300 sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

5

-

38328

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

1950

-

634.8

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

1900

-

419

... More
INSTALLATION OF ADDITIONAL 11 KV VCB PANELS FOR POWER EVACUATION AT 66/11KV BULBULAY CONTROL ROOM AND 11/11 KV RAJBHAVAN CONTROL ROOM, GANGTOK IN EAST SIKKIM.

-

-

-

... More
11 KV VCB Panels.

-

-

-

... More
630A, 20KA indoor horizontal isolation, horizontal draw outs complete with vaccum interupters, motor/manual operated spring charger mechanism, trip closing coils, 4NO + 4NC Aux contacts, anti pumping devices, mechanical trip close switches, mechanical counter and mechanical spring position indicator, suitable 3 core CTs having class 1/5P10/PS accuracy static/solid type 2 Nos. O/C + 1 No. E/F relays, alarm annunciation etc. Make: Siemens/Kirloskar or equivalent conforming to latest IS Specification.

3

-

611110.8

... More
DC EQUIPMENTS.

-

-

-

... More
Battery Bank: Sealed and maintenance free lead acid battery of 200 AH capacity of 55Nos.x2 Volt each with terminal voltage of 110V complete with accessories of make Amaraja/Exide or equivalent make.

1

-

146666.4

... More
110 Volt, 200 AH Battery Charger set having facility for both trickle & boost charging complete with necessary protection & other instruments of Amaraja make or equivalent make.

1

-

248822.4

... More
CONTROL CABLES

-

-

-

... More
4 x 2.5sq.mm. 1.1KV grade heavy duty PVC insulated sheathed copper conductor cable armoured.

200

-

183.6

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & two bag backfill chemical compound.

4

-

11803.2

... More
Copper wire 8 SWG

20

-

763.2

... More
INSTALLATION OF 500 KVA PACKAGED SUB-STATION AT MINTOKGANG, GANGTOK IN EAST SIKKIM.

-

-

-

... More
500KVA Packaged Sub-Station complete

1

-

1920000

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

3

-

11803.2

... More
Copper wire 8 SWG

15

-

763.2

... More
Construction of parapet for installation of above transformer 0.61x0.61x0.153 mtrs. in 1:3:6 cc i/c 12 mm cement plaster of parapet in 1:4 mix.

1

-

10000

... More
DRAWING OF 11KV DEDICATED TRANSMISSION LINE ON UNDERGROUND CABLE SYSTEM FROM MLA HOSTEL TO MINTOKGANG, GANGTOK IN EAST SIKKIM.

-

-

-

... More
11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

-

-

-

... More
a) 3 x 95sq.mm.

800

-

2048.4

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3-core XLPE(Raychem make or equivalent).

-

-

-

... More
a) 3core 95sq.mm. EPKT 3101 (indoor type).

2

-

10478.4

... More
b) 3core 95sq.mm. EPKT 3352 (outdoor type).

2

-

16940.4

... More
3C x 95 sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

2

-

27547.2

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

780

-

634.8

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

750

-

419

... More
DRAWING OF 11KV DEDICATED TRANSMISSION LINE ON UNDERGROUND CABLE SYSTEM FROM 11/11 KV TNA CONTROL ROOM TO MINTOKGANG, GANGTOK IN EAST SIKKIM.

-

-

-

... More
3 x 95sq.mm.11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

500

-

2048.4

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3-core XLPE(Raychem make or equivalent).

-

-

-

... More
a) 3core 95sq.mm. EPKT 3101 (indoor type).

2

-

10478.4

... More
b) 3core 95sq.mm. EPKT 3352 (outdoor type).

2

-

16940.4

... More
3C x 95 sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

2

-

27547.2

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

480

-

634.8

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

450

-

419

... More
MODERNIZATION AND UPGRADATION OF L.T DISTRIBUTION SYSTEM OF MINTOKGANG AREAS, GANGTOK IN EAST SIKKIM.

-

-

-

... More
1.1 KV PVC XLPE Insulated Heavy Duty Power Cables for working voltage upto & including 660/1100 Volts CONF. To IS 7098 (Part-1) with latest amendment Aluminium Conductors.

-

-

-

... More
3.5 core x 95 sqmm

350

-

1102.8

... More
3.5 core x 50 sqmm

300

-

638.4

... More
3.5 core x 35 sqmm

250

-

482.4

... More
3 core x16 sqmm

250

-

276

... More
3.5 core x 25 sqmm

250

-

410.4

... More
L.T.distribution switch board,outdoor/indoor type 400 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls:

-

-

-

... More
Incoming:1 No 400Amp, 415V, FP MCCB breaking capacity 50KA with built in thermo magnetic release Outgoing: 1 No 200Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,3 No. 100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,1 No 63Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release

3

-

131503.2

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

3

-

11803.2

... More
Copper wire 8 SWG

15

-

763.2

... More
Alumnium Thimble.

-

-

-

... More
95 sqmm

16

-

15.6

... More
50 sqmm

16

-

9.6

... More
35 sqmm

16

-

6

... More
25 sqmm

16

-

6

... More
16 sqmm

16

-

3.6

... More
PVC Tape

20

-

18

... More
90mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

612

-

408

... More
50mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

712

-

123.6

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

1300

-

419

... More
Placement of L.T. distribution board on parapet of size 2x0.61x 0.35x.0.61mtrs in 1:3:6 cc mix including 12mm thick cement plaster in 1:4mix materials.

3

-

1713

... More
DRAWING OF 11 KV TRANSMISSION LINE FROM 11/11 KV TASHILING CONTROL ROOM INCLUDING SYSTEM IMPROVEMENT AND UPGRADATION OF L.T. DISTRIBUTION SYSTEM OF POWER SECRETARIAT, GANGTOK IN EAST SIKKIM.

-

-

-

... More
500KVA Packaged Sub-Station complete

1

-

1920000

... More
11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

-

-

-

... More
a) 3 x 50 sq.mm.

900

-

1444.8

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3-core XLPE(Raychem make or equivalent).

-

-

-

... More
a) 3core 50sq.mm. EPKT 3101 (indoor type).

2

-

10488

... More
b) 3core 50sq.mm. EPKT 3362 (outdoor type).

2

-

16876.8

... More
3C x 50 sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

3

-

27547.2

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

780

-

634.8

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

8

-

11803.2

... More
Copper wire 8 SWG

40

-

763.2

... More
L.T.distribution switch board, indoor type Kiosk,63 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter,indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket and & locking arrangement complete with following incoming / outgoing controls: Incoming: 1No. 63 Amp, 415V, FP MCCB breaking capacity 25KA with built in thermo magnetic release. Outgoing: 2Nos. 63 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release having relay setting 16-25A. 1No.32 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release.

5

-

61375.2

... More
P.V.C. 3&1/2 core, 1.1KV grade, 240sq.mm.aluminium cable.

60

-

2916

... More
P.V.C. 3&1/2 core, 1.1KV grade,185sq.mm.aluminium cable.

60

-

1998

... More
P.V.C. 3&1/2 core, 1.1KV grade,70sq.mm.aluminium cable.

300

-

836.4

... More
P.V.C. 3&1/2 core, 1.1KV grade,50sq.mm.aluminium cable.

300

-

638.4

... More
P.V.C. 3&1/2 core, 1.1KV grade, 35sq.mm.aluminium cable.

400

-

482.4

... More
P.V.C. 3&1/2 core, 1.1KV grade, 25sq.mm.aluminium cable.

400

-

410.4

... More
1.5 sqmm PVC insulated type copper conductor wire in suitable dia PVC conduit type.

40

-

1982.4

... More
2.5 sqmm PVCinsulated type copper conductor wire in suitable dia PVC conduit type.

45

-

3068.4

... More
4 sqmm PVCinsulated type copper conductor wire in suitable dia PVC conduit type.

18

-

4622.4

... More
6sqmm PVCinsulated type copper conductor wire in suitable dia PVC conduit type.

15

-

7198.8

... More
Cable end box for following L.T. cables

-

-

-

... More
a) 3&1/2 core, 240sq.mm.

2

-

700.8

... More
b) 3&1/2 core, 185sq.mm.

4

-

565.2

... More
c 3&1/2 core, 70sq.mm.

4

-

398.4

... More
d) 3&1/2 core, 50sq.mm.

4

-

339.6

... More
e) 3&1/2 core, 35sq.mm.

4

-

339.6

... More
f) 3&1/2 core, 25sq.mm.

4

-

316.8

... More
75mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex)

1200

-

308.4

... More
20A S.S. Combined with box.

320

-

147.6

... More
Switch 5 Amp.(NOA)

100

-

18

... More
20Amp 3-pin Socket

100

-

68.4

... More
Post top lantern suitable for compound lighting complete with bulb.(Philips/Bajaj or equivalent Make)

9

-

3508.8

... More
VTPN DB with DPX 125MCCB as incomer, 12 way,Double Door. Legrand Make or equivalent

22

-

23680.8

... More
Incomer 125A, 4pole, 25Ka breaking capacity, MCCB, Legrand Legrand Make or equivalent

22

-

15750.24

... More
MCB 63A, (DP)

120

-

915.6

... More
MCB 63A, (SP)

60

-

428.4

... More
MCB 40A, (DP)

60

-

774

... More
MCB 32A, (SP)

120

-

170.4

... More
Loadstar isolator, SPN 100A, Legrand Make or equivalent

8

-

907.2

... More
Chandlier

1

-

9883.2

... More
PVC casing bit D/L

650

-

30

... More
Casing Accessories.

36

-

38.4

... More
Sunmica board

45

-

37.2

... More
PVC Tape.

30

-

18

... More
150W LED Flood Light

6

-

31184.4

... More
Construction of parapet for installation of above transformer 0.61x0.61x0.153 mtrs. in 1:3:6 cc i/c 12 mm cement plaster of parapet in 1:4 mix.

1

-

10000

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

1000

-

419

... More
CONVERSION OF 11 KV OVERHEAD TRANSMISSION LINE TO UNDERGROUND CABLE SYSTEM FROM 11/11 KV OLD CANTT. CONTROL ROOM TO VIP COLONY, GANGTOK IN EAST SIKKIM.

-

-

-

... More
11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

1700

-

2648.4

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3CXLPE(Raychem make or equivalent).

-

-

-

... More
a) 3C x 150sq.mm. EPKT 3111 (indoor type).

4

-

12540

... More
b) 3C x 150sq.mm. EPKT 3372 (outdoor type).

4

-

18122.4

... More
3C x 150sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

4

-

35044.8

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

1660

-

634.8

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

1600

-

419

... More
SEGREGETION OF L.T DISTRIBUTION SYSTEM OF VIP COLONY,GANGTOK IN EAST SIKKIM.

-

-

-

... More
1.1 KV PVC/XLPE insulated heavy duty power cables for working voltage upto & including 660/1100 Volts. CONF to IS:7098(Part-I) with latest amendment Aluminium conductor.

-

-

-

... More
a) 3.5 x 240 sq.mm.

500

-

2556

... More
d)3.5 x 25 sqmm

300

-

410.4

... More
LT 1.1 KV Straight through joint termination kit for PVC/XLPE cables 2,3 & 1/2 core

-

-

-

... More
a) 3.5 x 240 sq.mm.

4

-

2449.2

... More
L.T.distribution switch board,outdoor/indoor type 200 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls:

-

-

-

... More
Incoming:1 No 200 Amp, 415V, FP MCCB breaking capacity 50KA with built in thermo magnetic release Outgoing: 1 No 63 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,1 No. 32 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release.

4

-

103232.4

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

4

-

11803.2

... More
Copper wire 8 SWG

20

-

763.2

... More
50mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex) for both H.T. & L.T.cables

270

-

134.4

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

470

-

634.8

... More
Placement of L.T. distribution board on parapet of size 2x0.61x 0.35x.0.61mtrs in 1:3:6 cc mix including 12mm thick cement plaster in 1:4mix materials.

4

-

1713

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

700

-

419

... More
DRAWING OF 11 KV DEDICATED TRANSMISSION LINE ON UNDERGROUND CABLE SYSTEM FROM 11/11 KV TNA CONTROL ROOM TO HIGH COURT GANGTOK IN EAST SIKKIM.

-

-

-

... More
3 x 50 sq.mm. 11KV (E) stranded compact circular aluminium conductor screened with extruded semiconductering compound, XLPE insulated, insulation screened with extruded semiconductering compound in combination with copper tape (0.3KA for 1Sec) cores laid up inner shearthed (ST-2 PVC) galvanised steel strip armoured and overall PVC sheathed (ST-2 PVC) black cable confirming to IS 7098/11/85 with latest amendments.

900

-

1444.8

... More
Heat shrinkable end termination kit for 6.6KV(UE)/11KV (E) 3-core XLPE(Raychem make or equivalent).

-

-

-

... More
a) 3core 50sq.mm. EPKT 3101 (indoor type).

2

-

10488

... More
b) 3core 50sq.mm. EPKT 3362 (outdoor type).

2

-

16876.8

... More
3C x 50 sq.mm. Heat shrinkable St. Through jointing kit for 11KV (E) 3-core XLPE(Kit No. EPKJ-3115-3118) (Raychem make or equivalent).

2

-

27547.2

... More
110mm Rigid PVC pipe as per IS 4985-2000 working pressure 6kgf/cm2 (Finolex).

870

-

634.8

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

4

-

11803.2

... More
Copper wire 8 SWG

20

-

763.2

... More
P.V.C. 3&1/2 core, 1.1KV grade, 240sq.mm.aluminium cable.

60

-

2916

... More
P.V.C. 3&1/2 core, 1.1KV grade,185sq.mm.aluminium cable.

60

-

1998

... More
Excavation of 0.45x0.90x1.00m cable trench in mix soil & re-filling with available excavation earth and providing cement concrete on the top of the trench.

850

-

419

... More
INSTALLATION OF 11/11KV RMU (RING MAIN UNIT) AT HIGH COURT, GANGTOK IN EAST SIKKIM.

-

-

-

... More
7 Way RMU outdoor type with provisions of 2Nos on load isolators and 3 Nos Circuit breakers

1

-

1200000

... More
Plinth works for installation of RMU.

1

-

12000

... More
Safe earthing for model T-19 short tme current 20 KA rms for 1 sec (LV/MV) application- 50 mm dia x 2 mtrs electrode and one bag backfill chemical compound

1

-

11803.2

... More
Copper wire 8 SWG

5

-

763.2

... More
Fencing.

1

-

32000

... More
REPLACEMENT OF 500KVA OIL TYPE TRANSFORMER WITH 500KVA DRY TYPE INDOOR TRANSFORMER AND ALLIED WORKS AT HIGH COURT OF SIKKIM, GANGTOK IN EAST SIKKIM.

-

-

-

... More
500KVA,11/0.43KV,Copper Wound, 50Hz,Dyn-11, Dry type, distribution transformer

1

-

1110000

... More
L.T.distribution switch board,outdoor/indoor type 800 Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls: Incoming: 1 No 800Amp, 415V, FP,manually draw out type ACB with built in thermo magnetic release and 6 NO+6NC auxiliary contacts. Outgoing: 3 Nos 200Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release: -1No. 100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release , 1No.100 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release.

1

-

299306.4

... More
11KV, 3pole, 400amps Air Break GOS tilting type, three insulatore per phase compl with all fittings and confirming to IS 9920 & IS 9921 Raychem RPG make .

1

-

18840

... More
11KV 3 pole 400amps DOF fuse unit compl with all fittings and confirming to IS 9920 & IS 9921 Raychem RPG make .

1

-

12057.6

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

4

-

11803.2

... More
Copper wire 8 SWG

20

-

763.2

... More
Placement for 500 KVA distribution transformer on parapet of size 1.5x1.5x1mtr. In 1:3:6cc mix including 12mm thick cement plaster in 1:4mix

1

-

8031

... More
Placement of L.T. distribution board on parapet of size 2x0.61x0.35x.0.61mtrs in 1:3:6 cc mix including 12mm thick cement plaster in 1:4mix materials except erection & transportation).

1

-

1713

... More
REPLACEMENT OF 63KVA OIL TYPE TRANSFORMER WITH 63KVA DRY TYPE INDOOR TRANSFORMER AND ALLIED WORKS AT AG OFFICE, GANGTOK IN EAST SIKKIM.

-

-

-

... More
63KVA,11/0.43KV,Copper Wound, 50Hz,Dyn-11, Dry type, distribution transformer

1

-

362234.4

... More
L.T.distribution switch board,outdoor/indoor type 100Amp, having electrolytic annealed copper bus-bar 50 x 12 mm for phase and 50 x 6 mm for neutral circuits mounted on glazed procelain or bakelite base & fitted with voltmeter, ammeter, phase selector switches,electronic KWHr meter, indicating lamps, cabin light, fabricated with 12 gauge M.S. plain sheet, painted with anti rust primer & two coats of Epoxy paint of sade 631 as per IS;5, front opening doors with gasket & locking arrangement complete with following incoming / outgoing controls: Incoming:1 No 100 Amp, 415V, FP MCCB breaking capacity 50KA with built in thermo magnetic release Outgoing: 2 No 63 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release,1 No. 32 Amp TP MCCB breaking capacity 35KA with built in thermo magnetic release.

1

-

69480

... More
Safe Earthing with T-19 short time current 20KA rms for 1sec(LV/MV) application with 50mm dai.x 2mtrs Electrode & one bag backfill chemical compound.

4

-

11304

... More
Copper wire 8 SWG

20

-

763.2

... More
Placement for 63 KVA distribution transformer on parapet of size 1.2x1.2x1mtr. In 1:3:6cc mix including 12mm thick cement plaster in 1:4mix

1

-

5429

... More
Placement of L.T. distribution board on parapet of size 2x0.61x0.35x.0.61mtrs in 1:3:6 cc mix including 12mm thick cement plaster in 1:4mix materials except erection & transportation).

1

-

1713



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.