Public Works Department Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date8 Oct 2024
Closing Date22 Oct 2024
Tender Amount₹ 43,68,000 
Notes
Download

Costs

  • EMD

    ₹ 87,360
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 500

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

67.5

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

45.94

-

1

... More
Total

169.62

225086

1327

... More
Providing & laying mechanically mixed and vibrated Cement Concrete in foundation upto a depth of 1.5mtr, below ground level and 1.5mtr. above ground/bed level. [MoRTH Specification : Clause 1000/1700]. (a) Cement concrete 1:3:6 mix with crushed stone aggregate 20 mm nominal size.

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

28.13

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

63.83

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

27

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

30.63

-

1

... More
Total

149.58

569282

3806

... More
Providing and Laying un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or Fix form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip,, tie rod, admixtures and vacuum processing pump as approved, , finishing to lines and grades as per drawing as per MoRTH Specification : Clause No. 602, 112. Using Cement concrete M-30 pavement Grade

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

33.75

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

38.75

-

1

... More
Total

72.5

357208

4927

... More
Providing & laying Random Rubble Masonry in cement sand mortar 1:3 in foundation upto a depth of 1.50m and also 1.50m above ground/bed level. [MoRTH Specification : Clause 1000/1400]

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

57.6

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

30.38

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

14.63

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

28.13

-

1

... More
Total

130.73

471656

3608

... More
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock pilling at designated locations and disposal of dismantled Materials upto a lead of 1000 mtrs. stacking serviceable and unserviceable Materials separately. (MoRTH specification : Clause 202)

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

42.75

-

1

... More
Total

42.75

31892

746

... More
Earthwork in excavation for foundation of structure complete with all lift, dewatering, shoring and shuttering etc. including refilling of trenches in 250 mm layer, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical Earth in excavation for foundation of specification. [MoRTH Specification : Clause 304]. In ordinary soil [MoRTH Specification : clause 301] BY MECHANICAL MEANS Depth upto 3m

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

67.5

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

162

-

1

... More
Total

229.5

16983

74

... More
Providing and laying Plain Cement Concrete M-15 mix with stone aggregate 20mm nominal size mechanically mixed and vibrated in foundation upto a depth of 1.50 below ground level and or 1.50mtr. above ground/bed level.

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

21.38

-

1

... More
Total

21.38

94392

4416

... More
Providing and laying RCC M-20 mix with stone aggregate 20mm (nominal size) mechanically mixed and vibrated for RCC work in slab in superstructure upto 4 mtr. above 1.5 mtr. level from Bed/Ground level, excluding steel reinforcement but including centering and shuttering, laid in position. (MoRTH specification : Clause 1000/1700)

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

11.52

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

7.68

-

1

... More
Total

19.2

99898

5203

... More
Providing cement pointing 1:2, Flush & Ruled on stone, brickwork, floor at all levels. (MoRTH Specification : clause 1000/1300).

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

100

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

1500

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

220

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

100

-

1

... More
Total

1920

105600

55

... More
Coursed stone paving set in CM 1:5 Ratio over a bed of 20 mm thick cement morter 1:5 with cement pointing in CM 1:3 200 to 225 mm thick

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

75

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

577.5

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

75

-

1

... More
Total

727.5

571088

785

... More
Reinforced cement concrete wearing coat M-30 grade at any level including formwork and reinforcement complete as per drawing and technical Specification. [MoRTH Specification : Clause 2204, 1500 & 1700].

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

11.25

-

1

... More
Total

11.25

125865

11188

... More
Providing and Laying PCC M-15 grade leveling course below approach slab complete as per drawing and technical specifications. [MoRTH specification : 2700]

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

9

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

3.75

-

1

... More
Total

12.75

47902

3757

... More
Reinforced cement concrete M-30 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications. [MoRTH specification : 1500, 1600, 1700, 2704]

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 7@00

12

-

1

... More
Total

12

111108

9259

... More
Providing and laying Coursed Rubble stone masonry in cement sand mortar 1:3, in superstructure upto a height of 4 meters or part thereof above 1.50m from ground/Bed level. [MoRTH Specification : Clause 1000/1400].

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

2.03

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

22.5

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

17.33

-

1

... More
Total

41.85

160453

3834

... More
Providing cement plaster 20mm thick in cement mortar 1:3 at all levels (MORTH specification : clause 1000/1300)

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

200

-

1

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

225

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

48

-

1

... More
Total

473

70004

148

... More
Back filling behind abutment, wing wall and return wall, in 150mm layers, with mechanical compaction, complete with all lead and lift, as per drawing and technical specification. [MoRTH Specification : Clause 304]. Gravelly Material

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

25

-

1

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

45

-

1

... More
Total

70

31640

452

... More
Providing, laying and spreading of granular sub-base by providing coarse graded Material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRTH Specification : clause No. 401. Grading-III

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 17@00 ls 18@00

45

-

1

... More
Total

45

23535

523

... More
Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 1000 mm dia

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

22.5

-

1

... More
Total

22.5

118373

5261

... More
Dry lean cement concrete sub - base. Construction of dry lean cement concrete 1:3:6 sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blening to be as per Table 600-1, cement content not to be less than 200 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing.

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

67.5

-

1

... More
Total

67.5

213233

3159

... More
Providing and Laying un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub-base with 43 grade cement, coarse and fine aggregate conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or Fix form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures and vacuum processing pump as approved, curing compound, finishing to lines and grades as per drawing as per MoRTH Specification : Clause No. 602, 112. Using Cement concrete M-30 pavement Grade

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

135

-

1

... More
Total

135

793935

5881

... More
Brick masonry work in cement mortar 1:3 for substructure complete, with scaffolding, excluding pointing and plastering, as per drawing and technical specification. [MoRTH Specification : Section 1300].

-

-

-

... More
fd'kuxat ctjaxx+ tyokM+k jksM+ fd-eh- 18@00 ls 18@200

48.15

-

1

... More
Total

48.15

207238

4304

... More
Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 1200 mm dia

-

-

-

... More
jkeiqfj;k ls fcyklx+ fd-eh- 6@00 ls 6@200

10

-

1

... More
Total

10

66070

6607



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.