Rajcomp Info Services Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajcomp Info Services Limited - RISL Tender

Works
Eprocure
Opening Date15 Jun 2018
Closing Date14 Jul 2018
Tender Amount₹ 5,80,00,000 
Notes
Download

Costs

Summary

Request for Proposal for Construction of Incubation Center.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIB REFRENCE NO. F3.3(219)/RISL/Pur/2018/2334 Date 07.06.2018
Request for Proposal (RFP) Document for Construction of Incubation Center at Jodhpur.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting of Trees up to 6ft girth and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

1

-

-

... More
Cutting of Trees up to 3ft girth and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

5

-

-

... More
EARTH WORK EXCAVATION All types of soil except hard rock but including weathered disintegrated ordinary rock, compacted soil (upto 1.5m deep) Earth work excavation in limited sections by mechanical means (hydraulic excavator) / manual means over areas (upto 1.5m deep) including dewatering if water is encountered, providing sideshoring/shuttering if required, segregating the excavated earth in to serviceable and unserviceable earth; stacking the serviceable earth separately for enabling reuse for back filling or any other use as directed, carting away unserviceable earth and disposing off beyond the site at dumping spots / unobjectionable places in a proper manner with all leads. The rate shall includes the preparation of uniformly compacted surface at the foundation level as specified and as directed. Any approval / permission required to dispose is to be obtained by the Contractor.

385

-

-

... More
Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)

500

-

-

... More
Backfilling of soil sources outside the plot Filling with approved quality murrum brought from sources outside the plot. Providing and filling in foundations, below plinth, low lying areas, under tanks, trenches, grade slabs, etc with approved quality murrum including transporting from approved borrow areas, loading, unloading and spreading in layers not exceeding 200 mm thickness including watering, ramming, consolidating to attain specified compaction (95%) at optimum moisture content, levelling to required levels and slopes, etc. complete as directed and specified as under, with all lead and lift.

410

-

-

... More
CONCRETE WORK

-

-

-

... More
Plain cement concrete - M15 grade Providing & laying of M15 concrete plain cement concrete (PCC) with necessary slopes as specified for levelling coarse for any thickness and all depths & heights using graded coarse aggregates 20 mm and down graded as specified and directed. ( including setting outline and level with calibrated survey instruments, mixing, vibrating, Shuttering, curing etc).

78.5

-

-

... More
Reinforced cement concrete - M25 grade Providing & laying at all depths & heights from FGL of reinforced concrete(RCC) work for all types of foundations, pedestals,columns, ladder foundations, gates, beams, slabs, and ducts, etc., using 6mm to 20mm size graded aggregates as per approved design mix, manufactured and supplied at fully automated/manual batching plant at site with Ordinary Portland Cement (OPC ), as per drawings and specifications for grade as mentioned below, including admixtures (if required) in recommended proportion to accelerate or retard setting of concrete , uniform workability with out reducing strength as specified and directed. (including mixing, shuttering , scaffolding, vibrating, curing etc to complete the works. M 25 Concrete- As per Approved Design Mix

950

-

-

... More
Supply and laying of high yield strength deformed bars - FE500d Supply and laying of high yield strength deformed bars – Steel bars (Fe 500d grade as per IS 1786:2008) of different diameters for RCC works:- The scope includes supply, cutting and bending to required sizes and shapes, placing them at required location at all levels and position, as per the approved design with cover blocks of approved material and size, then tying with binding wire 18 gauge. The rate shall include cost of steel bars, conveyence cost, overlaps, couplings, welding joints, chairs, spacer bars, binding wire, cover blocks,wastages and all labour charges completed as per drawings, specification and directed.

160

-

-

... More
MASONRY AND PLASTERING WORKS

-

-

-

... More
Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in ::Cement Mortar 1:6 ( 1-Cement : 6-Sand).

300

-

-

... More
Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand).

150

-

-

... More
Providing and constructing brick masonry works confirming to IS 13757, having crushing strength not less than 150Kg/Sqcm in cement mortar (1:5). Immersing the bricks in water before use in all necessary projection splays cutting, circular moulding, corbelling etc.including cost conveyance, taxes & royalties, loading and unloading of all materials & cost of all labours, scaffolding , watering & curing , sundries, T & P etc. complete as per the direction of EIC.

-

-

-

... More
230 mm thick masonary in cement mortar 1:5 from height upto 15 m above plinth.

325

-

-

... More
115mm thick brick masonry with CM. 1:4 including providing reinforcement at every 1.0m height with 2 numbers of 8 mm dia. and distribution 6 mm dia at 300 mm centre to centre in all locations and heights .(including the cost of Reinforcement)

416

-

-

... More
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :12 mm thk. The rate is inclusive of work up to G+4 Level including scaffolding.

2282

-

-

... More
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. The rate is inclusive of work up to G+4 Level including scaffolding.

4000

-

-

... More
6mm thick cement plaster to ceiling of mix 1:3 (1 cement : 3- fine sand ). The rate is inclusive of work up to G+4 Level including scaffolding.

500

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :

100

-

-

... More
Filling of sunk portion of roof with earthen pots of required height including filling voids with 1:3:6 light concrete, using brick bats complete levelling and dressing the surface by 50mm thick cement concrete 1:2:4 as per specification.

50

-

-

... More
Providing & fixing precast cement concrete coping 1:2:3 mix 50mm thick complete as per direction.

200

-

-

... More
Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete.

20

-

-

... More
Grading roof for water proofing treatment with water proffing compound. Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size)

50

-

-

... More
Providing and applying 20mm thick sand faced plaster to all external surfaces(walls, parapet wall, canopy etc.) at all levels in two coats, 12 mm thick average base coat in cement mortar 1:5 and 8 mm thick finish coat in cement mortar 1:4 using fine sand for finish coat, including preparation of surface, to uniform texture, staging, double scaffolding, curing, etc complete including bands, grooves, drip moulds wherever specified and directed

1654

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for 4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners, junction with polymer mixed slurry.

50

-

-

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @ 0.253 kg/sqm. b) laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm . c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around d) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured

650

-

-

... More
FLOORING

-

-

-

... More
GRANITE FLOORING FOR STAIRCASE Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.

95

-

-

... More
VITRIFIED TILE FLOORING Providing and laying Vitrified tile flooring of size 600mm x 600mm of approved make set in cement slurry over 1:4 cement mortar bed of 35mm average thickness at all levels. Joints between tiling to be filled with grout of approved shade as per manufacturers specifications. Rate to include cost for laying tiles to approved pattern, design as directed by Architect, including surface cleaning, cement mortar, curing, acid wash, etc., and protecting the flooring with polythene sheet and pop overlay till hand over, Consider basic rate of tile at Rs. 600/-Smt.

1770

-

-

... More
ANTI SKID CERAMIC TILE FLOORING Specs same as item no 5.2 as above but using 300mm x 300mm Anti skid Ceramic tile of approved make.

72

-

-

... More
KOTA FLOORING Providing and laying 20mm to 25mm thk kota slab flooring in utility room as per pattern indicated in drawing set in cement slurry over 1:4 cement mortar bed of 35mm average thickness in all levels. Joints in the flooring to be filled with grout of approved shade as per manufacturers specifications. Quoted rate to include the cost of curing, polishing, protection with polythene sheet and POP overlay till hand-over.

260

-

-

... More
Providing and fixing of precast concrete interlocking blocks of M 30 grade 60mm thick manufactured from fully computerised automatic stationery hydraullic vibropressed machine and fully computerised automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead, Lifts and taxes. General specification of blocks: 1) Shape as defined by Engineer incharge 2) Tensile splitting strength and braking load as per BS 6717:2001 3) Color: Grey cement natural colour 4) Variation in dimension: Less than 1.6mm. 5) Variation in thickness: Less than 3.2mm 6) Abrasion: As per BS: 6717:2001

2500

-

-

... More
Providing and fixing of S.S. Railing work made out of s.s. und pipe dai 50 mm rail and vertical 40 mm dai with canting of tube 20mm dai. All material shall be 304 grade. Fixing shall be nut bolt, screw as required at site of work with 5mm glass ataching in required frame as per drg. and design and direction of engineer incharge.

100

-

-

... More
Providing and fixing of uPVC Sliding windows manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 80 x 52mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.( With mesh shuter )

50

-

-

... More
Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure 'A' :35 mm thick . Decorative teak veneer one side.

50

-

-

... More
Providing and fixing steel gate,grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide

1500

-

-

... More
Providing & Supplying temperory unskiled labour for purpose of cleaning debris etc.

60

-

-

... More
P&F double action hyraulic floor spring of approved brand and manufacture IS:6315 marked, for doors including cost of cutting cfloors as required, embedding in floors and stainless steel cover plates with brass pivot and single piece M.S.

10

-

-

... More
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement :2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in Charge.

300

-

-

... More
Drilling with core cutting machine in RCC beams,slabs,floorsetc.,for laying pipes and rendering the same in RCC 1:2:4 finishing the same to the satisifaction of the owner or his authorised representative etc.,including nominal reinforcement wherever required,complete,at all levels The quote shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes upto 250mm max depth at all heights & levels

25

-

-

... More
Providing and fixing bright finished Mortice lock of approved make Godraj or equivalent with pair or CP handles for door with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge.

20

-

-

... More
Providing and fixing pessed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4 (M 15 grade)complete as directed by Engineer-in- charge:Profile E

55

-

-

... More
DADO and stone work

-

-

-

... More
Exposed face machine cut Stone work (machine cut edges) for Wall cladding/ Veneering work up to 16 m height with 20 to 30 mm thick Pink Sand stone (Bansi Paharpur) /White sand stone (Jpdhpur stone)and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid separately). The rate is inclusive of work up to G+4 Level including scaffolding.

2500

-

-

... More
Providing and fixing stone jali 50 mm thick Jodhpur white sand stone as per ornamental design to be fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.

150

-

-

... More
Providing and fixing decorative Jodhpur stone arches of size upto 1800 x 1350 75mm thk to be fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 with an admixture of pigment matching the stone shade.

50

-

-

... More
Providing and fixing decorative Jodhpur stone columns of size upto 200 x 1800

100

-

-

... More
Providing and fixing decorative Jodhpur stone wall brackets upto 500 x 500 mm in length x height

200

-

-

... More
CERAMIC TILE DADO Providing and fixing of Ceramic tile dado in toilets using 300mm x 600mm size cemamic tile of Kajaria make or approved equivalent set in CM 1:4 with 10mm thick cement backing as per pattern indicated in the drawing. Quoted rate to include the cost of making cut-outs for electrical outlet and cost of filling the joints in dado with approved grout tinted to match the dado, curing.

280

-

-

... More
MISS. STONE WORKS and Toilet work

-

-

-

... More
GRANITE PARTITIONS FOR URINALS Providing and fixing pre-polished BLACK GALAXY granite urinal partition of size 600mm x 850mm H formed out of 19mm thk granite fixed cut as per detailed drawing. Granite partition to be ground on the edges to form full round and polished to gloss. Granite partition to be fixed to existing block masonry wall by embedding into the same upto 75mm deep & fixed with MS angle cleats & anchor fasteners.

10

-

-

... More
Supply and fixing in position GREENLAM STURDO, ALP or equivalent brand Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria,water, chemical, scratch and impact resistant 12mm thick solid high pressure compact laminate panels including doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard).The compact lamination should have Green Guard Certificate. It should be anti bactrial (certified by recomnded Test House). This also includes providing and fixing in position necessary hardware made out of Alluminium (Grade-6063-T6) & SS 304 GRADE With Alluminium Supporting systems (1) Door Knob, (2) Gravity hinges, (3) Latchlock indicators, (4) Top rail, (5) Coat Hooks, (6) U-Channels, (7) Door stopper channel, (8) SS Adjustable foot, (9) Noise Deafening Tape etc., (10) Screws (Stainless steel in 304 Grade with satin finish) & wall plugs. The adjustable foot support the pilaster and its based is anchored to the floor with stainless stell & nylon plug fixed in to ground, there U channel are used to attached the divider pannels to the wall. The alluminium toprail coated in natural anodised color to used to fix the pilaster at the top. All aspects specified by the manufactures,Greenlam Sturdo ALP orequivalent company.

5

-

-

... More
Toilet Cubicle with standard dimension Front 12mm thick with 2145mm Height x 1000mm Width (Door Size 600mm x 1830mm), Partition 12mm thick 1550mm Depth x 1980mm height (Including gap of 150mm),which includes 600mm door size width L type.

5

-

-

... More
Toilet Cubicle I-Shape (Front Partition) with standard dimension of 12mm thick, 2145 mm Height x 1000mm Width which includes (600mm x 1830mm door size width).

5

-

-

... More
GRANITE SILL Providing, cutting and laying 200mm wide 19mm thick pre-polished J WHITE GRANITE sill as per pattern indicated in drawing set in cement slurry over 1:4 cement mortar. Joints in the sill to be filled with approved grout of approved shade as per manufacturers specifications. Quoted rate to include the cost of curing, protection with polythene sheet till hand-over.

40

-

-

... More
GRANITE COUNTER FOR WASH BASIN Providing and fixing counter for wash basin of size 600mm deep formed out of 19mm thick pre-polished BLACK GALAXY granite with pre-cut opening for wash basin. The counter to have 100mm high fascia of 19mm thick polished Jet Black granite & all the edged of counter to be ground to form full round and polished to gloss. The exposed sandwiched granite to consist of 4mm groove as per detail drawing. The counter is fixed on existing masonry wall and power coated MS brackets as detailed. Ref dwg for fixing details.

5

-

-

... More
PAINTING WORKS

-

-

-

... More
INTERIOR FINISHING (A) Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (B) Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.

2782

-

-

... More
EXTERIOR FINISHING Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/10 sqm

1654

-

-

... More
ELECTRICAL

-

-

-

... More
Wiring

-

-

-

... More
Wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FR insulated unsheathed flexible copper conductor 1.1kV grade and 1.5 sq.mm FR insulated unsheathed flexible earth copper conductor 1.1 kV grade (IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swg M.S.modular box, 6 A modular type switch with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & recommended make.

-

-

-

... More
One point controlled by one no 6 A switch

80

-

-

... More
Group of two or more points controlled by one no 6 A switch

30

-

-

... More
Wiring for Twin controlled Light point with 2 x 1.5 Sqmm FRLS PVC insulated, copper conductor Multistrand Flexible wires in surface/ recessed Medium duty PVC conduit & its accessories including the cost of cutting/ making good chases in brick work and including the cost of Supplying and fixing of 2 nos MS boxes & fixing of 2 nos 6 Amp Two way Modular type switch, grid plate, modular cover plate & and also include cost of loop earthing with 1.0 Sqmm FRLS PVC insulated, Copper conductor multistrand Flexible wires Complete as required

6

-

-

... More
Wiring of 3 pin 6 amp. Light plug point with 2.5 sq. mm FR insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swg M.S.modular box, 6 A modular type switch and modular socket outlet with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & recommended make. (Raw Power).

-

-

-

... More
On board

40

-

-

... More
Wiring of 3 pin 6 amp. Light plug point with 2.5 sq. mm FR insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swg M.S.modular box, 6 A modular type switch and modular socket outlet with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & recommended make..

-

-

-

... More
One 6 A socket controlled by one 6 A switch (Raw Power up to 1 mtr)

70

-

-

... More
One 6 A socket controlled by one 6 A switch (Raw Power up to 5 mtr)

40

-

-

... More
Wiring of 3 pin 6 amp. Light plug point with 4.0 sq. mm FR insulated unsheathed flexible copper conductor 1.1 kV grade and 2.5 sq.mm FR insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swg M.S.modular box, 6 A modular type switch and modular socket outlet with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & recommended make.

-

-

-

... More
Two 6 A socket controlled by one 6 A switch (UPS Power up to 1 mtr).

70

-

-

... More
Two 6 A socket controlled by one 6 A switch (UPS Power up to 5 mtr).

40

-

-

... More
Wiring of 5 pin 16 amp. Power plug point with 2.5 sq. mm FR insulated unsheathed flexible copper conductor 1.1 kV grade and 2.5 sq.mm FR insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swg M.S.modular box, 16 A modular type switch and modular socket outlet with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & recommended make (up to 4 mtr).

21

-

-

... More
Wiring of 5 pin 16 amp. Power plug point with 4.0 sq. mm FR insulated unsheathed flexible copper conductor 1.1 kV grade and 2.5 sq.mm FR insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) including the cost of ISI marked Medium duty PVC conduit in surface / recessed & it's accessories, 18 swg M.S.modular box, 16 A modular type switch and modular socket outlet with modular grid plate & cover plate, zinc plated / brass screws, cup washers, bushes check nuts, making connections, testing etc. as per specification, drawing & recommended make (up to 4 mtr).

20

-

-

... More
S&F following sizes of ISI marked Medium duty PVC conduit along with heavy duty accessories in surface /recessed using saddles, clamps, fasteners as required including cutting the wall and making good the same as per specification, drawing & recommended make. (for Electrical)

-

-

-

600

-

-

200

-

-

150

-

-

... More
Providing and fixing of following sizes of MS channel made of 14 guage sheet metal with all accessories as required for fixing on floor complete as required including providing junction boxes, cutting the floor etc. as required.

-

-

-

... More
200 mm x 40 mm (3mm thick cover)

25

-

-

... More
150 mm x 40 mm (3mm thick cover)

30

-

-

... More
100 mm x 40 mm (3mm thick cover)

40

-

-

... More
65 mm x 40 mm (3mm thick cover)

60

-

-

... More
Supplying, Receiving, Storing and fixing in position at site, floor outlet boxes having a size of 450 x 450 x 60 mm fabricated using 14 Gauge White CRCA Sheets complete with powder coating with metal treatment done.

1

-

-

... More
Supplying, Receiving, Storing and fixing in position at site, floor outlet boxes having a size of 350 x 350 x 50 mm fabricated using 14 Gauge White CRCA Sheets complete with powder coating with metal treatment done.

2

-

-

... More
Supplying, Receiving, Storing and fixing in position at site, floor outlet boxes having a size of 250 x 250 x 50 mm fabricated using 14 Gauge White CRCA Sheets complete with powder coating with metal treatment done.

4

-

-

... More
Supplying, Receiving, Storing and fixing in position at site, floor outlet boxes having a size of 150 x 150 x 50 mm fabricated using 14 Gauge White CRCA Sheets complete with powder coating with metal treatment done.

8

-

-

... More
Supplying, Receiving, Storing and fixing in position at site, floor outlet boxes having a size of 100 x 100 x 50 mm fabricated using 14 Gauge White CRCA Sheets complete with powder coating with metal treatment done.

12

-

-

... More
Supplying and drawing FR insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.

-

-

-

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

400

-

-

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

800

-

-

... More
2 x 6.0 sq. mm. + 1 x 4.0 sq. mm.

300

-

-

... More
4 x 6.0 sq. mm. + 1 x 4.0 sq. mm. (DB supply)

150

-

-

... More
4 x 10.0 sq. mm. + 1 x 6.0 sq. mm. (DB supply)

100

-

-

... More
4 x 16.0 sq. mm. + 1 x 6.0 sq. mm.

100

-

-

... More
4 x 50.0 sq. mm. + 1 x 25.0 sq. mm. (UPS supply)

25

-

-

... More
P & F 2.5 sqmm 6 way (3 pole) 16 amp nylon 6.6 cage clamp screw less copper connector including making connection etc as required

25

-

-

... More
P & F 4.0 sqmm 6 way (3 pole) 32 amp nylon 6.6 cage clamp screw less copper connector including making connection etc as required

25

-

-

... More
P & F 6.0 sqmm 6 way (3 pole) 32 amp nylon 6.6 cage clamp screw less copper connector including making connection etc as required

25

-

-

... More
Supply and fixing of LED Recessed Downlighter with a minimum system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 30,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI70. The luminaire shall meet IP20 rating with THD10% and PF 0.9. The luminaire housing should made of pressure die cast aluminium with a high efficiency diffuser. The total power consumption should not exceed 18W (including driver) of make Philips /Wipro /CG.

40

-

-

... More
Supply and fixing of LED Recessed 2 x 2 Luminaire with a minimum system lumen output of 3400 lumens and a minimum system efficacy of 120 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI80. The luminaire shall meet IP20 rating with THD10% and PF 0.9 and an operating Voltage Range of 140 - 270 V. The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser .The total power consumption should not exceed 32W (including driver) of make Philips /Wipro /CG.

40

-

-

... More
P & F of IP20 LED batten type light fixture made from extruded aluminium housing suitable for moutning LED tube system non replaceable driver, Power Consumption of 22W 2200 lumens, system lumen efficiency 100 lm/Watt output, life time of 25,000 burning hours with 70% initial lumen maintained. CCT 4000°K & 6500°K of make Philips /Wipro /CG.

40

-

-

... More
Supplying, installation, testing & commissioning of 14 watt 5000K-6500K mirror light all accessories i/c connections with 3 x 1.5 sq.mm PVC insulated FR copper conductor cable etc. as reqd of Make Philips /Wipro /CG.

12

-

-

... More
P & F of IP65 IK10 rated LED bulk head type light fixture made from CRCA sheet steel housing suitable for moutning LED tube system (integral driver), Power Consumption of 10W ~ 1000 lumens, system lumen efficiency 100 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K & 6000°K of Make Philips /Wipro /CG.

8

-

-

... More
DATA & TELEPHON WORK

-

-

-

... More
S&F following sizes of ISI marked Medium duty PVC conduit along with heavy duty accessories in surface /recessed using saddles, clamps, fasteners as required including cutting the wall and making good the same as per specification, drawing & recommended make. (for CCTV / ACCESS CONTROL / DATA / VOICE)

-

-

-

100

-

-

200

-

-

... More
Supplying and drawing PVC jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam PE dielectric coaxial cable (RG-6) of approved make in existing surface or recessed conduit/casing capping including making connections as required.

100

-

-

... More
Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessorry tools for punching, stripping, crimpping and testing required as per list of make.

1200

-

-

... More
Supply and Installation of Information outlets made of high impact plastic bodyABS FR Grade with spring loaded collapsible shutters in jack Recess, suitable for Cat 6 application complying to latest ammendments EIA/ TIA 568 B.2-1 Specifications in existing modular /MS Boxes along with necessory connections as required. I/O's to have Terminator caps for toolless termination Single Outlet with required face plate, Box etc as per list of make.

60

-

-

... More
Supply , Installation, Testing and Comissioning of Rack mounted 19", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps.

-

-

-

... More
24 Ports

4

-

-

... More
Supply , Installation, Testing and Comissioning of 18U Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable

4

-

-

... More
Supply , Installation, Testing and Comissioning of Rack mounted 19", 50 Port Voice Patch panel to support latest ammendments of TIA / EIA specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Voice Cables, With Rear Cable management trays and clamps (for Voice Cabling system) Make- Amp/Molex/Penduit

3

-

-

... More
Supply , Drawing and Testing of 50 pair, 24 AWG UTP Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required (for Voice Cabling system) Make- Amp/Molex/Penduit

160

-

-

... More
Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , Cat 6 UTP, flexible , 0.5 mtrs Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief transparent boots as per TIA /EIA 568 B.2-1 Specifications (for Voice Patching purpose) (Makes: Molex, AMP, Penduit)

100

-

-

... More
SITC of Managed 24 port Layer-2 Intelligent Ethernet Switch providing 24 x 10/100/1000 Fast Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software . ( FOR DATA)

3

-

-

... More
SITC of Managed 24 port Layer-2 POE (370 watt) Intelligent Ethernet Switch providing 24 x 10/100/1000 Fast Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software . ( FOR CCTV)

1

-

-

... More
P & F following size hot dip galvanized M.S. box with earthing terminal in recess/ surface suitable for accessories as required.

-

-

-

... More
100 mm X 100 mm X 60 mm deep

175

-

-

... More
P & Fixing of following size modular type mounting grid plates with cover plates

-

-

-

... More
1 /2 Module

175

-

-

... More
P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as per list of make.

-

-

-

... More
T.V. coaxial socket

4

-

-

... More
SITC of IP Based 2MP Motorised Vari-Focal Vandal Proof Dome Camera with alumium alloy wall mounted kit with junction The camera shall be of 1/2.8" Progressive CMOS, ICR, 0lux with IR, 1920x1080, 25fps(P)/30fps(N), Motorised 2.8~12mm VF lens, H.264/MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: up to 30m, Support on-board storage up to 128GB (SD card not included), Intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open Standard to support ONVIF (PROFILE S, PROFILE G), PSIA and CGI Protocol, Metal Housing, Vandal-proof housing up to IK10 rating, IEC60068‐275Eh, 20J; EN50102, IP67, DC 12V & PoE, Oerating Conditions: ‐ 30 °C – 60 °C or better. IK10 test report to be provided, UL / CE / FCC certified.

10

-

-

... More
SITC of IP Based 2MP IR Bullet Camera: 1/2.8" Progressive CMOS, ICR, 0lux with IR, 1920x1080:25fps(P)/30fps(N), 4mm / 6mm lens (As persite requirement), H.264 / MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: up to 50m, Intrusion detection, Line crossing detection, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open Standard to support ONVIF (PROFILE S, PROFILE G), PSIA and CGI Protocol, Metal Housing, Vandal-proof housing IP67, DC 12V & PoE. Complete with junction box for cable management. Oerating Conditions: ‐30 °C – 60 °C or better, UL / CE / FCC certified.

2

-

-

... More
SITC of All in one Server combination with OS, advanced iVMS and inbuilt 96 TB Storage device: with Intel Xeon 4 core (64bit) E3-1225 V5 CPU @ 3.3Ghz or better, 8GB RAM, ONVIF based VMS software and Windows 10 or better on independent drive. Should support up to 256 cameras for live view, recording & Playback, VMS and storage device should be located on independent mother board with Network interfaces, serial interfaces, HDMI outputs, 756 MBPS or better incoming & outgoing bandwidth, support up to 12Mp cameras, support ANPR cameras with generating reports, Intrusion detection, Line Crossing Detection, Face Detection, People Counting features, ANR technology, N+1 hot spare system, Should have minimum 4 Sata HDD slots for OS and 16 HDD Sata type slots for recording, each slot should support upto 8TB HDD, e-Sata interface, mini SAS interface, 4 x 1Gbps network interface (separately for server board and storage board)  RS232 , RS484, RAID 0,1,5,6,10, Alarm in/out: 16/08 or better, dual independent HDMI output, Two Way audio, e-Map,  number of event logs up to 100,000, dual power supply, 19" Rack mount chassis. UL, CE and FCC compliance.

1

-

-

... More
Supply Installation Testing and Commissioning of of 32Ch NVR with 08 Sata with 256 Mbps incoming Bandwidth, dual Operating System, ANR technology for storage reliability, ONVIF based third party cameras should be connected, 4K output, Up to H.265 Compression Support, up to 8MP Cameras supported for live view and playback, able to decode 08 cameras @ 1080p, 24 TB Surveillance HDD ( each of 6 TB), 08 Sata slots to support up to 6TB each, two-way audio, dual 10/100/1000mbps RJ45 Network, USB 3.0 port, Alarm In/Out (16/4), Operating Conditions: ‐10 °C – 50 °C or better, dual power supply, 19" rack mounted chassis. Certificate of Compliance: UL/ CE / FCC. including making connection etc as required. The NVR should be of the same make of cameras for the smooth working of the system.

1

-

-

... More
Supply, Installation & Commissioning of Workstation latest Intel® i7 4th Generation, processor, Intel Chipset motherboard, 16 GB DDR3 RAM, 500 GB SATA HDD at 7200 rpm, Graphic card with 1 GB dedicated RAM with display ports/DVI/ HDMI port, DVD writer, Giga LAN Card, Keyboard, optical Mouse.

1

-

-

... More
SITC of 17'' Screen for viewing for Storage.

1

-

-

... More
SITC of 55'' Flat Screen HD Profesional LED suitable for 24x7 operation with remote control and wall mount unit / floor stand complete with making connections etc.

1

-

-

... More
Supply , Drawing and Testing of 4 pair, Cat 6A FTP - Foiled Twisted Cable as per latest ammendments of TIA /EIA 568 C.2 Specifications in existing MS/PVC Conduits/ HDPE pipe with ferruling at both ends for identification with necessorry tools for punching, stripping, crimpping and testing required. (CCTV cable)

400

-

-

... More
SITC of FM Connector (specifically designed for tool less connection for CAT6 FTP / Outdoor cabling system, can be usable for multiple times) required for both end connectivity to take care for Data connectivity as well as Power for the cameras, The FM connector shall be used for earth connectivity at both end.

24

-

-

... More
Supplying and drawing ATC bunched conductor, PVC/PE insulated, PVC SHEATHED 8 core ACCESS control cable.

350

-

-

... More
SITC of Fingerprint and RF Card based Access Controller with LCD and Keypad having Optical Fingerprint and RF Card based Reader with EM Proximity Card Reader Module (Low Frequency), Support EM Prox, Mifare Smart and HID iCLASS Card Module, Dot-Matrix LCD and Touchsense Keypad, Built-In Interfaces Such as USB, Door Lock, Door Sense, Exit Reader, Exit Switch, Ethernet, Aux Input and Aux Output Port, Mobile Broadband (3G/2G) Connectivity on USB, Access Control, Time-Attendance and Cafeteria Application, 5,00,000 Events and 9,600 Fingerprint Templates, 4 LEDs and Buzzer with 2nos licence dongle.

3

-

-

... More
The Access Controller should have software for 100 user expandeble up to 500 user, with Comprehensive Time-Attendance and Leave Management Software Module, Comprehensive Access Control Management

1

-

-

... More
The Access Controller should have user licence.

100

-

-

... More
SITC of lock with bracket of 600lbs electromagnetic lock unmonitored type 12V LED Lamp.

6

-

-

... More
SITC of Exit Button of size 3 inches x 3 inches .

3

-

-

... More
SITC of IP54 rating Boom Barrier that shall open in case of an impulse with the use of a valid card/Push Button. The barrier shall close either after the vehicle has passed or after an adjustable hold-open time in case the vehicle chooses not to pass through. Appropriate sensors shall be used for this purpose. It shall meet the following specifications.

1

-

-

... More
The barrier shall use a Blockable DC High Torque Drive in combination with CAN bus communication standard interfaced Controller. It shall offer LCD Display & Graphic User Interface for easy control setting. Possibility for integration via standard user interfaces. The Booms shall be extruded aluminium with round shape & having swing-away flange. 100% duty cycle, will work on vide voltage range 85 – 264 V AC, Opening & Closing Time 1.30 Secs for length up to 3 Meter, Operating Temperature -30 Degree Celsius to + 55 Degree Celsius, Barrier Housing Unit: Powder Coated Boom: Powder Coated White RAL 9010 with Red reflective strips. Housing shall be modular & constructed of Aluminium with Base frame in SS-304 for high protection against corrosion. All Housing and internal parts will be rust & corrosion free metals or alloys of high strength with suitable Epoxy coating as applicable.

-

-

-

... More
The controller shall have minimun 8 digital input, 4 digital output, 6 relay output. The barrier shall have auto Swing Away Flange, 10/10 Beaufort rating (Boom not swaying from wind velocity), The barrier shall have MCBF- 10 Million Cycles, MTBF- 50,000 Hours, MTTR- 30 Minutes. The barrier shall have Impact detection without additional sensors, such as pressure sensitive device; with possibility of automatic reversing or safe stop after impact detection,The barrier shall have Selection of behaviour in case of power failure: Stay locked / stay unlocked / automatic opening of Magnetic Autocontrol / Automatic System.

-

-

-

... More
DISTRIBUTION BOARDS

-

-

-

... More
P&F Recessed/ Surface mounting heavy duty horizontal type TPN double door sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , with 3nos ELCB / RCBO, testing etc. as per approved make.

-

-

-

2

-

-

4

-

-

... More
12 Way

4

-

-

... More
P&F Recessed/ Surface mounting heavy duty horizontal type SPN double door sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as per approved make. ( DB for lift)

-

-

-

... More
12 Way

2

-

-

... More
P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as per approved make.

-

-

-

... More
Single pole MCB

-

-

-

... More
6 A to 32 A rating

200

-

-

... More
Double pole MCB

-

-

-

... More
32/40 A rating

2

-

-

... More
Four pole MCB

-

-

-

... More
32 A rating

2

-

-

... More
40A to 63 A rating

10

-

-

... More
P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required

-

-

-

... More
40 A DP RCCB 30 mA

12

-

-

... More
63 A DP RCCB 30 mA

10

-

-

... More
P & F Recessed / Surface mounting heavy duty horizontal type 16 swg sheet steel cable end box phophatised / powder painted complete with cover plate, nut bolt, to be fixed at top / bottom of the DB to keep extra cable in the end box etc as required to cover the entire lenght of distribution board as mentioned in the above items.

-

-

-

... More
Suitable for SPN DB

2

-

-

... More
Suitable for TPN DB

10

-

-

... More
EARTHINGS

-

-

-

... More
Supply installation testing and commissioning of maintenance free GEL earthing dual pipe technology of 3 mtr long 80 mm dia with the adequate galvanization of 300 microns filled with special conducting compound, 50 Kgs of Moisture Booster to retain the moisture duly tested & certified by CPRI Laboratory. The earthing pit shall be provided with suitable sturdy test well for observation as per approved make.

12

-

-

... More
Supply installation testing and commissioning of maintenance free GEL earthing dual pipe technology of 2 mtr long 50 mm dia with the adequate galvanization of 300 microns filled with special conducting compound, 25 Kgs of Moisture Booster to retain the moisture duly tested & certified by CPRI Laboratory. The earthing pit shall be provided with suitable sturdy test well for observation as per approved make.

4

-

-

... More
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess on SMC insulator including riveting, soldering, saddles, making connection etc. as required.

-

-

-

... More
8 SWG Cu wire

200

-

-

... More
50mm x 6mm copper strip duly PVC sleeved

100

-

-

... More
32mm x 6mm copper strip duly PVC sleeved

200

-

-

... More
S & Laying following size flexible earth wire/strip of 2.0 mtr length for connecting earth strip to DG neutral terminal including riveting, soldering, saddles, making connection etc. as required.

-

-

-

... More
30mm x 5mm copper strip

4

-

-

... More
Supply and Installation of 30 x 2mm PVC sleeved copper tape down conductor duly fixed on DMC/SMC insulator with clamp nut bolt etc.

60

-

-

... More
Supply and installation of copper test link joint connector in the IP 55 weather proof box including making connection etc complete.

1

-

-

... More
Supply Installation testing and commissioning of external lightening protection system based on proactive Early Streamer emission (ESE) technology. Device shall comply NFC 17-102 and UNE 21186 standards. The device shall be mounted at least 4-5 meters high clear to highest point on the roof top with proper mounting arrangement.

-

-

-

... More
ESE for radius 50 mtr for level 1 protection

1

-

-

... More
CABLING WORK

-

-

-

... More
P/Laying P.V.C. insulated & P.V.C. sheathed armoured cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I on cable tray, including cable termination, cable luges, cable gland, making connection, testing etc. as per specification, drawing & recommended make.

-

-

-

... More
4 core 16 sqmm

75

-

-

... More
3.5 core 35 sqmm

75

-

-

... More
3.5 core 120 sqmm

100

-

-

... More
3.5 core 185 sqmm

100

-

-

... More
3.5 core 240 sqmm

50

-

-

... More
Supply & installation of cable identification plates duly secured to cables for identification suitable for cable sizes taken in the BOQ.

35

-

-

... More
SITC OF 100 Amp, FP, 35 KA, MCCB, having Thermal Magnetic trip unit with adjustable overload , short circuit & earth fault protection

2

-

-

... More
SITC OF 160A FP, 35 KA, MCCB, having Thermal Magnetic trip unit with adjustable overload , short circuit & earth fault protection

2

-

-

... More
Supply and laying in ISI marked RCC hume pipe NP 3 as per IS - 458-1988 with coller etc including making trench & refilling the same after covering the pipe with cement concrete mixture complete in all respect as per specification.

-

-

-

... More
150 mm dia

50

-

-

... More
Making of 900x900x900 mm masonary chamber made out from 225 mm thick brick wall & cement concrete plaster and covered with ferro cement cover complete in all respect.

1

-

-

... More
Making of 600x600x600 mm masonary chamber made out from 225 mm thick brick wall & cement concrete plaster and covered with ferro cement cover complete in all respect.

3

-

-

... More
Making of 300x300x300 mm masonary chamber made out from 225 mm thick brick wall & cement concrete plaster and covered with ferro cement cover complete in all respect.

2

-

-

... More
Supplying, handling, laying, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and sheathed copper conductor armoured stranded control cable complete with saddles, clamps etc. as required and as per specifications. (Cost shall be inclusive of supplying and making terminations using single compression brass glands & copper lugs).

-

-

-

... More
2C 2.5 sqmm

50

-

-

... More
10C 2.5 sqmm

50

-

-

... More
Fabricating & installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting

-

-

-

... More
150mm x 50mm x 1.6mm

40

-

-

... More
300mm x 50mm x 2mm

40

-

-

... More
MEDIUM VOLTAGE PANELS

-

-

-

... More
MAIN LT PANEL

-

-

-

... More
Supply, installation, testing & commissioning of cubicle type totally enclosed free standing type dust & vermin proof Main Panel made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming ACB / MCCB / SFU & outgoing MCB / MCCB / SFU , All the MCCB should be with Rotary handle, Four Pole Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing, enclosed specifications and recommended makes.

1

-

-

... More
INCOMING FOR ISOLATOR PANEL

-

-

-

... More
800 Amp, FP, 50KA, EDO,ACB ,having Microprocessor trip unit , Digital display with adjustable overload , short circuit , Instantaneous & earth fault protection. ACB trip unit with indication of fault LED indications (OL,SC,EF etc.) , in-built Zone selective interlocking , thermal memory , approx. % loading information ,4NO/NC auxilary conacts ; min. current , voltage & energy parameters on display with last 5 trip history, with communication port upgradable to ethernet communication (either built-in or with external gateway for each breaker) for ready BMS/EMS connectivity.

1

-

-

... More
3P+N Type1 + Type2 SPD with inbuilt health indicator, response time 25 ns, Imax 40 KA, Voltage Protection Level 1.5 KV, shall be used at the incomer side of the panel with 32 Amp FP C curve MCB

1

-

-

... More
INCOMING FOR DG-1 (250KVA)

-

-

-

... More
400 Amp, FP, 35 KA, MCCB, having elctronic trip unit with adjustable overload , short circuit , Instantaneous & earth fault protection. Trip unit with LCD display ; Zone Selective Interlocking; rms current measurement ; fault indication of overload, short circuit, instantaneous & earth fault indication ;fault & event history, Ready LED , Overload Prealarm and Overload LED; with communication port upgradable to ethernet communication for ready BMS/EMS connectivity

1

-

-

... More
400 Amp, FP, AC3 utilisation catagary power contactor, having 415 volt operating auxiliary coil fitted with suppressor & 2NO+2NC block

1

-

-

... More
BUSBAR

-

-

-

... More
1200 Amp, FP, Electrolytic grade Al busbar for main ACB / MCCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

1

-

-

... More
400 Amp, TP with neutral link, 35KA, MCCB having electronic release with adjustable short circuit and adjustable overload (0.5 to 1In) protection

2

-

-

... More
250 Amp, TP with neutral link, 25KA, MCCB having Thermal Magnetic release with short circuit and adjustable overload (0.7 to 1In) protection

2

-

-

... More
100 Amp, TP with neutral link, 25kA, MCCB having Thermal Magnetic release with short circuit and adjustable overload (0.7 to 1In) protection

4

-

-

... More
40 Amp, FP, 10KA, MCB

2

-

-

... More
63 Amp, FP, 10KA, MCB

2

-

-

... More
METERING SECTION FOR X'MER

-

-

-

... More
DIGITAL LCD Energy meter (64 samples/cycle) of rating with 3nos 800/5A class 0.5s as per IEC 62053, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD, Individual harmonics up to 15th level etc. parameters. Meter shall comply to IEC 61557-12 for Performance measuring and monitoring devices (PMD).The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB

1

-

-

... More
LED type RYB indication lamp duly protected by 2A MCB

2

-

-

... More
PROTECTION SECTION FOR X'MER

-

-

-

... More
Under voltage & over voltage protection relay for protection

1

-

-

... More
METERING SECTION FOR DG -1 (250 KVA)

-

-

-

... More
DIGITAL LCD Energy meter (64 samples/cycle) of rating with 3nos 400/5A class 0.5s as per IEC 62053, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD, Individual harmonics up to 15th level etc. parameters. Meter shall comply to IEC 61557-12 for Performance measuring and monitoring devices (PMD).The energy meter should have communication modbus RS 485 port & required hardware & software for communication duly protected by 2A MCB

1

-

-

... More
LED type RYB indication lamp duly protected by 2A MCB

3

-

-

... More
PROTECTION SECTION FOR DG

-

-

-

... More
Under voltage & over voltage protection relay for protection

1

-

-

... More
Reverse power flow relay for protection

1

-

-

... More
APFC PANEL SECTION

-

-

-

... More
Capacitor Bank – 250KVAr (1-2-2-5-5-10-25-50-50-50-50)

-

-

-

... More
Capacitor steps:

-

-

-

... More
(a) First steps - 1 KVAr

-

-

-

... More
(b) Next two - 2 KVAr

-

-

-

... More
(c) Next two– 5 KVAr

-

-

-

... More
(d) Next one – 10 KVAr

-

-

-

... More
(e) Next one–25 KVAr

-

-

-

... More
(f) Next four– 50 KVAr

-

-

-

... More
BUSBAR

-

-

-

... More
900 Amp, TPN, Electrolytic grade Al busbar for main ACB incoming, outing & capacitor distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

-

-

-

... More
SWITCHING

-

-

-

... More
3 P, 440 V capacitor switching contactor duty AC 6b of required rating with suitable rating MCB / MCCB as per SLD

-

-

-

... More
(a) 1 KVAr with 6 Amp D curve TP MCB

-

-

-

... More
(b) 2 KVAr with 10 Amp D curve TP MCB

-

-

-

... More
(c) 5 KVAr with 16 Amp D curve TP MCB

-

-

-

... More
(d) 10 KVAr with 32 Amp D curve TP MCB

-

-

-

... More
(e) 25 KVAr with 63Amp D TP MCB 16 KA

-

-

-

... More
(f) 50 KVAr with 125 Amp TP MCCB 16 KA

-

-

-

... More
12 stage Microprocessor based APFC relay of sensitivity less than 50 ma

1

-

-

... More
LED type ON indication lamp

12

-

-

... More
Ventilation Fans with thermostat & On/Off selector switch

2

-

-

... More
Auto /Manual /off Selector Switch (3 position)

12

-

-

... More
The CT sensing of the APFC relay shall be from the incomer side of contacotr (JVVNL supply).

-

-

-

... More
All control wiring from Bus bar to MCB, capacitor duty Contactor & Capacitor bank will be of required Ratings PVC insulated flexible copper wire.

-

-

-

... More
AMF panel should be capable for one external source and 1 nos DG sets.

-

-

-

... More
Suitable PLC relay for SYNCHRONISATION cum AMF operation of two DG sets and one external source

-

-

-

... More
Digital I/P module

-

-

-

... More
Digital O/P module

-

-

-

... More
Suitable slot I/O rack with power supply

-

-

-

... More
Analouge I/P module

-

-

-

... More
KW tranducer

-

-

-

... More
EEPROM memory module

-

-

-

... More
Phase angle tranducer

-

-

-

... More
Operator interface 3" diagonal with key pad

-

-

-

... More
Communication cable from Operator interface to PLC

-

-

-

... More
Hooter for varios status annunciation

-

-

-

... More
All the software required for proper operation

-

-

-

... More
1/2 KVA online UPS with half an hour battery (SMF) back up for start operation

-

-

-

... More
1st & 2nd FLOOR PANEL

-

-

-

... More
Supply, installation, testing & commissioning of cubicle type totally enclosed free standing dust & vermin proof L T metering panel made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming ACB/MCCB & outgoing MCB/ MCCB, All the MCCB should be with Rotary handle, Dual source electronic energy meter, Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing & enclosed specifications recommended makes.

2

-

-

... More
INCOMER

-

-

-

... More
200Amp, FP,25 KA, MCCB having Thermal Magnetic release with short circuit and adjustable overload (0.7 to 1In ) protection

1

-

-

... More
3P+N Type2 SPD with inbuilt health indicator, response time 25 ns, Imax (8/20 µs) 8 KA, Voltage Protection Level 1.2 KV, shall be used at the incomer side of the panel with 32 Amp FP C curve MCB

1

-

-

... More
BUSBAR

-

-

-

... More
150 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

-

-

-

... More
OUTGOING

-

-

-

... More
40 Amp, FP, 10KA, MCB

2

-

-

... More
63 Amp, FP, 10KA, MCB

2

-

-

... More
FOR SPARE

-

-

-

... More
63 Amp, FP, 10KA, MCB

1

-

-

... More
40 Amp, FP, 10KA, MCB

1

-

-

... More
METERING SECTION

-

-

-

... More
DIGITAL LED Energy meter (32 samples/cycle) of rating with 3nos 100/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB

1

-

-

... More
LED type RYB indication lamp duly protected by 2A MCB

3

-

-

... More
AC VRF PANEL AT TERRACE FLOOR

-

-

-

... More
Supply, installation, testing & commissioning of outdoor cubicle type totally enclosed free standing dust & vermin proof L T metering panel made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming ACB/MCCB & outgoing MCB/ MCCB, All the MCCB should be with Rotary handle, Dual source electronic energy meter, Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing & enclosed specifications recommended makes.

1

-

-

... More
INCOMER

-

-

-

... More
320Amp, FP,25 KA, MCCB having Thermal Magnetic release with adjustable overload (0.7 to 1In ), & short circuit protection

1

-

-

... More
3P+N Type2 SPD with inbuilt health indicator, response time 25 ns, Imax (8/20 µs) 8 KA, Voltage Protection Level 1.2 KV, shall be used at the incomer side of the panel with 32 Amp FP C curve MCB

1

-

-

... More
BUSBAR

-

-

-

... More
450 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

-

-

-

... More
OUTGOING

-

-

-

... More
63 Amp. FP MCB, 10 kA, with 63 Amp FP 300 ma RCCB

6

-

-

... More
40 Amp. FP MCB, 10 kA, with 63 Amp FP 300 ma RCCB

4

-

-

... More
FOR SPARE

-

-

-

... More
63 Amp. FP MCB, 10 kA, with 63 Amp FP 300 ma RCCB

1

-

-

... More
40 Amp. FP MCB, 10 kA, with 63 Amp FP 300 ma RCCB

1

-

-

... More
METERING SECTION

-

-

-

... More
DIGITAL LED Energy meter (32 samples/cycle) of rating with 3nos 300/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB

1

-

-

... More
LED type RYB indication lamp duly protected by 2A MCB

1

-

-

... More
EXTERNAL LIGHT PANEL

-

-

-

... More
Supply, installation, testing & commissioning of outdoor cubicle type totally enclosed free standing double door type dust & vermin proof Kiosk Panel for outdoor application made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming ACB / MCCB / SFU & outgoing MCB / MCCB / SFU , All the MCCB should be with Rotary handle, Four Pole Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing, enclosed specifications and recommended makes.

1

-

-

... More
INCOMER

-

-

-

... More
63Amp, FP, C curve, 10 KA BC MCB

1

-

-

... More
BUSBAR

-

-

-

... More
100 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

-

-

-

... More
OUTGOING

-

-

-

... More
25Amp, FP, C curve, 10 KA BC MCB

1

-

-

... More
25Amp, FP, AC1 utilisation catagary power contactor, having 415 volt operating auxiliary coil fitted with suppressor & 2NO+2NC block

1

-

-

... More
40Amp,FP, C curve, 10 KA BC MCB

2

-

-

... More
6Amp, SP, C curve, 10 KA BC MCB

11

-

-

... More
Digital Time Switch with 2 Amp MCB for time switch bypass Arrangement

1

-

-

... More
All the accessories should be mounted on 6 mm thick bakelite sheet

1

-

-

... More
METERING SECTION FOR INCOMER

-

-

-

... More
DIGITAL LED Energy meter (32 samples/cycle) of rating with 3nos 50/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB

1

-

-

... More
LED type RYB indication lamp duly protected by 2A MCB

3

-

-

... More
UPS PANEL

-

-

-

... More
Supply, installation, testing & commissioning of cubicle type totally enclosed free standing dust & vermin proof Fire Fighting panel made out of 2.0 mm thick and partition made out of 1.6 mm MS sheet steel, suitable for 3 phase , 4 wire , 415 V , 50 Hz , AC supply complete with incoming MCCB & outgoing MCB/ MCCB, All the MCCB should be with Rotary handle, DOL Starter, Electrolytic grade Al busbar of required capacity, indication lamp etc complete as per drawing & enclosed specifications recommended makes.

1

-

-

... More
INCOMER

-

-

-

... More
200Amp, FP, 25 KA, MCCB having Thermal Magnetic release with short circuit and adjustable overload protection

1

-

-

... More
3P+N Type2 SPD with inbuilt health indicator, response time 25 ns, Imax (8/20 µs) 8 KA, Voltage Protection Level 1.2 KV, shall be used at the incomer side of the panel with 32 Amp FP C curve MCB

1

-

-

... More
BUSBAR

-

-

-

... More
300 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

-

-

-

... More
200 Amp, FP, Electrolytic grade Al busbar for main MCB outing & feeders distribution, The Bus Bar section should be covered with withdrawable Acrylic sheet for protection.

-

-

-

... More
OUTGOING

-

-

-

... More
160 Amp, FP, 16 KA, MCCB, having Thermal Magnetic release with short circuit and adjustable overload protection

2

-

-

... More
100 Amp, FP, 16 KA, MCCB, having Thermal Magnetic release with adjustable overload , & short circuit protection

1

-

-

... More
UPS CONNECTION

-

-

-

... More
THE PANEL SHALL HAVE PROVISION FOR UPS INCOMING FOR 2NOS 60 KVA UPS & OUTGOING CONNECTION FROM COMMON BUSBAR OF THE PARALLEL CONNECTED UPS.

-

-

-

... More
OUTGOING

-

-

-

... More
125 Amp, FP, 16 KA, MCCB, having Thermal Magnetic release with short curcuit and adjustable overload protection

1

-

-

... More
40Amp, FP, C curve, 10 KA BC MCB

9

-

-

... More
32Amp, FP, C curve, 10 KA BC MCB

2

-

-

... More
METERING SECTION

-

-

-

... More
DIGITAL LED Energy meter (32 samples/cycle) of rating with 3nos 200/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCBB

1

-

-

... More
DIGITAL LED Energy meter (32 samples/cycle) of rating with 3nos 100/5A class 1 as per IEC 62053-21, CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH / MD / %THD parameters. The energy meter should have communication modbus RS 485 port & required hardware & software for communication, duly protected by 2A MCB

1

-

-

... More
LED type RYB indication lamp ( Red/ Green/ Amber) for On/Off/ trip indication duly protected by 2A MCB

2

-

-

... More
TRANSFORMER WORK

-

-

-

... More
Supply, Installation,Testing and Commissioning of 500 KVA copper wound Energy efficient Level 2 as per IS 1180, 11/0.433 KV, 50 C/S, ONAN Delta-star connected, Dyn11 vector group transformer, with OLTC, RTCC, AVR including making of the x'mer plateform and placement of x'mer on the plateform, making HT / LT connection, neutral & body earth connection, control cable connection from OLTC to RTCC, & control cable from marshalling box to HT breaker etc. The losses shall be 1.510 KW at 50% load and 4.3 KW at 100% load. Inpedance of the x'mer shall be 4.5%. The tempreture rise shall be 45ºC for x'mer winding & 40ºC for x'mer oil. The OLTC shall have tap changing from +5% to -15% in the step of 1.25%.

1

-

-

... More
HT BREAKER WORK

-

-

-

... More
S & F of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid abberation marks and pasting the mat with synthetic rubber adhesive as required.

-

-

-

... More
3.3 KV, 2 mm thick with proof voltage 10 KV / 3 min. and Break Down Voltage 30 KV

6

-

-

... More
HT CABLE & ACCESSORIES WORK

-

-

-

... More
Supply, Installation, testing & commissioning of 11 KV grade Earthed Aluminium conductor, XLPE insulated armoured confirming to IS:7098 part II in trenches of size 30 cm X 100 cm as per IS:1255, in cable trays, in protective GI pipes, on pole, on structures, in coloumns,in conduits, in panels etc including all required materials such as fixing clamps, screws, cable straps, number tags etc as required. including labour atc as per specification, drawings and directions of Engineer-In-charge. Contractor should varify the length of the cable before procuring the material.

-

-

-

... More
3 core 185 sqmm armoured earthed

50

-

-

... More
Supply, Installation, testing & commissioning of End termination for 11KV, 3 core Al conductor XLPE insulated armoured cable with heat shrink termination kit including cutting, stripping of cable insulation supplying and providing the required cable end lugs, termination and other kit accessories, cable supporting clamps, straps etc including earthing of armouring etc, complete in all respect including consumables tools / equipments and labour as per specification

-

-

-

... More
Indoor end terminal for

-

-

-

... More
3 C 185 sq mm

2

-

-

... More
DG SET & ACCESSORIES

-

-

-

... More
SITC of Silent DG Set (As per CPCB norms) complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown). Engine shall have residential silencer, up to 3 M exhaust piping , electronic / Mechanical governor, Manual & electric Start ,Batteries, Engine instruments panel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mmCRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with 100mm thick glass wool(96Kg/m3)/Foam. as per IS 8183 the doors of 100 mm thick and fabricated from 1.6mm CRCA sheet packed with accoustic material, canopy fixed with axial flow fan , All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, residential silencer (isolated from main DG chamber) with protection and tripping of DG set

1

-

-

... More
Radiator Cooled & Turbo Charged /AC

-

-

-

... More
250 KVA at 0.8 pf 415V 50Hz 3-ǿ

1

-

-

... More
Supply,Installation, testing and commissioning of exhaust piping of following sizes with class B MS pipes of 5mm thick with welding joint including bends, MS pipe supports, clamps, dash fastener, nuts, bolts etc., thermal insulation with 50 mm thick layers of LRB rock wool (64 kg/m3 density) 26 SWG aluminium sheet claddings etc. complete as required and as per specifications. (The exhaust piping system shall include supply, erection, testing and commissioning of blower fan of suitable rating, associated cabling and starter panel etc. below the exhaust pipe shaft for ventilation of the shaft, if required, to ensure that the surface temperature of the exhaust pipes shall not exceed 50OC, The vendor shall get back pressure calcualtion from the OEM, suitable no of expansion bellows as per OEM standard shall be included in the piping cost).

-

-

-

... More
150 mm dia. NB

25

-

-

... More
Supply,Installation, testing and commissioning of MS Structure to support the DG exhaust pipe of suitable strngth to bear the load of the structure and the exhaust pipe, complete in every respect with one coat of primer and two coats of black enamel of good company

750

-

-

... More
VARIABLE REFRIGERANT FLOW (VRV/VRF) SYSTEM.

-

-

-

... More
The prices including all duties or local taxes on all equipments are to be quoted in the below mentioned form & shall include the supply, installation, testing & commissioning at site of all the equipments, ancillary materials as specified and all such items what so ever required to fulfill the intent and purpose as laid down in the specifications and / or drawings.

-

-

-

... More
Imported Variable Refrigerant Flow Air-conditioning System

-

-

-

... More
Supply, Installation, testing & commissioning of Variable Refrigerant Flow modular type airconditioning system Inverter Controlled with stepless modulation complete with indoor & outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping , full charge of refrigerant gas & oil, control cabling etc. as per detail given in specifications and having following items: (The prices to be given in Indian rupees on Full Import duty basis ) Refrigerant to be used shall be - R - 410 A.

-

-

-

... More
Supply, Installation, Testing and Commissioning of Modular type Outdoor unit equipped with highly efficient scroll compressors with all inverter type compressors special heat exchanger, low noise condenser fan , auto check function for connection error, auto address setting with double coat MS base frame (as per reccomendation from manufacturar) with sandwitch type vibration isolator rubber pads and capacity as mentioned below. Price shall be inclusive of first fill of regregerant , Lifting & placing of outdoor units at the locations as per drawing Makes: Daikin / Trane / OGeneral / Mitshubishi Electric.

-

-

-

... More
26 HP Heat Pump Type (Cooling & Heating )

3

-

-

... More
Supply, Installation, Testing and Commissioning of Indoor units WITH self diagnostic type remote controllers Corded Type address setting and capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain pump, drain water lift-up mechanism insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings of Makes: Daikin/Trane/OGeneral/Mitshubishi Electric.

-

-

-

... More
Ceiling Mounted Cassette Units:

-

-

-

... More
Ceiling Mounted Cassette Unit : 3.18 TR / 1130 CFM

11

-

-

... More
Ceiling Mounted Cassette Unit : 3.98 TR / 1165 CFM

6

-

-

... More
Ceiling Mounted Duct Type Units:

-

-

-

... More
Ceiling Mounted Concealed Unit : 6.36 TR / 2295 CFM

2

-

-

... More
Supply,Installation,Testing and Commissioning of Main Central Remote controller system with LCD panel suitable for above indoor units to operate, monitor, on/off, temperature setting etc. of Make Daikin/Trane/OGeneral/Mitshubishi Electric

1

-

-

... More
Heat Reclaim Ventilation(HRV) ( Fresh air Supply)

-

-

-

... More
To design & supply Heat Reclaim Ventilation (HRV) high static pressur,nighttime free cooling opration,contributes to energy conservation and more comfortable space. Makes: Daikin/Trane/OGeneral/Mitshubishi Electric

-

-

-

... More
HRV (heat reclaim ventilation) 375 cfm / 650CMH

2

-

-

... More
Refrigerant Piping

-

-

-

... More
Supply & Laying of interconnecting copper refrigerant pipe work with Y joints duly insulated with tubular elastomeric nitrile rubber insulation of thickness as specified, between indoor & outdoor units as per specifications. All piping inside the room shall be properly supported on galvenised perforated trays and all external piping shall run in galvenised covered perforated tray. MAKE: Copper Pipe -Madev / Maxflow/ Rajco. Insulation - Armaflex / Kflex / Aflex.

-

-

-

... More
41.3 mm O.D. (insulation - 19 mm thick)

150

-

-

... More
34.9 mm O.D. (insulation - 19 mm thick)

50

-

-

... More
28.6 mm O.D. (insulation – 19 mm thick)

90

-

-

... More
22.2 mm O.D. (insulation – 19 mm thick)

40

-

-

... More
19.1 mm O.D. (insulation – 19 mm thick)

200

-

-

... More
15.9 mm O.D. (insulation – 19 mm thick)

200

-

-

... More
12.7mm O.D. (insulation – 13 mm thick)

50

-

-

... More
9.5 mm O.D. (insulation – 13 mm thick)

200

-

-

... More
Supply, installation, and testing of site Fabricated Hard pvc pipes including necessary supports , nut bolts, gasket, etc. complete as per specifications in accordance with the approved shop drawings.

-

-

-

... More
6"dia pvc pipe

30

-

-

... More
8"dia pvc pipe

60

-

-

... More
10"dia pvc pipe

100

-

-

... More
Drain Piping

-

-

-

... More
roviding and fixing of cPVC drain water piping complete with fittings, support with MS hanger as per specification and insulated with 6/9 mm thick closed cell elastomeric nitrile rubber insulation.

-

-

-

... More
40 mm dia O.D with 9mm thick insulation

40

-

-

... More
32 mm dia O.D with 9mm thick insulation

50

-

-

... More
25 mm dia O.D with 6mm thick insulation

120

-

-

... More
Rectangular / Square Ducting ( Site fabrication )

-

-

-

... More
Supply, fabrication, installation, testing and commissioning of G.S.S.sheet metal ducting & as per ISI specifications & tender drawings. The price shall include with supports such as full threaded rod & GI slotted channel including nut bolt fastner or MS angle & MS rod including nut bolt fastner , sealent (neoprene gasket), access door etc.

-

-

-

... More
24 G (0.63 mm)

100

-

-

... More
22 G (0.80 mm)

50

-

-

... More
Supply, installation, testing & commissioning of Powder coated Aluminium extruded grilles with Al volume control damper for supply air normal flow, 15° deflection one way as per specification & the sizes will be as per tender drawing.

2

-

-

... More
Supply, installation, testing & commissioning of Powder coated Aluminium extruded grilles for return air normal flow, 15° deflection one way as per specification & the sizes will be as per tender drawing of make Systemair / Mapro /Trox / Metal Joint.

4

-

-

... More
Supply, installation, testing and balancing of powder coated /Anodised extruded aluminium construction outlet air louvers with bird screen of size upto 1.5 sqft area .

6

-

-

... More
Supplying, installing, and testing of GI volume control damper within ducts to be provided with levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system, Frame of the VCD shall be constructed from 18 gauge sheet & blades shall be constructed from 20 gauge sheet .

2

-

-

... More
Supplying, installing, and testing of GI volume control damper for round PVC pipe to be provided with levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system, Frame of the VCD shall be constructed from 18 gauge sheet & blades shall be constructed from 20 gauge sheet, galvanised steel spindle, self lubricating bronze bushes, blade. Linkage fully enclosed, stainless steel side seal gaskets, neoprene gaskets on blade tips complete with PVC knob operation and status indicator lockable in closed/open position, the linkage system shall be GI flats.

-

-

-

... More
Suitable for 6"dia pvc pipe

20

-

-

... More
TRANSMISSION CABLE

-

-

-

... More
Providing & fixing shielded control cum transmission cable of 2 core x 1.5 sqmm copper in suitable 20 mm dia heavy duty PVC conduits or wall chase or refrigerant piping between indoor units and outdoor units and indoor units and wired controllers.

400

-

-

... More
Flexible Duct Connection

-

-

-

... More
Supplying, fabricating, installing and testing of fire retardant nonporous double layer flexible connection constructed of fire resistant material For Evaporative cooling unit as per the drawings/specifications.

5

-

-

... More
Duct insulation

-

-

-

... More
Supplying and fixing of External Thermal duct insulation with 2 layer protective coating over closed cell Nitrile rubber (Class “O”) insulation on ducting after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation. All air ducts shall be coated with STARBOND 30-36 / FOSTER 30-36 in conjunction with 5 mil woven fiber glasscloth finally finished with 2 layers of STARBOND 30-36 to provide complete seal against air and moisture complete as per specifications and as required.

-

-

-

... More
Insulation material for Duct shall be anti-microbial closed cell Elastomeric Nitrile Rubber. Thermal conductivity of the insulation material shall not exceed 0.0362 W/moK or 0.208 BTU / (Hr-ft2-oF/inch) at an average temperature of 20oC. Density of the nitrile rubber shall be 40-60 Kg/m3. The product shall have temperature range of –40 oC to 105oC. The insulation material shall be fire rated for Class 0 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 perm inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ=7000: Water vapour diffusion resistance). Thermal conductivity of the material shall not be affected by ageing, as per DIN 52616, The smoke density of the material as per AS-1530.3 shall not exceed 1.The material shall be antimicrobial as per ISO 22196, C1338 and ASTM G21-96. There shall be no growth of fungus and mold. Insulation. Protective coating over insulation.

-

-

-

... More
19mm thickness insulation with protective coating

100

-

-

... More
Duct Acoustic lining

-

-

-

... More
Supply, installation testing and commissioning of duct acoustic insulation inside the Duct with Engineered Nitrile Rubber open cell foam with Density 140 - 180 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test or 10,000 fpm air velocity as per ASTM C 1071-05 to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents. Makes:Armacell/K-flex/A-flex

-

-

-

... More
10 mm thick acoustic lining

30

-

-

... More
Making hole in stone masonary/ RCC with core cutter for accomodating refrigerant pipe/ drain pipe for indoor m/c of VRV / VRF AC.

-

-

-

... More
50mm to 150mm

40

-

-

... More
Making the wall/window opening for grills and suitable for duct,repairing,plaster as per site requirement complete in all respect as per instruction of Engineer in Charge & making good same of required size as per drawing.

10

-

-

... More
Supply, Fabricating & installing following sizes of GI cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders, fastners, supports etc. as required.

-

-

-

... More
100mm x 50mm x 1.6mm

100

-

-

... More
300mm x 50mm x 1.6mm

50

-

-

... More
SITC of 2.0 mm thick (both base & cover) GI sheet raceway for copper piping from outdoor unit to shaft, The raceway shall be fixed on the floor with the help of suitable size galvanized MS angle support at 8" distance as approved from engineer incharge of size 250mm x 100mm.

100

-

-

... More
FIRE ALARM

-

-

-

... More
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit along with accessories in surface / recessed using saddles, clamps, fastener pvc bushes, check nuts, as required including cutting the wall and making good the same as required of Gr 1.

-

-

-

950

-

-

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required of Gr 1.

-

-

-

... More
2 x 1.5 sq.mm

950

-

-

... More
Supply , installation testing and commisioning of folowing modules suitable for Addressable fire Alarm Control panel taken.

-

-

-

... More
Monitor module for monitoring of flow switches of hydrent / sprinklers

4

-

-

... More
Control relay modules for tripping of AHU / pressurise fans and ventilators

4

-

-

... More
Control modules for floor wise activation of hooters

6

-

-

... More
Supply, Installation, Testing and Commissioning of intelligent Addressable MULTI CRITERIA optical and thermal DETECTOR including mounting base with LED etc. complete as required with two inbuilt Isolators or isolator base as per NFPA 72 Style 7 Wiring for maintaining operational availability of all elements in the loop, even in the event of a short circuit & Drift Compensation feature . High resistance to electromagnetic effects shall be UL/VDS/LPCB.

40

-

-

... More
Supply, Installation, Testing and Commissioning of Addessable Manual Break Glass/ flap Unit (Double action) with two inbuilt isolator or isolator module as per the NFPA Style 7 wiring with flexible network structures & necessary fixing arrangements with key complete as required shall be UL/VDS/LPCB (following EN54 Standard Approval).

11

-

-

... More
SITC of Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept / reset buttons for alarm address of any sensor / field device. The Repeater Panel shall only provide field device address with room number. Analogue Output is not required. The Panel shall be connected to the Fire Alarm Panel.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Stand alone Loop Powered Addressable sounder with 5 different programmable tone the sound pressure not less than 90 DB, it should be programmed from the panel shall be UL/VDS/LPCB . (In case of separately powered sounders, cost of the supervised power supply for each hooter with power cable shall be inclusive the cost of sounders itself and shall not be paid separately and power of sounders shall be fed from main Fire Alarm Panel only)

6

-

-

... More
Supplying, Installing, Testing and Commissioning of speaker for PA system.

-

-

-

... More
6-8 Watts ceiling mounted speakers

12

-

-

... More
10 Watts wall mounted speakers

4

-

-

... More
Supply, laying and commissioning of PVC insulated and PVC sheathed , 2 core shielded flexible copper wire of size 1.5mm, in existing Surface /recessed conduits ,Cable race ways, Trenches including cost of excavation and refilling, existing Pipes etc using all saddles, clamps, fasteners glands, lugs.

200

-

-

... More
Supply, Installation, Testing and Commissioning of Microprocessor based inteligent, Analogue addressable, modular, expandable networkable, 1 loops Panel (expandable upto 2 loops) with each loop capacity of 150 detectors per loop with total of 250 detectors & devices with Loop length up to 1.6 KM. Fire alarm control panel with touch screen LCD display / 320 character graphics LCD display, keypad, multiple access levels, 1000 event history logs in the non volatile memory (EEPROM). The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. The panel shall be compatible for integration 12 zones Voice evacuation system and shall be complete with all accessories required as per specifications. The panel shall be UL/VDS/LPCB approved.

1

-

-

... More
Supply , installation testing and commisioning of 6 ZONE Digital Voice Command Center with FACP, it shall contain all equipment required for all audio control, signaling and supervisory functions. This shall include speaker zone indication and control, digital voice units, microphone etc. The Digital Voice Command Center shall have digital voice call station suitable for 6 zone, digital voice controller & router suitable for 6 zone, 1no 480 watt amplifier & digital amplifier capable for 480 watt load etc. as required.

1

-

-

... More
Providing and fixing 4Kg Halotron™ I (Clean Agent) Type Fire Extinguisher. pressurized with Argon gas at 15 bar. Design, construction and testing as per IS 15683 with Fire rating 1A 13B, Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories. and wall suspension brackets as per approved make.

10

-

-

... More
P & F of LED exit signage of Box size as approved by engineer incharge of approved Make.

16

-

-

... More
Supplying and installing fire bucket stand including sheet metal (16 gauge) shade, platform and associated civil works each stand should have four nos fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters "Fire" in black and gold & one no fire man's axe at approved location as per approved make.

2

-

-

... More
Supply & Fixing ISI marked ( IS : 15683 ) Poratable Fire Exitnguisher,Trolley mounted Mech. Foam type capacity 09 ltrs with gun‐metal cap and nozzle and complete respects in all respects including initial fill and wall suspension.

1

-

-

... More
Supply & Fixing ISI marked ( IS : 15683 ) Portable fire Extinguisher, Carbon‐dioxide type flat base including valve, discharge hose of not less than 10 mm dia. min. 600 mm long & complete in all respects including initial fill with C02 gas confirming to IS:307‐1966 filled to a filling ratio of not more than 0.667and wall suspension bracket. Capacity 4.5 Kg.

6

-

-

... More
Supply & Fixing ISI marked ( IS : 15683 ) Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of following capacity.

-

-

-

12

-

-

... More
Supply & Fixing of ISI marked ( IS : 15683 ) Fire Extinguisher, Trolley mounted, CO2 (gas pressure) type capacity 22.5 Kg. with gun‐metal cap. And nozzle and complete in all respects including initial fill and wall suspension bracket.Capacity 22.5 Kg.

1

-

-

... More
SANITARY FIXTURES AND C.P. FITTINGS - SUPPLY AND INSTALLATION

-

-

-

... More
Supply, installation, testing and comissioning of wall hung European WC, seat & cover, chair brackets, concealed flushing cistern, health faucet, angle stop cocks - if required, 2way bib cock complete with all necessary hardware, nipples, reducers etc to complete work by contractor. P.V.C. WC connector (straight or bend type) with rubber lip ring to be included in the item. Health facuet to be provided with flexible pipe (standard company product as per model no of faucet) and mounting clamp. Painting 2 coats with base coat primer to be done for chair bracket.

24

-

-

... More
Supply, installation, testing and comissioning of counter top / semi recessed / Wall mounted hand wash basin, 32mm CP waste coupling with or without pop out, 32 mm C.P. bottle trap with cleaning eye with extension piece and wall flange, angle stop cocks, CP pillar cock / basin mixer with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure complete with all necessary hardware CI bracket supports / Rack bolts. nipples, reducers etc to complete work by contractor. Counter with necessary holes shall be installed by civil / interior contractor. Sealing of gap between basin and counter shall be done by plumbing contractor with epoxy / white cement as directed by architects - interior designer.

20

-

-

... More
Supply, installation, testing and comissioning of under counter SS sink, single bowl, till 900 length and 450 mm depth, 40mm CP waste coupling with or without pop out, 40 mm C.P. bottle trap with cleaning eye with extension piece and wall flange, angle stop cocks, CP pillar cock / basin mixer with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure complete with all necessary hardware, nipples, reducers etc to complete work by contractor. Counter with necessary holes shall be installed by civil / interior contractor. Sealing of gap between sink and counter shall be done by plumbing contractor with epoxy / white cement as directed by architects - interior designer.

16

-

-

... More
Supply, installation, testing and comissioning of urinals, concealed type wall hanger or special bracket in wall and hinged type C.P. dome gratings, angle stop cocks, auto flush, 32mm CP waste coupling, 32 mm C.P. bottle trap with cleaning eye with extension piece and wall flange - if required as per urinal model, C.P. flush pipes from manual / auto flush, spreaders, full bore inlet caps as necessary made to measure, with separate auto flushing system with battery complete with all necessary hardware, nipples, reducers etc to complete work by contractor. Painting 2 coats with base coat primer to be done for chair bracket.

25

-

-

... More
Supply, installation, testing and comissioning screw down Angle stop cocks with wall flange of heavy quality with all accessories.

60

-

-

... More
Supply, Receiving, checking, storing & fixing screw down Bib cocks with wall flange of heavy quality with all accessories.

20

-

-

... More
Drain connection to kitchen equipment (other than sinks) including necessary UPVC pipe and connections to drain (40/50 mm)

10

-

-

... More
Supply, Receiving, checking, storing & fixing of 2 Nos. 600mm long wall mounted grab bar, Raised toilet soft close seat cover for handicap toilet complete as recommended

25

-

-

... More
WATER SUPPLY

-

-

-

... More
Providing, fixing, jointing and testing, heavy quality cast bronze / brass ball valves of approved make, including flanges / unions, nuts, bolts, washers, etc. complete, as approved by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size:

-

-

-

1

-

-

1

-

-

1

-

-

4

-

-

... More
20 mm

4

-

-

... More
15 mm

4

-

-

... More
Providing, fixing, jointing and testing, heavy quality CI slim seal type PN10 butterfly valve with rubber gasket, flanges / unions, nuts, bolts, washers, etc. complete, as approved by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size:

-

-

-

2

-

-

2

-

-

... More
Providing, fixing, jointing and testing, heavy quality gun metal or brass non return valve confirming to IS 778, with screwed / flanged ends, 20 kg/m2 on water supply lines of the following nominal bore (NB) size:

-

-

-

2

-

-

2

-

-

2

-

-

2

-

-

... More
Providing, fixing and testing, heavy quality Pressure reducing valves of approved make as approved,including flanges / unions, nuts, bolts, washers, Pressure guages, etc. complete by the Architect and Engineer-in-charge for water supply lines of the following nominal bore (NB) size: The upstream water pressure may be upto 10 kg/cm2g max. and downstream pressure min. 1 kg/cm2g.

-

-

-

4

-

-

4

-

-

2

-

-

2

-

-

2

-

-

... More
Providing, fixing, jointing and testing Brass heavy duty foot valve screwed / flanged, with the required accessories, of approved make, as recommended, complete, of the following nominal bore (NB) size:

-

-

-

... More
100 mm

4

-

-

4

-

-

2

-

-

2

-

-

... More
Earth Work in Excavation of required width for water supply pipes including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil and then backfilling the soil as required in layer not exceeding 20 cms in depth including consolidating each deposited layers by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50 m. for all kinds of soil.

-

-

-

... More
Pipe up to 80 mm dia (Assumed)

20

-

-

... More
Pipes, exceeding 80 mm dia but not exceeding 150 mm dia.

10

-

-

... More
Providing and filling sand of grading zone V or coarser grade alround the water supply pipes and about 300 mm above the pipe surface in the external work.

-

-

-

... More
Pipe up to 80 mm dia

20

-

-

... More
Pipes, exceeding 80 mm dia but not exceeding 150 mm dia.

10

-

-

... More
Providing and fixing C-PVC pipe as per ASTM D 1785 upto 50mm dia use SDR 11 & larger than 50 mm use sch 80 piping system joined by solvent cement with necessary fittings for domestic and flushing water supply piping for all the water supply of the following nominal bore (NB) size:

-

-

-

... More
G.I. Heavy class pipe sleeves of specified diameter corresponding to the pipe size shall be provided wherever the pipes are crossing the fire rated walls/floors slab and sealing the sleeves with glasswool in between and fire sealant compound on either end, all as per E-I-C's requirement

-

-

-

... More
Galvanised clamps and brackets, legend boards shall be included in the price

-

-

-

... More
Cutting and chasing in wall and floors with diamond cutter for CPVC pipes and fittings & making good the same by using 1:1 cement mortar over the wire mesh with the tint of GERU etc to be included in the rates.

-

-

-

... More
For Internal toilet

-

-

-

50

-

-

100

-

-

25

-

-

150

-

-

... More
External pipes - in shafts / underground ring / terrace rings/Pump Room

-

-

-

100

-

-

50

-

-

50

-

-

100

-

-

52

-

-

50

-

-

... More
Providing and fixing in position of approved quality G.M. float valve with copper ball float and brass rods of required length suitable for test pressure of 15Kg/sqcm of the following sizes:

-

-

-

2

-

-

2

-

-

... More
Providing and fixing water meter station with direct reading dial in KL with all integral parts of gun metal or brass with neccesary fitting such as threaded pieces, unions pressure guage and isolation cock, flanges piece for future removal, flanges/unions complete with all necessary testing charges and obtaining test cetificates from municipal authorities.

-

-

-

... More
32 mm

1

-

-

... More
Constructing chamber in brick masonry chamber for valve / water meters, in 230 mm. thick brick masonry, in CM 1:5, constructed over a bed of 1:4:8 CC 150 mm. thick, plastering inside, outside and all exposed surfaces with 1:3 CM, 15 mm thick, including providing and fixing CI frame and cover weighing not less than 12.5 Kg, including painting of cover with black bitumastic paint etc. complete. Size of chamber is

-

-

-

... More
Size 1200 x 750 mm - upto 1000mm depth

2

-

-

... More
INTERNAL DRAINAGE AND RAIN WATER

-

-

-

... More
Providing, fixing, jointing and testing heavy duty, UPVC SWR pipes, - type B, open, low density, to wall, ceiling and floor, approved quality, complete, for soil and waste water drain including jointing with rubbering / solvent / solution and airtight joints, with necessary special couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage, double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor etc. complete of the following nominal bore (NB) size:(where ever necessary CP shall be provided)

-

-

-

... More
G.I. Heavy class pipe sleeves of specified diameter corresponding to the pipe size shall be provided wherever the pipes are crossing the fire rated walls/floors slab and sealing the sleeves with glasswool in between and fire sealant compound on either end, all as per E-I-C's requirement

-

-

-

... More
Galvanised clamps and brackets, legend boards shall be included in the price

-

-

-

... More
Cutting and chasing in wall and floors with diamond cutter for CPVC pipes and fittings & making good the same by using 1:1 cement mortar over the wire mesh with the tint of GERU etc to be included in the rates.

-

-

-

... More
Vertical downtakes of soil, waste, antisyphonage & basement ceiling level drainage - Till GT

-

-

-

... More
110 mm

50

-

-

50

-

-

... More
Providing, fixing, jointing and testing heavy duty, UPVC upto 50mm dia use SCH-80 & larger than 50 mm use Type-B piping system, open, low density, to wall, ceiling and floor, approved quality, complete, for soil and waste water drain including jointing with rubbering / solvent / solution and airtight joints, with necessary special couplers, elbow, equal tees, tail piece, adapter (both male and female), reducer (single stage, double stage and triple stage), end cap, fabricated bend, etc., and lubricant or jointing material, including testing, cutting, making good the wall, ceiling and floor etc. complete of the following nominal bore (NB) size:(where ever necessary CP shall be provided)

-

-

-

... More
G.I. Heavy class pipe sleeves of specified diameter corresponding to the pipe size shall be provided wherever the pipes are crossing the fire rated walls/floors slab and sealing the sleeves with glasswool in between and fire sealant compound on either end, all as per E-I-C's requirement

-

-

-

... More
Galvanised clamps and brackets, legend boards shall be included in the price

-

-

-

... More
Cutting and chasing in wall and floors with diamond cutter for CPVC/UPVC pipes and fittings & making good the same by using 1:1 cement mortar over the wire mesh with the tint of GERU etc to be included in the rates.

-

-

-

... More
Internal toilet drainage soil, waste pipe & Rainwater Downtakes

-

-

-

... More
110 mm

175

-

-

125

-

-

... More
Providing, fixing, jointing and testing PVC P- traps / Floor Trap / Multi Trap of self cleansing design with water seal not less than 80 mm., with or without vent, jointing with proper solvent, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be 'P' type, of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry. S.S. grating, Mosquito proof S.S. strainer and Adopter to be provided.

-

-

-

... More
100 x 100 mm OD inlet / outlet

4

-

-

... More
100 x 80 mm OD inlet / outlet

2

-

-

... More
Floor Trap/ Multi Floor Trap with S.S. grating and Mosquito proof S.S. strainer

65

-

-

... More
Providing, fixing, jointing and testing Nahni Trap of self cleansing design with water seal not less than 25 mm., with or without vent, jointing with proper solvent, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry. S.S. grating, Mosquito proof S.S. strainer and Adopter to be provided.

-

-

-

... More
Nahni Trap with S.S. grating and Mosquito proof S.S. strainer

25

-

-

... More
Providing and fixing, Cast iron cowl, on C.I ventilating pipes and verticals for rain water Pipes at top level / terrace level, as specified and required, etc. complete.

20

-

-

... More
Providing and fixing, PVC cowl, on PVC ventilating pipes and verticals for soil, waste & rain water Pipes at top level / terrace level, as specified and required, etc. complete.

12

-

-

... More
EXTERNAL SEWERAGE & STORM WATER DRAINAGE

-

-

-

... More
Providing and laying non pressure NP3 class (medium duty) R.C.C. pipes with collar joints with stiff mixture cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.

-

-

-

... More
150 mm dia R.C.C pipe

25

-

-

... More
Providing , Fixing, testing and commissioning and laying UPVC Foamcore Class-SN-8 pipes, including testing of pipes and joints etc. complete with the necessary excavation, providing and laying PCC (1:4:8), laying, refilling, compaction, dewatering, curing, retesting and disposal of any excess earth/soil from the site. The pipes shall be of following nominal bore (NB) size:

-

-

-

... More
160 mm

25

-

-

... More
Constructing Rectangular inspection chamber / Manhole in brick masonry chamber for valve, in 230 mm. thick brick masonry, in CM 1:5, constructed over a bed of 1:4:8 CC 150 mm. thick, plastering inside, outside and all exposed surfaces with 1:3 CM, 15 mm thick, including providing and fixing CI heavy duty frame and cover weighing not less than 12.5 Kg, including C.I. heavy duty steps, painting of cover with black bitumastic paint etc. complete. Size of chamber is

-

-

-

... More
Size 900 x 900 mm - upto 1500mm depth

5

-

-

... More
Constructing Conical chamber 1350 dia. at bottom tapering upto 900mm from G.L./R.L. 600mm dia. at top inside 450mm brick masonry with cement mortar 1:5 as per ISI with 230mm th. 1:3:6 mix PC bedding, necessary benching and 20mm th. smooth cement 1:4 inside as directed C.I. steps, C.I. Frame & cover weighing not less then 12.5Kg. as necessary

-

-

-

... More
upto 2 mtr Depth

2

-

-

... More
Providing, fixing, jointing and testing salt glazed stoneware gully trap, class `A', of 100 mm. dia. inlet and 100 mm. outlet, including excavation in all soil types, bailing or pumping out water from trenches, shoring whenever necessary testing,refilling, in layers ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed, incl. embedding the trap in CC 1:2:4, construction of brick masonry chamber, internal clear size 300 mm. x 300 mm., in brick work 230 mm. thick, in CM 1:4, plastering inside, outside and all exposed surfaces with CM 1:3, 12 mm. thick, providing, fixing CI frame and cover 300 x 300 mm., weighing together not less than 12.5 Kg., painting of all CI items with 3 coats of approved bitumastic paint, etc. complete.

-

-

-

... More
160 x160mm Gully Trap with chamber

2

-

-

... More
Construction of 1950 x 1100mm size Grease Trap with 2 nos cover of 600 x 600 mm clear size in 230 mm thick brick masonry with cement mortar (1:5) as per ISI with 150 mm thick 1:3:6 P.C.C. bedding, necessary benching in concrete (M-15) and 20 mm thick smooth cement plaster (1:4) from inside, C.I. steps as necessary and rough cement plaster 20 mm thick in c.m. 1:4 outside, with 150 kg. Full size C.I. manhole cover and frame (Approved Make) including all excavation in all soil types, refilling sides in layers with selected earth ramming and consolidating, removing away surplus soil or dumping it on site as directed (Depth upto 1500 mm to invert). As per typical drawing

1

-

-

... More
450 x 450 mm clear inside dimensions

1

-

-

... More
Charges for connection to main drainage from the local authority as per the local rules and regulations, including excavation in all kind of soil (including hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material dumping it on site or carting away to lead of 100 meters as directed and making good the same complete as required. Liasioning fee is included in the rates.

1

-

-

... More
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:

-

-

-

... More
5000 litres capacity

4

-

-

... More
Hoisting Charges for each floor :

-

-

-

... More
For items 2.26.5 to 2.26.8

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.