State Agricultural Marketing Board Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

State Agricultural Marketing Board Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 Dec 2023
Closing Date12 Jan 2024
Tender Amount₹ 33,71,000 
Notes
Download

Costs

  • EMD

    ₹ 67,420
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
C. Fan Section comprising of belt driven, DIDW Backward curved AMCA certified centrifugal fan with maximum air outlet velocity of 10m/s suitable for required cfm at 50 mm static pressure (Total static of the unit shall be verified by the OEM before the design & supply of the units). Fan & Motor should be mounted over Aluminium channel of suitable thickness and should be isolated from the unit's bottom panel by means of Spring isolators.

-

-

-

... More
D. TEFC High efficiecny IE-3 class motors as required with pulley, belt , Guard

-

-

-

... More
E. The unit shall be fabricated with frame work hollow extruded aluminium profile with 0.80 mm preplasticised GSS on outside and 0.80mm 275gsm plain GSS on inside complete with 25 mm thick CFC free PUF insulation of minimum 40 kg/cum density sandwiched in between inner and outer skins. Unit should have MS powder coated legs to give height to unit's base channel from the floor surface. SS-304 ( 18 g ) Sump, UPVC Internal piping, make up, drain & quick fill and drain connection, Butterfly/Gate valves for pumps, make up, drain & quick fill and drain connections of sump, 2 no. Vertical Pumps of suitable capacity to be placed inside the unit's housing (external pumps are not acceptable) ,Y strainers and necessary fittings, Concrete Blocks / M S stand, anti vibration pads etc.as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

-

-

-

... More
Upto 7500 cfm

2000

56000

28

... More
SITC of Wall mounting cubical type Starter panel made out of 1.6 mm thick sheet steel  powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of following cfm range Air Washer's Blower motor, pump comprising of over load protection relay, short circuit & single phasing protection, ON / OFF  push buttons,  ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Upto 7500 cfm

2

29686

14843

... More
Supply , Installation, Testing and Comissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

12824

6412

... More
P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

4046

2023

... More
SITC of VFD OEM fabricated VFD cum Bypass starter panel Confirming to IEC60721-3-3, IEC60068-2-60 & IEC60068-2 for variable torque applications, 3C3 avg., 200% torque producing capability at min freq of 0.5 Hz, integrated with 3 to 5% of input reactor or built in DC reactor, Max output frequency 400Hz, built in braking chopper till 30KW, built in RS485 Modbus RTU, Min 7DI, 2DO, 2AI, 1AO, onboard control supply of 24V -150 mA for external operations, RJ45 port, Monitoring parameters – V, I, Torque, Freq, RPM, Watt Hour, DC bus voltage, Analog input V or mA, I/O Status, PID loop monitoring, Torque speed, speed limit, Cooling fan, Protection functions – Ground fault, Over current, Overload, UV/OV, Under/over torque, I/P & O/P phase loss, DBR O/L, inverter over hit alarm, DC bus charge LED indication, heatsink thermistor open detection, stall prevention, fault history of min 4 last faults. Bypass starter shall be provided as per type 2 coordination etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3.7 KW

2

158634

79317

... More
Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
0.60 mm

500

485000

970

... More
0.80mm

650

750750

1155

... More
1.00mm

100

138600

1386

... More
Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed aerofoil shaped horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

-

-

-

... More
Supply air grill with key operated volume control damper

70

737100

10530

... More
Supplying, installing and balancing of extruded Aluminium powder coated fresh air inlet louvers with bird screen & volume control damper fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

10

83710

8371

... More
Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6" pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

10

51280

5128

... More
Supply and fixing of acoustic lining of ducts with chemically cross link Oxide accetate foam open cell structure Acoustic Insulation with density 30 Kg / Sqm, UV protected and Class O Fire propperty Water Vapour absorption 0.002 gm / Sqcm, including cost of adhesive etc. complete in all respect. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
10 mm thick

60

45300

755

... More
Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All as per pre approved by Engineer in charge.

-

-

-

... More
9mm thick for indoor Application

80

57440

718

... More
13mm thick for Outdoor Application with 26 SWG Aluminium Cladding

15

17220

1148

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-

-

-

-

... More
(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided

-

-

-

... More
(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.

-

-

-

... More
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )

-

-

-

... More
(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.

-

-

-

... More
(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.

-

-

-

... More
(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )

-

-

-

... More
(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.

-

-

-

... More
(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2.5

14938

5975

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

1.5

813

542

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
4 pole MCCB With Thermal Magnetic release

-

-

-

... More
up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting

3

6645

2215

... More
125 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

1

8391

8391

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
10.0 Sq. mm

-

-

-

... More
4 core

80

15360

192

... More
16.0 Sq. mm

-

-

-

... More
4 core

50

11600

232

... More
Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8337 -1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
10.0 Sq.mm

16

160

10

... More
16.0 Sq.mm

8

104

13

... More
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

11466

5733

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
20mm x 3mm Alum. Strip

9

990

110

... More
Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia

-

-

-

... More
200 mm dia per running inch length

414

138276

334

... More
SITC of IR IP Based 5 MP Dome camera : 1/2.8" Progressive CMOS, ICR, IR, 2560(H)xl 920(V):25fps(P) , 2.8/3.6 mm lens (As per site requirement) H264,H265/MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: minimum 30 mtr, Provision for Support on-board storage up to 256 GB (SD card not included), intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : 20 °C - 50 °C or better. Model should be : CE, BIS/UL,FCC,ROHS compliance. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAII as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

12

96000

8000

... More
SITC of IR IP based 5 MP Bullet Camera 5 MP , Video Resolution: 2592(H)xl 944(V) Pixels , I to @25 fps; Image Sensor: 1/2.8-inch CMOS; Built in Infra-Red: 40 to 50 mtr; High Dynamic Range- 120 dB WDR; Lense- 2.8/3.6 mm, ;H264,H265/MJPEG , provision for Support on-board storage up to 256 GB (SD card not included) , intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous 27.2 access), Open standard to support ONVIF (PROFILE S, PROFILE G), Metal Housing, Vandal-proof housing IP 67, DC 12V & PoE, Complete with Junction box for cable management Oerating Conditions : -30°C to + 70 °C or better. Onvi1 Profile S,G,Confinnant;Model should be : CE, BIS/UL,FCC,ROHS complianceThe CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in Rajasthan aII as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

18

147600

8200

... More
Supply, Installation, Testing & Commissioning of 32 ch NVR Pre-licenced, NVR supports upto 40 TB HDD Support, 32 ch IP inputs; ; Support ANR technology; 320mbps incoming bandwidth, supports up to 12MP full channel recording; support H.265 compression; 16ch syncronised playback @1080p; support 3rd party cameras ONVIF type; 4K output; minimum 04 SATA HDD Slots; each slot should suppport upto I OTB HDD; Dual gigabit self adaptive Ethernet interface; serial interface; USB interface; (all cameras and Storage-NVR should be of same make for the smooth functioning of the system).complete with mounting accessories & junction box (to be provided by OEM) for cable management. Model should be : Certificates oJ Compliance: UL, CE/FCC, BIS. The CCTV OEM should have CMMI Level 5 or above or equivalent setup certification. The CCTV OEM should have its office and service/ support center in RajasthanAII as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

1

38500

38500

... More
Supply, Installation, Testing & Commissioning of of 3.5" 6 TB SATA ,USB 3.0 Surveillance Hard Disk .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

2

28320

14160

... More
Supply, Installation, testing and commissioning of BIS compliance Professional series Diagonal Screen size 43" LED with Resolution 3,840 x 2,160 (4K UHD) along with Static (Panel) Contrast Ratio (1300:1) or better with viewing angle of 178/178 degree with response time of 8ms along with HDMI In 2.0 - 2 nos., USB 2.0 2 nos., RS 232- 1 nos., RJ 45- !Nos. with Built in Speaker(l0W + !OW), with high speed processor and android or other reputated operationg system along with 4 GB RAM along with all audio and video decoder, Stand-by/ sleep/ off mode power 0.5 watt, . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

1

38600

38600

... More
Supply, Installation, Testing & Commissioning of 1 KVA 1 Phase Input,with IGBT Based Rectifier True Online Double Conversion Robust design Wide input voltage range: 160-300VAC @ 100% load (linearly derating to 50% load @ I00VAC input). Generator Compatible with Wide Input voltage window Double Conversion Efficiency 91 % & ECO mode efficiency up to 98% I 00% load @ 0-40C operating temp. Active Input Power Factor Correction 0.99 0/P power factor 0.9 Inbuilt OVCD (Over Voltage Cut-off device) Fully conform coated PCBA adaptable to harsh environment Offer terminal blocker on 2K/3K rating to connect to big capacity equipment Digital Charger Technology provide 02-10 A charging current Easy understanding LCD for convenient installation setup with Minimum 60 minute battery back up (26AH x 3 Nos of SMF batteries branded and recommended by UPS OEM, battery stand and interlink FR PVC copper cable of appropriate size and lugs), with required cabling for incoming & outgoing connection. UPS should be NABL certified with CE, ROHS & BIS compliance. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.

1

33250

33250

... More
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

700

34300

49

... More
Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Cat 6, Un-sheilded Information Outlet

64

25472

398

... More
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single Aperture

32

2592

81

... More
Supply, Installation, Testing and Comissioning of Rack mounted 19" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Modular Patch Panel Loaded with Cat -6 I/O

2

17530

8765

... More
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord

-

-

-

... More
0.50 Mtr

32

4736

148

... More
1 Mtr

32

7136

223

... More
Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
9 U Rack with Width 600 mm & Depth 400 mm + 100 mm

1

12142

12142

... More
Supply, Installation, Testing and Commissioning of L2 managed Switch;24X10/100/1000 BASE-T port and with min 4x 1000/10000 BASE-X SFP (With 2 SFP module for fiber Giga Connectivity); Total power budget: minimum 350W, Switching Capacity 56 GBPS or better; MAC Table 8K or better; Rack mounting; Flow Control; QoS; 802.1Q Standard VLAN, Network Management; Wide working temperature: -05-55°C; Lightning Protection Common mode 4KV; Certificate of compliance: CE/FCC, including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work refer Annexure "A" attached with P.W.D. Electrical B.S.R. 2022.

1

29776

29776

... More
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
20 mm

100

4000

40

... More
25 mm

200

11200

56

... More
Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1-2-3 Module

32

3136

98



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.