Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 20,789Document Cost
₹ 2,950Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_RRVPN_455831_1Tender No
BN-3310002418Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
ERECTION OF SUB STATION STEEL STRUCTURES columns, beams lighting mast and equiopemtn structures ( excluding Circuit Breakers and Capacitors Banks ) of all types including transportation of structure members nuts & bolts, washers etc from site store to locations , their assembly, placing on foundation, fxinmg of template, with foundation bolts as required, levelling and preparing for grounding as required but excluding grouting erection after grouting and tightening & punching of nuts & bolts. ( Maximum height of structures upto 20 meters).
2
2321
4642
... More
BUS - BAR WORK
STRINGING OF 220 KV , 132 KV, 33 KV & 11KV Bus Bar of ACSR conductor, including transportation of counductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available fitting of bolted type or compression type tension hardware as made available ( compression machine shall be provided by RVPN on rent free basis ) making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor for three phases of conductors in each bus section (Per Jumper Basis)
i) Any Single Conductor
1
1165
1165
... More
BUS - BAR WORK
STRINGING OF 220 KV , 132 KV, 33 KV & 11KV Bus Bar of ACSR conductor, including transportation of counductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available fitting of bolted type or compression type tension hardware as made available ( compression machine shall be provided by RVPN on rent free basis ) making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor for three phases of conductors in each bus section (Per Jumper Basis)
i) Any Double Conductor
12
1758
21096
... More
JUMPERS OF ACSR conductor (3 nos Y type) between bus to equipment or between equipment to equiopment or between bus to bus, including transportation of conductor, disc insulatros and hardware from site stiores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections,fixing of spacers & spacer T clamps as required tightening of clamps / connectors, dressing etc for three phases (Per Jumper Basis)
i) Any Conductor
180
111
19980
... More
ERECTION OF SUB-STATION EQUIPMENTS
Erection of Current Transformer/Potential Transformer/ Capactive voltage Transformer /Series Reactor /Residual Voltage Transformer /Neutral Current Transformer with Clamps & connectors, on already erected steel structure including transport-Tation of base frame,fixing of terminal connectors,tightening of nuts & bolts etc. complete in all respect.
i) 220KV CT/PT/CVT
3
2529
7587
... More
ERECTION OF SUB-STATION EQUIPMENTS
Erection of Current Transformer/Potential Transformer/ Capactive voltage Transformer /Series Reactor /Residual Voltage Transformer /Neutral Current Transformer with Clamps & connectors, on already erected steel structure including transport-Tation of base frame,fixing of terminal connectors,tightening of nuts & bolts etc. complete in all respect.
ii) 132KV CT/PT/CVT
3
1415
4245
... More
ERECTION OF SUB-STATION EQUIPMENTS
Erection of C.T / P.T /CVT/ Series Reactor / RVT / NCT with clamps & connectors on already erected steel structure including transportation from site stores to locations, fabrication of base frme, fixing of terminal connectors, tightening of nuts & bolts etc complete in all respect.
iii) 33 KV or 11 KV CT/PT
12
532
6384
... More
Erection of Isolators (Motorised/Non Motorised) on already, erected steel structures including transportation of base frame, P.I's contacts mechanism box clamps & connectors etc from site store to locations minor fabrication as required and fixing of termnial connectors etc adjustment / aligment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of P.I.
iii) 33 KV & 11 KV
a) Without Earth Blade
8
916
7328
... More
Erection of 132KV Class EHV Transformer (tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings main & OLTC conservators, radiators, equalizing pipe line marshalling kiosk, etc. as per manufacturer’s drawing, prepare- tion of oil, oil filling dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g, Buchholz relay, MOLG, OSR, etc to marshalling kiosk, etc. but excluding testing & commissioning of transformer.
a) If electricity is available & arranged by RVPN without charges.
i) Transformer received oil filled
2
42089
84178
... More
Erection of 220KV Class EHV Transformer (Gas filled tank Already placed on foundation with wheels), including transport- Tation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, erection of cooler bank with associated Pipe line, radiators, fans, pump, main & OLTC conservators, Equalizing pipe line, marshalling kiosk, etc. as per manufacturer’s Drawing preparation of oil, oil filling, dehydration of transformer Along with cooler bank & diverter switch(filter machine oil tank & operating staff shall be provided by RVPN), electrical wiring From individual equipment, e.g. Buchholz relay, MOLG, OSR, Fans Pumps, Bushing CT’s etc to marshalling kiosk etc. but Excluding testing & commissioning of transformer.
a) If electricity is available & arrange by RVPN without charges.
1
128596
128596
... More
Erection of Control & Relay Panels complete in all respect, Including transportation from site store to control room, placingOn foundation/cable trench as per layout, interconnection between Control & Relay panels and with existing panels fixing of site/top Covers and doors earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required.
iii) Simplex Panel, DC Panel,RTCC Panel,PLCC Panel,etc.
6
632
3792
... More
Erection of Marshalling Kiosk/Line Matching Unit(LMU)/Line Matching & Distribution Unit (LMDU) complete in all respect Including transportation from site store to location, placing on Foundation/ cable trench as per layout, preparing for grouting Of foundation bolts but excluding grouting etc.
i) 220KV or 132KV Marshalling Kiosk
1
374
374
... More
Erection of Marshalling Kiosk/Line Matching Unit(LMU)/Line Matching & Distribution Unit (LMDU) complete in all respect Including transportation from site store to location, placing on Foundation/ cable trench as per layout, preparing for grouting Of foundation bolts but excluding grouting etc.
ii) 33KV or 11KV Marshalling Kiosk
2
192
384
... More
LAYING AND TERMINATION OF CABLES:
Control Cable: i) Laying of P.V.C insulated unarmoured/ armoured control cable of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placing them on cable racks/cable trays/ cable batten & dressing, including removing and re-fixing trench covers as required making necessary connections, testing, cable marking on both the terminating ends, etc. as required for all sizes from 2c x 2.5 sq.mm to 20c x 2.5 sq.mm nd 4c x 6 sq.mm.
a) Unarmoured control cable.
7000
5
35000
... More
ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required, & including cost of cable glands, for each cable gland of size
a) 19mm unarmoured control cable
40
44
1760
... More
ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc. as required, & including cost of cable glands, for each cable gland of size
c) 25mm unarmourd control cable
20
67
1340
... More
ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS : 12943 & having three metal washers and one rubber ring, inluding preparation of cable and drilling of correspomding holes in gland plates, etc. as required & including cost of cable glands for each cable gland of size
e) 32 mm Unarmoured Control Cable
20
96
1920
... More
iii) Termination of wires of cables with copper conductor using copper terminal ends ( pin or ring type as required of Dowell's or equivalent make as approved by the Engineer- In-Charge ) duly crimpede with crimping tool including making wire ends ready for crimping, ferruling & dressing of wires, etc as required , including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes.
a) 2.5 sqmm for any number of core
1800
11
19800
... More
iii) Termination of wires of cables with copper conductor using copper terminal ends ( pin or ring type as required of Dowell's or equivalent make as approved by the Engineer- In-Charge ) duly crimpede with crimping tool including making wire ends ready for crimping, ferruling & dressing of wires, etc as required , including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes
b) 4.0 sqmm for any number of core
1200
14
16800
... More
Dismantling Work
DISTRINGING of 33KV Bus Bar of ACSR conductor, including transportation of conductor,disc Insulator and tension hardware from location to site stores, cleaning and assemblyof disc insulators as required along with fitted bolted type or compression tape tension hardware as dismantled, destringing of conductors between the beams for three plates of conductors in each bus-section. (Per Jumper basis) i) Any Single Conductor
13
699
9087
... More
Dismantling of JUMPERS OF ACSR conductor ( 3 nos Y- type)between bus To equipment or between equipment to equipment or between bus, cleaning and assembly of disc insulators as required along with dismanteled of suspension hard- ware as required, for three phases. (Per Jumper basis)
i) Any Conductor
180
66
11988
... More
Dismantling of Current Transformer/Potential Transformer/ Capactive voltage Transformer /Series Reactor /Residual Voltage Transformer /Neutral Current Transformer with Clamps & connectors, from erected steel structure including transportation of dismantel terminal connectors,etc. complete in all respect.
i) 220KV CT/PT/CVT
3
1517
4552.2
... More
Dismantling of Current Transformer/Potential Transformer/ Capactive voltage Transformer /Series Reactor /Residual Voltage Transformer /Neutral Current Transformer with Clamps & connectors, from erected steel structure including transportation of dismantel terminal connectors,etc. complete in all respect.
i) 220KV CT/PT/CVT
3
849
2547
... More
Dismantling of Current Transformer/Potential Transformer/ Capactive voltage Transformer /Series Reactor /Residual Voltage Transformer /Neutral Current Transformer with Clamps & connectors, from erected steel structure including transportation of dismantel terminal connectors,etc. complete in all respect.
iii) 33KV or 11KV CT/PT
6
319
1915.2
... More
Dismantle of 220KV Class EHV Transformer Already placed on foundation with wheels, including transportation of accessories from location to site store, dismantle of HV, IV, LV & Neutral bushings, dismantle of cooler bank with associated Pipe line, radiators, fans, pump, main & OLTC conservators, pipe line, marshalling kiosk, etc. as per site requirement, dismantle electrical wiring From individual equipment, e.g. Buchholz relay, MOLG, OSR, Fans Pumps, Bushing CT’s etc to marshalling kiosk etc. but Excluding testing of transformer.
a) If electricity is available & arranged by RVPN without charges.
i) Transformer
1
77157
77157.6
... More
Dismantle of 132KV Class EHV Transformer (tank already placed on foundation with wheels), including transportation of accessories from location to site store, dismantle of HV, IV, LV & Neutral bushings main & OLTC conservators, radiators, equalizing pipe line marshalling kiosk, etc. as per requirement of sie condition, dismental electrical wiring from individual equipment, e.g, Buchholz relay, MOLG, OSR, etc to marshalling kiosk, etc. but excluding testing & decommissioning of transformer.
a) If electricity is available & arranged by RVPN without charges. i) Transformer received oil filled
2
25253
50506.8
... More
Dismantlong of Isolators (Moterised/Non Moterised) on already erected steel structure Including transportation of base frame,P contacts mechanism Box clamps & connectors etc from location to site store as required, and dismantle of terminal connectors and dismantle of PI.
ii) 33KV & 11KV
a) Without Earth Blade
6
549
3297.6
... More
Services for loading or unloading or shifting on platform or other location in yard of transformer up to 50 MVA.
2
25841
51682
... More
Services for loading or unloading or shifting on platform or other location in yard of transformer 100 to 160 MVA.
1
38761
38761
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%