Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 75,773Document Cost
₹ 2,950Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_RRVPN_207565_1Bid Award Id
ViewTender No
1310002002Tender Authority
Rajasthan Rajya Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://energy.rajasthan.gov.in/content/raj/energy-department/rajasthan-rajya-vidyut-prasaran-limited/en/home.html
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of 132 KVSingle circuit Line on towers fit for double circuit for Railway Traction Substation at Maonda and Modification of Existing 220 KVlines crossing this line.
BOQ Items
SETTING OF TEMPLATE & STUB/ANCHOR BOLT (A) Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming and watering as per specification.
1
-
-
(i) Towers including extension upto 9 Meters ( 132 KV D/C TTA-7,TTB-8,TTC-5,TTD-15)
14
-
17327
(ii) Special towers for any span including extension (220 KV D/C SPL.STR.)
0.4
-
20829
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size, water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
1
-
-
(ii) 1:3:6 Mix
46
-
8525
(iii) 1:2:4 Mix
50
-
8784
(iv)1:1.5:3 Mix
162
-
10715
Cutting, bending, welding ofjoints if required, fixing and placing of steel reinforcement as per specification and drawings including material.
18.5
-
61496
EARTHING:(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation, augering and backfilling in all types of soil.
36
-
1568
ERECTION OF TOWERS:-Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
1
-
-
i) Erection of towers(with extensions upto 9 Meters)
172
-
4876
(ii) Erection of special towers(with extensions)
8
-
7212
CONDUCTOR STRINGING:-(A) Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line. i) Single conductor
27
-
9624
EARTHWIRE STRINGING:-(A) Stringing of galvanised steel stranded wire including laying, jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc. (i) One No. 7/3.15mm galvanised wire
9
-
6713
Modification of Existing 220 KV S/C KHETRI-BEHROR LINE , 220 KV S/C KHETRI-BABAI Ist Line, 220 KV S/C KHETRI-BABAI IInd Line220 KV D/C BABAI-MAONDA DFCC LINE.
1
-
-
Detail Survey as per tentative route which includes the following major activities- Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
4
-
8756
Check survey as per approved route of line which includes - Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
4
-
3255
Excavation Excavation, excluding back filling, including shoring, shuttering, dewatering,etc. upto the required depth as per foundation specification/drawings.(i)Any soil,soft rock other than hard rock
170
-
392
SETTING OF TEMPLATE & STUB/ANCHOR BOLT Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming and watering as per specification.( 220 KV D/C SPL str.) (i) Towers including extension upto 9 Meters
1.3
-
17327
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size, water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
1
-
-
(ii) 1:3:6 Mix
0.6
-
8525
(iii) 1:2:4 Mix
15.7
-
8784
Cutting, bending, welding ofjoints if required, fixing and placing of steel reinforcement as per specification and drawings including material.
0.4
-
61496
EARTHING:(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
4
-
1568
ERECTION OF TOWERS: -Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint. i) Erection of towers(with extensions upto 9 Meters)
25
-
4876
CONDUCTOR STRINGING(B) :- Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.(a) Sinele conductor
1.5
-
12332
EARTHWIRE STRINGING (i) One No. 7/3.15mm galvanised wire
0.4
-
6713
DISMANTLING OF TOWERS:-Dismantling of super structures alongwith extensions, having tack welded Bolts & Nuts, including removing of D shackles, hangers, U-Bolts, step bolts, ACD, Danger plate, number plate, Phase plate of tower including transportation from site to our store and stacking of all material(A) 132 KV and 220KV S/C & D/C Towers (all types)
16.5
-
5846
DESTRINGING OF CONDUCTOR (A) Destringing upto ACSR panther conductor : Dismantling of vibration damper and armour rods, removal of conductor from clamps and fitting in rollers,tensioning,dehoisting of insulator string as required and collecting the material & depositing the same in our store and stacking.(i) Single conductor
1.5
-
13565
(C) Destringing of Earth wire :-Dismantling of earth bonds, vibration dampers, declipping & fitting in rollers, detensioning and collecting the material & depositing the same in our store and stacking.(i) One No. 7/3.l5mm galvanised wire
0.4
-
7374
RESTRINGING OF CONDUCTORL:- Restringing of ACSR Zebra conductor: Dismantling of vibration dampers and armour rods, fitting in rollers, de-tensioning, holding & lowering of conductor, de-hoisting of insulator string as required, adding/ removing and jointing of conductor, hoisting of insulator string, lifting of conductinto rollers and re-tensioning, jointing, fitting of armouT rods and and vibration dampers and clamping per route KM of the line section to be restrung dismantled material not re-used to be deposited in our stores & stacked(i) Single conductor
45
-
12332
(C) Restringing of Earthwire:-Dismantling of earth bond, vibration dampers, declipping & fitting in rollers, de-tensioning, holding & lowering of Earthwire, adding/ removing and jointing of Earthwire, lifting into rollers and re-tensioning, jointing, clipping & fitting of vibration dampers & earthbond per route KM of the line section to be restrung. Dismantled material not re-used to be deposited in our stores & stacked.(i) One No. 7/3.15mm galvanised wire
12
-
6713
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements