Ravindra Nath Tagore Medical College Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 8,00,000Document Cost
₹ 1,000Tender Fee
₹ 2,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RNTMC_385230_3Bid Award Id
ViewTender No
37/28-2-2024Tender Authority
Ravindra Nath Tagore Medical College ViewPurchaser Address
-Website
http://eproc.rajasthan.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in or tined lead • Life long warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism
• AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• USFDA/PMDA approved
-
-
-
... More
Dual Chamber Pacemaker (DDD) with peel away sheath 6 Fr. • Screw in or tined lead • Life long warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism
• AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• CE- approved
-
-
-
... More
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in or tined lead • Life long warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism
• AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• USFDA/PMDA -approved
-
-
-
... More
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. • Screw in or tined lead • Life long warranty • Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism
• AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• CE -approved
-
-
-
... More
Single Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead should be compatible with 8 Fr. Peel away Sheath • Small size below 35cc
• Warranty : Minimum 8 Years
• Heart Failure Congestion Monitoring Trends with Alerts
• 40J delivered energy with programmable Tilt and pulse width programming
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave overspending
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert
• Facility of specially coated Device for avoiding lead abrasion
• Proactive Measurement of ST Segment changes with Alerts
• USFDA/PMDA approved
-
-
-
... More
Single Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead should be compatible with 8 Fr. Peel away Sheath • Small size below 35cc
• Warranty : Minimum 8 Years
• Heart Failure Congestion Monitoring Trends with Alerts
• 40J delivered energy with programmable Tilt and pulse width programming
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave overspending
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert
• Facility of specially coated Device for avoiding lead abrasion
• Proactive Measurement of ST Segment changes with Alerts
• CE-approved
-
-
-
... More
Dual Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr. peel away sheath
• Small size below 35cc
• Warranty : Minimum 8 Years
• Heart Failure Congestion Monitoring Trends with Alerts
• Facility for overdriving Atrium for prevention of Atrial Arrythmias
• 40J delivered energy with programmable Tilt and pulse width programming.
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave over sensing
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert
• Proactive Measurement of ST Segment changes with Alerts
• Facility of specially coated Device for avoiding lead abrasion (optional)
• USFDA/PMDA approved
-
-
-
... More
Dual Chamber ICD set • Should be supplied with 7.0 to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead profile: should be maximum up to 5 .8 Fr. And lead should be compatible with 6 Fr. peel away sheath
• Small size below 35cc
• Warranty : Minimum 8 Years
• Heart Failure Congestion Monitoring Trends with Alerts
• Facility for overdriving Atrium for prevention of Atrial Arrythmias
• 40J delivered energy with programmable Tilt and pulse width programming.
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave over sensing
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with patient Alert
• Proactive Measurement of ST Segment changes with Alerts
• Facility of specially coated Device for avoiding lead abrasion (optional)
• CE- approved
-
-
-
... More
Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Heart Failure Congestion Monitoring Trends with Alerts
• Facility for overdriving Atrium for prevention of Atrial Arrythmias
• Electrocardiogram based AV Optimization for suggesting optimized AV Delays
• warranty : Minimum 5 years on Device
• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead
• Programmable AT/AF Alerts with AF Burden trending
• Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF
• Facility of RF Telemetry
• Should be supplied with 6 compatible leads and Introducers for RA & RV
• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional
• USFDA /PMDA approved
-
-
-
... More
Cardiac Resynchronization Pacemaker with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Heart Failure Congestion Monitoring Trends with Alerts
• Facility for overdriving Atrium for prevention of Atrial Arrythmias
• Electrocardiogram based AV Optimization for suggesting optimized AV Delays
• warranty : Minimum 5 years on Device
• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead
• Programmable AT/AF Alerts with AF Burden trending
• Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF
• Facility of RF Telemetry
• Should be supplied with 6 compatible leads and Introducers for RA & RV
• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional
• CE - approved
-
-
-
... More
Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• 40J delivered energy
• Pulse width and Tilt : Programmable as per DFT
• Heart Failure Congestion Monitoring Trends with Alerts
• Small size below 35cc
• Warranty : Minimum 5 years
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave over sensing (optional)
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional
• Facility of specially coated Device for avoiding lead abrasion (optional)
• USFDA /PMDA approved
-
-
-
... More
Cardiac Resynchronization defibrillator with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• 40J delivered energy
• Pulse width and Tilt : Programmable as per DFT
• Heart Failure Congestion Monitoring Trends with Alerts
• Small size below 35cc
• Warranty : Minimum 5 years
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave over sensing (optional)
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional
• Facility of specially coated Device for avoiding lead abrasion (optional)
• CE - approved
-
-
-
... More
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in or tined lead • Standard warranty of minimum 10 yrs.
• Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism
• AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• USFDA/PMDA-approved
-
-
-
... More
Dual Chamber Pacemaker (DDDR) with peel away sheath 6 Fr. –with conduction system pacing (CSP) • Screw in or tined lead • Standard warranty of minimum 10 yrs.
• Auto capture mode • Minimize ventricular pacing mode • Beat to Beat capture mechanism
• AF suppression • Optimization of AV delay • Pacemaker lead profile should be maximum up to 5 .8 Fr.
• Lead should be compatible with 6 Fr. peel away sheath
• 3.0 T MRI compatible (full body)
• CE-approved
-
-
-
... More
CRT-P with conduction system pacing (CSP) – with all accessories CRT-P with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Heart Failure Congestion Monitoring Trends with Alerts
• Facility for overdriving Atrium for prevention of Atrial Arrythmias
• Electrocardiogram based AV Optimization for suggesting optimized AV Delays
• warranty : Minimum 5 years on Device
• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead
• Programmable AT/AF Alerts with AF Burden trending
• Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF
• Facility of RF Telemetry
• Should be supplied with 6 compatible leads and Introducers for RA & RV
• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional
• USFDA /PMDA approved
-
-
-
... More
CRT-P with conduction system pacing (CSP) – with all accessories CRT-P with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-P • LV lead-upto 5 Fr. • RV lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• Heart Failure Congestion Monitoring Trends with Alerts
• Facility for overdriving Atrium for prevention of Atrial Arrythmias
• Electrocardiogram based AV Optimization for suggesting optimized AV Delays
• warranty : Minimum 5 years on Device
• Special Algorithms to Predict Lead failure and Protection inappropriate shocks during failed lead
• Programmable AT/AF Alerts with AF Burden trending
• Facility of specially coated Device for avoiding lead abrasion (optional) • Special Trigger Mode Biventricular Pacing in Presence of AT/AF
• Facility of RF Telemetry
• Should be supplied with 6 compatible leads and Introducers for RA & RV
• LV lead delivery systems should be compatible with 7 Fr. EP catheters optional
• CE- approved
-
-
-
... More
CRT-D with conduction system pacing (CSP) – with all accessories
CRT-D with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• 40J delivered energy
• Pulse width and Tilt : Programmable as per DFT
• Heart Failure Congestion Monitoring Trends with Alerts
• Small size below 35cc
• Warranty : Minimum 5 years
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave over sensing (optional)
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional
• Facility of specially coated Device for avoiding lead abrasion (optional)
• USFDA/PMDA- approved
-
-
-
... More
CRT-D with conduction system pacing (CSP) – with all accessories
CRT-D with with all accessories - RA, RV and Quadripolar LV leads and catheters CRT-D • LV lead-upto 5 Fr. • RV defibrillator lead : Should be supplied up to 7.6 Fr. Defibrillator lead compatible with 8 Fr. Peel away Sheath • Atrial lead up to 5.8 Fr. and compatible with 6 Fr. Sheath
• 40J delivered energy
• Pulse width and Tilt : Programmable as per DFT
• Heart Failure Congestion Monitoring Trends with Alerts
• Small size below 35cc
• Warranty : Minimum 5 years
• Facility of Changing the shocking vector based on Over Current sensing
• Special Sensing filter protection for T Wave over sensing (optional)
• Special Algorithms to Predict Lead failure and Protection from inappropriate shocks during failed lead with vibratory patient Alert optional
• Facility of specially coated Device for avoiding lead abrasion (optional)
• CE- approved
-
-
-
... More
Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • USFDA /PMDA - approved
-
-
-
... More
Pacemaker lead with peel away sheath only (without pulse generator) for the existing company providing complete pacemaker at RNT medical college • CE - approved
-
-
-
... More
LONG SHEATHS/INTRODUCERS - PREFACED VALVED LONG SHEATHS FOR RFA WITH MULLINS CURVE, MULTIPURPOSE CURVE, OTHER CURVES, 7F TO 9F, ATLEAST 80- CM LONG, 0.038 WIRE COMPATIBLE
-
-
-
... More
LONG SHEATHS/INTRODUCERS - BRITE TIP INTERVENTION SHEATHS WITH TIP VISUALIZATION, KINK RESISTANT, COLD SHAPABLE WITH SILICON COATING
-
-
-
... More
LONG SHEATHS/INTRODUCERS - INTRODUCER SHEATHS FOR ELECTROPHYSIOLOGY, WITH VARIOUS SWARTZ CURVES SL 0-4, SR 0-4, 8F, 8.5F , 9F
-
-
-
... More
LONG SHEATHS/INTRODUCERS - LONG SHEATHS (PEEL AWAY, SLITTABLE, WITH BREAKING VALVE) FOR SPECIAL APPLICATIONS LIKE CORONARY SINUS INTUBATION, LATERAL VEIN, SPECIAL CURVES LIKE RENAL, HOOK SHAPE etc
-
-
-
... More
LONG SHEATHS/INTRODUCERS - PEEL AWAY INTRODUCER SHEATHS WITH BREAK AWAY HWMOSTATIC VALVES FOR PACING LEADS, 5F-12F, 10 cm – 30 cm, OPTIONAL INFUSION SIDE PORT, RADIO-OPAQUE DISTAL TIP AND MULTIPLE CURVES
-
-
-
... More
PACING LEAD STABLIZERS-
-
-
-
... More
SURFACE PATCH FOR 3 D MAPPING – (ADULT & PEDIATRIC)
-
-
-
... More
LONG SHEATHS/INTRODUCERS - PREFACED VALVED LONG SHEATHS FOR RFA WITH MULLINS CURVE, MULTIPURPOSE CURVE, OTHER CURVES, 7F TO 9F, ATLEAST 80- CM LONG, 0.038 WIRE COMPATIBLE
-
-
-
... More
LONG SHEATHS/INTRODUCERS - BRITE TIP INTERVENTION SHEATHS WITH TIP VISUALIZATION, KINK RESISTANT, COLD SHAPABLE WITH SILICON COATING
-
-
-
... More
LONG SHEATHS/INTRODUCERS - INTRODUCER SHEATHS FOR ELECTROPHYSIOLOGY, WITH VARIOUS SWARTZ CURVES SL 0-4, SR 0-4, 8F, 8.5F , 9F
-
-
-
... More
BALLOON CATHETER FOR NON-CONTACT 3 D MAPPING
-
-
-
... More
DIAGNOSTIC EP CATHETERS - The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable.
All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur
Configurations would be Pole, French. Curve of catheter, Electrode configuration, Fixed / deflectable
-
-
-
... More
WOVEN EP DIAGNOSTIC CATHETERS –
(woven material with braided conducting wire, ensuring prolonged stability)
The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable.
All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur
Quadripolar, 5-7, Josephson, 2-5-2-5, Fixed
-
-
-
... More
CABLES FOR EP & RFA –
The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable.
All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur
Quadripolar Cable, Compatible with Quardripolar Catheter
-
-
-
... More
CABLES FOR EP & RFA –
The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable.
All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur
Decapolar Cable, Compatible with Decapolar Catheter
-
-
-
... More
CABLES FOR EP & RFA – The vendor should quote for each catheter separately if prices differ based upon French size, curve, electrode catheter design (electrode size, electrode distance, electrode material) etc. It will be easier if the common catheters use like 6F, Josephson curve, electrode configuration 2-5-2-5, stainless steel electrodes/Platinum, Palladium electrodes are specified first. All cable should be quoted separately. Cost mentioned for each item will be compared based on the catheter and cable.
All items should be compatible with EP Tracer system installed at RNT Medical college, Udaipur
Hexapolar Cable, Compatible with Hexapolar Catheter
-
-
-
... More
Bi-Directional Steerable Catheters
Handle- Thumb Wheel or Push Pull
Automatic Curve Lock Mechanism
Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size(Fr) Electrode Spacing(mm) Curve, Small, Large 4.0
-
-
-
... More
Dual Curve RF Ablation Catheter
Bi-Directional Steerable Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size(Fr) 7.8 Fr
Electrode Spacing(mm) 2-5-2 mm
Curve,Medium,,Large,,Extra Large
-
-
-
... More
ABLATION CATHETERS (ITEMS 1-10) - (ALL SIZES 4F TO 8.5F, ALL CURVES A-K, 270, all electrode sizes and spacing, e.g.) (ALL ITEMSS DIFFERING IN MAKE/PRICES NEED TO BE MENTIONED SEPERATELY. Quote separately if different in terms of material, braiding, electrode material Platinum, Palladium or stainless steel etc) QUOTE WITH APPROPRIATE CONNECTOR TO EXISTING EPT 1000 AND STOCKERT ABLATORS. EPT 1000 is not compatible with Thermocouple and appropriate catheters/ connectors should be quoted. Thermistor catheters would therefore by preferred. In addition give prices of ALL CONNECTOR CABLES / ACCESSORIES SEPERATELY.
All items should be compatible with existing EP Tracer machine in RNT Medical College, Udaipur Type Ablation Catheter Regular Tip Size 4 mm
Diameter 6-8F Curves/Reach All (Equivalent to A-F, J, K, 270) Comments
-
-
-
... More
BALLOON CATHETER FOR NON-CONTACT 3 D MAPPING
-
-
-
... More
ABLATION CATHETERS (ITEMS 1-10) - (ALL SIZES 4F TO 8.5F, ALL CURVES A-K, 270, all electrode sizes and spacing, e.g.) (ALL ITEMSS DIFFERING IN MAKE/PRICES NEED TO BE MENTIONED SEPERATELY. Quote separately if different in terms of material, braiding, electrode material Platinum, Palladium or stainless steel etc) QUOTE WITH APPROPRIATE CONNECTOR TO EXISTING EPT 1000 AND STOCKERT ABLATORS. EPT 1000 is not compatible with Thermocouple and appropriate catheters/ connectors should be quoted. Thermistor catheters would therefore by preferred. In addition give prices of ALL CONNECTOR CABLES / ACCESSORIES SEPERATELY.
All items should be compatible with existing EP Tracer machine in RNT Medical College, Udaipur Type Ablation Catheter Irrigated Tip(Open)
Tip Size Any Diameter 7-9F Curves/Reach
All Curves/Reach Comments
-
-
-
... More
CATHETERS, CABLES, ACCESSORIES FOR ENDOCARDIAL SOLUTIONS (ESI) ACCESSORIES
-
-
-
... More
REUSABLE DEFIBRILLATION/TRANSCUTANEOUS PACING PATCHES (suitable for Equipment in .)
-
-
-
... More
CRYO CATHETERS (AND ACCESSORIES)FOR ABLATION OF ARRHYTHMIAS IN CHILDREN AND ADULTS –
-
-
-
... More
Leadless Pacemaker with accessories
(VVIR) mode
USFDA/PMDA approved
-
-
-
... More
Leadless Pacemaker with accessories
(VVIR) mode
CE approved
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements