Rajasthan Rajya Vidyut Prasaran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan Rajya Vidyut Prasaran Nigam Limited - RVPN Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2023
Closing Date23 Jul 2024
Tender Amount₹ 93,32,00,000 
Notes
Download

Costs

  • EMD

    ₹ 1,86,64,000
  • Document Cost

    ₹ 23,600
  • Tender Fee

    ₹ 2,950

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Insulating Oil for 160 MVA 220/132 kV Auto Transformer as per S-I , (1) above

1

-

-

... More
Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers at S-I (1) above

1

-

-

... More
Bus Reactor:

-

-

-

... More
220 kV, 25 MVAR Bus Reactor with all accessories (excluding transformer Oil) as per technical specification

1

-

-

... More
Insulating Oil for 220 kV, 25 MVAR Bus Reactor above

1

-

-

... More
Power Transformer:

-

-

-

... More
132/33 kV, 20/25 MVA Power Transformer with all accessories (excluding transformer Oil) as per technical specification

1

-

-

... More
Insulating Oil for 20/25 MVA 132/33 kV Power Transformer S-II (4) above

1

-

-

... More
Digital RTCC Panel consisting of Digital RTCC relay as per technical Specification for transformers S-II, (4) above

1

-

-

... More
Circuit Breakers

-

-

-

... More
220 kV Circuit Breakers

-

-

-

... More
220kV circuit breakers (3 Ph.) Along with support Structure

-

-

-

... More
2500 A, 50 kA

5

-

-

... More
132 kV Circuit Breakers

-

-

-

... More
132 kV circuit breakers (3 Ph.) Along with support Structure

-

-

-

... More
1250 A, 40 kA

7

-

-

... More
33 kV Circuit Breakers

-

-

-

... More
33 kV circuit breakers (3 Ph.) Along with support Structure

-

-

-

... More
1250 A, 25 kA

8

-

-

... More
Instrument Transformers

-

-

-

... More
Capacitor Voltage Transformer

-

-

-

... More
Single-Phase, 220 kV, 4400 pf CVT

12

-

-

... More
Single Phase 132 kV , 4400 pf CVT

15

-

-

... More
33 kV Potential Transformer

-

-

-

... More
33/√3 kV /110-110√3

6

-

-

... More
Current Transformer (1-Phase)

-

-

-

... More
220 kV CT

-

-

-

... More
1000/1 A, 5C

18

-

-

... More
132 kV CT

-

-

-

... More
1000/1 A, 3C

6

-

-

... More
500/1 A, 3C

15

-

-

... More
33 kV CT

-

-

-

... More
1000/1 A, 4C

6

-

-

... More
500/1A, 2C

18

-

-

... More
C&R Panels & SAS system (Complete in all respect, refer Section-V A, B, Part-III, Volume-II)

-

-

-

... More
New Substation

-

-

-

... More
Control Panel for 220 kV Transformer (220 kV Side) Type: SAS-THCB

1

-

-

... More
Relay Panel for 220 kV Transformer (for both HV & MV) Type: SAS-THRB

1

-

-

... More
Control Panel for 220 kV Bus Reactor (220 kV Side) Type: SAS-RCB

1

-

-

... More
Relay Panel for 220 kV Bus Reactor (for both HV & MV) Type: SAS-RRB

1

-

-

... More
Control Panel for 220 kV Feeder Type: SAS-FCB

2

-

-

... More
Relay Panel for 220 kV Feeder Type: SAS-FRB

2

-

-

... More
Control Panel for 220 kV Bus Coupler Type: SAS-BCCB

1

-

-

... More
Relay Panel for 220 kV Bus Coupler Type: SAS-BCRB

1

-

-

... More
220 kV Busbar Protection Relay Panel Type: SAS-BBRB

1

-

-

... More
Control Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLCB

1

-

-

... More
Relay Panel for 220 kV Transformer (132 kV Side) Type: SAS-TLRB

1

-

-

... More
Control and Relay Panel for 1x 50/31.5/25 MVA, 132/33 kV Power Transformer Type SAS-TCRA

1

-

-

... More
Control Panel for 132 kV Feeder Type SAS-FCA

4

-

-

... More
Relay Panel for 132 kV Feeder Type SAS-FRA

4

-

-

... More
Control and Relay Panel for 132 kV Bus-Coupler Type SAS-BCRA

1

-

-

... More
Control and Protection Panel for 33 kV Feeder (I/C, O/G)/Bus-coupler/ Capacitor Bank [For TWIN FEEDER/BAY] Type-FCRD

4

-

-

... More
Station HMI [Industrial grade Computer with 21"TFT monitor as per specification requirements]

1

-

-

... More
Station HMI (Hot Standby)[Industrial grade Computer with 21"TFT monitor as per specification requirements]

1

-

-

... More
HMI View Node[Industrial grad Computer with 21"TFT monitor as per specification requirements]

1

-

-

... More
A3 Size B&W Laser Printer

1

-

-

... More
Substation Automation System Network Panel Type SAS-NW

1

-

-

... More
Modems (both sending and Receiving End) for communication to RCC & Sub SLDC for PLCC]

1

-

-

... More
Data Concentrator Unit (DCU) at Substation for RAS mounted in suitable enclosure & fully wired

1

-

-

... More
Software: Application as well as System Software as per specification requirements for various hardware elements for meeting of functional requirement of the specification.

1

-

-

... More
Substation Auxiliary Monitoring Panel Type SAS-SAMP

1

-

-

... More
Other Items:

-

-

-

... More
Fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the Substation LAN as per specification requirements.

1

-

-

... More
Transducers, Sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards.

1

-

-

... More
Surge Arresters

-

-

-

... More
220 kV LA

12

-

-

... More
132 kV LA

18

-

-

... More
33 kV LA

21

-

-

... More
Substation LT Transformer

-

-

-

... More
33/ 0.433 kV, 250 kVA LT transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil

1

-

-

... More
Batteries & Battery Charger

-

-

-

... More
Batteries (Sizing shall be as per requirement of technical specification)

-

-

-

... More
220 V [Min. 600 AH]

2

-

-

... More
48 V [Min. 600 AH]

2

-

-

... More
Battery Charger System

-

-

-

... More
220 V Float and Boost

2

-

-

... More
50 V Float and Boost

2

-

-

... More
Lighting System

-

-

-

... More
Outdoor Lighting & other Works

-

-

-

... More
Lighting Fixture Type FL-1

24

-

-

... More
Lighting Fixture Type FL-2

30

-

-

... More
Outdoor Receptacle

-

-

-

... More
Type-RP

2

-

-

... More
Type-RO

2

-

-

... More
Substation Premises Lighting

-

-

-

... More
Lighting poles

-

-

-

... More
Type-L1

3

-

-

... More
Type-D1

2

-

-

... More
Street Lighting Type-SL-L1 for mounting on poles

3

-

-

... More
Street Lighting Type-SL-D1 for mounting on Poles

2

-

-

... More
Sub-Lighting Boxes/Panels Type -SLP at Lighting Mast and Other Loaction as designated complete with all controgears and accessories, items etc.

7

-

-

... More
Lighting Panel Type ACP-2 as per technical specification

1

-

-

... More
Lighting Panel Type ACP-3 as per technical specification

1

-

-

... More
Indoor Lighting & Other Works

-

-

-

... More
Electrification

-

-

-

... More
Electric Fitting (if not covered under Civil Works) with G.I. Conduit, Junction Boxes, pull out boxes, copper wiring, Modular Switchboards, Modular Switches, GI Wire (16SWG) etc. for control room, Hall and administrative office building as per the requirements of the specifications

1

-

-

... More
Illumiation

-

-

-

... More
Lighting fixtures and Receptacles (including accessories/ materials etc. as per requirement alongwith complete accessories and mounting arrangements)

1

-

-

... More
Indoor Lignting Panels

-

-

-

... More
Lighting Panel (Indoor) Type ACP-1 as per technical specification

3

-

-

... More
Lighting Panel (Indoor) Type DCP as per technical specification

3

-

-

... More
Wall mounted fans Approx. 400 mm sweep

10

-

-

... More
Ceiling Fan - Approx. 1400mm sweep with electronic Step regulator

10

-

-

... More
Exhaust Fans

8

-

-

... More
Fire Fighting System

-

-

-

... More
Nitrogen Injection Fire Protection System for Auto Transformer (160 MVA ) complete in all respects.

1

-

-

... More
Nitrogen Injection Fire Protection System for 25 MVAR reactor complete in all respects.

1

-

-

... More
DCP Type

-

-

-

... More
i) 5 Kg.

10

-

-

... More
ii) 10 Kg.

10

-

-

... More
Carbon di oxide type – 6 Liters.

1

-

-

... More
Foam Type- 9 Liters

8

-

-

... More
Sand type

-

-

-

... More
i) GI Buckets 9 liters capacity

28

-

-

... More
ii) Steel Stands for four buckets

7

-

-

... More
Air Conditioning System

-

-

-

... More
Air Conditioning for the Rooms specified in the specifications

1

-

-

... More
1.1kV Grade PVC insulated Al. conductor FRLS power cables and copper conductor armoured FRLS control cables [Excluding the wiring required for electrical & Lighting fittings/fixtures installation in control room and other building]

-

-

-

... More
Power Cables(XLPE)

-

-

-

... More
1Cx630 sq.mm

1

-

-

... More
3.5Cx300 sq.mm

0.5

-

-

... More
Power Cable(PVC)

-

-

-

... More
1Cx150 sq.mm

1

-

-

... More
3.5Cx70 sq.mm

4.5

-

-

... More
3.5Cx35 sq.mm

2

-

-

... More
4Cx16 sq.mm

15

-

-

... More
4C x 6 Sq. mm

7

-

-

... More
2C x 6 Sq. mm

5

-

-

... More
Control Cable (PVC)

-

-

-

... More
4 CX4 Sq. mm

9

-

-

... More
3Cx2.5 sq.mm

4

-

-

... More
5Cx2.5 sq.mm

3

-

-

... More
7Cx2.5 sq.mm

4

-

-

... More
10Cx2.5 sq.mm

18

-

-

... More
14Cx2.5 sq.mm

8

-

-

... More
19Cx2.5 sq.mm

7

-

-

... More
Substation Structures

-

-

-

... More
Standard Lattice Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for lattice steel structure as per specification requirements]:

294.06

-

-

... More
Non-Standard type Pipe Support Structure [Design, engineering, procurement of materials, fabrication galvaising, proto-assembly, FOR destination delivery & erection including nuts, bolts, gusset plates, base plates, foundation bolts, fixing arrangement for control cabinets/MB of equipments and other accessories for Pipe Support structure as per specification requirements]

102.88

-

-

... More
Isolators

-

-

-

... More
220 kV (3-Phase) (Horizontal DOUBLE BREAK)

-

-

-

... More
1600A, 50KA, isolator with one E/S

5

-

-

... More
Post insulators for above Isolator

5

-

-

... More
1600A, 50KA, isolator with two E/S

4

-

-

... More
Post insulators for above Isolator

4

-

-

... More
1600A, 50KA, isolator without E/S

8

-

-

... More
Post insulators for above Isolator

8

-

-

... More
1600A, 50KA, isolator without E/S (TANDEM Type)

5

-

-

... More
Post insulators for above Isolator

5

-

-

... More
132 kV (3-Phase) (Horizontal DOUBLE BREAK)

-

-

-

... More
1250A, isolator with one E/S

4

-

-

... More
Post insulators for above Isolator

4

-

-

... More
1250A isolator without E/S

17

-

-

... More
Post insulators for above Isolator

17

-

-

... More
33 kV (3-Phase) (Horizontal DOUBLE BREAK)

-

-

-

... More
1250A, isolator without E/S

5

-

-

... More
Post insulators for above Isolator

5

-

-

... More
800 A isolator without E/S

15

-

-

... More
Post insulators for above Isolator

15

-

-

... More
800A isolator withE/S

6

-

-

... More
Post insulators for above Isolator

6

-

-

... More
Switchyard Erection

-

-

-

... More
Busbar & Interconnections

-

-

-

... More
New Substation/ Switchyard

-

-

-

... More
220 kV Switchyard Works:

-

-

-

... More
Main-I Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/Porcelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]

3

-

-

... More
Main-II Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Pocelain Long Rod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]

3

-

-

... More
Aux Bus: 220 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string(DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers, corona shields etc. as per Layout arrangment of the subsation and specification requirements [for 3 bays]

3

-

-

... More
220 kV Overhead Jack Bus (for DMT Layout) on Twin ACSR Zebra(Bus-Coupler Bay)/ Single ACSR Zebra (Transformer/ Line on ACSR Zebra) with conductor, busbar material, insulator string (DT/SS), AF Type Disc Insulators/ Porcelain Longrod Insulators, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]

-

-

-

... More
Twin ACSR Zebra

1

-

-

... More
Single ACSR Zebra

4

-

-

... More
Equipment Interconnections to Main Bus, Overhead Bus including Single ACSR Zebra (for Line), Twin ACSR Zebra (forTransformer bay & B/C Bay), bus-bar materials, clamps, connectors, spacers, corona shields, including equipment connectors, Junction box including of all accessories etc. for the following:

-

-

-

... More
220 kV DMT-type layout

-

-

-

... More
Line bay

2

-

-

... More
Transformer bay

1

-

-

... More
Reactor bay

1

-

-

... More
Bus-Coupler

1

-

-

... More
Bus CVT Interconnections to Main Buses including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.

2

-

-

... More
132 kV Switchyard Works:

-

-

-

... More
Main Bus: 132 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulator, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]

3

-

-

... More
Aux Bus: 132 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string (DT/DS), AF Disc Insulators/ Porcelain Longrod Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 4 bays]

3

-

-

... More
132 kV Overhead Jack Bus (for Main & Aux Layout) on Twin ACSR Zebra(220 kV Transformer/Bus-Coupler Bay), Single ACSR Zebra(132 kV Transformer/Bus-Coupler Bay) Single ACSR Panther (Line on ACSR Panther) on Single Panther ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]

-

-

-

... More
Twin ACSR Zebra

1

-

-

... More
Single ACSR Zebra

2

-

-

... More
Single Panther

4

-

-

... More
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Zebra (Bus Sectionalizer/ 220 kV Transformer /Bus-Coupler Bay)/ Single ACSR Zebra (132 kV Transformer Bay) Single ACSR Panther ( Line on ACSR Panther), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:

-

-

-

... More
132 kV Main & Aux-type layout

-

-

-

... More
Line bay

4

-

-

... More
Transformer bay

2

-

-

... More
Bus-Coupler

1

-

-

... More
Bus CVT Interconnections to Main Bus including Single ACSR Zebra, clamps, connectors, junction box including of all accessories etc.

1

-

-

... More
33 kV Switchyard Works:

-

-

-

... More
Main Bus: 33 kV Twin ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]

2.6

-

-

... More
Aux Bus: 33 kV Single ACSR Zebra Bus with conductor, busbar material, insulator string, Disc Insulators, hardware, Clamps, Connectors, spacers etc. as per Layout arrangment of the subsation and specification requirements [for 5 bays+ Bus Coupler]]

2.6

-

-

... More
33 kV Overhead Jack Bus for Transformer Incomer (for Main & Aux Layout) on Twin Zebra ( with conductor, busbar material, insulator string, Disc Insulators, hardware, clamps, connectors, spacers etc. as per Substation Layout arrangement and specification requirements [ for 1 Bay]

1

-

-

... More
Equipment Interconnections to Main Bus, Overhead Bus including Twin ACSR Panther ( Transformer /Bus-Coupler Bay)/ Single ACSR Panther ( Line bays), bus-bar materials, clamps, connectors, spacers including equipment connectors, Junction box including of all accessories etc. for the following:

-

-

-

... More
33 kV Main & Aux-type layout

-

-

-

... More
Line bay

6

-

-

... More
Transformer bay

1

-

-

... More
Bus-Coupler

1

-

-

... More
LT Transformer connection with ACSR Panther conductor, 33 kV DO Fuse Set alongwith required Clamp/connectors

1

-

-

... More
Bus PT Interconnections to Main Bus including Single ACSR Panther , clamps, connectors, junction box including of all accessories etc.

2

-

-

... More
Bus Post Insulators (BPI)

-

-

-

... More
220 kV

30

-

-

... More
132 kV

21

-

-

... More
33 kV

6

-

-

... More
Earthing & Lightning Protection System

-

-

-

... More
Main, Auxilary Earthmats, Risers etc. for complete earthing in the Switchyard Area

-

-

-

... More
40 mm Dia MS Rod

20

-

-

... More
40mm Dia, 3.2 M Long MS Rod Earth Electrodes Directly Driven.

100

-

-

... More
40mm Dia, 8 M Long MS Rod Earth Electrodes Directly Driven.

20

-

-

... More
40mm Dia, 3.2M Long MS Rod Earth Electrode in untreated pit with test link

75

-

-

... More
40 mm dia, 3000 mm long GS pipe electrodes with test links and treated earth pits with C.I. cover hinged to C.I. frame alongwith all associated civil works

8

-

-

... More
75X12 mm GS Flat

20

-

-

... More
50X6 mm GS Flat

20

-

-

... More
Earth Enhancing Compound for treated pits as above and other requirement as per specification

1

-

-

... More
Cleat type clamps(8mm thick) for earthing down conductor (10.98 mm dia), 50x12 mm GS Flat and 50x6 mm GS flat

1

-

-

... More
Cu/Al Flexible braids Grounding Conductor connection to MS/GS Flats

1

-

-

... More
Earth Wire for Shielding Protection of Switchyard

-

-

-

... More
7/3.15 Galvenized Steel Wire

2

-

-

... More
Earthwire tension clamps with D Shackle assembly

180

-

-

... More
PG calmp to suit 7/3.15 mm GS earth wire

120

-

-

... More
Cleat clamp on structure to suit 7/3.15 mm GS earth wire/ 50 X 12 mm GS Flat

1

-

-

... More
Pad clamp on structure to suit 7/3.15 mm earth wire and 75 x 12 GS flat

1

-

-

... More
Lug to suit 7/3.15 mm earth wire

1

-

-

... More
Other Clamps, Copper Earth Bond etc. as per layout diagram for erection of Earth Wire

1

-

-

... More
Bay Marshalling KIOSK

-

-

-

... More
200 way (Stud Type Connectors)

20

-

-

... More
AC Distribution Boxes (Outdoor Type)

-

-

-

... More
Outdoor AC Distbibution Box (Double Front type)

1

-

-

... More
Outdoor AC Distbibution Box (Single Front type)

2

-

-

... More
Conduits, Cable Trays [Perforated and Ladder Type], Cable Tags, Cable Clamps, Cable Lugs,Cable sealing system, Gland Plates, Junction Boxes, PVC pipes, hume Pipes, Nylon type Trefoil Clamps etc.[Excluding the conduits, junction boxes etc. required for electrical & Lighting fittings/fixtures installation in control room and other building]

1

-

-

... More
Other Steel Structures/ members [items such as Galvenized/ Mild Steel Channels, Angles, Plates, round, joist, Hot dip galvenized Nut-Bolts, Electro Galvenized Spring Washers etc. considered for this component of price schedule] to be designed/ provided by the bidder for the completion of project [This shall not include the steel to be used in the civil works]

5

-

-

... More
LT Switchgear

-

-

-

... More
LT AC Main Panel

1

-

-

... More
LT AC Distribution Board

1

-

-

... More
Main Lighting Distribution Board

1

-

-

... More
Emergency Lighting Distribution Board

1

-

-

... More
220V DCDB

2

-

-

... More
48V DCDB

2

-

-

... More
PLCC EQUIPMENTS

-

-

-

... More
220 kV Wave trap (2000A, 0.5 mH, 40 kA)

4

-

-

... More
132 kV wave trap (1250A, 0.5 mH, 40 kA)

4

-

-

... More
SSB single Channel Carrier Set (40 W) suitable for transmitting Data and super imposed channels along with Remote subscriber facility and emergency calling set.

8

-

-

... More
A.F. Protection coupler microprocessor based suitable for Four commands.

7

-

-

... More
Coupling Devices for Phase to Phase coupling having Band width programmable at site with protective Device & balancing transformer matching with line impedance of respective voltage level.

6

-

-

... More
HF Armoured Coaxial cable having 75 Ohms unbalanced impendance.

4

-

-

... More
Microprocessor based 32/16 line Electronic Private Automatic Exchange (EPAX) with PLCC interphasing facility

2

-

-

... More
Telephone Sets (Push Button Type)

5

-

-

... More
20 pair Jelly Filled and armoured telephone cable with copper conductor of 0.63 mm

1

-

-

... More
5 Pair jelly filled armoured telephone cable having copper conductor of Dia. 0.5 mm

1

-

-

... More
5 Pair jelly filled un armoured telephone cable having copper conductor of Dia. 0.5 mm

1

-

-

... More
TESTING & MEASURING INSTRUMENTS, TOOLS & TACKLES AND MISCELLANEOUS ITEMS

-

-

-

... More
(A) TESTING EQUIPMENT/ INSTRUMENTS [This shall consist of all the standard accessories, cables, software etc. required for satisfactory operation of equipment meeting functional requirements]

-

-

-

... More
Insulation Tester (5000 Volts, Digital)

1

-

-

... More
SF6 Leakage Detector

1

-

-

... More
Digital Multimeter

1

-

-

... More
Digital Clamp Meter

1

-

-

... More
PLCC Maintenance/Testing Equipments:

-

-

-

... More
200Hz to 620KHz selective level meter including impedance return loss measuring attachments compatible with level generator (at sl.ii below)

1

-

-

... More
Level generator with a range at 50Hz to 620kHz including facility for synchronization with SLM

1

-

-

... More
8 digit time interval & frequency counter with the frequency range of 10 Hz to 10MHz & timer range of 1 microsec to 1 sec in decade steps.

1

-

-

... More
Dual range 15 MHz oscilloscope with a display screen 8x10 sq.cm and the input impedance of 1 M ohm/25 pF with a deflection coefficient of 5Mv/div to 20 V/div.

1

-

-

... More
4-1/2 digit LCD Multimeter with input impedance of 10Mohm & with a range of 0.1 mV to 1000 V DC, 0.1mV to 600v AC, 0-10 AMP AC,(40hz to 10KHz) & 0-20 Mohm With builtin power –supply.

1

-

-

... More
Print testing Kit for PLCC terminal, protection coupler, EPAX , As per specifications appended at Annexure- V2-P3-S19-2, Volume-II, Part 3, Section-XIX

1

-

-

... More
(B) Maintenance Tools& Tackles

-

-

-

... More
Oil Sampling Bottle (1 Liter Capacity)

2

-

-

... More
Vaccum Cleaner

1

-

-

... More
Telescopic ladder aluminium 6 meter height

1

-

-

... More
Ring spanner set

1

-

-

... More
Tube spanner set

1

-

-

... More
Pipe wrench 24 inch

1

-

-

... More
Pipe wrench 18 inch

1

-

-

... More
Hydraulic crimping tools up to 630 sq.mm

1

-

-

... More
Threading die set for pipe threading

1

-

-

... More
Welding machine (arc welding) 10kVA

1

-

-

... More
Heavy duty drilling machine

1

-

-

... More
Bench Vice

1

-

-

... More
Insulated cuttingplier 12 inch

2

-

-

... More
Insulated cuttingplier 8 inch

2

-

-

... More
Screw driver 18 inch

2

-

-

... More
Screw driver 12 inch

2

-

-

... More
Hammer 8 lbs

1

-

-

... More
Hammer 2 lbs

1

-

-

... More
Chain pulley block 5 ton

1

-

-

... More
Pipe derrick

1

-

-

... More
Allen Keys

2

-

-

... More
Box Spanners

1

-

-

... More
(C )Office and Miscellaneous Equipments/ Items

-

-

-

... More
Insulation Rubber mat (1mX2mX 12 mm)

20

-

-

... More
Isulation Rubber Gloves (15 kV Tested)

6

-

-

... More
Furniture for Control Room Building:

-

-

-

... More
SCADA Room Furniture (Control Desk for specified consoles and Revolving Chair) matching with the overall interiors as per specification

1

-

-

... More
Executive Desk bulit in wood and steel with lockable drawings on both side (6 feetX2 ½ feetx 2 ½ feet)

1

-

-

... More
Junior executive table with three drawings on right side One Cup board left side with prelaminated decolam top 20mm thick over painted M.S. Frame ( 4 ½ feet x 2 ½ feetx 2 ½ feet).

2

-

-

... More
Library Shelf with Glass Door (min 4 Shelf)

1

-

-

... More
Steel tubular “S” type with continuous and one feet dia 14guage pipe, cane seat backing, teak wood with quality cane.

10

-

-

... More
Archival Storage 4 Drive Type

1

-

-

... More
Lateral Filing Cabinets

-

-

-

... More
3 Drawer Unit

1

-

-

... More
4 Drawer Unit

1

-

-

... More
Steel Almirah of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.

1

-

-

... More
Steel Almirah (with Glass doors) of size 6 ½ feetx 3 feet x 19 inch with four shelves making five compartments in 22 guage or better with two way locking system.

1

-

-

... More
Minor Almirah of size 4 ½ feet x30 inch x 17 inch with three shelves making four compartments in 22 guage or better with two waylocking system.

1

-

-

... More
Steel rack of size 5 feet x 3 feet x 16 inches with six shelves making five compartments (22 guage).

2

-

-

... More
Steel file trays of size 16 inches x11 inches x 3 inches of guage 14 SWG.

1

-

-

... More
Steel stools of size 15 inch x15 inch x 18 inch square pipe 16 guage

2

-

-

... More
Steel waste paper baskets of size 12 inch (H) and Approx. 10 inch Dia Round.

2

-

-

... More
Key board (wooden) with Glass door

1

-

-

... More
First Aid Box

2

-

-

... More
Shock Treatment Chart [Laminated with Frame]

2

-

-

... More
Safety Instruction Boards [ Laminated with Frame]

2

-

-

... More
(D) Drinking Water Arrangement

-

-

-

... More
Water Cooler (Storage type, Storage Capacity 40 Ltr, Cooling Capcity 20 Ltr./hr)

1

-

-

... More
RO/ Water Purifier

1

-

-

... More
Refrigirator (380 Lt.)

1

-

-

... More
Substation Name Board [1 No. Glow Type & 1 No. Painted Type] [Size and Color etc. be got approved from owner]

1

-

-

... More
Danger Plate [Size and Color etc. be got approved from owner]

10

-

-

... More
MANDATORY SPARES

-

-

-

... More
(A) 220/132 kV TRANSFORMER

-

-

-

... More
Bushing with metal parts & gaskets of each rating including Neutral bushing

1

-

-

... More
Local and remote winding temperature indicator complete with sensing device & contacts

1

-

-

... More
Oil temperature indicator with contacts & sensing device

1

-

-

... More
Oil cooler pump with motor

1

-

-

... More
Cooler fan with motor

1

-

-

... More
Set of starter, contactor, relays and switch for electrical control panels (1 set of each type and range)

1

-

-

... More
Buchholz relay complete with floats & contacts

1

-

-

... More
(B) 25MVAR 245 kV BUS REACTOR

-

-

-

... More
Local and remote WTI for reactor

1

-

-

... More
Local and remote OTI for reactor

1

-

-

... More
Pressure release device for reactor

1

-

-

... More
Buchholz relay with asse. for reactor

2

-

-

... More
Magnetic oil level gauge for reactor

1

-

-

... More
Set of valve (comp set for one reactor)

1

-

-

... More
Breather assembly for reactor

1

-

-

... More
(C) 132/33 kV Power Transformer

-

-

-

... More
HV bushing with metal parts and gaskets

1

-

-

... More
LV bushing with metal parts and gaskets

1

-

-

... More
Neutral bushing with metal parts and gaskets

1

-

-

... More
Magnetic oil level gauge with low oil level alarm contacts

1

-

-

... More
Winding temperature Hot indicator

1

-

-

... More
Cooler fans

2

-

-

... More
Buchlotz Relay

1

-

-

... More
(D)Circuit Breakers

-

-

-

... More
220 KV

-

-

-

... More
(One pole of circuit breaker with grading capacitor complete with pole column and interrupter with M.B. but without support structure and operating mechanism.

1

-

-

... More
Rubber gaskets, ‘O’ rings and seals

1

-

-

... More
Fixed Contacts

3

-

-

... More
Moving Contacts

3

-

-

... More
Terminal pads and connectors

2

-

-

... More
Closing Assembly Valve

1

-

-

... More
Trip Assembly Valve

1

-

-

... More
Auxiliary Switch Assembly

1

-

-

... More
Operation Counter

1

-

-

... More
Closing Coils

2

-

-

... More
Tripping coils

4

-

-

... More
Support insulator complete for one pole of breaker

1

-

-

... More
145 kV

-

-

-

... More
One pole of circuit breaker without support structure and operating mechanism.

1

-

-

... More
Rubber gaskets, ‘O’ rings and seals

1

-

-

... More
Fixed Contacts

6

-

-

... More
Moving Contacts

6

-

-

... More
Terminal pads and connectors

3

-

-

... More
Closing assembly valve

1

-

-

... More
Trip assembly valve

1

-

-

... More
Auxiliary switch assembly

1

-

-

... More
Operation counter

1

-

-

... More
Closing Coils

2

-

-

... More
Tripping coils

4

-

-

... More
Support insulator (set complete for one pole of breaker)

1

-

-

... More
(E) Instrument Transformer

-

-

-

... More
Spare of 245kV Capacitive Voltage Transformer

-

-

-

... More
(i) Complete CVT

1

-

-

... More
Spare of 145kV Capacitive Voltage Transformer

-

-

-

... More
(i) Complete CVT

1

-

-

... More
Spare of 245kV Current Transformer

-

-

-

... More
(i) Complete CT [1 No. each type supplied)

1

-

-

... More
Spare of 145kV Current Transformer

-

-

-

... More
(i) Complete CT (1 No. each type supplied)

1

-

-

... More
Spare of 33 kV Current Transformer

-

-

-

... More
(i) Complete CT (1 No. each type supplied)

1

-

-

... More
(F) C&R panels (similar items as used in the quoted panels)

-

-

-

... More
Bay Control Unit (220 kV Side of offered type)

1

-

-

... More
Bay Control Unit (132 kV Side of offered type)

1

-

-

... More
Bay Control & Protection Unit (33 kV Side of offered type)

1

-

-

... More
Bay Unit (For 220 kV Busbar Protection of offered type)

1

-

-

... More
Bay Protection Unit (Distance for 220 kV Feeders of offered type)

1

-

-

... More
Bay Protection Unit (Line Distance cum Differential for 220 kV Feeders of offered type)

1

-

-

... More
Bay Protection Unit (Distance for 132 kV Feeders of offered type)

1

-

-

... More
Bay Protection Unit (Differential for 220 kV Transformers of offered type Main-I)

1

-

-

... More
Bay Protection Unit (Differential for 220 kV Transformers of offered type-Main-II)

1

-

-

... More
Bay Protection Unit (Differential for 132 kV Transformers of offered type)

1

-

-

... More
Bay Protection Unit (Back-up Overcurrent & E/F of offered type)

2

-

-

... More
Breaker failure relay (numerical type)

1

-

-

... More
Trip circuit supervision relay

4

-

-

... More
Self reset trip relay

2

-

-

... More
Hand reset trip relay

2

-

-

... More
Timer relay

2

-

-

... More
DC supervision relays

2

-

-

... More
Flag relays

2

-

-

... More
Auxiliary relays

2

-

-

... More
Multifunction Panel Meter

2

-

-

... More
Fiber Optic Cable with Connectors

1

-

-

... More
Transducers (Each Type used in the autoamtion system)

1

-

-

... More
Ethernet Switch (of offered type)

1

-

-

... More
(G) Station Transformer

-

-

-

... More
10% of total Transformer Oil quantity in non-returnable drums

1

-

-

... More
HV bushing

1

-

-

... More
LV bushing

1

-

-

... More
Pressure relief device

1

-

-

... More
Tap charger contact

1

-

-

... More
Set of valves

1

-

-

... More
Set of gasket

1

-

-

... More
Silica gel required for five replacements

1

-

-

... More
(H) Surge Arrester

-

-

-

... More
220kV class 198 kV rating LA complete as specified.

1

-

-

... More
132kV class 120 kV rating LA complete as specified.

1

-

-

... More
33 kV Class of 30kV rating LA Complete as specified

1

-

-

... More
2 Nos. Terminal connector of each type as spare

1

-

-

... More
(I) Battery & Battery Charger

-

-

-

... More
220 V & 48 V Type Battery

-

-

-

... More
Spare battery cell without electrolyte

2

-

-

... More
Terminal connectors with bolts & Nuts

2

-

-

... More
Float level indicators

2

-

-

... More
Vent Plugs

2

-

-

... More
220V/ 50V Battery Chargers

-

-

-

... More
Set of Control Cards

1

-

-

... More
Set of relays

1

-

-

... More
Set of contactor

1

-

-

... More
Micro-switches

1

-

-

... More
Filter Capacitors

1

-

-

... More
Thyristor/ Diode

1

-

-

... More
Set of switches

1

-

-

... More
Set of wound resistors

1

-

-

... More
Potentiometers

1

-

-

... More
Fuses of Thyristor with indicators

2

-

-

... More
(J) L.T. SWITCHGEAR :

-

-

-

... More
Relays

1

-

-

... More
CTs AND PTs

1

-

-

... More
Switches/Push buttons and Meters

1

-

-

... More
TPN Switches/MCB

1

-

-

... More
L.T. Breaker spares

-

-

-

... More
a) Spring charging motor

1

-

-

... More
b) Aux. Contact sets

1

-

-

... More
c) Busbar Seal off insulators

2

-

-

... More
d) Arc-chutes

1

-

-

... More
e) Moving contacts

1

-

-

... More
f) Arcing contacts (Fixed/Moving)

1

-

-

... More
g) Springs (Closing/Opening)

1

-

-

... More
h) Closing coil

1

-

-

... More
i) Tripping coil

1

-

-

... More
j) Aux. finger contact

1

-

-

... More
k) Limit switches

1

-

-

... More
l) Jaw contacts

1

-

-

... More
Busbar

-

-

-

... More
a) Busbar insulators

2

-

-

... More
b) Interphase barrier

1

-

-

... More
c) Busbar strip 1mm (Aluminium)

5

-

-

... More
(K) LIGHTING SYSTEM

-

-

-

... More
Single Pole MCB

1

-

-

... More
Triple pole MCB

1

-

-

... More
Fluorescent tube & Starter

2

-

-

... More
a) Choke

2

-

-

... More
b) Bottom Strips

1

-

-

... More
c) Top covers & reflector (if applicable)

1

-

-

... More
d) Holders

1

-

-

... More
e) Complete fittings

1

-

-

... More
Sodium vapour/Mercury vapour Lamps a) Lamp

1

-

-

... More
b) Ballast

1

-

-

... More
c) Condenser/ Igniter

1

-

-

... More
d) Lamp holder

1

-

-

... More
e) Lamp holder

1

-

-

... More
f) Complete fittings

1

-

-

... More
Incandescent lamp

-

-

-

... More
a) Bulbs

1

-

-

... More
b) Holders

1

-

-

... More
c) Complete fittings

1

-

-

... More
Switches and sockets

1

-

-

... More
Junction box

1

-

-

... More
Celing Fan

1

-

-

... More
(L) Clamps & Connectors Set

1

-

-

... More
(M) Fire Protection System

-

-

-

... More
NIFPES System

-

-

-

... More
Fitted Nitrogen Cylinder [48 Lit Water Capacity]

1

-

-

... More
Hose Pipe with Fittings

1

-

-

... More
Heat Sensor Assembly

1

-

-

... More
Fire Survival Cable [sufficient for 1 system]

1

-

-

1

-

-

... More
Limit Switches for Fire Detector

1

-

-

... More
Fire Detector (for NIFPES System)

2

-

-

... More
Thermostat

2

-

-

... More
Heating Element

2

-

-

... More
(N) Isolators

-

-

-

... More
220 kV

-

-

-

... More
Solid core Insulator Stacks (Requirement of one Isolator)

1

-

-

... More
Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered.

1

-

-

... More
Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered

1

-

-

... More
Motor with gear assembly and bevel gear assembly.

1

-

-

... More
Bearings (Requirement of one Isolator)

1

-

-

... More
Current carrying assembly total (Requirement of one Isolator)

1

-

-

... More
132 kV

-

-

-

... More
Solid core Insulator Stacks (Requirement of one Isolator)

1

-

-

... More
Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key interlock for electrical control circuit as per approved schematic --- Each set containing one number of each type and rating as offered.

1

-

-

... More
Limit switches & aux.switches--Each Set containing one no. of each type and rating as offered

1

-

-

... More
Motor with gear assembly and bevel gear assembly.

1

-

-

... More
Bearings (Requirement of one Isolator)

1

-

-

... More
Current carrying assembly total (Requirement of one Isolator)

1

-

-

-

-

-

... More
Solid core insulator Stacks ( Requirement of one Isolator)

1

-

-

... More
Limit switches and auxiliary switches ---Each Set containing one no. of each type and rating as offered

1

-

-

... More
Bearings (requirement of one isolator)

1

-

-

... More
Current carrying assembly 2000A total (requirement of one isolator)

1

-

-

... More
Motor with gear assembly and bevel gear assembly.

1

-

-

... More
Relays, power contactors, MCB’s switch fuses, push buttons and resistors, timers, key inter lock for electrical control circuit as per approved schematic-- Each Set containing one no. of each type and rating as offered

1

-

-

... More
Add: Any other supply item, if any, bidder may require completing the substation as per specification requirements.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.