University Of Rajasthan Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 16,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_UORJP_155221_2Bid Award Id
ViewTender No
UE/ACTT/2019-20/2271Tender Authority
University Of Rajasthan ViewPurchaser Address
-Website
http://https://www.uniraj.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, 6 A switch, 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.On board
65
-
90
S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. : 20 mm
250
-
32
S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall, covering conduit and making good the same as required. : 25 mm
250
-
42
Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet , making connection , testing , etc. as required.
40
-
235
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. : 2 x 2.5 sq. mm. + 1x1.5sqmm
500
-
53
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. : 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
500
-
77
P&F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required.
50
-
210
P&F ISI marked 6 amp bakelite batten/angle holder including making connection testing etc. as required.
50
-
20
P&F IS:371 marked 6 amp surface type ceiling rose including making connection testing etc. as required.
130
-
18
P&F 18 swg M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side .
65
-
95
P&F P.V.C. sheet of size 75 mm dia. Including screws, cup washer as required.
65
-
4.4
P & F 1200mm sweep BEE 5 Star rated double ball bearing capacitor start, aluminium body & blade ceiling fan complying to IS 374:1979, 1/p 50 watt at max speed & 230 Volt, air delivery210 CMM, 330 RPM with down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.
40
-
1370
P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper wires with lugs, shorting link, neutral link, earth link and din bar,masking sheet, conforming to IS 13032 & IS 8623 including making internal DB terminations with copper lugs, testing etc. as required. : Double door (Three phase) : 4 Way
6
-
1820
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. : Single Pole MCB 6 A to 32 A rating
80
-
151
P&F metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without MCB) including making connections, testing etc.as required : Single / Double Pole (Three pin) : 32 A
15
-
850
P&F of 36 Watt IP20 LED 2'X2' fixture, Recessed /Surface Type, having efficacy of not less than 100 lumen / watt, made out from CRCA housing and with high purity / transmisvity duffused for uniform light distribution high efficiency driver electronics and in compliance to IEC standards (Integral with light fixture). life ime of more than 50000 burning hours, CCT 6000k (minimum), CRI80 driver maintaining PF0.9
50
-
3950
P&F of capacitor start, metal body, metal blade three speed wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required. : 400 mm sweep(Oscillating type)
28
-
2649
Maintenance free Gel Earthing with Pipe in pipe / Pipe in strip technology filled with anti corrosive conductive compound ( CPRI Tested ) below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineral filling compound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone ) and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes. : With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating : GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip
2
-
6150
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. : 8 SWG copper Wire
100
-
79
P&I of IP66 protected LED Street Light Luminaire on existing bracket, Fixture made of powder coated single piece pressure die cast alluminium with heat dissipation fins on housing with UV stabalized PC/Toughened Glass cover (from 45W onwards) and should be secondary lens on each LED. The system level luminaire efficacy=100with High Power LEDs of CREE/NICHIA/ OSRAM/ PHILIPS/SEOUL make is to be used The LED driver shall be BIS certified and Input Voltage AC 110 to 270 V AC with Input Frequency 50Hz+3% Power factor0.95 Driver Efficiency 85%, THD(1) 10% Humandity 10% to 90% RH working Temp -20C to 50C. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% initial lumens maintained Rendering Index 75% Surge protection shall be min5 KV internal and min 10KV external. Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixture shall be CE complianed : LED Street Light fixture 60 Watt
6
-
4674
P & F strip type fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating / stove enamelled paint) / (extruded non corrosive UV resist EP channel) complete with accessories (Low Loss Copper Choke, starter, starter seat) / Electronic Choke with terminal block duly prewired with copper conductor including making connection, testing etc. as required( without tube). : 1 X 36 Watts with EB
IP - 66 Protected LED Street Light Luminaire
High Power LED Flood Light 30W
80
-
377
S&F of Street light bracket made out from following size of 'B' class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required. : 32 mm Dia.
10
-
410
P/Laying P.V.C./XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I/IS :7098 P-I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. : 16.0 Sq.mm : 4 core
150
-
178
P/Laying P.V.C./XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I/IS :7098 P-I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. : 4.0 Sq.mm : 4 core
100
-
129
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. : Four pole MCB : 40 A 63 A rating
6
-
1378
P&F of Heavy duty capacitor start, Double ball bearing 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. : 300 mm sweep (900/1400 RPM)
4
-
3002
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) : nterconnection between bus bar and switchgears/cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp) and by solid bus bar (125 amp). All joints/interconnections of copper bus bar shall be dully tinned. Clearance between main bus bar and risers/metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves. Earth and Neutral bus bar shll be half of the size of phase bus bar.
4
-
2752
SF of (0-500) V range Volt meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. : Digital type
1
-
1100
SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. : Digital type : Below 500 A
1
-
1100
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. : Electrolytic grade Aluminium bus bar
4
-
420
SF of Current Transformer, with all necessary support in existing panel including connection etc. as required. : up to 150 / 5 Ratio , 5 VA , class 1 accuracy
3
-
306
SF of selector switch of 10 A for voltmeter (4 position) including making connection etc. as required .
1
-
228
SF of CT linked selector switch of 10 A for Ampere meter (4 position ) including making connection etc. as required .
1
-
286
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. : Red/yellow/Green colour
3
-
150
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs & spreaders, etc. as required. : With Thermal Magnetic release : 250 Amp, 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
1
-
16210
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs & spreaders, etc. as required. : With Thermal Magnetic release : up to 100 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
6
-
6341
P/Laying P.V.C./XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I/IS :7098 P-I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. : 50.0 Sq.mm : 3.5 core
150
-
299
P&F Fluorscent tube rod in existing fixtures as required, : Flourscent powder coated (minimum 3 star rating) : 36/40 Watts
80
-
63