Public Works Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Works Department - PWD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date24 Mar 2023
Closing Date12 Apr 2023
Tender Amount₹ 42,08,99,000 
Notes
Download

Costs

  • EMD

    ₹ 84,17,980
  • Document Cost

    ₹ 20,000
  • Tender Fee

    ₹ 2,500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earthwork in excavation for roadway in soil, including stacking / disposal of surplus Material exclusive of compensation of earth By Hydraulic Excavator CK-90 of 0.9 cum bucket capacity and tipper with disposal upto 1000 mtrs.

46291.27

1481320

32

... More
Construction of embankment with approved Materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted by vibratory roller 8-10 tonne to meet requirement of Tale 300-2 as per MoRTH specification : Clause No. 305

45709.09

1645527

36

... More
Construction of embankment with approved Material obtained from borrow-pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of Table 300-2 including cost of compensation for earth taken from private land with lead upto 1 km as per MoRTH Specification : Clause No. 305.

213123.92

24935498

117

... More
Construction of sub-grade and earthen shoulders with approved Material obtained from borrow-pits with all lifts and leads, transporting to site, spreading, grading to require slope and compacted by vibratory roller 8-10 tonne to meet requirement of Table 300-2 as per MoRTH specification : Clause No. 305.

50587.35

5210497

103

... More
Providing, laying and spreading and compacting specified graded crushed stone in sub-base course including premixing the Material at OMC in mechanical mixer (Pug mill), carriage of mixed Material, laying in uniform layers with Motor Grader, F.E. Loader, on a prepared surface and compacting with Vibratory Compactor to achieve the desired density including all Material, labour, machinery, lighting barricading and maintenance of Driversion complete. (MoRTH specification clause 401). with all lead & lift

24244.38

23856469

984

... More
Providing, laying, spreading and compacting crushed graded stone aggregate as per Table 400-10 & 400.11 to Wet Mix Macadam specifications including premixing the Material with water to OMC in mechanical mixer (Pug mill) as per design mix, carriage of mixed Material by tipper to site laying in uniform layers, with motor grader/F.E. loader/Paver Finisher, in sub-base/base course on a well prepared under-base and compacting with Vibratory Roller to achieve the desired density including lighting, guarding, barricading and maintenance of Driversion etc. (MoRTH specification : Clause 406). with all lead & lift

46894.89

57962084

1236

... More
Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS:8887 & manufacturer’s specifications @7 kg/10 sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification : Cl. 502, 112

209441.7

6890631

32.9

... More
Providing and applying tack coat on the prepared surface, with bitumen emulsion as per IS:8887 & manufacturer’s specifications @0.25 kg/sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification Cl. 502, 112.

215370.45

2692130

12.5

... More
Providing and laying Bituminous Macadam on prepared surface with specified graded crushed aggregates as per Table 500-7, Grading-2, for base/binding course including loading of aggregates with F.E. loader and heating & mixing of stone aggregate and bitumen (including cost of anti-stripping compound, wherever required) in hot mix plant (40-60 TPH), transporting the mixed Material in tipper to paver and laying mixed Material with paver finisher to the required level and grade, rolling by power roller and vibratory compactor as per Cl. 501.6 & 501.7 to achieve the desired density (approved by the department) excluding cost of primer/tack coat. [MoRTH Specification : Clause 504, 112].50/75mm compacted thickness with 3.4% bitumen VG30 grade

10769.31

59274282

5504

... More
Providing and applying tack coat on the prepared surface, with bitumen emulsion as per IS:8887 & manufacturer’s specifications @0.2 kg/sqm with a self propelled or towed bitumen pressure sprayer equipped for spraying the Material uniformly at specified rates and temperatures (including cleaning of road surface) as per MoRTH specification Cl. 502, 112.

215370.45

2304463

10.7

... More
Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed aggregates as per Table 500-23, heating bituminous binder @ 14.6 kg/10 sqm and aggregates in Hot Mix Plant (including cost of anti-stripping compound, wherever required), transporting the mixed Material with tipper and laying with paver finisher to the required level and grade, rolling with power roller, 8-10 tonne, but excluding cost of tack coat and seal coat with lead for mix of Material 1 km (MoRTH specification : clause 510, 112) In Hot Mix Plant 40-60 TPH, including loading of aggregates with F.E. loader bitumen VG30 grade

215370.45

22010859

102.2

... More
Providing and applying Premixed Seal Coat type “B” comprising of thin application of fine aggregate (0.06 cum per 10 sqm) premix with (6.8 kg per 10 sqm) bitumen binder (including cost of anti-stripping compound, wherever required) in mini hot mix plant 6-10 TPH, and laying with paver finisher and rolling with power roller 8-10 tonne, including all lead of mix Material (MoRTH specification : clause 511). Bitumen VG30 grade

215370.45

8205614

38.1

... More
PART "B" : C.C WORK

-

-

-

... More
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock pilling at designated locations and disposal of dismantled Materials upto a lead of 1000 mtrs. stacking serviceable and unserviceable Materials separately. (MoRTH specification : Clause 202)

1224

1094256

894

... More
Providing, laying and spreading and compacting specified graded crushed stone in sub-base course including premixing the Material at OMC in mechanical mixer (Pug mill), carriage of mixed Material, laying in uniform layers with Motor Grader, F.E. Loader, on a prepared surface and compacting with Vibratory Compactor to achieve the desired density including all Material, labour, machinery, lighting barricading and maintenance of Driversion complete. (MoRTH specification clause 401). with all lead & lift

6409.53

6306977

984

... More
Dry lean cement concrete sub - base. Construction of dry lean cement concrete 1:3:6 sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trail length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver compacting with 8-10 tonne vibratory roller, finishing and curing as per MoRTH specification : Clause No. 601, 112.

6602.13

18822672

2851

... More
Providing and Laying un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures and vacuum processing pump as approved, curing compound, finishing to lines and grades as per drawing as per MoRTH Specification : Clause No. 602, 112. Using Cement concrete M-30 pavement Grade

13920.5

80905946

5812

... More
Providing and fixing of precast concrete interlocking blocks of 80mm thick (M-30 Grade) manufactured from fully computerized automatic stationery hydraulic vibto perssed machine & full computerized automatic batching plant of class A-I as per BS: 6717-2001. The CC interlocking paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compected sub base as defined. The work includes earth work in cutting of B/T road, cutting of WBM road and disposal of unserviceable Material with all leads & lifts and stacking of serviceable Material complete job is to be executed as per the instructions of Engineer-in- charge. The rates to be inclusive of all lead, lifts & taxes General specification of Blocks:

4050

2531250

625

... More
Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900).300 mm dia

400

484800

1212

... More
PART "C" FURNITURE WORK

-

-

-

... More
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.5th kilometre stone (precast)

11

31768

2888

... More
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.Ordinary kilometer stone (precast)

50

86350

1727

... More
Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.Hectometer stone (precast) . 200 m stone (precast)

204

100572

493

... More
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor.Regulatory sign boards of 90 cm Triangle. Size 90 cms. Triangle

110

364980

3318

... More
Providing and Fixing of Retro Reflectorised 600 x 800 mm Facility sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor.Regulatory sign boards of 60 x 80 cm Rectangle. Size 60 x 80 cms. Rectangle

32

95104

2972

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing

22.5

92790

4124

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing

43.2

323222

7482

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.

12985

6622350

510

... More
Raised Pavment Marker ( Cats Eyes): Supplying and Fixing of Molded Shank Raised Pavement Markers made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 – DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 100 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 700 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendation and complete as directed by the engineer. The contractor shall submit 2 years pre qualified warranty certificate from the manufacturer for satisfactory field performance during the time of bid submission

3250

604500

186

... More
Providing and Erecting typical Citizens Information Board as per approved drawing & specification of MoRD, made of two MS Sheet of 1.6 mm thick each of size 900 mm × 750 mm stiffened by angle iron 25 mm ×25 mm × 3 mm all around the plate and plates fixed on frame of 75 mm dia pipe of 12 SWG sheet (vertical post 3050 m with angle holdfasts and horizontal member 900 mm) to be joined by 5 mm thick MS plate at 12 places (65 × 50 mm) duly embedded in cement concrete M-15 grade of block of 600 mm × 600 mm × 750 mm size below ground level as per enclosed drawings & as directed by Engineering - In-Charge. All MS will be stove enameled on both side, Lettering, figuring and border will be with ready mixed synthetic enamel paint of superior quality in required shade and colour etc. complete in all respect. All sections of framed post and steel tube will be painted with primer and two coat of epoxy paint as per drawing and as per MoRD specification.

10

83000

8300

... More
Providing and Fixing of Retro Reflectorised 300 x 900 mm Hazard Marker sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor Regulatory sign boards of 30 x 90 cm Rectangle. Size 30 x 90 cms. Rectangle

82

232060

2830

... More
Providing and Fixing of Retro Reflectorised 600 x 500 mm Chevro sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 2 mm thick Al /4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm - 3 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor Regulatory sign boards of 60 x 50 cm Rectangle. Size 60 x 50 cms. Rectangle

105

309750

2950

... More
Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control Over 10 cm in width

350

41300

118

... More
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810

200

564000

2820

... More
Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans Truss and Vertical Support

6

368652

61442

... More
Overhead Signs Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plansAluminium Alloy Plate for Over Head Sign

43.2

24278

562

... More
Providing and fixing high intencity retro reflective type-iv sign plate made out of 2mm thick aluminium sheet face to be fully covered with blue / green high intencity grade retro reflective sheet and logo / matters, border made of with similier type of white sheeting etching treatement of aluminium sheet, the black side is to be painted with epoxy grey paint. The plate is to be fixed on 40x40x5 mm angle iron frame with help of aluminium rivets.

43.2

347155

8036

... More
PART "D" : C. D. WORK

-

-

-

... More
Earthwork in excavation in foundation trenches etc. in drains and channels etc. not exceeding 2m depth, including dressing of bottom and sides of trenches, stacking the excavated soil 3m clear from the edge of excavation including disposal of surplus soil as directed within a lead of 1000 metres (MoRTH specification : clause 301, 304). Ordinary soil

1970

139870

71

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700].Cement concrete 1:3:6 mix with stone aggregate 40 mm crusher broken.

297.46

1035755

3482

... More
Providing and filling in foundation trenches and at the back of abutment wing walls etc. and below pipe bed in layers not exceeding 150 mm thick including watering and compacting including all leads and lifts. Filter media behind abutment wing walls and return walls (MORTH sp. Clause 2505)

311.57

190992

613

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. In ordinary soil [MoRTH Specification : clause 301] In Hard Rock [MoRTH Specification : Clause 301, 302, 303]. Blasting Prohibited

638.22

215718

338

... More
Providing and laying Plain Cement Concrete M-15 mix with stone aggregate 20mm nominal size mechanically mixed and vibrated in foundation upto a depth of 1.50 below ground level and or 1.50mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700]

2173.04

8900771

4096

... More
providing and laying plain cement concrete M15 mix stone aggregate20mm nominal size mechanically mixed and vibrated . In foundation upto a depth of 1.50 m below ground level and or 1.50 m above ground level

443.12

1815019

4096

... More
Providing and laying Reinforced cement concrete pipes NP-4 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 1000mm dia

25

134600

5384

... More
Providing and filling in foundation trenches and at the back of abutment wing walls etc. and below pipe bed in layers not exceeding 150 mm thick including watering and compacting including all leads and lifts Selected granular Material in filling ( MORTH sp. Clause 2200

199.68

83865

420

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. With 20mm nominal size aggregate. By using concrete mixer.R.C.C. M-20 grade

474.12

2162935

4562

... More
Providing and laying Reinforced cement concrete pipes NP-4 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 1200mm dia

925

6649825

7189

... More
Providing and laying Reinforced Cement Concrete M-20 mix with stone aggregate 20 mm nominal size mechanically mixed and vibrated for bed plates excluding steel reinforcement but including centering and shuttering, laid in position. (MoRTH specification : clause 1000/1700)

12.92

62326

4824

... More
Painting with superior grade enamel apint of approved quality to give an even shade including writing, littering, figuring etc. complete as per IRC standards of :Number of bridge & culvert, (all four sides). New Work ( Three Coats )

12

612

51

... More
Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified

33

89694

2718

... More
Reinforced cement concrete M-30 mix with stone aggregate 20mm nominal size mechanically mixed and vibrated for reinforced concrete work in slab in superstructure at any level excluding steel reinforcement, but including centering and shuttering laid in position (MoRTH specification : clause 1000/1700).

45.9

263190

5734

... More
Structural cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification. Design mix concrete – [MoRTH Specification : Section 1500 & 1700]. RCC in M-25 grade, including form work. For height between 5m and 10m

80.24

408180

5087

... More
Drainage spout with GI pipe 100mm dia and GI bolt 10mm dia with galvanized MS flat clamp complete as per drawing and Technical Specification

6

8790

1465

... More
Providing and fabricating Steel reinforcement for RCC works including cutting, bending, placing in position and binding complete including cost of binding wire. (MoRTH specification : Clause 1000/1600). HYSD bars.

13.56

1207857

89075

... More
Reinforced cement concrete wearing coat M-30 grade at any level including formwork and reinforcement complete as per drawing and technical Specification. [MoRTH Specification : Clause 2204, 1500 & 1700].

7.66

72210

9427

... More
Providing and fixing premoulded bitumen joint filler at any level, for expansion joints including the cost of sealing compound and priming coat. (MoRTH specification : clause 2600). 25mm wide

45.9

550

12

... More
Structural RCC/PSC upto a height of 5 mtr. for reinforced concrete in superstructure complete including steel formwork, scaffolding etc. As per drawing and technical specification. Design mix concrete. [MoRTH Specification : 1500 & 1700]. RCC M-30 grade Solid slab superstructure

352.73

1980226

5614

... More
Providing and laying Dry boulder pitching in flooring at all levels (MoRTH specifications : clause 2500).

28.95

15835

547

... More
Providing and laying HYSD bar reinforcement at any level in superstructure complete as per drawing and technical Specification. [MoRTH Specification : Section 1600]

33.23

3006185

90466

... More
Sand Asphaltic wearing coat, with 5% binder at any level of 50 mm compacted thickness (in two layers, 25mm thick) complete excluding tack coat as per drawing and technical specification. (MoRTH specification : clause 520).

25.5

63495

2490

... More
Providing and Laying PCC M-15 grade leveling course below approach slab complete as per drawing and technical specifications. [MoRTH specification : 2700]

10.53

33359

3168

... More
Reinforced cement concrete M-30 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications. [MoRTH specification : 1500, 1600, 1700, 2704]

21.06

177893

8447

... More
Providing, laying and fixing of Filler Joint Providing and fixing 20mm thick Compressible Fibre Board in expansion joint complete as per drawing and technical specification in MoRTH specification : clause 2605.

84.15

63701

757

... More
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 ltr. for 2 sqm complete in all respect. [MoRTH specification : 800]

1127.5

56375

50

... More
Providing and laying reinforced cement concrete grade M- 30 design mix railing complete as per drawing and technical specification. [MoRTH Specification : 2703, 1500, 1600 & 1700]. Cast in situ.

244

351604

1441

... More
Supply of flood gauge (water gauge) as per IRC 67 standard 200cm long fixed on angle iron posts 50×50×6mm 2.6m long

4

5532

1383

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. In ordinary soil [MoRTH Specification : clause 301] BY MECHANICAL MEANS Depth upto 3m

926.1

59270

64

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. In ordinary soil [MoRTH Specification : clause 301] BY MECHANICAL MEANS In Ordinary/Soft rock (not requiring blasting) [MoRTH Specification : Clause 301]

1532.9

144092

94

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. By using concrete mixer With 20mm nominal size aggregate P.C.C. M-20 grade

91.72

397147

4330

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. By using concrete mixer With 20mm nominal size aggregate R.C.C. M-25 grade

872.6

4183244

4794

... More
Providing and laying steel reinforcement at any level in foundation complete as per drawing and technical specification. [MoRTH Specification : Section 1600]. HYSD bar reinforcement

81.24

7234422

89050

... More
Structural cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification. Design mix concrete – [MoRTH Specification : Section 1500 & 1700]. RCC in M-25 grade, including form work. Upto 5m height

525.97

2738725

5207

... More
Steel reinforcement in substructure complete. [MoRTH Specification : Section 1600] HYSD reinforcement

57.36

5116053

89192

... More
Providing A.C. pipe Weep holes 150mm dia in Masonry/plain Concrete/Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification. [MoRTH Specification : Clause 2205].

896

102144

114

... More
Providing and filling in foundation trenches, and back filling behind abutments, wing walls, return wall etc., and below pipe bed in layers not exceeding 150mm thick including watering and compacting (IRC-78) complete as per drawing and technical specifications (MoRTH specification 710 & 2200) including all lead and lifts. Selected granular Material in filling (MoRTH specification : Clause 2200).

690.09

272585

395

... More
Providing & Laying of Filter media with granular Materials/stone crushed aggregates satisfying (IRC-78) the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. (MoRTH specification : Clause 710, 2200, 2504).

211.33

121514

575

... More
Construction of embankment with approved Material obtained from borrow-pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of Table 300-2 including cost of compensation for earth taken from private land with lead upto 1 km as per MoRTH Specification : Clause No. 305.

255

29835

117

... More
Providing, laying and spreading of granular sub-base by providing coarse graded Material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRTH Specification : clause No. 401. Grading-III

36

11016

306

... More
Providing, laying, spreading and compacting crushed graded stone aggregate as per Table 400-10 & 400.11 to Wet Mix Macadam specifications including premixing the Material with water to OMC in mechanical mixer (Pug mill) as per design mix, carriage of mixed Material by tipper to site laying in uniform layers, with motor grader/F.E. loader/Paver Finisher, in sub-base/base course on a well prepared under-base and compacting with Vibratory Roller to achieve the desired density including lighting, guarding, barricading and maintenance of Driversion etc. (MoRTH specification : Clause 406). with all lead & lift

51.75

63963

1236

... More
Cement Concrete Pavement Construction of un-reinforced, without dowel bar, plain cement concrete pavement, thickness design, over prepared sub base the with 43 Grade Cement or any other type as per Clause 1501.2.2 M30 (Grade) Coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate bit exceeding 25mm, mixed in concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 Micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing) spreading the concrete with shovels rakes, compacted using needle, screed and plate vibrators, adn finished in continous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, near approaches to bridge/ culvert and contruction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound and water finihsing to lines and grade as per drawing and MoRD specification clause 1501 including vaccum dewatering process with all required equipments.

66

358512

5432

... More
Construction of sub-grade and earthen shoulders with approved Material obtained from borrow-pits with all lifts and leads, transporting to site, spreading, grading to require slope and compacted by vibratory roller 8-10 tonne to meet requirement of Table 300-2 as per MoRTH specification : Clause No. 305.

18

1854

103

... More
PART "E" : RETAINING WALL

-

-

-

... More
Earthwork in excavation in foundation trenches etc. in drains and channels etc. not exceeding 2m depth, including dressing of bottom and sides of trenches, stacking the excavated soil 3m clear from the edge of excavation including disposal of surplus soil as directed within a lead of 1000 metres (MoRTH specification : clause 301, 304). Ordinary soil

3951.9

252921

64

... More
Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces

2500

182500

73

... More
Providing A.C. pipe Weep holes 150mm dia in Masonry/plain Concrete/Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification. [MoRTH Specification : Clause 2205].

4935.6

562658

114

... More
Providing cement plaster 12mm thick in Cement mortar 1: 3 at all level ( MoRTH SPECIFICATION : 1000 /1300)

6075

747225

123

... More
Providing and filling in foundation trenches, and back filling behind abutments, wing walls, return wall etc., and below pipe bed in layers not exceeding 150mm thick including watering and compacting (IRC-78) complete as per drawing and technical specifications (MoRTH specification 710 & 2200) including all lead and lifts. Selected granular Material in filling (MoRTH specification : Clause 2200).

337.5

133312

395

... More
Providing & Laying of Filter media with granular Materials/stone crushed aggregates satisfying (IRC-78) the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. (MoRTH specification : Clause 710, 2200, 2504).

135

77625

575

... More
Stone masonry work in cement mortar 1:3 with mechanical mixer for foundation (any level) complete, including all scaffolding etc., excluding pointing and plastering, as per drawing and technical specification. [MoRTH specification : Section 1000, 1400].Random Rubble Masonry (coursed/uncoursed)

6804

21412188

3147

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700].Cement concrete 1:3:6 mix with stone aggregate 40 mm crusher broken.

405

1410210

3482

... More
Providing and laying Plain Cement Concrete M-15 Mix with stone aggregate 20mm nominal size mechanically mixed and vibrated, in superstructure upto 4 meter above 1.50 m level from ground/bed level. [MoRTH Specification : Clause 1000/1700]

81

331776

4096

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. By using concrete mixer With 20mm nominal size aggregate P.C.C. M-20 grade

41.85

181210

4330

... More
Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. By using concrete mixer With 20mm nominal size aggregate R.C.C. M-25 grade

156.6

750740

4794

... More
Structural cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification. Design mix concrete – [MoRTH Specification : Section 1500 & 1700]. RCC in M-25 grade, including form work. Upto 5m height

243

1265301

5207

... More
Providing and laying steel reinforcement at any level in foundation complete as per drawing and technical specification. [MoRTH Specification : Section 1600]. HYSD bar reinforcement

12.29

1094424

89050

... More
Steel reinforcement in substructure complete. [MoRTH Specification : Section 1600] HYSD reinforcement

19.08

1701783

89192

... More
PART "F" : DRAIN WORK

-

-

-

... More
Earthwork in excavation in foundation trenches etc. in drains and channels etc. not exceeding 2m depth, including dressing of bottom and sides of trenches, stacking the excavated soil 3m clear from the edge of excavation including disposal of surplus soil as directed within a lead of 1000 metres (MoRTH specification : clause 301, 304).Ordinary soil

1200

85200

71

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700].Cement concrete 1:3:6 mix with stone aggregate 40 mm crusher broken.

144

501408

3482

... More
Providing and laying RCC M-20 mix with stone aggregate 20mm (nominal size) mechanically mixed and vibrated for RCC work in slab in superstructure upto 4 mtr. above 1.5 mtr. level from Bed/Ground level, excluding steel reinforcement but including centering and shuttering, laid in position. (MoRTH specification : Clause 1000/1700)

336

1662864

4949

... More
Providing and laying Plain Cement Concrete M-15 Mix with stone aggregate 20mm nominal size mechanically mixed and vibrated, in superstructure upto 4 meter above 1.50 m level from ground/bed level. [MoRTH Specification : Clause 1000/1700]

40

163840

4096

... More
Providing and fabricating Steel reinforcement for RCC works including cutting, bending, placing in position and binding complete including cost of binding wire. (MoRTH specification : Clause 1000/1600). HYSD bars

11.76

1047522

89075



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.