Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 47,400Document Cost
₹ 1,180Tender Fee
₹ 590
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRVPN_431130_1Tender No
2610002404Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S Flat at a depth of 0.80 meters from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S Flat from site store to locations, preparation of risers bending as per requirement ( after heating if necessary), fixing on and welding / bolting to equiopment/ structure and peaks of structures, laying in the trench, welding to the earth mesh of M.S Rods as per drawing, including welding of extra length of M.S Flat of required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 meter below top level of foundations ( M.S Rod of above sizes & M.S Flat as required shall be made available by RVPN) (a) In case electricity is made available by RVPN without charges 2.1 Any soil, soft rock other than hard rock
3000
28
85200
... More
(ii) Hard rock (with blasting subject to permission or withour blasting)
1500
59
88500
... More
Placing / Driving of earth electrode of 25 / 28 mm dia. M.S. Rod of length 3.30 meter (Approx.) to a depth 3.80 meter from top level of foundation,including excavation of pit as required and back filling of the same, transportation of M.S.Rod from site store to locations,cutting of M.S.Rod to desired length, preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M.S.Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 meters below top level of foundation (M.S.Rod of above sizes & M.S. Flat as required shall be made available by RVPN) (a) In case electricity is made available by RVPN without charges. 3.1 Any soil, soft rock other than hard rock
30
273
8193
... More
(ii) Hard rock (with blasting subject to permission or withour blasting)
25
932
23300
... More
Placing / Driving of earth electrode of 25 / 28 mm dia. M.S. Rod of length7.50 meter (Approx.) to a depth 8.00 meter from top level of foundation,including drilling of 200 mm dia earth it having a throughout bore of 200 mm dia to a depth of 8.00 meter from thethe top Level of the foundations in all types of rocks by DTH system and Over burden, including back filling of pit with Bentonite slurry(with Cost of Bentonite slurry), including its preparation, transportation of M.S.Rod and Benonite from site store to locations, cutting of M.S.Rod to desired length welding of earth electrode to earth mesh of M.S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints. (M.S.Rod of above sizes & M.S.Flat as required shall be made available by RVPN) (a) In case electricity is made available by RVPN without charges. 4.1 Any soil, soft rock other than hard rock
65
11230
729950
... More
ERECTION OF SUB STATION STEEL STRUCTURES : columns, beams lighting mast and equiopemtn structures (excluding Circuit Breakers and Capacitors Banks ) of all types including transportation of structure members nuts & bolts, washers etc from site store to locations , their assembly, placing on foundation, fxinmg of template, with foundation bolts as required, levelling and preparing for grounding as required but excluding grouting erection after grouting and tightening & punching of nuts & bolts. ( Maximum height of structures upto 20 meters.
100
2321
232100
... More
Bus Bar Work: STRINGING OF 220 KV , 132 KV, 33 KV & 11KV Bus Bar of ACSR conductor, including transportation of counductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available fitting of bolted type or compression type tension hardware as made available ( compression machine shall be provided by RVPN on rent free basis ) making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor for three phases of conductors in each bus section (Per Jumper basis). 5.1 i) Any Single Conductor
27
1165
31455
... More
ii) Any Double Conductor
15
1758
26370
... More
JUMPERS OF ACSR conductor ( 3 nos Y type ) between bus to equipment or between equipment to equiopment or between bus to bus, including transportation of conductor, disc insulatros and hardware from site stiores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections,fixing of spacers & spacer T clamps as required tightening of clamps / connectors, dressing etc for three phases (Per Jumper basis) 6.1 Any Single Conductor
240
111
26640
... More
STRINGING OF Earth wire ( size 7/3.15mm or 7/4.00mm ), including transportation of eathwire, tension hardwares, etc from site store to locations lasying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available ( comppression machine shall be provided by RVPN on rent free basis), making up at one end stringing of earthware between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earthwire.
60
292
17520
... More
ERECTION OF SUB-STATION EQUIPMENTS: (i) Erection of 33/.4KV or 11/0.4 KV Station Transformer upto 500KVA on existing masonry platform including transportation of transformer and accessories from site store to location, erection of horn gap, jumpering from isolator to horn gap to transformer.
1
3967
3967
... More
Erection of C.T / P.T /CVT/ Series Reactor / RVT / NCT with clamps & connectors on already erected steel structure including transportation from site stores to locations, fabrication of base frme, fixing of terminal connectors, tightening of nuts & bolts etc complete in all respect. ii) 132KV CT/PT/CVT/
18
1415
25470
... More
iii) 33 KV or 11 KV CT/PT
27
532
14364
... More
Erection of LA on already erected steel structure including transportation of LA, clamps & connectors surge counter etc from site stores to locations, fabrication of base frame, fixing of terminal connectors surge counter, tightening of nuts & bolts complete in all respect. i) 132 KV
6
1422
8532
... More
33 KV or 11 KV
18
317
5706
... More
Erection of Isolators on already, erected steel structures including transportation of base frame, P.I's contacts mechanism box clamps & connectors etc from site store to locations minor fabrication as required and fixing of termnial connectors etc adjustment / aligment of isolator and its earth blade, if provided for their smooth operation and final adjustment if required after jumpering including erection of PI (i) 132 KV (a)(withour earthblade)
8
2596
20768
... More
132 KV: a) With single Earth Blade
3
3045
9135
... More
33 KV &11 KV : a) Without Earth Blade
20
916
18320
... More
33 KV &11 KV b) With single Earth Blade
5
1364
6820
... More
Erection of Wave trap on already erected structure beam, including transportation of wave trap, disc insulators, hardware, clamps and connectors etc from site store to locations, cleaning & assembly of disc insulators alongwith fitting of suspension arrangement and erection fixing of terminal connectors etc. 132 KV
2
599
1198
... More
Erection of 220KV or 132 KV Circuit Breakers, including transportation of equipments, structure members, nuts & bolts, clamps & connectors, accessories etc from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting assembly/ placing of support columns / poles mechanism box/control cubicle, and other accessories as per manufacturer's drawings, fitting of SF-6 gas pipeline, fabrication of air / oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required but excluding commissioning of CB for all types of operating mechanism, as required. ii) 132 KV
3
15223
45669
... More
Erection of 33 KV or 11 KV Circuit Breakers including transporation of equipemt, structure members nuts & bolts, clamps & connectors etc from site store to location assembly of support structure their placing on foundation leveling and preparing for grouting as required but excluding grouting assembly/placing of poles, mechanism box etc on support structure as per mannufacturer's drawings, fittings of terminal connectors etc but excluding commissioning of C.B. i) 33 KV or 11 KV Outdoor Type (VCB/SF-6)
7
7404
51828
... More
Erection of Post Insulators on already erected structures including transportation of PI nuts & bolts, clamps & connectors etc from site store to locations, fabrication of base frame & assembly if required, fixing of clamps etc. (I) 132 KV
6
665
3990
... More
33 KV or 11 KV
6
75
450
... More
Erection of 132KV class EHV Transformer (tank already placed on foundation with wheels), including transportation of accessories from site site store to locations, erection of HV & LVNeutral bushing, main & OLTC conservators, radiators, equilizing pipe line, marshalling KIOSK etc. as per manufacturer's drawing, preparation of oil, oil filling, dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN), electrical wiring from individual equipment e.g. Buchholz relay, MOLG, OSR etc. to marshalling KIOSK etc. but excluding testing & commissioning of transformer. (a) In case electricity is made available by RVPN without charges i) Transformer received Oil filled
1
42089
42089
... More
Erection of control & Relay Panles complete in all respect including transportation from site store to control room placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side/ top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel, as required. i) Duplex Panel
3
1265
3795
... More
iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc
9
632
5688
... More
iv) LT Panel
1
1739
1739
... More
Erection of Marshalling Kiosk/ Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout preparing for grouting of foundation bolts but excluding grouting etc. i) 220 KV or 132 KV Marshalling kiosk
3
374
1122
... More
ii) 33KV or 11 KV Marshalling Kiosk
8
192
1536
... More
Erection of battery Charger complete in all respect including transportation from site store to location, placing on foundation/cable trench as per layout (ii) 110V DC 200Ah
1
1265
1265
... More
BATTERY SET: Assembly erection and commissioning of Lead Acid Battery Set including transportation of cells, battery stand, electrolyte, nuts & bolts and accessories from site store to battery room,assembly of wooden stand, placing the cells on stand, making their interconnection, initial charging discharging and final charging as per procedure recommended by battery manufacturer. (a) In case electricity is made available by RVPN without charges (i) 110V DC 200Ah
1
24621
24621
... More
LAYING AND TERMINATION OF CABLES: Control Cables: i) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with coppetr conductor in cable trenches as per specification as required, including transportation of cable drums from site them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trench covers as required making necessary connections testing cable marking on both the terminating ends, etc as required for all size from 2c x 2.5sqmm to 20cx2.5mm, 4c x 4sqmm and 4cx6sqmm a) Unarmoured control cable
18000
5
90000
... More
ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS : 12943 & having three metal washers and one rubber ring, inluding preparation of cable and drilling of correspomding holes in gland plates, etc. as required & including cost of cable glands for each cable gland of size a) 19 mm Unarmoured Control Cable
150
44
6600
... More
c) 25 mm Unarmoured Control Cable
60
67
4020
... More
e) 32 mm Unarmoured Control Cable
60
96
5760
... More
iii) Termination of wires of cables with copper conductor using copper terminal ends ( pin or ring type as required of Dowell's or equivalent make as approved by the Engineer- In-Charge ) duly crimpede with crimping tool including making wire ends ready for crimping, ferruling & dressing of wires, etc as required , including cost of terminal ends for all wires for each cable at both ends for cables of the following sizes. a) 2.5 sqmm for any number of core
4000
11
44000
... More
b) 4.0 sqmm for any number of core
800
14
11200
... More
LT Power Cable: (i) Laying of PVC insulated armored/Unarmoured LT Power Cable of 11KV Grade with Aluminium condutor including transportation and excavation of 30cmX75Cm trench providing 25mm thick under layer of sand as per required including making necessarry connection. (i) 3.5CX300 Sq. mm.
250
53
13250
... More
ii) Fixing of Power cables in position with single compression heavy duty nickel plated brass cable glands confirming to IS : 12943 & having three metal washers and one rubber ring, inluding preparation of cable and drilling of correspomding holes in gland plates, etc. as required & including cost of cable glands for each cable gland of size g) 75/76 mm. for 3.5 coreX 300 Sq. mm. cable with material
2
442
884
... More
iii) Termination of wires of cables with aluminium conductor using ISI marked tubular aluminium terminal ends as per IS : 8309 duly crimpede with crimping tool including making cable ends ready for crimping and providing insulation tape with colour code, dressing of wires, etc , including cost of terminal ends if required for each end of cable (4 nos. per end) for the following size of cables. g) 3.5 coreX 300 Sq. mm. cable with material
2
820
1640
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%