Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 60,964Document Cost
₹ 2,950Tender Fee
₹ 590
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRVPN_430233_1Bid Award Id
ViewTender No
TN-12/2024-25Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Placing of earth electrode of 25 / 28mm dia. M.S. Rod of length 7.50 mtrs (approx.) to a depth of 8.00 metres from the top level of foundations, including drilling of 200 mm dia earth pit having a throughout bore of 200 mm dia to a depth of 8.00 metres from the top level of foundations, in all types of rocks by DTH system and overburden, including back filling of pit with Bentonite slurry (with cost of Bentonite slurry), including its perparation, transportation of M.S. Rod and Bentonite from site store to location, cutting of M.S. Rod to desire length, welding of earth electrode to earth mesh of M.S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).a) In case electricity is made available by RVPN without charges.
10
11230
112300
... More
ERECTION OF SUB-STATION STEEL STRUCTURES columns, beams, lighting mast and equipment structures (excluding Circuit Breakers and Capacitor Banks) of all types including transportation of structure members, nuts & bolts, washers etc from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. (Maximum height of structures up to 20 metres)
140
2321
324940
... More
STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available between the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) i) Any Single Conductor
27
1165
31455
... More
STRINGING of 220KV, 132KV, 33KV & 11KV Bus Bar of ACSR & Tarantulla conductor including transportation of conductor, disc insulator & tension hardware from site store to location, laying & cutting required length of conductor, cleaning & assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available between the beams with specified sag and tension, also equilising sag and fitting spacers and spacer T-clamps for twin conductor for three phase of conductors in each sub-section.(Per jumper basis) i) Any Double Conductor
27
1758
47466
... More
JUMPERS of ACSR conductor (3 nos. Y-type) between bus to equipment or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning & assembly of disc insulators as required along with fitting of suspension hardware and erection as required length of conductor, making connections, fixing of spacers & spacer T-clampsas required, tightening of clamps / connectors, dressing etc., for three phases.(Per jumper basis)
575
111
63825
... More
STRINGING of earth wire (size 7/3.15 mm or 7/4.00 mm) including transportation of earth wire, tension hardwares etc from site store to locations, laying and cutting required length of earth wire, fitting of bolted type or compression type hardware as made available (compression machine shall be provided by RVPN on rent free basis) making up at one end, stringing of earthwire between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earthwire.
75
292
21900
... More
i) Erection of 33/0.4 KV or 11/0.4 KV station transformer up to 500 KVA on existing masonary platform including transportation of transformer & accessoreis from site store to location, erection of Horn Gap fuse set, jumpering from isolator to Horn Gap to transformer.
1
3967
3967
... More
i) Erection of 33/0.4 KV or 11/0.4 KV station transformer up to 500 KVA on existing masonary platform including transportation of transformer & accessoreis from site store to location, erection of Horn Gap fuse set, jumpering from isolator to Horn Gap to transformer.ii) Filteration of the transformer, if required (Additional cost)
1
1323
1323
... More
Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. ii) 132 KV CT / PT / CVT
24
1415
33960
... More
Erection of Current Transformer / Potential Transformer / Capacitive Voltage Transformer / Series Reactor / Residual Voltage Transformer / Neutral Current Transformer with clamps & connectors on already erected steel structure including transportation from site store to locations, fabrication of base frame, fixing of terminal connectors, tightening of nuts & bolts etc, complete in all respects. iii) 33 KV or 11 KV CT / PT
27
532
14364
... More
Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects. ii) 132 KV
9
1422
12798
... More
Erection of Lightening Arrestor on already erected steel structure including transportation of Lightening Arrestor, clamps & connectors, surge counter etc from site store to locations, fabrication of base frame, fixing of terminal connectors, surge counter, tightening of nuts & bolts etc, complete in all respects. 33 KV or 11 kV
18
317
5706
... More
Erection of 132 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. a) Without Earth Blade a) Without Earth Blade
12
2596
31152
... More
Erection of 132 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. b) With Single Earth Blade
2
3045
6090
... More
Erection of 132 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. c) Fixing of Single Earth Blade
2
449
898
... More
Erection of 33 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. a) Without Earth Blade
20
916
18320
... More
Erection of 33 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI. b) With Single Earth Bladec
5
1364
6820
... More
Erection of 33 KV Isolators (Motorised/ Non motorised) on already erected steel structure including transportation of base frame, P I's contacts, mechanism box, clamps & connectors etc from site store to locations, minor fabrication as required and fixing of terminal connectors etc, adjustment / alignment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI.) Fixing of Single Earth Blade
5
448
2240
... More
Erection of 132 kV Wave trap on already erected structure beam including transportation of wave trap, disc insulators, hardware, clamps & connectors etc from site store to locations, cleaning & assembly of disc insulators alongwith fitting of suspension arrangement and erection, fixing of terminal connectors etc.
2
599
1198
... More
Erection of 220 KV or 132 KV Circuit Breaker including transportation of equipments, structure members, nuts & bolts, clamps & connectors etc from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of support coulmns / poles, mechanism box / control cubicle, and other accessories as per manufacturer's drawings, fitting of SF6 gas pipeline, fabrication of air / oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required, but excluding commissioning of CB for all types of operating mechanism as required. ii) 132 KV
4
15223
60892
... More
Erection of 33 KV or 11 KV Circuit Breaker including transportation of equipments, structure members, nuts & bolts, clamps & connectors etc from site store to locations, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting, assembly / placing of poles, mechanism box etc on support structure as per manufacturer's drawings, fitting of terminal connectors as required, but excluding commissioning of CB. i) 33 KV or 11 KV outdoor type (VCB / SF6)
7
7404
51828
... More
Erection of 132 kV Post Insulators on already erected structure including transportation of P. I. 's nuts & bolts, clamps & connectors etc from site store to locations, fabrication of base frame, assembly if required, fixing of clamps etc.
9
665
5985
... More
Erection of 33 kV or 11 kV Post Insulators on already erected structure including transportation of P. I. 's nuts & bolts, clamps & connectors etc from site store to locations, fabrication of base frame, assembly if required, fixing of clamps etc.
9
75
675
... More
Erection of 132 KV Class EHV Transformer (tank already placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings, main & OLTC conservators, radiators, equilizing pipe line, marshalling kisok etc as per manufacturer's drawing, preparation of oil, oil filling, dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz Relay, MOLG, OSR etc to marshalling kiosk etc but excluding testing & commissioning of transformer.(a) If electricity is available & arranged by RVPN without charges. i) Transformer received Oil filled
1
42089
42089
... More
ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. ii) Duplex Panel
4
1265
5060
... More
ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc
8
632
5056
... More
ERECTION OF CONTROL & RELAY PANALS complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel as required. iv) LT Panel
1
1739
1739
... More
ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. i) 220 KV or 132 KV Marshlling Kiosk
7
374
2618
... More
ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. ii) 33 KV or 11 KV Marshlling Kiosk
6
192
1152
... More
ERECTION OF MARSHALLING KIOSK / Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc. iii) PLCC LMU / LMDU
2
432
864
... More
ERECTION OF BATTERY CHARGER complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout etc. ii) 110 Volt DC, 200 AH
1
1265
1265
... More
ERECTION OF BATTERY CHARGER complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout etc. iiI) 48 Volt DC, 600/400/200 AH
1
1265
1265
... More
Assembly, erection and commissioning of Lead Acid Battery Set including transportation of cells, battery stand, nuts & bolts etc from site store to battery room, assembly of wooden stand, placing the cells on stand, making their interconnection, filling of elctrolyte, giving two cycle of charge and discharge after initial charging as per procedure recommended by battery manufacturer.(a) If electricity is available & arranged by RVPN without charges iI) 110 Volt DC, 200 AH
1
24621
24621
... More
Assembly, erection and commissioning of Lead Acid Battery Set including transportation of cells, battery stand, nuts & bolts etc from site store to battery room, assembly of wooden stand, placing the cells on stand, making their interconnection, filling of elctrolyte, giving two cycle of charge and discharge after initial charging as per procedure recommended by battery manufacturer.(a) If electricity is available & arranged by RVPN without charges iv) Additional cycle of charge & Discharge, if required
1
4576
4576
... More
Assembly, erection and commissioning of Maintenance free VRLA type Battery Set including transportation of cells, battery stand, nuts & bolts etc from site store to battery room, assembly of stand, placing the cells on stand, making their interconnection, initial charging, discharging and final charging as per procedure recommended by battery manufacturer.(a) If electricity is available & arranged by RVPN without charges. iiI) 48 Volt DC, 600/400/200 AH
1
6613
6613
... More
Assembly, erection and commissioning of Maintenance free VRLA type Battery Set including transportation of cells, battery stand, nuts & bolts etc from site store to battery room, assembly of stand, placing the cells on stand, making their interconnection, initial charging, discharging and final charging as per procedure recommended by battery manufacturer.(a) If electricity is available & arranged by RVPN without charges. v) Additional cycle of charge & Discharge, if required
1
4576
4576
... More
i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable treches, cutting of required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trech covers as required , making necessary connections, testing, cable marking on both the terminating ends etc as required for all sizes from 2C x 2.5 sq. mm. to 20C x 2.5 sq. mm, 4C x 4 sq. mm and 4C x 6 sq. mm. a) Unarmoured control cable
21500
5
107500
... More
i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site store to locations, laying in cable treches, cutting of required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trech covers as required , making necessary connections, testing, cable marking on both the terminating ends etc as required for all sizes from 2C x 2.5 sq. mm. to 20C x 2.5 sq. mm, 4C x 4 sq. mm and 4C x 6 sq. mm. b) Armoured control cable
500
6
3000
... More
ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size a) 19 mm unarmoured control cable
1000
44
44000
... More
ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size c) 25 mm unarmoured control cable
250
67
16750
... More
ii) Fixing of control cable in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc as required & including cost of cable glands for each cable gland size e) 32 mm unarmoured control cable
500
96
48000
... More
iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes.a) 2.5 Sqmm for any number of core
12000
11
132000
... More
iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires etc as required including cost of terminal ends for all wires for each cable at both ends for cables of the following sizesb) 4 Sqmm for any number of core
4500
14
63000
... More
i) Laying of PVC insulated unarmoured / armoured L.T. power cables of 1.1 KV grade with aluminium conductor as per IS:1255 in ground / cable trench / wall / surface including transportation of cable drums from site store to locations and excavation of 30 cm x 75 cm size trenches, providing 25 mm thick under layer of sand & 2nd class brick covering & refilling earth in remaining portion, fixing as per approved / available spacing by means of M.S.U - clamps etc as per specification as required including making necessary connections & testings etc as required of the following sizes. d) 3.5c x 300 sq. mm.
250
53
13250
... More
ii) Fixing of power cables in position with single compression, heavy duty nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc, including cost of cable gland if required, for each end of cable of size. g) 75 / 76 mm for 3.5c x 300 sq. mm cable with material
2
442
884
... More
ii) Fixing of power cables in position with single compression, heavy duty nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates etc, including cost of cable gland if required, for each end of cable of size. h) 75 / 76 mm for 3.5c x 300 sq. mm cable without material
2
124
248
... More
iii) Termination of wires of cables with aluminium conductor using ISI marked tubular aluminium terminal ends as per IS:8309 duly crimped with crimping tool, including making cable ends ready for crimping and providing insulation tape with colour code, dressing of wires etc, including cost of terminal ends if required for each end of cable (4 nos. per end) for the following size of cables. g) 3.5c x 300 sq. mm cable with material
4
820
3280
... More
iii) Termination of wires of cables with aluminium conductor using ISI marked tubular aluminium terminal ends as per IS:8309 duly crimped with crimping tool, including making cable ends ready for crimping and providing insulation tape with colour code, dressing of wires etc, including cost of terminal ends if required for each end of cable (4 nos. per end) for the following size of cables. g) 3.5c x 300 sq. mm cable with material h) 3.5c x 300 sq. mm cable without material
4
384
1536
... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy =125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min =4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. (E 18.11.9) High Power LED Flood Light Minimum lumen output 25000 lm
25
13300
332500
... More
Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. All as per pre approved by Engineer in charge. (Size- 200mm X 200mm X 122mm) (E 18.17.3)
8
2854
22832
... More
Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. {Four pole Isolator, 30/40 Amps. rating} (E 6.2.3.1)
8
780
6240
... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. {single pole MCB 6 to 32 Amps.} (E 6.1.1.2).
25
187
4675
... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. (metal door single phase) 4 way (E 6.10.1.1).
25
1795
44875
... More
Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect.All as per pre approved by Engineer in charge. (B Class, Size- 32MM Dia) (E 21.12.1)
25
513
12825
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 2X6 Sq. mm Armoured (E 11.2.2.1).
1000
128
128000
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 4X4.0 Sq. mm Armoured (E 11.2.1.3)
500
139
69500
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 4X4.0 Sq. mm Armoured (E 11.2.1.3)
500
166
83000
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size 4X16 Sq. mm Armoured (E 11.2.4.3)
250
232
58000
... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity 99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. 2X2.5 Sq. mm Unarmoured (E 11.3.2.1)
500
120
60000
... More
INSTALLATION OF FODP 48F
1
25750
25750
... More
INSTALLATION OF 48F FOAC (DWSM)
1
46350
46350
... More
INSTALLATION OF HARDWARE SET FOR 48F FOAC
1
2575
2575
Evaluation Notes How It Works ?