Rajasthan Police Housing And Construction Corporation Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 26,600Document Cost
₹ 1,180Tender Fee
₹ 500
Summary
Modrenisation Of Visitor Room (mulakaat Kaksh) At District Jail Bhilwara
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_RPHCC_377740_11Bid Award Id
ViewTender No
NIT No. 28 of2023-24MD, RPIDCL, JaipurTender Authority
Rajasthan Police Housing And Construction Corporation Limited ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead.
197.34
2960
15
Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in :Cement Mortar 1:6 ( 1-Cement : 6-Sand).
6.5
22613
3479
Repair to stone masonary in cement sand mortar 1:6 with old and new stone.
30.87
9816
318
Repair to brick masonary in cement sand mortar 1:6 with new brick.
30.87
10927
354
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish :20mm thick .
396.9
80173
202
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete :- New Plastered Surface (three or more coats)
396.9
33339
84
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect
435.23
30030
69
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
94.86
7588
80
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
575
55200
96
Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick ;- 10 mm thick glass
35.9
84616
2357
Extra for providing toughened glass panes instead of ordinary float glass panes in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). :-10 mm
35.9
17950
500
Providing Factory Made 100% Solid WPC (Wood polymer Composite) Board of 18mm thicknesss of required size comprising of virign PVC resin of K Value 58-60 ( Suspemsion Grade), Calcium Corbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk) and Non toxic additives , made from Extrusion process WPC foam sheet Single Extruded ( Inner) with density not less than 550 kg/cbm manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withrawal strength of 1800 N ( Face) & 900 N ( Edge), Minimum Compissive Stength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance of spread of flam of Class A caegory wih Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For KITCHEN CABINET & CUPBOARDS
38.04
62766
1650
Providing & fixing factory made 100% Solid WPC (Wood Polymer Composite) Door Frame 90mm x 45 mm ( Moulded ) Single Rebated,, made from Wood Polymer Composite (Single Extruded Process) material comparising of virign PVC polymer of K Value 58-60 ( Suspemsion Grade), Calcium Corbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk) and Nor toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed srews having minimum frame density of 780 kg/ cbm & manufactured by an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withrawal strength of 2200 N ( Face) & 1100 N ( Edge), Minimum Compissive Stength of 58 N/mm2, Moduus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in postion with SS Dash Fasterns / Hold Fast of reuired dia and lenght, all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company ( Hold Fast or Dash Fastners shall be paid seperately)
210.5
115775
550
Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished seamless type tubes.
2050
223450
109
Supply and installation of Multi Rib Proofing/cladding Sheet Manufacture out of 0.50mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel (as per 150gsm zinc aluminum coated 550Mpa tuekd strength) confirming to IS: 1397/astm A-792 sheet to have wide pens 30mm high NB at 250 centre and centre width of 1020mm sheets be casted with regular modified polyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate made to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. The sheet shall be supplied in cost one length and for a minimum up to 12mts with all scaffolding.
112.5
77512
689
Add extra for 0.80mm TCT (Total Coated Thickness) high tensile Zinc aluminum alloy coated galvalume steel sheet in place of 0.50mm thick
112.5
34880
310.05
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
12
1884
157
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) :-Thermo-mechanically Treated bars (Conforming of relevent IS code
475
36575
77
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
2.43
11989
4934
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :-For area of each slab from 2001 to 5000 Sq.Cm
43.4
44398
1023
Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR
-
-
-
Short point (up to 3 mtr.)
2
718
359
Medium point (up to 6 mtr.)
15
8670
578
Long point (up to 10 mtr.)
9
6948
772
Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
On board
2
714
357
Short point (up to 3 mtr.)
6
1698
283
Long point (up to 10 mtr..)
8
5512
689
Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR
2
1160
580
Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR.1200 mm Sweep BEE 3 Star rated (service value =5.0 to 5.5
8
17520
2190
Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
8
3184
398
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm
16
7872
492
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR :-12 Way (12+2)
1
2590
2590
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSR :- Double pole MCB(With B/C curve tripping Characteristics) :-6 A to 32 A rating
2
1132
566
Single pole MCB (With B/C curve tripping Characteristics) :-6 A to 32 A rating
8
1496
187
Providing & Fixing of 240/415 V factory fitted RCBO with overload,short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provisionfor pad lock, min. Electrical operation 10,000 upto 63 A rating ,minimum phase termination capacity of 35sq.mm. , IP 20 contactprotection with existing distribution board / sheet including makingconnections, testing etc. as required. OEM shall have submit NABL/ CPRI / ERDA accrediated lab type test reports & All as per preapproved by Engineer in charge. For additional technicalparameters of product / work refer Annexure 'A' attached with thisBSR :-Two pole 100/300mA sensitivity :-6A-32 A rating
1
3004
3004
Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR
-
-
-
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
60
7320
122
2 x 2.5 sq. mm. + 1x1.5sqmm
100
8100
81
2 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
25
4250
170
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure 'A' attached with this BSR :-25 mm
50
2800
56
Providing & Fixing of of Double ball bearing, copper wounded capacitorstart single phase metallic blade fresh air fan, in existing openingincluding cost of hardware , flexible 3 core copper conductor ,makingconnections, testing etc. as required. All as per pre approved by Engineerin charge. For additional technical parameters of products/ work , referAnnexure "A" attached with this BSR :-300 mm sweep
2
3644
1822
S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVCtrunking along with accessories like coupler, inner, outer, elbow,square box, tee, end cap etc. on surface with screws, expansionfasteners as required. For additional technical parameters of product /work refer Annexure 'A' attached with this BSR :-50 mm x 50 mm
20
4480
224
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC,UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable asper latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should bebalancedtwisted in pairs, seperated by a cross-member fluted pair divider & protected by PVCJacket. Certified performance in a 4-connector configuration upto 100 Mtrs channelrequirements & transmission frequencies up to 250 Mhz. in existing MS/PVCConduits/casing capping including making connections to Information outlets and PatchPanels with jack & ferruling at both ends for identification with necessary tools for
punching, stripping, crimping and testing etc as required complete in all respect. All as perpre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
220
10780
49
Supply and installation of high tensile low carbon steel rod molecularly bonded with 99.9 % Copper thickness (250 microns) and confirming to UL 467, IS/IEC 62561-2 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole (b) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 30 KA for withstanding 1 second .To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & high conductivity in nature with carbon as a major content as per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt (d) Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.(e) Test certificates for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . :-25 mm thick and 3 Mtr. Long
1
7955
7955
Supply & Laying following size earth wire in horizontal or vertical runinground/surface/recess including riveting, soldering, saddles, makingconnection with GI/Cu purity purity 95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached with thisBSR :-8 SWG copper Wire
15
2220
148
Evaluation Notes How It Works ?