Rajasthan State Road Development And Construction Corporation Limited Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan State Road Development And Construction Corporation Limited - RSRDC Tender

Works
Eprocure
Opening Date27 May 2021
Closing Date7 Jun 2021
Tender Amount₹ 64,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Medium point (up to 6 mtr.)

26

-

360

... More
Long point (up to 10 mtr..)

90

-

465

... More
Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & it's all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modular switch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
On board

23

-

246

... More
Short point (up to 3 mtr.)

2

-

315

... More
Medium point (up to 6 mtr.)

2

-

432

... More
Long point (up to 10 mtr..)

5

-

532

... More
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
MMS ( IS:9537 P - III ) PVC conduit

-

-

-

350

-

30

1400

-

36

150

-

60

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( 10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
3x 1.5 sq.mm

700

-

36

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

750

-

50

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

500

-

71

... More
2 x 6.0 sq. mm. + 1 x 2.5 sq. mm.

200

-

100

... More
4 x 10.0 sq.mm

180

-

274

... More
2 x 6.0 sq.mm

180

-

81

... More
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

20

-

397

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single pole MCB

-

-

-

... More
6 A to 32 A rating

72

-

142

... More
Four pole MCB

-

-

-

... More
40 A rating

3

-

1211

... More
50-63 A rating

5

-

1265

... More
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) as per PWD specification for electrical Works with ISI marked (IS:12640-1) / conforming to IEC 61008 -1 , rated conditional s/c current of 10 KA, truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating, minimum phase termination capacity of 50 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Two pole 100/300mA sensitivity

-

-

-

... More
40 A rating

9

-

1635

... More
Four pole 100/300 mA sensitivity

-

-

-

... More
63 A rating

3

-

2142

... More
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c),(d) below:-

20

-

3443

... More
(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure

-

-

-

... More
(b)panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear

-

-

-

... More
[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.

-

-

-

... More
(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

25

-

445

... More
Providing & Fixing of BIS approved Current Transformer as per PWD specification for electrical Works ,ISI marked as per IS 2705-1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
C T Class 1, Ratio upto 150/5, Burden 5 VA

6

-

355

... More
Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

4

-

127

... More
Blue / white Colour

2

-

209

... More
Providing & Fixing of IP 51 Multi function meter as per PWD specification for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution & complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Multifunction LCD meter with V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh, Run hours, On hours, Phase angle, Interrupts, THD, Events, Neutral Current class 1 accuracy with RS485 port.

1

-

7223

... More
Providing & Fixing of IK 09 recessed/surface mounting heavy duty Flexi/Row TPN sheet steel 1.6 mm thick Distribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 /conforming to IEC 61439-3.Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, including making internal DB terminations with copper lugs and with detachable gland plate, testing etc. as required complete in all respect.OEM shall have submit NABL / CPRI / ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
IP-43 Double door

-

-

-

... More
4 Row 56 Module(14 module per row)

3

-

3184

... More
Providing & Fixing of recessed/surface mounting heavy duty sheet steel 1.6 mm thick End Box as per PWD specification for electrical Works for distribution board duly phophatised powder coated complete as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
For TPN 12 way DB

3

-

677

... More
Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 A 3 pin shuttered socket

204

-

86

... More
25 Amp. 2 Module Socket

15

-

162

... More
Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 A one way switch

68

-

51

... More
16 Amp. 1 Module switch With Led Indicator

68

-

104

... More
32 Amp. 2 Module switch With Led Indicator

15

-

266

... More
Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
5 step fan regulator 100 watt 2 Module

10

-

310

... More
Providing & Fixing of following modular accessories as per PWD specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Blanking plate

30

-

15

... More
Providing & Fixing of following size mounting grid plates with cover plates as per PWD specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1/2 Module

102

-

48

... More
3 Module

20

-

63

... More
8 Module

70

-

118

... More
Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per PWD specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1-2 Module

34

-

53

... More
3 Module

20

-

74

... More
8 Module

70

-

128

... More
Providing & Fixing of ISO certified company made vergin material PVC trunking system as per PWD specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tee, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
80mm x 50mm

50

-

621

... More
100/105mm x 50mm

80

-

740

... More
SITC of chemical Gel earthing system of Dual Pipe Technology made of with "B" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :-

-

-

-

... More
(a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .

-

-

-

... More
(b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts

-

-

-

... More
©Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.

-

-

-

... More
(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.

-

-

-

... More
(e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell

-

-

-

... More
GI pipe 3000 mm long, 80 / 50 mm, Terminal 50 mm x 6 mm GI Strip

6

-

6866

... More
Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 3mm copper strip

60

-

516

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
8 SWG copper Wire

80

-

81

... More
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

500

-

89

... More
SITC of IP 40 quick make and quick break 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders, etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
With Thermal Magnetic release

-

-

-

... More
up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

7

-

5767

... More
200 Amp , 35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu

1

-

13661

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-

-

-

-

... More
(a) Material :- H4- Grade aluminium conductor of purity 99.6 % & as per IS:1554 P-I / IS :7098 P - I

-

-

-

... More
(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .

-

-

-

... More
(c) OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Armoured Cable

-

-

-

... More
16.0 Sq. mm

-

-

-

... More
4 core

150

-

123

... More
25.0 Sq. mm

-

-

-

... More
4 core

150

-

164

... More
50.0 Sq. mm

-

-

-

... More
3.5 core

300

-

235

... More
Supplying and making one end termination with heavy duty brass compression gland (as per IS 12943- 1990) SIBG type, heavy duty aluminium lugs (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
4 x 16.0 sq.mm

4

-

88

... More
4 x 25.0 sq.mm

4

-

96

... More
3.5 x 35.0 sq.mm

4

-

107

... More
Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD 10 % , p.f.≥0.95,CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.

-

-

-

... More
OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
48W LED light fixture 2'x2' with acrylic / prismatic front cover.

40

-

2724

... More
Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD 10 % ,p.f.≥0.95, CRI 80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.

-

-

-

... More
OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.

-

-

-

... More
Recessed Mounting

-

-

-

... More
LED Downlight 14/15W

28

-

687

... More
LED Downlight 18/20W

10

-

725

... More
Supply & Laying following size' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
32mm dia

25

-

239

... More
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor 0.95 ,driver Efficiency 85% , THD(I) 10% , driver current 1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min =4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index 70 and CCT 5700K ±355K. Driver current 1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.

-

-

-

... More
OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
High Power LED Flood Light 80W

10

-

6302

... More
Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
300 mm sweep(900/1400 RPM)

2

-

2252

... More
Supply, Fabricating & installing following sizes of powder coated perforated M.S. cable trays with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with MS suspenders including bolts & nuts , fastners, supports, painting suspenders etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
150mm x 50mm x 1.6mm

60

-

359

... More
300mm x 62.5mm x 2.0mm

160

-

688

... More
Supply & Fixing of ABC Type (MAP 50) type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, with Dry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket including initial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

4

-

4336

... More
Supply & Fixing of current and valid BIS certification IS: 15683:2018 approved Portable fire Extinguisher, Carbon‐dioxide type flat base including valve, discharge hose of not less than 10 mm dia. min. 600 mm long & complete in all respects including initial fill with C02 gas confirming to IS:307‐1966 filled to a filling ratio of not more than 0.667 and wall suspension bracket . bidder must have valid PESO license to refill and store compressed gas cylinders as per Gas Cylinder rules 2004 , vessel should be PESO Approved. carbon dioxide gas shall conform to IS 15222 with latest amendment. Co2 Cylinder shall be conform to all the requirement given in IS 7285:2004. Serial no. and date of manufacturing should be embossed or printed on the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Capacity 4.5 Kg.

4

-

10073

... More
Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required.

15

-

108

... More
Providing & Fixing of ISO Certified company made BEE Approved copper wounded 1200 mm sweep BLDC technology power saving ceiling fan with longer life span and low maintenance 5 star rated which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 215 CMM, speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod up to 30 cm with secondary support safety cable , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Without Remote

10

-

2432

... More
Providing & Fixing of heavy duty, copper wound , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade wall mounting oscillating type air circulator as per PWD specification for electrical Works, conforming to IS:2997, including fixing with anchor bolts, regulator making connection testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
450 mm sweep With wall Mounting and three speed regulator

20

-

5181

... More
Supply , Installation, Testing and Comissioning of Floor standing ISO 9001:2015 & 14001 or higher level certified company made Communication enclosure (Rack) of 600 MM Depth with made from CRCA & hot dip powder coated,Vertical Mounting Rail 1.6 MM with 'U'Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Accessories like: 5 Nos of 19" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 2 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.

-

-

-

... More
24U Floor Standing Enclosure

1

-

28557

... More
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Multi Mode LIU 6 Ports

2

-

5709

... More
Supply, Installation, & Testing of Indoor duplex Multimode patch cord (50/125 µm made of glass fiber optic with LSZH jacket, Multimode G652.D Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20 as per latest ammendments of TIA/EIA 569B.3, as per requirements complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

2

-

1475

... More
Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

12

-

969

... More
Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
6 fiber

200

-

125

... More
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.

-

-

-

... More
Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord

-

-

-

85

-

206

... More
2 Mtr

70

-

272

... More
Supply, Installation, Testing and Comissioning of Rack mounted 19" 1U, 24 Port Unloaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels (without I.O.) with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel, . There should be a provision for each port/jack on the panel and reusable removable on field from the panel complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

4

-

1792

... More
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2000

-

30

... More
Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.

-

-

-

... More
Cat 6, Un-sheilded Information Outlet

68

-

259

... More
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Single Aperture

68

-

100

... More
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit of apropriate thickness related to its dia as per PWD specification for electrical Works along with accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, screwas etc. as required including cutting the wall and making good the same as required all as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

200

-

79

... More
Supplying and drawing FRLS PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228. FRLS PVC insulation which provides better fire retardant properties then normal PVC & also emits Low Smoke in case of fire & use type A insulation PVC, in existing conduit including , all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
2 x 1.5 sq.mm

250

-

27

... More
Supply , Installation, Testing and Comissioning of Hot pluggable Small Form Factor Pluggable (SFP Module), 1000BASE-LX, 1G Fiber Channel, LC Type Duplex Connector, 1310 nm laser transmitter, Should support distance upto 10 km on 9/125 um of data rate upto 1.25 Gb/s on bi-directional data links. Should also support industrial temperature, should have metal enclosure for lower EMI. The transceiver should be ROHS Compliant. (For Each SM Fiber) complete in all respect. Switch & SFP module should be of the same make. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.

2

-

29494

... More
SITC of UL 10th edition / EN54 VDS approved IP40 Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm ) type Photo smoke detector with mounting base & LED etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
with inbuilt isolator or with isolator base

22

-

3071

... More
Supply, Installation, Testing and Commissioning of IP52 Addressable (MCP) Manual Break Glass/ flap Unit (Double action) shall have UL/EN54 certification shall be constructed of Lexan with clearly visible operating instructions provided on the cover. The word FIRE should appear on the front of the stations in raised letters, including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
with inbuilt isolator or with isolator module

2

-

3140

... More
Supply, Installation, Testing and Commissioning of IP 40 Stand alone Loop Powered Addressable sounder with 5 different tone variants selection options & adjustable sound pressure by 5 levels, the sound pressure 90 dB , it should be programmed from the panel. Shall have EN54 /UL Certification including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
with inbuilt isolator or with isolator module

2

-

2777

... More
Supply, Installation, Testing and Commissioning of Microprocessor based inteligent, Analogue addressable fire alarm panel with CPU redredundancy & min 640 charactor/ 6" touch screen display , shall have UL 10th edition / EN54 VDS approved certification, modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 250 detectors & devices with Loop length up to 1.5 KM. Minimum 5000 history event facility . Panel shall be Compatible for Seamless integration with PA system and both system should be of the same make. The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, inbuilt networking port (both RS485 & Ethernet),Serial port for printer, two supervisory inputs,two position key switch and USB port for programming. including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1 - Loop Panel

1

-

161329

... More
Supply installation testing and commisisioning of IP 40 Beam detector along with Addressable interface module having a coverage area with a distance of min. 10 m and max. 100 m, Operating temperature range: -20 C to +55 C, Response sensitivity of 40% , shall have UL/EN54 certification including transmitter and receiver unit with mounting base & LED etc including the cost of all accessories,connecting wires,fixing arrangement, Labour, T&P etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

2

-

54031

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armoured copper cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points (a), (b), (c), mentioned below:-

-

-

-

... More
(a) Copper conductor of electrlytic grade copper, purity 99.97 % ISI marked as per IS:1554 P-I / IS :7098 P - I

-

-

-

... More
(b) conductor shall made of copper rods confirming to IS 613-1964, IS 3975-1999 for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures

-

-

-

... More
(c) OEM Must have ISO 9001 & 14001 certifications & its own in house NABL lab setup for all testing facilities for cables . Appropriate type test certificate / OEM test report shall be submitted . All above as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Armoured

-

-

-

... More
10.0 Sq. mm

-

-

-

... More
4 core

200

-

389

... More
Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape as per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
4 x 10.0 sq.mm

6

-

88

... More
Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia

-

-

-

... More
150 mm dia per running inch length

60

-

193

... More
Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field-programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. compliant to IS 13875, & IEC 61326. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Digital type Confirming to IEC 62053-21

-

-

-

... More
Below 500 A

1

-

1039

... More
Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurments, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. Field-programmable high and low threshold values, meter shall compliance of IS 13875 & IEC 61236. as required. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab test reports before execution &All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Digital type

1

-

1053

... More
Supply , Installation, Testing and Comissioning of Interconnecting refrigerant copper pipe for split of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Material Test Certificate required with each supplied material. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

251

-

1166

... More
NON BSR ITEMS

-

-

-

... More
Supply, Installation, Testing and balancing of powder coated /Anodised extruded aluminium construction inlet fixed single air louvers with bird screen for Exhaust air of size upto 1.0 sqft area, Installation has been done on the Exhaust Fan of make Systemair / Ravistar / Trox/MetalJoint/Airflow.

2

-

1200

... More
SITC of raceway confirming to EN 50 085-2-2, IP-20, IK-08 for distributing cablling for screed floora installation & particularly suitable for applications requiring EMC screening material/GI raceways made up of pregalvanized sheet (DX51D-Z120 MAC) in desired color, non corrosive, non flame propagation, with 2 to 2.5 mtr, standard length/standard depth 25mm / 38mm, thickness 1.6 mm for raceways, 1.0 mm for partition with coupler for joining raceways including making jhiris on floors/wall if required of following sizes. Make: legrand / MK

-

-

-

... More
100 x 38 mm

100

-

2756

... More
SITC of GI junction box with removable precuts knockouts provided for raceways resistance to vertical load over a small area, 500N and for large surface area 2000N with adjustable height 50 to 70mm with flyover as required . Make: legrand/MK

-

-

-

... More
100 x 38 mm

8

-

2560

... More
SITC of Intelligent Ethernet POE Switches providing 24 x 10/100/1000 Fast Ethernet POE ports- 370W or better  and 4 dual purpose uplink (provision for Copper / Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software (Approved makes: CISCO WS-C2960X-24PS-IN, Avaya, Ericsson)

4

-

65025

... More
Supply, Installation, Testing and commissioning of 1/2.7 inch or better CMOS, 2MP indoor IR 1080p Professional IP HD Varifocal lens Dome High definition camera, Power-over-Ethernet, 1920 x 1080 sensor pixels, IR LED high efficiency array for Distance capability of 15 m (50 ft), intelligent Dynamic Noise reduction, Area-based encoding, multiple streams, tamper & motion detection, White balance, Backlight Compensation, Motion detection, Tamper alarm, Varifocal 3 to 10 mm lens, P Iris / DC Iris, F 1.3/1.4, ONVIF Profile S, Wide dynamic range 76 dB / WDR- forensic capture, fully configurable quad streaming or better, CE / UL / FCC Certified. The wall mounting bracket of camera has to be of same make as of camera OEM. The camera, software, storage should be of the same make for seamless integration with each other MAF: Tender Specific OEM authorisation is mandatory for bid consideration, (Approved Makes: Axis, Bosch, Avigilon)

11

-

27540

... More
Supply, Installation, Testing and commissioning of Server Storage with video management solution for up to Professional edition of 16 channels with POE port for all channel. It should also have IP video management solution loaded with 10 TB HDD storage, 120 mbps throughput per unit with 1GbE Network connectivity, with Advanced user and alarm, management, Robust, secure operation — instant real time access to video. There should no separate need of NVR. i.e. The system should be such that the video recording should be done directly on storage array without the use of NVR/ DNR & be fully loaded and fully functional with Microsoft Operating System and OEM application; Video Management System & Video Recording Manager including Video Streaming Gateway, Dynamic Transcoding (Approved Makes: Axis, Bosch, Avigilon)

1

-

174000

... More
SITC of Workstation latest Intel® i5 processor, Intel Chipset motherboard, 08 GB RAM, 1 TB SATA HDD at 7200 rpm, with 4GB GPU type higher end Graphic card for H.265 compression technique with dual display ports/DVI/ HDMI port, Giga LAN Card, wireless Keyboard, wireless optical Mouse, (Approved Makes: Dell, HP, Lenevo)

2

-

76500

... More
SITC of 17'' Screen for viewing for Storage (Approved Makes: HP / Dell / IBM / Lenova )

1

-

6120

... More
SITC of 65'' Flat Smart Screen HD Profesional LED with remote control and wall mount unit / floor stand complete with making connections etc

1

-

165000

... More
Supply & Laying of 2 Core Shielded Cable for connectings Microphones with related conduits / fittings / termination, etc. Make:-Belden/. Kramer / Crystal / Deepcab / sircco

65

-

41

... More
Supply & testing and commissioning of high speed HDMI cables , Molded connectors : Yes , Gold Plated connectors: Yes , HDCP Complaint : Yes , Flame Test : Cl 2 including making connections etc complete in all respect. Of Kramer , Extron, Creston make.

24

-

2500

... More
Supply, Installation, Testing & Commissioning of Digital Chairman Unit with Priority Button and Discussion Device that shall enable participants to take part in a discussion by speaking into a microphone and listening to proceedings on a loudspeaker. The device shall have Plug-and-play functionality, Compact, attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone with flexible stem with Loudspeaker integrated into front of device having facility of headphone as well with Automatic level reduction when microphone is activated (configurable via web browser application of Control Unit): prevents acoustic feedback from headphone to microphone. GSM immunity with having Frequency response 200Hz-12.5kHz, Loudspeaker nominal output 72dB SPL. ((Approve Makes:- Bosch(CCS1000D) or equivalent specifications / models in Beyerdynamic, Televic)

1

-

40000

... More
Supply, Installation, Testing & Commissioning of Digital Delegate Unit with Speak Button and Discussion Device that shall enable participants to take part in a discussion by speaking into a microphone and listening to proceedings on a loudspeaker. The device shall have Plug-and-play functionality, Compact, attractive, ergonomic design, with LED indicator in the Discussion Device and in head of microphone with flexible stem with Loudspeaker integrated into front of device having facility of headphone as well with Automatic level reduction when microphone is activated (configurable via web browser application of Control Unit): prevents acoustic feedback from headphone to microphone. GSM immunity with having Frequency response 200Hz-12.5kHz, Loudspeaker nominal output 72dB SPL. (Approve Makes:- Bosch(CCS1000D) or equivalent specifications / models in Beyerdynamic, Televic)

8

-

38000

... More
Supply, Installation, Testing & Commissioning of Control Unit with inbuilt recorder with Intuitive touch-buttons on the front panel for easy configuration and operation purposes. Intuitive LED indicators for clear and immediate feedback on the system settings.Web browser control – it shall be possible to use a web browser application to view and manage system settings.System control for up to 80 Discussion Devices.Hot swap of Discussion Devices, without having to power down the system. Plus/minus buttons and green LED indicators for setting the volume range of all connected Discussion Devices. Microphone-mode selection button and green LED indicators for selecting one of the following microphone operating modes: ‘open mode’, ‘override mode’, ‘voice activation mode’, and ‘push to talk (PTT) mode’. Number of Open Microphones (NOM) button and green LED indicators for selecting the number of microphones that can be activated at the same time. It shall be possible to select up to four open microphones at the Control Unit. Built-in Digital Acoustic Feedback Suppression (DAFS). USB connector on front of unit for connecting a USB memory stick. Gain reduction due to number of open microphones (NOM) 1/SQRT (NOM) Sample rate 44.1kHz Nominal input (85 db SPL) 0.5% Max. input (110 db SPL) 0.5% (Approve Makes:- Bosch (CCS1000D) or equivalent specifications / models in Beyerdynamic, Televic)

1

-

165000

... More
Supply & Installation of wooden cabinet for accomodating PA system equipment. The design of the cabinet shall be approved from Engineer incharge.

1

-

12000

... More
Supply, Installation, Testing & Commissioning of Connectors & Cable Clamps of OEM Make Only (Approve Makes:- Bosch(CCS1000D) or equivalent specifications / models in Shure,Beyerdynamic, Televic)

10

-

1075

... More
SITC of 10 KVA 3 Phase Input, 1 Phase Output advance DSP controlled UPS with IGBT based rectifier, LCD display, double conversion / Digital Signal Processing UPS, with isolation transformer, with 30 minute battery back up, with required cabling for incoming & outgoing connection (Approved makes: Emerson / Numeric / APC)

1

-

430000

... More
SITC of Variable Refrigerant Flow modular type airconditioning system Inverter Controlled with stepless wide Range of Capacity Control with minimum Steps of 1Hz complete with indoor & outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping , full charge of refrigerant gas & oil (as per reccomendation from OEM), control cabling etc. as per detail given in specifications and having following items: Refrigerant to be used shall be R-410 A.

-

-

-

... More
Modular type outdoor unit equipped with highly efficient multi scroll / Twin Rotary compressors with fully inverter (one or more) type compressors special heat exchanger, low noise condenser fan with DC variable speed motor, auto address setting, auto check function for connection error, with sandwitch type vibration isolator rubber pads, auto address setting and capacity as mentioned below & as list of Make :- HITACHI /TOSHIBA /MISTUBHISHI /DAIKIN /VOLTAS /OGENERAL /BLUE STAR /CARRIER /LG. THE COMPLETE AC SYSTEM SHALL BE IN THE COMPREHENSIVE MAINTANANCE PERIOD OF FIVE YEARS AND SHALL BE MAINTANED BY THE OEM OR ITS AUTHORISED DISTRIBUTOR.

-

-

-

... More
18 HP Heat Pump Type (Cooling & Heating).

2

-

360000

... More
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve,outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Make :- HITACHI/TOSHIBA/LG/ MISTUBHISHI/ SAMSUNG /DAIKIN/VOLTAS /OGENERAL.

-

-

-

... More
2 ton Cassette type unit

2

-

28000

... More
3.2 ton Cassette type unit

3

-

32787

... More
4.0 ton Cassette type unit

3

-

44960

... More
SITC of Indoor unit of various type and capacity as mentioned below. The unit shall be equipped with suitable electronic expansion valve, which can communicate with the controller in the condensing unit, multispeed motor, self diagnostic type Corded remote controller with NO/NC contact for key tag operation in VRV/VRF system, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections, fresh air intake connector for cassettes etc. of various capacities as per specifications and drawings & as list o Make :- HITACHI/TOSHIBA/LG/ MISTUBHISHI/ SAMSUNG /DAIKIN/VOLTAS /OGENERAL.

-

-

-

... More
1.0 TON Hiwall type unit

3

-

22500

... More
2.0 TON Hiwall type unit

3

-

36125

... More
Supply, installation, testing & commissioning Refrigerant 'Y'Joint of various sizes required for distribution of refrigerant in copper piping etc. complete as per specificationss & Make :- HITACHI/TOSHIBA/LG/ MISTUBHISHI/ SAMSUNG /DAIKIN/VOLTAS /OGENERAL.

17

-

5800

... More
Supply, Installation, testing & commissioning of main central remote controller system with coloured LCD display touch panel suitable for above mentioned Indoor Units to operate/ monitor temperature setting etc & Make :- Make :- HITACHI/TOSHIBA/LG/ MISTUBHISHI/ SAMSUNG /DAIKIN/VOLTAS /OGENERAL.

1

-

122000

... More
Providing and fixing of cPVC drain water piping complete with fittings, support with MS hanger as per specification and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation. Make: cPVC Pipe -Supreme / Astral / Kisan. Insulation - Armaflex / Supreme/ Superlon / Aflex /Kflex.

-

-

-

... More
32 mm dia O.D

90

-

136

... More
25 mm dia O.D

147

-

94

... More
Supply & Laying of ISI marked Copper conductor shielded control cum transmission cable in PVC conduit for looping between indoor & outdoor VRV system & to main Central remote controller system. Make:- Copper wire - Finolex / Polycab /KEI / RR kable. PVC Conduit - Precision / AKG / BEC / RICHA.

-

-

-

... More
3C X 1.5 Sq. mm

500

-

150

... More
S & F of 2.0 mm thick (both base & cover) hot dipped galvanized MS sheet raceway of required size & shape The raceway shall be fixed on the floor / Wall with the help of suitable support (Surface area of Raceway to be measured )

40

-

2450

... More
Supply & fixing of external thermal closed cell elastomeric class O nitrile rubber tubular insulation between each set of indoor & outdoor units as per specificationsnitrile including cost of adhesive complete as per specification and as required. Of Make Armaflex / Supreme/ Superlon / Aflex /Kflex.

-

-

-

... More
19 mm thick insulation

500

-

45



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.