If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan Rajya Vidyut Prasaran Nigam Limited - RVPN Tender

Works
Eprocure
Opening Date26 Nov 2024
Closing Soon26 Dec 2024
Tender Amount₹ 24,63,569 
Notes
Download

Costs

  • EMD

    ₹ 49,300
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 590

Summary

Work Of Laying Of Earth Mesh Earthng Of Sub Station Structure And Equipment Erection Of Steel Structure And Equipment Stringing Of Bus Bar And Earth Wires Jumpers Installation Of Control Panel Cable Layingandterminationofcable Etcat 132 Kvgss Kelwara

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Work of Laying of Earth Mesh Earthng of Sub Station Structure and Equipment Erection of Steel Structure and equipment Stringing of Bus Bar and Earth wires Jumpers Installation of Control panel cable laying and termination of cable etcat 132 KV GSS KELWARA
AS PER TENDER DOCUMENTS
AS PER NIB DOCUMENTS
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b) in case diesel generator is arranged by the contractor at his own cost. ii) Hard rock (with blasting subject to permission or without blasting )

1500

59

88500

... More
Placing of earth electrode of 25/28mm dia M S Rod of length 7.50meters (approx) to a depth of 8.00 meters from the top level of foundation including drilling of 200mm dia earth pit having a throughout bore of 200 mm dia to a depth of 8.00 meters from the top level of the foundation in all types of rocks by DTH System and overburden including back filling of pit with Bentonite slurry (with cost of Bentonite slurry) including its preparation transportation of of MS Rod and Bentonite from site store to location cutting of MS Rod to desired length welding of earth electrode to earth Mesh of M S Rod as per drawing application of bitumen compound and covering with bitumen impregnated tape on all welded joints (M S Rod of above sizes & M.S Flat as required shall be made available by RVPN). (i) in case electricity is made available by RVPN without charges

65

11230

729950

... More
ERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members,nuts & bolts, washers, etc. from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. ( Maximum height of structures up to 20 meters)

100

2321

232100

... More
Bus-Bar Work STRINGING of 220 KV, 132 KV, 33 KV & 11KV Bus Bar of ACSR & Tarantulla conductor, including transportation of conductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available, making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phases of conductors in each bus-section.(Per jumper basis i) Any Single Conductor

12

1165

13980

... More
ii) Any Double Conductor

9

1758

15822

... More
JUMPERS of any conductor (3 nos. Y- type) between bus to equipment, or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps 1connectors, dressing, etc., for three phases. (Per jumper basis) i) Any Conductor

300

111

33300

... More
STRINGING of Earth wire ( size 7 13.15 mm or 7/4.00 mm ), including transportation of Each 292.00 earthwire, tension hardwares, etc., from site store to locations, laying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available, making up at one end, stringing of earthwire between structure peaks with specified sag and tension, jumpering and connecting earth bonds, for single earthwire .

60

292

17520

... More
ERECTION OF SUB STATION EQUIPMENTS i) Erection of 33/0.4 KV or 11/0.4 KV Station transformer up to 500 KVA on existing masonary Each 3967.00 platform including transportation of transformer & accessories from site store to location, erection of Horn Gap fuse set, jumpering from isolator to Horn Gap to transformer.

1

3967

3967

... More
Erection of Current Transformer / Potential Transformer / Capacitive voltage Transformer 1 Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc., complete in all respects. ii) 132 KV CT / PT / CVT

33

1415

46695

... More
iii) 33 KV or 11 KV CT / PT

27

532

14364

... More
Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter, etc. from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc., complete in all respect ii) 132 KV

12

1422

17064

... More
iii) 33 KV or 11 KV

18

317

5706

... More
Erection of Isolators(Motorised/Non motorised) on already erected steel structure including transportation of base frame, P. I.'s, contacts, mechanism box, clamps & connectors, etc. from site store to locations, minor fabrication as required, and fixing of terminal connectors, etc., adjustment! alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including erection of PI ii) 132 KV a) Without Earth Blade

18

2596

46728

... More
b) With single Earth Blade

3

3045

9135

... More
iii) 33 KV & 11 KV a) Without Earth Blade

20

916

18320

... More
b) With Single Earth Blade

5

1364

6820

... More
Erection of Wave trap on already erected structure beam, including transportation of wave trap, disc insulators, hardware, clamps and connectors, etc. from site store to locations, cleaning & assembly of disc insulators alongwith fitting of suspension arrangement and erection, fixing of terminal connectors, etc. ii) 132 KV

3

599

1797

... More
Erection of 220 KV or 132 KV Circuit Breakers, including transportation of equipment, structure members, nuts & bolts, clamps & connectors, accessories etc. from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support columns / poles, mechanism box / control cubicle, and other accessories as per manufacturer's drawings, fitting of SF 6 gas pipeline, fabrication of air / oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB, for all types of operating mechanism, as required. ii)132 KV

5

15223

76115

... More
Erection of 33 KV or 11 KV Circuit Breakers including transportation of equipment, structure members, nuts & bolts, clamps & connectors, etc. from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of poles, mechanism box, etc. on support structure as per manufacturer's drawings, fitting of terminal connectors, etc. but excluding commissioning of CB. i) 33 KV or 11KV Outdoor Type ( VCB / SF 6 )

7

7404

51828

... More
Erection of 132 KV class EHV Transformer( tank already placed on foundation with weels) including transportation of accessaries from site store to location, erection of HV , LV, IV & Neutral bushing,main & OLTC conservators ,radiators equlizing pipe line,marshaling Kiosk etc. as per manufacturer's drawing, prepration of oil,oil filling,dehydration of Transformer ( filter machine,oil tank,& operating staff shall be provided by RVPN ) electrical wiring from individual equipment e.g. Buchholz relay,MOLG,OSR, etc to marshaling kiosk etc but excluding testing & commissioning of Transformer. a) If electricity is available & arranged by RVPN without charges. i) Transformers received oil filled

1

42089

42089

... More
Erection of Control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation I cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side I top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel, as required ii) Duplex Panel

5

1265

6325

... More
iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc.

7

632

4424

... More
iv) LT Panel

1

1739

1739

... More
Erection of Marshalling Kiosk! Line Matching Unit (LMU) I Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation I cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting, etc. i) 220 KV or 132 KV Marshelling Kiosk

5

374

1870

... More
ii) 33 KV or 11 KV Marshelling Kiosk

7

192

1344

... More
Erection of Battery Charger complete in all respect including transportation from site store to location, placing on foundation I cable trench as per layout, etc. i) 110 Volt DC, 200 AH

1

1265

1265

... More
iii) 48 Volt DC, 600 / 400 / 200 AH

1

1265

1265

... More
Battery Set Assembly, erection and commissioning of Maintenance Free VRLA type Battery Set including transportation of celis, battery stand, nuts & bolts, etc. from site store to battery room, assembly of stand, placing the cells on stand, making their interconnection, initial charging, discharging and final charging as per procedure recommended by battery manufacturer. a) If electricity is available & arranged by RVPN without charges. i) 110 Volt DC, 200 AH

1

24621

24621

... More
iii) 48 Volt DC, 600 / 400 / 200 AH

1

22875

22875

... More
Laying and termination of cable i) Laying of P. V. C. insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placinq them on cable racks / cable trays / cable batten & dressing, including removing and refixing trench covers as required, making necessary connections, testing, cable marking on both the terminating ends, etc., as required for all sizes from 2c x 2.5 sq. mm. to 20c x 2.5 sq. mm, 4c x 4 sq. mm. and 4c x 6 sq. mm. (a) Unarmoured control cables

15000

5

75000

... More
ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required & including cost of cable glands, for each cable gland of size. (a) 19 sq. mm unarmoured control cables

200

44

8800

... More
(c) 25 sq. mm unarmoured control cables

250

67

16750

... More
(e) 32 sq. mm unarmoured control cables

50

96

4800

... More
iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires, etc., as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes a) 2.5 Sqmm for any number of core

1500

11

16500

... More
b) 4 Sqmm for any number of cor

1000

14

14000

... More
L.T. Power Cables i) Laying of P. V. C. insulated and P. V. C. sheathed armoured/unarmoured L. T. power cable of 1.1 KV grade with aluminium conductor as per IS: 1255 in ground I cable trench I wall I surface including transportation of cable drums from site store to locations and excavation of 30 cm x 75 cm size trenches, providing 25 mm thick under layer of sand & 2nd class brick covering & refilling earth in remaining portion, fixing as per approved I available spacing by means of M. S. U-clamps, etc. as per specification as required, including making necessary connections & testing, etc. as required, of the following size d) 3 ½ core × 300sq. mm.

300

53

15900

... More
ii) Fixing of power cables in position with single compression, heavy duty nickel plated brass cable glands as per IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plate, etc., including cost of cable gland if required, for each end of cable of size. g) 75 I 76 mm. for 3 Yo core x 300 sq. mm. cable with material

1

442

442

... More
iii) Termination of wires of cables with aluminium conductor using ISI marked tubular aluminium terminal ends as per IS:8309 duly crimped with crimping tool, including making cable ends ready for crimping and providing insulation tape with colour code, dressing of wires, etc., including cost of terminal ends if required, for each end of cable ( 4 nos. per end ) for the following size of cables g) 3.5 core x 300 sq. mm cable with material

2

820

1640

... More
Providing and laying in position specifed grade of cement concrete for all RCC Structural elements up to plinth level including curing,compaction,finishing with rendering in cement sand mortar 1:3(1 cement:3coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering , shuttering and reinforcement. M20 grade Nominal Mix/Design Mix (The rate are as per PWD BSR 2014- Jaipur)

20

4378

87560



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.