Urban Improvement Trust Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Urban Improvement Trust - UIT Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Mar 2025
Closing Soon19 Mar 2025
Tender Amount₹ 24,93,000 
Notes
Download

Costs

  • EMD

    ₹ 49,860
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Suppl and Installation of spike of M.5. rod 20mm dia 3.0mtr.Jong for earthing of (tower/pole) drive into earth by mechanicalmeans sturcture connection the spike with cross arm top hamperPCC pole, lattics tower to earth etc. complete as per technicalspecification of DISCOM

35

1819

63665

... More
SITC of IP-42 and general construction confirming 15:8623: 1993, wal/ freestanding floor mounted to dust and vermin proof compartmentalised cubical panelas specifications and Other parameters required as per point (a) (b), (c) (d), (e).(f), (gl. (h) as below:-(a) Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments havingconcealed hinged type doors with key type lock with/without detachableextension type structure. Removable 3 mm. thick sheet steel gland plates withappropriate size of knockouts for cabies shall be provided(b)complete panel shall undergo a process of degreasing Water rinsing Activation, derusting, pickling in acid bath, phosphatising & shall be subjecmicrons on both side of panel. The panel having PE foam/ Neoprene rubbergasket of not less than 3mm thickness required hardware concealed hingeddoor with key type locking arrangement for equipment/switchgear earthed with2.5 sq.mm braided copper wire. (c) Interconnection between bus bar and switchgears /cable shall be rigidlysupported and made out by flexible copper wires (up to 63 amp and by solid busbar (63 amp). control wiring will be carried out with 1.5 Sq/mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints /interconnections of copper bus bar shall be dully tinned. Clearance betweenmain bus bar and risers/metal parts shall be at least 10 mm additional to wicthleeves. Earth and Neutral busbar shall be half of the size of phase bus bar. (Cost of Dus bar/Flexible wire forinterconnection between Main busbar and Switchgear is to be Paid Extra (d)Wiring between components within switchgear and Incoming/outgoing cableshall be done through the terminal block only. Direct connection shall not bepermitted. Each terminal block shall be one piece moulded, barrier type, 650 voltgrade, complete with washers, heads, studs with two nuts and identification stripsand shall have adequate continuous current rating, for tap-offs, adjacentterminals with shorting strips shall be used. 10% Spare terminal blocks shall beprovided. Wire identification or marking strip shall correspond to the designationof the wiring diagrams. All wire terminals on the equipment shall also be markedith designation corresponding to those of the wiring diagram.je All wiring shall be enclosed in plastic channels and neatly bunched and closedin metering chamber, Wiring between terminals of various devices shall be 'pointto point' (no wire splitting or tee connectons) with wires neatly trucked along theback of the panels, adequately supported to prevent sagging (Floor mounted anel shall be mounted on Base frame of ISMC channel size 100x 50 x 5 mm (to be paid Extra)

8

5975

47800

... More
Providing & Fixing of AC operated heavy duty 230/440 Volt power contactor asper PWD specification for electrical Works, 15 marked I5/IEC 60947-4-1:2000having provision of mechanical interlocking, auxiliary contacts, Din rail mountingtype including making connections, testing etc required per preapproved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR 4 pole Power contactors with foflowing AC 1 Rating 40 Amp

1

1700

1700

... More
Providing & Fising of mechanical/digital time switch having following day/weskprogramme and minimum 100 hours reserve and ACS rating of 16-20 amperesincluding making connection, programeming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work, refer Annexure "A" attached with thisisit One day & week reserve (digital type)

1

4100

4100

... More
Providing & Fluing of 240/415 V AC MCB with positive isolation of 101A breaking caрасту (8/2/tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, Smarked 15 8828(1996)/conforming to IEC 60800-1 2002, HC 60947-2, low watt losses, tulp hee mechanisum, energy limiting of class 3as per IEC, minimum phase termination capacity of 15sq.mm.conductor line load reversibility, IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A Gabove rating including making connections, testing etc. as required DEM shall have submit NABL/CP ERDA accrediated lab typetest reports &. All as per pre approved by Engineer in charge. Foradiditional technical parameters of product/work refer Annexure'A' attached with the BSRFour pale MCB (With B/C curve tripping Characteristics150/61 A rating

1

1745

1745

... More
Providing and Laying RCC Foundation for Octagonal/Conical Street Light poles, High mast Poles as perDrawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR A) Excavation of Pit for Foundation Size upto required depth from Ground level) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surfacecomplete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for complete.) Centring and shuttering including strutting, propping etc. and removal of form work for Footing and Pedestalf) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing BR.C.C. work with TMT bars including straightening, cutting, bending, placing inposition and binding all Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs oneach face. Pole Foundation for Octagonal pole from 7 Mtr. To 9

30

7943

238290

... More
P/Lof Double wall corrugated HDPE pipe confirming to 15: 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Tee at required Depth below the ground for layingcable of following Nominal Outer dia. MFR Test report from NABL accrediatedis to be submitted. (Excavation of Earth & Back Filling with compaction is to bepaid Extra) All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work, refer annexure "A" attached withthis B5.50 mm

1200

85

102000

... More
Add Extra for Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width), with procedure as per following points: (e) Make a river sand bed of height 125 mm along the trench, (b) Lay the cablein the middle of the trench, (c) Provide river sand bed of height 125 mm on topof the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Classdesignation 75/Sand stone slabs of 50 mm thickness and 225 mm wide justabove the sand bed vertically across the cable (Approx. 9 no. Bricks per Mtr.), (e)Backfill the excavated soll leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench uptothe ground level and compacting the earth

1200

185

222000

... More
Add Extra in Item no.11.5 if Excavation done in Hard Rock/CC road/TAR Roed and making Good the same

100

24

2400

... More
Supplying and making end termination with heavy aluminium lugs (Pin/ringtype) confirming to 15 8309 1993 & 15 8337-1976 duly crimped with crimpingtool, PVC tape etc of following size. All as per pre approved by Engineer Incharge. For additional technical parameters of products/ work, refer Annexurs "A" attached with this BSR .25.0 Sq.mm

100

7

700

... More
Providing & Fixing of IKOB IP65 protected Top/Bottom mounted LED Post top Luminarie made of singiepiece construction powder coated die cast alluminium housing with UV stabalized Clear/frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminousefficacy 2 100 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integralelectronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS number constant current and internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD 10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 14 Burninghours with 70% of Initial Lumens maintained. Driver current 750mA. Fixture must be in compliancewith BIS Standards and Trade mark Certificate complete in all respect. OEM Must have its own in houseNABL lab setup for all testing facilities for LED flxtures. (LM79/LM80) ertificate/report with liablewarranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer Incharge. For additional technical parameters of products/work, refer Annexure "A" attached with thisBSR Minimum lumen output 4000 im Post top Luminarie

30

6575

197250

... More
Providing & Faing of IKOB IF-66 protected high power LED flood light system with single piece Pressurediecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beamangles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having afficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System levelLuminaire efficacy 125 Im/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff300 V AC and Auto resetting Safety Power Factor 0.95, THD(1) 10%, driver current 750mA driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min4EV internal and 10KV external but inside driver compartment, System life of 50000 Burning hourswith 70% of initial Lumens maintained, CRI70 and CCT $700K £355K, Manufactures Word Mark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbe IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LEDfatures. (LA/79/LMBO) Certificate/report with lable warranty of product/accessories from OEM shallbe submitted. Ali as per pre approved by Engineer in chargs. For additional technical parameters ofproducts/ work, refer Annexure "A" attached with this BSR High Power LED Flood Light Minimum lumen output 12400 Im (warm white)

10

5900

59000

... More
Providing & Plaing of IC10 IP65 protected 600 mm height LED Bollard Luminarle with base plate ofpowder coated die cast alluminium housing with UV stabelized PC diffuser. The System level Luminousefficacy 2: 90 Lumen/W. SMD LED used, System CR70, CCT: 3000/4000/s500 K. The integralelectronic driver must be potted & has a unique BIS R number must be potted & has a unique 815 number constant current and nternal/sxternal surge protection device of 4KVEL-N) and efficiency 85%, PF0.9, THO-20% and input Voltage range of 30-270V AC at 50Hz. Systeme of 30000 hours with 70% of initial Lumens maintained Light output in Cool white or Warm White Colour as perengineers choice, driver current 750mA, Fluturs must be in compliance with Bis Standards and Tisdemark Certificate complete respect OEM Must have its own in house NABL lab setup for all testingfacilities for LED fartures. (LM7S/M80) Certificate/ report with lable warranty of product/accessoriesfrom OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annesure "A" attached with this BSR Minimum lumen output 880 in Bollard

10

11241

112410

... More
Providing and flaing of fuss box alan 250(H) x 200(W) x 150(D) mm fabricated of 1.5mm MS sheet withhinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2. nos poleclamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished withtwo coat of approved enamel paint. The box shall be provided with 2/4 nos copper bus bar 125 20 x 3mm with brass screws suitable supports earth terminal, Inter connection, knock outs for 20/25 mmcabile gland, 1 no. 6 Amp MCB complete in all respect. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work, refer Annexure "A" attached with this BS (As per råde bar 2025)

7

2274

15918

... More
Decorative haritage pole in 4 Meter height. Pole upper section of length 3mtr is of dia 76mm and 1 meter bottom section of dia 114mm with decorative casting with base plate as per drewing, Provision for 22 inside termination box with 4way connector & Ines 6 AMPS MCB for local isolation with cover.Complete in all aspects with foundation bolts. As per ruidp bar 2023)

30

20060

601800

... More
Supply and faing following size of Hot dipped Galvanized (275 GSM) Roorraceweys/Under floor trunking with/without pertion, including commoncover, joint sleeve, cross over junction Box etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters ofproducts/work, refer Annexure "A" attached with this as 300 mm x 38 mm x 2.0 mm with 3 Compartment

6

5222

31332

... More
Providing and laying Non Pressure NP-3 class R.C.C. pipes including collars/spigot jointed with stiff misture of cement mortar in the proportion of1:2 (1 cement: 2 fine sang) etc. as required. (Excavation of Earth & Backingwith compaction is to be Peid Extra). All as per pre approved by Engineer Incharge. For additional technical parameters of products/ work, referAnnexure "A" attached with the 858.200 mm Die

20

560

11200

... More
labour charges for Excavating trenches of required width for pipes dressing oildes, ramming of bottoms, depth to 1.5 Mtr. including taking out theexcavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming watering and disposal of surphs excavated soll as directed within a lead of 30 MrAll kind of Soils.

10

213

2130

... More
Supply & Laying following size earth strip in horizontal or vertical run insurface by means of Earth strip DMC Insulator including riveting/soldering/welding, Jointing shall be done by overlapping and with 2 setof Brass (for Cu strip)/Gi (for Gi Strip) nut bolt & spring washer spaced at50cm making connection etc. as required. All as per pre approved byEngineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this 85820mm x 3mm copper strip

100

781

78100

... More
Supply & Laying following size'B' class, G.I. Pipe confirming to 15: 12399-1 (2004) with accessories like bend, socket etc, for laying earthconductor/strip/cable in ground/surface/recess as required. All as perpre approved by Engineer in charge. (Earth Excavation will be Paid Extra) All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work, refer Annex ure "A" attachedwith this BSR 50 mm dia

50

718

35900

... More
SITC of 3/4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz O AS/C settings, conforming to I5/IEC 60947 P-2:2003 with front face andcentralised adjustable, trip fres mechanisum, true contact positionindicator, line load interchangeability, designed for both horizontal &vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40degree, pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breakingcapacity ics = 100% icu. U imp 8 KV, rated Insulation voltage 690 V provision for UVR, shunt trip, earth fault trip, door interlock, pad lock Brotary handle, including maiting connections etc. as required. OEM shallhave submit NABL/CPRI/ERDA accrediated lab type test certificatebefore execution All as per pre approved by Engineer in charge. Foradditional technical parameters of product/work refer Annexure 'A' attached with this BSR. 4 pole MCCB With Thermal Magnetic release. up to 100 Amp. 10 kA, fized O/L & fixed S/C setting

5

2215

11075

... More
Providing & Fixing of ISO certified company made bus bar chamber housedin sheet metal box as per PWD specification for electrical WorksConfirming to IEC-60439/15-8623 & IEC-60529/15-2147 made out from 1.6mm thick powder coated CRCA sheet, degree of protection IP-31, frontopenable bus bar made out of Copper suitable for 200 amp. Capacity, bus bar fixed on porcelain/DMC insulators at approved spacing includingmaking connections etc. as required. Appropriate type test certificate/OEM test report shall be submitted. All as per pre approved by Engineer Incharge. For additional technical parameters of products/work, referAnnexure "A" attached with this BSR 600 mm long, 4 strip

2

8178

16356

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 withintegral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia forpanel not less then 20 mm, length min. 50mm, front LED cover dia min. mm,contact material phospher bronze for Led, PCB contacts shall be of brass (tinplated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be100 M ohm at 30 500VDC including connection etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters of products/work, refer Annexure "A" attached with this BSR Red/yellow/Green colour

3

170

510

... More
Providing & Fixing of Cam operated rotary (Auto/manual) switches on existingpanel with 2 way and off position using high grade engineering material tointernational standards with cam assembly insulation of glass filled polyamidewith high tracking index. For reliable and stable electrical and mechanicalendurance double butt contacts with silver bi-metal on copper should provided.contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions 31 shall be mechanicallyminimum 50000 operations 300 cycles/hour and electrically 10,000 operationsat 100% rated duty for 100 cycles/hour including making connection etc. asrequired. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR 32 AMP

4

504

2016



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.