If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,56,540Document Cost
₹ 1,180Tender Fee
₹ 1,500
Summary
Electrical Distribution Lighting And Fans Works Of Campus And Court Building At Ajmer
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RSRDC_433697_1Bid Award Id
ViewTender No
RSRDCC NIT 358/2024-25 DATED 29.11.2024 Sl No. 2Tender Authority
Rajasthan State Road Development And Construction Corporation Limited ViewPurchaser Address
-Website
http://http://roads.rajasthan.gov.in/content/raj/roads/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
VARIOUS ACT CIRCULARS NOTIFICATION AND ORDERS
GENERAL TERMS AND CONDITIONS ALONGWITH DLP TERMS AND CONDITIONS
ANNEXURE A,B,C,D AND RTPP ACT 2012, ANNEXURE C
ELIGIBILITY OF CRITERIA OF BIDDER FOR QUALIFYING IN TECHNICAL BID
BOQ Items
... More
3 Mtr.
12
4800
57600
... More
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
-
-
-
... More
Electrolytic grade Aluminium bus bar
60
420
25200
... More
SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Group-1.
-
-
-
... More
Digital type
6
1100
6600
... More
SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Group-1.
-
-
-
... More
Digital type
-
-
-
... More
Below 500 A
6
1100
6600
... More
SF of Current Transformer , with all necessary support in existing panel including connection etc. as required. Group-1 .
-
-
-
... More
from 200 / 5 to 400/5 Ratio , 10 VA , class 1 accuracy
18
323
5814
... More
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. Group-1.
-
-
-
... More
Red/yellow/Green colour
18
150
2700
... More
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required. Group-1.
-
-
-
... More
With Thermal Magnetic release
-
-
-
... More
up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
6
6341
38046
... More
up to 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
6
7800
46800
... More
160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
6
8186
49116
... More
200 Amp , 25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
6
16210
97260
... More
P&F on load change over switch, front handle operated, four pole 415 V conforming to IS:13947 P-III including connections , testing etc. as required. Group-2 in the following rating:
-
-
-
... More
Open execution type
-
-
-
... More
250 A
1
12558
12558
... More
P/Laying P.V.C. / XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required. Group-1 of size.
-
-
-
... More
6.0 Sq.mm
-
-
-
... More
4 core
500
146
73000
... More
95.0 Sq.mm
-
-
-
... More
3.5 core
600
523
313800
... More
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. Group-1 of size.
-
-
-
... More
4 x 10.0 sq.mm
60
63
3780
... More
3.5 x 95.0 sq.mm
40
286
11440
... More
Part (B) Non BSR Items
-
-
-
... More
As per Electrical BSR 2022
-
-
-
... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
-
-
-
... More
(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
-
-
-
... More
(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
-
-
-
... More
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
-
-
-
... More
(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
-
-
-
... More
(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
-
-
-
... More
(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
-
-
-
... More
(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
-
-
-
... More
(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
20
5975
119500
... More
Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current 750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
... More
Minimum lumen output 4000 lm Post top Luminarie
12
6575
78900
... More
Providing & Fixing of IK10 IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . driver current 750mA . Fixture must be in compliance with BIS Standards and Trade mak Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
... More
Minimum lumen output 800 lm Step light
30
4886
146580
... More
Providing & Fixing of IK10 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 90 Lumen/W. COB LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. driver current 750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
... More
Minimum lumen output 2150 lm Up-Down Luminary
20
9519
190380
... More
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
... More
1200 mm Sweep BEE 1 Star rated (service value =4.0 to 4.5 )
1297
1890
2451330
... More
Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be = 75 dB, power consumption = 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
... More
Wall mounting type with Adjustable Vertical Angle
115
4969
571435
... More
Supply , Installation, Testing and Comissioning of IS:1475 marked self contained drinking water cooler with hermetically sealed compressor,non CFC refrigerent suitable for operation on 230V/1pH/50Hz AC supply,Full stainless steel (SS304)body (0.8 mm thick) and tank (0.5 mm thick) , stainless steel water tray,minimum two nos Brass Chrome plated faucets and suitable drainage system complete in all respect with required height MS fabricated and Painted Angle iron frame ( Cost of frame to be paid Extra )complete in all respect of the following capacity. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
... More
cooling capacity 150 Ltr./Hr. and storage capacity 150 Ltrs
12
75878
910536
... More
As per Market Rates / Already Approved
-
-
-
... More
SITC of RO water system with Filtration stage = Particulate filter-Membrane life enhancer filter - sediment filter - Pre carbon filter -RO Membrane filter - Post carbon filter,Input power Rating - 230 V AC , 50 HZ, Percentage of Rejection TDS - 90% or better having following Features (a) Double purification by RO with ESS or latest technology with TDS indicator (b).Spin welded RO Membrane Housing to prevent tempering (c). Push fit components for leak proof performance (d). Fully automatic operation with auto start and auto off (e). SS construction for corrosion free lifespan (f). Equally suitable for water from all bore wells,,overhead storage tanks,water tankers and even municipal taps (g) RO Membrane Flushing - Auto Flush @ Every Start , Every Stop and every One Hour of working for one minute. complete in all respect with following capacity. Approved Make:Eureka forbes, Kent, AU Smith, Ion Exchange, pentair.
-
-
-
... More
Purification capacity- 50 LPH,Duty Cycle 270-500 liters/day,
12
56600
679200
... More
SITC Of Low Height Ceiling Fan with sweep (dia of blade) 400 +/- 5mm sweep, Air delivery 75CMM , Rated Power 95watt, supplyvoltage 230 v 50Hz single phase, rated speed 1750 RPM, power factor -0.90 , size- 580x580+/- 5 mm make- Halonix, havells, Crompton
70
7500
525000
... More
Supply, installation and fixing of Ornamental Decorative Street Lighting Pole having provision to fix decorative Double arm bracket. Installation of same with foundation bolts of suitable size to grout it into specially designed RCC Foundation as per our provided drawing. Cost of Foundation is included in this rate only.The decorative bracket shall be fixed on the top of the Pole as per detail given below: Pole: The Pole part is of height 5.5mtrs & approx weight 90 kgs. The pole has cast iron bottom base of height 210mm on base plate 300*300*12mm. The base plate is welded to Grooved ms column of OD 135mm of length 1.5mtr. Middle section is OD82mm Grooved column of 4mtr Length and having Casting Rings on the joint and in the middle. The bottom section has inbuilt junction box that is suitable for wiring and fixing MCB. Overall Weight of Pole – 90 kgs approx. The design of each part is clearly shown in drawing.
Brackets: The architectural custom design Double Side combo bracket as shown in the drawing are of as per mentioned dimensions Width- 1800mm; Ht- 1500mm. The bracket is provided with decorative Cast Iron and Aluminium embellishments on both sides as well as on the top for aesthetics. Overall Weight of bracket will be 30 kgs approx. Lamp: 2NOS. 60W or above Led fitting in hanging type design made of Aluminium housing in size 420mm x 350mm with Frosted diffuser duly silicon filled, UV resistant powder coated and lacquer coated in antique finish. Highly efficient electronic external POTTED BIS registered driver, 10 KV SPD, High voltage protection power Led in White or Warm-White of make Osram/PWM/Lutron mounted in MCPCB with heat dissipater arrangement. Duly wired up and complete as required on site.
Finish: All the Parts of the Pole & bracket are finished as per the following procedure to procure the supreme quality of finishing. All the items are painted in 4 layer coating in which first layer is done by Epoxy primer(to prevent corrosion), second layer epoxy base colour then third layer with Polyurethane Metallic paint (any shade as per required) and final layer of PU lacquer to prevent from UV Rays of Make:- Klite/ Twinkle/ Lumen /Luster/Crompton
18
78000
1404000