Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 16,860Document Cost
₹ 1,180Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RRVPN_383996_1Bid Award Id
ViewTender No
SE/TnC/JPRCityTender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Augmentation work of shifting of existing 33 KV swicthyard at 220 KV GSS NPH to new location due to settlement of soil at old location
augmentation work of shifting of existing 33kV switchyard at 220kV GSS NPH Jaipur to new location
BOQ Items
Placing/Drawing of earth electrode of 28 mm dia.M.S.Rod of length 3.30 meters(approx) to a depth of 3.80 meters from the top level of foundations, including excavation of pit as required and backfilling of the same transportion of M.S. Rod from site to locations,cutting of M.S. Rod to desired length preparation of one end as spike if necessary ,welding of earth electrode to earth mesh.OF M.S. Rod as per drawing,application of btumen compound and covering with bitumen impregnated tapon all welded joints,for the type of soil prevalent at 3.80 metres below top level of foundation (M.S.Rod of above sizes&M.S.Flat as required shall be made available by RVPN. a)In cash electricity is made available by RRVPNL without charges.( i) Any soil soft rock other than hard rock
30
8193
273.1
ERECTION OF SUB-STATION STEEL :Structures colums,beams,lighting mastand equipment structures(excluding circuit breaker andcapicator bank) of all types including transportation of structure
45
104445
2321
BUS BAR WORK:-Erection of 220KV,132KV,33KV bus bar of ACSR & Tarantulla conductor,disc insulators and tension hardware from site store to locatoins,laying and cutting required length of conductor, cleaning and assemly of disc insulators as required along with fitting of bollted type or compression type tension H/W as made availlable(compression machine shall be provided by RVPNon rent free basis),making up at one end,stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers spacer T clamps for twin conductors,for three phase of conductor in each bus section.(Per Jumper Basis)
-
-
-
i)Single ACSR zebra
30
34950
1165
ii)Double ACSR zebra
48
84384
1758
JUMPERSof ACSR conductor(3nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/ connectors, dressing ect. For three phases (Per Jumper Basis)
-
-
-
1)Any conductor
270
29970
111
STRINGING of earth wire (size7/3.15mm 7/4 mm ) including transportion of earth wire,tensions hardware etc.from site store to loctions, laying and cutting required length of earth-wire ,fitting of bolted type or compression type hardware as made available(compression machine shall be provided by RVPN on rent free basis),making up at one end, stringing of earthwire between structure peaks with speci- sag and tension,jumpering and connecting earth bonds,for single earth wire
24
7008
292
ERECTION OF SUB-STATION EQUIPENTS:-Erection of Current Transformer/Potencial Transformer/Capcitive Voltage Transformer with clamps & connectors on already erected steel structure including transportion from site store to locations, fabrication of base fram,fixing of terminal connectors lightening of nuts& bolts etc.complete in all rsepects
-
-
-
ii) 33 KVCT/PT
30
15960
532
Erection of lightening Arrestor on already erected steel structure including transportion of lighting Arrestor,clamps&connectors,surge counter etc. from site store to locations fabrication of base frame, fixing of terninal connectors surge counter, tighting of nuts&bolts etc. complete in all respect.
-
-
-
i) 33 KV LA
9
2853
317
Erection of isolarors on already erected steel structure including transportion of base fame,P.I.'s contacts,mechanim box,clamps&connectors etc. from the site store to locations,minor fabrication as required and fixing of terminal connectors etc adjustment/aligment of isolator and its earth blade, if provided for their smooth opertion and final adjustment if required after jumpering. i)33KV
-
-
-
a) without Earth Blade
29
26564
916
a) with Earth Blade
6
8184
1364
Erection of 33 Circuit Breaker including transportation of equipment structure members nurts & bolts,clamp & connectors, accessories etc from sitestore to location,assembly of support structure their placing on foundation,levelling and preparing for grouting as required but excluding gouting, assembly placining of support columns/poles mechanim box/control cubicle and other accessories as per bmanufacture,s drawings filling of sf6 gas pipeline,fabrication og air/oil pipeline as required,electrical wing from pole to control cubicle. fixing of terminal connectors as required but excluding commissiong of CB .
-
-
-
i) 33 KV CB
10
74040
7404
Erection of marshaling kiosk/line matching unit (LMU)/line matching &distribution unit (LMDU)complete in all respect including transportion from site store to loction,placing on foundation/cable trench as per layout ,preparing for grounting on foundation bolts but excluding grouting etc.
-
-
-
ii) 33 KV or 11 KV marshalling box
7
1344
192
LAYING AND TERMINATION OF CABLES. :-i)Laying of PVC insulated unarmored /armored control cables of 1.1 kv grade with copper condutor in cable trenches as per sepecification as required, including transportion of cable drum from site store to locations,cutting to required length,placing them on cable racks/cable trays/ cable batten and dressing,including removing and re-fixing trench covers as required, making necessary connections testing,cable marking on both termimating ends,ets. as required for all size from 2cx2.5 sq.to 20x2.5sq mm & 4x4 sq mm
-
-
-
a)Unarmored control cable
5
30000
6000
ii) Fixing of control cable in position with single compression nickle plated brass cable glands confirming to IS 12943 & having three metal washers and one rubber ring including preparion of cables and drilling of corresponding holes in gland plated etc as reuired & including cost of cable glands,for each gland sizes.
-
-
-
a) 19 mm Unarmored control cable
44
5280
120
b) 25 mm Unarmored control cable
67
2680
40
c) 32 mm Unarmored control cable
96
-
-
iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell,s or equivalent make as approved by the Engineer-In-charge) duly clamped with crimping tool,including making wire ends ready for crimping ferruling & dressing of wire etc as required including cost of terminal ends for all wires for each cable al lboth ends for cables of the following sizes
-
-
-
a) 2.5 sq.mm for any number of core
11
5280
480
b) 4 sq.mm for any number of core
14
560
40
c) 6 sq.mm for any number of core
14
-
-
PART "B" FOR DISMENTALING WORK :-Laying of earthing risers of 50x12 mm upto 50x6 mm size M.S. Flate at a depth of .80 meter from top level of foundation including excavation of trench of required depth and backfilling of the same transportation of M.S. Rod from site store to locations,preparation of risers bendinf as per requirement (after heating if nccessary(,fixing on and welding /bolting to equipment/structure and peacks of structures layinf in the trench welding to the earth mesh of M.S Rod as per drawing, including welding of extra length of M.S.Flate required application of btumen compound and if covering with bitumen impregnated tap on all welded joints,paiting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at0 .80 metre below top level level of foundatios(M.S.Rod of above sizes&M.S. Flate as rquired shall be made available by RVPNL).a)In cash electricity is made available by RRVPNL without charges.
-
-
-
( i) Any soil soft rock other than hard rock
28.4
3408
120
ERECTION OF SUB-STATION STEEL
-
-
-
Structures colums,beams,lighting mastand equipment structures(excluding circuit breaker andcapicator bank) of all types including transportation of structure members,nut&bolts washers etc. from site store to locations their assembly, placing on foundation,fixing template,with foundation bolts as required,levelling andpreparing for grouting as required,but excluding grouting erection after grouting and toghtehing&punching of nut&bolts. (maximun height of structures up to 20 meters)
50
69630
1392.6
BUS BAR WORK :- 26-02-2024 26-02-2024-Dismantling of 220KV,132KV,33KV bus bar of ACSR & Tarantulla conductor,disc insulators and tension hardware from site store to locatoins,laying and cutting required length of conductor, cleaning and assemly of disc insulators as required along with fitting of bollted type or compression type tension H/W as made availlable(compression machine shall be provided by RVPNon rent free basis),making up at one end,stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers spacer T clamps for twin conductors,for three phase of conductor in each bus section.(Per Jumper Basis)
-
-
-
i)Single ACSR zebra
36
25164
699
ii)Double ACSR zebra
18
18986
1054.8
JUMPERSof ACSR conductor(3nos Y type)between equipment or between bus to bus,including transportion of conductor,disc insulators and hardware from site stores to locations ,cleaning and assembly of disc insulators as along with fitting of suspension hardware and erectoin as reqired, cutting reqired length of conductor, making connections,fixing of spacers & spacer T-clamps as reqired,tightiening of clamps/ connectors, dressing ect. For three phases (Per Jumper Basis)
-
-
-
1)Any conductor
250
16650
66.6
DISMENTALING OF SUB-STATION EQUIPENTS :-Erection of Current Transformer/Potencial Transformer/Capcitive Voltage Transformer with clamps & connectors on already erected steel structure including transportion from site store to locations, fabrication of base fram,fixing of terminal connectors lightening of nuts& bolts etc.complete in all rsepects
-
-
-
ii) 33 KVCT/PT
30
9576
319.2
Erection of lightening Arrestor on already erected steel structure including transportion of lighting Arrestor,clamps&connectors,surge counter etc. from site store to locations fabrication of base frame, fixing of terninal connectors surge counter, tighting of nuts&bolts etc. complete in all respect.
-
-
-
i) 33 KV LA
18
3423
190.2
Erection of isolarors on already erected steel structure including transportion of base fame,P.I.'s contacts,mechanim box,clamps&connectors etc. from the site store to locations,minor fabrication as required and fixing of terminal connectors etc adjustment/aligment of isolator and its earth blade, if provided for their smooth opertion and final adjustment if required after jumpering. i)33KV
-
-
-
a) without Earth Blade
29
15938
549.6
b) with Earth Blade
6
4910
818.4
Erection of 33 Circuit Breaker including transportation of equipment structure members nurts & bolts,clamp & connectors, accessories etc from sitestore to location,assembly of support structure their placing on foundation,levelling and preparing for grouting as required but excluding gouting, assembly placining of support columns/poles mechanim box/control cubicle and other accessories as per bmanufacture,s drawings filling of sf6 gas pipeline,fabrication og air/oil pipeline as required,electrical wing from pole to control cubicle. fixing of terminal connectors as required but excluding commissiong of CB .
-
-
-
i) 33 KV CB
10
44424
4442.4
Dismantling of Post insulator on already erected structures including transporation of P.I's, nuts & bolts, clamp and coonectors etc from location to site store.
-
-
-
iii) 33KV or 11KV
45
2025
45
Erection of marshaling kiosk/line matching unit (LMU)/line matching &distribution unit (LMDU)complete in all respect including transportion from site store to loction,placing on foundation/cable trench as per layout ,preparing for grounting on foundation bolts but excluding grouting etc.
-
-
-
ii) 33 KV or 11 KV marshalling box
4
460
115.2
LAYING AND TERMINATION OF CABLES Control Cables.i)Laying of PVC insulated unarmored /armored control cables of 1.1 kv grade with copper condutor in cable trenches as per sepecification as required, including transportion of cable drum from site store to locations,cutting to required length,placing them on cable racks/cable trays/ cable batten and dressing,including removing and re-fixing trench covers as required, making necessary connections testing,cable marking on both termimating ends,ets. as required for all size from 2cx2.5 sq.to 20x2.5sq mm & 4x4 sq mm
-
-
-
a)Unarmored control cable
3000
9000