Western Dedicated Freight Corridor Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 7,29,300Document Cost
₹ 11,800Tender Fee
Refer Documents
Summary
Repairing, Refixing /replacement & Maintenance Of Signalling And Telecommunication Gears/equipment
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
DFC-JP-SNT-MT-REJN-KSGN-9-WDFC FIELD UNIT-JAIPUR-S AND T/WDFCTender No
DFC-JP-SNT-MT-REJN-KSGN-9Tender Authority
Western Dedicated Freight Corridor ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Laying of S&T cables of various cores/pairs/quads in trenches/GI Pipes/RCC ducts/ DWC Pipes/Trunking etc ,laying of OFC ducts in trenches including laying of cables in track crossings and road crossings. It includes placing of half cut DWC pipes, pre-fabricated ducts and DWC pipes. It also 4 includes provision of labels on each cable of coloured plastic adhesive tapes or any other identifiable marker to give the cable number at each termination point G.P. The contractor will do meggering of all the cables (main & tail)before laying as well as after laying under the supervision of engineer incharge. Meggering test report of each cable will be signed jointly by authorized site representative of contractor and site engineer incharge. Note: The length of the cables laid will include the length of the cables which have been coiled for termination purposes. Half cut DWC pipes, prefabricated ducts and DWC pipes shall be supplied by DFCCIL.
10500
6
67830
... More
Cement concrete work for miscellaneous items in ratio 1:3:6. Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor.
10
3441
34419.4
... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 6 cement and sand mixture both sides of bricks with thickness 20 mm each end with contractor's own 'B' Class bricks. It also includes excavation, curing, grouting, bolting etc. where ever required. 'B' Class bricks, sand and cement (ISI mark) will be supplied by the Contractor.
20
1715
34304.8
... More
Supply, preparation, splicing and installation of straight joint for 24 fibers along with enclosures with heat shrinkable splice protection sleeve as per TEC Specn.G/OJC-02/01 March- 99 or latest. Splice losses in no case should be more than 0.1 dB.
75
15217
1141312.5
... More
Supply, preparation, splicing and installation of straight joint for 48 fibers along with enclosures with heat shrinkable splice protection sleeve as per TEC Specn.G/OJC-02/01 March- 99 or latest. Splice losses in no case should be more than 0.1 dB.
75
17367
1302567
... More
Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per approved standard and instructions of site Engineer.
6
9108
54652.5
... More
Repairing of Single case foundation by excavation and casting it with contractor's 10 cement, brick and other materials as per Drawing No. 6-AL-TYP-CW-8006 with latest amendment if any, and as per scope of work. Contractor has to completely break the entire foundation retaining the existing MS frame. The entire work shall be executed by the contractor to the Satisfaction of Site Engineer.
20
2503
50076
... More
Repairing of half case foundation by excavation and casting it with contractor's 11 cement, brisk and other materials as per Drawing No. 6-AL-TYP-CW-8005 with latest amendment if any, and as per scope of work. Contractor has to completely break the entire foundation retaining the existing MS frame. The entire work shall be executed by the contractor to the Satisfaction of Site Engineer.
20
2503
50076
... More
Replacement of old signal unit /signal route of main signal. This would include 12 releasing of old unit from top of signal post erection and mounting of new signal unit over the post including wiring of Main Signal LED/Signal route of main signal as per Technical Specification. This also includes bringing new signal unit from station/IMD/IMSD to site and bring back old unit from site to station/IMD/IMSD.
10
949
9499.3
... More
Refixing of electrical point machines and ground connection. This would include 13 removal of old /existing point machine and fixing of new/overhauled motor. This would also include bringing the new machines from station / IMD/IMSD to site and taking the old / released machines from site to station/ IMD/IMSD.
20
3338
66768
... More
Lettering/Numbering of Signals, Point Machine, Track Lead junction Boxes, Block joints, Apparatus Cases etc. (each item to be taken as One Unit). This work will be carried out as per the standard practice or as per site incharge instructions.
1240
78
97079.6
... More
Painting of two coats of synthetic enamel paint over one coat of primer on the below mentioned items at Sr. no. 151,152, 153 & 154 after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. The paint and primer should be from Asian Paints/Nerolac/Dulux/Berger. The primer/enamel paints (Aluminium synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970)/ (IS 2932 of 1974).
-
-
15
... More
Jointing of 4/6 quad/Signaling cable with Heat Shrinkable straight through Jointing Kit. 16 All the material required for the work are to be arranged by contractor himself at his own cost except Thermo Shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with DFCCIL Engineer. If any defect or any damage is observed during jointing, the contractor has to redo the joint free of cost.
30
2013
60413.4
... More
Strengthening of foundation of signals, Full/Half location boxes, by carrying out earth 17 work around the foundation, ramming of refilled earth, carrying out masonry work from bottom of earth work using country stones & cement masonry to prevent the earth from slipping down the bank. This also includes the supply of required masonry materials.
250
1438
359505
... More
Shifting and installation of Apparatus Case Single (Full) Drawing No.- 6/BL/TYP/CW/8024/0 with latest amendment, if any.
15
2836
42542.7
... More
Shifting and installation of Apparatus Case (Half) Drawing No.- 6/BL/TYP/CW/8023/0 with latest amendment, if any.
20
1870
37416
... More
Demounting and Replacement of Wheel Sensor (Track Device) of Multi-Section Digital Axle Counter (MSDAC) including disconnection and reconnection of tail cable at TLJB. This includes complete removal of Wheel Sensor (mounted on the rail) along with the tail cable under the rail. The 20 Contractor shall ensure the proper alignment of the Wheel Sensor at the time of mounting the new Wheel Sensor. Wheel sensor shall be supplied by DFCCIL. The Contractor shall bring the new wheel sensor from station / IMD/ IMSD to site and shall take the old / released wheel sensor from site to station/ IMD/ IMSD. The work shall be completed as per OEM's guidelines and Technical Requirement & Specification under the supervision of DFC site in charge.
150
1892
283903.5
... More
Installation, erection and wiring of CLS unit, Post, Ladder & Base, LED unit including 21 laying out of Tail Cable from Location box. Wiring of CLS unit shall be carried out as per Technical Specification. This also includes Protection of unit from Rainwater. The Material shall be supplied by DFCCIL.
10
3849
38497.4
... More
Installation, erection and wiring of Junction Type/'V' Type route Indicator (LED Type)/seven Segment Route display unit. Wiring shall be carried out as per Technical Specification. This also includes Protection of unit from Rain Water. The Material shall be supplied by DFCCIL
12
925
11105.64
... More
Installation, erection of Shunt Signal Units with base & post and laying out of tail cable from location box and Wiring of Shunt Signal LED unit as per Technical Specification. This also includes Protection of unit from Rain Water. The Material shall be supplied by DFCCIL. 24
16
883
14137.28
... More
Cross Trench for identification of the route of existing signaling and telecom cables.
600
257
154566
... More
Dismantling and releasing of location boxes/Apparatus Cases/jn. Boxes which includes releasing of terminal boards, relays, terminals, batteries track feed chargers and other associated fitting installed in the locations 26
20
756
15128.8
... More
Main Signal foundation. 27
10
9651
96515.2
... More
Shunt Signal Foundation 28
15
3232
48491.25
... More
Location Box foundation (Half Case) 29
15
6263
93956.1
... More
Location Box foundation (Full Case)
20
8204
164096.2
... More
Supply and Installation of earth electrode assembly as per latest RDSO standard / 30 DFCCIL site in charge instruction. This also includes fixing of earth electrodes, earthing of S&T apparatus cases along with all equipment and cable armours along with soldering at all location as decided by the site engineer of the DFC, signal post etc. connected through cable/GI wire 8SWG supported on MS flat size 5mmX40mm to earth electrode as per DFCCIL drawing and practice on the division suitable brick masonry enclosure to be provided around the earth. The earth value which should be less than 10 ohms including the lead wire, should be measured and painted on it. (Inspection by Consignee).
50
2823
141184.5
... More
Supply of Round head type, glass fuses per Spec No IRS: S -78/92 with latest amendments,0.6A/2A/4A/6A/8A/10A rating capacity
3000
10
32790
... More
Execution of Maintenance activities of Electrically Operated Points as per Maintenance Schedule (Annexure-D)
-
-
22353939.36
... More
Execution of Maintenance activities of MSDAC, Color light signals, Cables, Location Boxes etc. as per Maintenance Schedule (Annexure-D) Per Level
-
-
49969890.72
... More
Provision of multi-tasking staff/Helper to carry out different Maintenance Activities as per Annexure-A(Educational Qualification and Experience Requirement As per Annexure-B)
38325
968
37112397
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%