Rajasthan Police Housing And Construction Corporation Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan Police Housing And Construction Corporation Limited Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date27 Feb 2024
Closing Date11 Mar 2024
Tender Amount₹ 7,55,000 
Notes
Download

Costs

  • EMD

    ₹ 15,100
  • Document Cost

    ₹ 590
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.

-

-

-

... More
75mm thick with 20mm thick nominal size aggregate.

8

3664

458

... More
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete

-

-

-

... More
For area of each slab from 2001 to 5000 Sqcm

12

12024

1002

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:

-

-

-

... More
New work (two or more coats) over and including scrapping and priming coat with cement primer.

59

4425

75

... More
Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only)

59

236

4

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Two or more coats on new work

11

759

69

... More
ELCTRICAL WORK

-

-

-

... More
Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit &it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick HotDipped Galvanized Modular Box with earth terminal, 10A Modularswitch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3way connector, screws, making connections, testing etc. as required.For specification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 Foradditional technical parameters of product / work refer Annexure 'A'attached with this BSR

-

-

-

... More
Short point (up to 3 mtr.)

10

3590

359

... More
Medium point (up to 6 mtr.)

20

11560

578

... More
Long point (up to 10 mtr.)

30

23160

772

... More
Description Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
On board

10

3570

357

... More
Supplying and fixing of power plug point with Modular accessories as perPWD specification for electrical Works, on hot dipped galvanized modularbox of 1.2 mm thick with earthing terminal/connector on surface or inrecessed with suitable size of modular face place with grid plate and coverplate including cost of ISI marked modular 16 amp. Switch (IS :3854) and6/16 amp. socket outlet (IS:1293) making connection , testing , etc. asrequired. For specification of Wiring accessories refer Chapter E - 07related item & For additional technical parameters of product / work referAnnexure 'A' attached with this BSR

5

2900

580

... More
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
1170mm(+/-10%) LED batten with min. lumen output 2200 lm

20

9840

492

... More
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheetnot less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC61439- 1 & 3, powder painted complete with reversible door (fordouble door DB only )100 amp. insulated copper bus bar/shortinglink , copper neutral link, copper earth link , color codedinterconnecting wire set of suitable rating and dinbar,maskingsheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc.as required. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work referAnnexure 'A' attached with this BSR

-

-

-

... More
Metal door (single phase) IK-09 and IP-43 with Metal end box

-

-

-

... More
8 Way (8+2)

1

2184

2184

... More
12 Way (12+2)

1

2590

2590

... More
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fittedin existing distribution board/sheets, minimum electrical operation20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A &above rating including making connections, testing etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab typetest reports & All as per pre approved by Engineer in charge. Foradditional technical parameters of product / work refer Annexure'A' attached with this BSR

-

-

-

... More
Double pole MCB(With B/C curve tripping Characteristics)

-

-

-

... More
40 A rating

-

-

-

... More
6 A to 32 A rating

3

1698

566

... More
Single pole MCB (With B/C curve tripping Characteristics)

-

-

-

... More
6 A to 32 A rating

18

3366

187

... More
Four pole MCB (With B/C curve tripping Characteristics)

-

-

-

... More
50/63 A rating

1

1745

1745

... More
Supplying and drawing FR PVC insulated & unsheathed flexible copperconductor as per PWD specification for electrical Works with ISImarked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire shouldbe made from 99.90 % purity copper, class 5 stranding in acc. toIS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping makingconnections with Copper Lugs of suitable size, Ferrules,testing etc. asrequired. OEM Must have its own in house NABL lab setup for alltesting facilities for wires. For additional technical parameters ofproduct / work refer Annexure 'A' attached with this BSR

-

-

-

... More
2 x 2.5 sq. mm. + 1x1.5sqmm

120

9720

81

... More
3x 1.5 sq.mm

50

3150

63

... More
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.

80

9760

122

... More
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P -III ) PVC conduit along with ISI marked (IS:3419-1988) accessories asrequired in recess including cutting the wall, covering conduit andmaking good the same as required. For additional technical parametersof product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
20 mm

20

800

40

... More
25 mm

70

3920

56

... More
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
6.0 Sq. mm

-

-

-

... More
3 core

80

11680

146

... More
Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb inexisting holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf0.95 , CRI 70, minimum life time of minimum 25000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As perANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouse NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate /Report from OEM shall be submitted. All as per pre approved by engineer in charge . foradditional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR

-

-

-

... More
9 Watt

10

1150

115

... More
Providing & Fixing of Heavy duty capacitor start, copper wound Doubleball bearing 900/1400 RPM single phase Exhaust fan conforming toIS:2312 ISI marked in existing opening including making connectionstesting etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure"A" attached with this BSR .

-

-

-

... More
300 mm sweep(900/1400 RPM)

1

3175

3175

... More
Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 forwater supply suitable for submersible & jet pump with requiredfittings ie socket, elbows, tee etc. complete in all respect. All as perpre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached withthis BSR

-

-

-

... More
for vertical installation

-

-

-

... More
75 mm OD 6 kg / cm2

30

5880

196

... More
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB)made of flame retardent & heat resistant material having followingcurrent rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L &S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face andcentralised adjustable, trip free mechanisum, true contact positionindicator, line load interchangeability, designed for both horizontal &vertical mounting without any adverse effect on electrical performance,suitable for operation upto 55 degree and without derating upto 40degree, pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breakingcapacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock &rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificatebefore execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR

-

-

-

... More
4 pole MCCB With Thermal Magnetic release

-

-

-

... More
up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

3

21336

7112

... More
125 Amp , 25 kA, adjustable O/L & adjustable S/C setting,

1

8391

8391

... More
Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequencymeter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVCinsulated copper conductor with PVC sleeves / channel etc. as required. All as perpre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485

1

6272

6272

... More
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the groundlevel with 20mm dia. G.I. 'B' class watering Pipe ,including all accessorieslike nut, bolts, reducer, nipple, wire meshed funnel, and Heavy dutyweather proof poly-propylene earth pit chamber with lockable Jam freelid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.andembodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5 ohms or less asrequired & must record by engineer in charge during site visit and ensureto enter in measurment book.All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

1

5733

5733

... More
Supply and installation of high tensile low carbon steel rod molecularlybonded with 99.9 % Copper thickness (250 microns) and confirming toUL 467, IS/IEC 62561-2 of following size and length and as per pointmentioned (a), (b), [c), (d), (e) below :-(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole

-

-

-

... More
(b) filled with anti corrosive conductive compounds with the permanentsealings at both the ends, CPRI/ ERDA tested with RMS capacity ofminimum 30 KA for withstanding 1 second .To ensure the moisturecontent and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for3000mm of resistance lowering earth enhancement material shall beused as a backfill compound. The compound shall be tested form NABLacredeated lab for low resistivity ( less than 0.12 Ohm - meter ) & highconductivity in nature with carbon as a major content as per referance ofIS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 withlatest amendemnts

-

-

-

... More
Connect the rod with copper Strip/Conductor/Wire with suitableclamp made from tinned copper and SS 304 Bolt Place Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.

-

-

-

... More
Testing of earth resistance for value of 5 ohms or less as required &must record by engineer in charge during site visit and ensure to enter inmeasurment book.

-

-

-

... More
Test certificates for confirming above standards from OEM ismandatory. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work ,refer Annexure "A" attached with this BSR .

-

-

-

... More
25 mm thick and 3 Mtr. Long

1

7955

7955

... More
Supply & Laying following size earth strip in horizontal or vertical run insurface by means of Earth strip DMC Insulator including riveting/soldering/ welding, Jointing shall be done by overlapping and with 2 setof Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at50cm making connection etc. as required.All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR .

-

-

-

... More
25mm x 5mm copper strip

15

23265

1551

... More
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All asper pre approved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
8 SWG copper Wire

15

2220

148

... More
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressurediecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beamangles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number havingefficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System levelLuminaire efficacy =125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff@=300 V AC and Auto resetting Safety .Power Factor 0.95 , THD(I) 10% , driver current =750mA.driver should be Phase to phase protectionof 440 V for 4 Hrs. Electrical Connector , Surge Protection Min=4KV internal and 10KV external butinside driver compartment, System life of 50000 Burning hourswith 70% ofInitialLumensmaintained,CRI70andCCT5700K355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbe IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LEDfixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shallbe submitted. All as per pre approved by Engineer in charge. Foradditionaltechnical parameters ofproducts/ work , refer Annexure "A" attached with this BSR

-

-

-

... More
High Power LED Flood Light Minimum lumen output 14800 lm

2

17744

8872

... More
High Power LED Flood Light Minimum lumen output 22400 lm

4

53200

13300

... More
SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ freestanding floor mounted dust and vermin proof compartmentalised cubical panelas specifications and Other parameters required as per point (a) ,(b), (c),(d), (e),(f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments havingconcealed hinged type doors with key type lock with / without detachableextension type structure. Removable 3 mm. thick sheet steel gland plates withappropriate size of knockouts for cables shall be provided

5

29875

5975

... More
complete panel shall undergo a process of degreasing, Water rinsing,Activation, derusting, pickling in acid bath, phosphatising & shall be subjected tonine tank process and then Powder coated with approved shade of minimum 70microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.

-

-

-

... More
Interconnection between bus bar and switchgears /cable shall be rigidlysupported and made out by flexible copper wires (up to 63 amp ) and by solid busbbar (63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to widthof bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral busbar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire fornterconnection between Main busbar and Switchgear is to be Paid Extra )

-

-

-

... More
Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not bepermitted. Each terminal block shall be one piece moulded, barrier type, 650 voltgrade, complete with washers, heads, studs with two nuts and identification stripsand shall have adequate continuous current rating. For tap-offs, adjacentterminals with shorting strips shall be used. 10% Spare terminal blocks shall beprovided. Wire identification on marking strip shall correspond to the designationof the wiring diagrams. All wire terminals on the equipment shall also be markedwith designation corresponding to those of the wiring diagram.

-

-

-

... More
All wiring shall be enclosed in plastic channels and neatly bunched and closedin metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging

-

-

-

... More
Floor mounted panel shall be mounted on Base frame of ISMC channel size 100x 50 x 5 mm ( to be paid Extra )

-

-

-

... More
Tests: The insulation resistance (with 1000 V Megger) and High voltage Powerfrequency test (by applying a voltage of 2.5KV for one minute) shall be measuredbetween phases, between phase and neutral and between phase and earth. bothbefore and after high voltage power frequency test. The insulation resistance shallnot be less than three megaohm. CT Secondary current injection test shall also becarried out.

-

-

-

... More
only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted Allas per pre approved by Engineer in charge. For additional technicalparameters ofproducts/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028)bus bar by means of SMC / DMC type insulator with standard short circuitwithstand capacity , high tensile nuts and bolts spring washers in existing panelincluding bending , cutting in required shape and size and colour coding with heatshrinkable PVC sleeves. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure "A"attachedwith this BSR

-

-

-

... More
Electrolytic grade Aluminium bus bar 6010 grade

3

1626

542

... More
Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947withintegral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tinplated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .

-

-

-

... More
Red/yellow/Green colour

3

510

170

... More
P/Laying ISI marked P.V.C. insulated submersible cable confirmingto(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemade from 99.90 % purity copper, stranding in acc. to IS:8130/IEC60228 for lower watt loss , oxygen free for less chances of oxidization,insulation PVC type A/C/D , flame retardant as per IS 10810-53, betteramperage rating as per IS:3961 part 5, existing pipe / open trench /Cable tray / on surface including making connection etc. as required.For additional technical parameters of product / work refer Annexure'A' attached with this BSR

-

-

-

... More
1.5 Sq.mm 3 core flat / Round Mtr. 92.0

10

920

92

... More
Santary work

-

-

-

... More
P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:

-

-

-

... More
Exposed on wall

-

-

-

... More
15 mm dia nominal bore

-

-

-

... More
'B' Class

15

3450

230

... More
25mm dia nominal bore

-

-

-

... More
'B' Class

44

15840

360

... More
P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.

-

-

-

... More
15mm dia nominal bore

-

-

-

... More
'B' Class

24

4560

190

... More
25mm dia nominal bore

-

-

-

... More
'B' Class

40

11120

278

... More
P & F Pilllar Cocks (IS :8931 : 1993 Mark) of superior quality and approved make:

-

-

-

... More
C.P. Pillar cock, 15 mm dia nominal bore

4

3116

779

... More
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:

-

-

-

... More
Synthetic Material(PTMT) bib cock of approved quality/ make, nominal bore, 15mm, 86 mm long.

13

2431

187

... More
(-do-) Fancy Type, 122 mm long.

8

1856

232

... More
P & F Ball Cock (IS :1703 Mark) with Rod & P.V.C. Ball complete :

-

-

-

... More
Brass wt.Not less than 400 gm, 20mm.

6

2232

372

... More
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :

-

-

-

... More
Gun-metal 15mm nominal bore.

6

1362

227

... More
(-do-) 25mm nominal bore.

6

3174

529

... More
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:

-

-

-

... More
1000 (-do-)

5

39205

7841

... More
Hoisting Charges for each floor :

-

-

-

... More
For items 2.26.5 to 2.26.8

5

785

157

... More
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :

-

-

-

... More
15mm dia nominal bore

5

505

101

... More
25mm dia nominal bore

5

820

164

... More
Labour charges for Removing S.W. pipes including breaking of joints & bed concrete, stacking of useful material at site within 50 mtr. Lead and disposal of unserviceable material within 0.5 Km. lead:

-

-

-

... More
100 & 150mm dia pipe

90

2070

23

... More
Labour charges for Removing S.W. pipes including breaking of joints & bed concrete, stacking of useful material at site within 50 mtr. Lead and disposal of unserviceable material within 0.5 Km. lead:

-

-

-

... More
100 & 150mm dia pipe

74

1702

23

... More
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.

-

-

-

... More
110 mm dia

31

8742

282

... More
160 mm dia

35

16205

463

... More
Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc.

-

-

-

... More
PVC pipe 110 mm dia

31

10075

325

... More
PVC pipe 160 mm dia

35

14875

425

... More
Bend 87 .5

-

-

-

... More
110mm dia

3

483

161

... More
160 mm dia

3

531

177

... More
Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site.

14

4004

286

... More
Mechanised Cleaning of sewer line of diameter upto 200mm with the help of trolley mounted electrical driven machine having flexible steel springs of length 20ft. Each which are rotated with the help of electric motor and clutch assembly.

-

-

-

... More
Internal Size 0.45 m x 0.45 m

3

34947

11649

... More
Internal Size 0.90 m x 0.90 m

1

40403

40403

... More
Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-

-

-

-

... More
Size 400 x140x150 cm.(for 50 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.

2

119720

59860

... More
Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:

-

-

-

... More
Size 300 Cm. dia outside & 300 Cm. depth .

2

48270

24135



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.