Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan Rajya Vidyut Prasaran Nigam Limited - RVPN Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date20 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 36,72,236 
Notes
Download

Costs

  • EMD

    ₹ 73,445
  • Document Cost

    ₹ 2,950
  • Tender Fee

    ₹ 590

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of 220 KV GSS, RVPN, Chainpura Chhota on labour rate contract basis
BoQ for Construction of 220 KV GSS, RVPN, Chainpura Chhota on labour rate contract basis
Construction of 220 KV GSS, RVPN, Chainpura Chhota on labour rate contract basis
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(i) Any soil, soft rock other than hard rock

8000

242608

25.7

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

1000

63720

54

... More
Laying of erthing risers of 50 x 6mm /50X10 mm /50X12 mm. Size M.S. Flat at a depth of 0.80 metre from top level of foundations, including excavation of trench of requiored depth & backfilling of the same, transportation of M.S. Flat from site store to locations, preparation of risers, bending as per requirement (after heating if necessary), fixing on and welding / bolting to equipment / structure & peaks of structures, laying in the trench, welding to the earth mesh of M.S. Rod as per drawing , including welding of extra length of M.S. Flat if required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surfaces of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 meter below top level of foundations(M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN).

-

-

-

... More
(a) In case electricity is made available by RVPN without charges.

-

-

-

... More
(i) Any soil, soft rock other than hard rock

7000

234584

28.4

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

1000

69620

59

... More
(i)Placing / driving of earth electrode of 25/28 mm dia. M.S. Rod of length 3.30 metres (approx.) to a depth of 3.80 meters from the top level of foundations, including excavation of pit as required & back filling of the same, transportation of M.S. Rod from site store to locations, cutting of M.S. Rod to desired length, preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M.S. Rod as per drawing , application of bitumen compound and covering with bitumen impregnated tape on all welded joints , for the type of soil prevalent at 3.80 meter below top level of foundation (M.S. Rod of above sizes & M.S. Flat as required shall be made available by RVPN)

-

-

-

... More
(a) In case electricity is made available by RVPN without charges.

-

-

-

... More
(i) Any soil, soft rock other than hard rock

180

58006

273.1

... More
(ii) Hard rock (with blasting subject to permission or without blasting)

50

54988

932

... More
ERECTION OF SUB-STATION STEEL STRUCTURES columns , beams, lighting mast & equipment structures (excluding Circuit breakers & Capacitor banks) of all types including transportation of structure members, nuts & bolts, washers etc. from site store to locations, their assembly, placing on foundation, fixing of template, with foundation bolts as required , levelling & preparing for grouting as required, but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. (Maximum height of structures up to 20 meters)

320

876409

2321

... More
BUS-BAR WORK

-

-

-

... More
Stringing of 220 KV, 132 KV, 33KV, 11KV busbar of ACSR conductor , including transportation of conductor, disc insulators and tenssion hardware from site store to location , laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available (compression machine shall be provided by RVPN on rent free basis), making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T- clamps for twin conductor, for three phases of conductors in each bus- section.

-

-

-

... More
i) Any Single Conductor

13

17871

1165

... More
ii) Any Double Conductor

23

47712

1758

... More
Jumpers of ACSR conductor (three nos. Y-type) between bus to equipment, or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site store to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps / connectors, dressing, etc.for three phases. (per jumper basis)

-

-

-

... More
I) Any Conductor

600

78588

111

... More
Stringing of earth wire (size 7/3.15 mm or 7/4.00 mm), including transportation of earth wire , tenssion hardware etc. from site store to locations, laying and cutting required length of earth wire, fitting of bolted type or compression type hardware as made available (compression machine shall be provided by RVPN on rent free basis), making up at one end , stringing of earthwire between structure peaks with specified sag and tension, jumpering and connecting earth bonds , for single earth wire.

100

34456

292

... More
ERECTION OF SUB-STATION EQUIPMENTS

-

-

-

... More
i) Erection of 33/0.4KV or 11/0.4KV Station transformer up to 500 KVA on existing masonry platform including transportation of transformer & accessories from site store to location, erection of Horn Gap fuse set, jumpering from isolator to Horn Gap to transformer.

1

4681

3967

... More
Erection of current transformer /Potential transformer /Capacitive voltege Transformer/Series reactor/Residuel voltage Transformer /Neutral Current Transformer with clamps & connectors ,On already erected steel structure including transportation from site store to locations, febrication of base frame,fixing of terminal connectors, tightening of nuts & bolts etc. complete in all respects.

-

-

-

... More
(i) 220 KV CT/PT/CVT

39

116384

2529

... More
(ii)132 KV CT/PT/CVT

51

85154

1415

... More
(iiI)33/11 KV CT/PT/CVT

30

18832

532

... More
Erection of Lightning Arrestor on already erected steel structure including transportation of LA , clamps and connectros, surge counter etc. from site store to locations, fabrication of base frame , fixing of terminal connectors, surge counter, tighting of nuts & bolts etc. complete in all respect.

-

-

-

... More
(i) 220 KV

15

35329

1996

... More
(ii) 132 KV

24

40271

1422

... More
(iiI) 33 KV OR 11 KV

21

7855

317

... More
Erection of isolators (Motorised/Non motorised) on already erected steel structure including transportation of base frame, PI's, contects, mechnism box, clamps and conectors etc. from site store to locations, minor fabrication as required and fixing of terminal connectors etc., adjustment / alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including of erection of PI

-

-

-

... More
i)220 KV

-

-

-

... More
(a) With Out Earth Blade

14

72688

4400

... More
(b) With Single Earth Blade

4

23123

4899

... More
(c) With Double Earth Blade

2

13114

5557

... More
(f) Tandem

6

34684

4899

... More
ii) 132 KV

-

-

-

... More
a) With out Earth blade

23

70455

2596

... More
b) With Single earth Blade

6

21558

3045

... More
iii) 33 KV & 11 kKV

-

-

-

... More
a) With out Earth blade

22

23779

916

... More
b) With Single earth Blade

6

9657

1364

... More
Erection of wave trap on already erected beam, including transportation of wave trap, disc insulators, hardware, clamps and connectors, etc. from site store to location , cleaning & assembling of disc insulators alongwith fitting of suspension arrangement and erection, fixing of terminal connectors, etc.

-

-

-

... More
i) 220 KV

8

7618

807

... More
ii) 132 KV

6

4240

599

... More
Erection of 220 KV or 132 KV or 33 KV Circuit Breakers,including transportation of equipment ,structure members nuts & bolts ,clamps & connectors ,accessories etc. from site store to locations ,assembly of support structure , their placing of foundation, levelling & preparingfor grounting as required , but excluding grouting, assembly / placing of support columns /poles,mechanism box /control cabicle and other accessories as per manufecturer's drawings, fitting of SF6 gas pipeline febrication of air / oil pipeline as required, electrical wiring from pole to control cubicle. fixing of terminal connectors as required, but excluding commisioning of CB, for all types of operating mechanism as required.

-

-

-

... More
(i) 220 KV Circuit Breaker

6

136049

19216

... More
(ii)132 KV Circuit Breaker

9

161668

15223

... More
Erection of 33KV or 11 KV Circuit Breakers including transport- Tation of equipment, structure members nuts & bolts clamps &Connectors etc. from site store to location, assembly of support Structure their placing on foundation, leveling and preparing for Grouting as required, but excluding grouting assembly/placing of Poles, mechanism box etc on support structure as per manufacturer’s Drawings fitting of terminal connectors, etc but excluding Commissioning of CB.

-

-

-

... More
i) 33KV or 11KV Outdoor Type (VCB/SF 6)

8

69893

7404

... More
Erection of Post Insulators on already erectedstructures including transportation of P. i. 's nuts & bolts ,clapms & connectors etc. from site store to locations, fabrication of base frame & assembly if required ,fixing of clamps etc.

-

-

-

... More
(i) 220 KV PI

42

43761

883

... More
(ii) 132 KV PI

3

2354

665

... More
(iiI) 33 KV OR 11 KV

6

531

75

... More
Erection of 132KV Class EHV Transformer (tank already placed on foundation with wheels), including transportation of accessories from site store to locations, erection of HV, IV, LV & Neutral bushings main & OLTC conservators, radiators, equalizing pipe line marshalling kiosk, etc. as per manufacturer’s drawing, prepare- tion of oil, oil filling dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment, e.g, Buchholz relay, MOLG, OSR, etc to marshalling kiosk, etc. but excluding testing & commissioning of transformer.

-

-

-

... More
a) In case electricity is made available by RVPN without charges.

-

-

-

... More
i) Transformers received oil filled

1

49665

42089

... More
Erection of 220 KV Class EHV Transformer (Gas filled tank already placed on foundation with wheels) including transportation of accessories from site atore to location, erection of HV, IV, LV & Neutral of bushings, erection of cooler bank with associated pipeline, rediators, fans, pump, main & OLTC conservator ,equilising pipe line, marshling kiosk etc. as per manufectures drawing, preparation of oil, oil filling, dehydration of transformer alongwith cooler bank & diverter switch (Filter machine,oil tank & operating staff shall be provided by RVPN), electrical wiring from indivisual equipment e.g. buchholz relay, MOLG, OSR, fans, pumps, bushing CT's etc. to marshlling kiosk etc. but excluding testing & commisioning of transformer.

-

-

-

... More
a) If electricity is available & arranged by RVPN without charges.

1

151743

128596

... More
Erection of control & Relay Panels complete in all respects including transportation from site store to control room, placing on foundation / cable trench as per layout, interconnection between control & relay panels and with existing panels, fixing of side / top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control & relay panel as required

-

-

-

... More
i) 2x2 Duplex Panel

-

-

-

... More
ii) Duplex Panel

15

22390

1265

... More
iii) Simplex Panel, DC Panel, RTCC Panel,PTCC Panel etc.

22

16406

632

... More
iv) L.T. Panel

1

2052

1739

... More
Erection of Marshalling Kiosk/ Line matching unit(LMU) / Line matching & Distribution unit (LMDU) complete in all respect including transportation from site store to locations, placing on foundation / cable trench as per layout, preparing for grouting of foundation bolts but excluding grouting etc.

-

-

-

... More
i) 220/132 KV Marshalling kiosk

18

7943

374

... More
ii)33 KV OR 11 KV Marshalling kiosk

8

1812

192

... More
Erection of Battery charger complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout. Etc.

-

-

-

... More
i) 220 Volt DC, 400 AH

2

2985

1265

... More
A. Assembly, erection and commissioning of Lead Acid Battery set including transportation of cells, battery stand, nuts & bolts and accessories from site store to battery room, assembly of wooden stand, placing the cells on stand, making their interconnection, filling of electrolyte, give two cycle of charge and discharge after initial charging as per procedure recommended by battery manufacturer.

-

-

-

... More
a) If electricity is available & arranged by RVPN without charges.

-

-

-

... More
i) 220 Volt DC, 400 AH

2

62032

26285

... More
iv) Additional cycle of discharging & charging, if required.

2

10799

4576

... More
B. Assembly, erection and commissioning of Lead Acid Battery set including transportation of cells, battery stand, nuts & bolts and accessories from site store to battery room, assembly of wooden stand, placing the cells on stand, making their interconnection, filling of electrolyte, give two cycle of charge and discharge after initial charging as per procedure recommended by battery manufacturer.

-

-

-

... More
a) If electricity is available & arranged by RVPN without charges.

-

-

-

... More
iii) 48 Volt DC, 600/400/200 AH

2

15606

6613

... More
iv) Additional cycle of discharging & charging, if required.

2

10799

4576

... More
LAYING AND TERMINATION OF CABLES

-

-

-

... More
Control Cable

-

-

-

... More
i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenchs as per specification as required, including transportation of cable drums from site store to locations, laying in cable trenches, cutting to required length, placing them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trench covers as required, making necessary connections, testing, cable marking on both the terminating ends, etc. as required for all sizes from 2c x 2.5 sq.mm. to 20c x 2.5 sq.mm. , 4c x 4 sq.mm. & 4c x 6 sq.mm.

-

-

-

... More
a) Unarmoured control cable

55000

324500

5

... More
ii) fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three matal washers & one rubber ring including preparation of cable & drilling of corresponding holes in gland plates etc. as required and including post of cable glands, for each cable gland of size.

-

-

-

... More
a)19 mm unarmoured control cable

500

25960

44

... More
b)25 mm unarmoured control cable

200

15812

67

... More
c)32 mm unarmoured control cable

100

11328

96

... More
iii) Termination of wires of cables with copper coductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - incharge) duly drimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires, etc. as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes.

-

-

-

... More
a) 2,5 sq.mm for any number of core

7000

90860

11

... More
b) 4 sq.mm for any number of core

2000

33040

14

... More
L.T.Control Cables

-

-

-

... More
i) Laying of PVC insulated sheathedarmoured / unarmoured L.T.cables of 1.1 KV grade with alluminium conductor as per IS:12355 in ground / cable trenchs / well surface including transportation of cable drums from site store to locations, execavation of 30 cm x 75 cm size trenchs providing 25 mm thick under layer of sand & 2nd clas brick covering & refilling earth in remaining postion, fixing as per approved specing by means of M.S.U. clamp etc. as per specification , including making as required of folling sizes.

-

-

-

... More
c) 3.5 core x 300 sq mm

500

31270

53

... More
ii) fixing of power cable in position with single compression heavy duty nickle plated brass cable glands as per IS: 12943 & having three metal washers & one rubber ring including preparation of cable & drilling of corresponding holes in gland plates etc. including post of cable glands,if required for each cable gland of size.

-

-

-

... More
g) 75/76 mm 3.5 core x 300 sq mm cable with material

2

1043

442

... More
iii) Termination of wires of cables with alluminium coductor using alluminium terminal ends as per IS: 8309 duly drimped with crimping tool, including making wire ends ready for crimping, ferruling & dressing of wires, etc. as required, including cost of terminal ends is required, for each cable at (4 Nos. per end) for cables of the following sizes.

-

-

-

... More
g) 3.5 core x 300 sq mm cable with material

2

1935

820



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.