Rajasthan State Road Development And Construction Corporation Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan State Road Development And Construction Corporation Limited - RSRDC Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Jan 2025
Closing Date13 Jan 2025
Tender Amount₹ 6,11,71,000 
Notes
Download

Costs

  • EMD

    ₹ 12,23,420
  • Document Cost

    ₹ 5,900
  • Tender Fee

    ₹ 2,500

Summary

Sitc Of Air Conditioning Work For Construction Of Court Complex And Advocate Chambers At District Head Quarters, Sri Ganganagar.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing & Fixing of fixed speed multi compressors modular Air Cooled scroll type chillers of Nominal cooling capacity 36 TR to 40 TR( Total Capacity of module should not less then 395 TR and No. of Chillers should be Minimum 11 Nos.) complete with fixed speed multi compressors (Min. 2 per chiller) fully hermetic scroll compressors, 2 fan motor, starter, air-cooled condenser with blue fins, evaporator of Shell & Tube, vibration isolators, inbuilt accumulator, environment friendly refrigerant R-410A, first charge of refrigerant and oil, wiring, all accessories as per specifications, automatic and safety controls, microprocessor control panel, all mounted on steel frame, all accessories as per specifications and any other item required to make the system complete. Preferred Make:- Daikin/ York/Trane/ Carrier/Dunham Bush/ Blue Star/ Voltas/LG

-

-

-

... More
Chiller type : Modular air cooled fixed speed scroll, Capacity - 36 to 40 TR Minimum chillers quantity sholud be 11 nos.

-

-

-

... More
These Modular Unit mandatorily should have Master and Slave Arrangments to run in single circuit of 11 Units as one

-

-

-

... More
Machine Should be Modular Only

-

-

-

... More
Maximum Chillers should not be above 16 nos. Including Standby Chiller in One Circuit.

-

-

-

... More
Modular Design to allow connection of multiple machines to make them behave as one unit. And the overall set to continue working in case of break down of one module.

-

-

-

... More
All the compressors in the system should be running on equal hours.

-

-

-

... More
Machine should be Modular type with Emergency Backup operation for Continuous Operation When one circuit fails , other circuit can continue to operate Balanced Compressor Operation

-

-

-

... More
Real-time monitor, adjust and balance the running time of each module and compressor in the system intelligently, which effectively extend the service life of the unit and reduce the frequency of maintenance.

-

-

-

... More
Evaporator type - High efficiency shell and tube type/BPHE

-

-

-

... More
Condenser type - High Efficiency Copper Tubes with Aluminium Blue Coated Fins

-

-

-

... More
Refrigerant - R410A, Min. No. of compressors per chiller - 2 nos. ( No Glide Refrigerant shall be acceptable )

-

-

-

... More
Power Supply: 380-415V/3P~/50Hz

-

-

-

... More
Water Outlet temperature: 7 Deg C

-

-

-

... More
Water Inlet temperature: 12 Deg C

-

-

-

... More
Evaporator Fouling Factor - 0.0001 ( FPS )

-

-

-

... More
Condenser Design Temperature - 35 Deg C

-

-

-

... More
There will not be any other Primary Chilled Water Pump for the system apart from mentioned below quantity to run the chiller operations smoothly.

-

-

-

... More
Minimum COP of complete chiller : Should not be below 3.0 at 100% load @ 35 Deg C. (Note- COP of the chiller should be inclusive of all the auxillary power consumption like fan power etc )

-

-

-

... More
All the Controller Should have open protocol which should be not be locked out after warranty or during warranty period

-

-

-

... More
Note- All the passwords related to Operation, Service or any other setting in the chiller which required password by OEM. Has to be handed over to purchaser at the time of successful commissioning of equipment.

-

-

-

... More
Please submit the Catalogue mentioning Modular Design with Maximum 16 Nos Chillers in one circuit at the time of TENDER SUBMISSION. - No Deviation Accepted. In case of no catalogue submission then the tender will be rejected.

-

-

-

... More
AIRCOOLED 36 ~ 40 TR CHILLER- (SCROLL COMPRESSOR MODULAR TYPE )

11

1195000

13145000

... More
Providing & Fixing of Flow Switches for Chilling Machines including socket welded etc as required.

11

5200

57200

... More
Providing & Fixing of Remote Controller for Each Chiller Unit - Wired Type ( Wire for remote controller included ) Each Controller Shoule be able to fully operate on individual chiller of 36~40 TR Capacity unit.

11

42000

462000

... More
There Should be one Master controller to operate all the chillers in one circuit. a. Master Controller should be able to handle Master and Slave Arrangments. b. Should be able to operate, control and monitor each individual chiller in one circuit. Master Controller will be kept in control room. Each Master Controller should be able to handle minimum 16 nos of chiller in one cirucit.

1

85000

85000

... More
Any Required accessories for the operation of chiller controlling will be in chiller suppliers scope. Please include all the costs related to chiller operation. No additional accessories like Flow Meter, Electrical Device, Sofware & Hardware etc if requrired will be provided by Chiller Supplier.

-

-

-

... More
Providing & Fixing of End suction pumps complete with motor , base frame, vibration isolators and other accessories (except suction and discharge shut off valves, suction strainer, discharge check valves and drain piping which are covered under separate items.) Pumps shall have mechanical seal and Bronze/S.S. Impeller. The pump motor shall be suitable for 415 ± 10%, 50 cycles, 3 phase power supply, squirrel cage induction 2900 RPM TEFC, IE3 motor. (earthing, control wiring and main cable from electrical panel to unit with cable tray with necessary accessories, are covered under separate items) with vibration isolators. Pumps shall be complete as per specifications and shall have operating parameters as given below :

-

-

-

... More
Preferred Make : Grundfos/ DP/Xylem/Armstrong

-

-

-

... More
Primary Chilled Water Pumps

-

-

-

... More
Note - All pumps should be Facotry Fitted only.

-

-

-

... More
Flow rate : 510 USGPM

3

302425

907275

... More
Head : 15 M, RPM -1450

-

-

-

... More
(2 Working + 1 Standby for Each Circuit)

-

-

-

... More
Secondary Chilled Water Pumps

-

-

-

... More
Note - All pumps should be Facotry Fitted only.

-

-

-

... More
Flow rate : 510 USGPM

-

-

-

... More
Head : 25 M, RPM -1450

3

367000

1101000

... More
(2 Working + 1 Standby for Each Circuit)

-

-

-

... More
Providing & Fixing of variable speed pumping system comprising of following accessories and as per the specifications. The system shall be complete in all respects including electrical components suitable for pump motor. Each pump shall have variable frequency drive. Preferred Make : Grundfos/ DP/Xylem/KSB

-

-

-

... More
For Chilled Water Variable frequency drive (VFD) : 3 Nos. panel should be IP-54 rating & VFD should be IP-20 with IP 54 enclosure panel without bypass system VSPS shall be BMS compatible and interfacing amongst all components and compatibility of I/O signals shall be provided : 1 Set Variable Speed Pumping System as described above.

1

650000

650000

... More
Providing and fixing of double skin modular construction, draw through Ceiling Suspended (CS) Air Handling Units, each complete with DIDW Centrifugal fan forward curve blower, Squirrel cage,IE3, TEFC induction motor, cooling coils (Copper tubes and Aluminium fins), pre-filter (Washable Synthetic fibre of efficiency 90% down to 20 micron), Sandwich type drain pan of 20 gauge, SS - 304 inner sheet, 12 mm thick insulation and outer cover should be G. I. with S S drain socket 32mm dia, V belt drive and other accessories as per specifications (except water shut off valves, drain piping and pressure gauges which are covered under separate item). Motor shall be suitable for 415 ± 10% volts, 50 cycle, 3 Phase AC supply. The RPM of AHU should be less than 900 and blower discharge face velocity should not cross 10 FPS and all AHU should be single blower, make of blower is Nikotra/Kruger/ Greenheck . The details of AHU's are as indicated below:

-

-

-

... More
Preferred Make : Zeco/ Edgetech/ Systemair/ Revo/Flaktwood/Bryair/ Caryaire/ TRANE

-

-

-

... More
CFM Type SP mm RD Phase TR

-

-

-

... More
2000 CS 40 6 3 5.00

10

75000

750000

... More
2400 CS 40 6 3 6.00

23

112000

2576000

... More
3500 CS 40 6 3 8.75

6

135000

810000

... More
4000 CS 40 6 3 10.00

3

152000

456000

... More
Providing and fixing of PIC valves with modulating actuator suitable for Chilled water application complete with Electrical/Electronic actuator and required accessories for proper operation and control of valves of following sizes.

-

-

-

... More
Preferred Make : Danfoss/ Honeywell/ Siemens

-

-

-

10

10500

105000

23

23800

547400

9

42500

382500

... More
Providing and fixing of digital thermostats for various Air Handling Units to control PICV valve as per specifications.

42

6200

260400

... More
Preferred Make: Danfoss/ Honeywell/ Siemens

-

-

-

... More
Providing and fixing of Horizontal type ceiling suspended fan coil units complete with fan, 3 speed motor, copper chilled water coil, aluminium finses, SS-304 sandwith type condensate tray insulated 10 mm thick as required as per specification.

-

-

-

... More
Preferred Make : Zeco/ Edgetech/ Systemair/ Revo/ Flaktwood/Bryair / TRANE

-

-

-

... More
1200 CFM (3.0 TR)

6

28500

171000

... More
1000 CFM (2.5 TR)

3

27500

82500

... More
800 CFM (2.0 TR)

18

26500

477000

... More
600 CFM (1.5 TR)

57

23800

1356600

... More
400 CFM (1.0 TR)

40

19850

794000

... More
Ball Valves with Strainer (Preferred Make: Zoloto/Castle/Sant/Shri/NVR)

-

-

-

... More
25 mm dia

27

1840

49680

... More
20 mm dia

97

1500

145500

... More
Ball Valves without Strainer (Preferred Make: Zoloto/Castle/Sant/Shri/NVR)

-

-

-

... More
25 mm dia

27

1385

37395

... More
20 mm dia

97

1150

111550

... More
Providing and fixing of controls for fan coil units consisting of PIC valves along with required flare nuts, copper pipe connectors etc as required.

-

-

-

... More
Preferred Make : Danfoss/ Honeywell/Siemens

-

-

-

... More
Water Flow Rate 7.2 USGPM

6

10800

64800

... More
Water Flow Rate 6.0 USGPM

3

10800

32400

... More
Water Flow Rate 4.8 USGPM

18

10800

194400

... More
Water Flow Rate 3.6 USGPM

57

10800

615600

... More
Water Flow Rate 2.4 USGPM

40

10800

432000

... More
Providing & Fixing of digital thermostat with 3 speed fan control switch. (6 Amp. Light plug & supply will be provided by another agency of the building above false ceiling near trap door.)

-

-

-

... More
Preferred Make : Danfoss/ Honeywell/Siemens

124

6200

768800

... More
Providing & Fixing of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239.

-

-

-

... More
Preferred Make: Jindal Star/ Jindal Hisar/ TATA

-

-

-

... More
20 MM (19 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

560

650

364000

... More
25 MM (19 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

700

760

532000

... More
32 MM (19 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

980

910

891800

... More
40 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

470

1060

498200

... More
50 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

560

1380

772800

... More
65 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

700

1890

1323000

... More
80 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

330

2070

683100

... More
100 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

240

2850

684000

... More
125 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

100

3100

310000

... More
150 MM (19 mm +13 mm thick Insulation UV Cloth & 2 Layers of UV Paint)

50

3800

190000

... More
200 MM (19 mm +13 mm thick Insulation Aluminium Cladding with Vapour Barrier)

70

6790

475300

... More
250 MM (19 mm +13 mm thick Insulation Aluminium Cladding with Vapour Barrier)

100

7100

710000

... More
Providing and fixing in position the following Ball valves, flanges, Rubber Gasket, nut bolts, nipples etc as required with insulation.

-

-

-

... More
(Preferred Make: Advance/ Castle/ Keystone/ Honey well/ Sant/ leader/ Zoloto/Kartar/NVR)

-

-

-

20

2150

43000

46

3100

142600

... More
Providing and fixing in position the following Butterfly Valves PN16 SG Iron Disc, flanges, Rubber Gasket, nut bolts etc as required with insulation.

-

-

-

... More
(Preferred Make: Advance/ Castle/ Keystone/ Honey well/ Sant/ leader/ Zoloto/Kartar/NVR)

-

-

-

18

4400

79200

22

5800

127600

2

4850

9700

... More
100 mm

8

6250

50000

... More
125 mm

3

8510

25530

... More
150 mm

12

9780

117360

... More
Providing and fixing in position the following Balancing Valves PN 16, flanges, Rubber Gasket, nut bolts etc as required with insulation.

-

-

-

... More
(Preferred Make: Econosto/ Keystone/ Castle/ Sant/ Honeywell/ Leader/Kartar/NVR/LP)

-

-

-

... More
65 MM

11

12500

137500

... More
Providing and fixing in position the following Y-strainers PN 16, flanges, Rubber Gasket, nut bolts etc as required with insulation.

-

-

-

... More
(Preferred Make: Aarko/ Sant/ LP/ DS / Leader/ Zoloto/Kartar/NVR)

-

-

-

10

1550

15500

23

2730

62790

9

3600

32400

... More
150 mm

6

15700

94200

... More
Providing and fixing in position the following Dual Plate Non Return Valves PN 16 SG Iron Disc, flanges, Rubber Gasket, nut bolts etc as required with insulation.

-

-

-

... More
(Preferred Make: Castle/ Keystone/ Honey well/ Sant/ Leader/ Kartar/ NVR)

-

-

-

... More
150 mm

6

10950

65700

... More
Providing and fixing in position the following Flexible coupling with control unit , flanges, Rubber Gasket, nut bolts etc as required with insulation.

-

-

-

... More
(Preferred Make: Resistoflex/ Econosto/ honeywell/ Easyflex)

-

-

-

... More
65 MM

22

11500

253000

... More
150 mm

12

14700

176400

... More
Providing and fixing of Water Pressure Gauges of 100 mm dia gauge complete with SS syphon and ball valve alongwith duly welded socket etc as required.

34

1620

55080

... More
Preferred Make: Fiebeg/ H.Guru/ wika

-

-

-

... More
Providing and fixing of Industrial Type Thermometer, with duly welded socket etc as required.

22

1050

23100

... More
Preferred Make: Japsin/ HGuru

-

-

-

... More
Providing and fixing of Auto Air Vent Valves complete with socket, ball valve and nipple welding as required.

-

-

-

... More
(Preferred Make: Sant/ RC/ LP/ RB / Honeywell/ Castle/ Zoloto/ Kartar/ NVR)

-

-

-

8

1300

10400

... More
Providing & fixing in position the ball valves, M.S socket , M.S nipples as required for ceiling suspended A.H.U. coil drain complete with connection to A.H.U. condensed drain line as per the followings-

-

-

-

... More
Preferred Make : Zolato/ Sant/ Leader/Castle/ Honeywell/ Kartar/ NVR

-

-

-

... More
15 mm dia

45

750

33750

... More
Providing and fixing of expansion tank, fabricated out of 5 mm thick M.S. plate construction, duly insulated as per the specifications and shall be complete with 50mm dia outlets for system connection and overflow, make up connection, drain connection, drain valve, vent connections, valves and fittings as required. Expansion tank shall be complete min 19 mm thick Class O Nitrile insulation covered with Aluminium Cladding.

-

-

-

... More
SIZE : 1000 mm X 1000 mm X 1000 mm (high)

1

46100

46100

... More
Providing & Fixing of cubical type LT panel suitable for 415V, 3 Phase, 4 Wire 50 Hz Ac supply system having suitable front surface area fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having Suitable size extensible type TPN aluminium alloy bus bars of high conductivity, DMC / SMC bus bars of high conductivity,

-

-

-

... More
DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100mmx 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears (As per PWD BSR 2022) :- Panel fabricator Preferred Make Make : Ankit Elect/Precision/Eng & Eng/Zeniya

-

-

-

... More
Incoming

-

-

-

... More
1600 Amps 4 pole 50KA electrically operated Manually drawout type air circuit breaker with built in short circuit release, over current and earth fault protection with adjustable setting as per specification. (Incoming 3 phase and neutral supply with double loop earthing will be provided by department.) The panel shall complete with following accessories :

-

-

-

... More
3 Phase 96 x 96 sq.mm 0-1250/5 amps CTR digital ammeter 1 Nos

-

-

-

... More
3 nos. 1250/5 amps, 15 VA Class I CT’s.

-

-

-

... More
96 x 96 mm sq. 0-500 Volt digital voltmeter . 1Set

-

-

-

... More
BUS BAR

-

-

-

... More
1250 amps 3Phase and neutral Aluminium bus bars with colored heat shrinkable insulating sleeves to suitable size. 1 Set

-

-

-

... More
Outgoing

-

-

-

... More
125 Amp. 25kA,4 pole MCCB, Icu = 100% Ics with over current, short circuit and approved make complete with rotary handle and spreaders complete as required for Chiller Plants. 11 Set

-

-

-

... More
S/D starter for Primary Chilled water pumps with self illuminated Push buttons for ON & OFF, Ampere meter, MCB, contactors, timer, single phase preventer and O/L relays, suitable for 10 HP Motor. 3 Set

-

-

-

... More
125 Amp. 25kA,4 pole MCCB, Icu = 100% Ics with over current, short circuit and approved make complete with rotary handle and spreaders complete as required for Chiller Plants. For Secondary Pump Panel 1 Set

1

625000

625000

... More
Part 'B' BSR Items based on Electric BSR 2022

-

-

-

... More
Supply , Installation, Testing and Commissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

42

6412

269304

... More
P & F of Fire retardant flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

11

2023

22253

... More
Supply , Installation, Testing and commissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
0.60 mm

1600

970

1552000

... More
0.80mm

400

1155

462000

... More
Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed aerofoil shaped horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supply air grill with key operated volume control damper

20

10530

210600

... More
Return air grill without volume control damper

20

8438

168760

... More
Supplying, installing, testing and balancing of extruded Aluminium powder coated Air Diffuser and complete with Flush, 20mm flanges with PVC/neoprene gasket, anti – smudge frame and removable inner core to facilitate the adjustable of air control damper, square/round/ rectangular as required. Including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supply Air Diffuser with Volume Control damper

20

12219

244380

... More
Return Air Diffuser without Volume Control damper

20

9855

197100

... More
Supplying, installing and balancing of extruded Aluminium powder coated fresh air inlet louvers with bird screen & volume control damper fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

8371

16742

... More
Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6" pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

6

5128

30768

... More
Supply and fixing of acoustic lining of ducts with chemically cross link Oxide accetate foam open cell structure Acoustic Insulation with density 30 Kg / Sqm, UV protected and Class O Fire propperty Water Vapour absorption 0.002 gm / Sqcm, including cost of adhesive etc. complete in all respect. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
10 mm thick

200

755

151000

... More
Supply & fixing of external thermal closed-cell Nitrile rubber Insulation material FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 in form of sheet on duct including cost of adhesive (CPRX Compound) complete as required. All as per pre approved by Engineer in charge.

-

-

-

... More
13mm thick for indoor Application

1800

926

1666800

... More
Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25 mm

400

229

91600

200

296

59200

... More
Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia

-

-

-

... More
100 mm dia per running inch length

80

160

12800

... More
150 mm dia per running inch length

80

241

19280

... More
Providing and making wall openings in existing stone / Brick masonary partition wall complete with all requited T & P , Scafolding and providing lintel of required size and strength, repairing ,plastering and cleaning the site debrises as required.

60

738

44280

... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

4000

135

540000

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
50.0 Sq. mm

-

-

-

... More
3.5 core

300

457

137100

... More
10.0 Sq. mm

-

-

-

... More
4 core

200

192

38400

... More
6.0 Sq. mm

-

-

-

... More
4 core

1000

166

166000

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity 99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
1.5 Sq. mm

-

-

-

... More
3 core

1500

109

163500

... More
Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3.5 x 50.0 sq.mm

30

286

8580

... More
4 x 6.0 sq.mm

90

172

15480

... More
4 x 10.0 sq.mm

24

185

4440

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
100mm x 50mm x 1.6mm

100

553

55300

... More
150mm x 50mm x 1.6mm

100

675

67500

... More
300mm x 50mm x 1.6mm

100

1053

105300

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
8 SWG G.I. ( Hot Dipped ) Wire

80

20

1600

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 3mm Alum. Strip

70

133

9310

... More
25mm x 5 mm Alum. Strip

70

215

15050

... More
Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8337 -1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1.5 Sq.mm

900

6

5400

... More
SITC of Wall mounting cubical type DOL Starter panel for AHU made out of 1.6 mm thick sheet steel  powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of Blower motor comprising of over load protection relay, short circuit & single phasing protection, ON / OFF  push buttons,  ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Upto 4000 CFM

42

16500

693000

... More
Axial Flow Fan

-

-

-

... More
( Fire rated : 250 deg for 2 Hrs. )

-

-

-

... More
Providing & Fixing of Tube Axial Fans along with motor, Baseframe, canvass connections, anciallary structure required to suspended from slab/beams, vibration isolators, connection flanges, inlet bell mouth/inlet cone, outlet cone (sound level lesser then or equal to 70 DB @ 3 mtr.), back draft dampers etc. for following air quantities:

-

-

-

... More
Preferred Make: System Air/ Greenheck/ Humidin/ Flackwood

-

-

-

... More
23000 CFM 20mm SP

6

125000

750000

... More
IMPULSE JET FANS

-

-

-

... More
Providing & Fixing of Dual Speed Ductless Ventilation / Jet fans as per specifications for normal ventilation suitable for Normal ventilation and Smoke Extraction application. The complete fan assembly with all supporting, mounting structural frame, Casing, impeller, tranformer, starter & motor (the entire motor fan,controller etc., as a full package) shall need to be imported from manufacturer and certified as tested for 300 Deg C for 2 hours operation.

-

-

-

... More
The jet Impulse fans 355mm dia Fan is with mounting arrangements. Fan is capable of running at 300Deg. C at least for 2 Hours.Along with necessary protective grill & Structure work. Each fan shall be complete with Dual speed motor. Casing shall be made Galvanized Aluminum. The Motor shall be run on the electrical power suitable for 50Hz.

-

-

-

... More
Preferred Make: System Air/ Greenheck/ Humidin/ Flackwood

-

-

-

... More
3500 CFM Normal Mode/ 7000 CFM Fire Mode

8

60000

480000

... More
CO Sensor

-

-

-

... More
Providing and fixing of, continuous monitoring of CO and radicals concentration in ambient air, measuring range: 0-300 ppm CO with electro-chemical galvanic (Gel electrolyte) technology, sensor should be UL2075 certified, response time t90 30 sec, with anti-sleep feature, capable of providing multiple threshold to identify normal mode, invisible smoke mode and fire mode. It should provide both analog output and digital communication via RS485 serial interface with Modbus RTU. It should be uniquely addressable and suitable for connection in digital communication bus. Enclosure should have minimum fire retardant UL94: V0 rated with IP65 protection. Sensor cell should be plug-in, field replaceable, sensor life expectancy 7 years, replaceable sensor cell, CE certified. It Should confirm to EMC- Directive 2014/30/EU Preferred Make: EK Engineering, Siemens, Honeywell

8

17700

141600

... More
Combined PLC & MCC Panel for Fan operation

-

-

-

... More
Providing & Fixing of Control Panel with dual speed starters to operate jet Fans with PLC logic card Master control panel shall be separate and to be located in the main control room.

2

410000

820000

... More
Staircase and Lifts Pressurisation / SMOKE FRESH AIR Fan -

-

-

-

... More
Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) long casing tube/ vane axial flow fan of different capacity as mentioned below in standard MS construction. Entire fan model & AMCA Seal shall appear in technical submittal of fan. All the fans are synthetic enamelled painted/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS-325 IP55 with class `F' insulation. Motor should be VFD rated. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemispherical reverberant room conditions. Fans should be as per specification and drawings. Fan should be supplied with mounting bracket / arrangement. Preferred Make: Krueger / Greenheck / Systemair/caryaire

-

-

-

... More
17000 cfm at 20 mm static (for Stair case pressurization, )

6

158000

948000

... More
5000 cfm at 20 mm static (for lift well pressurization)

4

65900

263600

... More
Supply, Installation, testing and Commissioning of accoustically insulated ceiling / floor mounted Rectangular box type/circular type Inline fan, for toilet exhaust , ward normal exhaust constructed of GSS duly powder coated as per detailed specifications, complete with forward curved SISW fan, motor and drive suitable for 220 ± 10% volts, 1 phase, 50 Hz A.C supply, with necessary canvas connection etc complete in all respects. (Preferred Make: Humidin/Kruger/Nicotra/ Dynair/Revo/Greenheck/Systemair)

-

-

-

... More
500 cfm at 15 mm static

18

12840

231120

... More
200-300 cfm at 15 mm static

10

8600

86000

... More
1000 cfm at 15 mm static

20

19800

396000

... More
(IV) Air Cooling work

-

-

-

... More
Part 'A' BSR Items based on Electric BSR 2022

-

-

-

... More
Supply , Installation, Testing and Comissioning of factory assembeled double skin central evaporative cooling plant having specifications as per A, B, C, D, E

-

-

-

... More
A. Air washer comprising of 2nos Pre-Filters. First filter shall be 50mm thick Aluminium wiremesh filter & second filter shall be 50 mm thick MERV-8 synthetic media filter with efficiency 90 % down to 10 microns. Both filters to be placed over the common frame.

-

-

-

... More
B. Humidification section comprising of Wet pads 200 mm thick impregnated cellulose paper media ( Celdec pads ) with 2 bend PVC eliminator. The End plates of Pad & Eliminator shall be in SS 304 construction. Also, the inner blank offs of Wet section shall be in SS304 construction.

-

-

-

... More
C. Fan Section comprising of belt driven, DIDW Backward curved AMCA certified centrifugal fan with maximum air outlet velocity of 10m/s suitable for required cfm at 50 mm static pressure (Total static of the unit shall be verified by the OEM before the design & supply of the units). Fan & Motor should be mounted over Aluminium channel of suitable thickness and should be isolated from the unit's bottom panel by means of Spring isolators.

-

-

-

... More
D. TEFC High efficiecny IE-3 class motors as required with pulley, belt , Guard

-

-

-

... More
E. The unit shall be fabricated with frame work hollow extruded aluminium profile with 0.80 mm preplasticised GSS on outside and 0.80mm 275gsm plain GSS on inside complete with 25 mm thick CFC free PUF insulation of minimum 40 kg/cum density sandwiched in between inner and outer skins. Unit should have MS powder coated legs to give height to unit's base channel from the floor surface. SS-304 ( 18 g ) Sump, UPVC Internal piping, make up, drain & quick fill and drain connection, Butterfly/Gate valves for pumps, make up, drain & quick fill and drain connections of sump, 2 no. Vertical Pumps of suitable capacity to be placed inside the unit's housing (external pumps are not acceptable) ,Y strainers and necessary fittings, Concrete Blocks / M S stand, anti vibration pads etc.as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
more than 7500 cfm to 15000 cfm

100000

26

2600000

... More
more than 15000 cfm to 25000 cfm

100000

23

2300000

... More
SITC of Wall mounting cubical type Starter panel made out of 1.6 mm thick sheet steel  powder coated enclosure designed as per Switchgear OEM type -2 coordination chart and suitable for operation of following cfm range Air Washer's Blower motor, pump comprising of over load protection relay, short circuit & single phasing protection, ON / OFF  push buttons,  ammeter, voltmeter, indicating lamps, MCB etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
more than 7500 cfm to 15000 cfm

6

23281

139686

... More
more than 15000 cfm to 25000 cfm

6

32394

194364

... More
Supply , Installation, Testing and Comissioning of wall mounted remote ON/OFF Push Button station for AHU/Air washers made out from powder quoted CRCA sheet of 16 SWG , illuminated ON/OFF push button including making connections etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

12

6412

76944

... More
P & F of Fire retardent flexible canvass connection made of fibreglass weave having silver grey silicon rubber coating, of height 200 mm with sufficient fold to avoid transmission of vibration with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

50

2023

101150

... More
SITC of VFD OEM fabricated VFD cum Bypass starter panel Confirming to IEC60721-3-3, IEC60068-2-60 & IEC60068-2 for variable torque applications, 3C3 avg., 200% torque producing capability at min freq of 0.5 Hz, integrated with 3 to 5% of input reactor or built in DC reactor, Max output frequency 400Hz, built in braking chopper till 30KW, built in RS485 Modbus RTU, Min 7DI, 2DO, 2AI, 1AO, onboard control supply of 24V -150 mA for external operations, RJ45 port, Monitoring parameters – V, I, Torque, Freq, RPM, Watt Hour, DC bus voltage, Analog input V or mA, I/O Status, PID loop monitoring, Torque speed, speed limit, Cooling fan, Protection functions – Ground fault, Over current, Overload, UV/OV, Under/over torque, I/P & O/P phase loss, DBR O/L, inverter over hit alarm, DC bus charge LED indication, heatsink thermistor open detection, stall prevention, fault history of min 4 last faults. Bypass starter shall be provided as per type 2 coordination etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
5.5 KW

6

92954

557724

... More
7.5 KW

6

100959

605754

... More
Supply , Installation, Testing and Comissioning of site fabricated ducting made from GI sheet metal conforming to IS:277 with a zinc coating grade not less than 120 GSM (both side inclusive) & fabricated as per IS:655 and as per approved drawings & designs including the cost of hangers, supports, angle, expansion fasteners , closed cell neoprene gasket T&P etc. as required of following thickness. Test Certificate for Galavanizing with lot no. to be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
0.60 mm

1000

970

970000

... More
0.80mm

1000

1155

1155000

... More
1.00mm

400

1386

554400

... More
Supplying, installing, testing and balancing of double louvered of extruded Aluminium Powder coated supply/return air grills of various sizes, Each grill shall be with fixed aerofoil shaped horizontal front bar at 0 deflection and back adjustable vertical louvers, air distribution grid for straightening the air flow through the collar and register including fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supply air grill with key operated volume control damper

50

10530

526500

... More
Supply , installation, testing & balancing of 20 Gauge G I Damper with brass bushes and 6" pitch multiblade box type galvanised sheet steel construction volume control damper for Ducting and air washers to be provided with suitable links and quadrants for control of volume of air as per specifications complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

20

5128

102560

... More
Supply and fixing of acoustic lining of ducts with chemically cross link Oxide accetate foam open cell structure Acoustic Insulation with density 30 Kg / Sqm, UV protected and Class O Fire propperty Water Vapour absorption 0.002 gm / Sqcm, including cost of adhesive etc. complete in all respect. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
15 mm thick

450

978

440100

... More
Supply and fixing duct insulation with 50 mm thick Expanded Polystyrene Thermocol (ESP) sheet of density 24 kg/cu.m after applying two coats of cold setting adhesive (CPRX Compound) and binding sheet with chicken wire mesh and applying cement mortar plaster (1:4) including primer & painting (suitable for outdoor aplication) matching with building colour or as per direction of Engineer incharge as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

700

985

689500

... More
Providing and making wall openings in existing stone / Brick masonary partition wall complete with all requited T & P , Scafolding and providing lintel of required size and strength, repairing ,plastering and cleaning the site debrises as required.

200

738

147600

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
6.0 Sq. mm

-

-

-

... More
4 core

250

166

41500

... More
16.0 Sq. mm

-

-

-

... More
4 core

900

232

208800

... More
Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.

1150

39

44850

... More
Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
4 x 6.0 sq.mm

12

172

2064

... More
4 x 16.0 sq.mm

12

189

2268

... More
Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
150mm x 50mm x 1.6mm

250

675

168750

... More
Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-

-

-

-

... More
(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole

-

-

-

... More
(b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts

-

-

-

... More
© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt

-

-

-

... More
(d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.

-

-

-

... More
(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.

-

-

-

... More
(e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25 mm thick and 3 Mtr. Long

6

7955

47730

... More
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 6mm G.I. ( Hot Dipped ) Strip

200

196

39200

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
8 SWG G.I. ( Hot Dipped ) Wire

800

20

16000

... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

600

135

81000

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level

-

-

-

... More
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)

3

4707

14121

... More
Plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish :

-

-

-

... More
20mm thick

5

471

2355

... More
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding:

-

-

-

... More
New work (Two or more coats applied @ 3.84 kg/10 sqm).

5

121

605

... More
Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia

-

-

-

... More
50 mm dia per running inch length

200

80

16000

... More
100 mm dia per running inch length

196

160

31360

... More
150 mm dia per running inch length

150

241

36150

... More
200 mm dia per running inch length

150

334

50100

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-

-

-

-

... More
(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided

-

-

-

... More
(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.

-

-

-

... More
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )

-

-

-

... More
(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.

-

-

-

... More
(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.

-

-

-

... More
(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )

-

-

-

... More
(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.

-

-

-

... More
(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

5

5975

29875

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

50

542

27100

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS

1

3252

3252

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Ring type tape wound CT

-

-

-

... More
C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA

3

788

2364

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

2

170

340

... More
Blue / white Colour

1

260

260

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
4 pole MCCB With Thermal Magnetic release

-

-

-

... More
up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

12

7112

85344

... More
250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,

1

19792

19792

... More
Part 'B' BSR Items based on Civil BSR 2022

-

-

-

... More
P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:

-

-

-

... More
Exposed on wall

-

-

-

... More
20 mm Dia. Nominal bore 'B' Class

100

282

28200

... More
25 mm Dia. Nominal bore 'B' Class

100

360

36000

... More
32 mm Dia. Nominal bore 'B' Class

100

436

43600

... More
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :

-

-

-

... More
Gun-metal 20mm nominal bore.

10

358

3580

... More
Gun-metal 25mm nominal bore.

4

529

2116

... More
Gun-metal 32mm nominal bore.

4

703

2812

... More
Part 'C' Non BSR Items based on Market Rates

-

-

-

... More
SITC of Wooden frame 40 mm x 75 mm size of Cheed wood for Grills.

500

503

251500

... More
P & F of Canvass connection of required size for Air cooling machines.

12

1787

21444



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.