SMS Medical College Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 12,00,000Document Cost
₹ 1,000Tender Fee
₹ 2,500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_SMSMC_374043_1Bid Award Id
ViewTender No
2888_04.10.2023Tender Authority
SMS Medical College ViewPurchaser Address
-Website
http://eproc.rajasthan.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
300
-
-
... More
Femoral heads should be COCR Metal Head with all sizes 28mm/32mm/36mm
300
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
300
-
-
... More
Total Hip replacement (THR) – All Sizes
Un cemented: -(Ceramic on Poly)
All should be of Same Make
Implant Should be USFDA approved only
-
-
-
... More
The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length options, two offset options minimum and made up of Ti6Al4V material.
400
-
-
... More
The acetabular shell should HA coated/ porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws.
400
-
-
... More
Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
400
-
-
... More
Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm.
400
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
400
-
-
... More
Total Hip replacement (THR) – All Sizes
Cemented: - With metal on poly. Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
Cemented femoral stem should Highly polished, Double tapered with collarless design.
200
-
-
... More
The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 28 /32 / 36 mm with OD 46 – 60 mm with two packets of bone cement.
200
-
-
... More
Femoral heads should be COCR Metal Head with all sizes 28mm/32mm/36mm
200
-
-
... More
Total Hip replacement (THR) – All Sizes
Hybrid ( Metal on poly ) Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
The acetabular shell should HA coated/ porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws.
100
-
-
... More
Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
100
-
-
... More
Cemented femoral stem should Highly polished, Double tapered with collarless design with required Bone Cement.
100
-
-
... More
Femoral heads should be COCR Metal with all sizes 28mm/32mm/36mm
100
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
100
-
-
... More
Total Hip replacement (THR) – All Sizes -Hybrid: (Ceramic on Poly) Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
The acetabular shell should HA coated/ porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws.
100
-
-
... More
Cemented femoral stem should Highly polished, Double tapered with collarless design with required Bone Cement.
100
-
-
... More
Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible toaccommodate 28mm, 32mm, and 36mm heads.
100
-
-
... More
Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm.
100
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
100
-
-
... More
Total Hip replacement (THR) dual mobility uncemented– All Sizes
( Metal on poly) Note: - All should be of Same Make
Implant Should be USFDA approved only
-
-
-
... More
The acetabular shell should HA coated/ porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws.
The system should compose of a Liner and Poly Insert. The system should incorporate the following dual points of articulation- • 22.2mm or 28mm femoral Metal head.
• Large polyethylene insert that mimics a femoral head
100
-
-
... More
Dual Mobility Liner- • Dual Mobility Liner should be made of CoCr.
• The system should have inner change locking mechanism and positive rotation tabs
• The Liner should come with Removal Tool Slot.
• The Liner should be available in all sizes- 36 to58
100
-
-
... More
Poly Insert- The insert should be made up of Highly Cross linked polyethylene which should be wear resistant
100
-
-
... More
The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck lengthoptions, two offset options minimum and made up of Ti6Al4V material.
100
-
-
... More
Femoral heads should be COCR Metal with all sizes 22.2/ 28mm
100
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
100
-
-
... More
Total Hip replacement (THR) dual mobility uncemented– All Sizes
( ceramic on poly) Note: - All should be of Same Make
Implant Should be USFDA approved only
-
-
-
... More
The acetabular shell should HA coated/ porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws.
a. The system should compose of a Liner and Poly Insert. b. The system should incorporate the following dual points of articulation- c. 22.2mm or 28mm femoral ceramic head.
d. Large polyethylene insert that mimics a femoral head
100
-
-
... More
Dual Mobility Liner- a. Dual Mobility Liner should be made of CoCr.
b. The system should have inner change locking mechanism and positive rotation tabs
c. The Liner should come with Removal Tool Slot.
d. The Liner should be available in all sizes- 36 to58
100
-
-
... More
Poly Insert- a. The insert should be made up of Highly Cross linked polyethylene which should be wear resistant
100
-
-
... More
The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck lengthoptions, two offset options minimum and made up of Ti6Al4V material.
100
-
-
... More
Femoral heads should be ceramic with all sizes 22.2/ 28mm
100
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
100
-
-
... More
Total Hip replacement (THR) dual mobility cemented – All Sizes ( Metal on poly) Note: - All should be of Same Make except cement
Implant Should be USFDA approved only • Cemented Dual Mobilty should have sizes 45 to 63 • Head sizes 22 and 28 with 4 option • Can be converted with Uncemented DM with same instruments on table
100
-
-
... More
Total Hip replacement (THR) dual mobility cemented – All Sizes ( ceramic on poly) Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
• Cemented Dual Mobilty should have sizes 45 to 63 • Head sizes 22 and 28 with 4 option • Can be converted with Uncemented DM with same instruments on table
100
-
-
... More
Complex/ Revision hip replacement with all type & size of wedges & cages etc.THR.
Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
Revision uncemented stem should be long and length should be between 180 - 380 mm, Modular or distal fixing stem.
100
-
-
... More
Revision uncemented acetabular shell have multi hole with min. 8 holes and HA/ highly porous Coated.
100
-
-
... More
Revision uncemented acetabular shell should provide dual mobility cup which composed of CoCr liner and highly crossed linked polyethylene which support 22- and 28-mm femoral metal head.(optional)
100
-
-
... More
Acetabulum augments
100
-
-
... More
Acetabulum mesh.
100
-
-
... More
Acetabulum cages various sizes
100
-
-
... More
Uncemented acetabular shell especially designed for protrusion which is peripherally locking.
100
-
-
... More
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
100
-
-
... More
Revision cemented stem should long and the length would more than 200 mm, with bone cements.
100
-
-
... More
The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cementspacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 28 /32 / 36mm with OD 46 – 60 mm.
100
-
-
... More
The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length
options, two offset options minimum and made up of Ti6Al4V material.
100
-
-
... More
Femoral heads should be COCR Metal Head with all sizes 22mm/ 28mm/ 32mm/ 36mm.
100
-
-
... More
Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
100
-
-
... More
Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm.
Note- Should provide quotation for individual components.
100
-
-
... More
Total Knee replacement Cemented(TKR) – All Sizes Note: - All should be of Same Make except cement
Should provide both PS and CR knee
Implant Should be USFDA approved only
-
-
-
... More
Primary Cemented TKR- Femoral components various sizes
500
-
-
... More
Tibial Baseplate various sizes
500
-
-
... More
highly crossed linked polyethylene various sizes
500
-
-
... More
patellar component various sizes
500
-
-
... More
Bone Cement
Note: - All should be of Same Make except cement
500
-
-
... More
Unicondylar Knee replacement
Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
Fix Bearing various sizes
50
-
-
... More
Mobile Bearing various sizes
50
-
-
... More
Complex primary Knee replacement all size and stems and wedges
cemented TKR should have following components
Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
femoral components compatible with stem extension
200
-
-
... More
Tibial Baseplate compatible to stem extension
200
-
-
... More
Primary highly crossed linked polyethylene
200
-
-
... More
Bone Cement antibiotic/ normal
200
-
-
... More
fluted Stem
200
-
-
... More
patellar component
200
-
-
... More
Revision Knee replacement all size and stems and wedges
Semi constraint TKR should have following components
Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
Femoral component compatible with stem extension.
100
-
-
... More
Tibial Baseplate compatible to stem extension.
100
-
-
... More
Semi constrained polyethylene.
100
-
-
... More
Distal Augments.
100
-
-
... More
Posterior Augments
100
-
-
... More
Offset
100
-
-
... More
Tibial wedges various options
100
-
-
... More
Patellar component
100
-
-
... More
Fluted Stem
100
-
-
... More
Bone Cement
100
-
-
... More
Revision knee replacement all size and stems and wedges
Hinge TKR should have following components
Note: - All should be of Same Make except cement
Implant Should be USFDA approved only
-
-
-
... More
Femoral component compatible with stem extension.
100
-
-
... More
Tibial Baseplate compatible to stem extension.
100
-
-
... More
constrained polyethylene.
100
-
-
... More
Distal Augments.
100
-
-
... More
Posterior Augments
100
-
-
... More
Offset
100
-
-
... More
Tibial wedges various options
100
-
-
... More
Patellar component
100
-
-
... More
Fluted Stem
100
-
-
... More
Bone Cement
100
-
-
... More
Reverse shoulder replacement implants – all sizes
All should be of Same Make
Implant Should be USFDA approved only .
(Technical Specification as per Annexure -5)
50
-
-
... More
Total shoulder replacement (TSR) implants- all sizes
Implant Should be USFDA approved only
All should be of Same Make
(Technical Specification as per Annexure -5)
50
-
-
... More
HEMI Shoulder replacement implants – all sizes including fracture stem
All should be of Same Make
Implant Should be USFDA approved only (Technical Specification as per Annexure -5)
50
-
-
... More
Total Elbow replacement (TER) – implants – all sizes
Implant Should be USFDA approved only
All should be of Same Make except cement (Technical Specification as per Annexure -5)
25
-
-
Evaluation Notes How It Works ?