Tribal Area Development Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Tribal Area Development Department Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date30 Sep 2022
Closing Date28 Oct 2022
Tender Amount₹ 3,80,42,418 
Notes
Download

Costs

  • EMD

    ₹ 7,60,840
  • Document Cost

    ₹ 1,000
  • Tender Fee

    ₹ 1,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment).

752.88

-

249

... More
Providing and laying in position cement concrete including curing compaction etc. Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size.)

271.54

-

2896

... More
Providing and laying cement concrete including curing compaction etc. complete in retaining walls, return, walls, walls (any thickness) including attached pilasters, columns,piers, abutments, pillars, posts, struts, buttresses string or lacing courses, parapets coping bed blocks anchor blocks plain windows sills, fillets etc. up to floor three level excluding the cost of centering and shuttering.M20 grade Nominal Mix (with graded stone aggregate 20mm nominal size)

2.77

-

4356

... More
Providing and laying in position specified grade of reinforcement cement concrete all RCC structural elements upto plinth level including curing compaction finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement M25 Grade design mix

354.54

-

5498

... More
Providing and laying in position specified grade of reinforcement cement concrete all RCC structural elements upto plinth level including curing compaction finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement M20 Grade nominal mix (with graded stone aggregate 20mm nominal size)

7.16

-

4872

... More
Providing and layingin position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with redering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering shuttering and reinforcement for. Walls (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix

183.79

-

5994

... More
Providing and layingin position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with redering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering shuttering and reinforcement for. Walls (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Design Mix

5.97

-

5372

... More
Providing and layingin position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with redering in cement sand mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering shuttering and reinforcement for. Beams, suspended floors, roofs, griders having slopes up to 15', landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases. M25 grade Design Mix

547.43

-

6012

... More
--- do--- M20 grade Nomial mix (with graded stone aggregate 20MM nominal size)

10.8

-

5244

... More
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.Thermo-mechanically Treated bars (Conforming of relevent IS code)

121534.44

-

72

... More
Random rubble dry stone kharanja under floor.

258.45

-

979

... More
Random Rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in : Cement Mortar 1:6 (1 cement : 6 Sand)

461.49

-

2072

... More
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level.

954.5

-

161

... More
Centering & shuttering with steel plates including strutting , propping, barcing both ways with wooden members and removal of form work up to floor three level for: Walls (any thickness) including attached pilasters, buttresses, plinth and string course.

273.36

-

282

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for: Columns, pillars, posts and struts etc.

1647.3

-

274

... More
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for: Suspended floors, roofs landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam etc.

4358.25

-

223

... More
Brick masonary in foundation and plinth with brichs of class designation 75 in Cement mortar 1:6(1 cement : 6 coarse sand)

12.32

-

3672

... More
Brick masonary in brick work in super structure up to third storey of class designation 75 in Cement mortar 1:6(1 cement : 6 coarse sand)

582.51

-

3864

... More
Half Brick Masonry in superstructure up to third storey including cost of nominal hoopreinforcement ( 2 Nos. 6 mm dia M.S. bar at every forth course ) using bricks of designation 75 in Cement mortar 1:4 ( 1 cement : 4 coarse sand )

800.8

-

468

... More
Providing and fixing T -iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws of rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.

3385

-

96

... More
Provinding and fixing steel glazed doors windows and ventilator shutterd of standard rolled steel section joints mitred and welded eiht steel lugs 13x3mm, 10cm, long embedded in cement concrete block 15x10x10cm of 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 20 mm mominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and othe fitting except necessary hinges of pivots steel handles peg stay etc. as per required:Partly fixed and partly openable (fixed area not to exceed 33%)

193.05

-

1938

... More
------------do-----------------Overall portion treated is fixed (Without glass panes)

17.84

-

1047

... More
Providing and fixing square bars or other flats welded to window, ventilators etc. 10mm Square bars

1063.19

-

73

... More
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.

210.88

-

501

... More
Provinding and fixing in position collapsible steel shutters with vertical M.S. Channels 20x10x2mm and bracket with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outsinde stoppers, handles etc. as per specification including applyig a priming coat of approved steel primer. (To be measured and paid as per outer dimension.) with 75mm opening when closed.

16.81

-

3177

... More
Providing and fixing M.S. sheet single leaf door shutter in angle iron fram 35x35x5mm suitabilly diagonally bracked with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engineer-in-charge but excluding cost of chowkhats: including two coats of anti-corrosive red oxide primer paint. M.S. Sheet 22 S.W.G.

71.21

-

1557

... More
Supply and fixing steel sheet double leaf shutter (almirah Type) with 18 gauge steel frame (Border) and 20 gauge steel shutter including vertical ribs of 40 mm width and 10 mm depth to be spot welded at every leaf or width more than 400 mm of 20 gauge, internal lever locking arrangement and direction of engineer incharge.

268.25

-

2306

... More
Providing and Fixing Stainless steel railling of required grade steel pipe of 16 gauge with one main post of 3 inch dia and 42 inch heigh with ball and base, Bull ester or small vertical post of 1.5 inch dia with 5/8 inch at top with base at every third step or every three fit with base and holds as per requirement. Horizontal Pipe of 5/8 inch 4 Nos. Inside and one main handrail at top of 2 inch, finshed rail height 33 inch complete in all respect and finished (as per direction of Engineer in charge) {Copy of certificate of steel grade used to be provided if demanded} A- for 202 grade steel (internel work)

71.53

-

2700

... More
Supplying & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade :M.P. Teak Wood Grade - 2

0.28

-

90123

... More
Providing and fixing fully panelled double leaf shutters for door as per approved design and drawings with approved steel fittings as per annexure ‘A’ and width of styles, and top rails 100mm and lock rails width 150mm & bottom rail of 200 mm wudth including beading of 25mm x 15mm size on both faces.M.P.teak wood grade-II 35mm thick: D

5.53

-

5478

... More
Providing and fixing fully panelled double leaf shutter for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure -'A' and width of styles bottom & top rails o 75 mm including bending of 25 mm x15mm. size on both faces M.P. Teak Wood Gr-II

3.07

-

3687

... More
Providing and fixing externa grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' 35mm thick commercial veneer both side

134.45

-

2418

... More
Add extra in Flush doors : For external teak wood lipping on flush door. 35mmx6mm

12.04

-

61

... More
Spreading of hot blown bitumen (IS grade 25/85, 25/90 industrial grade) applied at 175 to 180 degree C @ rate of 1.70 kg per Sqm complete.

846.61

-

91

... More
Provinding brick kharanja in cement sand mortar 1:4 in square pattern over roof of ground floor: 75 mm to 100mm thick average

846.61

-

396

... More
Providing and laying 20 to 25 mm size glazed tiles pieces for roof treatment having colour and shade as approved by the Engineer incharge over 25mm thick layer of cement mortar mix 1:4 with application of cement slurry including finishing of joints with ordinary cement and curing etc. complete in all respect washing with acid.

827.53

-

400

... More
Providing batta (Gola) 75mmX75mm in cement concrate (1:2:4) including finishing with cement morter 1:3 as per standerd design.

238.81

-

32

... More
Finishing with 25mm thick cement plaster on roofs in cement sand mortar 1:4 mix including water proofing compound @ 2% of cement used, with neat cement, finishing, curing etc. complete in all respect including making of 300mm x 300mm square.

225.06

-

212

... More
Polished Blue Kota Stone flooring skirting, laid over 20mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete: 20mmhick slab. For area of each slab upto 900 Sq.cm

193.22

-

890

... More
------ Do -------- 25 mm thick slab For area of each slab From 2001Sq.cm to 5000 sq.cm

1508.57

-

1038

... More
Supplying and fixing dressed sand or other approved stone shelves, tands in cement mortar 1:3 with fine dressed edges : 75mm thick.

30

-

942

... More
Supplying and fixing rough dressed stone sills, dasa coping cornices sriwan string course etc in cement mortar 1:4 including pointing with admixture of pigment matching with the stone shades : 75mm thick.

1.86

-

1216

... More
Supplying and fixing in walls machine cut and polished stone shelves tands and sills in CM 1:3 with machine cut edges.Kota stone 25 mm thick

103.76

-

707

... More
Extra over item kota stone shelves for machine cut both side polished stone is used.

43.15

-

47

... More
Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of:Jhansi (Red / Choclate Colour) Above 3601, SqCm

182.18

-

2749

... More
Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of:Jhansi (Red / Choclate Colour) Above 3601, SqCm

52.63

-

1733

... More
Marble stone flooring table rubbed, 16 - 18 mm thick over 20 mm (Av.) thick base of CM 1:4 ( 1 Cement : 4 coarse sand) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding rubbing and polishing complete.Rajnagar Ist quality with light spots. Above 3601 cm 2 Slabs

27.46

-

1374

... More
Marble stone flooring table rubbed, 16 - 18 mm thick over 20 mm (Av.) thick base of CM 1:4 ( 1 Cement : 4 coarse sand) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding rubbing and polishing complete.Rajnagar 2nd quality with light spots and streaks Above 3601 cm2 Slabs

406.34

-

1016

... More
Providing and fixing 1st quality standard white, grey, ivoty, fume red brown, light green, light blue and other light shades glazed tiles ISI marked [IS : 13753] of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls and pillar.) Category-B : Bell, Orient, Thar make etc.

723.55

-

662

... More
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13753 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of meat cenent slurry including nicely finished joints using water proof joint filler powder (Untile or Roffe make) and finishing wiht flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4) Category - B Bell, Orient, Thar make etc.

196.83

-

734.4

... More
P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.Size 600 mm x 600 mm

148.87

-

1190

... More
Providing & laying Chequered plain cement concrete embossed o specially manufatured non-slipping tiles of approved make 20mm thick laid on 20mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete.

58.53

-

331

... More
Plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc. complete fine finish:

6454.53

-

166

... More
Plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc. complete fine finish: 25mm thick,

2880.97

-

209

... More
Finishing with neat cemant (punning)

107.02

-

28

... More
Plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish:25mm thick,

422.88

-

162

... More
6 mm cement plaster to ceiling of mix 1:3 (1 cement : 3 fine sand)

2163.94

-

128

... More
35mm thick Rough chiesel dressed stone flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 ( 1 cement : 6 coarse sand) and jointed with cement sand mortar 1:3 complete in all respects:Kota Stone

157.63

-

425

... More
Applying white cement based putty over cement plaster surface for making even surface

8719.31

-

138

... More
Making grooves as per design in plaster 10mm to 20mm wide

2000

-

8

... More
Making drip course (Tapak ) in Cement sand mortar 1:6 width upto 40mm and 10mm thick as per approved design.

200

-

6

... More
Strictural steel work in single section fixed without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height In flates, tees, angles & Channals

1000

-

66

... More
Providing corrugated G.I. sheet roofing fixrf with G.I.J or L hooks bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete (upto a pitch of 60 degree) & excluding the cost of purlins rafters and truses, for class of sheets.

46.45

-

716

... More
P & F plain fiber glass sheet ( FRP sheet fiber reinforcement product sheet conforming to IS: 12866- 1989 having minimum thickness as below including fixing with nuts, bolts hooks and bitumen washer etc. complet:3.0 mm thick (Wt. 5.0 kg/mtr.sq)

46.45

-

1435

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying Polymen modified cementous slurry mixed with armour cerete of M/s The Structural Water Proofing Company Pvt. Ltd., or Tapecrere of M/s Cico Engineer Service or Hydro Proof of Fosroc consisting of appering : I) first layer of slurry of cement @ 0.488 Kg./sqm mixed with Armourcrete or Tapecrete @ 0.253 Kg/sqm. This layer will be allowed to air cure for 4 hours. II) Second layer of slurry of cement @ .242 Kg./sqm mixed with Armourcrete or Tapecrete @ 0.126 Kg./Sam. This layerwill be allowed to air cure for 4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints corners, junction with polymer mixed slurry.

167.22

-

117

... More
Filling of sunk portion of roof with earthen pots os required height including filling voids with 1:2:4 light concrete, using brick bats with cmplete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification.

49.92

-

788

... More
Extra over item No. 37 for combination flooring of Blue Kota and Marble stones Using above 10% and upto 15% marble stone

1493.34

-

39

... More
S & FCC 1:2:4 (M-15) Precast kerb on dand upto 60 cm length over 20mm thick base of cement mortar 1:6 including jointing, earthwork, painiting and jointing with cement mortar 1:4 of size 15 x 40 cm

121.92

-

305

... More
Providing and fixing of precast concrete interlocking block of M 30 grade manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint on is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes General specification of blocks:1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color : Grey cement natural colour. 4) Variation in dimension : Less than 1.6 mm. 5) Variation in thickness : Less than 3.2 mm. 6) Abrasion : As per BS : 6717:2001 60mm thick interlocking blocks

406.44

-

416

... More
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work incluidng prepraton of base with primer putty lipp complete in all reapect.

2773.95

-

92

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding New work (two or more coats) over and including scrapping and priming coat with cement Drimer.

8618.47

-

43

... More
Painting with enamel paint of approved brand and manufacture to give an even shade :

1180.59

-

78

... More
French sprit polishing Two or more coats on new work including a coat of wood filler.

20.62

-

143

... More
Painting on new surface with duco paint (IC or equivalent) to give an even shade (minimum 4 coats) with preparation of surface by rubbing, primer coats, duco filler putty including polishing etc. complete:

536.5

-

344

... More
Making rebaring of steel reinforcement 8mm to 25mm dia bar including drilling of hall by mechanical means in RCC, Encasing reinforcement & filling apoxi. by gun.

200

-

50

... More
Making linning/ groove 3mm to 5mm in granite step.

200

-

30

... More
Providing & fixing pvc Chicken mesh jali on joint of R.C.C. stricture with brick masonry during plaster work.

100

-

50

... More
Finishing with neat white cement (punning)

712.12

-

28

... More
Cement concrete jali reinforced with 1.6mm dia mild steel wire complete as per approved design excluding plastering of jambs , sills and soffits

49.05

-

618

... More
Extra for providing edge moulding to 18mm thick marble stone counters, vantities etc. over item No. 7.1 & 7.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer - in- Charge. Granite Work

430.07

-

170

... More
Marble/Kota stone Work

180

-

110

... More
Random Rubble stone masonary for superstructure above plinth level one storey height above 30 cm. thick walls in : Cement mortar 1:6 ( 1 Cement : 6 Sand )

51.02

-

2313

... More
120CM high fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30 cm in ground embedded in cement concrete, 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonal of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete.

64.01

-

343.88

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding New Work ( Three or more coats)

422.88

-

53

... More
Providing and fixing steel gate grating and grills made of angles, tees, square bars or flats black pipe with holdfast and fittings complete as per deign and drawing including cutting welding and fabrication with priming coat of red oxide.

800

-

83

... More
Extra of square rectangular hollow tubular section are used.

800

-

9

... More
P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (I.S: 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:Size 580x440 mm

21

-

1738

... More
P & F European type white glazed vitreous china 1st quality W.C. pan (I.S: 2556 Mark) with P or S trap including cutting and making good the wall and floor.

3

-

1208

... More
P&F Water closet Seat Covers with brass hinges Complete: Solid Pvc (ISI Marked) grade -1 Black for EWC

3

-

462

... More
P & F W.V.C. Half-Round Channel of approved make in C.M. 1.3 joints finished in white cement of

10

-

550

... More
P & F Low level Flushing Cistern of 10 litres capacith (IS : 2556 mark), of approve make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS : 1703 mark) complete including cutting and making good the wall: PVC with PVC bend as per IS 7231

1

-

1157

... More
P & F WVC wash basin (1st quality, I.S.: 2556 mark) of approved make with C.P. pillar cock (I.S.: 8934 mark) & 32mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall. Size 580 X450 mm

23

-

1936

... More
P &F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor. 1.0 mm thick Salem stainless steek AISI- 304 kitchen sink of approved make with large waste coupling. Overall Sizes 24 x 18 x 8 Bowl sizes 20 x 16 x 8

6

-

3450

... More
P & F Beveled edge Mirror of special glass of approved make complete with 6 mm thick asbestos cement sheet ground fixed to wooden screw & washers.Size 600 x 450mmx4mm thick.

25

-

275

... More
P & F Towel Rail or Ring of approved quality/ make: C.P. brass towel rail with brackets 450 x 20 mm

6

-

278

... More
P & F Gratting of approved quality / make Stanless steel sheet size 125 mm dia

63

-

62

... More
P & F Soap dish or Tray of approved quality/make C.P brass

5

-

57

... More
P & F shower arm 15 mm dia of approved quality /make C.P. brass heavy & superior quality 150 mm Projection

26

-

115

... More
P & F bath shower of approved quality /make C.P. brass fixed

4

-

91

... More
P & F extension pipe for bib cocks of approved quality/make C.P. brass of heavy & superior quality 50 x 15 mm

30

-

58

... More
P & F Acrylic Toilet accessories set consisting of Towel rail, shelf, towel ring, soap dish, paste and brush holder and twin peg of approved quality/make

1

-

810

... More
P & F jet spray for water closet with C.P. Copper tube flange of approved make

3

-

248

... More
P & F GI pipes ( Internal works ) with GI fittings(IS:1239 ) marked and MS clamps, including cutting and making good the wall and floors. Exposed on wall 15mm dia NB B Class

110

-

176

... More
25mm dia NB B Class

110

-

293

... More
P & F GI pipes ( Internal works ) with GI fittings(IS:1239 ) marked and MS clamps, including cutting and making good the wall and floors. Concealed pipe in wall including anti corrosive bitumen paint 15mm dia NB B Class

50

-

190

... More
P & F GI pipes ( External works ) with GI fittings(IS:1239 ) marked and MS clamps, including trenching and refilling earth etc. 15mm dia NB B Class

85

-

179

... More
25mm dia NB B Class

110

-

281

... More
32mm dia NB B Class

100

-

315

... More
50mm dia NB B Class

120

-

517

... More
Making connection of GI distribution branch with GI main including all fitting.Upto 25mm dia

12

-

235

... More
Beyond 25mm & Upto 100mm dia

7

-

350

... More
P & F Bib cock (IS : 8931 mark) superior quality of approved make C.P. brass bib cock 15mm nominal bore.

25

-

571

... More
P & F Bib cock (IS : 8931 mark) superior quality of approved make C.P. brass long body bib cock 15mm nominal bore weight not less than 690grm.

35

-

722

... More
P & F Stop Cock (IS :8931 Mark), superior quality & of approved make: Concealed Stop Cock 15mm.

24

-

634

... More
P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete Brass wt.400 gm,15mm.

13

-

256

... More
P&F Inlet connection (Angle Valves) Superior quality, of approved make, for Wash basin, gyser etc, C.P, Inlet connection 15 mm brass (IS : 8931 marked)

24

-

495

... More
P & F 15 mm. Dia Connection Pipe of approved quality/make 450mm.

20

-

98

... More
P & F Flush Cock / Flush Valve (IS : 9758 Mark) for WC of approved quality make : concealed 32mm nominal bore.

24

-

1025

... More
P & F Full way valve (IS : 778 mark or wheel valve of approved make.Gun-metal 15 mm dia nominal bore

17

-

285

... More
Gun-metal 25 mm dia nominal bore

17

-

540

... More
Gun-metal 32 mm dia nominal bore

6

-

659

... More
Gun-metal 50 mm dia nominal bore

5

-

1488

... More
P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality 50 mm nominal bore.Horizontal

1

-

978

... More
P&F PVC Storage Tank (IS : 12701 marked indicating the BIS license No.) of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. 500 liters

1

-

4047

... More
750 liters

4

-

5433

... More
1000 liters

8

-

7658

... More
Add extra for Hoisting charges for each floor and Tripple layered water tanks 750 liters

4

-

150

... More
1000 liters

8

-

240

... More
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :15mm dia nominal bore

18

-

38

... More
25mm dia nominal bore

18

-

78

... More
32mm dia nominal bore

10

-

112

... More
50mm dia nominal bore

10

-

211

... More
Providing & laying C.C. 1:5:10 (stone aggregate 40mm nominal size) all around S.W. pipe including 15Cm. Thick bed concrete(width W = diameter of pipe in cm+30cm) copncrete width to be reduced from width W at center of pipe to O at top of pipe,(excluding cost of pipe) around 160mm rigid PVC pipe

100

-

315

... More
P& F& Joining R.C.C. class NP-2 Non Pressure pipes (IS:458 mark) of approved make with collars, jointed with C.M. 1:2 or having spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete: 300mm dia internal

50

-

330

... More
P & F rigid PVC pipe (IS:4985 mark) class II(4kg./Cm.) approved quality / make including joining the pipe with solvent cement rubber ring and lubricant.75 mm dia

95

-

119

... More
110 mm dia

440

-

196

... More
160 mm dia

90

-

236

... More
P&F rigid PVC pipe fitting (IS : 4985 mark) of approved quality/makw including joining the pipe with solvent cement ruber ring and lubricant : Coupler 110 mm dia

32

-

85

60

-

85

... More
Plain Tee 110 mm dia

16

-

136

11

-

89

... More
Door tee 110 mm dia

20

-

150

10

-

128

... More
Bend 87.5

33

-

110

11

-

79

... More
Plain Floor Trap 110 mm dia

62

-

177

... More
Pipe Clip 110 mm dia

105

-

40

55

-

35

... More
Vent covel 110 mm dia

5

-

52

... More
Gully trap 110 mm dia

5

-

382

... More
Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.size 450 x 450mm depth upto 0.5 M Cement cover with frame

4

-

1846

... More
Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring, earthwork complete as per approved drawing including disposa+C1201l of earth within a lead of 50 mtr Size 240 Cm. dia outside & 240 Cm. depth.

3

-

10166

... More
Construction of Main hole, in all types of soil, inner size .90 * .60 M, with 450mm thick masonry in CM 1:6, 10 CM. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring Ferro cement cover with frame of 450mm dia earth work etc complete including disposal of surplus earth with in 50 mtr lead as per design Depth up to 0.5 M

7

-

3542

... More
Construction of septic tank in all type sof soil with 40cm thick masonry in CM 1:6 15cm thick CC bed of 1:5:10 M-15 grade CC flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3, Ralthal, Kharanja, 50mm thick stone partiton walls, 20mm thick plaster in CM 1:6 finished with neat floating cement, 4Nos C.I. foot rests of approved design, two No. 450mm dia 25Kg each C.I. cover with frame, earth work etc. complete as per approed drawing incl. disposal of surplus earth wtihin a lead of 50mtr. Size 200 x 100 x 130 cms (for 10 users)

1

-

18576

... More
P & F stop cock (IS :8931 mark), superior quality & of approved make Brass 400 gm. 15mm nominal bore.

2

-

305

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Short point (up to 3 mtr.)

77

-

359

... More
Medium point (up to 6 mtr.)

228

-

578

... More
Long point (up to 10 mtr..)

254

-

772

... More
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR On board

252

-

357

... More
Medium point (up to 6 mtr.)

5

-

726

... More
Long point (up to 10 mtr..)

72

-

920

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

61

-

580

... More
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Blanking plate

200

-

22

... More
Modular MCB 6 A to 32 A DP (IS:8832 marked)

4

-

461

... More
Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 5 step fan regulator 2 Module 360 dgree rotating

111

-

398

... More
Blanking plate

3

-

15

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1 x 1.5 sq.mm

1550

-

22

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

1528.1

-

81

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm

893

-

122

... More
2 x 6.0 sq. mm. + 1 x 4 sq. mm

300

-

185

... More
4 x 10.0 sq.mm

300

-

531

... More
1x 4.0 Sq.mm.

360

-

48

... More
2 x 6.0 sq. mm. + 1 x 2.5 sq. mm

5

-

100

... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp.  insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set  of suitable rating and din bar,masking sheet,  making internal DB  terminations with copper lugs, Ferrules,  detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Glazed door (Three phase) IK-09 and IP-43 with Metal end box 6 Way

8

-

6126

... More
Glazed door (single phase) IK-09 and IP-43 with Metal end box 12 Way (12+2)

8

-

2990

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating

228

-

187

... More
Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating

5

-

566

... More
40 A rating

8

-

900

... More
Four pole MCB (With B/C curve tripping Characteristics) 50/63 A rating

12

-

1745

... More
Triple pole MCB (With D curve tripping Characteristics) 6 A to 32 A rating

6

-

947

... More
p& f Recessed/Surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with suitable rating insulated copper bus bar, shorting link, neutral link, earth link and din bar, masking sheet, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs, testing etc. as required. Gr.-1 Double door (Single phase) 8 way

1

-

952

... More
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 20 mm

1220

-

40

1020

-

56

390

-

115

... More
Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Up to 457 mm size

18

-

348

... More
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

111

-

128

... More
Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 300 mm sweep(900/1400 RPM)

16

-

3175

... More
P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Up to 380 mm size

16

-

287

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1170mm(+/-10%) LED batten with min. lumen output 2200 lm

185

-

492

... More
Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency 85% . System Lumen efficacy of ≥ 110 lm / watt, THD 10 % , Pf.≥0.95, CRI 80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Surface Mounting (with extruded alumn. Housing ) Minimum lumen output 1950 lm

139

-

1620

... More
Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD 10 % , p.f.≥0.95,CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Surface Moutning Minimum lumen output 3600 lm

9

-

2862

... More
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value =4.0 to 4.5 )

111

-

1890

... More
Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

110

-

212

... More
Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be = 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM

4

-

4699

... More
Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. 300 mm sweep

2

-

1822

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 95.0 Sq. mm 3.5 core

100

-

714

... More
Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 3.5 x 95.0 sq.mm

2

-

601

... More
Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.(e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 17.2 mm thick and 3 Mtr. Long

4

-

7010

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 8 SWG copper Wire

75

-

148

... More
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy =125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety , Power Factor 0.95 driver Efficiency 85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .LED Street Light fixture with Minimum lumen output 2450 lm

3

-

2554

... More
LED Street Light fixture with Minimum lumen output 7500 lm

5

-

4942

... More
Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 32 mm Dia.

9

-

742

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4 pole MCCB With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

8

-

7112

... More
200 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

1

-

15348

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade

25

-

1301

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

15

-

3443

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Three phase Ammeter with Inbuilt Selector Switch

2

-

1689

... More
Three phase Voltmeter with Inbuilt Selector Switch

2

-

1689

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Ring type tape wound CT C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA

9

-

788

... More
Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Voltage Between Phases with OFF ( 4 Position )

2

-

351

... More
Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

384

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Red/yellow/Green colour

12

-

170

... More
Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Open execution type  200Amp

1

-

11691

... More
Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

328

... More
Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC type Fire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificate from OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 6 kg

8

-

4576

... More
Providing & Fixing of Electrical insulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)

2

-

2043

... More
SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . For single phase Submersible / Monoblock pump 2.0 HP to 3.0HP DOL starter

1

-

5406

... More
Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) , including making inlet, outlet Flexible alloy connection, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 15 Ltr.

1

-

10304

... More
P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 40mm x 40mm x 5mm

15

-

367

... More
Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs

2

-

75878

... More
Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .6 to 8 stage

1

-

14995

... More
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 pole Power contactors with following AC 3 Rating Up to 12 Amp

3

-

1033

... More
13 to 25 Amp

3

-

1346

... More
Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs (temp class - 25 D) in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D) including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)

20

-

374

... More
SITC of RO water system with Filteration stage = Particalate filter - Membrane life enhancer filter - sediment filter - Pre carbon filter - RO membrane filer - Post carbon filter . Input power - 230 V AC , 50Hz , Percentage of Rejection TDS-90% or better having following fiturees (a) Double purification by RO with ESS or latest techonology with TDS indicator . (b)Spin welded RO membrane Housing to prevent tempering (c)Push fit components for leak proof perfomance (d) Fully automatic operation with auto start and auto off (e) SS/ ABS construction for corrosion free lifespan (f)nEqually suitable for water from all bore wells , overhead storage tanks,water tankers and even municipal tapos (g) RO membrane Flushing - Auto Flush @ Every Start ., Every Stop and every One hours of working for one minute . complete in all respect , with following capicity Make : Kent / Eureka Frobes / Ion Exchange / Electrolux / Voltas

3

-

55600

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% ,p.f.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. 4' LED Tube shape fixture 18/20 W (Polycarbonate Base)

2

-

228

... More
Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathedUn-armoured /Armoured aluminium cable of1.1KV grade as perPWDspecificationforelectricalWorksinexistingRCC/Hume/Stoneware/PVCpipe/openduct/cabletrenchwithfillingofexcavatedearthintrench,onexistingcabletraysoronsurfaceetc.includingmakingnecessaryconnection,testingetc.asrequiredofsizeandasperpoints(a),(b),(c),mentioned below:-(a) Material:-H4-Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming toIS8130, IS3975-1999 for armouring of cables in armoured cable items ,IS5831forsheath,IS10810 (Part 0 to 64 ) for testing procedures .(c) OEMMust haveI SO9001&14001 certifications for quality assuarance &its own in house NABL labsetup for all testing facilities for cables.Appropriatety petest certificate/OEM test report shall be submitted.Allabove as per pre approved byEngineer incharge.For additional technicalparameters of products /work,refer Annexure" A"attached with this BSR . Armored Cable. 6.0 Sq. mm X 2 Core

71

-

69

... More
SITCofchemicalGelearthingsystemofDualPipeTechnologymadeofwith"B"ClassGIPipeasperIS1239(part- ):2004of Medium duty of following sizes as perpointsmentioned(a),(b),[c), (d), (e) below :-(a)filled with anticorrosive conductive compounds with the permanent sealings at both theends ,CPRI/ ERD Atested with RMS capacity of minimum 35-40KA for with standing 1 second (b)To ensure the moisture content and electrical conductivity ,25kg for 2000mm &50Kgs for 3000 mm of resistance lowering earth enhancement material shall be used asabackfillcompound.ThecompoundshallbetestedformNABLacredeatedlabforlowresistivity(lessthan0.12Ohm- meter) & high conductivity in nature with car bona samaj or content as per referance of IS3043-1987 ,IEEE80-2013 (clause14.5d),IEEE837 & IER 1956 with latest amendemnts ©Heavy duty weather proof poly-propyleneearthpit chamber with lockable Jam free lidsuitable for safe working load 5000Kg or more of size Top Dia.225 to 260 mm,Bottom Dia 300to 350mm. and Height 250 to 300 mm GI pipe 2000 mm long, 50/25 mm, Terminal 40 mmx6mmGI Strip

1

-

4063

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 8 SWG copper Wire

5

-

148

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor 0.95 driver Efficiency 85% ,THD(I) 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced LED Street Light fixture 45 Watt

1

-

4283

... More
Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD 10 % ,p.f.≥0.95, CRI 80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade markcertificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. LED Downlight 18/20W

10

-

763

... More
P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as reqd. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .Up to 380 mm size Up to 380 mm size

1

-

204

... More
Construction of Tube-well upto 100 meter depth and above in all type of rocks by DTH system and over burden to accommodate casing pipe of following sizes in all types of soil and over burdens including lowering of casing pipes but excluding cost of casing pipes as per IS: 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have throughout bore as per nominal dia of casing pipe (Site to be verified by approved geologist): 150 mm dia Nominal bore.

100

-

590

... More
Supply of ERW M.S. block casing pipe ISI marked (IS: 4270/1992) of grade Fe 410 of following sizes at site of work. For depth more than 25 Mtrs, site to be certified by hydrogeologist that soil is collapsible) 150 mm dia Nominal bore.

25

-

1165

... More
S & F tube well cover of M.S. Sheet (6 mm thick) with nuts and bolts complete for casing size: 150 mm dia Nominal bore.

1

-

236

... More
S & F M.S. clamp, set of 50x6 mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.

1

-

250

... More
Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 12mm (suitable up to 50 mm OD pipe)

125

-

43

... More
SITC of Radial / mixed flow ISI marked water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline. The radial flow pumpset should operate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for Bore well. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. 3.0 HP, 1-Ø, (40- 170)Mtr, (60-20) LPM copper wound

1

-

42469

... More
Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Vertical installation 40 mm OD 6 kg / cm2

115

-

94

... More
P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4.0 Sq.mm 3 core flat / Round

120

-

214

... More
SITC of Contactor OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps etc. suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . For single phase Submersible / Monoblock pump 2.0 HP to 3.0HP DOL starter

1

-

5406



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.