SMS Medical College Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

SMS Medical College - SMSMC Tender

Goods
Chemical Products
Eprocure
Opening Date5 Aug 2024
Closing Date7 Oct 2024
Tender Amount₹ 4,00,00,000 
Notes
Download

Costs

  • EMD

    ₹ 8,00,000
  • Document Cost

    ₹ 5,000
  • Tender Fee

    ₹ 2,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Creatinine – with standard, linearity 20 mg/dl & above (Enzymatic/Jaffe modified)

204

-

-

... More
Phosphorus – Liquid stable ready to use with standard, linearity 15 mg/ml & above (U.V. end point using ammonium molybdate)

60

-

-

... More
Uric Acid – with standard liquid stable standard, linearity 20 mg/dl & above (Uricase peroxidase with no ascorbate oxidize)

72

-

-

... More
Triglyceride – with standard, linearity 1000 mg/dl & above (GPO-PAD)

96

-

-

... More
Calcium – Liquid stable with standard linearity 20 mg/dl& above (Arsenzoe III)

108

-

-

... More
Phospholipid – with standard linearity 500 mg/dl & above {CHO (Choline oxidize) – POD(presence of peroxide enzymatic – colorimetric)}

1080

-

-

... More
SGOT – Kinetic, linearity 500 U/l& above (IFCC without pyrdoxal phosphate method two reagent kit) (Liquid stable reagent)

300

-

-

... More
SGPT – Kinetic, linearity 500 U/l & above (IFCC without pyrdoxal phosphate method two reagent kit) (Liquid stable reagent)

300

-

-

... More
LDH – Liquid stable, linearity 1500 u/l & above (P →L method) IFCC

72

-

-

... More
CPK-NAC – Liquid stable, linearity 1500 U/l & above (Creatinine kinase kinetic IFCC method))

180

-

-

... More
CPK MB –liquid stable, linearity 2000 U/l & above, kinetic (NADH Kinetic) with control & Calibrator

156

-

-

... More
Amylase – Liquid stable, linearity 2000 U/l and above (Kinetic using CN PG3)

84

-

-

... More
Lipase – Kinetic, linearity 700 u/l, with standard and controls (Enzymatic colorimetric )

242

-

-

... More
Alkaline Phosphatase – Kinetic, linearity 1000 u/l (IFCC or AACC optimized method using AMP buffer)

1200

-

-

... More
Total Protein – Linearity 15 gm/dl & above(Biuret)

108

-

-

... More
Albumin – Linearity 7 gm/dl & above (Bromocresol green)

108

-

-

... More
Iron + TIBC – Liquid stable, linearity up to 600 mg/dl suitable for fully auto Analyzer Ferrozine method)

100

-

-

... More
Acid Phosphates – Kinetic, linearity 80 u/l & above (NaphthyI Phosphate Kinetic with pentaanedise activation)

50

-

-

... More
Bilirubin – Biochromatic kit suitable for Auto analyzer, linearity 20 mg/dl & above preferably single reagent for total and direct bilirubin (Diazo with sulphanilic acid)

1600

-

-

... More
LDL Cholesterol – (Direct) suitable for Auto Analyzer, linearity 1000 mg/dl & above with calibrator & control. Calibrator should be traceable to internationally accepted norms.

50

-

-

... More
Gamma GT – Liquid stable, linearity 250 u/l & above (IFCC CY – glutamyl 3 – Carboxy 4 Nitroanilide)

60

-

-

... More
Quality Control (Normal) Human sera based 1. Assigned values should be available for major automated analyzers, making this control a highly efficient solution for laboratories that focus on routine tests. 2. Quality control should be aqueous, clear matrix 3. Quality control should have 3 year shelf life at 2-8°C 4. Quality control can be stored for up to 12 month at 20-25°C 5. Should have open vial stability at least 25 to 30 days. 6. Quality control should be USFDA approved 7. Quality control provider should offer peer group reports as and when required. 8. Company should have offer of QC Data management solutions & connectivity to support controls. 9. Company should offer inter laboratory program 10. Company should offer individual laboratory comparison report with Bias and Histogram Report 11. Company should offer affiliated laboratory comparison report. 12. Company should offer monthly evaluation report 13. Traceable certificate to be enclosed

72

-

-

... More
Quality Control (Abnormal) Human sere based 1. Assigned values should be available for major automated analyzers, making this control a highly efficient solution for laboratories that focus on routine tests. 2. Quality control should be aqueous, clear matrix 3. Quality control should have 3 year shelf life at 2-8°C 4. Quality control can be stored for up to 12 month at 20-25°C 5. Should have open vial stability at least 25 to 30 days. 6. Quality control should be USFDA approved 7. Quality control provider should offer peer group reports as and when required. 8. Company should have offer of QC Data management solutions & connectivity to support controls. 9. Company should offer inter laboratory program 10. Company should offer individual laboratory comparison report with Bias and Histogram Report 11. Company should offer affiliated laboratory comparison report. 12. Company should offer monthly evaluation report 13. Traceable certificate to be enclosed

72

-

-

... More
HbA1c – Kit suitable for Auto Analyzer with calibrator 1.Should be NGSP and IFCC approved. 2. Quality control should be third party. 3. Turbidometric inhibition immunoassay or Enzymatic

60

-

-

... More
Multi-analyte Calibrator for calibrating biochemical parameters should be traceable to internationally accepted standards/ norms. 1. Should be human sera based. 2. Should have long stability 3. Should have maximum number of biochemical parameters.

48

-

-

... More
Total Lipids – with standard linearity up to 1500 mg/dl & above, ready to use for Auto Analyzer

400

-

-

... More
CSF Protein – Linearity up to 250 mg/dl with standard and calibrator. Minimum of 2 vials per kit calibrator should be provided with each kit. (2 x 3 ml)

60

-

-

... More
CSF Protein quality control-5ml 1. Human based material 2. True third party control providing unbiased performance assessment 3. Assayed target values available 4. Shelf life of 2 years from the date of manufacture 5. Open vial stability of 30 days for all analytes when stored at 2°C to 8°C

70

-

-

... More
HDL Cholesterol – (Direct) clearance two reagent method suitable for auto analyzer linearity up to 180 mg/dl with calibrator and control. Calibrator should be traceable to internationally accepted norms. Control and calibrator volume approx. 3 ml per kit.

960

-

-

... More
Blood Gas Quality control material should be designed to meet the expanded test menus of today’s blood gas analyzers. :- 1. Quality control should include Ph,Blood Gas, Electrolytes and Metabolites. 2. Quality control should be aqueous,clear matrix 3. Quality control can be stored for up to 12 months at 20-25°C 4. Quality control should be USFDA approved 5. Quality control provider should offer peer group reports as and when required. 6. Analytes: 1) Calcium(Ionized) 2) Chloride 3) Glucose 4) Lactate(Lactic Acid) 5) pCO² 6) Ph 7) pO² 8) Potassium 9) Sodium 10) TotalCO²

12

-

-

... More
Quality Control Tri – Level – For routine monitoring of both accuracy and precision with assayed instrument specific target values. Including fertility, steroid-thyroid hormones, tumor marker, vitamins etc. Minimum Parameters Free T3, Free T4, TSH Anti TPO (Anti oxidaze ), FSH, LH, Prolactin, Beta HCG,Testosterone, Cortisol, Growth Hormone, (HGH) , PTH, Insulin, Ferrtin, Vitamin B12, Folate, CEA , Alpha Feto Protein (AFP), PSA , Total IgE, Vitamin D , *Anti CCP, CA -125 1. Lyophilized human origin serum 2.Reconstituted stability of at 2°C to 8°C, at least 25 days at 20°C 3. Assigned values should be available for major automated analyzers, making this control a highly efficient solution for laboratories that focus on routine tests. 4. Quality control should be USFDA approved Quality control provider should offer peer group reports as and when required.

60

-

-

... More
Serum Magnesium – 1) Method – Calmagide Method 2) Linearity 5 mg/dl& above with control & Calibrator 3) Liquid stable suitable for fully automated analyzer

36

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.