Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 5,70,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_RRVPN_139828_1Bid Award Id
ViewTender No
CONT-I/2018-19/BN-9018001824Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(i) Normal soil
1500
-
259
... More
(ii) Murram/Black cotton/Hard Soil/Dense soil.
2800
-
548
... More
(iii) Soft rock/disintegrated rock.
2000
-
605
... More
(iv) Hard rock (blasting prohibitted)
400
-
1383
... More
(iv) Hard rock (with blasting)
200
-
1269
... More
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming and watering as per specification.
(A) 132 KV single Circuit Tower upto +6m.extension.
-
-
-
... More
(I) Tangent Tower (TTA)
115
-
2564
... More
(ii) Small angle Tower (TTB)
20
-
2936
... More
(iii) Medium angle Tower (TTC)
10
-
4290
... More
(iv) Large angle cum dead end Tower (TTD)
12
-
4436
... More
F(a) 220 KV Double Circuit Tower upto +6m.extension.
-
-
-
... More
(i) Large angle cum dead end Tower (TTD)
2
-
7458
... More
(H) 220KV Double Circuit Special Tower + 9 Mtr. Ext.(TTA)
2
-
7458
... More
Concreting:- Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
-
-
-
... More
(i) 1:4:8 Mix
10
-
7575
... More
(i) 1:3:6 Mix
160
-
8525
... More
(ii) 1:2:4 Mix
250
-
8784
... More
(iii) 1:1:5:3 Mix
700
-
10715
... More
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and Drawings including material
50
-
61496
... More
EARTHING:
-
-
-
... More
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all
types of soil.
20
-
1568
... More
(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.
(i)each set by laying 4 wires each 15m long at a depth of 600mm
141
-
1960
... More
ERECTION OF TOWERS:
Erection of super structures including D-shackles, ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
(A)132 KV Single Circuit Tower
-
-
-
... More
(I) Tangent Tower (TTA)
115
-
9504
... More
(ii) Small angle Tower (TTB)
20
-
11176
... More
(iii) Medium angle Tower (TTC)
10
-
11925
... More
(iv) Large angle cum dead end Tower (TTD)
12
-
16763
... More
(F)220KV Double Circuit Tower .
-
-
-
... More
(iv) Large angle cum dead end Tower (TTD)
2
-
45391
... More
(H)220KV Double Circuit Special Tower for span up to 550m
-
-
-
... More
H(i) 220KV Double Circuit Special Tower Normal Structure(TTA)
2
-
45565
... More
H(iii) 220KV Double Circuit Special Tower + 9 Mtr Ext. to Normal Structure
2
-
22839
... More
Erection of 3 meters extension including tack welding of all bolts & nuts and application of zinc rich paint (A) 132 KV Single Circuit Tower
-
-
-
... More
(I) Tangent Tower (TTA)
10
-
1584
... More
(ii) Small angle Tower (TTB)
4
-
2219
... More
(iii) Medium angle Tower (TTC)
2
-
2621
... More
(iv) Large angle cum dead end Tower (TTD)
3
-
3195
... More
Erection of 6 meters extension including tack welding of all bolts & nuts and application of zinc rich paint (A) 132 KV Single Circuit Tower
-
-
-
... More
(I) Tangent Tower (TTA)
7
-
3169
... More
(ii) Small angle Tower (TTB)
2
-
4176
... More
(iii) Medium Angle Tower (TTC)
2
-
5414
... More
(iv) Large angle cum dead end Tower (TTD)
2
-
6306
... More
( F) 220 kv Double Circuit Tower (iv) Large angle cum dead end Tower (TTD)
2
-
10888
... More
ERECTION OF SUB STATION STRUCTURE
-
-
-
... More
Erection of substation structures including leveling, setting of stub & Tighting, Punching of Nuts& Bolts and tack welding upto beam level as per specification.
6
-
5299
... More
CONDUCTOR STRINGING:- (A) Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(ii) 3 conductor for S/C Line
50
-
39660
... More
Stringing of Earth wire:- (A) Stringing of galvanised steel stranded wire including laying,jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc.
(i) One No. 7/3.15 mm galvanised wire
50
-
6713
... More
Rivetment of Tower
-
-
-
... More
(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
15
-
2263
... More
(B ) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
30
-
2167
... More
(C )Random rubble dry stone pitching including preparing surface etc. complete with stone weighing 30 to 40 kg each and raised & cut pointing in cement sand mortar 1:3, curing etc.
20
-
780
... More
(D )Cement concrete coping grade 1:2:4(1cement:2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 50mm thick with 20mm thick nominal size aggregate
20
-
348
... More
(E) Brick masonary in foundation & plinth with bricks of class designation 75 in cement mortar 1:5 (1 cement : 5 coarse sand)
30
-
2786
... More
(F) Brick on edge flooring with bricks of class designation 75 including pointing in cement mortar (1:3) complete laid on 12mm thick bed of cement sand mortar 1:6.
15
-
356
Evaluation Notes How It Works ?