If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 79,640Document Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UITBR_438948_1Tender No
online nit24(2024-2025)03Urban Improvement TrustTender Authority
Urban Improvement Trust ViewPurchaser Address
-Website
http://http://urban.rajasthan.gov.in/content/raj/udh/uit-udaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. oIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances ofoxidization, insulation PVC type A/C/D , flame retardant as per IS10810-53, better amperage rating as per IS:3961 part 5, in existingsurface or recessed PVC/ MS conduit/casing capping akingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq.mm
800
43
34400
... More
Supply and installation of spike of M.S. rod 20mm dia 3.0mtr.long for earthing of (tower/pole) drive into earth by mechanicalmeans sturcture connection the spike with cross arm top hamperPCC pole, lattics tower to earth etc. complete as per technicalspecification of DISCOM.
60
1819
109140
... More
Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of singlepiece construction powder coated die cast alluminium housing with UV stabalized Clear / frostedPolycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminousefficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integralelectronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burninghours with 70% of Initial Lumens maintained . Driver current 750mA. Fixture must be in compliancewith BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in houseNABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) ertificate/ report with liablewarranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure "A" attached with thisBSR .Minimum lumen output 4000 lm Post top Luminarie
20
6575
131500
... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ freestanding floor mounted dust and vermin proof compartmentalised cubical panelas specifications and Other parameters required as per point (a) ,(b), (c),(d), (e),(f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments havingconcealed hinged type doors with key type lock with / without detachableextension type structure. Removable 3 mm. thick sheet steel gland plates withappropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing,Activation, derusting, pickling in acid bath, phosphatising & shall be subjecmicrons on both side of panel. The panel having PE foam/ Neoprene rubbergasket of not less than 3mm thickness ,required hardware , concealed hingeddoor with key type locking arrangement for equipment/switchgear earthed with2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidlysupported and made out by flexible copper wires (up to 63 amp ) and by solid busbar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints /interconnections of copper bus bar shall be dully tinned . Clearance betweenmain bus bar and risers / metal parts shall be at least 10 mm additional to widthleeves . Earth and Neutral busbar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire forInterconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not bepermitted. Each terminal block shall be one piece moulded, barrier type, 650 voltgrade, complete with washers, heads, studs with two nuts and identification stripsand shall have adequate continuous current rating. For tap-offs, adjacentterminals with shorting strips shall be used. 10% Spare terminal blocks shall beprovided. Wire identification on marking strip shall correspond to the designationof the wiring diagrams. All wire terminals on the equipment shall also be markedith designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closedin metering chamber, Wiring between terminals of various devices shall be ‘pointto point’ (no wire splitting or tee connectons) with wires neatly trucked along theback of the panels, adequately supported to prevent sagging.(f)Floor mounted anel shall be mounted on Base frame of ISMC channel size 100x 50 x 5 mm ( to be paid Extra )
2
5975
11950
... More
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor asper PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000having provision of mechanical interlocking, auxilary contacts, Din rail mountingtype including making connections, testing etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR .4 pole Power contactors with following AC 1 Rating 40 Amp
2
1700
3400
... More
Providing & Fixing of mechanical / digital time switch having following day / weekprogramme and minimum 100 hours reserve and AC1 rating of 16-20 amperesincluding making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure "A" attached with thisBSR .One day & week reserve (digital type )
2
4100
8200
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3as per IEC, minimum phase termination capacity of 35sq.mm.conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSRFour pole MCB (With B/C curve tripping Characteristics)50/63 A rating
2
1745
3490
... More
Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as perDrawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surfacecomplete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing inposition and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing andPedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommen dations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal includingCuring the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs oneach face.
Pole Foundation for Octagonal pole from 7 Mtr. To 9
60
7943
476580
... More
Providing & Fixing of IK10 IP65 protected 600 mm height LED Bollard Luminarie with base plate made ofpowder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminousefficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integralelectronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS Rnumber constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burninghours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as perengineers choic. driver current 750mA. Fixture must be in compliance with BIS Standards and Trademark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testingfacilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories
from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached with this BSR Minimum lumen output 980 lm Bollard
30
11241
337230
... More
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24,Stiffness Class 750 N, Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Tee at required Depth below the ground for layingcable of following Nominal Outer dia. MFR Test report from NABL accrediatedis to be submitted.(Excavation of Earth & Back filling with compaction is to bePaid Extra)All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer annexure "A" attached withthis BSR .50 mm
1800
85
153000
... More
Add Extra for Laying of one number additional PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade direct in ground in the same trench in one tierhorizontal formation including excavation of trench of size additional 20 cm inwidth, with procedure as per following points :- (a) Make a river sand bed ofheight 125 mm along the trench, (b) Lay another cable in middle of trench insuch manner that spacing between another cable is 20 cm., (c) Provide river sandbed of height 125 mm on top of the cable. (d) Lay the protective Common burntclay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thicknessand 225 mm wide just above the sand bed vertically across the cable ( Approx. 9no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from theGround level, (f)Lay the Cable warning tape and again back-fill the remainingportion of the trench upto the ground level and compacting the earth
1790
127
227330
... More
Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Roadand making Good the same
300
14
4200
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%