Rajasthan State Road Development And Construction Corporation Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,60,300Document Cost
₹ 1,180Tender Fee
₹ 1,500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RSRDC_428524_1Tender No
RSRDC NIT 280/2024-25 (Sl-1)Tender Authority
Rajasthan State Road Development And Construction Corporation Limited ViewPurchaser Address
-Website
http://http://roads.rajasthan.gov.in/content/raj/roads/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Corigendum2 PWD Electric BSR 2022
Agreement, RTPP Act, Govt. Orders/Circulars etc.
BOQ Items
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
8013
49
392637
Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
Cat 6, Un-sheilded Information Outlet
76
398
30248
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
Single Aperture
109
81
8829
Dual Aperture
145
101
14645
Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
1-2-3 Module
308
98
30184
Supply, Installation, Testing and Comissioning of Rack mounted 19" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
Modular Patch Panel Loaded with Cat -6 I/O
5
8765
43825
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A /Class E/Ea patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors with strain relief boots as per ANSI/TIA/EIA 568-C.2 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568C.2, ISO/IEC 11801, EN 50173, IEC 60603-7-51, EN 60603-7, IEEE 802.3an minimum requirement for 1G BASE-T to 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, should support IEEE 802.3af / IEEE 802.3at for POE applications, Minimum 750 to 1000 mating cycles in plug contacts for long durability, Should support Ethernet 10GBASE-T, 1.2 Gb/s ATM, Token ring 4/16, Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP).All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
1 Mtr
140
223
31220
Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
6 fiber
2100
94
197400
Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm (OS1/OS2) made of glass fiber optic with LSZH jacket, F8 2.0x4.1 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2) Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20. Zirconia (ceramic) ferrule with a PC polished endface geometry, connectors should be tuned in accordance with IEC 61755-3-1 and qualified in acc. with IEC 61753-1 for category U (uncontrolled environment, duplex clip and white plastic dust cover, should comply to delta IL 0.2 dB after 500 mating cycles, there should be an optional Visual coding, mechanical coding and lock protection on the patch cords which can be added on later stage. patch cords's performance should be acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, as per requirements.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
Single Mode Patch Cord 3 Mtr.
42
1823
76566
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, Singlemode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable duplex adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirment complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
12 Ports
12
8759
105108
24 Ports
2
10778
21556
Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm (OS1/OS2) made of glass fiber optic, with semi-tight buffer PA/PBT, Ø 0.9 mm, yellow, singlemode G652.D (9/125 µm (OS1, OS2), should have length of min 1.5m, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, Should be delta IL 0.2 dB after 500 mating cycles, It should be Zirconia (ceramic) ferrule with a PC polished endface geometry connector qualified in acc. with IEC 61753-1 for category U (uncontrolled environment). and qualified in acc. with IEC 61753-1, Performance acc. to IEC 61753-1 (Table A.12) as per latest ammendments of TIA/EIA 569B.3, Standard Specification as per requirments.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
192
1212
232704
Supply , Installation, Testing and Comissioning of Hot pluggable Small Form Factor Pluggable (SFP Module), 1000BASE-LX, 1G Fiber Channel, LC Type Duplex Connector, 1310 nm laser transmitter, Should support distance upto 10 km on 9/125 um of data rate upto 1.25 Gb/s on bi-directional data links. Should also support industrial temperature, should have metal enclosure for lower EMI. The transceiver should be ROHS Compliant. (For Each SM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
48
25499
1223952
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent Giga Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class Catalyst Series including making connections etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
17
101259
1721403
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPS PoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
9
149428
1344852
Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
15 U Rack with Width 600 mm & Depth 400 mm + 100 mm
8
18213
145704
S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
20 mm
120
122
14640
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
2 x 1.5 sq.mm
4400
43
189200
Supply, Installation, Testing & Commissioning of IP Phones along with Dual switched auto-sensing 10/100 Mbps Ethernet ports with integrated BUILT-IN PoE+ to power the device and give it a network connection, 2 line keys with dual colour LED and 2 SIP accounts, LCD graphical display, 3 XML programmable context-sensitive soft keys, 13 dedicated function keys for: MUTE, CONFERENCE, PHONEBOOK, MESSAGE, RECORD, HOME, TRANSFER, HOLD, HEADSET, MUTE, SEND/REDIAL, SPEAKERPHONE, VOL+, VOL; . Supports HD audio both on handset and full-duplex handsfree speakerphone and 3-way conference. UL & FCC/CE compliance of Approved Makes: Cisco, Alcatel, Grandstream
55
5870
322850
SITC of 1 KVA Line interactive,160-260 V,50 Hz Off-Line UPS with Isolation transformer suitable for single phase AC input and single phase AC output having enclosure degree of protection as per IS:13947 Part-I/1993/2004 complete with all protection with SMF VRLA (12V , 7AH -2nos) Batteries,Charger,Switching Device etc.
16
7550
120800
Supply Installation Testing & Commissioning of Managed Layer-3 Intelligent Ethernet Enterprise Catalyst Series Central Switch providing 24 unpopulated 1000BASE SFP with option for min 2 unpopulated SFP upgradable to 40Gbp SFP, with option for min 8 unpopulated SFP upgradable to 10Gbp SFP, 1 x Fixed AC power supply and option for RPS with following specifications: Minimum of 24 ports unpopulated SFP Supporting 1000SX, 1000 LX, 1000BX, 10G SR/LR, and 100 FX interfaces, Switch should support 8 x 10Gbps SFP+ fully activated ports additional and exclusive to above required ports; SFP+ Ports shall be enabled for 10G operation, Should have USB port for Image backup and storage, should have dedicated and Exclusive stacking ports with stack bandwidth of 40 GBPS, have Redundant Power Supply support and variable speed fan to adjust to varying weather conditions in campus, Design & Performance: Each switch should have 208 Gbps or more with non blocking architecture and Forwarding rate of 154 Mpps, Switch Should be equipped with minimum 8Gb DRAM and 16 Gb flash, Should have LED indicator for per por status , FAN, PSU and Management Status, Hardware and software configuration have for IPv6 from day one, Switching: Should have 32000 MAC Address, 4094 active Vlans, Should have Port based VLAN, MAC based VLAN, private vlan and MVR,Should have Should have 8 Hardware QOS Queues per port ,Should have MAC address tracking and notification for mac address addition , delete or movement in the Network,Should have minimu 8000 Multicast routing scale, Should support L3 routing protocols like OSPF, RIP,Switch should be upgradeable to support, with provision of retundent power supply with related IP Base Software, Switch Should be UL, EN, IEC, AS, IEEE 802.3 Certifications. All switches & related Fiber modules should be of sam make & category for seamless integration with each other. All as per pre approved by Engineer in charge. For additional technical parameters of product work refer Annexure 'A' attached with PWD Electrical BSR 2022.
2
754700
1509400
SITC of multi-port voip-fxo-fxs Gateways combines VoIP and POTS networks, should have minimum 32 VOIP Calls with VoIP Security and Built-in PBX Functionalities, up to 2000 call records, for intigration with EP PBX system of main building of MDM Hospital.
1
192650
192650
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%