Urban Improvement Trust Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 17,680Document Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UITBR_428230_1Bid Award Id
ViewTender No
online nit 18(2024-2025)01Urban Improvement TrustTender Authority
Urban Improvement Trust ViewPurchaser Address
-Website
http://http://urban.rajasthan.gov.in/content/raj/udh/uit-udaipur/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Work of making four 4 ton tower AC for hall at VPS Park Chowpatty.
BOQ Items
... More
Supply & fixing MS powder coated stand suitable for 2.5/3.0/4.0 Troutdoor type of Split/Ductable/Tower AC. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR .
2
1349
2698
... More
SITC of Interconnecting refrigerant copper pipe for split/Ductable/Casseette AC of DHE Grade C12200- ASTM B68, B75, chemicalcomposition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 .For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation% = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present.Piping between each set of indoor & outdoor units of different sizes asper OEM requirement & specifications including class 'O' Nitrile rubbersleeves, chase cutting, supports, making good the same with sandcement plaster etc. as required. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , referAnnexure "A" attached with this BSR .
30
1987
59610
... More
Supply and fixing duct insulation with 50 mm thick Expanded Polystyrene Thermocol (ESP) sheet of density 24 kg/cu.m after applyingtwo coats of cold setting adhesive (CPRX Compound) and binding sheetwith chicken wire mesh and applying cement mortar plaster (1:4)including primer & painting (suitable for outdoor aplication) matchingwith building colour or as per direction of Engineer incharge as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with thisBSR .
50
985
49250
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/ sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSR. Four pole MCB (With B/C curve tripping Characteristics), 50/63 A rating Each 1745
4
1745
6980
... More
Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provisionof incomer suitable for 3/4 pole MCCB and SP / TP MCB as outgoing,made out from Galvanized steel / CRCA sheet not less then 1.2 mmthick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powderpainted with reversible door (for double door DB only ) completewith insulated 160 (upto 160 A Incomer) / 250 Amp. copper busbar, neutral bars with shrouds, earth bar , color codedinterconnecting wire set of suitable rating and din bar,maskingsheet, making internal DB terminations with copper lugs, ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDAaccrediated lab type test eports & All as per pre approved byEngineer in charge.For additional technical parameters of product /work refer Annexure 'A' attached with this BSR, Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/
125 A Rating with Metal end box4 Way
4
11538
46152
... More
Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances ofoxidization, insulation PVC type A/C/D , flame retardant as per IS10810-53, better amperage rating as per IS:3961 part 5, in existingsurface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR, 4 x 6.0 sq.mm
100
276
27600
... More
Supply and laying PVC Insulated and PVC Round Sheathed Multi Corecopper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.90 % purity copper, stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances ofoxidization, insulation PVC type A/C/D , flame retardant as per IS10810-53, better amperage rating as per IS:3961 part 5, in existingpipe / open trench / Cable tray / on surface including makingconnection etc. as required. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR, 4.0 sq.mm x 6 core Rmtr. 455
150
455
68250
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements