Rajasthan Housing Board Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Rajasthan Housing Board - RHB Tender

Works
Eprocure
Opening Date17 Jun 2021
Closing Date7 Jul 2021
Tender Amount₹ 2,76,19,000 
Notes
Download

Costs

Summary

Item 3 Construction Of Water Supply Scheme For City Level Park Mansarovar Jaipur

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
75 mm dia

3225

-

-

... More
110 mm dia

2375

-

-

... More
125mm dia

65

-

-

... More
160 mm dia

1917

-

-

... More
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932 (Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 100 mm dia Class PN 1.0

7

-

-

... More
Providing and fixing of reinforced Ferro-Cement drain covers designed for 'A' class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate, Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. Standard Size 1500x600mm (125mm thick) for span 701 to 1200mm

206

-

-

... More
Construction of RCC Clear Water Reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.

-

-

-

-

-

-

... More
The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete.

-

-

-

... More
Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below:

-

-

-

... More
For foundation on SBC 7 MT/sqm applicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%

-

-

-

... More
For foundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%.

-

-

-

... More
For foundation on SBC more than 18MT/sqm rates decreased by 5 %

-

-

-

... More
Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones.

-

-

-

... More
Rates for RCC Rectangular Flat Slab CWR, SBC 10T/sqm, seismic zone II .

-

-

-

... More
up to100 KL capacity

300000

-

-

... More
Water Tank-1 (75 KL - 2 Nos)

-

-

-

... More
Water Tank-2 (75 KL - 2 Nos)

-

-

-

... More
up to150 KL capacity

460000

-

-

... More
Water Tank-3 (115 KL - 2 Nos)

-

-

-

... More
Water Tank-4 (115 KL - 2 Nos)

-

-

-

... More
Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect. Pum House-1 (10.0 m x 8.0 m x 3.3 m) Pum House-2 (10.0 m x 8.0 m x 3.3 m) Pum House-3 (4.5 m x 9.8 m x 3.3 m) Pum House-4 (4.5 m x 9.8 m x 3.3 m)

355

-

-

... More
Provision for O&M of TWs, Rising Main, Reclaimed (STP treated) water supply pipelines, raw water supply pipelines, fresh water supply pipelines. Maintanance Team for M&R of Pipe line network DI / HDPE Pipe including 7 Nos. tube well for repair and maintenance complete job

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.