If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Urban Improvement Trust - UIT Tender
Electrical and Electronics
Eprocure
Opening Date21 Nov 2024
Closing Soon27 Nov 2024
Tender Amount₹ 8,00,000
Costs
EMD
₹ 16,000Document Cost
₹ 500Tender Fee
₹ 500
Summary
05 - Supply And Fixing Of Pole And Spot Light In Government Senior Secondary School Play Ground At Manpura, In Uit Area Chittorgarh.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UITCG_431927_5Tender No
NIT-14/2024-25 UIT CHITTORGARHTender Authority
Urban Improvement Trust ViewPurchaser Address
-Website
http://http://urban.rajasthan.gov.in/content/raj/udh/uit-udaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing & Fixing of Street light bracket made out from
following size of ' B 'class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavyduty pole clamp, Saddles suitable fastners etc. as required. All as per preapproved by Engineer in charge. For additiona technical parameters ofproducts/ work , refer Annexure ’A" attached with this BSR .
-
-
-
40 MM dia
10
958
9580
Supply and fixing of following LT Supporting accessories
with nut bolt & Clampsmade out as per standard Discom’s specifications with two coats of Red oxideand two coats of Aluminium paint etc. as required.
-
-
-
LT cross arm 1200 mm long with clamp
10
787
7870
P & F IP-65/IP-66 protected high power LED flood ligh
system with extruded aluminium housing toughened glass diffuser with suitable lenses on LED to achieve various beam angles ,240 V,50 Hz High Power LEE Lampssuplied wit hpre wired cable of 1 mtr integrated driver shall be high effciency light output in cool white oi warm white color as per engineers choice, fixtures shal
be Ce and compliance
-
-
-
High Power LED Flood Light 200 W
20
15583
311660
B) Dressing of Pit and Dry stone pitching 200 mm thick
including supply of stones and preparing surface complete.
-
-
-
C) Providing and laying in position cement concrete of M-
10 grade of 75 mm thickness
-
-
-
D) Reinforcement for R.C.C. work with TMT bars
including straightening, cutting, bending, placing in position and binding all complete.
-
-
-
E) Centring and shuttering including strutting , propping
etc. and removal of form work for Footing and Pedestal
-
-
-
F) Providing & Fixing of 2 no. Required Size PLB HDPE
Pipe & Foundation Bolt with template as per OEM Recommendations.
-
-
-
G) Providing and Laying Reinforce cement Concrete of
M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.
-
-
-
H) Providing and Fixing Nosing Angle 40 mm x 40 mm x
6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
-
-
-
Pole Foundation for Octagona( pole from 7 Mtr. To 9 Mtr.
10
7943
79430
Supply & Laying following size' B ' class , G.I. Pipe
confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductorl strip / cable in ground/ surface/ recess as required. All as per pre approved by Ene'neer in charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure "A" attached with this BSR
-
-
-
50 mm dia.
20
718
14360
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B class watering Pipe ,including all accessories like nut bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia
300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineef in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
2
5733
11466
Supply & Laying following size earth wire in horizontal or
vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technica parameters of products/ work , refer Annexure "A' attached with this BSR
-
-
-
10 SWG G.I. ( Hot Dipped ) Wire
30
14
420
Providing & Laying P.V.C. / XLPE insulated & P.V.C.
sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade
electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technica parameters of product / work refer Annexure 'A’ attached with this BSR
-
-
-
6.0 Sq. mm
-
-
-
4 core
350
166
58100
16.0 Sq. mm
-
-
-
4 Gore
10
232
2320
25.0 Sq. mm
-
-
-
3.5 core
10
285
2850
Supplying and drawing FR PVC insulated & unsheathed
flexible copper conductor as per PWD specification foi electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from
99.90 % purity copper, class 5 stranding in acc. tc IS:8130/IEC 60228 for lower watt loss oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduiVcasing capping making connections with Copper Lugs of suitable size, Ferrules, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure ’A' attached with this BSR
-
-
-
3x 1.5 sq.mm
30
63
1890
SITC of IP-42 and general construction confirming to
IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f}, (g), (h) as below:-
-
-
-
(a)Thickness of CRCA sheet shall be 2.0 mm, cable
alley compartments having concealed hinged type doors with key type look with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shal be provided
-
-
-
(b)compIete panel shall undergo a process of
degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
-
-
-
[c) Interconnection between bus bar and switchgears
/cabIe shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shal be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection beMeen Main busbar and Switchgear is to be Paid Extra )
-
-
-
(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shal be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram
-
-
-
(e)AII wiring shall be enclosed in plastic channels and
neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be 'point to point’ (no wire splitting or tee connections) with wires neatly mucked along the back of the panels, adequately
supported to prevent sagging.
-
-
-
(f)FIoor mounted panel shall be mounted on Base frame
of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
-
-
-
(g) Tests: The insulation resistance (vrith 1000 V
Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutra and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
-
-
-
(h) only outer surface area on all sides shall be
measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)AII as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" akached with this BSR
9
5975
53775
Supplying and fixing of Aluminium (IEC 60105 ISO 209-
1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR
-
-
-
Electrolytic grade Aluminium bus bar 6010 grade
15
542
8130
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification foi electrical Works, ISI marked IS/IEC 60947-4-1 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including makincl connections, testing etc. as required. All as per prE approved by Engineer in charge. For additional technica parameters of products/ work , refer Annexure "A'
attached with this BSR
-
-
-
4 pole Power contactors with following AC 1 Rating
-
-
-
100 Amp
2
7849
15698
Providing & Fixing of mechanical / digital time switch
having following day / week programme and minimum
100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as pei pre approved by Engineer in charge. For additiona tect›nicaI parameters of products/ work refei Annexure "A" attached with this BSR
-
-
-
One day & week reserve (Analog type )
2
4690
9380
SITC of 3 /4 pole current limiting Moulded case circuit
breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, |ine load interchangeability, designed for both horizontal & vertica mounting without any adverse e#ect on electrica performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under sic condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure ’A' attached with this BSR
-
-
-
4 pole MCCB With Thermal Magnetic release
-
-
-
up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C
setting,
2
7112
14224
125 Amp , 25 kA, adjustable O/L & adjustable S/C
setting,
2
8391
16782
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 0828(1996)
/ conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. conductor line load reversibility IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including makin9 CCl nnections, testing etc. as
required. OEM shall have submit NABL / CPRI / ERDA
accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technica parameters of product / work refer Annexure 'A’ attached with this BSR
-
-
-
Single pole MCB (With B/C curve tripping Characteristics}
20
187
3740
four pole MCB (With B/C curve tripping Characteristics}
2
1745
3490
P & L of double wall corrugated HDPE pipe confirming to
IS:14930 P-1 & 2 with HDPE copler at 1 mtr depth below the ground for lying cable incudiing making the trench and back filling ,compaction of earth as required of
gemini or IS 14930 marked make outdor dia/inner dia Gf 150/55 mm
200
87
17400
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%