If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 4,46,840Document Cost
₹ 3,540Tender Fee
₹ 2,360
Summary
Item-2 Water Supply Sewerage And Rain Water Harvesting System For S S Residency At Sector -19 Pratap Nagar Jaipur Including One Year O And M Work.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RHBCE_384148_1Bid Award Id
ViewTender No
ACE-I_16/2023-24Tender Authority
Rajasthan Housing Board ViewPurchaser Address
-Website
http://http://urban.rajasthan.gov.in/rhb
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
150 KL Capacity
150000
-
-
... More
250 KL Capacity
250000
-
-
... More
Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following poery, tools, and tackles required, construction of temporary works as
11.0 KW (15 HP)
4
-
-
... More
SITC STAR DELTA Starter type LT Panel of following rating: all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries (Insulators, Acrylic Sheet, Backlight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Neutral Links , Spiral , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminium Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge.
STAR DELTA STARTER 11.0 KW (15.0 HP) - : For 2 motors (1 W+ 1S) I/C - MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm (0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3), Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1) (1), Control MCB 6A SP10 KA C Curve (3) and O/G- MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Preventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2)
2
-
-
... More
Construction of chamber in all type of soil with 230 mm thick masonry with CM 1:4 m 15 cm thick C.C. 1:3:6 in foundation, 20mm thick insider plaster in Cm 1:4, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. with precast RCC main hole cover with frame as per approved drwaing & direction engineer- in- charges.
Inside size 600X 600 mm depth upto 1.5 M
25
-
-
... More
Construction of Pump house of brick/ stone masonry of required size suitable for installation of maximum 4 no. Monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
58
-
-
... More
Construction for RCC Sendimentation Tank (1800 x 1800 mm) of following size in all tyoe of soils with 150 mm thick RCC wall, basic of raft with 300 mm thick Dry stone soling, Under 100mm thick C.C. M10 grade norminal mix in foundation 20mm thick insider plaster with 1:4 Cement sand motor finished with floating neat cement, 150 mm thick RCC slab as per approved Drawing. This work including Earth work man hole cover rectangular shape 600 x 450 mm precast RCC manhole cover LD-25 etc. complete as per drawing & specifications including disposal of surplus earth within a lead of 50 mtr.
Inside size 1800 X 1800 mm
4
-
-
... More
Providing, Installation, Testing and Commissioning of ULTRASONIC LEVEL TRANSMITTER for Water Application : Principle : Time of Flight / Sensor MOC PP / Process Connection 1 1/2 inch BSP or 2 inch BSP Threaded type / Power Supply: 24 V DC / Output: 4- 20mA / Display: Integral display for programming and Display Reading / IP 66 0 - 8 MTR
(At over head tank above building including all items)
6
-
-
... More
Operation and maintenance of scheme including reparing of pipe line using required material, reparing of motor pump & electric feeder panel at his own cost etc. complete in all respect for one year.