Public Works Department Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 66,000Document Cost
₹ 500Tender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEPWD_431053_1Tender No
NIT_13_2024_25_EE_PWD_ED_UdrTender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://pwd.rajasthan.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
( c ) Traction Media: main hoist flat coated steel belt / rope. Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.
-
-
-
(d) Car: car should be with M S platform with bracings of adquate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel with Anti skid PVC flooring and side panels should be of Stainless steel with monorock finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts. Car panel will also be of SS 304 grade finished with emergency stop device , emergency alarm,mechanical door safety device ,full length infra-red curtain in car door, facility of auto/attended mode All car panel buttons and all floor switches must be with brail language as per lift act. Agency shall also make provision for install one no CCTV Camera in the car complete with connecting cables & accessories ( To be connected with existing CCTV system in Building, cost of camera provided by department). The inspection unit shall be provided at the top of the car.
-
-
-
(e) Landing Doors: All landing door shall be fully automatic full length and width centre opening/telescopic opening made of monorock finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside.
-
-
-
(f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided.
-
-
-
(g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR.
-
-
-
(h) Audio-Visual Indication : Audio visual indication in the lift car , showing over loading such that doors kept open till excess load is removed.
-
-
-
(i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors.
-
-
-
(j) Buffers: Spring buffers/PU Buffers shall be provided.
-
-
-
(k) Car Fan: ENERGY EFFICIENT Car fan/blower with automatlc sleep timer be provided.
-
-
-
(I) Voice Annunciator: Voice annunciator with suitable music shall be provided in the lift car
-
-
-
(m) Self diagnostics system for operational and safety parameters shall be provided in control panel
-
-
-
(n) Mechanical/Electronic over speed governor, door key holes in the floor doors,fireman switch shall be provided.
-
-
-
(0) Lift machine hoisting arrangement in the lift(MRL) , counter balance to promote smooth and economic operation complete with steel guide rails for the car &counter weight , Trap Door, Lifting hooks as required and monkey ladders for lift pit should be provided by the agency along with all other steel structure works ,foundations for the machine etc as required .
-
-
-
(p) Agency has to provide all working drawings and Document to comply latest BIS Specifications and make proper liasion service for obtaining all necessary permissions.
-
-
-
Stretcher elevator , 15 passenger, 1020 kg, 2 stops, MRL, rated speed adjustable up to 1.0 mtr/sec
1
1698300
1698300
Supplying,installation,Testing and commissioning of 10 Passenger (MRL) Elevator with 3 stops speed 1.0M/s having following main features from (a) to (p) mentioned below and all as per pre approved by Engineer in charge.For additional technical parameters of products/ work,refer Annexure "A" attached with P.W.D.Electrical
B.S.R. 2022.
-
-
-
(a)MOTOR : Gearless(MRL) lift drive comprising of high starting torque lift duty, 3 phase, 440Volts, A.C. permanent magnetic synchronous motor of proper rating with high efficiency, shall be used.
-
-
-
(b) Operation / Drive : Microcessor based/PLC, AC Variable Voltage variable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response , UP/Down hall stops , main, Up/Down contactor with overload and phase reversal relay and safety controls.
-
-
-
( c ) Traction Media: main hoist flat coated steel belt / rope. Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.
-
-
-
(d) Car: car should be with M S platform with bracings of adquate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel with Anti skid PVC flooring/stone flooring and side panels should be of Stainless steel with monorock finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the car shall be taken as per available lift well size and relevant BIS code of lifts. Car panel will also be of SS 304 grade finished with emergency stop device , emergency alarm,mechanical door safety device ,full length infra-red curtain in car door, facility of auto/attended mode All car panel buttons and all floor switches must be with brail language as per lift act. Agency shall also make provision for install one no CCTV Camera in the car complete with connecting cables & accessories ( To be connected with existing CCTV system in Building, cost of camera provided by department). The inspection unit shall be provided at the top of the car.
-
-
-
(e)Landing Doors: All landing door shall be fully automatic full length and width centre opening/telescopic maximum width opening as per suitable to shaft size & according to goods lift made of monorock finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside.
-
-
-
(f) Emergency light: Appropriate rechargeable battery operated LED emergency light in the car and along with alarm switch shall be provided.
-
-
-
(g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR.
-
-
-
(h) Audio-Visual Indication : Audio visual indication in the lift car , showing over loading such that doors kept open till excess load is removed.
-
-
-
(i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors.
-
-
-
(j) Buffers: Spring buffers/PU Buffers shall be provided.
-
-
-
(k) Car Fan: ENERGY EFFICIENT Car fan/blower with automatlc sleep timer be provided.
-
-
-
(I) Voice Annunciator: Voice annunciator with suitable music shall be provided in the lift car
-
-
-
(m) Self diagnostics system for operational and safety parameters shall be provided in control panel
-
-
-
(n) Mechanical/Electronic over speed governor, door key holes in the floor doors,fireman switch shall be provided.
-
-
-
(0) Lift machine hoisting arrangement in the lift(MRL) , counter balance to promote smooth and economic operation complete with steel guide rails for the car &counter weight , Trap Door, Lifting hooks as required and monkey ladders for lift pit should be provided by the agency along with all other steel structure works ,foundations for the machine etc as required .
-
-
-
(p) Agency has to provide all working drawings and Document to comply latest BIS Specifications and make proper liasion service for obtaining all necessary permissions.
-
-
-
10 Passenger,680 kg, 3 stops,MRL, rated speed adjustable upto 1.0m/s
1
1470000
1470000
Rewiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
Medium point (up to 6 mtr.)
7
472
3304
Long point (up to 10 mtr.)
6
662
3972
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
20 mm
200
40
8000
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
2 x 2.5 sq. mm. + 1x1.5sqmm
120
81
9720
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
Single pole MCB (With B/C curve tripping Characteristics)
-
-
-
6 A to 32 A rating
10
187
1870
Four pole MCB (With B/C curve tripping Characteristics)
-
-
-
50/63 A rating
2
1745
3490
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
Four pole 100/300 mA sensitivity
-
-
-
40 A rating
2
2762
5524
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
Metal door (single phase) IK-09 and IP-43 with Metal end box
-
-
-
12 Way (12+2)
2
2590
5180
Rewiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
On board
15
136
2040
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity 99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
-
-
-
16.0 Sq. mm
-
-
-
4 core
200
232
46400
Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
4
5733
22932
Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity 95% thimble etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
8 SWG G.I. ( Hot Dipped ) Wire
120
20
2400
Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
300 mm sweep
2
1822
3644
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
1170mm(+/-10%) LED batten with min. lumen output 2200 lm
5
492
2460
Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head type light fixture made from Pressure Die Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output , THD 10% ,p.f.≥0.95,CRI 80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
-
-
-
Minimum lumen output 1000 lm
6
1647
9882
Please read Tender - Document and Annexures I , II, and III
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%