Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 12,560Document Cost
₹ 590Tender Fee
₹ 590
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRVPN_388296_1Bid Award Id
ViewTender No
NIT 29/2023-24Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
B-69/6.2.2+6.3.4 Random Rubble stone masonry with hard stone in Super Structure above Plinth Level and up to floor V level upto 30 cm thick walls in CM 1:6 ( 1 cement : 6 coarse sand)
17
62305
3665
B-4/4.1 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
7
34538
4934
B-59/4.2 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement, 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and strut etc. M20 grade Nominal Mix / Design Mix
3
16827
5609
B-55/3.2.2 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M15 grade Nominal Mix 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
1.5
7668
5112
(B-4/4.9) Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
25
3925
157
B-61/4.10.3 Centring & Shuttering with plywood or steel sheets including strutting propping bracing both ways with steel props and removal of formwork for up to floor five level for: Columns, pillars, posts and struts etc.
31
11625
375
B-3/3.8 Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification :
20
7340
367
B-98/9.1+9.1.1 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.
912
72230
79.2
B-98/9.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work , including cutting, hoisting (height up to 10 m), fixing In position and applying a priming coat of approved steel primer all complete:
660
53460
81
B-12/12.43.1 Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision :New Work
53
6519
123
B-12/12.46.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
46
3174
69
B-4/4.13.3 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)
758
58366
77
(R-15/4.1.A(ii)) Granular sub base with well graded material (Table 400-1). By Mix in place method: Construction of granular sub base by providing well graded material, spreading in uniform layers with Tractor mount grader and prepare surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density complete as per MoRTH specification Clause 401: For Grading-II material.
205
99015
483
B/9.31 150cm high fencing with angle iron 50x50x6mm. placed at every 3Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 5 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete.
18
9216
512
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix. (B/14.2.1)
10
6370
637
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar. (B/14.9.2)
15
9615
641
(R-37/10.4.(ii)) Providing and erecting direction and place identification retro reflectorised sign as per IRC:67 made of high intensity grade sheeting exclusive of lettering, border & signs fixed over aluminium sheeting, 2mm thick fixed on a mild steel angle iron frame 50mmX50mmX6mm supported on mild steel angle iron post 75X75X6mm upto the top of sign board, length of post from bottom of sign board is 2.85m upto foundation level post duly painted in black and white synthetic enamel alternate ship 30cm wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cmX45cmX60cm, 60cm below ground level as per approved drawing & as per MORTH specifications clause 801 Double angle post 150cmX120cm
1
10787
10787
(R-29/7.4.2) (Based on PWD Road BSR Alwar 2019) Providing & fixing letters/boarders from reflective tape of approved quality in standard width of MORTH specifications clause 800. providing and fixing letters (100mm wide)
2200
6600
3
(E-18.10.1) Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with sand blast reflector. The System level Luminous efficacy ≥ 100 Lumen/W. SMD LEDs is to be used, System CRI70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency 85%, PF0.9, THD10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current 750mA. Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Minimum lumen output 2500 lm Post top Luminarie.
3
15225
5075