Urban Improvement Trust Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,60,820Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_UITKo_165632_1Bid Award Id
ViewTender No
NIT 30/19-20 (1)Tender Authority
Urban Improvement Trust ViewPurchaser Address
-Website
http://http://urban.rajasthan.gov.in/content/raj/udh/uit-udaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
P&F of IP 65 Protected high power LED flood light system with pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240V, 50Hz- High power LED fixture supplied with pre-wired cable of 1 mtr integrated driver shall be high effciency having effciency 85% and in compliance to IEC standards/ BIS certified. The system level Luminaire efficacy =100 with high power LEDs of CREE/NICHIA/OSRA/PHILIPS make to be used. LEDdriver input voltage AC 110 to 270 AC with auto resetting safety cut off Input frequency 50HZ+- 3%Power factor 0.95 Driver efficiency 85% THD(i)10% Humidity 10% to 90% RH working temp. -20C to 50C . .LED luminaire specifications :Life expectancy equal or more than 50000 burning hours with minimum 70% Lumen maintenance . Manufactures word Mark/Name Engra ved/Embossed on die cast housing to allow tracebility/authenticity till life of fixture. fixtures shall be CE complianed.Group A-I
-
-
-
High power LED Flood Light 160W
18
-
17855.2
High power LED Flood Light 80W
10
-
6908
P&F laying XLPE insulated IS: 7098/II/85 of Group I and approved make H.T. cable for working voltage 11 KV. Earthed direct in ground including excavating of 30 cm x 100 cm size trench 25 cm layer of river sand IInd class brick covering refilling earth compaction of earth making necessary connection testing etc. asMake RPG/Havells/KEI. required of size. Group 1
-
-
-
3 core 185 sqmm.
250
-
1266
Providing and making heat shrinkable type indoor/outdoor/ straight through terminations/ joint kit of Group 1 and approved make suitable for XLPE insulated 11 K.V/33KVcable with required components preparation of cable ends testing etc as required of following sizes. Group 1
-
-
-
3core 120/150/185/225sqmm. Out door kit
6
-
6500
3core 120/150/185/225sqmm. Straight through joint
1
-
15000
P/laying P.V.C /XLPE insulated & P.V.C. sheathed cable of 1.1 k.v. grade with aluminum conductor of IS 1554 P-1/7098 P-I of Group I of approved make in ground as per IS : 1255 including excavation of 30 cm x 75 cm size trench, 25 Cm thick under layer of sand, 11nd class bricks covering, refilling earth compaction of earth making necessary connection testing etc. as required of size Group-I
-
-
-
4corex10sqmm.
3500
-
170
4corex25.0sqmm.
250
-
222
3.5core x 185sqmm.
100
-
917
3.5core x 120sqmm.
1400
-
636
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, aluminium lugs duty crimped with crimping tool, PVC tape etc for following size of armoured PVC insulated & PVC sheathed XLPE aluminium conductor cable of 1100Volt grade as required of size.
-
-
-
4corex25.0sqmm.
30
-
119
3.5core x 185sqmm.
3
-
395
3.5core x 120sqmm.
24
-
310
Supplying and making end terminations with heavy aluminium lugs(Pin / ring type) duly crimped with crimping tool, PVC tape etc of following size
-
-
-
10 Sq. mm
1000
-
8
SITC of Star rated aluminium wound distribution Transformer of following rating 11/0.433KV Delta-star Connected, Vector Group Dyn 11, as per BEE star level -2 & BIS approved with losses as defined as per IS 1180 PART 1 2014. including standard accessories like conservator , silica gel breather, radiator, fins, HT cable box & LT cable boxes, off - LTC(+5% to -10% @ 2.5%) winding temperature gauge, first fill of oil, epoxy based paint, including carrying of pre-commission testing & Charging of Transformer.(Transformer should be CTL tested , w/o any extra cost) group 1
-
-
-
100 KVA
1
-
222346
SITC of 11 KV, 400/630 A, 20kA / 3 sec, Out door Extensible type Ring main unit (RMU) in suitable RCC foundation with 2 no. Load break switch & 1 no. VCB / SF6 circuit breaker with over load, Earth fault, short circuit relay, copper bus bar, earting switch , mechanical on/Off /earth indication , voltage presence indicator ,ring core protection CT 2.5 VA ,10P10 as per transformer rating , shunt trip coil , anti reflex operating handle , right angle boots etc as required
1
-
414560
SITE of Wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, duly treatd for derusting in 7 tank process with dephosphating and with power coating on both side of panel in desired shade. The panel having PU/neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate M.S. base channel hinged door with locking arrangement for equipment/switchgear thickness of sheet shall not be less than 1.6mm upto 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. Channel if required. Side walls and cable alley compartment having bolted type doors with detachable extension type structure.(Only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)
80
-
2752
SITC of quick make and quick break 4 pole current limiting MCCB having following current rating short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C setting and conforming to IS 60947-2/IEC 60947-2 with front face and centralize adjustable, line load interchangeability having positive isolation capability provisions for UVR shunt trip, earth fault trip ,push test to trip including making connection with lugs/ spreaders etc. required. 100 Amp, 25 KA, adjustable O/L & fixed S/C setting. lcs=100% lcu.group1
10
-
6341
up to 125 A, 25 kA adjustable O/L & fixed S/C setting. Ics+100% icu Group 1
5
-
7800
250 Amp, 35 KA, adjustable O/L & fixed S/C setting. Ics+100% icu Group 1
1
-
18989
SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41/IEC:831-1&2 in existing panel or parallet with load terminals, the capacitor shall be fitted with discharge resistors, pressue sensitive disconnect or (PSD) and shall have dissipation factor less then 0.0025 at 50 Hz and total wattage loss less than 0.5 watt per KVAR, including making connections with suitable capacity conductors/cables testing as required. Heavy duty three phase 440V, 50Hz capacitor (Bank). Group 1
70
-
546
P&F of ac operated heavy duty 230/440 Volt power contactor conforming to IS:13947-4-1/EC;947-4-1having provision of mechanical interlocking Din rail mounting type including making connections testing etc. as required. 3 pole power contractor with following AC3 Rating
-
-
-
32amp Group 1
8
-
2150
70amp Group 1
10
-
3196
SITC of microprocessor based three phase sensing
power factor correction relay having following sensing capacity secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, metering facility as required 6 to 8 stage Sensitivity upto 50 milli amp. Group 1
1
-
17205
SF of CT operated direct reading type ampere meter on existing panel making connection by PVC insulated copper conductor with PVC sleeves/channel etc. as required. Digital type below 500A Group1
1
-
1100
SF of (0-500) V range volt meter on existing panel making connection by PVC insulated copper conductor with PVC Sleeves/channel etc. as required. Digital type Group1
1
-
1100
SF of current Transformer with all necessary support in existing panel including connection etc. as required.From150/5 to 5VA, Class 1 accuracy. Group1
8
-
306
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required.Red/yellow/Green colour Group1
3
-
150
Blue colour
1
-
250
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:
-
-
-
New work(Two or more coats applied @3.84 kg/10 sqm)
70
-
56
SF of selector switch of 10 A for voltmeter (4 position) including making connection etc as required.
1
-
228
SF of CT linked selector switch of 10A for ampere meter (4 position) including making connection etc. as required.
1
-
286
P&F paper phenolic resin bonded laminates comfirming to IS :2036-1995 for boxes/frames including making holes for switches fet, with brass screws, washers/zinc plated nut and bolts as required. 9.0mm thick.
17
-
1720
Supply and fixing of aluminium/copper bus bar by means of SMC/DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade aluminium bus bar.
75
-
420
Plate Earthling as per IS: 3043 with G.I Earth plate of size 600 mm x 600 mm x 6.0 mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia G.I. “B” Class watering Pipe including all accessories like nut bolt reducer nipple wire meshed funnel and C.C. finished chamber covered with hinged type with locking arrangement C.I Cover C.I Frame of size 300 mm x 300 mm complete with alternate layers of salt and coke/ charcoal testing of earth resistance as required.
8
-
4250
Supply and installation of spike of M.S. rod 20mm dia 3.0mtr long for earthing of (tower/pole) drive into earth by mechnical means sturture connection the spike with cross arm top hamper PCC Pole, lattice tower to earth etc, complete technical specification of discom.
22
-
650
GI strip 25mmx3mm( Hot Dipped)size.
60
-
58
S&F laying following size earth wire/ in horizontal or Vertical run in ground/ surface/ recess including riveting, soldering, saddles, making connection etc. as required. 8 SWG G.I.( Hot Dippped) Wire.
3300
-
9
P&F of mechanical/ digital time switch having following day/ week programme and min. 100 hous reverse and AC1 rating of 16 to 20 amp including making connections, programming rtc. As reqd . 1 day reverse (mech. Type) Group1
10
-
2297
Providing and Fixing of IP65 Protectd polycarbonate/polysterene fuse box moulded with inside knock outs of following size with hinged cover, trasparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20mmx3mm flat with nut and bolts, complete with. The box shall be provided with Din rail, 4/8way 10.0/16.0 sq.mm heavy duty connector, earth terminal, complete in all respect.160mmx225mmx100mm Group-1
181
-
1500
P&F 240/415V AC MCB with positive isolation of breaking capacity not less than 10KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)1/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as reqd.
-
-
-
Four pole MCB 40A- 63A rating. Group 1
10
-
1378
Four pole MCB 6A- 32A rating. Group 1
40
-
918
Triple pole MCB 6A to 32A rating Group1
8
-
688
Single pole MCB 6A to 32A rating Group1
250
-
151
P&F 240/115 V isolator conforming to IS: 13947-111/ IEC 60947-3 on existing board/ sheet including making connections, testing etc. As required
-
-
-
Four pole isolator 63 A rating Group1
10
-
631
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1KV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
-
-
-
1x2.5sq.mm. Group 1
2600
-
21
1x4.0 sq.mm. Group 1
550
-
30
1x6.0 sq.mm. Group 1
200
-
46
1x10.0 sq.mm. Group 1
150
-
78
1x16.0 sq.mm. Group 1
150
-
131
1x1.5sq.mm. Group 1
2000
-
14
Supplying and making end terminations with heavy aluminium lugs(Pin / ring type) duly crimped with crimping tool, PVC tape etc of following size
-
-
-
2.5 sq.mm. Group 1
100
-
7
4.0 sq.mm. Group 1
100
-
8
6.0 sq.mm. Group 1
120
-
10
10.0 sq.mm. Group 1
120
-
12
16.0 sq.mm. Group 1
200
-
14
1.5 sq.mm. Group 1
100
-
6
P/L of Double wall corrugated HDPE pipe confirming to IS:14930 P-I&2 with HDPE coupler at 1mtr Depth below the ground for laying cable and back filling the trench, conpaction of earth as required of Gemini or IS:14930 marked make outerDia/Inner dia. 50/55 mm
3200
-
100
90/76mm
1600
-
150
S & Laying following size B Class GI pipe confirming to IS:1239 P-1 (1990) with accessories for laying earth conductror/strip/cable in ground/surface/recess as required 32mm dia.
250
-
234
65 mm dia.
165
-
428
80 mm dia.
300
-
554
100mm dia.
100
-
667
Supply & fabrication steel structure with ms channel/angle/joist/ISMB/sheet etc. including welding rivetting cutting nut & bolt painting etc as required.
1000
-
84
S&F following sizes (dia) of ISI marked medium duty PVC conduit along with accessories in surface/ recessed using saddles, clamps, fastener as required including cutting the wall covering conduit and making good the same as required
-
-
-
25mm
100
-
42
Providing & Fixing Test terminal Block in existing mip box for metering as per latest specification of JVVNL.
1
-
700
Providing and fixing current transformer of ratio 200/5A for metering in exixting MIP Box as per latest specification of JVVNL and tested from laboratoray ofJVVNL.
4
-
850
Providing and laying in position cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work upto plinth level. 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size).
23
-
3881
S & making heat shrinkable type outdoor straight through joint for following size of PVC / XLPE insulated aliminium conductor cable of 1.1 KV grade including cost of compound sleeves etc as reqd.
-
-
-
4corex10sqmm.
5
-
556
4corex25.0sqmm.
5
-
806
3.5core x 185sqmm.
2
-
1620
3.5core x 120sqmm.
5
-
1263
P/F Nut & Bolts.
700
-
91
P&F Service connector for one to one wire connection in place of tape
280
-
30
Supply and erection of MS swaged tubular pole as per IS 2713-1980 (Part I& II) and made out from tube of ISI mark for structural purpose with MS base plate in position including excavation of pit filling the same with c.c of M-20 grade (1:1:5:3) from bottom to 50 cm above the ground level with the help of steel frame of 40 cm dia up to bottom section of 114.3 mm OD & 50 cm dia beyond 114.3 mm OD around the pole. duly finished with cement plaster earthing terminal cable entry GI cable sleeve complete as required , the pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation (See Table E-09 for specs.) 7.5Mtr Long. (410 SP-5)
39
-
6408
Add for supply and fixing of MS Overhang of following size over the existing poles.88.9mm ODx3.25mm thickness.
110
-
650
With ready mix Zink chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel
150
-
17
Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade New steel work (Two or more coats)
150
-
49
Painting on new surface with duco paint (IC or equivalent) to give an even shade (minimum 4 coats)with preparation of surface by rubbing , primer coats, duco filler putty including polishing etc. complete On Steel work.
200
-
258